P i P e S y S t e m S
Suitable for buildingS and houSeS
EleganceraingutterS
CONTENTS
Elegance -FEaTurES & advantageS
22 features & application
3 elegance advantage
aCCErEdiTaTiON& StandardS
6 6 Quality&Certification
7 Standards&Qualification
Elegance -Product detail
7 7 raingutter & fittings
13 rainwater Pipes
14 Paling Solvent cement
iNSTallaTiON
8 18 installation guidelines
26 Project references1abOuT uS
7 27 about Paling industries
27 about aliaxis2
FEaTurES• Anexclusivelayout,withinternalbracketsandoutlets
thatcanbeplacedanywherealongthelengthofthegutter,avoidingtheneedtobreaktherunninglengthforthedownpipe
• Superioroutlook
• CertifiedBSEN607andBSEN1462
adVaNTaGES• CorrosionandUVResistant
• DurableandLightweight
• HighFlowCapacitywith16,100mm2
• NoOverFlow
• Anti-DrippingSystemtoPreventLeak
• WeirOutlettoInduceHigherFlowrate
• Designedtoaccommodateextensivethermalmovement
aPPliCaTiONPaling raingutter Systems are recommended forbuildingapplications,andarespecificallydesignedforcontemporaryhousesandcondominiums.
raiNGuTTErSProduct range
Stylish designTheuniquedesignofthePaling’s
Elegance rainwater gutter
System is able to complement any
contemporarylifestyletodate.With
thisexclusivelayout,theinternal
bracketsandoutletscanbeplaced
anywherealongthelengthofthe
gutterwithouttheneedtobreakthe
runninglengthtoaccommodatethe
down-pipe.
AcomprehensiverangeofPaling’s
Elegance and accessories are
manufacturedtothesamehigh
standards.Paling’sElegance range is
designed to suit wide application and
withitsaestheticallysuperioroutlook,
mostbuildingscanbenefitfromit.
2
ElEGaNCE raiNGuTTErS /// FEaTurES adVaNTaGES
Performance CharacteristicsPVC-Uisacorrosionfreematerial.Itcanwithstandtoughweatherconditionsforanextensiveperiodoftime.ItisUVresistant
eventhoughexposedtodirectsunlight.Itisalsoextremelydurable,lightweightandeasy-to-install.
PVC-Uismaintenancefree.Itssmoothsurfacepreventsalgaeandfungusgrowth.Together,theseinnovativefeatures
improvethebuilding’soutlook,reduceassemblyandinstallationtime,reducepercentageoffailureandhelpsaveupa
considerable amount of money.
Asaresult,thissystemofferseasierandfasterassembly,adesignthatlastmuchlongerthananytypicalrainwatergutter
system.
EfficiencyPaling’sEleganceGutterProfilehasahighcapacitywithaneffectivecrosssectionalareaof16100mm2. it prevents over
flowandkeepsthehousecleananddry.
Theexpansionoutlethashighflowcapacityandantidrippingfeature.Norubbergasketandsolventcementisrequired.In
addition,advancedesignatjointspreventsleakage.
Paling’sElegancecomplieswiththeStandardBSSEN607forgutterprofileandfittingsandStandardBSEN1462forthegutter
brackets.
Elegancerainwater gutter System
3
FEaTurES adVaNTaGES /// ElEGaNCE raiNGuTTErS
4
Paling gutter Profile
MoreflexibilitywithP-Shapefrontreturn
Groovedprofiletoenablehorizontalmovement
afterlockingintointernalbracket
Highercapacity16100mm2
exPanSion outlet
Weirflow,drainingupto6L/Sto10L/S
Noleakingwithantidrippingbaffle
Suitable for round and rectangular
ElEGaNCE raiNGuTTErS /// adVaNTaGES
5
Paling internal bracket
AllowinghorizontalmovementwithP.Shape
Canloadupto60kgeach
Aestheticallysuperioroutlook
Paling exPanSion joiner
Accommodatesthermalmovementfrom-10°c-40°c
2in1(Joiner+expansion)
Doublerubbersealstopreventleakages
adVaNTaGES /// ElEGaNCE raiNGuTTErS
6
RAINWATERGUTTER
RAINWATERGUTTERFITTINGS
RAINWATERDOWNPIPES
1. UnplasticizedPolyvinylChloride(PVC-U)rainwater gutter
1. UnplasticisedPolyvinylChloride(PVC-U)fittingsforRainwaterGutteranddownpipes
For updated copies of our certificates, please visit the Paling website www.paling.com.my
1. UnplasticisedPolyvinylChloride(PVC-U)rainwater downpipes round and rectangularshape
bSENdiN
qualiTy & CErTiFiCaTiON
SySTEm CErTiFiCaTiON
ElEGaNCE raiNGuTTErS /// aCCrEdiTaTiON
7
STaNdardS aNd qualiFiCaTiON
BSEN607forgutterprofileandfittings
BSEN1462forgutterbracket
gutter Profile Printinga Theword‘Paling’orPaling
logo
b Theword‘ELEGANCE’
C ThewordSIRIMCERTIFIEDor
mS logo
d Sirim license number
E Standard conformance
and year of standard
F manufacturing date
G Manufacturingshiftcode
DOWNPIPEFITTINGS1 RoundStraightCoupler
2 round downpipe clip
3 round downpipe
4 RoundBend112°
5 RectangularBend112°
6 rectangular downpipe clip
7 rectangular downpipe
8 RectangularOffset88°
9 RectangularStraightCoupler
gutter fittingSmarkingH Product name
i Paling logo
J Production date
6
7
8
9
STaNdardS & qualiFiCaTiON /// ElEGaNCE raiNGuTTErS
8
STOP ENdCOdE NO. dirECTiON
milKy WHiTE
TrENdyGrEy
2705205LE01 2705205LE22 left
2705205RI01 2705205RI22 right
COdE NO. dimENSiONS(mm)
lENGTH(m)
milKy WHiTE
TrENdy GrEy
a b C
15002055801 15002055822 205 125 424 5.8
GuTTEr PrOFilE
A
B
C
ExPaNSiON OuTlET
COdE NO. OuTlET SiZE
(mm)
SHaPE dimENSiONS
(mm)
milKy WHiTE
TrENdyGrEy
a b
271011001 271011022 110 round 341 238
271011501 271011522 110 rectangular 341 238a
b
iNTErNal COrNEr
COdE NO. dimENSiONS (mm)
milKy WHiTE
TrENdy GrEy
a b
270320501 270320522 227 227
a
b
ElEGaNCE raiNGuTTErS /// ElEGaNCE raiNGuTTEr SySTEm
9
ExTErNal COrNErCOdE NO. dimENSiONS (mm)
milKy WHiTE
TrENdy GrEy
a b
270220501 270220522 227 227
ExPaNSiON JOiNErCOdE NO.
milKyWHiTE
TrENdy GrEy
270920501 270920522
JOiNErCOdE NO.
milKyWHiTE
TrENdy GrEy
270620501 270620522
iNTErNal braCKETCOdE NO.
milKyWHiTE
TrENdy GrEy
270720501 270720522
A
B
ElEGaNCE raiNGuTTEr SySTEm /// ElEGaNCE raiNGuTTErS
10
GraTiNG COdE NO.
milKy WHiTE TrENdy GrEy
270820501 270820522
COdE NO. dimENSiONS (mm)
l l1 l2 d d1
271411501 52 50 122 115 90
STraiGHT COuPlEr (Rectangular)
L1L
D1
D
L2
68° bENd (Rectangular)
COdE NO. aNGlE dimENSiONS (mm)
Ѳ l l1 d d1
271311501 68º 52 50 115 90
D D1
L
L1
ElEGaNCE raiNGuTTErS /// ElEGaNCE raiNGuTTEr SySTEm
11
88° bENd (Rectangular)
COdE NO. aNGlE dimENSiONS (mm)
Ѳ l l1 d d1
271111501 88º 52 50 115 90
D D1
L
L1
OFFSET 88° (Rectangular)
COdE NO. aNGlE dimENSiONS (mm)
Ѳ l l1 d d1
271211501 88º 52 50 115 90
D D1
L
L1
dOWNPiPE CliP (Rectangular)
COdE NO. dimENSiONS (mm)
d d1
270411501 115 90
D
D1
ElEGaNCE raiNGuTTEr SySTEm /// ElEGaNCE raiNGuTTErS
12
rECTaNGulardOWNPiPE
COdE NO. lENGTH(m)
miN.Wall THiCKNESS e (mm)
dimENSiONS(mm)
d d1
15101155801 5.8 1.7 115 90
D
D1
dOWNPiPE CliP (ROUND)
COdE NO. dimENSiONS (mm)
d
270111001 110
D
ElEGaNCE raiNGuTTErS /// ElEGaNCE raiNGuTTEr SySTEm
13
raiNWaTEr PiPES
There are three types of rainwater pipe:
• TheNormalDutyPipeisintendedforexposedinstallationonthebuildingthatdonotexceed
fivestoreysinheight,suchasterracehousesorlow-riseshop-houses.
• TheMediumDutyisintendedforexposedinstallationonbuildingexceedingfivestoreys
• TheHeavyDutydesignedwithhigherringstiffnessforuseinpipeworktobeencasedin
reinforcedconcrete(RC)columns.
D
L
e
COdE NO. mOdEl NOm. SiZE
SPECiFiCaTiON OuTSidE diamETEr
Wall THiCKNESS
lENGTHl
(mm) d(mm) e (mm) (m)
122011058ND01 normal duty 110 BS4576/BSEN12200 110.0-110.3 2.2-2.7 5.8
122011058MD01 medium duty 110 BSEN1329 110.0-110.3 3.2-3.8 5.8
122211058HD20 heavy duty 110 BSEN12200/DIN8061 110.0-110.3 6.0-6.8 5.8
raiNWaTEr dOWNPiPES /// ElEGaNCE raiNGuTTErS
14
COdE NO. dESCriPTiON GimS TiN/CarTON
6050070P Paling clearsolve fast dry 500 20
6010070 Paling clearsolve fast dry 100 60
6050010 Paling coloursolve slow dry
(Blue)
500 20
6050012 Paling clearsolve fast dry
(Green)
500 20
6050011 elegance solvent cement
(rainwatergutter)
500 20
SOlVENT CEmENT
ElEGaNCE raiNGuTTErS /// SOlVENT CEmENT
15
FEaTurES• PVCSolventCementFastDry–forpipesandfittings
≤80mm
• PVCSolventCementSlowDry–forpipesandfittings ≥80mm
• Moderatesolventodour
• ComplieswithMS628orBS4346.SPANlisted
adVaNTaGES• ColourCo-PolymerforEasierApplicationand
inspection
• EasytoUse
• PremiumQuality
• FastandSlowDryingSolventavailableforStrongbonding
aPPliCaTiONPaling Solvent cement is formulated for Pvc pipes used for rainwater and raingutter applications.
SOlVENTcement
Product range
SOlVENT CEmENT /// ElEGaNCE raiNGuTTErS
16
Solid Content: 24%Consistency property: 1,000 pcsquality: Tough & resilientSolid consist of: mEK & CyCColour: GreenStandard: mS628 Part ii Section 2.2
- HighlysolublefastdryPVC-USolventcement.
- SuitableforjoiningallPVC-Upipesfrom15mm-75mm
diameter.
- Whenapplied,itwillinstantlydissolveandblendwiththe
pipetoproduceafilm(wall)of0.4mmthick,sothatthe
fittinggapwillbestrongandstable.
STraiNiNG TimE
Pipes with diameters 15mm 10 seconds
Pipes with diameters 25mm to 32mm 8 seconds
Pipes with diameters 50mm 6 seconds
Pipes with diameters 75mm 4 seconds
PaliNG COlOurSOlVE FaST dry
PaliNG raiNGuTTErS SOlVENT CEmENT
PaliNG COlOurSOlVE SlOW dry
Solid Content: 24%Consistency property: 1,000 pcsquality: Tough & resilientSolid consist of: mEK, CyC & THFColour: blueStandard: mS628 Part ii Section 2.2
- HighlysoluablefastdryPVC-USolventcement.
- SuitableforjoiningallPVC-Upipesfrom75mm-200mm
diameter.
- Whenapplied,itwillinstantlydissolveandblendwiththe
pipetoproduceafilm(wall)of0.4mmthick,sothatthe
fittinggapwillbestrongandstable.
STraiNiNG TimE
Pipes with diameters 25mm 20 seconds
Pipes with diameters 32mm to 50mm 16 seconds
Pipes with diameters 75mm to 100mm 12 seconds
Pipes with diameters 150mm 8 seconds
Pipes with diameters 200mm 4 seconds
Solid Content: 24%Consistency property: 1,000 pcsquality: Tough & resilientSolid consist of: mEK, CyC & THFColour: Transparent and ClearStandard: mS628 Part ii Section 2.2
- SuitableforjoiningallPVC-Upipesraingutter.
- Whenapplied,itwillinstantlydissolveandblendwiththe
pipetoproduceafilm(wall)of0.4mmthick,sothatthe
fittinggapwillbestrongandstable.
STraiNiNG TimE
Gutter Profile 30 seconds
aTTENTiON:
1. Temperaturebelow15°C(50°F)willextendthe
strainingperiodforapproximately5minutesfor
eachtypeofpipe.
2. Alltheabovesolventcementisnotapplicable
tothosePVC-Upipeorfittingwhicharemade
of partly recycled material.
3. Afterassembly,thepipemustbetightlyheld
inplaceandshallonlybereleasedafter
recommended straining time as stipulated. if
releaseprematurely,thepipetobefittedwill
spring apart.
PaCKiNG CTN. SiZE
500g.(withbrush)x20Tinsperctn. 508mmx220mmx225mm
ElEGaNCE raiNGuTTErS /// raiNWaTEr dOWNPiPES
17
NOmiNal SiZE OF PiPE Or FiTTiNG
amOuNT OF SOlVENT CEmENT rEquirEd PEr JOiNT
NO OFPOSSiblE JOiNTS
(mm) (g) 100 g 500 g15 1.3 76 383
20 2.0 55 250
25 2.5 40 200
32 3.2 30 156
40 5.0 20 100
50 7.2 13 69
80 12.0 8 41
100 15.5 6 32
155 26.0 2 19
200 49.0 1 10
SOlVENT CEmENT rEquirEmENT FOr PVC-u PiPES & FiTTiNGS
SOlVENT CEmENT rEquirEmENT FOr PVC-u GuTTErS & COmPONENTS
rECOmmENdaTiONS ON bruSH: PrESSurE TEST:
PHySiCal aNd CHEmiCal PrOPErTiES
SiZE (mm) amOuNT OF SOlVENT CEmENT rEquirEd PEr JOiNT (g) NO OF POSSiblE JOiNTS (500 g)
205x125 15.5 32
A: Pipeswithdiameter25mmandbelow-usebrushas
accompaniedandaffixedtocan
B: Pipeswithdiameter32mmto50mmandbelow
-use1"brush
C: Pipeswithdiameter75mmto200mmandbelow-use
2"brush
D: RainWaterGutterandComponents-usebrushas
accompaniedandaffixedtocan
Flash point: 15°C
Flammable mixture (uN No. 1133)Thissolventcementmaterialwilligniteatambient
temperatures. colourless vapours may travel considerable
distancetoignitionsourcesandcauseflashfiresor
explosions.
Hazard IdentificationMaycauseeyesandskinirritation,burnsordermatitis.
StorageStoreinwell-ventilatedarea.Keepawayfromheat,sparks
andflame.
Safety advice- Keepoutofreachofchildren.
- Keepawayfromsourcesofignition-NoSmoking
- Avoidcontactwitheyes.
- Incaseoffire,usechemicalpowder,foamorcarbon
dioxide.
raiNWaTEr dOWNPiPES /// ElEGaNCE raiNGuTTErS
TEST PrESSurE dryiNG TimE
ColdWater(20°C) Below12kg/cm2(171psi) After1hour
HotWater(60°C) Below12kg/cm2(171psi) After2hours
18
iNSTallaTiON GuidES aNd TiPS
THEFOLLOWINGfactS have to be determined before the iNSTallaTiON StartS
TheEffectiveroofareaThenumberandpositionofoutletsTheanglesandtheirdistancesfromoutletsTotalnumberofbracketsandfittingsLowpointsoftheinstallation (expansionoutletfixingpoint)
Highpointsoftheinstallation
The effective roof areaTheEffectiveRoofArea(ERA)canbedeterminedbyusingthefollowingcalculations:
option Simple calculation formula option multiplication calculation formula
Thetablebelowprovidesawiderrangeoffactorsto
enable accurate assessment of effective roof area to be
determined.TheaverageERAof100m2requiresatleastone
expansionoutlet.Therefore3expansionoutletsareneeded
for example a.
roof pitch Factor
10° 1.088
12.5° 1.111
15° 1.134
17.5° 1.158
20° 1.182
22.5° 1.207
25° 1.233
27° 1.260
30° 1.288
32.5° 1.319
35° 1.350
37.5° 1.384
40° 1,419
42.5° 1.459
45° 1.500
47.5° 1.547
For roofs of 50° and above, a factor of 1.600 may be used
ElEGaNCE raiNGuTTErS /// iNSTallaTiON GuidEliNES
19
iNSTallaTiON GuidES
it is important to read Entire instructions Prior to attempting any installation!
To obtain the maximum benefits, it is essential that you have the right quantity of components and parts before assembling to save time and effort.
required Equipment1.Hammer
2.Hacksaw
3. Power drill
4.Cloth
5.Stringline
6.Builderslevelorlinelevel
7.Ladder
18.Planks
19.Measuringtape
10.Pencil
11.Graphpaper
12Squareandrule
13.Screws
14.Elegance Solvent cement
STEP 1Measureanduseaplanningguidetosketcharoofplan(1centimetre=1metre).
Determinethefittingsrequiredandtransfertheinformationtotheordersheet.
Thiswillenableyoutocalculatethecostofmaterialsrequiredtocompletethe
installation.Also,decidewhereyouwantyourdownpipe.Theeffectiveroofarea
of100m2requiredaminimumofoneexpansionoutlet.Largereffectiveroofarea
willrequiremoreexpansionoutlets.PALING’sEleganceisavailablein4metre
and6metrelengths.
layOuT PlaN ViEW
STEP 2Measuretherooflinewherethegutter
willbeinstalled,addingtogetherthe
lengthsofeachfasciaboard.Takethe
measurementfromtheouteredge
oftheshingle(FigureA).Markthe
measurementsandmakeanoutline
onagraphpaper.
Next,markthelocationsofthe
downpipeswitha‘X’.(FigureB)
Alltherepaintingforthefascia
boardshouldbecompletedbefore
Elegance installation is carried out.
Figure B
iNSTallaTiON GuidEliNES /// ElEGaNCE raiNGuTTErS
20
20mm thickFascia Board
Gutter
STEP 3Driveanailintothefasciaboardatone
endofthegutter-run(FigureC).The
roofeavesbeyondthefasciaboard
shouldbenotbelessthan50mmor
greaterthan75mmtoensurecorrect
roofwaterdischargeintothegutter.
Stretchastringlinefromthenail.To
properlyaligntheslope(usingaline
levelonthestringline)droponeendof
thelineaquarter-inchforevery10feet
offasciaboardlength,thenmarkthat
pointwithapencil(FigureD).
STEP 5Laygutterprofilesandtheirfittings
onthegroundasthemodelforhow
theywillgoonthefasciaboard.Use
hacksawtocutthegutterstothe
requiredlength(FigureG)andremove
allburrsatthecutend.ApplyPALING’s
SolventCementtothejoiningsections
andsealthosesectionsaccordingly
(FigureH).Checktheweldedsections
toensurethattheyarecompletely
sealedtogether.Ensuresufficientsol-
ventcementisusedforjoining.Wipe
offexcesssolventcementwithaclean
clothimmediately.
STEP 4Determinethelowestpoint,and
attachtheexpansionoutlettothe
fascia board by using a power drill
(FigureE).Alongthegutterrun,placed
theinternalbracketsatevery600mm
interval(FigureF).Inordertosupport
thefittings(joiner,internal&external
corner,stopendandexpansion
outlet),internalbracketsshouldbe
fixedatadistanceof150mmfrom
eachendofthefittings
Figure D
Figure C
Figure F
Figure E
Figure H
Figure G
ElEGaNCE raiNGuTTErS /// iNSTallaTiON GuidEliNES
21
STEP 6Toapplythegutterprofilestothe
fasciaboards,positiontheP-shape
interlockoftheguttereachthe
bracketends.Afterensuringeach
bracketiscorrectlyengagedintothe
P-shapeinterlock,rollguttersection
evenlyupwardstowardsthebracket
untilthereartopedgefirmlylocksinto
thebracket(FigureI).Neversolvent
weldthegutterwiththeexpansion
outletsasthegutterneedstomove
freelytoaccommodatethermal
expansion(FigureJ).
STEP 7Aseriesofselectionfittingsare
assembledtodiverttherainwater
tothedrainagesystem.Installpipe
clipsatevery1.8mintervalalongthe
downpipes(FigureK&L).
iNSTallaTiON GuidES
PaliNG’s formulated Solvent Cement to be used with Elegance system. The surface areas to be join must be clean and dry before application. apply solvent cement on both surfaces and join them accordingly. Hold the joining parts together for a minimum of 10 seconds. Check
Theweldedsurfacestoensurethatacompletesealhas
beenachieved.Excesssolventcementontheexterior
surfaceshouldberemovedimmediately.
(NootherSolventCementshouldbeusedwithout
consultationwiththemanufacturer.)
Figure I
Figure J Figure K
iNSTallaTiON GuidEliNES /// ElEGaNCE raiNGuTTErS
22
aPPliCaTiON SOluTiON
TheEleganceexpansionjoinerisspeciallydesignedforaddressingsubstantialmovementfromthermalexpansion/contractionresultingfrominstallationlongandstraightgutter.
Theapplicationisnormallysuitablefortherunofgutterlengthexceeding6metresandwithoutanyincorporationof
expansion outlet.
Itisalsointendedforguttersrunningalongmultiplecorners,withoutthermalmovementprovision.
Utilizingtheexpansionjoinerinsuchinstallationwillpreventguttersfromwarping,bowinganddislocating,resultinginafairly
straightandneatfinish.
ElEGaNCE raiNGuTTErS /// iNSTallaTiON GuidEliNES
23
PrOPriETy FEaTurES
TheEleganceexpansionjoinerisequippedwithdoubleslidingrubberseal(3),whichaccommodatesandfacilitatesthemovementofthegutters(1),(2).
Thedualsealdesignenhancesreliabilityagainstleakageduringnormalorheavyrainfallrate.
Sealmaterialismadeofresilientanddurabletoweatheringeffect.
Thesealsinsidetheexpansionjoinercanbeeasilycleanedorreplaced,intheeventofdamage,byremovingthe2partsof
theunit(lubricatethegasketwithsilicongreaseaftercleaningorreplacementbeforereassembling).Thecompleteunitis
pre-lubricatedatfactory.
Thejoinerisinherentlymarkedwithtemperaturescaletopreciselypositiongutteraccordingtoambienttemperature(range
-10°Cto40°C)
iNSTallaTiON GuidEliNES /// ElEGaNCE raiNGuTTErS
24
TofixtheEleganceexpansionjoinerissimpleandswift.Thestepsoutlinedbelowguidestheinstallation:
• Setbracketspacingat400mmandplacethejoineratmiddistancebetweenthesebrackets.
• SolventCementthegutterintoonesideoftheExpansionJoinerandinsertintopreviouslyinstalledbrackets.
• Settheexpansionjoinerusingthegraduatedtemperaturemarkedontheinsideofthebaseofthefittingaccordingtothe
temperatureatthetimeoftheinstallation.Itisimportantthatthefittingissetintherightpositionforittofunctioncorrectly.
• Determinethelengthofthenextpieceofgutter.SolventCementthislengthofgutterintotheothersideoftheexpansion
joiner,ensuringthejoinerisstillsetatthecorrecttemperatureposition.
iNSTallaTiON
TECHNiCal daTa
dimENSiONS (mm)
L(Open) 190
L(Close) 145
H1 148
H2 130
W 210
ElEGaNCE raiNGuTTErS /// iNSTallaTiON GuidEliNES
25
-3-aPPly THE SOlVENT
CEmENTApplyadhesiveevenlytobothsidestobematedusingabrushingstrokeparalleltooralongthepipeaxis.Itisrecommendedthata1”brushbeusedtoapplythesolventcement
can tin well before using to ensure homogeneity.
-4-maKE THE JOiNT
Insertpipestraightintothefittingasdeeplyintothefittingsocketaspossiblewithouttwistingandholdinplacefirmly
and steadily for at least ten seconds for fast dry and twenty seconds for Slow dry.
Removeexcesssolventcementwithasoftcloth.Asmallclosedadhesiveringshouldbeclearlyvisibleattheendofthefittingtosignalthatthesufficientadhesivehasbeen
applied.
-5-ClEaN THE ExCESS SOlVENT
CEmENTWhenmakingmultiplejointsonapipingsystem,
anundisturbedrestperiodofatleastfiveminutesisrequiredbeforesecondbondcanbecarriedout.Thisistoavoidstresstothefirstjoint,whichmayweakenits
adhesion.
Wait 24 hours before testing or use
-2-dEGrEaSE THE SPiGOT
aNd SOCKETMarktheinsertiondepthtothepipe
spigot to avoid excessive application andprovidescontrolastowhetherpipehasbeenadequatelyinserted
intothefitting.
Cleanpartstobefusedwithprimingfluidtoensurethatdirtandpossible
slip and release agents are removed for optimal results. Scrape off any discolouredpipelayerduetoUV-
radiation or proper bonding cannot beachieved.
forpipeswithdiametersbetween32to50mmand2”brushforpipeswithdiametersabove50mm.Jointmustbemadewithin2minutesofstarting
application.
-1-CuT & dEburr
Wherenecessary,cutpipetolengthofrightangletoitsaxistomaximizesurfaceforbonding.Useofamitreboxandfinetoothsawis
recommended.
cut surface need to be deburred andchamferedtoaslightbevelto simplify centred insertion and uniformadhesivedistribution
between parts.
aSSEmbly PiPES WiTH SOlVENT CEmENT JOiNTS
iNSTallaTiON GuidEliNES /// ElEGaNCE raiNGuTTErS
26
PrOJECT rEFErENCES
TamaN yarl @ Sri PETaliNGmilKy WHiTE
liNK HOuSE@ KaJaNGlEaTHEr brOWN
adda HEiGHT@ JOHOrTrENdy GrEy
ElEGaNCE raiNGuTTErS /// PrOJECT rEFErENCES
Aliaxisispresentinmorethan40countries.TheGrouphasmorethan100manufacturingandcommercialentitiesandemploysover14,600people.
TheethosoftheGroupallowslocalandglobalknowledgeoftheindustry,regulationsandbuildingpracticestocombineandprovideconsistentlyexcellentcustomerservicetospecifies,consultants,contractors,installersandothers.
THE aliaxiS GrOuP iS a lEadiNG GlObal maNuFaCTurEr aNd diSTribuTOr OF Primary PlaSTiC Fluid HaNdliNG SySTEmS uSEd iN rESidENTial aNd COmmErCial CONSTruCTiON.
THE aliaxiS GrOuPabOuT
iN aSia
malaysia:kuala lumpur
Vietnam:HoChiMinh
india:Bangalore,mumbai & goa
Singapore
China:Beijing,Shanghai&Guangzhou
abOuT
PaliNG iNduSTriES SdN. bHd. WaS ESTabliSHEd iN 1971 TO PrOduCE uPVC PiPES & FiTTiNGS iN malaySia. OVEr THE yEarS iT HaS ExPaNdEd iTS raNGE TO OTHEr SaNiTary PrOduCTS aNd SySTEmS liKE PlaSTiC CiSTErNS aNd OTHEr aCCESSOriES.
PaliNG iNduSTriES
Thesesystemsaresuitableforvariousapplicationsandbuildingtypes,includingdomestic,commercial,industrialandcivilconstructionprojects.Ourproductsareaccuratelydesignedtoconsistentlyexceedtheperformanceaspectsspecifiedunderwidelyrecognizedstandards.
AlongwithISO9001certificationandvariousapprovalsbySIRIMandIKRAM,PalingproductsareaccreditedbyNSF,anauthorityinwaterindustrystandards.
Ourproductsaremanufacturedunderaneffectivesystemofinspection,testing,supervisionandcontrol.
27
abOuT uS /// ElEGaNCE raiNGuTTErS
NOTE : : daTE
disclaimer
ThisbrochurehasbeencompiledbyPalingIndustriesSdnBhd(“thecompany”)topromotebetterunderstandingofthetechnicalaspectsoftheCompany’s
productstoassistusersinobtainingfromthemthebestpossibleperformance.Thebrochureissuppliedsubjecttoacknowledgmentofthefollowing
conditions:
i) ThebrochureisprotectedbyCopyrightandmaynotbecopiedorreproducedinanyformorbyanymeansinwholeorinpartwithoutpriorconsentin
writingbytheCompany.
ii) Productspecifications,usagedataandadvisoryinformationmaychangefromtimetotimewithadvancesinresearchandfieldexperience.The
Companyreservestherighttomakesuchchangesatanytimewithoutnotice.
iii) CorrectusageoftheCompany’sproductsinvolveengineeringjudgementswhichcannotbeproperlymadewithoutfullknowledgeofalltheconditions
pertainingtoeachspecificinstallation.TheCompanyexpresslydisclaimsallandanyliabilitytoanypersondonebyanysuchpersoninreliancewhether
wholeorpartialuponthewholeoranypartofthecontentsofthisbrochure.
iv) Nooffertotrade,noranyconditionsoftrading,areexpressedorimpliedbytheissueorcontentofthisbrochure.
v) NothinghereinshalloverridetheCompany’sconditionsofSale,whichmaybeobtainedfromtheRegisteredOfficeoranySalesOfficeoftheCompany.
vi) ThisbrochureisandshallremainthepropertyoftheCompany,andshallsurrenderedondemandtotheCompany.
P i P e S y S t e m SSUITABLEFORBUILDINGS,
houSeS and civil conStruction PurPoSeS.
SOIL ,WASTE&vent
P r e S S u r eP i P i n g S y S t e m
P i P e S y S t e m SSUITABLEFORBUILDINGS,
houSeS and civil conStruction PurPoSeS.
P i P e S y S t e m SSUITABLEFORBUILDINGS,
houSeS and civil conStruction PurPoSeS.
hydrotechtm
mS3MU L T I - L Ay E R P V C - U
undergrounddrainage &SEWER
SyStem
P i P e S y S t e m SSUITABLEFORBUILDINGS,
houSeS and civil conStruction PurPoSeS.
rainWATERdrainage SyStem
P i P e S y S t e m SSUITABLEFORBUILDINGS,
houSeS and civil conStruction PurPoSeS.
P i P e S y S t e m SSuitable for civil
conStruction PurPoSeS and buildingS.
r a i nWATERSyStem & gyrojoint
Lot12,JalanPerusahaan4,68100BatuCaves,SelangorDarulEhsan,malaysia.
T :603-61898333(General) 603-61896389(Sales)
F :603-61883810
distributed by :
PaliNG iNduSTriES SdN bHd (11039 V)
w w w . p a l i n g . c o m . m y
TRUSTED PIPEWORK FOR LIFE