Ordering Information
7210080 ENDOBUTTON™ CL BTB (20mm)
7210081 ENDOBUTTON CL BTB (25mm)
7210082 ENDOBUTTON CL BTB (30mm)
7210083 ENDOBUTTON CL BTB (35mm)
7210084 ENDOBUTTON CL BTB (40mm)
7210085 ENDOBUTTON CL BTB (45mm)
7210086 ENDOBUTTON CL BTB (50mm)
7210087 ENDOBUTTON CL BTB (55mm)
7210088 ENDOBUTTON CL BTB (60mm)
72200839 CL Device (25mm)
72200840 CL Device (30mm)
72200841 CL Device (35mm)
72200842 CL Device (40 mm)
72200843 CL Device (45 mm)
72200844 CL Device (50 mm)
72200134 XTENDOBUTTON fixation device
Ordering Information
7209352 ENDOBUTTON CL Fixation Device 15 mm, sterile, single use
7207323 ENDOBUTTON CL Fixation Device 20 mm, sterile, single use
7207324 ENDOBUTTON CL Fixation Device 25 mm, sterile, single use
7207325 ENDOBUTTON CL Fixation Device 30 mm, sterile, single use
7207326 ENDOBUTTON CL Fixation Device 35 mm, sterile, single use
7207327 ENDOBUTTON CL Fixation Device 40 mm, sterile, single use
7207328 ENDOBUTTON CL Fixation Device 45 mm, sterile, single use
7207329 ENDOBUTTON CL Fixation Device 50 mm, sterile, single use
7209353 ENDOBUTTON CL Fixation Device 55 mm, sterile, single use
7209354 ENDOBUTTON CL Fixation Device 60 mm, sterile, single use
7207315 Cannulated Drill 4.5 mm
7209216 ENDOBUTTON CL Pac
ENDOBUTTON CL Pac includes:
ENDOBUTTON CL sizing calculator
7207315 Cannulated Endoscopic Drill, 4.5 mm
014396 2.4 mm x 10" Drill-Tip Guide Wire
014508 2.7 mm x 15" Drill-Tip Passing Pin
014477 Cannulated Bone Tunnel Plug
Simple fixation solutions for even themost difficult ACL procedures
ENDOBUTTON™ Family of Fixation Devices
ENDOBUTTON™ CL
Consistent cortical fixation–provides strong, dependablefixation regardless of cancellous bone quality
Adaptable–multiple loop sizes accommodate various graftlengths
Unique–ENDOBUTTON CL is the preferred fixation devicefor use with double tunnel techniques
Mechanical Properties of Soft Tissue Femoral FixationDevices for Anterior Cruciate Ligament Reconstruction
Christopher S. Ahmad, MD*, Thomas R. Gardner, ME, Megan Groh, JohnnyArnouk and William N. Levine, MD
From the Center for Shoulder, Elbow, and Sports Medicine, Department
of Orthopaedic Surgery, Columbia University, New York, New York
Since it was introduced in the early 90s, the ENDOBUTTONFixation Device and its associated technique have become thepreferred choice for femoral fixation for surgeons who performanatomic anterior cruciate ligament reconstruction. Thanks tothe product’s simple design that incorporates a continuousloop of suture, adopting the ENDOBUTTON surgical techniqueis effortless.
The recently introduced CL and XTENDOBUTTON™ Fixation Devices were developed to expand the
capabilities of ENDOBUTTON. As a result, the ENDOBUTTON family now provides a complete line
of femoral fixation solutions to meet any patient requirement. Best of all, every device delivers the
added benefit of hassle-free endoscopic ACL revision surgeries.
CL Device
Incorporates knotless design–offersENDOBUTTON CL fixation strength in apost- or screw-and-washer technique
Gets more graft in the tunnel–allows fora larger portion of graft to reside in thetunnel
Adaptable–available in six sizes, from 25mm to 50 mm
ENDOBUTTON™ CL BTB
Strong–provides dependable fixationfor bone-tendon-bone reconstructionprocedures
Eliminates complications–preventsscrew divergence, tendon graftlaceration and posterior blowout
Removes the need for knot tying–minimizes elongation of construct
XTENDOBUTTON™
Covers a 6 to 10 mm area of thefemoral tunnel–provides an effectivesolution to cortical blowouts
Reduces surgical time–proceduresonly require one primary drill for theentire distance of the femoral tunnel
Low profile fixation for pediatriccases–outside-in drilling to avoidgrowth plates is now possible,eliminating the need for a washer andresulting in a lower profile fixation
ENDOBUTTON CL
Bottom
Top side2 Pull the button all the
way through 1 From the bottom of the
XTENDOBUTTON insertthe ENDOBUTTON devicethrough center hole
3 Pull back on the graftor loop to seat withinthe XTENDOBUTTON