In order to realiseanalysis of RX of quality,
only is necessary to obtain a good pellet. That procedure is easy
with a good press.
Pellet must satisfy two requirements, must be stable and reproducible.
![Page 4: Equilab Pellet Press Eqp 100 english](https://reader033.vdocument.in/reader033/viewer/2022052318/58e8486c1a28ab4b158b6029/html5/thumbnails/4.jpg)
EQP-100Equilab Press
![Page 5: Equilab Pellet Press Eqp 100 english](https://reader033.vdocument.in/reader033/viewer/2022052318/58e8486c1a28ab4b158b6029/html5/thumbnails/5.jpg)
In order to make analysis of RX of quality the pellets must have a suitable pressing providing the most smoothest possible surface.
![Page 6: Equilab Pellet Press Eqp 100 english](https://reader033.vdocument.in/reader033/viewer/2022052318/58e8486c1a28ab4b158b6029/html5/thumbnails/6.jpg)
The correct pressing of the pellets allows that X-rays can refract of appropriate way, sending to the receiver of rx representative
information of the sample to analyze.
![Page 7: Equilab Pellet Press Eqp 100 english](https://reader033.vdocument.in/reader033/viewer/2022052318/58e8486c1a28ab4b158b6029/html5/thumbnails/7.jpg)
Considerationsto prepare
pellets
![Page 8: Equilab Pellet Press Eqp 100 english](https://reader033.vdocument.in/reader033/viewer/2022052318/58e8486c1a28ab4b158b6029/html5/thumbnails/8.jpg)
cohesitive - dwell time - pellet cups
![Page 9: Equilab Pellet Press Eqp 100 english](https://reader033.vdocument.in/reader033/viewer/2022052318/58e8486c1a28ab4b158b6029/html5/thumbnails/9.jpg)
FORCE
![Page 10: Equilab Pellet Press Eqp 100 english](https://reader033.vdocument.in/reader033/viewer/2022052318/58e8486c1a28ab4b158b6029/html5/thumbnails/10.jpg)
to obtain reproducible pelletsalways the same force must be applied.
![Page 11: Equilab Pellet Press Eqp 100 english](https://reader033.vdocument.in/reader033/viewer/2022052318/58e8486c1a28ab4b158b6029/html5/thumbnails/11.jpg)
PARTICLES SIZE
LOW
The presence of voids between particles affect the emited energy in XR instrument.Recomended particles size:
> 200µ150 / 100µ
HIGH
![Page 12: Equilab Pellet Press Eqp 100 english](https://reader033.vdocument.in/reader033/viewer/2022052318/58e8486c1a28ab4b158b6029/html5/thumbnails/12.jpg)
EQR – 100Equilab Vibratory Mill
Simple handlingSafe, fast and noiseless
5 work programs
![Page 13: Equilab Pellet Press Eqp 100 english](https://reader033.vdocument.in/reader033/viewer/2022052318/58e8486c1a28ab4b158b6029/html5/thumbnails/13.jpg)
GAS OCLUSSIONS
Certain types of substances are noted to outgas and collect into pockets or fill any prexisting voids in between the sample particles. If the gas is not allowed to diffuse under briquetting pressure it is
reduced in size and potentially pressurized. During decompression, any entraped gas tends to abruptly expand and create fissures on the sample surface in the process, or even mildly explode when
subject to analysis in an evacuated environment.
Press EQP-100 is specially designed to help us to obtain the best results in the elaboration of our pellets. Of a robust and extremely
resistant design it is functionally simple and very effective, and is the unique one of the market that offers up to five programs of work with a simple or double cycle. This alternative allows us to program the press so that it applies pressure until in two occasions in a same
process, offering us the possibility of digitally regulating the time and the pressure, and the lapse of time passed between each pressed
cycle, this time is necessary, in some cases, so that the sample can bleed occluided gases. These gases are, generally, the causes of
irregularities or fissures in the tablets.
![Page 14: Equilab Pellet Press Eqp 100 english](https://reader033.vdocument.in/reader033/viewer/2022052318/58e8486c1a28ab4b158b6029/html5/thumbnails/14.jpg)
MOISTURE ON SAMPLE
Atention:
Samples must be dry before realising the pressing. The effect produced by a moisture in the sample is similar to the
generated by ocludded gases - appearance of cracks or breakage in the surface -.
![Page 15: Equilab Pellet Press Eqp 100 english](https://reader033.vdocument.in/reader033/viewer/2022052318/58e8486c1a28ab4b158b6029/html5/thumbnails/15.jpg)
![Page 16: Equilab Pellet Press Eqp 100 english](https://reader033.vdocument.in/reader033/viewer/2022052318/58e8486c1a28ab4b158b6029/html5/thumbnails/16.jpg)
![Page 17: Equilab Pellet Press Eqp 100 english](https://reader033.vdocument.in/reader033/viewer/2022052318/58e8486c1a28ab4b158b6029/html5/thumbnails/17.jpg)
![Page 18: Equilab Pellet Press Eqp 100 english](https://reader033.vdocument.in/reader033/viewer/2022052318/58e8486c1a28ab4b158b6029/html5/thumbnails/18.jpg)
Each element emits a characteristic fluorescent radiation.
![Page 19: Equilab Pellet Press Eqp 100 english](https://reader033.vdocument.in/reader033/viewer/2022052318/58e8486c1a28ab4b158b6029/html5/thumbnails/19.jpg)
SOLUTIONS
- Pellets cups. Cups facilitate the compaction preventing the segregation of the sample- Pressing double cycle. Facilitates the occluded gas elimination.- Drying of the sample. Moisture elimination (105ºC).
ADDITIVES- Stearic acid (wax). The wax usually is the more used
binder. Obtaining a good result with the majority of the samples. Usually is mixed with the sample during the process of milling in a proportion among 10 and 20%.
- Boric acid. Is very resistant to the heat and very abrasive. It is used mainly with samples that have tendency to be fused during the milling process. Usually it is mixed with the sample during the process of milling in a proportion among 10 and 20%.
- Elvacite. Polymer that allows to make very stable samples across the time.
![Page 20: Equilab Pellet Press Eqp 100 english](https://reader033.vdocument.in/reader033/viewer/2022052318/58e8486c1a28ab4b158b6029/html5/thumbnails/20.jpg)
Equilab Press EQP-100 can process all type of samples, from very low to high levels of hardness.
Control speed frequency variator 0/200 HzPower suply 2 x 220 V 50/60 Hz
Control of programs 5 Programs (Microprocessor)Protection IP 40
Diameter Sample 30-40 mm(Other sizes under demand)
Diameter of the Piston 120mmEngine power 750wCaudal 1,17 l/ min
Maximun pressure of work 540 bar/cm
![Page 21: Equilab Pellet Press Eqp 100 english](https://reader033.vdocument.in/reader033/viewer/2022052318/58e8486c1a28ab4b158b6029/html5/thumbnails/21.jpg)
Equilab Press EQP 100
VIEWS
![Page 22: Equilab Pellet Press Eqp 100 english](https://reader033.vdocument.in/reader033/viewer/2022052318/58e8486c1a28ab4b158b6029/html5/thumbnails/22.jpg)
DIMENSIONS
Approx weight 75 Kgs
![Page 23: Equilab Pellet Press Eqp 100 english](https://reader033.vdocument.in/reader033/viewer/2022052318/58e8486c1a28ab4b158b6029/html5/thumbnails/23.jpg)
OPERATION
![Page 24: Equilab Pellet Press Eqp 100 english](https://reader033.vdocument.in/reader033/viewer/2022052318/58e8486c1a28ab4b158b6029/html5/thumbnails/24.jpg)
![Page 25: Equilab Pellet Press Eqp 100 english](https://reader033.vdocument.in/reader033/viewer/2022052318/58e8486c1a28ab4b158b6029/html5/thumbnails/25.jpg)
Five programs simple or
double cycle
![Page 26: Equilab Pellet Press Eqp 100 english](https://reader033.vdocument.in/reader033/viewer/2022052318/58e8486c1a28ab4b158b6029/html5/thumbnails/26.jpg)
Language selectSpanish
![Page 27: Equilab Pellet Press Eqp 100 english](https://reader033.vdocument.in/reader033/viewer/2022052318/58e8486c1a28ab4b158b6029/html5/thumbnails/27.jpg)
Language selectEnglish
![Page 28: Equilab Pellet Press Eqp 100 english](https://reader033.vdocument.in/reader033/viewer/2022052318/58e8486c1a28ab4b158b6029/html5/thumbnails/28.jpg)
• Default values• Speed control
![Page 29: Equilab Pellet Press Eqp 100 english](https://reader033.vdocument.in/reader033/viewer/2022052318/58e8486c1a28ab4b158b6029/html5/thumbnails/29.jpg)
• First step
![Page 30: Equilab Pellet Press Eqp 100 english](https://reader033.vdocument.in/reader033/viewer/2022052318/58e8486c1a28ab4b158b6029/html5/thumbnails/30.jpg)
• Sample
![Page 31: Equilab Pellet Press Eqp 100 english](https://reader033.vdocument.in/reader033/viewer/2022052318/58e8486c1a28ab4b158b6029/html5/thumbnails/31.jpg)
• Adding wax
![Page 32: Equilab Pellet Press Eqp 100 english](https://reader033.vdocument.in/reader033/viewer/2022052318/58e8486c1a28ab4b158b6029/html5/thumbnails/32.jpg)
• Mixing
![Page 33: Equilab Pellet Press Eqp 100 english](https://reader033.vdocument.in/reader033/viewer/2022052318/58e8486c1a28ab4b158b6029/html5/thumbnails/33.jpg)
• Mixing
![Page 34: Equilab Pellet Press Eqp 100 english](https://reader033.vdocument.in/reader033/viewer/2022052318/58e8486c1a28ab4b158b6029/html5/thumbnails/34.jpg)
• Sample on a cup
![Page 35: Equilab Pellet Press Eqp 100 english](https://reader033.vdocument.in/reader033/viewer/2022052318/58e8486c1a28ab4b158b6029/html5/thumbnails/35.jpg)
• Placing sample and start
![Page 36: Equilab Pellet Press Eqp 100 english](https://reader033.vdocument.in/reader033/viewer/2022052318/58e8486c1a28ab4b158b6029/html5/thumbnails/36.jpg)
• Working
![Page 37: Equilab Pellet Press Eqp 100 english](https://reader033.vdocument.in/reader033/viewer/2022052318/58e8486c1a28ab4b158b6029/html5/thumbnails/37.jpg)
• Working
![Page 38: Equilab Pellet Press Eqp 100 english](https://reader033.vdocument.in/reader033/viewer/2022052318/58e8486c1a28ab4b158b6029/html5/thumbnails/38.jpg)
• Manually spindle down
![Page 39: Equilab Pellet Press Eqp 100 english](https://reader033.vdocument.in/reader033/viewer/2022052318/58e8486c1a28ab4b158b6029/html5/thumbnails/39.jpg)
• Working
![Page 40: Equilab Pellet Press Eqp 100 english](https://reader033.vdocument.in/reader033/viewer/2022052318/58e8486c1a28ab4b158b6029/html5/thumbnails/40.jpg)
• Dwell time
![Page 41: Equilab Pellet Press Eqp 100 english](https://reader033.vdocument.in/reader033/viewer/2022052318/58e8486c1a28ab4b158b6029/html5/thumbnails/41.jpg)
• Depressing
![Page 42: Equilab Pellet Press Eqp 100 english](https://reader033.vdocument.in/reader033/viewer/2022052318/58e8486c1a28ab4b158b6029/html5/thumbnails/42.jpg)
• Manually spindle up
![Page 43: Equilab Pellet Press Eqp 100 english](https://reader033.vdocument.in/reader033/viewer/2022052318/58e8486c1a28ab4b158b6029/html5/thumbnails/43.jpg)
• Sample up!!
![Page 44: Equilab Pellet Press Eqp 100 english](https://reader033.vdocument.in/reader033/viewer/2022052318/58e8486c1a28ab4b158b6029/html5/thumbnails/44.jpg)
• Extract the sample
![Page 45: Equilab Pellet Press Eqp 100 english](https://reader033.vdocument.in/reader033/viewer/2022052318/58e8486c1a28ab4b158b6029/html5/thumbnails/45.jpg)
• Sample ready!!
![Page 46: Equilab Pellet Press Eqp 100 english](https://reader033.vdocument.in/reader033/viewer/2022052318/58e8486c1a28ab4b158b6029/html5/thumbnails/46.jpg)
![Page 47: Equilab Pellet Press Eqp 100 english](https://reader033.vdocument.in/reader033/viewer/2022052318/58e8486c1a28ab4b158b6029/html5/thumbnails/47.jpg)
ADVANTAGES
• User friendliness.
• Compact design.
• Automatic adjustment.
• Regulation of pressure of 5 to 40T (possibility of reaching to 60T).
• 5 programs (simple or double cycle).
• Manual functions.
• Speed Control.
• Mold including in the system (it does not need DIE).