Flad Architects Page 1 of 2 Flad Code Forum Notes : 11 February 2016
Flad Code Forum Notes 11 February 2016 1. Code Forums
a. Notes of past code forums are posted at : i. Flad Home Page / Resources / Codes / Forums / Year / Date of Forum.
b. Next Code Forum: 02/25/16 : Bldg Code Provisions for Fire & Smoke Compartments c. This Code Forum will Discuss : Evaluating the Accessibility of a Building d. Additional information is contained in attached power point slides: PP-pages.
Evaluating the Accessibility of a Building – Refer to PP-01 through PP-65 2. Codes & Standards: PP-03 - PP-14
a. Federal : 2010 ADA Standards for Accessible Design (“Standards”) b. State (IBC Reference) : ICC A117.1-2009 (“A117”)
i. State or local provisions take precedence over Federal law when their requirements are more stringent.
ii. Dept of Justice (DOJ) has certified the following state’s accessibility requirements as being equivalent to the “Standards.” (1) Maryland (2) North Carolina (3) Washington (4) Texas (5) Maine (6) Florida (7) Indiana (8) California (9) Utah (10) Michigan (11) New Jersey
c. Standards i. Full compliance with the Standards is required only for new construction and
alterations. ii. Barrier removal requirement for existing facilities is new under the Standards and
supersedes less stringent local or state codes. iii. Includes safe harbor under which those elements in facilities built or altered in
compliance with the 1991 Standards are not required to be brought into compliance with the 2010 Standards until those elements are scheduled for alterations.
iv. Includes “exceptions” of areas that are not required to be accessible. d. A117
i. Full compliance with A117.1 is required new construction, alterations and existing buildings.
ii. (46) “Existing” references e. Terminology : the correct term is "disability“ C a “person with a disability.” f. Process : Plans, survey, document.
3. Accessible approach and entrance: PP-15 - PP-30 a. Route of Travel (RT)
i. Includes arrival to the site, approach to the building, and entrance into the building. ii. RT cannot include stairs, must be stable, and be 36” wide (min)
b. Ramps i. Running slope greater than 1:20 (min) but not steeper 1:12 ii. Example
![Page 2: Evaluating the Accessibility of a Building](https://reader034.vdocument.in/reader034/viewer/2022042723/587c05901a28ab03768b4583/html5/thumbnails/2.jpg)
Flad Architects Page 2 of 2 Flad Code Forum Notes : 11 February 2016
iii. 1:20 = Rise : Run (1) 1 : 20 = 30” : Run, Run = 30” x 20 = 600” = 50’-0”
(a) Every 30” of rise, required to have a 5’ long landing (b) 50’ (Run) + 5’ (Landing) = 55’ Total
c. Parking and Drop-Off Areas i. Accessible Parking Spaces (APS) : closest to the accessible entrance ii. Parking Facilities include surface lots and parking structures
d. Entrance i. Entrances are categorized per the following :
(1) Public Entrance (PE) (2) Service Entrance (SE) (3) Restricted Entrance (RE)
ii. Minimum number of accessible PEs changed from 50% (1991 Standards) to 60% (Standards).
4. Access to goods and services: PP-31 - PP-45 a. Horizontal Circulation
i. Accessible entrance must provide direct access to the main floor, lobby, or elevator. ii. Accessible routes must be 36” minimum and provide areas to reverse direction iii. Accessible routes less than 60” shall provide passing spaces every 200’ max. iv. Accessible routes must be to ALL public spaces
(1) Example (Flad - MSN) : includes numerous conference rooms on all levels that should all be accessible (see dark red filled spaces on PP-38).
b. Accessible spaces that require more than (1) Means of Egress must be provided with at least (2) accessible Means of Egress i. Example (Flad - MSN) : In addition to the central stairway, at least (1) of the end
stairways must be on an accessible route (see light red filled spaces on PP-41). c. Doors : 32” clear opening (minimum), Pull/Push side clearances d. Rooms & Spaces : Aisles/Pathways 36” clear (minimum)
5. Access to rest rooms : PP-46 - PP-51 a. If a non-accessible toilet room is on an accessible route, a sign indicating the nearest
accessible toilet room is required. 6. Any other measures necessary: PP-52 - PP-53 7. Employee Work Areas: PP-54 - PP-65
a. Spaces used only by employees and used only for work i. Corridors, toilet rooms, kitchenettes and break rooms are not employee work areas.
b. Individuals with disabilities can approach, enter, and exit the employee work area. c. Exceptions for Employee Work Areas (EWA)
i. Modular office furniture ii. Stairs/walkways as part of a piece of equipment (e.g. electric turbines)
d. Changes to EWA Access i. 1991 Standard : Maneuvering within the work area or to be accessible. ii. 2010 Standards : Requires that common use circulation paths inside employee work
areas greater than 1,000 square feet be accessible. e. Common Use Areas (CUA) : corridors, toilet rooms, kitchenettes and break rooms
i. All CUAs are required to be accessible T:\twyatt\Code\Code Forums\2016 0211\2016 0211 Code Forum Notes.docx
![Page 3: Evaluating the Accessibility of a Building](https://reader034.vdocument.in/reader034/viewer/2022042723/587c05901a28ab03768b4583/html5/thumbnails/3.jpg)
F L A D C O D E F O R U M
Evaluating the Accessibility of a Building
02/11/2016 Flad Code Forum 1
![Page 4: Evaluating the Accessibility of a Building](https://reader034.vdocument.in/reader034/viewer/2022042723/587c05901a28ab03768b4583/html5/thumbnails/4.jpg)
O U T L I N E
• Codes & Standards
• Process
• Priorities
– P1 : Accessible approach and entrance
– P2 : Access to goods and services
– P3 : Access to rest rooms
– P4 : Any other measures necessary
02/11/2016 Flad Code Forum 2
![Page 5: Evaluating the Accessibility of a Building](https://reader034.vdocument.in/reader034/viewer/2022042723/587c05901a28ab03768b4583/html5/thumbnails/5.jpg)
Codes & Standards
02/11/2016 Flad Code Forum 3
![Page 6: Evaluating the Accessibility of a Building](https://reader034.vdocument.in/reader034/viewer/2022042723/587c05901a28ab03768b4583/html5/thumbnails/6.jpg)
02/11/2016 Flad Code Forum 4
![Page 7: Evaluating the Accessibility of a Building](https://reader034.vdocument.in/reader034/viewer/2022042723/587c05901a28ab03768b4583/html5/thumbnails/7.jpg)
ADA Standards for Accessible Design
• Full compliance with the Standards is required
only for new construction and alterations
• Each state has its own regulations regarding
accessibility
• Use the more stringent technical requirement
• Barrier removal requirement for existing
facilities is new under the ADA and
supersedes less stringent local or state codes.
02/11/2016 Flad Code Forum 5
![Page 8: Evaluating the Accessibility of a Building](https://reader034.vdocument.in/reader034/viewer/2022042723/587c05901a28ab03768b4583/html5/thumbnails/8.jpg)
ADA Standards for Accessible Design
• The new regulations include a general safe harbor under which those elements in facilities built or altered in compliance with the 1991 Standards are not required to be brought into compliance with the 2010 Standards until those elements are scheduled for alterations.
02/11/2016 Flad Code Forum 6
![Page 9: Evaluating the Accessibility of a Building](https://reader034.vdocument.in/reader034/viewer/2022042723/587c05901a28ab03768b4583/html5/thumbnails/9.jpg)
General Exceptions
• 203.2 Construction Sites
• 203.3 Raised Areas– Prison guard towers, fire towers, or life guard stands
• 203.4 Limited Access Spaces– Spaces accessed only by ladders & catwalks
• 203.5 Machinery Spaces– Spaces frequented only by service personnel (elevator pit)
• 203.6 Single Occupant Structures– Toll booths accessed only by underground tunnels
• 203.7 Detention and Correctional Facilities– Common use areas not serving holding cells or housing cells
02/11/2016 Flad Code Forum 7
![Page 10: Evaluating the Accessibility of a Building](https://reader034.vdocument.in/reader034/viewer/2022042723/587c05901a28ab03768b4583/html5/thumbnails/10.jpg)
General Exceptions
• 203.8 Residential Facilities– Common use areas not serving units required to provide
mobility features
• 203.9 Employee Work Areas– Individuals with disabilities can approach, enter, and exit the
employee work area
• 203.10 Raised Refereeing, Judging, and Scoring Areas
• 203.11 Water Slides
• 203.12 Animal Containment Areas– Public circulation routes where animals may travel (e.g. petting
zoos) are not eligible for the exception.
• 203.13 Raised Boxing or Wrestling Rings
• 203.14 Raised Diving Boards and Diving Platforms
02/11/2016 Flad Code Forum 8
![Page 11: Evaluating the Accessibility of a Building](https://reader034.vdocument.in/reader034/viewer/2022042723/587c05901a28ab03768b4583/html5/thumbnails/11.jpg)
ANSI - A117.1
• Chapter 2. Scoping
– 201 General This standard provides technical criteria for making sites, facilities, buildings, and elements accessible … These scoping provisions shall address the application of this standard to: each building and occupancy type; new construction, alterations, temporary facilities, and existing buildings; specific site and building elements; and to multiple elements or spaces provided within a site or building.
• “Existing” = (46) references– 308.3 Side Reach. Existing elements that are not altered
shall be permitted at 54 inches (1370 mm) maximum above the floor.
02/11/2016 Flad Code Forum 9
![Page 12: Evaluating the Accessibility of a Building](https://reader034.vdocument.in/reader034/viewer/2022042723/587c05901a28ab03768b4583/html5/thumbnails/12.jpg)
ANSI - A117.1 : Existing References
• 308.3 Side Reach
• 404.2.4 Thresholds
• 405 Ramps : 405.2 Slope
• 407 Elevators– 407.2.1 Call Controls
– 407.2.1.5 Signals
– 407.2.2.1 Visible and Audible Signals
– 407.2.2.2 Visible Signals
– 407.2.2.3 Audible Signals
– 407.3 Elevator Door Requirements• 407.3.2 Operation.
• 407.3.3 Reopening Device
• 407.3.6 Width
– 407.4 Elevator Car Requirements• 407.4.1 Inside Dimensions
• 407.4.6 Elevator Car Controls
• 407.4.7 Designations and Indicators of Car Controls
– 408.4 Elevator Car Requirements
• 410 Platform Lifts – 410.5.2 Lifts with Doors on Adjacent
Sides
• 608 Shower Compartments – 608.6 Thresholds
• 805 Transportation Facilities – 805.5 Rail Platforms
– 805.9 Escalators
• 1002 Accessible Units – 1002.5 Doors and Doorways
• 1103 Recreational Boating Facilities– 1103.3.1 Boat Slip Clearance
• 1108 Play Areas
02/11/2016 Flad Code Forum 10
![Page 13: Evaluating the Accessibility of a Building](https://reader034.vdocument.in/reader034/viewer/2022042723/587c05901a28ab03768b4583/html5/thumbnails/13.jpg)
Terminology
• Disabled or handicapped?– A disability is the result of a medically definable condition that
limits a person's movements, senses, or activities.
– A handicap is a barrier or circumstance that makes progress or success difficult, such as an impassable flight of stairs or a negative attitude toward a person who has a disability.
• The correct term is "disability“ … a person with a disability. – Person-first terminology is used because the person is more
important than his or her disability.
• Accessible means in compliance with the Federal accessibility guidelines and standards. – Accessible sites and facilities do not contain barriers limiting
their use by people with disabilities.
02/11/2016 Flad Code Forum 11
![Page 14: Evaluating the Accessibility of a Building](https://reader034.vdocument.in/reader034/viewer/2022042723/587c05901a28ab03768b4583/html5/thumbnails/14.jpg)
Process
02/11/2016 Flad Code Forum 12
![Page 15: Evaluating the Accessibility of a Building](https://reader034.vdocument.in/reader034/viewer/2022042723/587c05901a28ab03768b4583/html5/thumbnails/15.jpg)
Process
• Obtain Floor & Site Plans
• Conduct the Survey– 2 Surveyors : 1 takes notes, Both take measurements
– Consider people with physical, hearing, visual, and cognitive disabilities
• Summarize Barriers and Solutions
• Make Decisions and Set Priorities– Decide which solutions will best eliminate barriers at a
reasonable cost
• Maintain Documentation
• Make Changes– Implement changes as planned
02/11/2016 Flad Code Forum 13
![Page 16: Evaluating the Accessibility of a Building](https://reader034.vdocument.in/reader034/viewer/2022042723/587c05901a28ab03768b4583/html5/thumbnails/16.jpg)
02/11/2016 Flad Code Forum 14
![Page 17: Evaluating the Accessibility of a Building](https://reader034.vdocument.in/reader034/viewer/2022042723/587c05901a28ab03768b4583/html5/thumbnails/17.jpg)
P1 : Accessible approach and entrance
02/11/2016 Flad Code Forum 15
![Page 18: Evaluating the Accessibility of a Building](https://reader034.vdocument.in/reader034/viewer/2022042723/587c05901a28ab03768b4583/html5/thumbnails/18.jpg)
P1 : Accessible approach and entrance
• Route of Travel
• Ramps
• Parking and Drop-Off Areas
• Entrance
02/11/2016 Flad Code Forum 16
![Page 19: Evaluating the Accessibility of a Building](https://reader034.vdocument.in/reader034/viewer/2022042723/587c05901a28ab03768b4583/html5/thumbnails/19.jpg)
P1 : Accessible approach and entrance
• People with disabilities should be able to
– arrive on the site,
– approach the building,
– and enter as freely as everyone else.
• At least one route of travel should be safe and
accessible for everyone, including people with
disabilities.
02/11/2016 Flad Code Forum 17
![Page 20: Evaluating the Accessibility of a Building](https://reader034.vdocument.in/reader034/viewer/2022042723/587c05901a28ab03768b4583/html5/thumbnails/20.jpg)
Route of Travel
• Is there a route of travel that does not require the use of stairs?– Add a ramp or an alternate route on level ground.
• Is the route of travel stable, firm and slip-resistant?– Repair uneven paving.
• Is the route at least 36 inches wide?– Widen route.
• Do curbs on the route have curb cuts at drives, parking, and drop-offs?– Install curb cuts.
02/11/2016 Flad Code Forum 18
![Page 21: Evaluating the Accessibility of a Building](https://reader034.vdocument.in/reader034/viewer/2022042723/587c05901a28ab03768b4583/html5/thumbnails/21.jpg)
Route of Travel
02/11/2016 Flad Code Forum 19
![Page 22: Evaluating the Accessibility of a Building](https://reader034.vdocument.in/reader034/viewer/2022042723/587c05901a28ab03768b4583/html5/thumbnails/22.jpg)
Route of Travel
02/11/2016 Flad Code Forum 20
![Page 23: Evaluating the Accessibility of a Building](https://reader034.vdocument.in/reader034/viewer/2022042723/587c05901a28ab03768b4583/html5/thumbnails/23.jpg)
Ramps
02/11/2016 Flad Code Forum 21
![Page 24: Evaluating the Accessibility of a Building](https://reader034.vdocument.in/reader034/viewer/2022042723/587c05901a28ab03768b4583/html5/thumbnails/24.jpg)
Ramps
02/11/2016 Flad Code Forum 22
78’
180’
![Page 25: Evaluating the Accessibility of a Building](https://reader034.vdocument.in/reader034/viewer/2022042723/587c05901a28ab03768b4583/html5/thumbnails/25.jpg)
Ramps
02/11/2016 Flad Code Forum 23
78’ : X’ = 1 : 20 … X = 20’ x 78’ = 1560’ long ramp (estimate)
Every 2.5’ of Rise = 50’ ramp + 5’ landing = 55’
78’ / 2.5’ = 31.2 … 31.2 x 55’ = 1716’ long ramp (1/3 of a mile)
78’
180’
![Page 26: Evaluating the Accessibility of a Building](https://reader034.vdocument.in/reader034/viewer/2022042723/587c05901a28ab03768b4583/html5/thumbnails/26.jpg)
Parking and Drop-Off Areas
• Location:– IBC: “Accessible parking stalls shall be located on the
shortest route possible to the accessible entrance.” Refer to IBC-09: 1106.6.
– ADA: “Parking spaces … shall be located on the shortest accessible route from parking to an entrance, per ADA 208.3.1. At least 60% of all public entrances (including entrances used by employees that are not service entrances or restricted entrances) are to be accessible, per ADA 206.4.1. • Note : Minimum number of accessible entrances changed from
50% to 60%.
• Example: If there are two public entrances, both would need to be accessible.
02/11/2016 Flad Code Forum 24
![Page 27: Evaluating the Accessibility of a Building](https://reader034.vdocument.in/reader034/viewer/2022042723/587c05901a28ab03768b4583/html5/thumbnails/27.jpg)
Parking and Drop-Off Areas
• Minimum Numbers of Accessible Parking:
– Parking requirements apply to ALL “facilities”, including surface lots and parking structures.
– Each “parking facility” is to provide the required number of spaces based on the numbers of overall parking stalls in each “parking facility.”
02/11/2016 Flad Code Forum 25
![Page 28: Evaluating the Accessibility of a Building](https://reader034.vdocument.in/reader034/viewer/2022042723/587c05901a28ab03768b4583/html5/thumbnails/28.jpg)
Parking and Drop-Off Areas
02/11/2016 Flad Code Forum 26
(135) Parking Spaces = (130) PS + (5) Accessible PS
![Page 29: Evaluating the Accessibility of a Building](https://reader034.vdocument.in/reader034/viewer/2022042723/587c05901a28ab03768b4583/html5/thumbnails/29.jpg)
Parking and Drop-Off Areas
02/11/2016 Flad Code Forum 27
![Page 30: Evaluating the Accessibility of a Building](https://reader034.vdocument.in/reader034/viewer/2022042723/587c05901a28ab03768b4583/html5/thumbnails/30.jpg)
Parking and Drop-Off Areas
02/11/2016 Flad Code Forum 28
(135) + (78) = (213) Total Parking Spaces
(7) Accessible Parking Spaces required = (2) short
![Page 31: Evaluating the Accessibility of a Building](https://reader034.vdocument.in/reader034/viewer/2022042723/587c05901a28ab03768b4583/html5/thumbnails/31.jpg)
Entrances
• Any access point to a building or portion of a building or facility used for the purpose of entering.
• An entrance includes the approach walk, the vertical access leading to the entrance platform, the entrance platform itself, vestibule if provided, the entry door or gate, and the hardware of the entry door or gate.
• Public Entrance (PE)
• Service Entrance (SE)
• Restricted Entrance (RE)
02/11/2016 Flad Code Forum 29
![Page 32: Evaluating the Accessibility of a Building](https://reader034.vdocument.in/reader034/viewer/2022042723/587c05901a28ab03768b4583/html5/thumbnails/32.jpg)
02/11/2016 Flad Code Forum 30
PE
SE
RE
RE
![Page 33: Evaluating the Accessibility of a Building](https://reader034.vdocument.in/reader034/viewer/2022042723/587c05901a28ab03768b4583/html5/thumbnails/33.jpg)
P2: Access to goods and services
02/11/2016 Flad Code Forum 31
![Page 34: Evaluating the Accessibility of a Building](https://reader034.vdocument.in/reader034/viewer/2022042723/587c05901a28ab03768b4583/html5/thumbnails/34.jpg)
P2: Access to goods and services
• Horizontal Circulation
• Doors
• Rooms and Spaces
• Emergency Egress
• Signage for Goods and
Services
• Controls
• Seats, Tables, and
Counters
• Vertical Circulation
• Stairs
• Elevators
• Lifts
02/11/2016 Flad Code Forum 32
![Page 35: Evaluating the Accessibility of a Building](https://reader034.vdocument.in/reader034/viewer/2022042723/587c05901a28ab03768b4583/html5/thumbnails/35.jpg)
Horizontal Circulation
• Does the accessible entrance provide direct access to the main floor, lobby, or elevator?
• Are all public spaces on an accessible route of travel?
• Is the accessible route to all public spaces at least 36 inches wide?
• Is there a 5-foot circle or a T-shaped space for a person using a wheelchair to reverse direction?
02/11/2016 Flad Code Forum 33
![Page 36: Evaluating the Accessibility of a Building](https://reader034.vdocument.in/reader034/viewer/2022042723/587c05901a28ab03768b4583/html5/thumbnails/36.jpg)
Horizontal Circulation
02/11/2016 Flad Code Forum 34
Lobby
Elevator
Main Floor
Public Spaces
![Page 37: Evaluating the Accessibility of a Building](https://reader034.vdocument.in/reader034/viewer/2022042723/587c05901a28ab03768b4583/html5/thumbnails/37.jpg)
Horizontal Circulation
• Does the accessible entrance provide direct access to the main floor, lobby, or elevator?
– YES
• Are ALL public spaces on an accessible route of travel?
– YES
• Is the accessible route to ALL public spaces at least 36 inches wide?
– YES
• Is there a 5-foot circle or a T-shaped space for a person using a wheelchair to reverse direction?
– YES
02/11/2016 Flad Code Forum 35
![Page 38: Evaluating the Accessibility of a Building](https://reader034.vdocument.in/reader034/viewer/2022042723/587c05901a28ab03768b4583/html5/thumbnails/38.jpg)
Horizontal Circulation
02/11/2016 Flad Code Forum 36
Public Toilets
![Page 39: Evaluating the Accessibility of a Building](https://reader034.vdocument.in/reader034/viewer/2022042723/587c05901a28ab03768b4583/html5/thumbnails/39.jpg)
02/11/2016 Flad Code Forum 37
![Page 40: Evaluating the Accessibility of a Building](https://reader034.vdocument.in/reader034/viewer/2022042723/587c05901a28ab03768b4583/html5/thumbnails/40.jpg)
02/11/2016 Flad Code Forum 38
![Page 41: Evaluating the Accessibility of a Building](https://reader034.vdocument.in/reader034/viewer/2022042723/587c05901a28ab03768b4583/html5/thumbnails/41.jpg)
2012 IBC : SECTION 1007
ACCESSIBLE MEANS OF EGRESS
1007.1 Accessible means of egress required.
Accessible means of egress shall comply with this section. Accessible spaces shall be provided with not less than one accessible means of egress. Where more than one means of egress are required by Section 1015.1 or 1021.1 from any accessible space, each accessible portion of the space shall be served by not less than twoaccessible means of egress.
02/11/2016 Flad Code Forum 39
![Page 42: Evaluating the Accessibility of a Building](https://reader034.vdocument.in/reader034/viewer/2022042723/587c05901a28ab03768b4583/html5/thumbnails/42.jpg)
2012 IBC : SECTION 1007
ACCESSIBLE MEANS OF EGRESS1007.2 Continuity and components.
Each required accessible means of egress shall be continuous to a public way and shall consist of one or more of the following components:
1. Accessible routes complying with Section 1104.
2. Interior exit stairways complying with Sections 1007.3 and 1022.
3. Interior exit access stairways complying with Sections 1007.3 and 1009.3.
4. Exterior exit stairways complying with Sections 1007.3 and 1026 and serving levels other than the level of exit discharge.
5. Elevators complying with Section 1007.4.
6. Platform lifts complying with Section 1007.5.
7. Horizontal exits complying with Section 1025.
8. Ramps complying with Section 1010.
9. Areas of refuge complying with Section 1007.6.
10. Exterior area for assisted rescue complying with Section 1007.7.
02/11/2016 Flad Code Forum 40
![Page 43: Evaluating the Accessibility of a Building](https://reader034.vdocument.in/reader034/viewer/2022042723/587c05901a28ab03768b4583/html5/thumbnails/43.jpg)
02/11/2016 Flad Code Forum 41
![Page 44: Evaluating the Accessibility of a Building](https://reader034.vdocument.in/reader034/viewer/2022042723/587c05901a28ab03768b4583/html5/thumbnails/44.jpg)
Doors
• Do doors into public spaces have at least a 32-inch clear opening?
• On the pull side of doors, next to the handle, is there at least 18 inches of clear wall space so that a person using a wheelchair or crutches can get near to open the door?
02/11/2016 Flad Code Forum 42
![Page 45: Evaluating the Accessibility of a Building](https://reader034.vdocument.in/reader034/viewer/2022042723/587c05901a28ab03768b4583/html5/thumbnails/45.jpg)
Doors
• Can doors be openedwithout too much force (5 lbf maximum for interior doors)?
• Are door handles 48 inches high or less and operable with a closed fist?
• Are all threshold edges 1/4-inch high or less, or if beveled edge, no more than 3/4-inch high?
02/11/2016 Flad Code Forum 43
![Page 46: Evaluating the Accessibility of a Building](https://reader034.vdocument.in/reader034/viewer/2022042723/587c05901a28ab03768b4583/html5/thumbnails/46.jpg)
Rooms and Spaces
• Are all aisles and
pathways to materials
and services at least 36
inches wide?
• Is there a 5-foot circle
or T-shaped space for
turning a wheelchair
completely?
02/11/2016 Flad Code Forum 44
![Page 47: Evaluating the Accessibility of a Building](https://reader034.vdocument.in/reader034/viewer/2022042723/587c05901a28ab03768b4583/html5/thumbnails/47.jpg)
Rooms and Spaces
• Are all aisles and
pathways to materials
and services at least 36
inches wide?
• Aisle between library
shelving is less than 36
inches wide.
02/11/2016 Flad Code Forum 45
![Page 48: Evaluating the Accessibility of a Building](https://reader034.vdocument.in/reader034/viewer/2022042723/587c05901a28ab03768b4583/html5/thumbnails/48.jpg)
P3: Access to rest rooms
02/11/2016 Flad Code Forum 46
![Page 49: Evaluating the Accessibility of a Building](https://reader034.vdocument.in/reader034/viewer/2022042723/587c05901a28ab03768b4583/html5/thumbnails/49.jpg)
P3: Access to rest rooms
• Getting to the Rest Rooms
• Doorways and Passages
• Stalls & WCs
• Lavatories
02/11/2016 Flad Code Forum 47
![Page 50: Evaluating the Accessibility of a Building](https://reader034.vdocument.in/reader034/viewer/2022042723/587c05901a28ab03768b4583/html5/thumbnails/50.jpg)
Getting to the Rest Rooms
• If rest rooms are available to the
public, is at least one rest room (either
one for each sex, or unisex) fully
accessible?
– YES
• Are there signs at inaccessible rest
rooms that give directions to
accessible ones?
– NA
02/11/2016 Flad Code Forum 48
![Page 51: Evaluating the Accessibility of a Building](https://reader034.vdocument.in/reader034/viewer/2022042723/587c05901a28ab03768b4583/html5/thumbnails/51.jpg)
Doorways and Passages
• Is there tactile signage identifying rest rooms?
– YES
• Is the doorway at least 32 inches clear?
– YES
• Are doors equipped with accessible handles (operable with a closed fist), 48 inches high or less?
– YES
• Can doors be opened easily (5 lbf maximum force)?
– YES
• Does the entry configuration provide adequate maneuvering space for a person using a wheelchair?
– YES
• Is there a 36-inch-wide path to all fixtures?
– YES
02/11/2016 Flad Code Forum 49
![Page 52: Evaluating the Accessibility of a Building](https://reader034.vdocument.in/reader034/viewer/2022042723/587c05901a28ab03768b4583/html5/thumbnails/52.jpg)
Stalls & WCs
• Is the centerline of the WC no less than 16 inches and no greater than 18 inches from the side wall or partition? YES
• Is clearance provided around the WC measuring at least 60 inches from the side wall and at least 56 inches from the rear wall? YES* (Corner bump-out)
• Is the height of the WC no less than 17 inches and no greater than 19 inches above the floor measured to the top of the seat? YES
02/11/2016 Flad Code Forum 50
![Page 53: Evaluating the Accessibility of a Building](https://reader034.vdocument.in/reader034/viewer/2022042723/587c05901a28ab03768b4583/html5/thumbnails/53.jpg)
Lavatories
• Does at least one lavatory have a clear floor space for a forward approach at least 30 inches wide and 48 inches long? YES
• Is the front of the lavatory or counter surface, whichever is higher, no more than 34 inches above the floor? YES
• Are pipes below the lavatory insulated or otherwise configured to protect against contact? NO
02/11/2016 Flad Code Forum 51
![Page 54: Evaluating the Accessibility of a Building](https://reader034.vdocument.in/reader034/viewer/2022042723/587c05901a28ab03768b4583/html5/thumbnails/54.jpg)
P4: Any other measures necessary
02/11/2016 Flad Code Forum 52
![Page 55: Evaluating the Accessibility of a Building](https://reader034.vdocument.in/reader034/viewer/2022042723/587c05901a28ab03768b4583/html5/thumbnails/55.jpg)
P4: Any other measures necessary
• Drinking Fountains : OK
• Telephones : NA
• Fire Alarm Systems : NA
02/11/2016 Flad Code Forum 53
![Page 56: Evaluating the Accessibility of a Building](https://reader034.vdocument.in/reader034/viewer/2022042723/587c05901a28ab03768b4583/html5/thumbnails/56.jpg)
Employee Work Areas
• Employee Work Area. All or any portion of a space usedonly by employees and used only for work. Corridors, toilet rooms, kitchenettes and break rooms are not employee work areas.
• Work Area Equipment. Any machine, instrument, engine, motor, pump, conveyor, or other apparatus used to perform work. – As used in this document, this term shall apply only to
equipment that is permanently installed or built-in in employee work areas.
– Work area equipment does not include passenger elevators and other accessible means of vertical transportation.
02/11/2016 Flad Code Forum 54
![Page 57: Evaluating the Accessibility of a Building](https://reader034.vdocument.in/reader034/viewer/2022042723/587c05901a28ab03768b4583/html5/thumbnails/57.jpg)
Employee Work Areas
203.9 Employee Work Areas.
Spaces and elements within employee work areas shall only be required to comply with 206.2.8, 207.1, and 215.3 and shall be designed and constructed so that individuals with disabilities can approach, enter, and exit the employee work area.
Employee work areas, or portions of employee work areas, other than raised courtroom stations, that are less than 300 square feet (28 m2) and elevated 7 inches (180 mm) or more above the finish floor or ground where the elevation is essential to the function of the space shall not be required to comply with these requirements or to be on an accessible route.
02/11/2016 Flad Code Forum 55
![Page 58: Evaluating the Accessibility of a Building](https://reader034.vdocument.in/reader034/viewer/2022042723/587c05901a28ab03768b4583/html5/thumbnails/58.jpg)
Employee Work Areas
Advisory 203.9 Employee Work Areas.
Although areas used exclusively by employees for work are not required to be fully accessible, consider designing such areas to include non-required turning spaces, and provide accessible elements whenever possible. Under the ADA, employees with disabilities are entitled to reasonable accommodations in the workplace; accommodations can include alterations to spaces within the facility.
Designing employee work areas to be more accessible at the outset will avoid more costly retrofits when current employees become temporarily or permanently disabled, or when new employees with disabilities are hired.
02/11/2016 Flad Code Forum 56
![Page 59: Evaluating the Accessibility of a Building](https://reader034.vdocument.in/reader034/viewer/2022042723/587c05901a28ab03768b4583/html5/thumbnails/59.jpg)
Employee Work Areas
206.2.8 Employee Work Areas. Common use circulation paths within employee work areas shall comply with 402.
EXCEPTIONS:
1. Common use circulation paths located within employee work areas that are less than 1000 square feet (93 m2) and defined by permanently installed partitions, counters, casework, or furnishings shall not be required to comply with 402.
2. Common use circulation paths located within employee work areas that are an integral component of work area equipment shall not be required to comply with 402.
3. Common use circulation paths located within exterior employee work areas that are fully exposed to the weather shall not be required to comply with 402.
02/11/2016 Flad Code Forum 57
![Page 60: Evaluating the Accessibility of a Building](https://reader034.vdocument.in/reader034/viewer/2022042723/587c05901a28ab03768b4583/html5/thumbnails/60.jpg)
Employee Work Areas
Advisory 206.2.8 Employee Work Areas Exception 1.
Modular furniture that is not permanently installed is not directly subject to these requirements. The Department of Justice ADA regulations provide additional guidance regarding the relationship between these requirements and elements that are not part of the built environment. Additionally, the Equal Employment Opportunity Commission (EEOC) implements title I of the ADA which requires non-discrimination in the workplace. EEOC can provide guidance regarding employers’ obligations to provide reasonable accommodations for employees with disabilities.
Advisory 206.2.8 Employee Work Areas Exception 2.
Large pieces of equipment, such as electric turbines or water pumping apparatus, may have stairs and elevated walkways used for overseeing or monitoring purposes which are physically part of the turbine or pump. However, passenger elevators used for vertical transportation between stories are not considered “work area equipment” as defined in Section 106.5.
02/11/2016 Flad Code Forum 58
![Page 61: Evaluating the Accessibility of a Building](https://reader034.vdocument.in/reader034/viewer/2022042723/587c05901a28ab03768b4583/html5/thumbnails/61.jpg)
Employee Work Areas
1991 Standards
• No accessibility requirements applicable to the interior of an employee work area
• Did not require an employee work area to be constructed to permit maneuvering within the work area or to be accessible.
02/11/2016 Flad Code Forum 59
![Page 62: Evaluating the Accessibility of a Building](https://reader034.vdocument.in/reader034/viewer/2022042723/587c05901a28ab03768b4583/html5/thumbnails/62.jpg)
Employee Work Areas
2010 Standards
• Requires that common use circulation paths insideemployee work areas greater than 1,000 square feet be accessible.
• Existing facilities that already comply with the 1991 Standards and do not make any alterations to their facilities after March 15, 2012, do not need to comply with 2010 Standards.
02/11/2016 Flad Code Forum 60
![Page 63: Evaluating the Accessibility of a Building](https://reader034.vdocument.in/reader034/viewer/2022042723/587c05901a28ab03768b4583/html5/thumbnails/63.jpg)
02/11/2016 Flad Code Forum 61
![Page 64: Evaluating the Accessibility of a Building](https://reader034.vdocument.in/reader034/viewer/2022042723/587c05901a28ab03768b4583/html5/thumbnails/64.jpg)
02/11/2016 Flad Code Forum 62
![Page 65: Evaluating the Accessibility of a Building](https://reader034.vdocument.in/reader034/viewer/2022042723/587c05901a28ab03768b4583/html5/thumbnails/65.jpg)
02/11/2016 Flad Code Forum 63
![Page 66: Evaluating the Accessibility of a Building](https://reader034.vdocument.in/reader034/viewer/2022042723/587c05901a28ab03768b4583/html5/thumbnails/66.jpg)
Work or Common Use Areas ?
02/11/2016 Flad Code Forum 64
![Page 67: Evaluating the Accessibility of a Building](https://reader034.vdocument.in/reader034/viewer/2022042723/587c05901a28ab03768b4583/html5/thumbnails/67.jpg)
F L A D C O D E F O R U M
T H A N K Y O U F O R
AT T E N D I N G
02/11/2016 Flad Code Forum 65
![Page 68: Evaluating the Accessibility of a Building](https://reader034.vdocument.in/reader034/viewer/2022042723/587c05901a28ab03768b4583/html5/thumbnails/68.jpg)
02/11/2016 Flad Code Forum 66