DRAWING CONVENTIONS
N
A
1
View Name1/8" = 1'-0"
1
1A101
LEVEL NAMEELEVATION
1A101
1A101
1A101
A101
A
B
C
D
REFERENCE SYMBOLSIDENTITY SYMBOLS LINE SYMBOLS
CENTER LINE
DEMOLISHED
HIDDEN
OVERHEAD
PROPERTY LINE
1 HOUR RATING
2 HOUR RATING
3 HOUR RATING
4 HOUR RATING
EXIT SEPARATION
1
2' -
0"
2' -
0"
MATCH LINE
126
A401
2
BUILDING SECTION
WALL SECTION
ELEVATION
INTERIOR ELEVATION
EXTERIOR ELEVATION
DIMENSION CONVENTIONS
SLOPE CONVENTION
COLUMN GRID
BLOWUP DETAIL
VIEW INDICATOR
NORTH ARROW
ELEVATION INDICATOR
REVISION CLOUD
# POUND OR NUMBER& AND@ ATA.C.T. ACOUSTICAL CEILING TILEA.F.F ABOVE FINISHED FLOORALUM. ALUMINUMANOD. ANODIZEDAPPROX. APPROXIMATEB.O. BOTTOM OFC.I.P. CAST IN PLACEC.J. CONTROL JOINTCLG. CEILINGCLR. CLEARCMU CONCRETE MASONRY UNITCOL. COLUMNCONC. CONCRETECONT. CONTINUOUSCPT. CARPETC.T. CERAMIC TILEDEMO DEMOLISHDIA. DIAMETERDIM. DIMENSIONDIMS. DIMENSIONSDN. DOWNDR. DOORDWG. DRAWINGEA. EACHELEC. ELECTRICALELEV. ELEVATION OR ELEVATOREPDM ETHYLENE PROPYLENE DIENE M-CLASS (ROOFING)EQ. EQUALEXIST. EXISTINGEXP. JT. EXPANSION JOINTEXT. EXTERIORE.W.C. ELECTRIC WATER COOLERF.D. FLOOR DRAINF.E. FIRE EXTINGUISHERF.E.C. FIRE EXTINGUISHER CABINETFLR. FLOORF.O. FACE OF
GA. GAUGEGALV. GALVANIZEDGYP. GYPSUMGYP. BRD. GYPSUM WALLBOARDH. HIGHH.M. HOLLOW METALHVAC HEATING, VENTILATION, AND AIR CONDITIONINGINSUL. INSULATIONMAX. MAXIMUMM.O. MASONRY OPENINGMECH. MECHANICALMIN. MINIMUMMTL. METALN.I.C. NOT IN CONTRACTNO. NUMBERNOM. NOMINALO.C. ON CENTERO.H. OVERHEADO.P.C.I. OWNER PROVIDED CONTRATOR INSTALLEDOPP. HAND OPPOSITE HANDPLYWD. PLYWOODP.T. PRESSURE TREATEDPVC POLYVINYL CHLORIDER.C.P. REFLECTED CEILING PLANR.D. ROOF DRAINREQD. REQUIREDRM. ROOMSIM. SIMILARSS STAINLESS STEELSTL. STEELSTRUCT. STRUCTURALT TEMPEREDT&G TONGUE AND GROOVETELE. TELEPHONETLT. TOILETT.O. TOP OFT.O.S. TOP OF STEELTYP. TYPICALU.O.N. UNLESS OTHERWISE NOTEDV.I.F. VERIFY IN FIELDW. WIDTHW/ WITHWD. WOOD
ABBREVIATIONS
PROJECT INFORMATIONNAME OF PROJECT:ADDRESS:PROPOSED USE:OWNER OR AUTHORIZED AGENT:OWNED BY:CODE ENFORCEMENT JURISDICTION: OFFICE OF THE STATE ENGINEER
PROJECT DESIGN TEAM
ARCHITECTURAL:CIVIL:STRUCTURAL:PLUMBING:FIRE PROTECTION:MECHANICAL:
STUDIO 2LR, INC.--
DESIGNER FIRM
ELECTRICAL:OTHER:
SPRINKLER-STANDPIPE:
CONTACT
(803) 233-6602
PHONE #
(---) --------
(803) 791-9300(---) --------(803) 791-9300(---) --------(803) 252-6919(---) --------
BUILDING CODE SUMMARY
CODE COMPLIANCEINTERNATIONAL BUILDING CODE:INTERNATIONAL PLUMBING CODE:INTERNATIONAL MECHANICAL CODE:INTERNATIONAL FIRE CODE:NATIONAL ELECTRIC CODE:
ICC/ANSI - 117.1:
2018 EDITION WITH SC MODIFICATIONS2018 EDITION
ADA STANDARDS FOR ACCESSIBLE DESIGN
2018 EDITION2018 EDITION WITH SC MODIFICATIONS2017 EDITION
2017 EDITION
BUILDING DATACONSTRUCTION TYPE (TABLE 503):SPRINKLERS:STANDPIPES:FIRE DISTRICT:BUILDING HEIGHT:MEZZANINE:
IIBNO NON/A
FEETNO
EXIST. 40 NUMBER OF STORIES2 UNLIMITED PER --
HIGH RISE: NO
GROSS BUILDING AREA:FLOOR EXISTING (SQ. FT.)
18,4301ST FLOOR
EXIT REQUIREMENTS
NUMBER AND ARRANGEMENTS OF EXITSEXISTING EXITS TO REMAIN
EXIT WIDTHEXISTING EXIT WIDTH TO REMAIN
PLUMBING FIXTURE REQUIREMENTSEXISTING PLUMBING FIXTURE COUNTS TO REMAIN, REPLACEMENT OF EXISTING FIXTURES AND FINISHES.
--SWYGERT AND ASSOCIATES. LTD.--SWYGERT AND ASSOCIATES, LTD.--GWA ENGINEERING--
----TODD SWYGERT--BILL LIVINGSTON--DICKSON O'BRIEN--
INTERNATIONAL ENERGY CONSERVATION CODE 2009 EDITION
2010 EDITION
(---) --------
2ND FLOOR 21,996
INTERIOR RENOVATIONS FOR ARTS, HUMANITIES, SOCIAL SCIENCES BUILDING
UNIVERSITY OF SOUTH CAROLINA AIKENBRIAN ENTEREXISTING EDUCATION BUILDINGAIKEN, SOUTH CAROLINA
NOTE TO AUTHORITY HAVING JURISDICTION - THIS IS AN INTERIOR RENOVATION OF 4 GANG TOILETS, FINISHES AND FIXTURES.
FIRE RATINGSEXISTING CORRIDORS ARE 1 HOUR FIRE RATED WITH 20 MINUTE RATED DOORS.
SCH
OLAR
LOO
P
SCH
OLAR
LOO
P
SCHOLAR LOOP
SCHOLAR LOOP
UN
IVERSITY PAR
KWAY
N
ARTS, HUMANITIES, & SOCIAL SCIENCES BUILDING
PROJECT NUMBER
DATETHIS
DRA
WIN
G A
ND T
HE D
ESIG
N SH
OW
N TH
EREO
N AR
E PR
OPE
RTY
OF
STUD
IO 2
LR, I
NC.
THE
REPR
ODU
CTIO
N, C
OPY
ING
, OR
OTH
ER U
SE O
F TH
IS D
RAW
ING
WIT
HOUT
WRI
TTEN
CO
NSEN
T O
F ST
UDIO
2LR
, INC
. IS
PRO
HIBI
TED
AND
INFR
ING
EMEN
TS W
ILL
BE S
UBJE
CT T
O L
EGAL
ACT
ION.
STU
DIO
2LR
, IN
C.
24
28
MA
IN S
TR
EE
TC
OLU
MB
IA, S
C2
92
01
P 8
03
.23
3.6
60
2S
TU
DIO
2LR
.CO
M
CLI
EN
T N
AM
E
PR
OJE
CT
NA
ME
LOC
ATI
ON
SHEET NAME
SHEET NUMBER
C DBA
32
1
2/1/
2021
5:0
1:51
PM
20084
01/29/2021
CVR
AH
SS
BLD
G F
IRS
T FL
OO
RR
ES
TRO
OM
RE
NO
VA
TIO
NS
PR
OJE
CT
# H
29-I
364
5000
3418
COVER SHEET
UN
IVE
RS
ITY
OF
SO
UTH
CA
RO
LIN
A A
IKE
N
ISS
UE
D F
OR
BID
DIN
G, J
AN
UA
RY
29,
202
1
AIK
EN
, SO
UTH
CA
RO
LIN
A
DRAWING LIST
SHEET NO. SHEET NAMECURRENTREVISION
CURRENTREVISION
DATE
GENERALCVR COVER SHEET
ARCHITECTURAL DEMOLITIONAD101 DEMOLITION PLANSAD102 ENLARGED DEMOLITION PLANS
ARCHITECTUREA101 FLOOR PLANA110 REFLECTED CEILING PLANA401 ENLARGED PLANS RMS 104 and 105A402 ENLARGED PLANS RMS 115 and 118, DOOR SCHEDA700 FINISH SPECS, FINISH SCHEDULE, FINISH PLANS
PLUMBING DEMOLITIONPD101 DEMOLITION PLANS
PLUMBINGP101 RENOVATION PLANS - WASTE & VENT PIPINGP201 RENOVATION PLANS - SUPPLY PIPINGP301 DETAILS, NOTES, SCHEDULE, & LEGEND
MECHANICAL DEMOLITIONMD101 DEMOLITION PLANS
MECHANICALM101 RENOVATION PLANSM201 DETAILS, NOTES, SCHEDULES, & LEGEND
ELECTRICAL DEMOLITIONED01 ELECTRICAL DEMOLITION PLANS
ELECTRICALE001 ELECTRICAL NOTES, SCHEDULES, AND DETAILSE002 ELECTRICAL NOTES, SCHEDULES, AND DETAILSE100 ELECTRICAL PLANS - NEW WORK
UofSC AIKENFIRST FLOOR RESTROOM RENOVATIONS FOR
ART, HUMANITIES AND SOCIAL SCIENCES BUILDING
Note to Permitting Authority: Studio 2LR, Inc. and their consultants are not under contract with the Owner to provide construction administration services for this project. 1" = 200'-0"2 CAMPUS PLAN
PROJECT # H29-I364 50003418
REVISIONS
NO. DATE DESCRIPTION
AD1021
AD1023
B C D E F G H I J K
1
2
NO WORK THIS AREA
NO WORK THIS AREA
NO WORK THIS AREA
NO WORK THIS AREA
NO WORK THIS AREA
NO WORK THIS AREA
GENERAL DEMOLITION NOTES1. EXISTING CONDITIONS AND DEMOLITION NOTES BASED ON EXISTING DRAWINGS BUT NOT ON AS BUILTS.
GENERAL CONTRACTOR TO FIELD VERIFY CONDITIONS PRIOR TO START OF CONSTRUCTION. IF GENERAL CONTRACTOR DISCOVERS EXISTING CONDITIONS DIFFER FROM THOSE SHOWN, NOTIFY OWNER OR ARCHITECT IMMEDIATELY.
2. GENERAL CONTRACTOR TO PROTECT ALL ADJACENT SURFACES TO REMAIN FROM DAMAGE DURING DEMOLITION. GENERAL CONTRACTOR TO REPAIR/REPLACE ANY ADJACENT SURFACES DAMAGED DURING CONSTRUCTION TO MATCH ORIGINAL CONDITIONS.
SELECTIVE DEMOLITION1. DEMOLISH AND REMOVE EXISTING CONSTRUCTION ONLY TO THE EXTENT REQUIRED BY NEW CONSTRUCTION
AND AS INDICATED. USE METHODS REQUIRED TO COMPLETE THE WORK WITHIN LIMITATIONS OF GOVERNING REGULATIONS.
2. PROCEED WITH SELECTIVE DEMOLITION SYSTEMATICALLY, FROM HIGHER TO LOWER LEVEL.3. DISPOSE OF DEMOLISHED ITEMS AND MATERIALS PROMPTLY. EXCEPT FOR ITEMS OR MATERIALS INDICATED
TO BE REUSED, SALVAGED, REINSTALLED, OR OTHERWISE INDICATED TO REMAIN, REMOVE DEMOLISHED MATERIALS FROM SITE AND LEGALLY DISPOSE OF THEM IN AN EPA-APPROVED LANDFILL. DO NOT ALLOW DEMOLISHED MATERIALS TO ACCUMULATE ON-SITE.
4. DO NOT USE CUTTING TORCHES UNTIL WORK AREA IS CLEARED OF FLAMMABLE MATERIALS. MAINTAIN PORTABLE FIRE SUPPRESSION DEVICES DURING FLAME-CUTTING OPERATIONS.
5. MAINTAIN ADEQUATE VENTILATION WHEN USING CUTTING TORCHES.6. REMOVE DECAYED, VERMIN-INFESTED, OR OTHERWISE DANGEROUS OR UNSUITABLE MATERIALS AND
PROMPTLY DISPOSE OF OFF-SITE.7. LOCATE SELECTIVE DEMOLITION EQUIPMENT AND REMOVE DEBRIS AND MATERIALS SO AS NOT TO IMPOSE
EXCESSIVE LOADS ON SUPPORTING WALLS, FLOORS OR FRAMING.8. ALL SURFACES TO BE DEMOLISHED AND PREPPED FOR NEW. TO BE PREPPED ACCORDING TO NEW FINISHES
MANUFACTURERS WRITTEN INSTRUCTIONS.
UTILITY SERVICES AND MECHANICAL/ELECTRICAL SYSTEMS1. EXISTING SERVICES/SYSTEMS: MAINTAIN EXISTING SERVICES AND PROTECT THEM AGAINST DAMAGE DURING
SELECTIVE DEMOLITION OPERATIONS.2. SERVICE/SYSTEM REQUIREMENTS: LOCATE, IDENTIFY, DISCONNECT AND SEAL OR CAP OFF INDICATED UTILITY
SERVICES AND MECHANICAL/ELECTRICAL SYSTEMS SERVICING AREAS TO BE SELECTIVELY DEMOLISHED.
MASONRY1. DEMOLISH IN SMALL SECTIONS. CUT MASONRY AT JUNCTURES WITH CONSTRUCTION TO REMAIN, USING
POWER-DRIVEN SAW, THEN REMOVE MASONRY BETWEEN SAW CUTS.
CLEANING1. CLEAN ADJACENT STRUCTURES AND IMPROVEMENTS OF DUST, DIRT AND DEBRIS CAUSED BY SELECTIVE
DEMOLITION OPERATIONS. RETURN ADJACENT AREAS TO CONDITION EXISTING BEFORE SELECTIVE DEMOLITION OPERATIONS BEGAN.
TEMPORARY SHORING1. PROVIDE AND MAINTAIN SHORING, BRACING AND STRUCTURAL SUPPORTS AS REQUIRED TO PRESERVE
STABILITY AND PREVENT MOVEMENT, SETTLEMENT, OR COLLAPSE OF CONSTRUCTION AND FINISHES TO REMAIN, AND TO PREVENT UNEXPECTED OR UNCONTROLLED MOVEMENT OR COLLAPSE OF CONSTRUCTION BEING DEMOLISHED. STRENGTHEN OR ADD NEW SUPPORTS WHEN REQUIRED DURING PROGRESS OF SELECTIVE DEMOLITION.
PROJECT NUMBER
DATETHIS
DRA
WIN
G A
ND T
HE D
ESIG
N SH
OW
N TH
EREO
N AR
E PR
OPE
RTY
OF
STUD
IO 2
LR, I
NC.
THE
REPR
ODU
CTIO
N, C
OPY
ING
, OR
OTH
ER U
SE O
F TH
IS D
RAW
ING
WIT
HOUT
WRI
TTEN
CO
NSEN
T O
F ST
UDIO
2LR
, INC
. IS
PRO
HIBI
TED
AND
INFR
ING
EMEN
TS W
ILL
BE S
UBJE
CT T
O L
EGAL
ACT
ION.
STU
DIO
2LR
, IN
C.
24
28
MA
IN S
TR
EE
TC
OLU
MB
IA, S
C2
92
01
P 8
03
.23
3.6
60
2S
TU
DIO
2LR
.CO
M
CLI
EN
T N
AM
E
PR
OJE
CT
NA
ME
LOC
ATI
ON
SHEET NAME
SHEET NUMBER
C DBA
32
1
2/1/
2021
5:0
1:43
PM
20084
01/29/2021
AD101
AH
SS
BLD
G F
IRS
T FL
OO
RR
ES
TRO
OM
RE
NO
VA
TIO
NS
PR
OJE
CT
# H
29-I
364
5000
3418
DEMOLITION PLANS
UN
IVE
RS
ITY
OF
SO
UTH
CA
RO
LIN
A A
IKE
N
ISS
UE
D F
OR
BID
DIN
G, J
AN
UA
RY
29,
202
1
AIK
EN
, SO
UTH
CA
RO
LIN
A
1/8" = 1'-0"1 FIRST FLOOR DEMOLITION
N
PLAN NORTH
TRUE NORTH
N
REVISIONS
NO. DATE DESCRIPTION
MEN105
WOMEN104
COT ROOM104A
DP1DP2DP3DP4DP5DP6DP7
DP1DP2DP3DP4DP5DP6DP7
NO WORK THIS AREA
NO WORK THIS AREA
NO WORK THIS AREA
D E
DP8 DP8
DP9 DP9DP1DP2DP3
JANITOR114
WOMEN115
DP1DP2DP3DP4DP5DP6DP7
DP1DP2DP3DP4DP5DP6DP7
DP1DP2DP3DP4DP5DP6DP7
DP1DP2DP3DP4DP5DP6DP7
DP1DP2DP3
DP9
D E
DP8 DP8
DP8DP8
DP8
DP9
DP9 DP9
MEN118
GENERAL DEMOLITION NOTES1. EXISTING CONDITIONS AND DEMOLITION NOTES BASED ON EXISTING DRAWINGS BUT NOT ON AS BUILTS.
GENERAL CONTRACTOR TO FIELD VERIFY CONDITIONS PRIOR TO START OF CONSTRUCTION. IF GENERAL CONTRACTOR DISCOVERS EXISTING CONDITIONS DIFFER FROM THOSE SHOWN, NOTIFY OWNER OR ARCHITECT IMMEDIATELY.
2. GENERAL CONTRACTOR TO PROTECT ALL ADJACENT SURFACES TO REMAIN FROM DAMAGE DURING DEMOLITION. GENERAL CONTRACTOR TO REPAIR/REPLACE ANY ADJACENT SURFACES DAMAGED DURING CONSTRUCTION TO MATCH ORIGINAL CONDITIONS.
SELECTIVE DEMOLITION1. DEMOLISH AND REMOVE EXISTING CONSTRUCTION ONLY TO THE EXTENT REQUIRED BY NEW CONSTRUCTION
AND AS INDICATED. USE METHODS REQUIRED TO COMPLETE THE WORK WITHIN LIMITATIONS OF GOVERNING REGULATIONS.
2. PROCEED WITH SELECTIVE DEMOLITION SYSTEMATICALLY, FROM HIGHER TO LOWER LEVEL.3. DISPOSE OF DEMOLISHED ITEMS AND MATERIALS PROMPTLY. EXCEPT FOR ITEMS OR MATERIALS INDICATED
TO BE REUSED, SALVAGED, REINSTALLED, OR OTHERWISE INDICATED TO REMAIN, REMOVE DEMOLISHED MATERIALS FROM SITE AND LEGALLY DISPOSE OF THEM IN AN EPA-APPROVED LANDFILL. DO NOT ALLOW DEMOLISHED MATERIALS TO ACCUMULATE ON-SITE.
4. DO NOT USE CUTTING TORCHES UNTIL WORK AREA IS CLEARED OF FLAMMABLE MATERIALS. MAINTAIN PORTABLE FIRE SUPPRESSION DEVICES DURING FLAME-CUTTING OPERATIONS.
5. MAINTAIN ADEQUATE VENTILATION WHEN USING CUTTING TORCHES.6. REMOVE DECAYED, VERMIN-INFESTED, OR OTHERWISE DANGEROUS OR UNSUITABLE MATERIALS AND
PROMPTLY DISPOSE OF OFF-SITE.7. LOCATE SELECTIVE DEMOLITION EQUIPMENT AND REMOVE DEBRIS AND MATERIALS SO AS NOT TO IMPOSE
EXCESSIVE LOADS ON SUPPORTING WALLS, FLOORS OR FRAMING.8. ALL SURFACES TO BE DEMOLISHED AND PREPPED FOR NEW. TO BE PREPPED ACCORDING TO NEW FINISHES
MANUFACTURERS WRITTEN INSTRUCTIONS.
UTILITY SERVICES AND MECHANICAL/ELECTRICAL SYSTEMS1. EXISTING SERVICES/SYSTEMS: MAINTAIN EXISTING SERVICES AND PROTECT THEM AGAINST DAMAGE DURING
SELECTIVE DEMOLITION OPERATIONS.2. SERVICE/SYSTEM REQUIREMENTS: LOCATE, IDENTIFY, DISCONNECT AND SEAL OR CAP OFF INDICATED UTILITY
SERVICES AND MECHANICAL/ELECTRICAL SYSTEMS SERVICING AREAS TO BE SELECTIVELY DEMOLISHED.
MASONRY1. DEMOLISH IN SMALL SECTIONS. CUT MASONRY AT JUNCTURES WITH CONSTRUCTION TO REMAIN, USING
POWER-DRIVEN SAW, THEN REMOVE MASONRY BETWEEN SAW CUTS.
CLEANING1. CLEAN ADJACENT STRUCTURES AND IMPROVEMENTS OF DUST, DIRT AND DEBRIS CAUSED BY SELECTIVE
DEMOLITION OPERATIONS. RETURN ADJACENT AREAS TO CONDITION EXISTING BEFORE SELECTIVE DEMOLITION OPERATIONS BEGAN.
TEMPORARY SHORING1. PROVIDE AND MAINTAIN SHORING, BRACING AND STRUCTURAL SUPPORTS AS REQUIRED TO PRESERVE
STABILITY AND PREVENT MOVEMENT, SETTLEMENT, OR COLLAPSE OF CONSTRUCTION AND FINISHES TO REMAIN, AND TO PREVENT UNEXPECTED OR UNCONTROLLED MOVEMENT OR COLLAPSE OF CONSTRUCTION BEING DEMOLISHED. STRENGTHEN OR ADD NEW SUPPORTS WHEN REQUIRED DURING PROGRESS OF SELECTIVE DEMOLITION.
DEMOLITION PLAN NOTESDP1. REMOVE EXISTING CERAMIC FLOOR TILE COMPLETE. PREPARE SUBFLOOR FOR SPECIFIED FLOOR FINISH.DP2. REMOVE EXISTING CEILING SYSTEM COMPLETE INCLUDING ACOUSTICAL CEILING TILE, GRID, GRILLS, AND
LIGHTSDP3. REMOVE EXISTING CERAMIC BASE COMPLETE. PREPARE WALL FOR SPECIFIED FINISHES.DP4. REMOVE EXISTING TOILET ACCESSORIES. DELIVER TO OWNER.DP5. REMOVE EXISTING TOILET PARTITIONS COMPLETE. PATCH AND REPAIR WALLS FOR TOILET PARTITIONS.DP6. REMOVE EXISTING SINKS AND VANITIES COMPLETE. PATCH AND REPAIR WALLS FOR SINKS AND VANITIES.DP7. REMOVE EXISTING TOILETS AND URINALS COMPLETE.DP8. REMOVE EXISTING DOOR AND FRAME COMPLETE.DP9. REMOVE EXISTING WALL AS REQUIRED FOR INSTALLATION OF NEW DOOR AND FRAME TO MATCH EXISTING.
DP2 DP2
NO WORK THIS AREA
NO WORK THIS AREA
NO WORK THIS AREA
D E
DP2DP2
DP2DP2
DP2
D E
PROJECT NUMBER
DATETHIS
DRA
WIN
G A
ND T
HE D
ESIG
N SH
OW
N TH
EREO
N AR
E PR
OPE
RTY
OF
STUD
IO 2
LR, I
NC.
THE
REPR
ODU
CTIO
N, C
OPY
ING
, OR
OTH
ER U
SE O
F TH
IS D
RAW
ING
WIT
HOUT
WRI
TTEN
CO
NSEN
T O
F ST
UDIO
2LR
, INC
. IS
PRO
HIBI
TED
AND
INFR
ING
EMEN
TS W
ILL
BE S
UBJE
CT T
O L
EGAL
ACT
ION.
STU
DIO
2LR
, IN
C.
24
28
MA
IN S
TR
EE
TC
OLU
MB
IA, S
C2
92
01
P 8
03
.23
3.6
60
2S
TU
DIO
2LR
.CO
M
CLI
EN
T N
AM
E
PR
OJE
CT
NA
ME
LOC
ATI
ON
SHEET NAME
SHEET NUMBER
C DBA
32
1
2/1/
2021
5:0
1:48
PM
20084
01/29/2021
AD102
AH
SS
BLD
G F
IRS
T FL
OO
RR
ES
TRO
OM
RE
NO
VA
TIO
NS
PR
OJE
CT
# H
29-I
364
5000
3418
ENLARGED DEMOLITIONPLANS
UN
IVE
RS
ITY
OF
SO
UTH
CA
RO
LIN
A A
IKE
N
ISS
UE
D F
OR
BID
DIN
G, J
AN
UA
RY
29,
202
1
AIK
EN
, SO
UTH
CA
RO
LIN
A
1/4" = 1'-0"1 FIRST FLOOR - TOILETS 104 and 105 DEMOLITION
1/4" = 1'-0"3 FIRST FLOOR - TOILETS 115 and 118 DEMOLITION
1/4" = 1'-0"2 FIRST FLOOR - TOILETS 104 and 105 DEMOLITION
1/4" = 1'-0"4 FIRST FLOOR - TOILETS 115 and 118 DEMOLITION
N
PLAN NORTH
TRUE NORTH
N
N
PLAN NORTH
TRUE NORTH
N
N
PLAN NORTH
TRUE NORTH
N
N
PLAN NORTH
TRUE NORTH
N
REVISIONS
NO. DATE DESCRIPTION
UP
A4011
A4021
WOMEN115
JANITOR114
GENDERNEUTRAL
115A
MEN105
WOMEN104
MEN118
COT ROOM104A
NO WORK THIS AREA
NO WORK THIS AREA
NO WORK THIS AREA
NO WORK THIS AREA
NO WORK THIS AREA
NO WORK THIS AREA
CORRIDORH103
CORRIDORH102
01 PARTITIONSCALE: 1 1/2" = 1'-0"
CEILING HEIGHT AS SCHEDULED
STUD RUNNER ATTACHEDTO STRUCTURE
STRUCTURE
3 1/2" SOUND BATT WHERE IT OCCURS
3-5/8" METALSTUDS @ 16" O.C.
STUD RUNNER ATTACHED TO STRUCTURE
STRUCTURE
PLAN
SILL
HEA
D
4 7/8"
CONT. ACOUSTICAL SEALANT BOTH SIDES - SEALED TO
STRUCTURE
NOTE: WHERE RATING IS REQUIRED, GC SHALL MEET STANDARDS OF UL U465
AT FIRE RATED WALLS EXTENDGYPSUM BOARD TIGHT
TO STRUCTURE AND SEAL -PACK ALL VOIDS W/ FIRESAFING
MATERIAL
FINISH FLOOR MATERIAL WHERE IT OCCURS,
SEE FINISH SCHEDULE
BASE WHERE IT OCCURS, SEE FINISH SCHEDULE
5/8" GYP. BD. (TYPE "X" AT FIRE RATED PARTITIONS)
CEILING AS SHOWN ONREFLECTED CEILING PLANS
WHERE IT OCCURS
PLAN LEGEND
EXISTING WALL TO BE REMOVED
NEW WALL, SEE PARTITION TYPES
EXISTING WALL TO REMAIN
EXISTING DOOR TO BE REMOVED
NEW DOOR, SEE DOOR SCHEDULE
EXISTING DOOR TO REMAIN
A WINDOW TAG, SEE PLAN AND WINDOW SCHEDULE
1 DEMOLITION TAG, SEE DEMOLITION PLAN AND NOTES
888.8 DOOR TAG, SEE PLAN AND DOOR SCHEDULE
1i WALL TAG, SEE PLAN AND PARTITION TYPES
Room name101
ROOM TAG, SEE PLAN AND FINISH SCHEDULE
PROJECT NUMBER
DATETHIS
DRA
WIN
G A
ND T
HE D
ESIG
N SH
OW
N TH
EREO
N AR
E PR
OPE
RTY
OF
STUD
IO 2
LR, I
NC.
THE
REPR
ODU
CTIO
N, C
OPY
ING
, OR
OTH
ER U
SE O
F TH
IS D
RAW
ING
WIT
HOUT
WRI
TTEN
CO
NSEN
T O
F ST
UDIO
2LR
, INC
. IS
PRO
HIBI
TED
AND
INFR
ING
EMEN
TS W
ILL
BE S
UBJE
CT T
O L
EGAL
ACT
ION.
STU
DIO
2LR
, IN
C.
24
28
MA
IN S
TR
EE
TC
OLU
MB
IA, S
C2
92
01
P 8
03
.23
3.6
60
2S
TU
DIO
2LR
.CO
M
CLI
EN
T N
AM
E
PR
OJE
CT
NA
ME
LOC
ATI
ON
SHEET NAME
SHEET NUMBER
C DBA
32
1
2/1/
2021
5:0
1:16
PM
20084
01/29/2021
A101
AH
SS
BLD
G F
IRS
T FL
OO
RR
ES
TRO
OM
RE
NO
VA
TIO
NS
PR
OJE
CT
# H
29-I
364
5000
3418
FLOOR PLAN
UN
IVE
RS
ITY
OF
SO
UTH
CA
RO
LIN
A A
IKE
N
ISS
UE
D F
OR
BID
DIN
G, J
AN
UA
RY
29,
202
1
AIK
EN
, SO
UTH
CA
RO
LIN
A
1/8" = 1'-0"1 FIRST FLOOR
N
PLAN NORTH
TRUE NORTH
N
REVISIONS
NO. DATE DESCRIPTION
A4022
A4012
B C D E F G H I J K
NO WORK THIS AREA
NO WORK THIS AREA
NO WORK THIS AREA
NO WORK THIS AREA
NO WORK THIS AREA
NO WORK THIS AREA
X'-X" AFF CEILING HEIGHT ABOVE FINISHED FLOOR
REFLECTED CEILING PLAN LEGEND
2'x2' LIGHTING FIXTURE
2'x4' LIGHTING FIXTURE
GYPSUM BOARD CEILING. HEIGHT VARIES.
2'x2' MECHANICAL DIFFUSER
2'x2' MECHANICAL RETURN
2'x2' ACOUSTICAL CEILING TILE. HEIGHT VARIES.
EF EXHAUST FAN 1'x4' LIGHTING FIXTURE
RECESSED CAN LIGHT
GENERAL REFLECTED CEILING PLAN NOTES1. SEE ELECTRICAL ENGINEERS DRAWINGS FOR LIGHTING DESIGN, POWER AND DATA LOCATIONS.2. MECHANICAL DIFFUSERS SHOWN FOR REFERENCE ONLY. SEE MECHANICAL DRAWINGS FOR
ADDITIONAL INFORMATION.3. ALL CEILING TILE TO BE CENTERED IN SPACE EXACTLY AS SHOWN UNLESS OTHERWISE NOTED.4. ALL PROJECT CEILINGS AND CEILING ELEMENTS TO BE INSTALLED PER THE REQUIREMENTS OF
SEISMIC DESIGN CATEGORY D PER IBC 2015 UNLESS NOTED OTHERWISE IN THE PROJECT DOCUMENTS. GC COORDINATE WITH ARCHITECT/ INTERIOR DESIGNER AS NEEDED.
7/8"
8" MAX.
EDGE TRACK
SUSPENDED CEILING TRACK
WIRE HANGER
HORIZONTAL BRACING
ARMSTRONG SEISMIC RX SYSTEM OR
EQUAL
WALL
METAL STRUT FASTENED TO MAIN RUNNER AND STRUCTURE ABOVE AS REQUIRED TO MEET SEISMIC D IBC CODE REQUIREMENTS.
12 GA. HANGER WIRE AS REQUIRED TO MEET SEISMIC
D IBC CODE REQUIREMENTS. PROVIDE 4
AT 90 DEGREES (NORTH, SOUTH, EAST, AND WEST)
OF EACH OTHER AND 45 DEGREES TO THE PLANE OF
THE CEILING
MAIN RUNNER
CROSS RUNNER
PROJECT NUMBER
DATETHIS
DRA
WIN
G A
ND T
HE D
ESIG
N SH
OW
N TH
EREO
N AR
E PR
OPE
RTY
OF
STUD
IO 2
LR, I
NC.
THE
REPR
ODU
CTIO
N, C
OPY
ING
, OR
OTH
ER U
SE O
F TH
IS D
RAW
ING
WIT
HOUT
WRI
TTEN
CO
NSEN
T O
F ST
UDIO
2LR
, INC
. IS
PRO
HIBI
TED
AND
INFR
ING
EMEN
TS W
ILL
BE S
UBJE
CT T
O L
EGAL
ACT
ION.
STU
DIO
2LR
, IN
C.
24
28
MA
IN S
TR
EE
TC
OLU
MB
IA, S
C2
92
01
P 8
03
.23
3.6
60
2S
TU
DIO
2LR
.CO
M
CLI
EN
T N
AM
E
PR
OJE
CT
NA
ME
LOC
ATI
ON
SHEET NAME
SHEET NUMBER
C DBA
32
1
2/1/
2021
5:0
1:22
PM
20084
01/29/2021
A110
AH
SS
BLD
G F
IRS
T FL
OO
RR
ES
TRO
OM
RE
NO
VA
TIO
NS
PR
OJE
CT
# H
29-I
364
5000
3418
REFLECTED CEILINGPLAN
UN
IVE
RS
ITY
OF
SO
UTH
CA
RO
LIN
A A
IKE
N
ISS
UE
D F
OR
BID
DIN
G, J
AN
UA
RY
29,
202
1
AIK
EN
, SO
UTH
CA
RO
LIN
A1/8" = 1'-0"1 FIRST FLOOR
N
PLAN NORTH
TRUE NORTH
N
3" = 1'-0"2 SEISMIC D DETAILS
REVISIONS
NO. DATE DESCRIPTION
TOP
OF
RIM
17" M
AX.
BOTT
OM
OF
REF
LEC
TIVE
SU
RFA
CE
3'-4
" MAX
.
TO O
PER
ABLE
PAR
T O
F FI
XTU
RE
48" M
AX.
48" M
AX.
TA7 - PAPER TOWELDISPENSER/DISPOSAL
TA11TA7
TA6
TA11 - BABY CHANGINGSTATION
TA6 - MIRRORURINAL
MIN
.
9"
MIN
.
27" M
IN. MIN.
8"
MAX.
6"
34" M
AX.
24" -
30"
48" M
AX.
TA9 - COAT/ROBE HOOK
TA10 - SANITARY NAPKIN
DISPOSAL
LAVATORY
TA9
TA10
TO
OPE
RAB
LE
DEV
ICE
17" -
19"
TA1
DOUBLE TOILETPAPER DISPENSER
44" -
48"
TA5
TA5 - WALL MOUNTED
SOAP DISPENSER
39" -
41"
18" M
IN.
39" - 41"
TA1
TA2TA3
TA4
15" M
IN.
33" -
36"
TO
P O
F BA
R
TA3TA2
TA4
WATER CLOSETTA1 - TOILET PAPER DISPENSER
TA2 - 42" GRAB BARTA3 - 36" GRAB BAR
TA4 - 18" VERTICAL GRAB BAR
TOP
OF
SEAT
17" -
19"
MAX
.
7" - 9"
12" MIN.
18" MIN.
TA12
TA12 - FULL LENGTH MIRROR
2' - 0"
1' -
0"5'
- 0"
TA13 - HAND DRYER
TO O
PER
ABLE
PAR
T O
F FI
XTU
RE
48" M
AX.
TA13
TOILET ACCESSORY NOTES1. GC COORD. ALL ACCESSORIES WITH OWNER.2. INSTALL ALL TOILET ACCESSORIES PER MANUFACTURER'S WRITTEN INSTRUCTIONS AND PER ADA AND ANSI
A117.1 GUIDELINES AS REQUIRED.3. GC FURNISH AND INSTALL BLOCKING AS REQUIRED FOR ALL TOILET ACCESSORIES.4. INSTALL ADA SIGNAGE PER ADA AND ANSI A117.15. COORDINATE INSTALLATION OF HAND DRYERS AND LIGHT FIXTURES WITH ELECTRICAL DRAWINGS.
TOILET ACCESSORIES
TA1 TOILET TISSUE DISPENSERTA2 GRAB BAR 42"TA3 GRAB BAR 36"TA4 GRAB BAR 18" VERTICALTA5 SOAP DISPENSERTA6 MIRRORTA7 PAPER TOWEL DISPENSER/DISPOSALTA8 NOT USEDTA9 COAT HOOKTA10 SANITARY NAPKIN DISPOSALTA11 BABY CHANGING STATIONTA12 FULL LENGTH MIRRORTA13 ELECTRIC HAND DRYER
MEN105
WOMEN104
NO WORK
NO WORK
NO WORK
01 01
D E
A401 3
A401 4
TA1
TA1
TA1
TA1
TA1
TA1
TA2
TA2
TA2
TA2
TA5
TA6
TA6
TA5
TA6
TA6
TA5
TA6
TA7TA13 TA7TA13
TA12TA12
TA10
TA10
TA10
104A
40 SF
COT ROOM104A
5
6
5' - 0"
TA13
TA10
12' -
0"
30" C
LEAR
V.I.F
.
3' -
2"
V.I.F
.
2' -
9"
V.I.F
.
2' -
9"
V.I.F
.
2' -
9"
5' -
6"
V.I.F
.
2' -
9"
V.I.F
.
3' -
2"
5' - 0"
30" C
LEAR
30" C
LEAR
V.I.F
.
2' -
8"
V.I.F
.
2' -
8"
V.I.F
.
2' -
8"
V.I.F
.
3' -
0"
2' - 0"
5' - 0" CLR.CLR.
ø 5' - 0"
CLR.ø 5' - 0"
5' - 0" CLR.
7
A401
7
A401
4' - 6" CLR. 4' - 6" CLR.
FD FD
5' -
0" C
LR.
5' -
0" C
LR.
4' -
0" C
LR.
4' -
0" C
LR.
8" 8"
105 104
CORRIDORH103
SEE FLOOR PLAN NOTE 3
SEE FLOOR PLAN NOTE 3
D E
MEN105
WOMEN104
COT ROOM104A
NO WORK
NO WORK NO WORK
9' - 4" 9' - 4"
9' - 4"
FIRST FLOOR0"
PL1SS1
TP1
6"6"
5' -
0"3'
- 4"
9' -
4"
6"2'
- 4"
6"3'
- 4"
2' -
8"
9' -
4"
7
A401
TA6 TA6
NEW LIGHT AS SCHEDULED. COORDINATE WITH ELECTRICAL. CENTER OVER SINK AND MIRROR.
REMOVABLE ACCESS PANEL
FIRST FLOOR0"
PL1
SS1
6"2'
- 4"
6"3'
- 4"
2' -
8"
9' -
4"
TA6 TA6 TA6
NEW LIGHT AS SCHEDULED. COORDINATE WITH ELECTRICAL. CENTER OVER SINK AND MIRROR.
REMOVABLE ACCESS PANEL12' - 0"
7
A401
FIRST FLOOR0"
TP1
6"6"
5' -
0"3'
- 4"
9' -
4"
FIRST FLOOR0"
104A
TP1
3' -
4"5'
- 0"
6"6"
9' -
4"
PLASTIC LAMINATE ADA APRON FRONT WITH
REMOVABLE ACCESS PANEL AND CLIPS, PL1
PL1
SS1
UNDERMOUNT SINK AS SPECIFIED
FAUCET AS SPECIFIED
8"11"6"
9"1'
- 6"
5 1/
2"1
1/2"
A.F.
F.
2' -
10" M
AX.
2' - 1"
PROJECT NUMBER
DATETHIS
DRA
WIN
G A
ND T
HE D
ESIG
N SH
OW
N TH
EREO
N AR
E PR
OPE
RTY
OF
STUD
IO 2
LR, I
NC.
THE
REPR
ODU
CTIO
N, C
OPY
ING
, OR
OTH
ER U
SE O
F TH
IS D
RAW
ING
WIT
HOUT
WRI
TTEN
CO
NSEN
T O
F ST
UDIO
2LR
, INC
. IS
PRO
HIBI
TED
AND
INFR
ING
EMEN
TS W
ILL
BE S
UBJE
CT T
O L
EGAL
ACT
ION.
STU
DIO
2LR
, IN
C.
24
28
MA
IN S
TR
EE
TC
OLU
MB
IA, S
C2
92
01
P 8
03
.23
3.6
60
2S
TU
DIO
2LR
.CO
M
CLI
EN
T N
AM
E
PR
OJE
CT
NA
ME
LOC
ATI
ON
SHEET NAME
SHEET NUMBER
C DBA
32
1
2/1/
2021
5:0
1:29
PM
20084
01/29/2021
A401
AH
SS
BLD
G F
IRS
T FL
OO
RR
ES
TRO
OM
RE
NO
VA
TIO
NS
PR
OJE
CT
# H
29-I
364
5000
3418
ENLARGED PLANS RMS104 and 105
UN
IVE
RS
ITY
OF
SO
UTH
CA
RO
LIN
A A
IKE
N
ISS
UE
D F
OR
BID
DIN
G, J
AN
UA
RY
29,
202
1
AIK
EN
, SO
UTH
CA
RO
LIN
A
1/4" = 1'-0"1 FIRST FLOOR - TOILETS 104 and 1051/4" = 1'-0"2 FIRST FLOOR - TOILETS 104 and 105
1/4" = 1'-0"4 INTERIOR ELEVATION - 105 E
1/4" = 1'-0"3 INTERIOR ELEVATION - 104 E
1/4" = 1'-0"5 INTERIOR ELEVATION - 105 W
1/4" = 1'-0"6 INTERIOR ELEVATION - 104 W
N
PLAN NORTH
TRUE NORTH
N
N
PLAN NORTH
TRUE NORTH
N
1/2" = 1'-0"7 TYP. VANITY SECTION
FLOOR PLAN NOTES
1. CONTRACTOR VERIFY EXISTING FLOOR DRAIN LOCATIONS AND COORDINATE WITH TILE SPECIFICATIONS AND INSTALLATION PER MANUFACTURERS WRITTEN INSTRUCTIONS. TILE INSTALLATIONS TO MEET NTMA GUIDELINES.
2. COORDINATE PLUMBING FIXTURES WITH PLUMBING DRAWINGS.
3. PATCH AND REPAIR WALLS WHERE DOORS AND FRAMES WERE DEMOED. SEE FINISH PLANS FOR EXTENT OF NEW PAINT AND BASE IN CORRIDORS.
CEILING PLAN NOTES
1. COORDINATE MECHANICAL GRILLE LOCATIONS WITH MECHANICAL DRAWINGS.
2. COORDINATE LIGHT FIXTURES WITH ELECTRICAL DRAWINGS.
REVISIONS
NO. DATE DESCRIPTION
JANITOR114
WOMEN115
GENDERNEUTRAL
115A
TA12
TA13
TA7
TA5
TA6
TA3
TA1TA2
TA4
TA9
TA10
TA11
TA3
TA1TA2
TA4
TA13 TA7
TA5
TA5
TA6
TA6
TA6
TA6
TA6TA5
TA7
TA2
TA2TA2
TA2
TA1
TA1
TA1
TA1
TA10
TA1 TA10
TA1 TA10
TA10
TA12
114
115A
0101
01
01
01
D E
A4027 6A402 8
A40210
MEN118
9
V.I.F
.
2' -
8"
V.I.F
.
2' -
8"
V.I.F
.
2' -
8"
V.I.F
.
3' -
0"
2' - 0" 2' - 4"
30" C
LEAR
5' -
6"
V.I.F
.
2' -
10"
V.I.F
.
3' -
2"
5' - 0"
CLR.ø 5' - 0"
ø 5' - 0" CLR.
5' - 0" CLR.
V.I.F
.
2' -
9"
V.I.F
.
2' -
9"
V.I.F
.
2' -
10"
V.I.F
.
3' -
2"
10' -
4"
30" C
LEAR
5' - 0" CLR.
CLR.ø 5' - 0"
CLRø 5' - 0
"30" C
LEAR
5' - 0"5' - 0"
7
A401
7
A401
4' - 6" CLR. 4' - 6" CLR.
FD FD
5' -
0" C
LR.
5' -
0" C
LR.
4' -
0" C
LR.
4' -
0" C
LR.
30" C
LEAR
3' - 6"
TA13 TA7
115118
CORRIDORH102
8" 8"
SEE FLOOR PLAN NOTE 3
SEE FLOOR PLAN NOTE 3
D E
GENDERNEUTRAL
115A
WOMEN115
JANITOR114
MEN118
9' - 4"
9' - 4"
9' - 4"
TOILET ACCESSORIES
TA1 TOILET TISSUE DISPENSERTA2 GRAB BAR 42"TA3 GRAB BAR 36"TA4 GRAB BAR 18" VERTICALTA5 SOAP DISPENSERTA6 MIRRORTA7 PAPER TOWEL DISPENSER/DISPOSALTA8 NOT USEDTA9 COAT HOOKTA10 SANITARY NAPKIN DISPOSALTA11 BABY CHANGING STATIONTA12 FULL LENGTH MIRRORTA13 ELECTRIC HAND DRYER
TOILET ACCESSORY NOTES1. GC COORD. ALL ACCESSORIES WITH OWNER.2. INSTALL ALL TOILET ACCESSORIES PER MANUFACTURER'S WRITTEN INSTRUCTIONS AND PER ADA AND ANSI
A117.1 GUIDELINES AS REQUIRED.3. GC FURNISH AND INSTALL BLOCKING AS REQUIRED FOR ALL TOILET ACCESSORIES.4. INSTALL ADA SIGNAGE PER ADA AND ANSI A117.15. COORDINATE INSTALLATION OF HAND DRYERS AND LIGHT FIXTURES WITH ELECTRICAL DRAWINGS.
5 3/4"
3 5/8" METAL STUD
5/8" GYP. BD. (TYPE "X" AT FIRE RATED
PARTITIONS)
STUD RUNNER
CONT. SEALANT BOTH SIDES, TYP.
HOLLOW METAL DOOR FRAME
DOOR AS SCHEDULED
H1
5 3/4"
3 5/8" METAL STUD
5/8" GYP. BD. (TYPE "X" AT FIRE RATED
PARTITIONS)DOUBLE METAL
STUDS AT JAMBS
CONT. SEALANT BOTH SIDES, TYP.
HOLLOW METAL DOOR FRAME
DOOR AS SCHEDULED
J1
EQ.1 7/8"EQ.
EQ.1 7/8"EQ.
4 7/8"
5/8"
2"5/
8"2"
4 7/8"
3 1/2" SOUND BATTS WHERE IT OCCURS
3 1/2" SOUND BATTS WHERE IT OCCURS
A
DR
HEI
GH
T
DR WIDTH
HOLLOW METAL FRAME
2"
2"D
OO
R H
T.
1
FIRST FLOOR0"
TP1
PL1
SS19' -
4"
2' -
10"
6"3'
- 4"
2' -
8"
3' -
4"5'
- 0"
6"6"
9' -
4"
TA6 TA6
NEW LIGHT AS SCHEDULED. COORDINATE WITH ELECTRICAL. CENTER OVER SINK AND MIRROR.
REMOVABLE ACCESS PANEL
7
A401
FIRST FLOOR0"
SS1
PL1
6"2'
- 4"
6"3'
- 4"
2' -
8"
9' -
4"
TA6 TA6 TA6
NEW LIGHT AS SCHEDULED. COORDINATE WITH ELECTRICAL. CENTER OVER SINK AND MIRROR.
REMOVABLE ACCESS PANEL
7
A401
FIRST FLOOR0"
6"2'
- 4"
6"3'
- 4"
2' -
8"
9' -
4"
TA6TA11
NEW LIGHT AS SCHEDULED. COORDINATE WITH ELECTRICAL. CENTER OVER SINK AND MIRROR.
FIRST FLOOR0"
TP1
6"6"
5' -
0"3'
- 4"
9' -
4"
FIRST FLOOR0"
TP1
6"6"
5' -
0"3'
- 4"
9' -
4"
PROJECT NUMBER
DATETHIS
DRA
WIN
G A
ND T
HE D
ESIG
N SH
OW
N TH
EREO
N AR
E PR
OPE
RTY
OF
STUD
IO 2
LR, I
NC.
THE
REPR
ODU
CTIO
N, C
OPY
ING
, OR
OTH
ER U
SE O
F TH
IS D
RAW
ING
WIT
HOUT
WRI
TTEN
CO
NSEN
T O
F ST
UDIO
2LR
, INC
. IS
PRO
HIBI
TED
AND
INFR
ING
EMEN
TS W
ILL
BE S
UBJE
CT T
O L
EGAL
ACT
ION.
STU
DIO
2LR
, IN
C.
24
28
MA
IN S
TR
EE
TC
OLU
MB
IA, S
C2
92
01
P 8
03
.23
3.6
60
2S
TU
DIO
2LR
.CO
M
CLI
EN
T N
AM
E
PR
OJE
CT
NA
ME
LOC
ATI
ON
SHEET NAME
SHEET NUMBER
C DBA
32
1
2/1/
2021
5:0
1:33
PM
20084
01/29/2021
A402
AH
SS
BLD
G F
IRS
T FL
OO
RR
ES
TRO
OM
RE
NO
VA
TIO
NS
PR
OJE
CT
# H
29-I
364
5000
3418
ENLARGED PLANS RMS115 and 118, DOOR SCHED
UN
IVE
RS
ITY
OF
SO
UTH
CA
RO
LIN
A A
IKE
N
ISS
UE
D F
OR
BID
DIN
G, J
AN
UA
RY
29,
202
1
AIK
EN
, SO
UTH
CA
RO
LIN
A
1/4" = 1'-0"1 FIRST FLOOR - TOILETS 115 and 1181/4" = 1'-0"2 FIRST FLOOR - TOILETS 115 and 118
DOOR SCHEDULE
NUMBERSIZE DOOR FIRE
RATINGFRAME
HEAD JAMB SILL COMMENTSWIDTH HEIGHT TYPE MATERIAL FINISH TYPE MATERIAL FINISH
104 3' - 0" 7' - 0" A WOOD MATCHEXIST.
20 MIN. 1 HM P2 1 1 -- NEW DOOR AND FRAME TO MATCH EXISTING.
104A 3' - 0" 7' - 0" A WOOD MATCHEXIST.
-- 1 HM P2 1 1 -- NEW DOOR AND FRAME TO MATCH EXISTING.
105 3' - 0" 7' - 0" A WOOD MATCHEXIST.
20 MIN. 1 HM P2 1 1 -- NEW DOOR AND FRAME TO MATCH EXISTING.
114 3' - 0" 7' - 0" A WOOD MATCHEXIST.
20 MIN. 1 HM P2 1 1 -- NEW DOOR AND FRAME TO MATCH EXISTING.
115 3' - 0" 7' - 0" A WOOD MATCHEXIST.
20 MIN. 1 HM P2 1 1 -- NEW DOOR AND FRAME TO MATCH EXISTING.
115A 3' - 0" 7' - 0" A WOOD MATCHEXIST.
20 MIN. 1 HM P2 1 1 -- NEW DOOR AND FRAME TO MATCH EXISTING.
118 3' - 0" 7' - 0" A WOOD MATCHEXIST
20 MIN. 1 HM P2 1 1 -- NEW DOOR AND FRAME TO MATCH EXISTING.
1 1/2" = 1'-0"3 01 - HEAD AND JAMB DETAIL
1/4" = 1'-0"4 DOOR TYPES1/4" = 1'-0"5 FRAME TYPES
1/4" = 1'-0"6 INTERIOR ELEVATION - 118 E
1/4" = 1'-0"8 INTERIOR ELEVATION - 115 E
1/4" = 1'-0"10 INTERIOR ELEVATION - 115A
1/4" = 1'-0"7 INTERIOR ELEVATION - 118 W
1/4" = 1'-0"9 INTERIOR ELEVATION - 115 W
N
PLAN NORTH
TRUE NORTH
N
N
PLAN NORTH
TRUE NORTH
N
FLOOR PLAN NOTES
1. CONTRACTOR VERIFY EXISTING FLOOR DRAIN LOCATIONS AND COORDINATE WITH TILE SPECIFICATIONS AND INSTALLATION PER MANUFACTURERS WRITTEN INSTRUCTIONS. TILE INSTALLATIONS TO MEET NTMA GUIDELINES.
2. COORDINATE PLUMBING FIXTURES WITH PLUMBING DRAWINGS.
3. PATCH AND REPAIR WALLS WHERE DOORS AND FRAMES WERE DEMOED. SEE FINISH PLANS FOR EXTENT OF NEW PAINT AND BASE IN CORRIDORS.
CEILING PLAN NOTES
1. COORDINATE MECHANICAL GRILLE LOCATIONS WITH MECHANICAL DRAWINGS.
2. COORDINATE LIGHT FIXTURES WITH ELECTRICAL DRAWINGS.
REVISIONS
NO. DATE DESCRIPTION
D E
3
A700
3
A700
COT ROOM104A
WOMEN104
MEN105
T3(GRAIN
DIRECTION)
T3(GRAIN
DIRECTION)
T3(GRAIN
DIRECTION)
P3/B3 P3/B3
NO WORK THIS AREA
NO WORK THIS AREA
NO WORK THIS AREA
CORRIDORH103
D E
3
A7003
A700
3
A700
JANITOR114
MEN118
GENDERNEUTRAL
115A
WOMEN115
P3/B3
CORRIDORH102
TILE
SUBFLOOR
SCHLUTER RENO-U AEU100 TRANSITION STRIP. CONFIRM ADA COMPLIANCE.
EXIST. VINYL FLOORING
EQ EQCL
DOOR
NO WORK THIS AREA
PORCELAIN TILE, T3
EXIST. CONCRETE
FINISH PLAN LEGEND
GENERAL FINISH NOTES1. WALL FINISH DIRECTION IS BASED ON PLAN ORIENTATION (I.E. NORTH WALL REFERS TO PLAN NORTH)2. PROVIDE CODE COMPLIANT TRANSITION STRIPS WHERE NEEDED.3. PREP ALL SUB SURFACES TO RECEIVE NEW FINISH PER MANUFACTURER'S WRITTEN INSTRUCTIONS.4. ALL FINISHES TO BE SUBMITTED TO OWNER FOR APPROVAL PRIOR TO ORDERING/FABRICATING.5. WHERE FLOOR TRENCHING OCCURS, LEVEL AND PREP NEW CONCRETE SUBSTRATE TO RECEIVE NEW
FINISHES PER MANUFACTURER'S WRITTEN INSTRUCTIONS.6. ALL DIMENSIONS ARE FROM EXISTING CONDITIONS. VERIFY IN FIELD AND CONTACT ARCHITECT IF
DISCREPANCIES PRIOR TO INSTALLATION.7. TRANSITIONS AT DOORWAY TO OCCUR AT CENTERLINE OF CLOSED DOOR (SEE DETAIL). PROVIDE FLOOR
TRANSITION STRIPS BETWEEN NEW AND EXISTING FLOORING. CONTRACTOR CONFIRM ALL LOCATIONS.
PROJECT NUMBER
DATETHIS
DRA
WIN
G A
ND T
HE D
ESIG
N SH
OW
N TH
EREO
N AR
E PR
OPE
RTY
OF
STUD
IO 2
LR, I
NC.
THE
REPR
ODU
CTIO
N, C
OPY
ING
, OR
OTH
ER U
SE O
F TH
IS D
RAW
ING
WIT
HOUT
WRI
TTEN
CO
NSEN
T O
F ST
UDIO
2LR
, INC
. IS
PRO
HIBI
TED
AND
INFR
ING
EMEN
TS W
ILL
BE S
UBJE
CT T
O L
EGAL
ACT
ION.
STU
DIO
2LR
, IN
C.
24
28
MA
IN S
TR
EE
TC
OLU
MB
IA, S
C2
92
01
P 8
03
.23
3.6
60
2S
TU
DIO
2LR
.CO
M
CLI
EN
T N
AM
E
PR
OJE
CT
NA
ME
LOC
ATI
ON
SHEET NAME
SHEET NUMBER
C DBA
32
1
2/1/
2021
5:0
1:38
PM
20084
01/29/2021
A700
AH
SS
BLD
G F
IRS
T FL
OO
RR
ES
TRO
OM
RE
NO
VA
TIO
NS
PR
OJE
CT
# H
29-I
364
5000
3418
FINISH SPECS, FINISHSCHEDULE, FINISH PLANS
UN
IVE
RS
ITY
OF
SO
UTH
CA
RO
LIN
A A
IKE
N
ISS
UE
D F
OR
BID
DIN
G, J
AN
UA
RY
29,
202
1
AIK
EN
, SO
UTH
CA
RO
LIN
A
TS1 METAL TRANSITIONSTRIP SCHLUTER RENO-U AEU100 --
TRANSITION STRIPS (TS)
TP1SOLID PHENOLIC FLOOR
MOUNTED TOILETPARTITIONS
GENERAL PARTITIONS
TBD FROM MANUFACTURER'S STANDARDFINISHES. PROVIDE MFR. STANDARD COATHOOK IN EACH STALL, TYP. PROVIDE SHOP
DRAWINGS FOR REVIEW.--
TOILET PARTITIONS (TP)
B3 RUBBER BASE TARKETT COLOR: NAVY BLUE 4" COVE BASE INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS
B2 RUBBER BASE TARKETT COLOR: GREY 4" COVE BASE INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS
B1 TILE BASE ATLAS CONCORDE PATTERN: FRAY; COLOR: GRAY 6" X 12" COVE BASE
BASE (B)
SS1 SOLID SURFACE CORIAN CARBON CONCRETE --
SOLID SURFACE (SS)
PL1 PLASTIC LAMINATE WILSONART PATTERN: SATIN STAINLESS 4'W X 8'L APRONS AT ALL VANITIES
PLASTIC LAMINATE (PL)
P3 WALL PAINT SHERWIN WILLIAMS COLOR: SW 6244 NAVAL; FINISH: EGGSHELL --
P2 METAL DOOR FRAMEPAINT SHERWIN WILLIAMS COLOR: SW 7674 PEPPERCORN; FINISH:
SATIN --
P1 WALL PAINT SHERWIN WILLIAMS COLOR: SW 7029 AGREEABLE GRAY; FINISH:SEMIGLOSS --
PAINT (P)
GT1 GROUT LATICRETE COLOR: 78 STERLING SILVER --
GROUT (GT)
T3 PORCELAIN TILE ATLAS CONCORDE PATTERN: FRAY; COLOR: GRAY 12"L X 24" W; 3/8" THICK
INSTALL IN STACK BOND PER FINISH PLAN; RUN LENGTH PLAN NORTHTO PLAN SOUTH; CENTER PATTERN IN ROOM; ALIGN GROUT JOINTS
WITH WALL TILE GROUT JOINTS ON PLAN EAST AND PLAN WEST WALLS;USE GT1; SCHLUTER RENO-U AEU100 AT FLOOR TRANSITION TO LVT
T2 PORCELAIN TILE INTERCERAMIC PATTERN: IC BRITES; COLOR: WHITE 4 1/4" L X 12 1/4" W; 1/4" THICK INSTALL IN HORIZONTAL STACK BOND PER INTERIOR ELEVATIONS;ALIGN GROUT JOINTS WITH FLOOR TILE JOINTS; USE GT1
T1 PORCELAIN TILE INTERCERAMIC PATTERN: IC BRITES; COLOR: JET BLUE 4 1/4" L X 12 1/4" W; 1/4" THICK INSTALL IN HORIZONTAL STACK BOND PER INTERIOR ELEVATIONS;ALIGN GROUT JOINTS WITH FLOOR TILE JOINTS; USE GT1
TILE (T)
TAG ITEM MANUFACTURER DESCRIPTION SIZE NOTES
FINISH SPECIFICATION
ROOM FINISH SCHEDULE
NO. NAMEFLOOR BASE CEILING WALL FINISH
COMMENTSMATERIAL MATERIAL MATERIAL FINISH NORTH SOUTH EAST WEST
104 WOMEN T3 B1 ACT MFR P1 P1 T2 T1104A COT ROOM T3 B1 ACT MFR P1 P1 P1 P1105 MEN T3 B1 ACT MFR P1 P1 T2 T1114 JANITOR EXIST CONC B2 -- -- P1 P1 P1 P1115 WOMEN T3 B1 ACT MFR P1 P1 T2 T1115A GENDER NEUTRAL T3 B1 ACT MFR P1 P1 P1 T1118 MEN T3 B1 ACT MFR P1 P1 T2 T1H102 CORRIDOR EXIST B3 EXIST -- -- P3 -- -- SEE FINISH PLANS FOR EXTENT OF PAINT AND BASEH103 CORRIDOR EXIST B3 EXIST -- P3 -- -- -- SEE FINISH PLANS FOR EXTENT OF PAINT AND BASE
1/4" = 1'-0"1 FIRST FLOOR - TOILETS 104 and 105 FINISH PLAN
1/4" = 1'-0"2 FIRST FLOOR - TOILETS 115 and 118 FINISH PLAN
12" = 1'-0"3 TILE TO EXIST. VINYL
N
PLAN NORTH
TRUE NORTH
N
N
PLAN NORTH
TRUE NORTH
N
REVISIONS
NO. DATE DESCRIPTION
3 2
3
3
4
8
1
6
6
6
6
6
8
2
1
1
1
9
9
4
3
3
3
8 8
7 7
5
2
1
2
1
2
2
1
16
6
9
9
6
6
6
DEMOLITION NOTES
EXISTING WATER CLOSET TO BE REMOVED COMPLETE. EXISTING CHAIR CARRIER, SUPPLY, WASTE, AND VENT LINES TO BE REUSED FOR NEW FIXTURE.
EXISTING WATER CLOSET TO BE REMOVED COMPLETE INCLUDING CHAIR CARRIER. EXISTING WASTE, VENT, AND SUPPLY LINES TO BE REUSED FOR NEW FIXTURE. CAP EXISTING PIPING AS REQUIRED.
EXISTING URINAL TO BE REMOVED COMPLETE. EXISTING CHAIR CARRIER, SUPPLY, WASTE, AND VENT LINES TO BE REUSED FOR NEW FIXTURE.
EXISTING URINAL TO BE REMOVED COMPLETE INCLUDING CHAIR CARRIER. EXISTING WASTE, VENT, AND SUPPLY LINES TO BE REUSED FOR NEW FIXTURE. CAP EXISTING PIPING AS REQUIRED.
EXISTING URINAL TO BE REMOVED COMPLETE. CAP EXISTING PIPING AS REQUIRED.
EXISTING LAVATORY TO BE REMOVED COMPLETE. EXISTING WASTE, VENT, AND SUPPLY LINES TO BE REUSED FOR NEW FIXTURE.
EXISTING LAVATORY TO BE REMOVED COMPLETE. CAP EXISTING PIPING AS REQUIRED.
EXISTING FLOOR DRAIN TO BE REMOVED COMPLETE. EXISTING WASTE PIPING TO BE REUSED FOR NEW FLOOR DRAIN.
EXISTING HOSE BIB TO REMAIN.
1
2
3
4
5
6
7
8
9
REGISTERED
PR
OF
ES
SI O
N
A LE N G I N E E R
T O
DD
F.
SW
YG
E
RT
SO
UT
HC
AR
OL I N
A
No. 15574
C E R T I F I C
AT
EO
FA
UT
HO
RIZATION
SO
UT
HC
AR
OL I N
A
SWYG
ERT
AND
ASSO
CIAT
ES,
LTD.
NO
. C00
227
PROJECT NUMBER
DATE
TH
IS D
RA
WIN
G A
ND
TH
E D
ES
IGN
SH
OW
N T
HE
RE
ON
AR
E P
RO
PE
RT
Y O
F S
TU
DIO
2LR
, IN
C.
TH
E R
EP
RO
DU
CT
ION
, C
OP
YIN
G,
OR
OT
HE
R U
SE
OF
TH
IS D
RA
WIN
G W
ITH
OU
T W
RIT
TE
N C
ON
SE
NT
OF
ST
UD
IO 2
LR
, IN
C.
IS P
RO
HIB
ITE
D A
ND
IN
FR
ING
EM
EN
TS
WIL
L B
E S
UB
JEC
T T
O L
EG
AL
AC
TIO
N.
STU
DIO
2LR
, IN
C.
24
28
MA
IN S
TR
EE
T
CO
LU
MB
IA, S
C2
92
01
P 8
03
.23
3.6
60
2
STU
DIO
2LR
.CO
M
CLIE
NT
NA
ME
PR
OJE
CT
NA
ME
LO
CA
TIO
N
SHEET NAME
SHEET NUMBER
C DBA
32
1
C O N S U L T I N G E N G I N E E R S
Swygert & Associates
DBA Swygert & Assoc., Ltd.Post Office Box 11686
Columbia, S.C. 29211
Telephone: (803) 791-9300Facsimile: (803) 791-0830
20084
01/29/2021
PD101
AH
SS
BL
DG
FIR
ST
FL
OO
R
RE
ST
RO
OM
RE
NO
VA
TIO
NS
PR
OJE
CT
# H
29-I
364
500
03
41
8
DEMOLITION PLANS
UN
IVE
RS
ITY
OF
SO
UT
H C
AR
OLIN
A A
IKE
N
ISS
UE
D F
OR
BID
DIN
G, JA
NU
AR
Y 2
9, 2
02
1
AIK
EN
, S
OU
TH
CA
RO
LIN
A
1−29−21
1/4" = 1'-0"PD101
1 FIRST FLOOR - TOILETS 104 & 105 DEMOLITION1/4" = 1'-0"PD101
2 FIRST FLOOR - TOILETS 115 & 118 DEMOLITION
REVISIONS
NO. DATE DESCRIPTION
MEN
105
WOMEN
104
ELEV. EQUIP.
E2A
ELEC.
E2
ELEC.
E1
COT ROOM
104A
P-3A
3
P-3A
P-3A
P-3BADA
3
3
4
22
11
1
1
FD FD
P-2 P-2
P-1 P-1
P-1
P-1
6 6
5
5
5
5
5
P-4
P-4
P-4
P-4
P-4
JANITOR
114
WOMEN
115
GENDERNEUTRAL
115A
4
3
3
3
P-3A
P-3A
P-3A
P-3BADA
6 6
FD FD
5
5 5
5
5
P-4
P-4
P-5ADA
P-4
P-4
P-4
P-2
P-1
P-2 P-2
P-1
P-1
P-1
P-2
1
2
1
1
1
2
1½"
4" 4"
MEN
118
EXISTING VENT PIPINGTO BE REUSED
EXISTING VENT PIPINGTO BE REUSED
NOTES TO SHEET
RECONNECT TO EXISTING SANITARY WASTE LINE SERVING REMOVED WATER CLOSET. TRANSITION AS REQUIRED.
RECONNECT TO EXISTING SANITARY WASTE LINE SERVING REMOVED WATER CLOSET. ADJUST FOR NEW FIXTURE HEIGHT AND TRANSITION AS REQUIRED.
RECONNECT TO EXISTING SANITARY WASTE LINE SERVING REMOVED URINAL. TRANSITION AS REQUIRED.
RECONNECT TO EXISTING SANITARY WASTE LINE SERVING REMOVED URINAL. ADJUST FOR NEW FIXTURE HEIGHT AND TRANSITION AS REQUIRED.
RECONNECT TO EXISTING SANITARY WASTE LINE SERVING REMOVED LAVATORY. TRANSITION AS REQUIRED.
RECONNECT TO EXISTING SANITARY WASTE LINE SERVING REMOVED FLOOR DRAIN. TRANSITION AS REQUIRED.
1
2
3
4
5
6
REGISTERED
PR
OF
ES
SI O
N
A LE N G I N E E R
T O
DD
F.
SW
YG
E
RT
SO
UT
HC
AR
OL I N
A
No. 15574
C E R T I F I C
AT
EO
FA
UT
HO
RIZATION
SO
UT
HC
AR
OL I N
A
SWYG
ERT
AND
ASSO
CIAT
ES,
LTD.
NO
. C00
227
PROJECT NUMBER
DATE
TH
IS D
RA
WIN
G A
ND
TH
E D
ES
IGN
SH
OW
N T
HE
RE
ON
AR
E P
RO
PE
RT
Y O
F S
TU
DIO
2LR
, IN
C.
TH
E R
EP
RO
DU
CT
ION
, C
OP
YIN
G,
OR
OT
HE
R U
SE
OF
TH
IS D
RA
WIN
G W
ITH
OU
T W
RIT
TE
N C
ON
SE
NT
OF
ST
UD
IO 2
LR
, IN
C.
IS P
RO
HIB
ITE
D A
ND
IN
FR
ING
EM
EN
TS
WIL
L B
E S
UB
JEC
T T
O L
EG
AL
AC
TIO
N.
STU
DIO
2LR
, IN
C.
24
28
MA
IN S
TR
EE
T
CO
LU
MB
IA, S
C2
92
01
P 8
03
.23
3.6
60
2
STU
DIO
2LR
.CO
M
CLIE
NT
NA
ME
PR
OJE
CT
NA
ME
LO
CA
TIO
N
SHEET NAME
SHEET NUMBER
C DBA
32
1
C O N S U L T I N G E N G I N E E R S
Swygert & Associates
DBA Swygert & Assoc., Ltd.Post Office Box 11686
Columbia, S.C. 29211
Telephone: (803) 791-9300Facsimile: (803) 791-0830
20084
01/29/2021
P101
AH
SS
BL
DG
FIR
ST
FL
OO
R
RE
ST
RO
OM
RE
NO
VA
TIO
NS
PR
OJE
CT
# H
29-I
364
500
03
41
8
RENOVATION PLANS -
WASTE & VENT PIPING
UN
IVE
RS
ITY
OF
SO
UT
H C
AR
OLIN
A A
IKE
N
ISS
UE
D F
OR
BID
DIN
G, JA
NU
AR
Y 2
9, 2
02
1
AIK
EN
, S
OU
TH
CA
RO
LIN
A
1−29−21
1/4" = 1'-0"P101
1 FIRST FLOOR - TOILETS 104 & 105 RENOVATION1/4" = 1'-0"P101
2 FIRST FLOOR - TOILETS 115 & 118 RENOVATION
REVISIONS
NO. DATE DESCRIPTION
MEN
105
WOMEN
104
ELEV. EQUIP.
E2A
ELEC.
E2
ELEC.
E1
COT ROOM
104A
3
4
2
1
5
3
3
P-3BADA
P-3A
P-3A
P-3A
2
1
1
1
P-2
P-1
P-2
P-1
P-1
P-1
5
5
5
5
P-4
P-4
P-4
P-4
P-4
JANITOR
114
WOMEN
115
GENDERNEUTRAL
115A
4
3
3
3
P-3BADA
P-3A
P-3A
P-3A
1
1
2
1
1
2
P-2 P-2
P-1
P-1
P-1
P-2P-2
P-1
5
5
5
5
5
P-4
P-4
P-4
P-4
P-4
1"
1"
½"
P-5ADA
MEN
118
NOTES TO SHEET
RECONNECT TO EXISTING DOMESTIC WATER SUPPLY LINE SERVING REMOVED WATER CLOSET. TRANSITION AS REQUIRED.
RECONNECT TO EXISTING DOMESTIC WATER SUPPLY LINE SERVING REMOVED WATER CLOSET. ADJUST FOR NEW HEIGHT OF FIXTURE AND TRANSITION AS REQUIRED.
RECONNECT TO EXISTING DOMESTIC WATER SUPPLY LINE SERVING REMOVED URINAL. TRANSITION AS REQUIRED.
RECONNECT TO EXISTING DOMESTIC WATER SUPPLY LINE SERVING REMOVED URINAL. ADJUST FOR NEW HEIGHT OF FIXTURE AND TRANSITION AS REQUIRED.
RECONNECT TO EXISTING DOMESTIC HOT AND COLD WATER LINES SERVING REMOVED LAVATORY. TRANSITION AS REQUIRED.
1
2
3
4
5
REGISTERED
PR
OF
ES
SI O
N
A LE N G I N E E R
T O
DD
F.
SW
YG
E
RT
SO
UT
HC
AR
OL I N
A
No. 15574
C E R T I F I C
AT
EO
FA
UT
HO
RIZATION
SO
UT
HC
AR
OL I N
A
SWYG
ERT
AND
ASSO
CIAT
ES,
LTD.
NO
. C00
227
PROJECT NUMBER
DATE
TH
IS D
RA
WIN
G A
ND
TH
E D
ES
IGN
SH
OW
N T
HE
RE
ON
AR
E P
RO
PE
RT
Y O
F S
TU
DIO
2LR
, IN
C.
TH
E R
EP
RO
DU
CT
ION
, C
OP
YIN
G,
OR
OT
HE
R U
SE
OF
TH
IS D
RA
WIN
G W
ITH
OU
T W
RIT
TE
N C
ON
SE
NT
OF
ST
UD
IO 2
LR
, IN
C.
IS P
RO
HIB
ITE
D A
ND
IN
FR
ING
EM
EN
TS
WIL
L B
E S
UB
JEC
T T
O L
EG
AL
AC
TIO
N.
STU
DIO
2LR
, IN
C.
24
28
MA
IN S
TR
EE
T
CO
LU
MB
IA, S
C2
92
01
P 8
03
.23
3.6
60
2
STU
DIO
2LR
.CO
M
CLIE
NT
NA
ME
PR
OJE
CT
NA
ME
LO
CA
TIO
N
SHEET NAME
SHEET NUMBER
C DBA
32
1
C O N S U L T I N G E N G I N E E R S
Swygert & Associates
DBA Swygert & Assoc., Ltd.Post Office Box 11686
Columbia, S.C. 29211
Telephone: (803) 791-9300Facsimile: (803) 791-0830
20084
01/29/2021
P201
AH
SS
BL
DG
FIR
ST
FL
OO
R
RE
ST
RO
OM
RE
NO
VA
TIO
NS
PR
OJE
CT
# H
29-I
364
500
03
41
8
RENOVATION PLANS -
SUPPLY PIPING
UN
IVE
RS
ITY
OF
SO
UT
H C
AR
OLIN
A A
IKE
N
ISS
UE
D F
OR
BID
DIN
G, JA
NU
AR
Y 2
9, 2
02
1
AIK
EN
, S
OU
TH
CA
RO
LIN
A
1−29−21
1/4" = 1'-0"P201
1 FIRST FLOOR - TOILETS 104 & 105 RENOVATION1/4" = 1'-0"P201
2 FIRST FLOOR - TOILETS 115 & 118 RENOVATION
REVISIONS
NO. DATE DESCRIPTION
GENERAL NOTES
ALL WORK SHALL BE PERFORMED ACCORDING TO ALL LOCAL, STATE, NATIONAL CODES, AND THE 2018 INTERNATIONAL PLUMBING CODE. DO NOT SCALE DRAWINGS. SEE ARCHITECTURAL DRAWINGS FOR EXACT DIMENSIONS, FIXTURE LOCATIONS, ETC. EXCEPT WHERE PIPE SPACE IS PROVIDED OR UNLESS NOTED OTHERWISE, ALL SUPPLY, WASTE AND VENT RISERS SHALL BE RUN IN WALLS AND PARTITIONS. COORDINATE CLOSELY WITH ALL WORK DONE UNDER OTHER DIVISIONS OF THE SPECIFICATIONS TO AVOID INTERFERENCE AND CONFLICT. EXPOSED WASTE AND WATER PIPING UNDER LAVATORIES MARKED "ADA" SHALL BE INSULATED WITH HANDI LAV-GUARD KIT MODEL NUMBER 102 E-Z AS MANUFACTURED BY TRUEBRO, INC., OR APPROVED EQUAL. ALL PIPING INSULATION SHALL BE RUN CONTINUOUSLY.
1.
2.
3.
4.
5.
6.
LEGEND
DOMESTIC COLD WATER LINE
DOMESTIC HOT WATER LINE
SANITARY WASTE LINE
PIPE TURNS TO, AWAY
FIXTURE FOR USE ACCORDING TO THE AMERICANSWITH DISABILITIES ACT
ADA
,
SYMBOL DESCRIPTION
CONNECTION POINT OF NEW TO EXISTING
PLUMBING FIXTURE SCHEDULE
NOTE: SEE ARCHITECTURAL DRAWINGS FOR MOUNTING HEIGHTS OF ALL WALL MOUNTED FIXTURES.
P. NO.
P-1
MIN. SUPPLY
CW
1"KINGSTON
NAMEFIXTURE
KOHLER
MFGR.
K-4325
MFGRS. NO. SIZE
- - - - -
HW REMARKS
P-4 3/8"CAXTONLAVATORY KOHLER K-2210 17"x14" 3/8" UNDERCOUNTER MOUNTED WITH DELTA MODEL 590LF-HGMHDF SENSOR FAUCET, WATTS SERIES LFUSG-B ASSE 1070 APPROVED MIXING VALVE, McGUIRE 155 GRID DRAIN, McGUIRE H165 3/8" CAST BRASS SUPPLIES WITH STOPS, AND McGUIRE 8872 1-1/4" P-TRAP.
WATER CLOSET WITH SLOAN MODEL G2-8111 BATTERY POWERED SENSOR FLUSH VALVE, BENEKE 527 SEAT, AND BOLT CAPS. RECONNECT TO EXISTING CHAIR CARRIER.
FD - -- - -FLOOR DRAIN ZURN ZN-415-S - - - - - WITH 5"x5" NICKLE BRONZE STRAINER, P-TRAP, AND PROSET, OR APPROVED EQUAL, TRAP GUARD.
P-2 1"KINGSTONKOHLER K-4325 - - - - - WITH SLOAN MODEL G2-8111 BATTERY POWERED SENSOR FLUSH VALVE, BENEKE 527 SEAT, CHAIR CARRIER, AND BOLT CAPS.
P-3A 3/4"BARDONKOHLER K-4991-ET - - - - -URINAL WITH SLOAN MODEL G2-8186 BATTERY POWERED SENSOR FLUSH VALVE. RECONNECT TO EXISTING CHAIR CARRIER.
P-5 3/8"HUDSONLAVATORY KOHLER K-2868 20"x18" 3/8" WITH DELTA MODEL 590LF-HGMHDF SENSOR FAUCET, WATTS SERIES LFUSG-B ASSE 1070 APPROVED MIXING VALVE, McGUIRE 155 GRID DRAIN, McGUIRE H165 3/8" CAST BRASS SUPPLIES WITH STOPS, AND McGUIRE 8872 1-1/4" P-TRAP.
WATER CLOSET
P-3B 3/4"BARDONKOHLER K-4991-ET - - - - -URINAL WITH SLOAN MODEL G2-8186 BATTERY POWERED SENSOR FLUSH VALVE AND CHAIR CARRIER.
17" FINISHED WALL(TYP)
ADA PLAN VIEW (WHEELCHAIR ACCESS)
ELEVATION VIEW
GRAB BARS BYOTHERS (TYP.)
COORDINATE MOUNTING HEIGHT OFFLUSH VALVE WITH GRAB BARS
18"
18"
ADA PLAN VIEW (AMBULATORY ACCESS)
21" CLEAR MIN.
CENTERED BETWEENPARTITIONS (15" MIN)
CENTERED BETWEENPARTITIONS (15" MIN)
PLAN VIEW (STANDARD ACCESS)
21" CLEAR MIN.
P-1 (15" TO TOP OF FIXTURE)
P-2 (16½" TO TOP OF FIXTURE)
P-1P-2
BATTERY POWEREDSENSOR FLUSHVALVE
FINISHED WALL
SUPPLY PIPE SUPPORT
CLOSET CARRIERASSEMBLY
CAULK AROUND PERIMETEROF WALL MOUNTED FIXTURE
CLOSETCARRIERASSEMBLY
SUPPLY PIPESUPPORT
P-3B
3-3/4"
1" MIN., 4" MAX.
17" (ADA)
2-1/4"
SUPPLY PIPING SUPPORT(JOSAM M-126, OR EQUAL)
CAULK AROUNDPERIMETER OF WALL MOUNTEDFIXTURE
BATTERY POWEREDSENSOR FLUSHVALVE
FINISHEDFLOOR
FINISHEDWALL
PARTITIONS(BY OTHERS)
URINAL SHALL BE CENTEREDBETWEEN PARTITIONS
WELD CHANNEL TOSTUD (TYPICAL)
NOTCH STUD FLANGE TORECEIVE CHANNEL(TYPICAL)
SHOP OR FIELD PUNCHCHANNELS TO RECEIVEBOLT (TYPICAL)
TACK WELD BOLT HEAD TOCHANNEL WEB (TYPICAL)
USE LOCK WASHER ON FRONTSIDE OF BRACKET (TYPICAL)
STEEL WALL STUD(TYPICAL)
2 NESTED 1-1/2" MIN.STEEL CHANNELSFORMING BOX
3/8"Ø CARRIAGE BOLT xLENGTH REQUIREDNUMBER AS REQUIREDTO SECURE BRACKET,MIN. OF 2 (TYPICAL)
FULL WIDTH
OF FIXTURE
VARIES
P-5
NOTE:HOLES TO BE DRILLEDIN THE LAVATORY SHALLBE ACCOMPLISHED ATTHE FACTORY PRIOR TOTHE ENAMELING OF THEFIXTURE.
FINISHED WALL
CHANNEL BACK-UPASSEMBLY (SEEDETAIL)
CAST IRON LUG CASTINTEGRAL WITH FIXTUREOR STEEL ANGLE BRACKETBOLTED THROUGH APRONOF FIXTURE WITH CHROMEPLATED BOLTS. BOLT TOBACK PLATE.
34" MAX. AFF
28" MIN. AFF
15" MIN
15" MIN
DASHED LINE REPRESENTSANY SIDE WALL, PARTITION,VANITY, OR OTHER OBSTRUCTION
FINISHED WALL (TYP.)
SPECIFICATIONS
WASTE AND VENT PIPING:
ALL WASTE AND VENT PIPING SHALL BE STANDARD WEIGHT HUBLESS CAST IRON WITH HEAVY DUTY CLAMPS BY HUSKY OR MISSION.
SUPPLY PIPING:
ALL SUPPLY PIPING SHALL BE TYPE L COPPER WITH LEAD FREE JOINTS. INSULATE ALL SUPPLY PIPING WITH 1" THICK FIBERGLASS INSULATION WITH ALL SERVICE JACKET.
REGISTERED
PR
OF
ES
SI O
N
A LE N G I N E E R
T O
DD
F.
SW
YG
E
RT
SO
UT
HC
AR
OL I N
A
No. 15574
C E R T I F I C
AT
EO
FA
UT
HO
RIZATION
SO
UT
HC
AR
OL I N
A
SWYG
ERT
AND
ASSO
CIAT
ES,
LTD.
NO
. C00
227
PROJECT NUMBER
DATE
TH
IS D
RA
WIN
G A
ND
TH
E D
ES
IGN
SH
OW
N T
HE
RE
ON
AR
E P
RO
PE
RT
Y O
F S
TU
DIO
2LR
, IN
C.
TH
E R
EP
RO
DU
CT
ION
, C
OP
YIN
G,
OR
OT
HE
R U
SE
OF
TH
IS D
RA
WIN
G W
ITH
OU
T W
RIT
TE
N C
ON
SE
NT
OF
ST
UD
IO 2
LR
, IN
C.
IS P
RO
HIB
ITE
D A
ND
IN
FR
ING
EM
EN
TS
WIL
L B
E S
UB
JEC
T T
O L
EG
AL
AC
TIO
N.
STU
DIO
2LR
, IN
C.
24
28
MA
IN S
TR
EE
T
CO
LU
MB
IA, S
C2
92
01
P 8
03
.23
3.6
60
2
STU
DIO
2LR
.CO
M
CLIE
NT
NA
ME
PR
OJE
CT
NA
ME
LO
CA
TIO
N
SHEET NAME
SHEET NUMBER
C DBA
32
1
C O N S U L T I N G E N G I N E E R S
Swygert & Associates
DBA Swygert & Assoc., Ltd.Post Office Box 11686
Columbia, S.C. 29211
Telephone: (803) 791-9300Facsimile: (803) 791-0830
20084
01/29/2021
P301
AH
SS
BL
DG
FIR
ST
FL
OO
R
RE
ST
RO
OM
RE
NO
VA
TIO
NS
PR
OJE
CT
# H
29-I
364
500
03
41
8
DETAILS, NOTES,
SCHEDULE, & LEGEND
UN
IVE
RS
ITY
OF
SO
UT
H C
AR
OLIN
A A
IKE
N
ISS
UE
D F
OR
BID
DIN
G, JA
NU
AR
Y 2
9, 2
02
1
AIK
EN
, S
OU
TH
CA
RO
LIN
A
1−29−21
NO SCALE
WATER CLOSET MOUNTING AND SUPPLY DETAILS
NO SCALE
TYPICAL URINAL SUPPORT
NO SCALE
CHANNEL BACK - UP ASSEMBLY
NO SCALE
LAVATORY MOUNTING DETAILS
REVISIONS
NO. DATE DESCRIPTION
1
2 2
1
33
33
1
3
3
3
3
1
11
1
1
22
DEMOLITION NOTES
REMOVE EXHAUST GRILLE AND RUNOUT DUCT. PATCH TRUNK DUCT AND SEAL AS REQUIRED.
REMOVE SUPPLY GRILLE AND RUNOUT DUCT. PATCH TRUNK DUCT AND SEAL AS REQUIRED.
REMOVE TRANSFER DUCT AND GRILLES.
1
2
3
REGISTERED
PR
OF
ES
SI O
N
A LE N G I N E E R
W I L L I AM
C.
LIV
ING
STON
SO
UT
HC
AR
OL I N
A
No. 17994
C E R T I F I C
AT
EO
FA
UT
HO
RIZATION
SO
UT
HC
AR
OL I N
A
SWYG
ERT
AND
ASSO
CIAT
ES,
LTD.
NO
. C00
227
PROJECT NUMBER
DATE
TH
IS D
RA
WIN
G A
ND
TH
E D
ES
IGN
SH
OW
N T
HE
RE
ON
AR
E P
RO
PE
RT
Y O
F S
TU
DIO
2LR
, IN
C.
TH
E R
EP
RO
DU
CT
ION
, C
OP
YIN
G,
OR
OT
HE
R U
SE
OF
TH
IS D
RA
WIN
G W
ITH
OU
T W
RIT
TE
N C
ON
SE
NT
OF
ST
UD
IO 2
LR
, IN
C.
IS P
RO
HIB
ITE
D A
ND
IN
FR
ING
EM
EN
TS
WIL
L B
E S
UB
JE
CT
TO
LE
GA
L A
CT
ION
.
STU
DIO
2LR
, IN
C.
24
28
MA
IN S
TR
EE
T
CO
LU
MB
IA, S
C2
92
01
P 8
03
.23
3.6
60
2
STU
DIO
2LR
.CO
M
CLIE
NT
NA
ME
PR
OJE
CT
NA
ME
LO
CA
TIO
N
SHEET NAME
SHEET NUMBER
C DBA
32
1
C O N S U L T I N G E N G I N E E R S
Swygert & Associates
DBA Swygert & Assoc., Ltd.Post Office Box 11686
Columbia, S.C. 29211
Telephone: (803) 791-9300Facsimile: (803) 791-0830
20084
01/29/2021
MD101
AH
SS
BL
DG
FIR
ST
FL
OO
R
RE
ST
RO
OM
RE
NO
VA
TIO
NS
PR
OJE
CT
# H
29-I
364
500
03
41
8
DEMOLITION PLANS
UN
IVE
RS
ITY
OF
SO
UT
H C
AR
OLIN
A A
IKE
N
ISS
UE
D F
OR
BID
DIN
G, JA
NU
AR
Y 2
9, 2
02
1
AIK
EN
, S
OU
TH
CA
RO
LIN
A
1−29−21
1/4" = 1'-0"MD101
1 FIRST FLOOR - TOILETS 104 & 105 DEMOLITION1/4" = 1'-0"MD101
2 FIRST FLOOR - TOILETS 115 & 118 DEMOLITION
REVISIONS
NO. DATE DESCRIPTION
MEN
105
WOMEN
104
ELEV. EQUIP.
E2A
ELEC.
E2
ELEC.
E1
COT ROOM
104A
A 110
B 500
B 500
A 110
12ø
12ø
JANITOR
114
WOMEN
115
GENDER
NEUTRAL
115A
MEN
118
A 110
B 500 B 500
A 110
C 100
C 100
C 100
12ø
12ø
8ø
8ø
8ø
REGISTERED
PR
OF
ES
SI O
N
A LE N G I N E E R
W I L L I AM
C.
LIV
ING
STON
SO
UT
HC
AR
OL I N
A
No. 17994
C E R T I F I C
AT
EO
FA
UT
HO
RIZATION
SO
UT
HC
AR
OL I N
A
SWYG
ERT
AND
ASSO
CIAT
ES,
LTD.
NO
. C00
227
PROJECT NUMBER
DATE
TH
IS D
RA
WIN
G A
ND
TH
E D
ES
IGN
SH
OW
N T
HE
RE
ON
AR
E P
RO
PE
RT
Y O
F S
TU
DIO
2LR
, IN
C.
TH
E R
EP
RO
DU
CT
ION
, C
OP
YIN
G,
OR
OT
HE
R U
SE
OF
TH
IS D
RA
WIN
G W
ITH
OU
T W
RIT
TE
N C
ON
SE
NT
OF
ST
UD
IO 2
LR
, IN
C.
IS P
RO
HIB
ITE
D A
ND
IN
FR
ING
EM
EN
TS
WIL
L B
E S
UB
JE
CT
TO
LE
GA
L A
CT
ION
.
STU
DIO
2LR
, IN
C.
24
28
MA
IN S
TR
EE
T
CO
LU
MB
IA, S
C2
92
01
P 8
03
.23
3.6
60
2
STU
DIO
2LR
.CO
M
CLIE
NT
NA
ME
PR
OJE
CT
NA
ME
LO
CA
TIO
N
SHEET NAME
SHEET NUMBER
C DBA
32
1
C O N S U L T I N G E N G I N E E R S
Swygert & Associates
DBA Swygert & Assoc., Ltd.Post Office Box 11686
Columbia, S.C. 29211
Telephone: (803) 791-9300Facsimile: (803) 791-0830
20084
01/29/2021
M101
AH
SS
BL
DG
FIR
ST
FL
OO
R
RE
ST
RO
OM
RE
NO
VA
TIO
NS
PR
OJE
CT
# H
29-I
364
500
03
41
8
RENOVATION PLANS
UN
IVE
RS
ITY
OF
SO
UT
H C
AR
OLIN
A A
IKE
N
ISS
UE
D F
OR
BID
DIN
G, JA
NU
AR
Y 2
9, 2
02
1
AIK
EN
, S
OU
TH
CA
RO
LIN
A
1−29−21
1/4" = 1'-0"M101
1 FIRST FLOOR - TOILETS 104 & 105 RENOVATION1/4" = 1'-0"M101
2 FIRST FLOOR - TOILETS 115 & 118 RENOVATION
REVISIONS
NO. DATE DESCRIPTION
SPECIFICATIONSALL WORK SHALL BE IN ACCORDANCE WITH THE 2018 INTERNATIONAL MECHANICAL CODE, 2009 INTERNATIONAL ENERGY CONSERVATION CODE, AND 2006 SMACNA HVAC DUCT CONSTRUCTION STANDARD. ALL LOCAL CODES OR REQUIREMENTS STILL APPLY.
ALL RECTANGULAR DUCT SHALL BE TYPE G-60 GALVANIZED SHEET METAL, SEALED WITH LOW PRESSURE DUCT MASTIC. ROUND DUCTS SHALL BE GALVANIZED SHEET METAL SEALED WITH LOW PRESSURE DUCT MASTIC. LOCKING QUADRANT BALANCING DAMPERS SHALL BE INSTALLED IN EACH BRANCH TAKEOFF AT THE MAIN TRUNK DUCT. FLEXIBLE DUCT SHALL NOT EXCEED 5' IN LENGTH AND SHALL BE EQUAL TO FLEXMASTER TYPE 1M.
SUPPLY DUCTS SHALL BE INSULATED WITH 2" THICK, 3/4# DENSITY DUCT WRAP. DUCT WRAP SHALL BE SEALED WITH FIBERGLASS REINFORCING MESH, STAPLES AND MASTIC AT THE JOINTS.
SUBMIT ALL EQUIPMENT AND PRODUCTS PROPOSED TO BE USED FOR THIS PROJECT PRIOR TO ORDERING. SUBMIT SIX COPIES OF DATA SHEETS TO THE ENGINEER, BOUND IN A SINGLE VOLUME FOR APPROVAL.
SUBMIT A CERTIFIED ABB OR NEBB TEST AND BALANCE REPORT AT PROJECT COMPLETION PRIOR TO FINAL ACCEPTANCE. BALANCE FAN AIR VOLUMES TO WITHIN 5% OF DESIGN AND DIFFUSER AIR VOLUMES TO WITHIN 10% OF DESIGN.
ALL EQUIPMENT, PRODUCTS AND WORK SHALL BE GUARANTEED TO BE FREE OF DEFECTS IN MANUFACTURE AND WORKMANSHIP FOR A PERIOD OF ONE YEAR FROM THE DATE OF SUBSTANTIAL COMPLETION. ALL REPAIRS WILL BE MADE AT NO COST TO THE OWNER.
1.
2.
3.
4.
5.
6.
100A
LEGEND
TYPE "A" DIFFUSER, 100 CFM
SYMBOL DESCRIPTION
48"x24" RECTANGULAR DUCT
RETURN AND FRESH AIR DUCTWORK
RECTANGULAR SUPPLY DUCTWORK
48x24
CONNECTION POINT OF NEW TO EXISTING
EXHAUST DUCTWORK
GENERAL NOTESALL WORK SHALL BE IN ACCORDANCE WITH THE 2018 INTERNATIONAL MECHANICAL CODE, 2009 INTERNATIONAL ENERGY CONSERVATION CODE, AND 2006 SMACNA HVAC DUCT CONSTRUCTION STANDARD. ALL LOCAL CODES OR REQUIREMENTS STILL APPLY.
VISIT SITE PRIOR TO BIDDING. THIS CONTRACTOR SHALL DETERMINE DIFFICULTY OF INSTALLATION AND REFLECT THIS IN HIS BIDDING.
DO NOT SCALE DRAWINGS. SEE ARCHITECTURAL DRAWINGS AND REFLECTED CEILING PLANS FOR EXACT LOCATIONS OF DOORS, WINDOWS, AIR DISTRIBUTION, ETC.
DO NOT SCALE DRAWINGS. THIS CONTRACTOR SHALL VERIFY ALL EXISTING ITEMS AND LOCATIONS IN THE FIELD.
ALL DUCTWORK LOCATIONS SHALL BE COORDINATED WITH WORK UNDER OTHER DIVISIONS OF THE SPECIFICATIONS TO AVOID INTERFERENCE.
WHERE 2’X2’ LAY IN GRILLES ARE SPECIFIED IN HARD CEILINGS, A PLASTER FRAME SHALL BE PROVIDED SO THE GRILLE CAN LAY IN THE CEILING.
EXHAUST DUCTS SHALL BE RIGID SHEET METAL ONLY. FLEXIBLE DUCT SHALL NOT BE USED FOR EXHAUST.
THIS CONTRACTOR SHALL PROVIDE ALL ITEMS OF MISCELLANEOUS STEEL AS REQUIRED FOR INSTALLATION OF ALL MECHANICAL ITEMS.
THIS CONTRACTOR SHALL BE RESPONSIBLE FOR ANY NECESSARY DISMANTLING OF EQUIPMENT TO BE REMOVED.
ITEMS REMOVED UNDER THIS CONTRACT SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND SHALL BE DISPOSED OF PROPERLY.
THIS CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING ALL EXISTING HVACSYSTEMS FROM CONSTRUCTION DEBRIS, DUST AND DIRT FOR THE ENTIRECONSTRUCTION DURATION. DUCT CLEANING AND UNIT/COIL CLEANING SHALL BEPERFORMED AS REQUIRED. PROTECTION SHALL INCLUDE FILTER MEDIA OVER ALLRETURN GRILLES AND RETURN DUCT OPENINGS TO PROTECT DUCTS ANDEQUIPMENT.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
C
B
TAG
A
NECK SIZE
UNI-FLOW SUPPLY
DESCRIPTION
PRICE
MANUFACTURER
ASPD
MODEL
LAY-IN
FRAME
0-125
CFM
6"ø
MAX NC
3024"x24"
FACE SIZE REMARKS
1,2
AIR DISTRIBUTION SCHEDULE
1. PROVIDE WITH STANDARD WHITE FINISH.2. PROVIDE ALUMINUM OR ALUMINIZED STEEL CONSTRUCTION.
PERFORATED EXHAUST PRICE APDDR LAY-IN 0-1000 22"x22" 3024"x24" 1,2
PERFORATED EXHAUST PRICE APDDR LAY-IN 0-100 6"x6" 3012"x12" 1,2
EXHAUST GRILLE; SEE AIRDISTRIBUTION SCHEDULEFOR GRILLE SIZE
SEE ARCHITECTURALDRAWINGS FORCEILING TYPE
SAME SIZE AS GRILLENECK SIZE
RIGID ROUND SHEETMETAL ELBOW
PAINT INSIDE OF PLENUMFLAT BLACK
MIN. 3"
ROUND SHEET METAL RUNOUT DUCT
MANUAL BALANCING DAMPER WITH LOCKING QUADRANT
EXHAUST TRUNK DUCT
INSULATE BACKPAN OF ALL DIFFUSERSAND GRILLES
DIFFUSER (SEE SCHEDULEFOR MODEL AND SIZE)
RIGID ROUND SHEET METALELBOW (INSULATED)
ROUND SHEET METALRUNOUT (INSULATED)
SPIN-IN FITTING WITH 45° EXTRACTORAND MANUAL BALANCING DAMPER WITHSTANDOFF LOCKING QUADRANT (INSULATED)
L.P. SUPPLYTRUNK DUCT(INSULATED)
FLEXIBLE DUCT RUNOUT (SAME SIZEAS DIFFUSER NECK) 8'-0" LONG MAX.
REGISTERED
PROFES
SI O
N A L E N G I N E E R
W I L L I A MC
.LI
VIN
GSTON
SOUTHCA
R OL I N A
No. 1
7994
C E R T I F I C A T EOF
AUT
HORIZATION
SOUTHCA
R OL I N A
SWYG
ERT A
NDAS
SOCIA
TES,
LTD.
NO. C
00227
PROJECT NUMBER
DATETHIS
DRA
WIN
G A
ND T
HE D
ESIG
N SH
OW
N TH
EREO
N AR
E PR
OPE
RTY
OF
STUD
IO 2
LR, I
NC.
THE
REPR
ODU
CTIO
N, C
OPY
ING
, OR
OTH
ER U
SE O
F TH
IS D
RAW
ING
WIT
HOUT
WRI
TTEN
CO
NSEN
T O
F ST
UDIO
2LR
, INC
. IS
PRO
HIBI
TED
AND
INFR
ING
EMEN
TS W
ILL
BE S
UBJE
CT T
O L
EGAL
ACT
ION.
STU
DIO
2LR
, IN
C.
24
28
MA
IN S
TR
EE
TC
OLU
MB
IA, S
C2
92
01
P 8
03
.23
3.6
60
2S
TU
DIO
2LR
.CO
M
CLI
EN
T N
AM
E
PR
OJE
CT
NA
ME
LOC
ATI
ON
SHEET NAME
SHEET NUMBER
C DBA
32
1
C O N S U L T I N G E N G I N E E R S
Swygert & Associates
DBA Swygert & Assoc., Ltd.Post Office Box 11686Columbia, S.C. 29211
Telephone: (803) 791-9300Facsimile: (803) [email protected]
20084
01/29/2021
M201
AH
SS
BLD
G F
IRS
T FL
OO
RR
ES
TRO
OM
RE
NO
VA
TIO
NS
PR
OJE
CT
# H
29-I
364
5000
3418
DETAILS, NOTES,SCHEDULES, & LEGEND
UN
IVE
RS
ITY
OF
SO
UTH
CA
RO
LIN
A A
IKE
N
ISS
UE
D F
OR
BID
DIN
G, J
AN
UA
RY
29,
202
1
AIK
EN
, SO
UTH
CA
RO
LIN
A
1−29−21
NO SCALEEXHAUST GRILLE DETAIL
NO SCALECEILING DIFFUSER DETAIL
REVISIONS
NO. DATE DESCRIPTION
FIRST FLOOR KEY PLAN
CORRIDOR
H101VESTIBULE
V101
WOMEN
115
MEN
118A
JANITOR
114
GENDERNEUTRAL
115A
MEN
105WOMEN
104
ELEV. EQUIP.
E2A
NO WORK THIS AREA
NO WORK THIS AREA
NO WORK THIS AREA
NO WORK THIS AREA NO WORK THIS AREA
NO WORK THIS AREA
NO WORK THIS AREA
NO WORK THIS AREA
NO WORK THIS AREA
NO WORK THIS AREA
ELEC.
E2 ELEC.
E1
T
ELECTRICAL DEMOLITION PLAN - TOILETS 115 AND 118
ELECTRICAL DEMOLITION PLAN - TOILETS 104 AND 105
NO WORK THIS AREA
NO WORK THIS AREA NO WORK THIS AREA
PROJECT NUMBER
DATETHIS
DRA
WIN
G A
ND T
HE D
ESIG
N SH
OW
N TH
EREO
N AR
E PR
OPE
RTY
OF
STUD
IO 2
LR, I
NC.
THE
REPR
ODU
CTIO
N, C
OPY
ING
, OR
OTH
ER U
SE O
F TH
IS D
RAW
ING
WIT
HOUT
WRI
TTEN
CO
NSEN
T O
F ST
UDIO
2LR
, INC
. IS
PRO
HIBI
TED
AND
INFR
ING
EMEN
TS W
ILL
BE S
UBJE
CT T
O L
EGAL
ACT
ION.
STU
DIO
2LR
, IN
C.
24
28
MA
IN S
TR
EE
TC
OLU
MB
IA, S
C
29
20
1P
80
3.2
33
.66
02
S
TU
DIO
2LR
.CO
M
CLI
EN
T N
AM
E
PR
OJE
CT
NA
ME
LOC
ATI
ON
SHEET NAME
SHEET NUMBER
C DBA
32
1
1/7/
2021
9:5
9:59
AM
20084
01/29/2021
IS
SU
ED
F
OR
B
ID
DIN
G, J
AN
UA
RY
2
9, 2
02
1
168 Laurelhurst AvenueColumbia, SC 29210
Midlands Office - Main
[email protected]://www.gwainc.net
(803)252-6919Fax (803)799-5494G
Electrical Engineers
WA
GWA:
inc.
19-3392.01
S
O
U
T
H
C
A
R
O
L
I
N
A
C
E
R
T
I
F
I
C
A
T
E
O
F
A
U
T
H
O
R
I
Z
A
T
I
O
N
S
O
U
T
H
C
A
R
O
L
I
N
A
R
E
G
I
S
T
E
R
E
D
P
R
O
F
E
SS
I
O
N
A
L
E
N
G
IN
E
E
R
S
.
D
I
C
K
S
O
N
O
'
B
R
I
E
N
UN
IVE
RS
ITY
OF
SO
UTH
CA
RO
LIN
A A
IKE
N
AIK
EN
, SO
UTH
CA
RO
LIN
A
AH
SS
BLD
G F
IRS
T FL
OO
RR
ES
TRO
OM
RE
NO
VA
TIO
NS
PR
OJE
CT
# H
29-I
364
5000
3418
ED01
ELECTRICALDEMOLITION PLANS
PROJECT NUMBER
DATETHIS
DRA
WIN
G A
ND T
HE D
ESIG
N SH
OW
N TH
EREO
N AR
E PR
OPE
RTY
OF
STUD
IO 2
LR, I
NC.
THE
REPR
ODU
CTIO
N, C
OPY
ING
, OR
OTH
ER U
SE O
F TH
IS D
RAW
ING
WIT
HOUT
WRI
TTEN
CO
NSEN
T O
F ST
UDIO
2LR
, INC
. IS
PRO
HIBI
TED
AND
INFR
ING
EMEN
TS W
ILL
BE S
UBJE
CT T
O L
EGAL
ACT
ION.
STU
DIO
2LR
, IN
C.
24
28
MA
IN S
TR
EE
TC
OLU
MB
IA, S
C
29
20
1P
80
3.2
33
.66
02
S
TU
DIO
2LR
.CO
M
CLI
EN
T N
AM
E
PR
OJE
CT
NA
ME
LOC
ATI
ON
SHEET NAME
SHEET NUMBER
C DBA
32
1
1/7/
2021
9:5
9:59
AM
20084
01/29/2021
IS
SU
ED
F
OR
B
ID
DIN
G, J
AN
UA
RY
2
9, 2
02
1
168 Laurelhurst AvenueColumbia, SC 29210
Midlands Office - Main
[email protected]://www.gwainc.net
(803)252-6919Fax (803)799-5494G
Electrical Engineers
WA
GWA:
inc.
19-3392.01
S
O
U
T
H
C
A
R
O
L
I
N
A
C
E
R
T
I
F
I
C
A
T
E
O
F
A
U
T
H
O
R
I
Z
A
T
I
O
N
S
O
U
T
H
C
A
R
O
L
I
N
A
R
E
G
I
S
T
E
R
E
D
P
R
O
F
E
SS
I
O
N
A
L
E
N
G
IN
E
E
R
S
.
D
I
C
K
S
O
N
O
'
B
R
I
E
N
UN
IVE
RS
ITY
OF
SO
UTH
CA
RO
LIN
A A
IKE
N
AIK
EN
, SO
UTH
CA
RO
LIN
A
AH
SS
BLD
G F
IRS
T FL
OO
RR
ES
TRO
OM
RE
NO
VA
TIO
NS
PR
OJE
CT
# H
29-I
364
5000
3418
E001
ELECTRICAL NOTES,SCHEDULES, AND DETAILS
AC/MC CABLE DETAIL
LIGHTING FIXTURE SCHEDULE
NOTES TO LIGHTING FIXTURE SCHEDULE
PROJECT NUMBER
DATETHIS
DRA
WIN
G A
ND T
HE D
ESIG
N SH
OW
N TH
EREO
N AR
E PR
OPE
RTY
OF
STUD
IO 2
LR, I
NC.
THE
REPR
ODU
CTIO
N, C
OPY
ING
, OR
OTH
ER U
SE O
F TH
IS D
RAW
ING
WIT
HOUT
WRI
TTEN
CO
NSEN
T O
F ST
UDIO
2LR
, INC
. IS
PRO
HIBI
TED
AND
INFR
ING
EMEN
TS W
ILL
BE S
UBJE
CT T
O L
EGAL
ACT
ION.
STU
DIO
2LR
, IN
C.
24
28
MA
IN S
TR
EE
TC
OLU
MB
IA, S
C
29
20
1P
80
3.2
33
.66
02
S
TU
DIO
2LR
.CO
M
CLI
EN
T N
AM
E
PR
OJE
CT
NA
ME
LOC
ATI
ON
SHEET NAME
SHEET NUMBER
C DBA
32
1
1/7/
2021
9:5
9:59
AM
20084
01/29/2021
IS
SU
ED
F
OR
B
ID
DIN
G, J
AN
UA
RY
2
9, 2
02
1
168 Laurelhurst AvenueColumbia, SC 29210
Midlands Office - Main
[email protected]://www.gwainc.net
(803)252-6919Fax (803)799-5494G
Electrical Engineers
WA
GWA:
inc.
19-3392.01
S
O
U
T
H
C
A
R
O
L
I
N
A
C
E
R
T
I
F
I
C
A
T
E
O
F
A
U
T
H
O
R
I
Z
A
T
I
O
N
S
O
U
T
H
C
A
R
O
L
I
N
A
R
E
G
I
S
TE
R
E
D
P
R
O
F
E
SS
I
O
N
A
L
E
N
G
IN
E
E
R
S
.
D
I
C
K
S
O
N
O
'
B
R
I
E
N
UN
IVE
RS
ITY
OF
SO
UTH
CA
RO
LIN
A A
IKE
N
AIK
EN
, SO
UTH
CA
RO
LIN
A
AH
SS
BLD
G F
IRS
T FL
OO
RR
ES
TRO
OM
RE
NO
VA
TIO
NS
PR
OJE
CT
# H
29-I
364
5000
3418
E002
ELECTRICAL NOTES,SCHEDULES, AND DETAILS
FIRST FLOOR KEY PLAN
VESTIBULE
V101
WOMEN
115
MEN
118A
JANITOR
114
GENDERNEUTRAL
115A
MEN
105WOMEN
104
ELEV. EQUIP.
E2A
NO WORK THIS AREA
NO WORK THIS AREA
NO WORK THIS AREA
NO WORK THIS AREA NO WORK THIS AREA
NO WORK THIS AREA
NO WORK THIS AREA
NO WORK THIS AREA
NO WORK THIS AREA
NO WORK THIS AREA
NO WORK THIS AREA
ELEC.
E2 ELEC.
E1
T
ELECTRICAL PLAN - TOILETS 115 AND 118 - NEW WORK
JANITOR
114
MEN
118
WOMEN
115
GENDERNEUTRAL
115A
ELECTRICAL PLAN - TOILETS 104 AND 105 - NEW WORK
MEN
105WOMEN
104
ELEV. EQUIP.
E2A
ELEC.
E2ELEC.
E1
NO WORKTHIS AREA
NO WORKTHIS AREA
NO WORKTHIS AREA
COT ROOM
104A
PROJECT NUMBER
DATETHIS
DRA
WIN
G A
ND T
HE D
ESIG
N SH
OW
N TH
EREO
N AR
E PR
OPE
RTY
OF
STUD
IO 2
LR, I
NC.
THE
REPR
ODU
CTIO
N, C
OPY
ING
, OR
OTH
ER U
SE O
F TH
IS D
RAW
ING
WIT
HOUT
WRI
TTEN
CO
NSEN
T O
F ST
UDIO
2LR
, INC
. IS
PRO
HIBI
TED
AND
INFR
ING
EMEN
TS W
ILL
BE S
UBJE
CT T
O L
EGAL
ACT
ION.
STU
DIO
2LR
, IN
C.
24
28
MA
IN S
TR
EE
TC
OLU
MB
IA, S
C
29
20
1P
80
3.2
33
.66
02
S
TU
DIO
2LR
.CO
M
CLI
EN
T N
AM
E
PR
OJE
CT
NA
ME
LOC
ATI
ON
SHEET NAME
SHEET NUMBER
C DBA
32
1
1/7/
2021
9:5
9:59
AM
20084
01/29/2021
IS
SU
ED
F
OR
B
ID
DIN
G, J
AN
UA
RY
2
9, 2
02
1
168 Laurelhurst AvenueColumbia, SC 29210
Midlands Office - Main
[email protected]://www.gwainc.net
(803)252-6919Fax (803)799-5494G
Electrical Engineers
WA
GWA:
inc.
19-3392.01
S
O
U
T
H
C
A
R
O
L
I
N
A
C
E
R
T
I
F
I
C
A
T
E
O
F
A
U
T
H
O
R
I
Z
A
T
I
O
N
S
O
U
T
H
C
A
R
O
L
I
N
A
R
E
G
I
S
TE
R
E
D
P
R
O
F
E
SS
I
O
N
A
L
E
N
G
IN
E
E
R
S
.
D
I
C
K
S
O
N
O
'
B
R
I
E
N
UN
IVE
RS
ITY
OF
SO
UTH
CA
RO
LIN
A A
IKE
N
AIK
EN
, SO
UTH
CA
RO
LIN
A
AH
SS
BLD
G F
IRS
T FL
OO
RR
ES
TRO
OM
RE
NO
VA
TIO
NS
PR
OJE
CT
# H
29-I
364
5000
3418
E100
ELECTRICAL PLANS -NEW WORK