![Page 1: Floor Warming. 2 RaySol System 3 RaySol Applications Freezer Frost Heave Prevention Concrete Floor Warming Heat Loss Replacement Tile and Marble Floor](https://reader035.vdocument.in/reader035/viewer/2022062421/56649dc65503460f94aba500/html5/thumbnails/1.jpg)
Floor Warming
![Page 2: Floor Warming. 2 RaySol System 3 RaySol Applications Freezer Frost Heave Prevention Concrete Floor Warming Heat Loss Replacement Tile and Marble Floor](https://reader035.vdocument.in/reader035/viewer/2022062421/56649dc65503460f94aba500/html5/thumbnails/2.jpg)
2
RaySol System
![Page 3: Floor Warming. 2 RaySol System 3 RaySol Applications Freezer Frost Heave Prevention Concrete Floor Warming Heat Loss Replacement Tile and Marble Floor](https://reader035.vdocument.in/reader035/viewer/2022062421/56649dc65503460f94aba500/html5/thumbnails/3.jpg)
3
RaySol Applications
•Freezer Frost Heave Prevention
•Concrete Floor Warming
•Heat Loss Replacement
•Tile and Marble Floor Warming
![Page 4: Floor Warming. 2 RaySol System 3 RaySol Applications Freezer Frost Heave Prevention Concrete Floor Warming Heat Loss Replacement Tile and Marble Floor](https://reader035.vdocument.in/reader035/viewer/2022062421/56649dc65503460f94aba500/html5/thumbnails/4.jpg)
4
Tile and Marble Floor Warming
•Application Overview
– Not primary heat source - comfort heat
– Residential bathrooms
– Embedded in mortar under tile
– Low density concrete
(Gypcrete) often used
![Page 5: Floor Warming. 2 RaySol System 3 RaySol Applications Freezer Frost Heave Prevention Concrete Floor Warming Heat Loss Replacement Tile and Marble Floor](https://reader035.vdocument.in/reader035/viewer/2022062421/56649dc65503460f94aba500/html5/thumbnails/5.jpg)
5
Heat Loss Replacement
•Application Overview
– Used in areas over unheated space such as parking garage
– Objective is to have net zero heat flux
– Run in conduit or attached to bottom of floor
![Page 6: Floor Warming. 2 RaySol System 3 RaySol Applications Freezer Frost Heave Prevention Concrete Floor Warming Heat Loss Replacement Tile and Marble Floor](https://reader035.vdocument.in/reader035/viewer/2022062421/56649dc65503460f94aba500/html5/thumbnails/6.jpg)
6
Concrete Floor Warming
•Application overview
– Not primary heat source - comfort heat
– Schools, gymnasiums, bathrooms
– Run in conduit
![Page 7: Floor Warming. 2 RaySol System 3 RaySol Applications Freezer Frost Heave Prevention Concrete Floor Warming Heat Loss Replacement Tile and Marble Floor](https://reader035.vdocument.in/reader035/viewer/2022062421/56649dc65503460f94aba500/html5/thumbnails/7.jpg)
7
Frost Heave Prevention
•Application Overview
– Moisture in ground under cold storage areas (<32 degrees) freezes forcing up floors
– Insulation slows, but does
not prevent, freezing
![Page 8: Floor Warming. 2 RaySol System 3 RaySol Applications Freezer Frost Heave Prevention Concrete Floor Warming Heat Loss Replacement Tile and Marble Floor](https://reader035.vdocument.in/reader035/viewer/2022062421/56649dc65503460f94aba500/html5/thumbnails/8.jpg)
8
RaySol Installation Methods
• Embedded in mortar
• In conduit embedded in concrete
• In conduit embedded in subsoil
• Attached to the bottom of concrete floor
![Page 9: Floor Warming. 2 RaySol System 3 RaySol Applications Freezer Frost Heave Prevention Concrete Floor Warming Heat Loss Replacement Tile and Marble Floor](https://reader035.vdocument.in/reader035/viewer/2022062421/56649dc65503460f94aba500/html5/thumbnails/9.jpg)
9
Tyco Thermal Controls Solution
• Self-regulating heating cable– RaySol 1 and RaySol 2
• Components– FTC-XC, FTC-P -- Power connections
– RayClic-E -- End Seal
• Design Software– Automated design guide (RS-ADG)
• Literature
– Design guide
– Installation and operation manual
– Installation instructions
![Page 10: Floor Warming. 2 RaySol System 3 RaySol Applications Freezer Frost Heave Prevention Concrete Floor Warming Heat Loss Replacement Tile and Marble Floor](https://reader035.vdocument.in/reader035/viewer/2022062421/56649dc65503460f94aba500/html5/thumbnails/10.jpg)
10
Define the Application
•Each section of the design Guide is a Unit
![Page 11: Floor Warming. 2 RaySol System 3 RaySol Applications Freezer Frost Heave Prevention Concrete Floor Warming Heat Loss Replacement Tile and Marble Floor](https://reader035.vdocument.in/reader035/viewer/2022062421/56649dc65503460f94aba500/html5/thumbnails/11.jpg)
11
Select the Heating Cable Spacing
•Use the proper table to select spacing and determine amount of heating cable required.
![Page 12: Floor Warming. 2 RaySol System 3 RaySol Applications Freezer Frost Heave Prevention Concrete Floor Warming Heat Loss Replacement Tile and Marble Floor](https://reader035.vdocument.in/reader035/viewer/2022062421/56649dc65503460f94aba500/html5/thumbnails/12.jpg)
12
Heating Cable Layout
•Determine the heating cable and component layout for your application.
![Page 13: Floor Warming. 2 RaySol System 3 RaySol Applications Freezer Frost Heave Prevention Concrete Floor Warming Heat Loss Replacement Tile and Marble Floor](https://reader035.vdocument.in/reader035/viewer/2022062421/56649dc65503460f94aba500/html5/thumbnails/13.jpg)
13
Design the Electrical System
•Use the maximum circuit length to determine the number of circuits required.