Page 1 of 25
व्यावसाययक परीक्षण यरपोर्ट Z सखं्या@ No.: IMP-453/866
COMMERCIAL TEST REPORT माह:@ Month: June, 2018
GREAVES GCRT 175M ROTAVATOR
(Tractor Mounted, PTO Operated)
भारत सरकार Government of India
कृयष एवं यकसान कल्याण मंत्रालय
Ministry of Agriculture and Farmers Welfare
कृयष, सहकायरता एवं यकसान कल्याण यवभाग Department of Agriculture, Cooperation and Farmers Welfare
दयक्षणी के्षत्र कृयष मशीनरी प्रयशक्षण एवं परीक्षण संस्थान Southern Region Farm Machinery Training and Testing Institute
ट्रैक्र्र नगर, गालटयदने्न - 515 731, यिला: अनंतपुर (आं. प्र.) Tractor Nagar, Garladinne- 515 731, District: Anantapur (A.P.)
[An ISO 9001:2015 CERTIFIED INSTITUTE]
Website: http://srfmtti.dacnet.nic.in/
E-mail: [email protected] Tele./FAX: 08551-286441
IMP-
453/866
GREAVES GCRT 175M ROTAVATOR
(Tractor Mounted, PTO Operated) Commercial
SOUTHERN REGION FARM MACHINERY TRAINING & TESTING INSTITUTE -
ANANTAPUR [An ISO 9001:2015 CERTIFIED INSTITUTE]
Page 2 of 25
GREAVES GCRT 175M ROTAVATOR
Report No. : IMP-453/866 Month: JUNE Year: 2018
Government of India
Ministry of Agriculture and Farmers Welfare
Department of Agriculture, Cooperation and Farmers Welfare
Southern Region Farm Machinery Training and Testing Institute
Tractor Nagar, Garladinne-515 731, District: Anantapur (A.P.)
[An ISO 9001:2015 CERTIFIED INSTITUTE]
Telephone: 08551-286441 Fax: 08551-286441
Website: http://srfmtti.dacnet.nic.in/ E-mail: [email protected]
Manufacturer
:
M/s. Osaw Udyog,
Village Manglai, P.O. Khuda Kallan,
Jagadhri Road, Ambala,
Haryana - 133 004, India.
Applicant : M/s. Greaves Cotton Ltd.,
Plot No.72, SIPCOT Industrial Complex,
Ranipet – 632 403, Vellore District,
Tamilnadu, India.
IMP-
453/866
GREAVES GCRT 175M ROTAVATOR
(Tractor Mounted, PTO Operated) Commercial
SOUTHERN REGION FARM MACHINERY TRAINING & TESTING INSTITUTE -
ANANTAPUR [An ISO 9001:2015 CERTIFIED INSTITUTE]
Page 22 of 25
9. EASE OF OPERATION & ADJUSTMENTS
No difficulty was observed during the operation and adjustment of rotavator.
10. DEFECTS, BREAKDOWNS AND REPAIRS
No defect/breakdown and repair was occurred during entire period of field
& lab tests.
11. SUMMARY OF OBSERVATIONS, COMMENTS AND
RECOMMENDATION
11.1 No ingress of dust and water/mud in primary reduction gear box,
secondary reduction gear box, and rotary axle bearing cap was
observed.
11.2 Provisions for breather cap and oil level dipstick in primary and secondary
gearbox are provided.
11.3 Parking stand & safety device are provided in rotavator.
11.4 The specification of implement hitch is not conforming in full to the IS 4468
(Pt-I):1997.
11.5 Dimensions of PIC yoke is conforming where as PIC is not conforming to IS
4931:1995. This should be looked into for corrective action.
11.6 The hardness of rotor blades at edge and shank portion do not meet, the
requirement of IS 6690:1981. This should be looked into for corrective
action.
11.7 Carbon & Manganese content of rotor blades do not meet the requirement of
IS 6690:1981. This should be looked into for corrective action.
11.8 Most of parameters of labeling plate are declared as per IS requirement.