8/8/2019 Handouts Quality Control and Quality Assurance for Antibiotic Testing
1/27
-
8/8/2019 Handouts Quality Control and Quality Assurance for Antibiotic Testing
2/27
date zone size (mm)
23-Jan-10 23
24-Jan-10 27
25-Jan-10 26
26-Jan-10 25
27-Jan-10 25
28-Jan-10 24
29-Jan-10 24
30-Jan-10 26
31-Jan-10 271-Feb-10 29
2-Feb-10 29
3-Feb-10 23
4-Feb-10 23
5-Feb-10 22
6-Feb-10 23
7-Feb-10 238-Feb-10 22
9-Feb-10 22
10-Feb-10 23
11-Feb-10 23
12-Feb-10 22
date zone size (mm)
1-Jan-10 25
2-Jan-10 243-Jan-10 25
4-Jan-10 24
5-Jan-10 26
6-Jan-10 24
7-Jan-10 27
8-Jan-10 25
9-Jan-10 2610-Jan-10 27
11-Jan-10 27
12-Jan-10 26
13-Jan-10 28
14-Jan-10 23
15-Jan-10 24
16-Jan-10 27
17-Jan-10 26
18-Jan-10 26
19-Jan-10 28
20-Jan-10 25
21-Jan-10 25
22-Jan-10 24
Quiz: anything unusual about
QC zone sizes? QC ATCC
25923 (Saureus) with
Cefoxitin disc
(FOX)
CLSI: zone size
within 22-29mm
-
8/8/2019 Handouts Quality Control and Quality Assurance for Antibiotic Testing
3/27
Quality Control and QualityAssurance for Antibiotic Testing
22 Sep 2010
Microbiology Technical Workshop
-
8/8/2019 Handouts Quality Control and Quality Assurance for Antibiotic Testing
4/27
Introduction
Various standards
eg CLSI, CDS
Various methods
Eg disc susceptibility, microbroth dilution Follow QC instructions as stated
-
8/8/2019 Handouts Quality Control and Quality Assurance for Antibiotic Testing
5/27
Introduction (2)
Some general principles apply:
1. Materials and Procedures : strictly adhere to2. Able to detect abnormalities and take
necessary corrective actions
-
8/8/2019 Handouts Quality Control and Quality Assurance for Antibiotic Testing
6/27
Materials & Procedures
General: Expiry date & storage
conditions manufacturersrecommendation
1. Media:
sterility
Support growth
Does not interfere with activity of antibiotics
-
8/8/2019 Handouts Quality Control and Quality Assurance for Antibiotic Testing
7/27
-
8/8/2019 Handouts Quality Control and Quality Assurance for Antibiotic Testing
8/27
Materials & Procedures (3)
Perform and interpret correctly
Technologists : adequately trained
-
8/8/2019 Handouts Quality Control and Quality Assurance for Antibiotic Testing
9/27
Detect Errors / Corrective actions
Documentation
Useful for monitoring / troubleshooting futureQC failures
CAP requirements
-
8/8/2019 Handouts Quality Control and Quality Assurance for Antibiotic Testing
10/27
What to do when QC is out
CLSI recommendations:
ID cause
Cause found repeat x 01
Repeat ok = case close
Repeat out of range repeat
No obvious
cause
5 consecutive days
All within range= case close
1 out ofrange
Re-examine
-
8/8/2019 Handouts Quality Control and Quality Assurance for Antibiotic Testing
11/27
Common sources of error
Media Storage
Thickness
Contamination
pH
Wrong media
Antibiotics
Storage Wrong disc
QC strains Wrong strains
Inoculum
Storage
Contamination
Old cultures
Procedures
Incubation conditions Disc placement
transcription
-
8/8/2019 Handouts Quality Control and Quality Assurance for Antibiotic Testing
12/27
Other Tools
Control charts and Westgard rules
CUSUM
-
8/8/2019 Handouts Quality Control and Quality Assurance for Antibiotic Testing
13/27
date zone size (mm)
b
-
8/8/2019 Handouts Quality Control and Quality Assurance for Antibiotic Testing
14/27
Control Chart ATCC 25923 SAU with FOX
20
21
22
23
24
25
26
27
28
29
30
1-Ja
n-1
0
3-Ja
n-1
0
5-Ja
n-1
0
7-Ja
n-1
0
9-Ja
n-1
0
11-Jan-1
0
13-Jan-1
0
15-Jan-1
0
17-Jan-1
0
19-Jan-1
0
21-Jan-1
0
23-Jan-1
0
25-Jan-1
0
27-Jan-1
0
29-Jan-1
0
31-Jan-1
0
2-Feb-1
0
4-Feb-1
0
6-Feb-1
0
8-Feb-1
0
10-Feb-1
0
12-Feb-1
0
date
1-Feb-10 29
2-Feb-10 29
3-Feb-10 23
4-Feb-10 23
5-Feb-10 22
6-Feb-10 23
7-Feb-10 238-Feb-10 22
9-Feb-10 22
10-Feb-10 23
11-Feb-10 23
12-Feb-10 22
-
8/8/2019 Handouts Quality Control and Quality Assurance for Antibiotic Testing
15/27
Warning rules
Warning 11112SD2SD2SD2SD : It is violated if the IQC value exceeds the
mean by 2SD. It is an event likely to occur normally in less
than 5% of cases.
Warning 22222SD2SD2SD2SD : It detects systematic errors and is violatedwhen two consecutive IQC values exceed the mean on the
same side of the mean by 2SD.
Warning 44441SD1SD1SD1SD : It is violated if four consecutive IQC valuesexceed the same limit (mean 1SD) and this may indicate the
need to perform instrument maintenance or reagent
calibration.
-
8/8/2019 Handouts Quality Control and Quality Assurance for Antibiotic Testing
16/27
Mandatory rules
Mandatory 11113SD3SD3SD3SD : It is violated when the IQC value exceeds
the mean by 3SD. The assay run is regarded as out of
control.
Mandatory RRRR4SD4SD4SD4SD : It is only applied when the IQC is tested induplicate. This rule is violated when the difference in SD
between the duplicates exceeds 4SD.
Mandatory 10x10x10x10x : This rule is violated when the last 10consecutive IQC values are on the same side of the mean or
target value.
-
8/8/2019 Handouts Quality Control and Quality Assurance for Antibiotic Testing
17/27
Scenario 1
New lot / new antibiotics
How frequently should you QC?
-
8/8/2019 Handouts Quality Control and Quality Assurance for Antibiotic Testing
18/27
Scenario 2
Check
Media Antibiotics
QC organism Procedure
-
8/8/2019 Handouts Quality Control and Quality Assurance for Antibiotic Testing
19/27
Scenario 1
New antibiotic introduced
CLSI Test for 30 consecutive days
If no more 3 (out of 30) are outsideacceptable range - convert to weekly testing
-
8/8/2019 Handouts Quality Control and Quality Assurance for Antibiotic Testing
20/27
Scenario 2
7 Oct 2009 - QC ATM 20mm (expected
23-29mm) What would you do?
-
8/8/2019 Handouts Quality Control and Quality Assurance for Antibiotic Testing
21/27
Scenario 2
Repeat testing performed by same staff
Correct QC organism, media, procedure,incubation, interpretation
Wrong inoculum - too heavy
-
8/8/2019 Handouts Quality Control and Quality Assurance for Antibiotic Testing
22/27
Scenario 3
14 Oct 2008
Vitek Gram positive panel QC Multiple drugs MIC - resistant
Expected - sensitive
-
8/8/2019 Handouts Quality Control and Quality Assurance for Antibiotic Testing
23/27
Scenario 3
Purity plate - contaminated with other
organisms
-
8/8/2019 Handouts Quality Control and Quality Assurance for Antibiotic Testing
24/27
Scenario 4
QC Vitek Gram positive panel
Multiple antibiotics - resistant Expected - sensitive
-
8/8/2019 Handouts Quality Control and Quality Assurance for Antibiotic Testing
25/27
Scenario 4
Test repeated
With organism from purity plate (prev run)- resistant
And separate set from weekly QC plate -sensitive
Wrong ATCC used.
-
8/8/2019 Handouts Quality Control and Quality Assurance for Antibiotic Testing
26/27
-
8/8/2019 Handouts Quality Control and Quality Assurance for Antibiotic Testing
27/27
Quality assurance
Education
External Proficiency test, eg CAP Literature and publications
Accreditation