Heavy Duty Motor StartersMelting Alloy Overload, Manual Reset Class 14
Selection
Ordering Instructions
>• Use complete catalog number Replace the (*) with letter from thecoil table. Dual voltage coils are wired on high voltage unless specifiedon order.
*• Order heater elements by code number at $9 each page 870.*• For bimetal overload add "81" to Cat No to create a new base style.
("8" for single phase). Example: 14DP32A*81. Price same as melting alloy.> Field Modification Kits pages 116-120. Factory Modifications
pages 121-125.*• For 380 Volt 50 Hertz information see page 129.> Dimensions see pages 133-135.*• Wiring Diagrams see page 150.
Coil Table
60Hz Voltage Letter
24 Separate Control
120 Separate Control
110-120/220-240®
200-208
220-240
277220-240/440-480®
440-480
550-600
JFADGLCHE
For other voltages and frequencies
see Factory Modifications page 124.
3 Phase, 3 Pole (For Bimetal Overload see Ordering Instructions)
Max Hp
200Volts
11/3TA
1010152530405075
150
—
230Volts
1/2
37'/
10152030405075
100200300450
460Volts
25
101525305075
100LJ50
200400BOO900
575Voits
25
101525305075
100150200400600900
CantAmpRating
9182740456090
115135210270540810
1215
NEMASize
0001
—2
—
3—
4—
5678
HalfSize
——
13/4
—
2'/Z
—
y/i—W:
————
Enclosure
Open Type
Catalog No
14BG32A*
14CP32A*
14DP32A*
14EP32A"
14FP32A*
14GP32A*
14HP32A*
14IP32A*
14JG32A*
PriceS
162.
204.
234.
324.
426.
558.
690.
1338.
1578.
NEMA1General Purpose
Catalog No
14BG32B*
14CP32B*
14DP32B*
14EP32B*
14FP32B*
14GP32B*
14HP32B*
14IP32B*
14JG32B*
PriceS
174.
216.
246.
336.
486.
648.
810.
1590.1830.
NEMA 4/4XWatertight, DusttightCorrosion Resistant304 Stainless Steel®
Catalog No
Use Size 0
14CP32W*
14DP32W*
14EP32W*
14FP32W*
14GP32W*
14HP32W"
14IP32W*
14JG32W*
PriceS
—426.
462.
552.
918.
1170.
1422.2634.
2874.
NEMA 7 & 9NEMA 3 & 4Class I Groups C & DClass II Groups E, F & GBolted EnclosuresIndoor/Outdoor Use
Catalog No PriceS
ESP1 00 Solid State
Overload Standard.
see page 58 for
selection.
NEMA 12NEMA 3/3R®Industrial UseWeatherproof
Catalog No
Use Size 0
14CP320*
14DP320*
14EP320*
14FP320*
14GP320*
14HP320*
14IP320*
14JG320*
PriceS
—288.
318.
408.
618.
792.
966.
2106.2346.
ESP100 Solid State Overload Standard, see page 58 for selection
Single Phase, 2 Pole (For Bimetal Overload see Ordering Instructions)
Max Hp
115Volts
12335
230Volts
12357/7
10
ContAmpRating
91827354560
NEMASize
0001IP2
HalfSize
———
U
Enclosure
Open Type
Catalog No
14BG12A*
14CP12A*
14DP12A*
14EP12A*
14FP12A*
14GP12A*
Price S
141.
183.
213.
279.
387.
525.
NEMA1General Purpose
Catalog No
14BG12B*
14CP12B*
14DP12B*
14EP12B*
14FP12B*
14GP12B*
PriceS
153.
195.
225.
291.
447.
609.
NEMA 4/4XWatertight, DusttightCorrosion Resistant304 Stainless Steel®
Catalog No
Use Size 0
14CP12W*
14DP12W*
14EP12W*
14FP12W*
14GP12W"
PriceS
—
405.
441.
507.
879.
1131.
NEMA 7 & 9Class 1 Groups C & DClass II Groups E, F & GBolted EnclosuresIndoor/Outdoor Use
Catalog No PriceS
ESP1 00 Solid State
Overload Standard,
see page 58 for
selection
NEMA 12NEMA 3/3R 'ndustrial Use
Weatherproof
Catalog No
Use Size 0
14CP120*
14DP120*
14EP120*
14FP120"
14GP120*
PriceS
—
267.
297.
363.
579.
759.
CDDual Voltage NA on Size 00.
60
©For NEMA 4X fiberglass enclosure change 7th characterof Cat No to F. Example: 14DP32F*. Price addition seepage 123. Available through Size 4.
©To order Starter Size 0-13/4 in NEMA 3/3R enclosurechange 7th character of catalog number to D. Example:14DP32D*. Price same as NEMA 12. For all other sizessee page 119.
Discount Schedule AC-10 (FURN)Siemens & Furnas Control Products
^^
.21as 03U V)
General InformationNorth American Approvals
General.INSTALLATION CONSIDERATIONSThe control products described in this cata-log have been designed, tested and manu-factured in accordance with a wide variety ofstandards including but not limited to thoseissued by UL, CSA, NEMA and IEC. Thesestandards typically apply to the control prod-uct as a component and not the installationor use of the product. It is the responsibilityof the end user of the control product tomake sure each installation complies with allof the applicable safety requirements, laws,regulations, codes and standards (someexamples of which are the N.E.C., the C.E.C.
and OSHA regulations). Note that localauthorities may impose further jurisdictionover each installation. When in doubt, con-sult with the local inspection authorities.Unless otherwise specified, the control prod-ucts described in this catalog are designedto operate under "usual service conditions"as defined in NEMA Standards Publication—Part ICS 1-108. Open type devices areintended for installation in enclosures thatprovide environmental protection as neededfor the specific application. See page 14 fordefinitions of the various enclosure types.
PERFORMANCE DATAWhere given in this catalog, performancedata should only be used as a guide to deter-mine the suitability of the product for anapplication. The data may be the result ofaccelerated testing or elevated stress levelsunder controlled conditions. The user musttake care in correlating this data to actualapplication or service conditions.UL and CSA—File Numbers and GuideCard Numbers
Most control equipment listed in this catalog isdesigned, manufactured and tested in accor-dance with the relevant UL and CSA standardsas listed in the table below.
12
Siemens Brand DevicesDescription
3TH2Control Relays 3TH3
3TH8Solid-state timersAC contactors, DC contactorsReversing StartersOverload relaysTerminal blocksManual Motor Controller 3VUCam Switch 3LB. 3LCStarters, Combination Starters
Push buttons
Lighting and Heating ContactorsMechanical Limit Switches
International StyleNorth American Style
Fast Bus Components/KitsModular Motor Controllers Type EModular Motor Controllers —
Group InstallationUS Series StarterFraction Hp Starters. SMF, MMS
Furnas Brand DevicesClass
11,12Danms Switches14,22.30,40,43Starters and Contactors17,18,25,26,32Combination Starters36,37Reduced Voltage Starters83, 84, 85, 87, 88Pump Control Panels50Standard Duty Pilot Devices51Hazardous Location Pilot Devices5230 mm Pilot Devices16 ,41 ,42 .45Definite Purpose Controls46,47Relays48, 948, 958Overload Relays49Field KitsClass 56Fast SwitchClass 53Master SwitchClass 69Pressure Switch
iGuide No File No
r LR 12730LR 50487
Class 3211 LR 12730Class 3211 LR 12730Class 3211 LR 38590Class 3211 LR 12730Class 3211 LR 50181Class 3211 LR 50487Class 3211 LR 12730Class 3211 LR 38590
Class 3211 LR 12730
Class 3231 LR 38590
Class 3211 LR 50487Class 3211 LR 68551
Class 3211 LR 50487
Class 3211 LR 38590— —
®Guide No File No
NKCR E 44653
NKCR E 44653NLDX E 31519NLDX E 32529NKCR E 44653
NLVR E 47705NLRV E 47705NLDX E 32529
ISNRNT E 60310
NKCR E 44653NKCR E 47512NMTR E 155959NKJH E 156943
NLRV E 47705
NLDX E 32529— —
91
Guide No File No
NKCR2 E 44653
NLDX2 E 31519— —NKCR2 E 44653XCFR2 E 80027— —
— —
— —
— —
NKCR2 E 44653
NMTR2 E 160776— —
— —
NLRV2 E 80332
@Guide No File No
Class 3211 LR6535
Class 3211 LR6535
Class 3211 LR6535
Class 3211 LR6535
Class 3211 LR6535
Class 3211 LR6535
Class 321 8 LR 23889
Class 321 1 LR 6535
Class 3211 LR6535
Class 3211 LR6535
Class 3211 LR6535
Class 3211 ELR535
Class 3211 LR6535
Class 3211 LR6535
Class 3211 LR6535
®Guide No File No
NLRV E 10590
NLDX E 14900
NKJH E 185287
NLDX E 14900
NKJH E 185287
NKCR E 22655
NOIV E 39935
NKCR E 22655
— —
NKCR E 22655
NKCR E 22655
NLDX E 14900
NLRV E 10590
NKCR E 22655
NKPZ E l 4861
91
Guide No File No
NLRV2 E 10590
NLDX2 E 14900
— —
NLDX2 E 14900
— —
— —
— —
NKCR2 E 22655
NLDX2 E 14900
NKCR2 E 22655
NKCR2 E 22655
NLDX2 E 14900
— —
— —
NKPZ2 E 14861
Siemens & Furnas Control Products •
NEMA & HP Rated Control Contents
Contents — NEMA ControlManual Starters and SwitchesFractional HP Class SMFHeater Elements Class SMFManual Switches Class MMS, MRS . .Manual Switches Class 12
NEMA Manual Starters and SwitchesHeavy Duty Class 11
Drum ControllersClass 5 8 . .
Pages
.29-30. . . . 3 1.32-34
. 35
.38-40
.41-47
NEMA Full Voltage StartersProduct OverviewInnova"" NEMA Catalog Numbering SystemCompetitive Cross ReferenceUS Series to Innova™ Cross ReferenceNon-Reversing NEMA Starters, Class 14Reversing NEMA Starters, Class 22Multi Speed NEMA Starters, Class 30Dimensions, Class 14
Class 22Class 30
Wiring Diagrams, Class 14Class 22Class 30
Combination NEMA StartersDisconnect Type, Class 17Disconnect Type, Fusible, Class 17Circuit Breaker Type, Class 18Reversing Disconnect Type, Class 25Reversing Circuit Breaker Type, Class 26Combination Multi Speed NEMA Starters, Class 32Dimensions, Class 17, 18
Class 25, 26Class 32
Wiring Diagrams, Class 17,18Class 25, 26Class 32
Field KitsFactory ModificationsTechnical Information
Reduced Voltage NEMA StartersAuto Transformer Starter Class 36, 37Part Winding Starter Class 36, 37Wye Delta Open Transition Class 36, 37Wye Delta Closed Transition Class 36, 37Enclosure ModificationsReduced Voltage Starter KitsDimensions, Class 36, 37Wiring Diagrams, Class 36, 37Field KitsFactory ModificationsTechnical Information
Solid State Reduced Voltage StartersClass 70, 71 Non Combination and Combination .
. .48-515253
. . 54-57
. . 58-60
. . 71-72
. . 77-83132-135139-141139, 144149-150. . . . 1 5 2
. 154
. .61-63
. . 64-66
. . 67-70
. . 73-74
. . 75-76
. . 84-95136-138142-143. . . . 145. . . . 1 5 1. . . . 1 5 3. . . . 154116-120121-125126-131
. . 96, 99
. 97, 100
. 98, 101
. 98, 102
. ... 103104-107. ... 146155-157116-120121-125126-131
108-1 1 1
NEMA Full Voltage ContactorsNon Reversing Contactor, Class 40Vacuum Contactor, Class 49Reversing Contactor, Class 43. .. .Dimensions, Class 40
Class 43Vacuum Contactor, Class 49
Wiring Diagrams, Class 40Class 43
Field KitsFactory ModificationsTechnical Information
NEMA Controls ModificationsEnclosure KitsField Modification KitsFactory Modifications
. . . . 112-113112114
134, 135, 147140, 141, 148
130
158158
. . . . 116-120
. . . . 121-125. 126-131
. ... 115116-120121-125 3D
s%°-sg»f£
Siemens & Furnas Control Products
m%> Heavy Duty StartersSize 0-4 Starter Features, Application
General
Size 0-13/4ESP100 Solid State Starter
ESP100 Solid State Overload RelaysThese standard features of the ESP100provide Extra Starter Performance.
• True phase loss protection; tripswithin 3 seconds.
• High accuracy trip curves; ± 2%repeat trip accuracy.
• Ease of use. Mount, wire, and set FLA.• Overload is self protected against
short circuits.• Overload is self powered and
requires no hard wiring or separatepower source.
• Simple, versatile adjustment; mini-mum of 2:1 FLA adjustment range.(4:1 in lower FLA ranges.)
• Heaterless construction minimizesenergy costs and the costs of cabinetventilation or cooling.
• Class 20 protection is standard. Class10 and 30 protection are available.
• Provides motor protection for50/60 Hertz.
ESP100 starters combine the ruggedcharacteristics of a NEMA rated con-tactor with a solid state overload whichprovides phase loss protection. Itoffers the industrial user greater pro-tection and added life for motors inheavy duty applications. The inherentbenefits of the ESP100 result in costsavings as well.
Self-Reset Version
The self-reset starter is ideal forcranes, hoists, and other applicationswhere the controls are mounted in aremote location that may be difficult toaccess. The NC overload contactopens for a short duration (50-75msec) on an overload or phase losscondition. The unit provided can beapplied in one of three ways:1. Three wire control circuit usingFurnas Size 0-4 contactor. The self-reset overload can be retrofitted andapplied in a three wire control applica-tion as a remote reset overload with-out additional components or wiring.2. PLC—(assuming initiating starter coilvia PLC) Timers and counters can beused to determine time betweenrestarts and maximum number ofrestarts.3. Use NC overload contact to drop outa control relay. See page 475 for wiringdiagrams.
ESP100 FLA Adjustment Dial-FLA of the motor.
-Set the adjustment dial on the overload to the
Figure 1
MELTING ALLOVHEATERSCORRESPONDINGTO DIAL SETTING
Typical Solid-State Over loadAdjustment Dial Markings
Each overload is precisely cal ibrated andlabels are individually laser printed andthen custom applied for each particularcalibration.
Typical Number of Heater ElementsNeeded for Alloy Overloads
• No need for heater coi lselection or installation.
• No heater elements to stock.• More precision.
Size 0-1%Melting Alloy Starter
Melting Alloy starters are standard.Together with the proper heater ele-ments, these starters help to provide pro-tection to motor windings from harmfulcurrents. These currents damage themotor winding through overtemperature.The conditions are often caused by over-loading the motor, sustained low voltage,or stalled rotor.
Melting Alloy overloads include a tripindicator and manual test feature. Anisolated NO or NC contact is available.
Size 0-1%Bimetal Starter
Bimetal starters, together with theproper heater elements, help to provideprotection to motor windings fromharmful currents. These currents dam-age the motor winding throughovertemperature. The conditions areoften caused by overloading the motor,sustained low voltage, or stalled rotor.
Bimetal overloads are convertible frommanual to automatic reset. Heaters canbe selected as standard class 20 orquick trip class 10. Starters can be fac-tory ordered with a NO/NC (SPOT)Form C contact.
30
6°
•q
Siemens & Furnas Control Products
m%> Magnetic Motor ControlsNEMA Catalog Numbering System
General
Class
17 —
18 —
25 -
26 —
Combination Starter(Non Fusible, Fusible)Combination Starter(Circuit Breaker)ReversingCombination Starter(Non Fusible, Fusible)ReversingCombination Starter(Circuit Breaker)
£f5s
Size
Q
DE —F -G -HI —J —K —L —M —N —p
0117. & IP22V:33V'44/556
Modelp
ST -R —
Innova Plussize 0-4ESP100ESP100ESP100size 0-5
Enclosure Size
92 — Standar82 —72
ESP 100Current Range5'
Three
A —B —CD —c _
F —us G —
H —ize 0-37 jize 4-8 K>elf-Reset |_
M —S —
Phase
!<4-1y.i-33-6214-109-18
13-2720-4022-4530-6045-9057-11567-135100-210
Extra WideHorizontalCompact
Enclosure Type -
Breaker HP Code®Horsepower Rating200, 230, 460, 575
B —FN —N —W —
NEMA 1NEMA 4XNEMA 12Convertible to 3/3RNEMA 4/4X Stainless
A —BC —D —E —F —G —H —J —K —LM —N —PR —S —T —V -W —X —
14, »,1,11, 1, 3, 33, 5, 5, 53, 3, T/,', I'/.
T/i, 7/!>, 10, 105, 5, 15, 1510, 10, —,—7V, 10, 20, 2010, 15, 25, 2510, 15, 30, 3015, 20, —, ——, —, 30, 3025, 30, 50, 5030, 40, 75, 7540, 50, 100, 10050, 75, 150, 15050, 75, 150, 20075, 100, 200,—100, 125,250,300150, 200, 400, 400
Class
14 -
22
40 —
43 —
Size -
BCDEFGHIJKLMNP
Across the Line NEMAMotor StarterReversing NEStarterAcross the Line NEMAMagnetic ContactorReversing fContactor
0001TA&22/7
33'/!
44/i5
Model
I
\IEMA
Motor
MEMAtorMagnetic
ESP 100Current Range '
Three Phase
Pilot Control Circuit
1PG —
S —T —R
Innova Plussize 0-3/'Compact size 00Innova Plus size 4ESP100 sizeO-3V:ESP100 size 4-8ESP100 Self-Resetsize 0-5
Power Poles
1 — 2 power poles.1 phase3 — 3 power poles, 3 phase
Additional Options1 Phase Reversing(Class 22 & 43 only)5 —
8 —
4 power poles4 wire split phase allleads broken3 power poles
ABCDEFGHJKL.MSUXYz •
'/4-1
Xi-3
3-62'/i-109-1813-2720-4022-4530-6045-9057-11567-135100-210100-270200-540420-820420-1220
.ffl
2 — suitable for3 wire control(NO aux.
contact incl.)5 — 2 wire control
(NO aux.
contact notincl.)
Coil
F —
G —
J®_
Enclosure Type
Single Phase'1
ABDFHOW
OpenNEMA 1NEMA 3 (sizes 0-170NEMA 4XNEMA 7 &9, boltedNEMA 12 Convertible to 3/3RNEMA 4/4X Stainless Steel
110-120V/220-240V@60Hz110V/190-220V@50Hz220-2 40V/440-480V@60Hz190-220V/380-440V@50Hz200-208V@60Hz550-600V@60Hz550V@50Hz120V@60Hz110V@50Hz220-240V@60Hz190-220V@50Hz440-480V@60Hz380-440V@50Hz24V@60Hz24V@50Hz277V@60Hz240V@50Hz
— /
— 84 wire split repulsioninduction
9 — 3 power poles4 wire split phase one
Class
36 -
37 -
Non ComboReducedVoltageStarterComboReducedVoltageStarter
Size
CD£
F —G —H —1JK —L —M^N —P —
011%22V2
33'/2
44'/i5678
Model
ESP 100 Cur
ine direct
A '/^l
B — "A— 3D — 2/-10E j- ipo- Ib
i
ent Range Type
S — ESP100 T —size 0-4 P —
T — ESP100 O —size 4'/2-8
C
Line Volts Enclosure Type Coil Disconnect Type1'"
Auto XFMR 2 — 230 A — Open D — Non Fused Disc.Part Wind. 3 — 380 B — NEMA 1 F — Fusible Disc.Wye Delta 4 — 460 W — NEMA 4/4X P — MCPOpen Trans. 5 — 575 Stainless Steel T — Thermal MagneticWye Delta 6 — 200/208 O — NEMA 12Closed Trans.
CDSingle phase ESP100 available on Class 14 Startersonly.
'DNot used on Class 17, 25 or with ESP100 versions.@Not available on sizes 41/2-8.
®For Class 37 only.©Position used for ESP100 only.
52Siemens & Furnas Control Products
Heavy Duty Controls ModificationsFactory Modifications
Selection
Ordering Instructions
> Catalog Number Suff ixes indicate num-
bers or letters added to the end of a
catalog number. Example: 14DP32BA
becomes 14DP32BAA1.
> Multiple Modification Suffixes are added
in numerical, alphabetical sequence.
Overload Options
Overload Relay Classes 14, 17, 18, 22, 25, 26, 36, 37
Description
AmbientCompensatedBimetalBimetal Overload Locked in Position'1
Variable Trip Locked in 100% PositionReset Locked in Manual PositionVariable Trip and Reset Locked
ESP100 Trip Class Option
Description
ESP1 00 Single Phase
TripClass
Class 10 or 20(K or E heatersl
Class 10Class 30
Phase
1 Phase
Phase
3 Phase
1 Phase
3 Phase
Contacts
NCNO & NC. SPOTNC
NCNC
Available OverloadAmp Ranges
0.25-1.00.75-3.02.5-105-1 6
Catalog NoSuffix
81918
SIS2S
5153
Controller Size — Price Addition $00 -I3/.
NC36.NC
2, r/zNC36.NC
3, 3'h
NC
—
4
NC
Add S3 to PriceAdd S3 to PriceAdd $6 to PriceNCNC
LetterDesignation (5th Char)
A
B
D
E
NCNC
Catalog NoSuffix
X359U
NCNC
NCNC
Controller Size — Price Addition $00-1
NC
Overload Relay Classes 30, 32, 83, 84
Description
AmbientCompensatedBimetaBimetal Overload Locked in Position®Variable Trip Locked in 100% PositionReset Locked in Manual PositionVariable Trip and Reset LockedMelting Alloy
TripClass
Class 10 or 20
Class 84
Phase
3 Phase
1 Phase
1 Phase
Contacts
NCNO & NC, SPOTNC
NC
Catalog NoSuffix
81918
SIS2SX359U
Controller Size — Price Addition $00-1'/4
NC72.NC
2, 2'A
NC72.NC
3, 3'/2
NC
4
NC
Add S3 to PriceAdd S3 to PriceAdd $6 to PriceNC NC | NC -
*
Overload Options for NEMA Size 00 (14 BG. 22 BG)
Overload Relay
Description
AmbientCompensatedBimetal
Phase
1 Phase NC3 Phase NCN C & N O ( S P D T )
Catalog NoSuffix
88191
Class
—
PriceAddition $
NCNC30.
NEMA 4X Fiberglass Enclosure Options®
Description
Non-Combination
Catalog NoChange
7th Char to F, 8th Char for ESP100
Class
14 ,22 ,40 .43
Controller Size — Price Addition $
00-1%
228.
2, fh
492.
3, 3%
780.
4
1065.
Description
Non-Combination
Combination Circuit Breaker
Combination Fused Disconnect Switch
Combination Non-Fused Disconnect Switch
Catalog NoChange
7th Char top 9th Char for ESP1 00
7th Char t o p 9th Char for ESP100
7th Char to F, 9th Char for ESP1 00
7th Char to F, 9th Char for ESP1 00
Class
30
32
32
32
Controller Size — Price Addition $
0
188.
225.
378.
339.
1-1%
192.
242.
387.
350.
2, 2V,
210.
252.
560.
490.
3, 3%
375.
777.
854.
756.
4
869.
1534.
1641.
1454.
©Minimum order and release, 50 units.®Price addition to open style pricing.
Discount Schedule AC-10 (FURN)
Siemens & Furnas Control Products
^pHeavy Duty Controls ModificationsFactory Modifications
Sele
Ordering Instructions
* Catalog Number Suffixes indicate numbers or letters added to the end of a catalog number.
Example: 14DP32BA becomes 14DP32BAA1.
> Multiple Modification Suffixes are added in numerical, alphabetical sequence.
Coil Options
Control Options
Description
AC Coil"1
Volts 60HZ
24 Separate Control120 Separate Control110-120/220-240200-208220-240277220-240/440-480440-480550-600
DC Coil
Volts MHZ
24110110/190-220
190-220240190-220/380-440380-440550
DC Coil and AC-DC Rectifier
LabelColor
BlackBlackBlueOrangeBlueOrangeRedRedOrange
12V24V32V48V125V
250V
120V AC240V AC
Catalog NoChange
8th char
9th char esw>,r
9th char
9th char espvo "
10th char
12th char esffj '>"
11th char12th char esfW"13th charesfiK"Coil Letter
JFADGLCHE
RSTUVwVYWY
Class
11.17,22,25,36, 37, 40, 43
18,26
30
3232 Breaker32 Disconnect
All
All
AllInnova
EnclosureType
All
All
All
Controller Size — Price Addition $
0-1%
NC
102.
228.
294.
2. 2%
NC
102.
228.
294.
3. 3%
NC
198.
240.
306.
4
NC
264.
240.
390.
4%, 5 6 7 8
Dual voltage coilsnot available
NC
330.
456.
522.
NC
—
NC
—
NC
—
Description
Surge Suppression for 120V AC Coil
Disconnect Switch Interlock 2 NO/2 NC DPDT
Motor Circuit Mn/Mp c-nrvrProtector Interlock NO/NC SPDT
Circuit Breaker Shunt Trip
Circuit Breaker Undervoltage Trip
Circuit Breaker Alarm Switch Trip
1 Phase Combination Starter
Isolated Alarm Contact on Melting Alloy Overload
Ground Lug - 1 Conductor
Blown Fuse Indicator Lights
Control Circuit Fuse and Holder 1 Fuse(Transformer Primary Fusing) 2 Fuses
Control Circuit Fused DisconnectInternally Operated
Control Circuit Circuit BreakerInternally Operated
Convenience Receptacle Mounted onSide of Enclosure
Drip Hood
Space Heater
Space Heater with Thermostat
Catalog NoSuffix
SS
GY
GY
L6
L7
L8
X359U
L9
L10
L11
F1
F2
F3
F4
RE
DP
SH
ST
Class
17,25,32,36,37,87
18,26,32,36, 37, 87
All
All
All
17, 18
All
All
All
All
All
All
All
All
EnclosureType
All
1 , 3 , 4 , 1 2
1,3,4,12
All
All
All
All
All
All
All
1,3,4, 12
1 ,3 ,4 ,12
1,3 ,4 ,12
1,12
1
1,3,4, 12
1,3,4, 12
Controller Size — Price Addition $
0-1 %
54.
88.
174.
495.
495.
495.
NC
75.
12.
300.
132.
132.
324.
522.
120.
108.
420.
450.
2, 2Vi
54.
88.
174.
495.
495.
495.
NC
75.
12.
300.
132.
132.
324.
522.
120.
132.
420.
450.
3, 3'/2
54.
88.
174.
495.
495.
495.
NC
75.
12.
300.
132.
132.
324.
522.
120.
396.
420.
450.
4
88.
174.
495.
495.
495.
—
75.
12.
300.
132.
132.
324.
522.
120.
396.
420.
450.
4'/z. 5
66.
174.
174.
495.
495.
495.
—
75.
12.
300.
132.
132.
324.
522.
120.
528.
420.
450.
6
66.
174.
174.
495.
495.
495.
—
75.
12.
300.
—
324.
522.
120
720.
420.
450.
7
66.
174.
174.
495.
495.
495.
—
75.
12.
300.
324.
522
120.
720.
420.
450.
8
66.
174.
174.
495.
495.
495.
—
75.
12.
300.
—
324.
522
120.
720.
420.
450.
Description
Reversing in one speed only 2 speed 1 windingReversing in one speed only 2 speed 2 windingReversing in both speeds 2 speed 1 windingReversing in both speeds 2 speed 2 winding
Catalog NoSuffix
X439UX440UX441UX442U
©Voltages and frequencies not listed, contact salesoffice.
ProductClass
30,32
Controller Size — Price Addition
0
720.
696.
972.
1080.
1
774.
748.
1056.1164.
I3/.
877.
894.
1418.1654.
2
1032.1052.1668.1946.
$
2%
1275.1316.2111.2377.
3
1500.1548.2484.2796.
3'A
1721.1776.3274.3244.
4 5
2025.2090.3852.3816.
Discount Schedule AC-10 (FURN)
Siemens & Furnas Control Products
Heavy Duty Contactors and StartersAuxiliary Contact Configurations
Technical
Heavy Duty Non-Reversing Contactor And Starter AuxiliaryContact Configurations
Heavy Duty Reversing Contactor And AuxiliaryContact Configurations
Size
0-1 3/«
2-4V/i. 5
6,7
8
Standard Contactsat No Additional Price
1-NO
1-NO2-NO and 2-NC
1-NO and 1-NC
1-NO
Extra Contacts in AdditionTo Standard Contactsfor an Additional Price®®
Left Hand Side
2-NO or NC
1-NO or NC1-NO and 1-NC
1-NO and 1-NC
Right Hand Side
2-NO or NC
2-NO or NC1-NO and 1-NC
2-NO and 2-NC
4-NO and 4-NC
Size
0-1 !/i (Left Cont.)0-1 3/< (Right Cont.l2-44'/z, 5 (Left Cont.)4'A 5 (Right Cont.)6, 7 (Left Cont.)6, 7 (Right Cont.)8
Standard Contacts®Per Contactorat No Additional Price
1-NO and 1-NC1-NO and 1-NC1-NO and 1-NC2-NO and 2-NC2-NO and 2-NC1-NO and 1-NC1-NO and 1-NC2-NO and 1-NC
Extra Contacts Per Contactorin Addition to Standard Contactsfor an Additional Price®®
Left Hand Side
2-NO or NC1-NO or NC1-NO or NC1-NO and 1-NC
1-NO and 1-NC2-NO and 2-NC
Right Hand Side
1-NO or NC2-NO or NC1-NO or NC
1-NO and 1-NC2-NO and 2-NC1-NO and 1-NC3-NO and 3-NC
"0!
Non-Reversing
Size 0-1 /:
1
I
I
I
f i l lniliiii
Size 2-4
II1I
I I II I !
1I1I
Size 4/, 5
Reversing'*, Two Speed Two Winding*
Size 0-VK
u -*r-1
I
I
I l l l
I I I I
1
I
I
I
Size 2-4
IIiI
111III
\1I
-X- 111
Size HV,, 5
Size 6-7
Size 8
X
®lf extra auxiliary contacts are required in addition tothe maximum available, add a control relay to theenclosed starter from the factory modifications.
©See page 117 or 122 for price on additional auxiliarycontacts. Extra contacts shown above are shaded.
©For each contactor, 1-NC contact used for standardelectrical interlocking scheme and 1-NO for seal incontact.
®Two Speed One Winding Controls require extra powerpoles or third contactor. Configurations will vary.
Siemens & Furnas Control Products
«%> Heavy Duty Contactors and StartersControl Ratings
Technical
NEMA Electrical/Mechanical Ratings
Size
2
2'/>
3
3'X
4
4!/'
5
6
7
8
LoadVolts
115200230380460575115200230380460575115200230380460575115200230380460575200230380460575200230380460575200230380460575200230380460575200230380460575200230380460575
Max HP
Plugging &Normal Duty Jogging Duty
1 Ph
3—r/2
-5
—10
—
7'/2
—
15
—
—
——
——
—
————
————
-——
——
—
-——
——
3Ph
1015252525_1520303030—
2530505050
3060607575405075
100100
5075
10015015075
100150200200150200300400400—
300—
600600—
450—
900900
1 Ph
2—5
——
—
—
——
——
——
————
—
——
—
—
————
————
————
3Ph
—B410151515
1015202020—
1520303030—
20253040402530506060304075
100100
6075
125150150125150250300300————
—
—
—
ContAmps
454545454545606060606060909090909090
115115115115115115135135135135135210210210210210270270270270270540540540540540810810810810810
1215
1215
1215
1215
1215
ServiceLimitAmps
525252525252656565B56565
104104104104104104125125125125125125156156156156156225225225225225311311311311311621621621621621932932932932932
1398
1398
1398
1398
1398
Tungsten &BallastTypeLamp Amps480 VoltsMax
6060606060
7575757575
100100100100100
150150150150150
200200200200
—————————
————
————
————
—
ResistanceHeating kW
1 Ph
8.11416.1—32.2
40.3
10.4
1820.7—41.4
51.8
14.4
2528.8—57.5
71.9
18.4
32368—73,6
923944.9—897
11253609
122152
7080.5—
161201—
120—
240300
180—
360450———
—
3Ph
13924.2
27846.0
55.7
69.6
17931.1
35859.2
71.6
89.5
24.8
43350.0
82.2
99.4
12431.8
55.4
637105127159
67.5
776128155194
91.7
105174211264121139230278348162210342415515—
315—
625775———
—
Transformer Switching 50-60HzKVA Rating Inrush Peak TimeContinuous Amps
20 Times 20-40 Times
1 Ph
2 1—
4.1—
8.310.0
3.1—
6.1—12154.1
—8.1
—1620——11—21.5
37—14—2734—20.5—40.5
51—27—5468—54—
108135——-—
————
—
3Ph
—6.37.2
—1418—
9.110.6
2126.5
—1214—2835—1618.5—37.5
472023—475930.5
35—
70.5
884147—94
1178194—
188234—————————
—
T Ph
1 0—
2.1—
4.25.21.5
—3 1
—6.1762.0
—4.1
—8.1
10——
5.4—11.0
13.5
—6.8
—1417—10.4—20.5
25.5
—14—2734—27—5468
———
————
—
3Ph
—3.13.6
—7.28.9
—4.65.3
—106134
617.0
—1418—
89.5
18.5
23.5
1012—23291518—35442024—47594147—94
117————
————
—
CapacitorKVASwitchingRating3PhKVAR
—8
—1620——17.5
—34543.5
——27—5367—
33.5—66583.5
40—80
100—60—
120150—80—160200—
160—
320400—
240—
480600—
360—
720900
MechanicalLife
10 millionoperations
10 millionoperations
5 millionoperations
5 millionoperations
5 millionoperations
1 0 millionoperations
10 millionoperations
5 millionoperations
5 millionoperations
5 millionoperations
Max HP 380V 50Hz Ratings
33Q)
£?>
Class
14,40
30,32
36,37
Description
Var & Const TorqConst HP
Auto TrWye Delta
Control Size 3 Phase
0
553
—
1
10107/
1015
1%
1515101525
2
2525202540
2%
3030253050
3
5050405075
3!460605060
100
4
75756075
150
4%
100100
75100200
5
150150100150250
6
300300200300500
7
500500300500800
8
700700400700
1000
Siemens & Furnas Control Products