12 SOUTHLAND RD. ORMOND BEACH, FL 32174TELEPHONE 904-677-9110 FAX 904-673-5497
Product Catalog
Alpha-Numeric Index
Pictorial Index
aworld classorganizationservingthe needsof the globalelectric utilityindustry
Since 1963, HOMAC has become a leader in the utilityindustry as a connector supplier. We haveaccomplished this with:
Innovative EngineeringHOMAC and Innovation go hand in hand when it comesto electrical connectors. By working closely with you, thecustomer, we have been able to provide solutions tomany applications making life much easier for installersand saving them time and you money. Many of these“special” applications have grown to become industrystandards today.
Top QualityOur facilities are ISO 9001-2000 Certified. Our goal is togive you the very highest quality product in the industry.
On Time DeliveryWe know you schedule your work around receivingmaterials for the job. Our delivery goal is to get you theright material in a timely manner and more importantlyas promised. We’re investing to reduce lead time.
Competitive PricesNothing else matters if we can not be price competitivein today’s market. Our goal is to supply you with thelowest installed cost connectors. By designing time-saving connectors, you can save money in labor and getyour customers in service much faster, generatingrevenues.
MissionTo be a premier manufacturer and supplier of Electric PowerDelivery Connectors and cable accessories; we are committed toWorld-Class performance as demonstrated by continuousimprovement in safety, innovation, quality, cost, flexibility,and customer satisfaction.
AA
800 Series.....................1002042 Series...................... 82043 Series...................... 82100 Series...................1022100 Series (Boots)........ 222131 Series.....................742723..............................1032726..............................1032729..............................1033135................................443133................................445575..............................1046318................................4416000 Series.................10139000............................100
A A....................................111AAC-FT...........................80AASL-N...........................79ABC................................ 23ABK Series, ABCK, ABKW,AK..............................10-11ABN................................ 20ABP.................................84ABS.................................19ABT.................................12ABW............................... 18AC.................................. 64AC-R...............................68ACSR-FT....................... 81AD................................ 112A-L & AD-L................... 114AL-N............................... 54AL4-N............................. 61
AL-LTN........................... 77AL-RTN...........................77AL-TN............................. 53AL-NTN.......................... 52ANA.............................. 114ANLT & ANLTT.............. 75APH................................ 25AQ.................................114ASC-TN.......................... 64ASG..............................112ASC-TN.......................... 64ASL-N........................54-55ASL-NTN........................ 52AT3A, 4A...................... 113AT & ATT....................... 72ATC.................................65ATC-R.............................66AVH................................ 2AX.................................114
B BB...................................22BBV.................................21BMS................................78BOLTAP(4000-5000) 90-91BS.................................101BY.................................. 50
C C.....................................70C-5000............................44CAP...........................43-44CB................................ 115CBB3344........................ 15
CC................................ 106CD................................ 116CD40B............................93CEA.................................. 9CFA.................................55CFB................................ 29CFG................................29CFK.................................29CIC..................................44CL...................................38CLR.................................25CN600B..........................93CNC................................44CO (MECH).................. 115CO20B............................93CP.................................117CS (MECH)...................116CS (outlet cover).............. 1CSB................................ 24CSN..................................1CSS................................ 16CST................................ 42CSW............................... 16CVC................................44CX.................................116
D DB.................................. 93DB-ST.............................94DC................................ 115DC402............................ 94DF & DH........................... 6DKB.................................. 7DKB-N.............................. 7DKB1................................ 7DKB1-N............................ 7DKBU............................... 7DS.................................101DSKB............................... 7DSKB-1 & 1N................... 7DSKB-N........................... 7DSKBU............................ 7DST................................ 94DYA, DYC, DYU-M.........48
E E................................... 105E-GP.............................105EZ...................................13
F FB...................................21FB-NR...........................108FBV................................ 21FB4N-B...........................21FS-48..............................27FSH................................ 25FSK.................................41FS95...............................29FS125........................27-28
FSN-125......................... 27FS175.............................26FS1175...................3, 4, 26FSS & FSS-L..................38FSS (3 & 4 Wire twin tapcovers)............................39FST, FST-N.................... 28FSTT, FSTT-N................28FSX, FSX-N....................28FSXX, FSXX-N...............28FSY, FSY-N....................28FTH.................................. 4FTN-125........................... 2FTN-175........................... 3FT95................................. 5FTT...................................4FTU-95............................. 5FTU-125............................1FTU1 & 1N........................1FYA, FYC, FYU & -M......48
G GB-8000................109-110GHD, GHN, GHO........... 42GG................................104GS.................................101GSS................................92
H H1.................................100H7.................................120HD.................................. 42HDL-N.............................59HL..............................62-63HL-N............................... 63HLB.................................94HL-CS.............................29HLCB..............................94HLSCB............................94HM53 & HM56..............126HN.................................. 42HO.................................. 42HOB................................93
J J1C............................... 100J2C............................... 103
K KB.....................................7KB1...................................7KB1-N...............................7KBU.................................. 7
L L1................................. 100L1C...............................100L................................ 60-61L-N..................................58L-4N................................61
Quick Section Index: Page
1-2021-2223-3536-4243-4647-5152-6364-7172-7576-7879-8182-8788-95
96-103104-110111-118119-125126-127
C-E
Pad Mount Transformer ConnectorsInsulating BootsPedestal & Handhole ConnectorsUnderground Splicing"Flood-Seal" ProductsStreetlighting KitsAL / CU Compression Lugs - TerminalsAL / CU Compression SplicesAL / CU Compression Tee ConnectorsMeter Socket LugsMulti-Range Taking ConnectorsOverhead Transformer ConnectorsOverhead Taps & StirrupsOverhead SplicingGrounding SectionAL / CU Mechanical ConnectorsTools & Dies MiscellaneousPictorial Index
Alpha Numeric Index*
B
L2................................. 102L2C...............................103L2E............................... 103LRT.................................17LRT (Magiconn)..............15LRTR...............................17LRTRW...........................17LRT-U.............................15LRT-UW..........................15LRT-UX...........................15
M ML................................ 118MS................................ 101MTB................................40
N N1R.............................. 100NB...................................93NB-ST.............................94NBL.............................. 117NC.................................. 94NLT & NLTT................... 75NST................................ 94
O OB.................................. 93OC.................................. 94OL...................................94OST................................ 94P PB...................................22PC...................................71PS...................................44PSX................................ 44PT(Power Taps/shells)... 89PTA.................................79PTC.................................71PTB, PTL, PTM.............. 83PTSB.............................. 86PTSG..............................86PTSK.............................. 86PTSL...............................86
Q Q1.................................100Q2.................................102Q2C.............................. 103Q5U................................ 83QH.................................. 95QS................................ 101
R RAB................................ 34
RAU................................16RG5U............................. 82RRK...........................36-37RS.................................101RSB................................ 87RSG................................87RSK................................ 87RU5U..............................82RX5U..............................82RXL.................................34RXM................................35
S S1................................. 100S..................................... 94S2C.............................. 103SA...................................55SA-N...............................54SA-NTN.......................... 52SAB-N.................... 54 & 56SAC................................ 67SAC-R............................ 67SAF-N.............................56SAF-4N...........................57SAKM............................. 76SAK-N.............................56SAL-N.............................56SAL-4N...........................57SAM-N............................56SAM-4N..........................57SASL-48......................... 55SASL-N.......................... 54SATC..............................65SB (Boots)...................... 22SC...................................70SDK-M & -A....................47SDT-M & -A.................... 47SG.................................. 69SGAC............................. 80SH.................................. 95SHC...........................30-31SHC4/0...........................31SHC Double 4/0..............31SHC500-Dbl.4/0's...........31SKAC..............................81SKB.................................. 7SKB1................................ 7SKB1-N............................ 7SKBU................................7SL3................................. 50SL-N............................... 58SLK-M & -A.................... 47SLT-M & -A.....................47SNC................................45
SNG................................99SQG..............................127
T T..................................... 73TC...................................71TBC & TBC-GP............ 107TNC................................ 46
TOOLS & DIES............ 119EP-630 & 750............... 124REC-630 & 750............ 123SPC 21851................... 122SPC 21852................... 122UT3 & UT3-M............... 119UT4C & UT6C andReplacement Parts.......125UT5...............................120UT15 & UT15N.............12115599........................... 12215596........................... 121H Series Dies............... 12015 CAP......................... 12215 CA Series................ 12215 CA-R Series............ 12215 C-R Series...............12215 CZ............................122
TPH................................ 85TSC.................................. 9TT................................... 73
U U1.................................100U1B................................ 96U1N................................ 96U2.................................102U2A9.................... 80 & 102U2C.............................. 103U5U................................ 83UGG............................... 96UB214.............................93UF...................................51HG.................................. 96UH11.............................. 40UH (500-10000).........32-33UH750 with 4/0’s............ 33UH750 with 350’s........... 33UH-R (750-1000).......32-33ULCK..............................41ULSK.............................. 41UO.................................. 96UR.................................. 96USK................................ 40
USK Repair Splice..........40UY...................................96
V Multi-Range TakingLugs/ Stacking Lugs& Pin Terminals............. 79
W W2................................ 102WH................................. 95WL................................ 127WLP..............................127WS................................101
X X1N................................ 97X1U................................ 98X5U................................ 83
Y Y1................................. 100YFA, YFC, YDA, YDC,YFU, YDU.......................49
Z Z..................................... 13Z1................................. 100Z2................................. 102Z2C...............................103ZB...................................93ZBC................................ 14ZBT.................................12ZVB................................ 14ZVW............................... 14
12 Southland Road, Ormond Beach, FL 32174 • Phone: 386-677-9110 • Fax: 386.673.5497 • E-mail: [email protected] • www.homac.com
C
Underground Distribution Pictorial Index
FTU SeriesPage 1
ABT & ZBT SeriesPage 12
ZEEBARS Page 13
ABC Series PedestalConnectors Page 23
FS1175 Insulating SleevePages 3, 4 and 26
ZVW & ZVB SeriesPage 14
Magiconn SeriesPage 15
RAU SeriesPage 16
CLR Series PedestalConnectors Page 24
CSW & CSS SeriesPage 16
LRT SeriesPage 17
FS95 Series & KitsPage 29
RXM SeriesPage 35
RRK Series Splice KitsPages 36-37
"Flood-Seal" SubmersibleSplice Covers Page 38
"Flood-Seal" 3 & 4 Wire TapCovers Page 39
Repair Splice Kits andMechanical Splice & Tap Kits
Page 40
RAB Series and RXL Series ConnectorsPage 34
All SHC Series Sweetheart Connectors Pages 30-31
All UH Series ConnectorsPages 32-33
HUB SystemPage 25
FS175 SeriesPage 26
FS-125 & FSN-125 SeriesPage 27
FS 1 & 2 Hole Series and FS 'Y', 'T' & 'X' SeriesPage 28
FB Series EPDM Rubber BootsPage 21
PB, BB & SB Series BootsPage 22
ABW, ABS & ABN SeriesPages 18-20
LRTR-W &LRTR
Page 17
FTN125 SeriesPage 2
FTN175 SeriesPage 3
FTT & FTH SeriesPage 4
DF & DH SeriesPage 6
CEA & TSC4Page 9
All ABK SeriesPages 10-11
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
12 SOUTHLAND RD. ORMOND BEACH, FL 32174TELEPHONE 904-677-9110 FAX 904-673-5497
D
CompressionConnectors
OverheadTransformerConnectors
Pictorial Index
ULCK-ULSK & FSKSplice Kits Page 41
AL-N Series StackingLugs Page 52
Aluminum 4 HoleLugs Page 57
CU 2 Hole StackingLugs Page 58
CU Heavy Duty Lugs Page 59
CU 1 Hole LugsPages 60-61
AL or CU 4 HoleLugs Page 61
CU Peep HoleLugs Pages 62-63
ASC & AC Series Aluminum SplicesPage 64
AL TaperedSplices Pgs. 65-66
AL Tapered TeesPage 72
Meter Socket LugsPage 77
Bi-Metallic PinTerminals Page 78
"Flood-Seal" Insulated PinTerminals Page 82
Compression PinTerminals Page 83
ABP Series withCopper Stud Page 84
Transformer BushingPads Page 85
ABP with BoltedOutlets Page 84
Multi-Range Taking ConnectorsPages 79-81
AL Low VoltageTees Page 72
CU Tapered TeesPage 73
CU CompressionTees Page 73
CU Clamp TeesPage 74
NEMA Lug TeeTaps Page 75
Meter Socket Lugs'840' size Page 76
AL Common DieSplices Pg. 67
AL to CUReducers Page 68
Tinned AL SplicesSG series Page 69
CU Straight Oil StopSplices Page 71
Tinned CU SplicesPage 69
CU Tapered &Tapered Oil StopSplices Page 71
AL Series 1 HoleLugs Page 53
SA-N Common DieStacking Lugs Page 54
SA Series 1 HoleStacking Lugs Pg. 55
Aluminum 2 Hole LugsPage 56
Cable End Caps & PipeSealers Pages 43-44
Streetlighting KitsPages 47-50
UF Cable Splicing KitsPage 51
Twin Tap Kits and Twin Tower Outlet SleevesPage 42
E
OverheadTransformerConnectorsContinued
Pictorial Index
Shrouded Lugs and Pin TerminalsPages 86-87
All Wedge and Tap ConnectorsPages 88-93
All Hot Line Stirrupsand Bails Pages 94-95
5/8" Service EntranceSplices Page 96
Service Entrance Splices'840' Size Pages 97-98
CU Screw Lugs withOffset Tangs Page 115
Utlilty CableSlicers
Page 125
UT3 & UT3MHand HeldInstalling
ToolsPage 119
WildlifeProtectorsPage 127
JointCompoundsPage 126
UT5Compression
Tooland DiesPage 120
UT15HydraulicTool, Dies
andAccessoriesPages 121-
122
DielessCrimping
Tools - Handor BatteryOperated
Pages 123-124
CU Screw Lugs w/StraightTang Page 116
'CP' Series Screw Lugs & CU Neutral Bars Page 117
'ML' Series CopperMechanical Lugs Page 118
All Tension and LoopSplicers Pages 99-103
AL Screw Lugs, MultipleBarrel Types Page 113
Panelboard Lugs, Neutral BarAssemblies and Locking Lugs Page 114
'C' Taps, Flexible Braid Jumpers, Split Bolts, Pole ButtPlates - to mention just a few. Pages 104-110
Grounding Section
AL / CUMechanicalConnectors
Tools& Dies
Miscellaneous
'A' Series Single BarrelScrew Lugs Page 111
'AD' & 'ASG' Series, Two Barreland Switchgear Types Page 112
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
aworld classorganizationservingthe needsof the globalelectric utilityindustry
Since 1963, HOMAC has become a leader in the utilityindustry as a connector supplier. We have accomplishedthis with:
Innovative EngineeringHOMAC and Innovation go hand in hand when it comesto electrical connectors. By working closely with you, thecustomer, we have been able to provide solutions to manyapplications making life much easier for installers andsaving them time and you money. Many of these “special”applications have grown to become industry standardstoday.
Top QualityOur Ormond Beach, Florida facility is ISO 9001 Certifiedand we are on our way with certification of our otherlocation. Our goal is to give you the very highest qualityproduct in the industry.
On Time DeliveryWe know you schedule your work around receivingmaterials for the job. Our delivery goal is to get you theright material in a timely manner and more importantly aspromised. We’re investing to reduce lead time.
Competitive PricesNothing else matters if we can not be price competitive intoday’s market. Our goal is to supply you with the lowestinstalled cost connectors. By designing time savingconnectors, you can save money in labor and get yourcustomers in service much faster, generating revenues.
• Speed of Response Exceeding Customers’Expectations
• Consistently Exceeding Customers’ Expectations for Quality
“Be a supplier of choice for our customers” By ...
• Flawless Customer Service
• Continuous Improvement in Engineering Service and Innovation on Behalf of Customers
MISSION STATEMENT
The Homac Companies
Pad
Mo
un
tTran
sform
er Co
nn
ectors
Flood-Seal”® Disconnectable125 Series Secondary TransformerConnectors with 1 or 2 Hole Outlets
• REA APPROVED, Dead Front Construction.
• Internal/external threaded bushing adapter for removalof connector without disassembling individual cables.
• Off-set handle design positions cable weight close to tank wall.
• Heavy PVC insulated aluminum body.
• Outlets equipped with 1/2" hex head bolts with captive bellevillewasher - accepts standard side formed 1-hole and 2-hole NEMA lugs.
• Cable range from #8 thru 500 MCM alumnum or copper.
• Outlets sealed with range taking rocket cap/sleeve, orderedseparately. Suffix “AWR” to order assembled with rockets.
• “Flood-Seal” connectors comply with ANSI specification C119.4.
“
NOTE: ROCKET SLEEVES NOT INCLUDED. USE SUFFIX “AWR” TO RECEIVE ASSEMBLED WITH ROCKETS. ORDER LUGS SEPARATELY.
CATALOGNUMBER
FTU125-2
FTU125-3
FTU125-4
FTU125-5
FTU125-6
FTU125-44
FTU1-125-2
FTU1-125-3
FTU1-125-4
FTU1-125-5
FTU1-125-6
FTU1-125-44
CATALOGNUMBER
FTU-2N
FTU-3N
FTU-4N
FTU-5N
FTU-6N
FTU-44N
FTU1-2N
FTU1-3N
FTU1-4N
FTU1-5N
FTU1-6N
FTU1-44N
FIG.NO.
1
1
2
2
2
2
1
1
2
2
2
2
FIG.NO.
3
3
4
4
4
4
3
3
4
4
4
4
NO. OFOUTLETS
2
3
4
5
6
8
2
3
4
5
6
8
STUDSIZE
5/8
5/8
5/8
5/8
5/8
5/8
1
1
1
1
1
1
* L4-7/8
6-5/8
7-1/8
9
10-3/4
7-1/8
4-7/8
6-5/8
7-1/8
9
10-3/4
7-1/8
C
3-7/8
3-7/8
5-3/16
5-3/16
5-3/16
5-3/16
3-7/8
3-7/8
5-3/16
5-3/16
5-3/16
5-3/16
C
5-5/8
5-7/8
6-15/16
6-15/16
6-15/16
6-15/16
5-5/8
5-5/8
6-15/16
6-15/16
6-15/16
6-15/16
* L dimension is the same for 1 hole or 2 hole version.
FORCE FIT ROCKET SLEEVES MATERIAL: EPDM RUBBERRECOMMENDED 1 HOLE OR 2 HOLE
AL-CU COMPRESSION LUGSWIRESIZE
#8 STR#6 STR#4 STR#2 STR1/0 STR2/0 STR3/0 STR4/0 STR
250 MCM300 MCM350 MCM400 MCM500 MCM
2 HOLECAT.NO.
SA8-NSA6-NSA4-NSA2-N
SA1/0-NSA2/0-NSA3/0-NSA4/0-NSA250-NSA300-NSA350-NSA400-NSA500-N
1 HOLECAT.NO.SA8-48SA6-48SA4-48SA2-48
SA1/0-48SA2/0-48SA3/0-48SA4/0-48SA250-48SA300-48SA350-48SA400-48
CFA500-48
FOR 1 HOLE OUTLETCONNECTORS
FOR 2 HOLEOUTLET
CONNECTORS
1
EPDM RUBBERBUSHING STUDCOVER SUPPLIEDWITH CONNECTOR
PATENTED
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
Flood-Seal”® 125 Series NEMA SpadeConnector with 1 Hole or 2 Hole Outlets• For dead fronting pad mount transformers with 4-hole NEMA
spade secondary bushings.
• Outlets accept standard side formed AL-CU lugs.
• Rocket shaped EPDM sleeves are available to fully insulate the secondary side.
• All outlets are provided with 1/2" plated steel hex head bolts andcaptive belleville washer.
• Cable range from #8 to 500 MCM aluminum or copper.
• All “Flood-Seal” connectors comply with ANSI C119.4 requirements.
• Maximum contact assures cooler operating, more reliable joints.
FORCE FIT ROCKET SLEEVES MATERIAL: EPDM RUBBER
FOR 1 HOLE OUTLETCONNECTORS
FOR 2 HOLEOUTLET
CONNECTORS
RECOMMENDED 1 HOLE AND 2 HOLEAL-CU COMPRESSION LUGS
WIRESIZE
#8 STR#6 STR#4 STR#2 STR1/0 STR2/0 STR3/0 STR4/0 STR
250 MCM300 MCM350 MCM400 MCM500 MCM
2 HOLECAT.NO.
SA8-NSA6-NSA4-NSA2-N
SA1/0-NSA2/0-NSA3/0-NSA4/0-NSA250-NSA300-NSA350-NSA400-NSA500-N
1 HOLECAT.NO.SA8-48SA6-48SA4-48SA2-48
SA1/0-48SA2/0-48SA3/0-48SA4/0-48SA250-48SA300-48SA350-48SA400-48
CFA500-48
CATALOGNUMBERFTN125-3FTN125-4FTN125-5FTN125-6FTN125-44
NO. OFOUTLETS
34568
L4-7/18
67-7/87-7/8
6
CATALOGNUMBER
FTN125-3NFTN125-4NFTN125-5NFTN125-6NFTN125-44N
NOTE: ROCKET SLEEVES NOT INCLUDED. USE SUFFIX “AWR” TO RECEIVE ASSEMBLED WITH ROCKETS. ORDER LUGS SEPARATELY.
“
2
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
3
“Flood-Seal”® 175 Series 4-Hole NEMA Spade Transformer Connectors
For dead fronting pad mount transformers with 4-hole NEMA spade secondary bushings.
“Flood-Seal” connectors permit the use of AL-CUstandard side formed 2-hole lugs.
“Flood-Seal” EPDM rubber insulating sleeves areavailable to fully insulate outlets.
All outlets are provided with 1/2” plated steel hexhead bolts and captive belleville washer.
Cable range from 4/0 to 1000 MCM aluminum orcopper. Lugs are ordered separately, see below.
All “Flood-Seal” connectors meet or exceed ANSIC119.4 requirements.
Maximum contact assures cooler operating, morereliable connections.
•
•
•
•
•
•
•
FTN175-4R
FTN175-22
Single Row style
Double Row style
ACCESSORIES
AL-NTN series aluminumlugs, 2/0 to 1000MCM,
are listed by Underwriter'sLaboratories, Inc.
See page 52
L-N series copper lugs,1/0 to 1000MCM, arelisted by Underwriter's
Laboratories, Inc.See page 58
“Flood-Seal” EPDM rubberinsulating sleeve covers the entire
conductor range. Order catalog # FS1175.
CATALOG NO. SPADE OUTLETS LENGTH
FTN175-4R RIGHT HAND 4 9-1/4"
FTN175-4L LEFT HAND 4 9-1/4"
FTN175-5R RIGHT HAND 5 11-3/4"
FTN175-5L LEFT HAND 5 11-3/4"
FTN175-6R RIGHT HAND 6 14-1/4"
FTN175-6L LEFT HAND 6 14-1/4"
CATALOG NO. OUTLETS LENGTH
FTN175-22 4 4-1/4"
FTN175-33 6 6-3/4"
FTN175-44 8 9-1/4"
FTN175-55 10 11-3/4"
FTN175-66 12 14-1/4"
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
4
Flood-Seal”®
Watertight 175 Stud Connectors
“ COMPACT DESIGN - conserves vault and manholespace, often eliminates the need for auxiliary buses.
CLAMP STYLE BASE - provides 3-1/4" of studcontact and eliminates the need for the jam nut.
Cable outlets are sealed WATERTIGHT whencovered with “Flood-Seal” EPDM insulating sleeves(see FS1175 below).
Ready to use - all NEMA drilled aluminum alloyoutlets provided with plated hex head bolts andcaptive Belleville washers.
•
•
•
•
Vertical Cable Leads
Horizontal Cable Leads
BELLEVILLEWASHERS
ARE CAPTIVEIN PVC
RUBBER GASKET PROVIDES SECURE CLOSURE BETWEEN CONNECTOR HALVES
BELLEVILLEWASHERS
ARE CAPTIVEIN PVC
RUBBER GASKET PROVIDES SECURE CLOSURE BETWEEN CONNECTOR HALVES
CONVENIENT MULTIPLE TAPCONNECTIONS TO POWERTRANSFORMERS AND NETWORK PROTECTORS.
NUMBEROF OUTLETS
8
1-1/2" STUD
FTT44-175-15
3" STUD
FTT44-175-30
CATALOG NUMBER
NUMBEROF OUTLETS
46810
1-1/2" STUD
FTH22-175-15FTH33-175-15FTH44-175-15FTH55-175-15
3" STUD
FTH22-175-30FTH33-175-30FTH44-175-30FTH55-175-30
H
9-3/8"11-7/8"14-3/8"16-7/8"
CATALOG NUMBER
Use “Flood-Seal” EPDM rubber insulatingsleeves for a watertight seal on outlets.
Order catalog numberFS1175
FTT and FTH connectors areavailable in copper, add
suffix CU to catalog number.
For special applications orgreater number of outletsthan those listed, please
consult the factory.
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
5
“Flood-Seal”® 95 Transformer Stud Connector
Disconnectable“Flood-Seal”® 95 Transformer Stud Connector
• Cable range from #8 to 350 MCM, aluminum or copper.
• Heavy PVC insulated aluminum body.
• “Flood-Seal” connectors comply with ANSI C119.4 specifications.
• Suitable jam nut supplied with each connector.
• All outlets except one are factory sealed with removable sealing caps.
• Cable range from #8 to 350 MCM, aluminum or copper.
• Heavy PVC insulated aluminum body.
• “Flood-Seal” connectors comply with ANSI C119.4 specifications.
• Suitable jam nut supplied with each connector.
• All outlets except one are factory sealed with removable sealing caps.
• Internal/external threaded bushing adapter allowsremoval of connector without disconnectingindividual cables.
5/8" STUDCATALOG NO.
FT95-2FT95-3FT95-4FT95-5FT95-6FT95-44FT95-55FT95-66
OUTLETS
2345681012
L
4"5-1/2"
7"8-1/2"
10"7"
8-1/2"10"
1" STUDCATALOG NO.
FT95-2-1FT95-3-1FT95-4-1FT95-5-1FT95-6-1FT95-44-1FT95-55-1FT95-66-1
5/8" STUDCATALOG NO.
FTU95-2FTU95-3FTU95-4FTU95-5FTU95-6FTU95-44FTU95-55FTU95-66
OUTLETS
2345681012
L
4"5-1/2"
7"8-1/2"
10"7"
8-1/2"10"
1" STUDCATALOG NO.
FTU95-2-1FTU95-3-1FTU95-4-1FTU95-5-1FTU95-6-1FTU95-44-1FTU95-55-1FTU95-66-1
EPDM RUBBER BUSHINGSTUD COVER SUPPLIED
EPDM RUBBER BUSHINGSTUD COVER SUPPLIED
See page 29 for connector kits containing center formed lug,EPDM rubber insulating sleeve or heat shrink sleeve.
See page 29 for connector kits containing center formed lug,EPDM rubber insulating sleeve or heat shrink sleeve.
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
Disconnectable – Doubles Cable Capacity in Half the Space – Fully Insulated
6
“Flood-Seal”® DF Secondary Transformer Connector
“Flood-Seal”® DH Compact Service Entrance Connector
5/8" TRANSFORMER STUD KITS FOR SINGLE SECONDARY CABLE – “FLOOD-SEAL” 125 SERIES
Fits all transformers with 5/8” studs.
Compact design reduces cantilever stress.
Fabricated from 6061-T6 aluminum alloy and insulated with EPDM rubber.
Sizes available accommodate from 2 to 8 secondary cables with a range from streetlight to 500 MCM*.
CATALOGNUMBER
DF22
DF33
DF44
OUTLETS
4
6
8
L
3-7/8"
5-3/4"
7-3/8"
•••
•
CATALOGNUMBER
DH22
DH33
DH44
OUTLETS
4
6
8
L
3-5/8"
5-1/2"
7-1/8"
REAAPPROVED
* ACCEPTS UP TO 500 MCM IF USING ONE SIDE OF DOUBLE OUTLET, UP TO 350 MCM MAX. WHEN BOTH SIDES ARE USED.ACCEPTS STANDARD SIDE FORMED LUGS, SOLD SEPARATELY. SEE ‘SA’ SERIES AL/CU COMMON DIE LUGS IN OUR COMPRESSION SECTION.
* ACCEPTS UP TO 500 MCM IF USING ONE SIDE OF DOUBLE OUTLET, UP TO 350 MCM MAX. WHEN BOTH SIDES ARE USED.ACCEPTS STANDARD SIDE FORMED LUGS, SOLD SEPARATELY. SEE ‘SA’ SERIES AL/CU COMMON DIE LUGS IN OUR COMPRESSION SECTION.
Economizes on enclosure space.
Cable range from streetlight conductor to 500 MCM*.
Accepts standard side formed lugs.
Maximum contact area assures cooler operating,more reliable joints.
••••
EPDM RUBBERINSULATING
SLEEVES INCLUDED
EPDM RUBBERINSULATING
SLEEVES INCLUDED
EACH KIT CONTAINS:1. EPDM BUSHING SHROUD NO. 2228-2 2. ALUMINUM CONNECTOR TOWER NO. 2154 3. PLATED HARDWARE
4. ALUMINUM AL-CU LUG 5. EPDM RUBBER INSULATING SLEEVE NO. CS2011
STRAIGHT DISCONNECTABLEDF158-4DF158-2DF158-1/0DF158-2/0DF158-3/0
COMPRESSION BARRELDF4-158DF2-158DF1/0-158DF2/0-158DF3/0-158
DF158-4/0DF158-250DF158-300DF158-350DF158-500
DF4/0-158DF250-150DF300-158DF350-158DF500-158
90º DISCONNECTABLEDF158-90-4DF158-90-2DF158-90-1/0DF158-90-2/0DF158-90-3/0
DF158-90-4/0DF158-90-250DF158-90-300DF158-90-350DF158-90-500
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
2
3
4
5
6
2
3
4
5
6
2
3
4
5
6
2
3
4
5
6
KB-2
KB-3
KB-4
KB-5
KB-6
SKB-2
SKB-3
SKB-4
SKB-5
SKB-6
DKB-2
DKB-3
DKB-4
DKB-5
DKB-6
DSKB-2
DSKB-3
DSKB-4
DSKB-5
DSKB-6
KB1-2
KB1-3
KB1-4
KB1-5
KB1-6
SKB1-2
SKB1-3
SKB1-4
SKB1-5
SKB1-6
DKB1-2
DKB1-3
DKB1-4
DKB1-5
DKB1-6
DSKB1-2
DSKB1-3
DSKB1-4
DSKB1-5
DSKB1-6
KBU-2
KBU-3
KBU-4
KBU-5
KBU-6
SKBU-2
SKBU-3
SKBU-4
SKBU-5
SKBU-6
DKBU-2
DKBU-3
DKBU-4
DKBU-5
DKBU-6
DSKBU-2
DSKBU-3
DSKBU-4
DSKBU-5
DSKBU-6
2-3/4"
4-1/8"
5-1/2"
6-7/8"
8-1/4"
2-3/4"
4-1/8"
5-1/2"
6-7/8"
8-1/4"
2-3/4"
4-1/8"
5-1/3"
6-7/8"
8-1/4"
2-3/4"
4-1/8"
5-1/2"
6-7/8"
8-1/4"
3-1/2"
5-1/4"
7"
8-3/4"
10-1/2"
3-1/2"
5-1/4"
7"
8-3/4"
10-1/2"
3-1/2"
5-1/4"
7"
8-3/4"
10-1/2"
3-1/2"
5-1/4"
7"
8-3/4"
10-1/2"
KB1-2N
KB1-3N
KB1-4N
KB1-5N
KB1-6N
SKB1-2N
SKB1-3N
SKB1-4N
SKB1-5N
SKB1-6N
DKB1-2N
DKB1-3N
DKB1-4N
DKB1-5N
DKB1-6N
DSKB1-2N
DSKB1-3N
DSKB1-4N
DSKB1-5N
DSKB1-6N
† DKB-2N
† DKB-3N
† DKB-4N
† DKB-5N
† DKB-6N
† DSKB-2N
† DSKB-3N
† DSKB-4N
† DSKB-5N
† DSKB-6N
ONE HOLE TWO HOLE
C A T A L O G N U M B E R S C A T A L O G N U M B E R SBAR TYPE
LENGTH
LENGTH
OUTLETS
Availableas
DisconnectableKee-Bar
Only
Available as
DisconnectableKee-Bar
Only
Kee-Bar
StuddedKee-Bar
DisconnectableKee-Bar
StuddedDisconnectable
Kee-Bar
7
Kee-Bars for ThreadedSecondary Studs• Economizes on enclosure space.
• Reduced cantilever stress on the transformer bushing.
• Accepts standard side formed lugs.
• Made of high conductivity aluminum.
• Exclusive "key-hole" shape for greater heat dissipation.
ON KBU AND SKBU, 5/8" END IS DISCONNECTABLE.
* ADD SUFFIX 'C' TO CATALOG NUMBER WHEN ORDERING WITH BUSHING COVER.† MAY BE CONVERTED TO ONE INCH STUD BY ORDERING CATALOG NUMBER 2250-1" STUD ADAPTER
* BushingCover 1" Stud5/8" Stud1" Stud5/8" Stud
Universal 1-hole for 5/8" OR 1" Stud
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
8
Copper SecondaryStud Adapters• Made from pure electrolytic copper and tin plated to resist corrosion.
• Accepts standard side formed AL-CU NEMA lugs.
• NEMA Pad Style marked with catalog number.
• Cable to Stud Style marked with catalog number, crimp area,installing dies and wire size.
NEMA PAD STYLE CABLE TO STUD STYLECATALOGNUMBER
2042-1
2042-2
2042-3
CATALOGNUMBER
2042-4
2042-5
2042-6
2042-7
CATALOGNUMBER
2042-8
2042-9
2042-10
2042-11
CATALOGNUMBER
2043-1
2043-2
2043-3
2043-4
2043-5
2043-6
2043-7
2043-8
2043-9
2043-10
STUDSIZE
5/8 - 11
1 - 14
1/2 - 13
STUDSIZE
5/8 - 11
1 - 14
1-1/4 - 12
1-1/2 - 12
STUDSIZE
5/8 - 11
1 - 14
1-1/4 -12
1-1/2 - 12
STUDSIZE
5/8 - 11
1/2 - 13
3/8 - 16
1 - 14
3/4 - 16
1 - 8
1/2 - 13
1/2 - 13
5/8 - 11
5/8 - 11
CABLESIZE
350
4/0
350
4/0
250
500
FOR VARIATIONS OR UNLISTED SIZESPLEASE CONSULT THE FACTORY
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
9
CopperTransformer Eye Bolt Adapter
Aluminum TransformerSpade Connector
• Connects to eye bolt transformer terminals.
• Provides a convenient means of gaining bolting pads for assembly of aluminum or copper terminals.
• Accepts copper or aluminum one-hole terminals and two hole NEMA drilled terminals.
• Adapters are made from high conductivitycopper and tin plated
• Adapts four-hole NEMA transformer pad to accept up to twelvetwo-hole NEMA drilled lugs and twelve two-hole stacking lugs.
• Cables are disconnectable.
• Made of high conductivity aluminum.
• Accepts copper or aluminum lugs.
CATALOGNUMBER
CEA2-50CEA4-50CEA4-75CEA6-50CEA6-75CEA6-100
FIGURE
1
2
3
PIN DIAMETER
1/2"
3/4"1/2"3/4"1"
H
6"5-1/4"5-3/4"5-1/4"
5-3/4"
L
1-1/4"3-3/4"
4"5-1/2"
5-3/4"
PINLENGTH
2-5/8"2-1/4"2-3/4"2-1/4"
2-3/4"
ALL BOLT HOLES ARE 9/16", SPACED ON 1-3/4" CENTER.
FOR TIN PLATING ADD SUFFIX 'TN' TO CATALOG NUMBER.
FIG. 1
FIG. 2
FIG. 3
CATALOGNUMBER
TSC4-6TSC4-8TSC4-10TSC4-12
L
TSC4-6TSC4-8TSC4-10TSC4-12
SPADE THICKNESS
3/8"
3/4"
NUMBER OF TAPBOLT HOLES
681012
TSC4-8
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
ABK 81-7024L
��������������������������������������������������
ABK 41000
NEW STYLES!
of trying to bend larger size cable inconfined areas.
Homac now offers a complete line of Lay-In Type connectors for transformer and pedestal applications.
NEW SIZES!
10
PEDESTAL
PAD MOUNTED
ABK 6350ABK 6600
easy-on fit for 5/8" & 1" studs
1-1/32"
1-3/8" 1-1/2"
7"
7" 8-7/8"
2-1/2"
6-5/16"
9/16 bolt holes drilled1-3/4" on center
1-1/4"
5-1/16"
9/16 bolt holes drilled1-3/4" on center
2-1/2"
8-5/16"
1" x 9/32" drilled, 1-3/4" on center.
2"
1-1/8" diameter
11
8816
ABK 81-7024RABK 81-7024LABK 881-7024
EZ KEEPER Series – New styles & sizes!
THREADED STUD
For Right or Left hand application.
OUTLETS
488
OUTLETS
66664
66
WIRE RANGE
#6 - 4/0#6 - 350 MCM#6 - 350 MCM#2 - 600 MCM
1/0 - 1000 MCM
WIRE RANGE
#6 - 4/0#6 - 350 MCM#2 - 600 MCM
STUD SIZE
5/8"5/8"1"1"1"
CATALOG #
ABKW 640-58ABKW 6350-58ABKW 6350-1ABKW 6600-1ABKW 41000-1
CATALOG #
ABK 41000ABK 441000ABK 81000
CATALOG #
AK 600 N
Pad Mount with Studs
WIRE RANGE
1/0 - 1000 MCM
WIRE RANGE
#2 - 600 MCM
#6 - 350 MCM#2 - 600 MCM
1/0 - 1000 MCM
CATALOG #
ABCK 640ABCK 6350ABCK 6600
1/2-13 STUDfor 1-3/4" oncenter drilled
pads
ABCK 640
ABCK 6350 ABCK 6600
OUTLETS CATALOG L MOUNTNUMBER HOLES
2 ZBT 1013-48 1"1
4 ZBT 2023-48 1-3/4"6 ZBT 3033-48 3" 28 ZBT 4043-48 4-3/4" 3
12 ZBT 6063-48 6-1/2" 4
2 ZBT 1013 1"2
4 ZBT 2023 1-3/4"6 ZBT 3033 3" 48 ZBT 4043 4-3/4" 6
12 ZBT 6063 6-1/2" 8
2 ZBT 1017 1-5/8" 24 ZBT 2027 3" 46 ZBT 3037 4-5/16" 68 ZBT 4047 6-1/2" 8
12 ZBT 6067 8-1/4" 12
MOUNTHOLES
36486
128
10128
1212
CATALOGNUMBER
ABT4500-48ABT4500
ABT6500-48ABT6500
ABT8500-48ABT8500ABT4750ABT6750ABT8750
ABT41000ABT61000ABT81000
CABLERANGE
2-500
1/0-750
500-1000
STYLE
121212
3
3
OUTLETS
4
6
8
468468
LENGTH
4-3/4"
6-7/8"
9-1/8"
6-1/2"8-1/4"
10-11/16"6-1/2"9-3/4"
12-1/4"
CABLERANGE
6-250
6-350
STYLE
121212121212
OUTLETS
4
6
8
4
6
8
CATALOGNUMBER
ABT440-48ABT440
ABT640-48ABT640
ABT840-48ABT840
ABT4350-48ABT4350
ABT6350-48ABT6350
ABT8350-48ABT8350
LENGTH
4-5/8"
6"
8"
4-5/8"
6-1/8"
8-1/8"
MOUNTHOLES
364848364848
12
Set Screw Bar Transformer Connectors ABT Series
Standard NEMA Bolt Hole Spacing
Designed for installation on both standard NEMA two or four bolthole spade terminals.
HIGH STRENGTH ALUMINUM ALLOY – constant bolting pressureon conductors is maintained.
SPECIAL OPTIONS ARE AVAILABLE, PLEASE CONSULT THE FACTORY. INSULATING BOOTS ARE AVAILABLE, CONSULT THE FACTORY.
STYLE 1
STYLE 3
STYLE 2
MAXIMUM CONDUCTOR CONTACT PRESSURE – ball bottomscrew design breaks up interstrand oxides.
TESTING – meets or exceeds ANSI C119.4 Class “A” tests.
Dual rated for use with aluminum and copper conductors.
•
•
•
••
• Use instead of compression lugs, easier andquicker to install.
• Compact Zeebar design halves cantilever stress, doubles cable capacity.
• Designed for installation on NEMA bolt hole and in-line spade terminals.*
• Made of high strength aluminum alloy.
• Cable range from #12 to 350 MCM or 1/0 to 750 MCM.
• All outlets provided with ball bottom set screws, accepts 5/16 hex wrench.
• Exceeds ANSI C119.4 specifications.
ZBT Series Set Screw BarTransformer Connectors
*CONSULT FACTORY FOR INSULATING BOOTS AND SPECIAL APPLICATIONS.
STYLES AND CABLE RANGE
ONE HOLE
TWO HOLE
TWO HOLE
#12 TO 350 MCM
#12 TO 350 MCM
1/0 TO 750 MCM
4-7/8"
6-3/8"
3-1/4"
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
13
UNIVERSAL SERIES – for 5/8” and 1” studs
58 SERIES – for 5/8” studs only
1 SERIES – for 1” studs only
12to
3506to
500
NOTE: For compound, add suffix C (i.e. Z 2043-SLC). Consult factory for sizes not listed.
CATALOG STUD PVCCABLE RANGE OUTLETS NUMBER SIZE L H BOOT NO.
6 Z4023-1SL 4-3/4” EZ5912-2
8 Z5033-1SL 1” 5-3/4 2-7/8” EZ5912-3
6 Z4025-1SL 5-1/8” EZ5912-3
8 Z5035-1SL 5-3/4" EZ5912-3
CATALOG STUD PVC POLYETHYLENECABLE RANGE OUTLETS NUMBER SIZE L H BOOT NO. BOOT NO.
12 6 Z2044SL 3-15/16” EZ5912-1to 8 Z3054SL 4-3/4” 1-15/16” EZ5912-54/0 10 Z4064SL 5/8” 5” EZ5912-5 PB-1
12 to 6 Z2043-58SL 4-1/4” 2-3/8” EZ5912-1350 8 Z3053-58SL 5-1/4” EZ5912-5
CATALOG STUD PVC POLYETHYLENECABLE RANGE OUTLETS NUMBER SIZE L* H BOOT NO. BOOT NO.
12 6 Z3033-USL 5-3/8” EZ5912-3PB-2Tto
8 Z4043-USL 6-3/8” EZ5912-73506 6 Z3035-USL 5/8” 5-11/16”
2-7/8”EZ5912-3 -to &
500 8 Z4045-USL 1” 6-13/16” EZ5912-7 -1/0 6 Z3037-USL 6-1/16” EZ5912-8 -to 3-1/8”750 8 Z4047-USL 7-5/16” EZ5912-9 -
Z3033-USL WITHDROP-ON BOOT SHOWN • EZ on space - copact design doubles cable capacity, halves cantilever stress.
• EZ to install - all screws on top. Proven ball bottom set screws. 5/16" hex wrenchdoes it all - including streetlight option.
• EZ on EZ off - connector available in three sizes, #6-350MCM and #6-500MCMand 1/0-750MCM.
• EZ adaptability - universal version fits both 5/8" or 1" studs. Also available are connectors to fit either 5/8" or 1" stud sizes.
• EZ to insulate - clear PVC drop on or integral boots are available. For integral boot, see ZVW series on the following page. Economical drop on polyethyleneboots are also available.
• Fully tested - to exceed specifications of ANSI C119.4.
Homac’s
PATENTED
Compact! Easy to Install!Disconnectable Secondary Transformer Connector
®
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
CABLE OUTLETS INSULATED STUDRANGE CAT.NUMBER SIZE
4 ZVB 2023 2-1/4"6 ZVB 3033 3-1/4"8 ZVB 4043 4-1/4"10 ZVB 5053 5-1/4"4 ZVB 2025 2-7/16"6 ZVB 3035 3-9/16"8 ZVB 4045 4-11/16"10 ZVB 5055 5-13/16"
14
Compact! Easy to Install!Disconnectable Secondary Transformer Connector
• EZ on space – compact design doubles cable capacity, halvescantilever stress.
• EZ to install – all screws on top. 5/16" hex ball bottom set screws.
• EZ on EZ off – connector available in three sizes, #12-350MCM,#6-500MCM and 1/0-750MCM.
• EZ adaptability – universal version fits both 5/8" and 1" studs. Alsoavailable are connectors to fit either 5/8" or 1" stud sizes.
• Fully insulated with a clear, lock-on PVC boot.
• Fully tested to exceed specifications of ANSI C119.4.
Homac’s Lock-on Insulator PATENTED
12 to350
6 to500
12to4/0
12 to350
1 SERIES – for 1" studs only
12to
3506to
5001/0to
750
UNIVERSAL SERIES – for 5/8" and 1" studs
NOTE: ADD "C" SUFFIX TO CATALOG NO. FOR COMPOUND(i.e. ZVW2044SLC or ZVB2023C). ADD "K" SUFFIXFOR KIT CONTAINING 2 INSULATED AND 1 UNINSULATEDCONNECTOR.
CONSULT FACTORY FOR SIZES NOT LISTED.
12to
350
6to
500
PRE-INSULATED AND UNINSULATED PEDESTAL CONNECTOR
58 SERIES – for 5/8" studs only
CABLE OUTLETS CATALOG STUD LRANGE NUMBER SIZE
6 ZVW 3033-USL 5-3/8"
8 ZVW 4043-USL5/8"
6-3/8"
6 ZVW 3035-USL & 5-11/16"
8 ZVW 4045-USL 1" 6-13/16"
6 ZVW 3037-USL 6-3/8"
8 ZVW 4047-USL 7-5/8"
CABLE OUTLETS CATALOG STUD LRANGE NUMBER SIZE
6 ZVW 4023-1SL 4-3/4"
8 ZVW 5033-1SL1"
5-3/4"
6 ZVW 4025-1SL 5-1/8"
8 ZVW 5035-1SL 6-1/4"
CABLE OUTLETS CATALOG STUD LRANGE NUMBER SIZE
6 ZVW 2044SL 3-15/16"8 ZVW 3054SL 4-3/4"10 ZVW 4064SL 5/8" 5"6 ZVW 2043-58SL 4-3/8"8 ZVW 3053-58SL 5-3/8"
UNINSULATEDCAT.NUMBER
ZBC 2023ZBC 3033ZBC 4043ZBC 5053ZBC 2025ZBC 3035ZBC 4045ZBC 5055
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
CABLE CATALOG STUDRANGE
OUTLETSNUMBER SIZE
L H
#12SOL 6 LRT33UW 5/8" 3"to & 2-1/2"
350MCM 8 LRT44UW 1" 4"
15
Disconnectable SecondaryTransformer Connector
Fully insulated waterproof transformer connector.
Complete dead front clear insulator locks in place byraised set screws or installation of the first conductor.
EPDM rubber cable adapters accommodate #12sol.to 250MCM - for 300 to 350MCM remove cable adapter.
Compact design doubles cable capacity in half thespace and reduces cantilever stress, lessening theincidence of leaky bushings.
••
•
•
SEALINGGLAND
BALL BOTTOMSET SCREW
EPDM RUBBERCABLE ADAPTERS
CABLE CATALOG STUDRANGE
OUTLETSNUMBER SIZE
L H
#12SOL 4 LRT2258 2"to 6 LRT3358 5/8" 3" 2-1/2"
350MCM 8 LRT4458 4"
#12SOL 4 LRT2210 2"to 6 LRT3310 1" 3" 2-1/2"
350MCM 8 LRT4410 4"
UNINSULATED CONNECTOR
CABLE CATALOG STUDRANGE
OUTLETSNUMBER SIZE
L H
#12SOL 6 LRT33U 5/8" 3"to & 2-1/2"
350MCM 8 LRT44U 1" 4"
WATERPROOF CONNECTOR KIT
UNINSULATED UNIVERSAL CONNECTOR
DEAD FRONT CONNECTOR KIT
CBB3344 Clear insulatingboot accommodates 4, 6,and 8 outlet connectors for5/8" or 1" studs.
KIT INCLUDES:• UNIVERSAL CONNECTOR• CLEAR LOCK-ON INSULATOR• SCREW PORT INSULATING CAPS
CABLE CATALOG STUDRANGE
OUTLETSNUMBER SIZE
L H
#12SOL 6 LRT33UX 5/8" 4-3/8"to & 4-3/8"
350MCM 8 LRT44UX 1" 5-3/8"
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
16
RAU Series Universal Secondary Transformer Connector with See-Thru Insulator
Universal - fits 5/8" and 1" studs.
Disconnectable - easy on or off.
Versatile design allows right or left hand installation.
Space Saver - first cables are installed directlyunderneath stud, keeping cables closer to tank wall.
Reduces cantilever stress on bushing.
Pliable PVC insulator remains easy to work within all weather conditions.
For streetlight add suffix "SL".For oxide inhibiting compound add suffix "C".
CABLE RANGE OUTLETS † CATALOG NUMBER INSULATOR LENGTH
6-500 MCM
4
6
8
RAU 4500
RAU 6500
RAU 8500
5-1/2
6-7/8
8-7/8
••••
••
For see-thru insulator, specify "with cover".† Catalog number for Uninsulated connector only.
QUICKDISCONNECTCAT.NUMBER
CSW 4350CSW 6350CSW 8350
CSW 4350-1CSW 6350-1CSW 8350-1
CSW 4350-58CSW 6350-58CSW 8500-58
CSW 4500CSW 6500CSW 8500
SCREW ONSTYLE
CAT.NUMBER
CSS 4350CSS 6350CSS 8350
CSS 4350-1CSS 6350-1CSS 8350-1
CSS 4350-58CSS 6350-58CSS 8500-58
CSS 4500CSS 6500CSS 8500
INSULATORLENGTH
5-11/16"7-1/16"9-1/16"
11-1/16"5-1/16"7-1/16"9-1/16"
11-1/16"5-3/16"7-3/16"9-3/16"
11-3/16"
OUTLETS
468468468468
STUDSIZE
5/8"
1"
5/8"
1"
CABLERANGE
#12 - 350MCM
#2 - 500MCM
CSW Series Disconnectable SecondaryTransformer Connector with See-Thru Insulator
Safe - clear PVC insulating boot features self sealing wrench outlets, self adjusting cable outlets.
Designed for easy disconnectability from the transformer.
Dual rated for use with aluminum and copper conductors.
Fully Tested - exceeds ANSI C119.4 specifications.
•
•••
FOR OXIDE INHIBITING COMPOUND -ADD SUFFIX "C" TO CATALOG NUMBER.
FOR STREETLIGHT OUTLET - ADDSUFFIX "SL" TO CATALOG NUMBER.
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
17
���������������� ������ ����CLEARLY INSPECTABLE - clear see through insulator, rated 480V./mil.
CLEARLY NO LOST PARTS - integral wrench outlet covers.
CLEARLY VERSATILE - right or left hand installation.
CLEARLY WIDEST RANGE - #12 S/L to 350 MCM.
CLEARLY SUPERIOR - fully tested to comply with ANSIC119.4 specifications.
CLEARLY ECONOMICAL - polypropylene cover insulates 2, 4, 6 and 8 outlet connectors.
REA approved. PATENTED
strip length not critical -CLEARLY FASTER
INSTALLATION
self adjusting cable outlets -CLEARLY SAFER
OUTLETS
2468
WIRERANGE
#12 S/LTO
350 MCM
INSULATORLENGTH
10-3/16"
CATALOGNUMBER
LRT 2350LRT4350LRT6350LRT8350
Right or Left HandRubber Insulated DisconnectableTransformer Connector PATENTED
Optional watertight cable and set screw ports.
Disconnectable – fully insulated with EPDM rubber.
Reduces inventory – unique design allows easy rightor left hand installation in the field.
Aluminum cable stop plate provides double protection from sharp cable ends.
Wide cable range – #12 to 350 MCM.
“Ball Bottom” screws aid the break-up of aluminum oxides.
•••
•
••
Factory assembled for right handinstallation - but easily changed toleft hand application in the field.
Each connector comes withcomplete instructions.
WIRE SIZE
#12 TO350 MCM
CATALOGNUMBER
* LRTR-4W
* LRTR-6W
* LRTR-8W
OUTLETS468
STUDSIZE
5/8
L7”9”11”
CATALOGNUMBERLRTR-4LRTR-6LRTR-8
* WATERTIGHT CABLE AND SCREW PORTS
LRTR-WSTYLE LRTR
STYLE
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
18
CABLERANGE
6-250
12-350
6-500
1/0-750
OUT-LETS
4
6
8
4
6
8
4
6
8
4
6
8
STUDSIZE
5/8"
5/8"
1"
1"
CATALOGNUMBER
ABW40-22
ABW40-33
ABW40-44
ABW350-22
ABW350-33
ABW350-44
ABW500-22
ABW500-33
ABW500-44
ABW750-22
ABW750-33
ABW750-44
FIG.2DOUBLE ROW BARDISCONNECTABLE
WIDTH
2-1/2
2-1/2
2-3/4
3-1/4
LENGTH
3-1/2
4-1/4
5-1/16
4
4/7/8
5-7/16
4-7/16
5-7/16
6-7/16
4-3/4
6-1/8
7-7/16
BOOTNUMBER
SB16
SB16
SB2163-38
SB2151
SB2158
SB2158
SB2163-7
Set Screw BarTransformer ConnectorsABW Series
DESIGNED for easy disconnectability from transformer secondary studs.
OXIDE INHIBITING COMPOUND provided in stud hole.
HIGH STRENGTH ALUMINUM ALLOY – constant bolting pressure onconductors is maintained.
MAXIMUM CONDUCTOR CONTACT PRESSURE – ball bottom screwdesign breaks up interstrand oxides.
TESTING – meets or exceeds ANSI C119.4 Class “A” tests.
INSULATING BOOTS – sold separately.
DUAL RATED for use with aluminum and copper conductors.
••
•
•
•••
CABLERANGE
6-250
12-350
6-500
1/0-750
OUT-LETS
2
3
4
5
6
7
8
2
3
4
5
6
7
8
2
3
4
5
6
7
8
2
3
4
STUDSIZE
5/8"
5/8"
1"
1"
CATALOGNUMBER
ABW240
ABW340
ABW440
ABW540
ABW640
ABW740
ABW840
ABW2350
ABW3350
ABW4350
ABW5350
ABW6350
ABW7350
ABW8350
ABW2500
ABW3500
ABW4500
ABW5500
ABW6500
ABW7500
ABW8500
ABW2750
ABW3750
ABW4750
LENGTH
3-1/8
3-7/8
4-11/16
5-1/2
6-1/4
7
7-13/16
3-1/2
4-1/2
5-1/2
6-1/2
7-1/2
8-1/2
9-1/2
4-1/16
5-1/16
6-1/16
7-1/16
8-1/16
9-1/16
10-1/16
5-1/16
6-7/16
7-3/4
BOOTNUMBER
SB17
SB11
SB14
SB17
SB11
SB14
SB2160
SB2147
SB2163-38
SB2163-7
SB2157
SB2160
SB2147
SB2163-38
SB2120
FIG.1SINGLE LINE BAR
DISCONNECTABLE
FIG.1 ContinuedSINGLE LINE BAR
DISCONNECTABLE
CABLERANGE
1/0-750
OUT-LETS
5
6
7
8
STUDSIZE
1"
CATALOGNUMBER
ABW5750
ABW6750
ABW7750
ABW8750
LENGTH
9-1/8
10-1/2
11-13/16
13-1/8
BOOTNUMBER
SB2157
SB2160
SB2163-10
PLEASE CONSULT THE FACTORY FOR SPECIAL APPLICATIONS AND STUD SIZES.
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
19
Set Screw BarTransformer ConnectorsABS Series• DESIGNED for use on transformer secondary threaded studs.
• OXIDE INHIBITING COMPOUND - provided in stud hole.
• HIGH STRENGTH ALUMINUM ALLOY - constant bolting pressure on conductors is maintained.
• MAXIMUM CONDUCTOR CONTACT PRESSURE - ball bottom screw design breaks up interstrand oxides.
• TESTING - meets or exceeds ANSI C119.4 Class “A” tests.
• INSULATING BOOTS - sold separately.
• OPTIONS: Please consult factory for special applications and stud sizes.
FIG. 1
SINGLE LINE BAR
CABLE OUT- STUD CATALOG BOOTRANGE LETS SIZE NUMBER LENGTH NUMBER
2 ABS2750 4-11/163 ABS3750 6
SB17
4 ABS4750 7-3/8 SB21201/0-750 5 1" ABS5750 8-11/16 SB2157
6 ABS6750 10-1/16SB2160
7 ABS7750 11-3/88 ABS8750 12-3/4 SB2163-10
FIG. 2
DOUBLE ROW BAR
CABLE OUT- STUD CATALOG BOOTRANGE LETS SIZE NUMBER LENGTH WIDTH NUMBER
4 ABS40-22 3-1/16
6-250 6 5/8" ABS40-33 3-7/8 2-1/2
8 ABS40-44 4-11/16
4 ABS350-22 3-5/8SB16
12-350 6 5/8" ABS350-33 4-1/2 2-1/2
8 ABS350-44 5-7/16
4 ABS500-22 3-15/16SB2151
6-500 6 1" ABS500-33 4-15/16 2-3/4
8 ABS500-44 5-15/16 SB2163-6
4 ABS750-22 4-1/4 SB2151
1/0-750 6 1" ABS750-33 5-9/16 3-1/4SB2163-6
8 ABS750-44 6-15/16
FIG. 1
SINGLE LINE BAR
CABLE OUT- STUD CATALOG BOOTRANGE LETS SIZE NUMBER LENGTH NUMBER
2 ABS240 2-7/8 Refer to
3 ABS340 3-5/8 Factory
4 ABS440 4-7/16
6-250 5 5/8" ABS540 5-1/4SB17
6 ABS640 6SB11
7 ABS740 6-13/16
8 ABS840 7-9/16 SB14
Refer to2 ABS2350 3-1/4 Factory
3 ABS3350 4-1/4
SB174 ABS4350 5-1/4
12-350 5 5/8" ABS5350 6-1/4
6 ABS6350 7-1/4SB11
7 ABS7350 8-1/4
8 ABS8350 9-1/4 SB14
2 ABS2500 3-13/16
3 ABS3500 4-13/16SB17
4 ABS4500 5-13/16
6-500 5 1" ABS5500 6-13/16 SB2120
6 ABS6500 7-13/16SB2157
7 ABS7500 8-13/16
8 ABS8500 9-13/16 SB2160
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
20
Set Screw BarTransformer ConnectorsABN Series
Designed for installation on standard NEMA spade terminals.
HIGH STRENGTH ALUMINUM ALLOY – constant bolting pressure onconductors is maintained.
MAXIMUM CONDUCTOR CONTACT PRESSURE – ball bottom screwdesign breaks up interstrand oxides.
TESTING – meets or exceeds ANSI C119.4 Class “A” tests.
INSULATING BOOTS – sold separately.
DUAL RATED for both aluminum and copper.
•
•
•••
•
CABLERANGE
6-250
6-350
CABLERANGE
2-500
1/0-750
OUTLETS
2
3
4
5
6
7
8
2
3
4
5
6
7
8
OUTLETS
2
3
4
5
6
7
8
2
3
4
5
6
7
8
CATALOGNUMBER
ABN240
ABN340
ABN440
ABN540
ABN640
ABN740
ABN840
ABN2350
ABN3350
ABN4350
ABN5350
ABN6350
ABN7350
ABN8350
CATALOGNUMBER
ABN2500
ABN3500
ABN4500
ABN5500
ABN6500
ABN7500
ABN8500
ABN2750
ABN3750
ABN4750
ABN5750
ABN6750
ABN7750
ABN8750
LENGTH
4-3/4
5-1/2
6-5/16
7-1/16
7-7/8
8-5/8
9-7/16
4-15/16
5-7/8
6-3/4
7-11/16
8-9/16
9-1/2
10-7/16
LENGTH
5-5/16
6-5/16
7-5/16
8-5/16
9-5/16
10-5/16
11-5/16
5-15/16
7-1/4
8-5/8
9-15/16
11-1/4
12-5/8
13-15/16
BOOTNUMBER
SB17
SB11
SB14
SB17
SB11
SB14
2160
BOOTNUMBER
SB17
SB11
SB14
2160
2163
2163-3
2120
2160
2163-3
PLEASE CONSULT THE FACTORY FOR SPECIAL APPLICATIONS.
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
21
Homac’s EPDM Rubber�����������Bounces back in tough weather!
• EPDM RUBBER – will not crack fromcold embrittlement – will not softenwith heat – will not cold flow.
• FLEXIBLE LOCKING RIBS –prevent accidental removal of EPDMboot.
• TWO STYLES – cover a wide varietyof connector types.
FB33 STYLE
FB6-L STYLE
• DOUBLE THICK TOP – for extra protection.
• CAT. NO. FB33 fits these Homac pedestal connectors.ABC40-22 ABC350-44 AVH200-48 APH250ABC40-33 ABC500-22 APH2/0 APH300ABC40-44 ABC500-33 APH3/0 APH350ABC350-22 ABC750-22 APH4/0 APH500ABC350-33
• ALLOWS CLEARANCE – for protruding conductor ends.
• CAT. NO. FB6-L fits these Homac pedestal connectors.ABC4350 ABC4500ABC5350 ABC5500ABC6350 ABC6500
OTHER EPDM BOOTS
PEDESTAL APPLICATIONS TRANSFORMERAPPLICATIONS
FBV4N (orange) FB4N-B (black) BBV4N (orange)
PLEASE CONSULT FACTORY FOR ANY BOOTS NOT LISTED.
Insu
lating
Bo
ots
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
22
POLYETHYLENEBOOTS
ALL DIMENSIONS GIVEN ON THIS PAGEARE INSIDE DIMENSIONS.
TRANSFORMERAPPLICATIONS
PEDESTALAPPLICATIONS
FIG. 3
FIG. 4
FIG. 1
FIG. 2
ALL BOOTS HAVE ANOMINAL WALL THICKNESSOF 1/8 INCH.
PVC (poly-vinyl chloride)BOOTS
H
H
H-1
H H-1
H H-1
H H-1
PLEASE CONSULT FACTORY FOR ANY BOOTS NOT LISTED.
CATALOGNUMBER H H-1 LENGTH WIDTH
BB-10 3-5/16" 1-3/8" 4-1/8" 2-1/8"BB-11 2-7/8" 1-3/8" 5-7/8" 2-1/8"BB-12 3-3/4" 1-7/8" 7-3/4" 2-1/4"BB-13 3-3/4" 1-7/8" 5-15/16" 2-3/4"BB-14 3-3/4" 1-7/8" 8-5/8" 2-3/4"BB-15 3-3/4" 1-7/8" 11-11/16" 2-3/4"
CATALOGNUMBER H H-1 LENGTH WIDTH
BB-17 6-7/8" 2-1/8" 3-1/8" 3-1/16"
CATALOGNUMBER H H-1 LENGTH WIDTH
SB-16 3" 1" 5-3/8" 3-1/2"SB-17 3-3/4" 1-7/8" 5-5/16" 2-3/4"
CATALOGNUMBER H H-1 LENGTH WIDTH
SB-11 2-1/16" 1-1/16" 8-1/8" 2"SB-14 2-1/16" 1-1/16" 9-15/16" 2"
CATALOGNUMBER H LENGTH WIDTH
SB-2120 5-3/4" 8-3/4" 2-1/2"
SB-2144 9" 3-1/4" 4-1/2"
SB-2144-BG 8-7/8" 3-1/16" 3"
SB-2147 6-1/8" 5-1/2" 2-1/2"
SB-2150 12" 4" 5-1/2"
SB-2151 12" 5-1/2" 4"
SB-2157 7-3/4" 9-3/4" 2-3/4"
SB-2158 12" 7" 4-5/8"
SB-2159 11-3/4" 9-3/4" 4-5/8"
SB-2160 5-7/8" 12" 2-3/4"
SB-2163-2 12" 8-3/4" 5"
SB-2163-3 11-7/8" 12-3/8" 5-3/16"
SB-2163-4 11-7/8" 14" 5-1/2"
SB-2163-5 10" 7" 4-5/8"
SB-2163-6 8-7/8" 7" 4-5/8"
SB-2163-7 7-7/8" 8" 3"
SB-2163-10 7-3/4" 13-3/4" 5"
SB-2163-12 8-1/8" 8-3/4" 5"
SB-2163-38 5-1/4" 7-1/8" 3"
CATALOGNUMBER FIG. H LENGTH WIDTH
PB-1 1 4" 6-1/4" 2-7/8"
PB-2T 2 4" 8" 4-3/16"
PB-2 3 8" 4" 4-3/16"
PB-1P 4 4" 6-1/4" 2-7/8"
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
23
FIG. 2
DOUBLE ROW BAR
CABLE CATALOG BOOTRANGE OUTLETS NUMBER LENGTH WIDTH NUMBER
4 ABC40-22 1-5/8 BB176-250 6 ABC40-33 2-7/16 2
8 ABC40-44 3-3/16 FB33 *4 ABC350-22 2-1/8 BB17
12-350 6 ABC350-33 3 2-1/2
8 ABC350-44 3-15/16 2-3/8FB33 *
4 ABC500-22 2-1/16 FB33 *6-500 6 ABC500-33 3-1/16 2-3/4
8 ABC500-44 4-1/16 – **4 ABC750-22 2-3/4
1/0-750 6 ABC750-33 4-3/16 3-1/4 – **8 ABC750-44 5-9/16
FIG. 1
SINGLE LINE BAR
CABLE CATALOG BOOTRANGE OUTLETS NUMBER LENGTH NUMBER
2 ABC2750 2-3/4 BB103 ABC3750 4-3/16
BB134 ABC4750 5-9/16
1/0-750 5 ABC5750 7 BB126 ABC6750 8-3/8 BB147 ABC7750 9-13/16
BB158 ABC8750 11-3/16
FIG. 1
SINGLE LINE BAR
CABLE CATALOG BOOTRANGE OUTLETS NUMBER LENGTH NUMBER
2 ABC240 1-11/16
3 ABC340 2-9/16 BB10
4 ABC440 3-7/16
6-250 5 ABC540 4-5/16BB11
6 ABC640 5-3/16
7 ABC740 6-1/16BB12
8 ABC840 6-15/16
2 ABC2350 2
3 ABC3350 3 BB10
4 ABC4350 4
12-350 5 ABC5350 5
6 ABC6350 6BB11
7 ABC7350 7
8 ABC8350 8BB12
2 ABC2500 2-1/16 BB10
3 ABC3500 3-1/16
4 ABC4500 4-1/16
6-500 5 ABC5500 5-1/16BB11
6 ABC6500 6-1/16 BB12
7 ABC7500 7-1/16BB14
8 ABC8500 8-1/16
Set Screw BarPedestal ConnectorsABC Series• DESIGNED for use in above grade pedestals.
• HIGH STRENGTH ALUMINUM ALLOY - constant bolting pressure on conductors is maintained.
• MAXIMUM CONDUCTOR CONTACT PRESSURE - ball bottom screw design breaks up interstrand oxides.
• TESTING - meets or exceeds ANSI C119.4 Class “A” tests.
• INSULATING BOOTS - sold separately.
• OPTIONS: Please consult factory for special applications.
*EPDM FLEXI-BOOT, SEE CATALOG PAGE 21** CONSULT FACTORY.
Ped
estal and
H
and
ho
le Co
nn
ectors
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
24
CLR Series Insulated Pedestal ConnectorINSPECTABLE - transparent polypropylene insulator rated 480V./mil.
NO LOST PARTS - integral wrench outlet covers.
SAFER - connector securely locked in cover, cable outlets self adjust.
WIDEST RANGE - “ball bottom” screw - #12 S/L to 350 MCM.
FASTER INSTALLATION - strip length not critical.
SUPERIOR - fully tested to comply with ANSI C119.4 specifications.
OUTLETS
456
CATALOGNUMBER
CLR4350CLR5350CLR6350
WIRERANGE
#12 S/Lto
350 MCM
LENGTH WITHINSULATOR
7-1/4"
Insulated Multi-Cable Connector Blocks
CATALOGNUMBER
CSB 2/0-2CSB 2/0-3CSB 2/0-4CSB 2/0-5CSB 2/0-6
NO. OFCIRCUITS
23456
APPRX.LENGTH
1-3/8"2-3/32"2-13/16"3-9/16"4-9/32"
WIRERANGE
#14-2/0
Made from high quality aluminum and insulated with clear PVC.
Dual rated for use with copper or aluminum conductor.
Rated 600V. max. and meets or exceeds ANSI C119.4 specifications.
CATALOGNUMBER
CSB 250-2CSB 250-3CSB 250-4CSB 250-5CSB 250-6CSB 250-7CSB 250-8
NO. OFCIRCUITS
2345678
APPRX.LENGTH
1-7/8"2-27/32"3-13/16"4-25/32"5-3/4"
6-23/32"7-11/16"
WIRERANGE
#6 - 250 MCM
CATALOGNUMBER
CSB 350-2CSB 350-3CSB 350-4CSB 350-5CSB 350-6CSB 350-7CSB 350-8
NO. OFCIRCUITS
2345678
APPRX.LENGTH
1-31/32"2-31/32"
4"5-1/32"6-1/32"7-1/16"8-3/32"
WIRERANGE
#10 - 350 MCM
CATALOGNUMBER
CSB 500-2CSB 500-3CSB 500-4CSB 500-5CSB 500-6CSB 500-7CSB 500-8
NO. OFCIRCUITS
2345678
APPRX.LENGTH
2-15/32"3-3/4"
5"6-9/32"7-17/32"8-13/16"10-3/32"
WIRERANGE
#6-500 MCM
••••••
•••
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
CATALOGNUMBER
SECONDARYCABLE MAIN
2/0
3/0
4/0
250
300
350
400
500
750
25
Homac’s Hub System The First Pedestal ConnectorsDesigned Exclusively for URD• Compact Space Saving Design
• Disconnectable
• Low Installed Cost
PATENTED
TYPE AVH
TYPE APH NOTE: ALL ALUMINUM HUB CONNECTORS ARE FURNISHED WITH 6 PLATED STEEL BOLTS & BELLEVILLEWASHERS. USE INSULATING HUB BOOT PB-2 FOR BOTH AVH & APH.
“Flood-Seal” 125Insulated Hub
®
Heat ShrinkSealing Tube
CS2011
RECOMMENDED ALUM OR CU LUGS
WIRESIZE
#12- #10#8 STR#6 STR#4 STR#2 STR1/0 STR2/0 STR3/0 STR4/0 STR
250 MCM300 MCM350 MCM
CU LUGCAT.NO.HL10-48
L8-48L6-48L4-48L2-48
L1/0-48L2/0-48L3/0-48L4/0-48L250-48L300-48L350-48
AL LUGCAT.NO.
––
AL6-14TNAL4-14TNAL2-14TN
AL1/0-48TNAL2/0-48TNAL3/0-48TNAL4/0-48TNAL250-48TNAL300-48TNAL350-48TN
AL LUGCAT.NO.
–SA8-48SA6-48SA4-48SA2-48
SA1/0-48SA2/0-48SA3/0-48
SA4/0-48
SA300-48SA350-48
• Uses Standard One Hole Lugs(See chart below for lug recommendations.)
• Wide Conductor Range - #12-350 MCM
CATALOGNUMBERAVH200
CATALOGNUMBERAPH4/0APH350APH500APH750
CABLE RANGE#12-350 MCM
CABLE RANGE
#12-350 MCM
SECONDARYCABLE MAIN
4/0350500750
COMMON DIE
WITHOUT SECONDARYCABLE MAIN
ORDER CATALOG NO.FSH6
SUB-HUB version of the “Flood-Seal” 125 groupcan be direct buried or installed in an enclosure.
Connectors are factory dielectrically tested.
Wire range - 2/0 to 750 MCM secondary cable mainand #12 to 350 MCM service.
Heavy PVC insulated aluminum body.
EPDM “Flood-Seal” insulating sleeve/cap available,ordered separately.
•
••
••
Accessories
“Flood-Seal” EPDMrubber cap/sleeve
HS1506
FSH2/0-125
FSH3/0-125
FSH4/0-125
FSH250-125
FSH300-125
FSH350-125
FSH400-125
FSH500-125
FSH750-125
NEW! Keeper Style Mechanical Hub ConnectorCATALOG NUMBER : AVHK-6350
WIRE RANGE: #12 TO 350 MCM.
MATERIAL: High Conductivity Aluminum
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
26
“Flood-Seal”® 175Connectors
NEW–BETTER THAN EVER!NOW EPDM RUBBERIZED – Precision molded for uniform quality.Proven in over 10 million field applications.
DIMENSIONAL STABILITY ACHIEVED – Connector now extruded highconductivity electrolytic aluminum.
VERSATILITY AND COMPRESSION CONNECTOR RELIABILITY –Uses standard aluminum or copper NEMA drilled lugs in all conductorsizes up to 1000 MCM.
ACCOMMODATES LIMITER TERMINALS – Homac 120/128 Volt ACLimiter Terminals and 265/460 Volt AC Limiter Terminals may also beterminated at “Flood-Seal” connectors.
EPDM “FLOOD-SEAL” INSULATING SLEEVE COVERS ENTIRECONDUCTOR RANGE – Doubles as outlet cover until ready to useas insulating sleeve. Ordered separately.
READY FOR USE – Rugged 1/2" hardware provided. All outletsapproved for full cable rating.
PERFECT INSULATION INTEGRITY – Connectors are 100% factorydielectrically tested.
•
•
•
•
•
•
•
Commercial / IndustrialEPDM Rubber Insulated
ONE WAY
NUMBER OFOUTLETS
CATALOG NUMBER
“L”LENGTH
NUMBER OF OUTLETS
CATALOGNUMBER
TWO WAY
2345678
FS175-2FS175-3FS175-4FS175-5FS175-6FS175-7FS175-8
6"9"12"15"18"21"24"
46810121416
FS22-175FS33-175FS44-175FS55-175FS66-175FS77-175FS88-175
ALSO AVAILABLE IN COPPER, ADD SUFFIX “CU” TO CATALOG NUMBER.
FOR SPECIAL APPLICATIONS OR GREATER NUMBER OF OUTLETS
PLEASE CONSULT FACTORY.
ACCESSORIES
AL-NTN series aluminumlugs, 1/0 to 1000MCM,
are listed by Underwriter'sLaboratories, Inc.
See page 52
L-N series copper lugs,1/0 to 1000MCM, arelisted by Underwriter's
Laboratories, Inc.See page 58
“Flood-Seal” EPDM rubberinsulating sleeve covers the entire
conductor range. Order catalog #FS1175.
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
27
“Flood-Seal”® 125 Series One Hole and Two Hole NEMA Service Entrance Connectors
Cable range from #12 to 500 MCM aluminum or copper.
All outlets and lugs approved for full cable rating.
Maximum contact area assures cooler operating, more reliable joints.
Outlets equipped with 1/2" hex head bolts - with captive belleville washer.
One hole outlets accept standard AL-CU lugs. Two hole outlets acceptNEMA drilled lugs for residential and light commercial applications.
All “Flood-Seal” connectors comply with ANSI C119.4 specifications.
Connectors are 100% factory dielectrically tested.
•••••
••
ONE HOLE OUTLETCATALOG NUMBER
FS2-125
FS3-125
FS4-125
FS5-125
FS6-125
FS7-125
FS8-125
FS9-125
FS10-125
OUTLETS
2
3
4
5
6
7
8
9
10
L
3-1/2
5-3/8
7-1/4
9-1/8
11
12-7/8
14-3/4
16-5/8
18-1/2
TWO HOLE OUTLETCATALOG NUMBER
FSN2-125
FSN3-125
FSN4-125
FSN5-125
FSN6-125
FSN7-125
FSN8-125
FSN9-125
FSN10-125
ONE HOLE OUTLETCATALOG NUMBER
FSN-11
FSN-22
FSN-33
FSN-44
FSN-55
FSN-66
FSN-77
FSN-88
FSN-99
FSN-00
OUTLETS
2
4
6
8
10
12
14
16
18
20
L
1-1/2
3-3/8
5-1/4
7-1/8
8-7/8
10-3/4
12-5/8
14-1/2
16-3/8
18-1/4
TWO HOLE OUTLETCATALOG NUMBER
FS11-48
FS22-48
FS33-48
FS44-48
FS55-48
FS66-48
FS77-48
FS88-48
FS99-48
FS00-48
NOTE: All One Hole outletconnectors are supplied with EPDMrubber insulating sleeves.
Insulating sleeves are available for TwoHole outlet connectors - order catalognumber CSN2011.
Order lugs separately.
L
FS3-125
FSN6-125
LFS22-48
FSN-22
PVC Insulated
EPDM Rubber Insulated
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
28
“Flood-Seal”® 125 Series Service Entrance Connectors 1 & 2 Hole Type
Cable range from #8 to 500 MCM aluminum or copper.
All outlets and lugs approved for full cable rating.
Maximum contact area assures cooler operating,more reliable joints.
Outlets equipped with 1/2" hex bolts and captivebelleville washer.
EPDM Rubber InsulatedOne Way Configuration
PVC InsulatedTwo Way
Configuration
FS21-125L = 5-3/8"
FS31-125L = 7-1/4"
FS41-125L = 9-1/8"
FS111-125L = 5-3/8"
FS212-125L = 9-1/8"
FS313-125L = 12-7/8"
FS323-125L = 14-3/4"
FS222-125L = 11"
FS414-125L = 16-5/8"
Y TYPE
T TYPE X TYPE
FSY125-21
FST125
FSTT125
FSTT125N
FST125N
FSX125
FSXX125
FSX125N
FSXX125N
FSY125-21N FSY125-42N FSY125-64N
FSY125-64FSY125-42
Outlets accept standard AL-CU lugs, ordered separately.
All “Flood-Seal” connectors meet or exceed ANSI C119.4 requirements.
Rocket shaped EPDM sleeves are available to fully insulate all outlets.( for 1 hole outlets - order #CS 2011,for 2 hole outlets - order #CSN 2011).
Connectors are 100% factory di-electrically tested.
••
•
•
•••
•
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
29
“Flood-Seal”®
95 Series ServiceEntrance Connectors• Can be direct buried or installed in an enclosure.
• EPDM rubber insulating caps are supplied on all but one tap outlet.
• Single hole drilled for residential applications.
• Cable range from #12 to 350 MCM aluminum or copper.
• All outlets and lugs (see kits) approved for full cable rating.
• Maximum contact area assures cooler operating, more reliable joints.
• Kits are available with “Flood-Seal” insulating outlet sleeve (force fit)or heat shrink sleeve and appropriate lug.
• Connectors are 100% dielectrically tested.
CATALOGNUMBER
FS95-2FS95-3FS95-4
CATALOGNUMBER
FS95-5FS95-6FS95-7
CATALOGNUMBER
FS95-8FS95-9
FS95-10
OUTLETS
234
OUTLETS
567
L
2-3/4"4-1/4"5-3/4"
L
7-1/4"8-3/4"
10-1/4"
L
11-3/4"13-1/4"14-3/4"
OUTLETS
89
10
“FLOOD-SEAL” 95 CONNECTOR KITSCompressed with a common installation tool, three die sets install the complete range of lugsfrom #8 Str - 350 MCM Str. The lugs are prefilled with an oxide inhibiting compound and capped.
“FLOOD-SEAL” 95 CONNECTOR ONLY
FORCE FITKIT. NO.
HL10-38-CSCFG-8-CSCFG-6-CSCFG-4-CSCFG-2-CSCFG-1-CS
CFG-1/0-CSCFK-1/0-CSCFK-2/0-CSCFK-3/0-CSCFK-4/0-CSCFK-250-CSCFB-250-CSCFB-300-CSCFB-350-CS
HEAT SHRINKKIT. NO.
CFG-8-HSCFG-6-HSCFG-4-HSCFG-2-HSCFG-1-HS
CFG-1/0-HSCFK-1/0-HSCFK-2/0-HSCFK-3/0-HSCFK-4/0-HSCFK-250-HSCFB-250-HSCFB-300-HSCFB-350-HS
CONCENTRIC
86421
1/01/02/03/04/0250250300
336.4-350
COMPRESSED
-6421
1/01/02/03/04/0250250300350
COMPACT
-64
2 & 11/02/02/03/04/0250300300350350
SOLID
6--1
1/02/02/03/04/0-----
DIEREF.
5/8BG, 687
243TU, 52
8A
840324, 249
658TX, 76
11A1-1/8-1299-65596, 13A321, 326
#12 STR. THRU #8 SOLID COPPER
FORCE FIT KITKit consists of 1 center
formed lug, 1 EPDM rubberinsulating sleeve, button
head socket cap screw withbelleville washer,
installation instructions andtool recommendations.
HEAT SHRINK KITKit consists of 1 center
formed lug, 1 mastic linedheat shrink sleeve, button
head cap screw withbelleville washer,
installation instructions andtool recommendations.
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
30
Sweetheart Connectors are performance engineered to meet exactingfield requirements. All SHC series connectors feature time saving setscrew hex wrench installation. “Ball bottom” screws provide thewidest conductor range and aid in the break up aluminum oxides.
Sweetheart outlet configuration nests two equal sized servicecables from #6 to 2/0 or two unequal sized cables from #2 to2/0, saving outlet space and consequent cost. Unique, widerange (1/0-350 MCM), cable outlets permits use ofstreetlight wire either in original construction or as alater addition.
“Flood-Seal” EPDM insulating sleeves* double aswaterproof spare outlet caps until use aswaterproof cable insulators.
Surpasses requirements of ANSI C119.1,C119.4, and Western UndergroundCommittee Guidelines.
Doubles cable capacity!Halves space requirement!
space savingSweetheart
outlet
* “Flood-Seal” EPDMinsulating sleeves -
Field tested in over 10million applications.
Exclusive streetlightoption - 14 Sol.-#6
Wide range outlet - 1/0to 350 MCM
A - Sweetheartoutlet
B - outlet withS/L option
High strength, highconductivity
aluminum alloy
Sweetheart “Flood-Seal”® Mechanical ConnectorsCATALOG NUMBER GUIDE FOR SWEETHEART OUTLET:2 designates Sweetheart outlet, 1 designates Outlet with S/L option.
CABLE RANGE
SWEETHEART FEEDER OUTLETNUMBER CATALOG
LOUTLET FEEDER S/L
OUTLETS NUMBER
EQUAL #6 to 14SOL2
SHC-213-5/8CABLE 350 MCM SHC-22
TWO #6 to 2/0 (cable rangewhen using TO 3
SHC-1215-1/2
UNEQUAL S/L tap SHC-212
CABLE is 1/0 to #6 4 SHC-2112 7-3/8TWO #2 to 2/0 350 MCM) 5 SHC-21212 9-1/4
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
31
Single Screw Designs ALL OUTLETS SEALED WITH “FLOOD-SEAL” EPDM ROCKETSFlood-Seal”® Double 4/0
Mechanical Connector SeriesDOUBLES CABLE CAPACITY – HALVES SPACE REQUIREMENT.
“
Flood-Seal”® Mechanical 4/0 Connector Series“
Flood-Seal”® Mechanical 500 Connector Series“
SHC 500-240SLSHOWN
FOR FEEDEROUTLET WITH
SPECIAL PATENTEDSTREETLIGHT OPTION.
FORDOUBLE 4/0
OUTLETS
SHC 4/0-4SHOWN
SHC 500-4SHOWN
T.M.
CATALOG WIREOUTLETS NUMBER RANGE L H
2 SHC500-2 4-1/4"4 SHC500-4 #2 8-3/4" 3-3/8"6 SHC500-6 to 13-1/4"8 SHC500-8 500MCM 17-3/4"
CATALOG WIREOUTLETS NUMBER RANGE H
2 SHC 4/0-23 SHC 4/0-3 #124 SHC 4/0-4 to 2-1/2"5 SHC 4/0-5 4/06 SHC 4/0-68 SHC 4/0-8
REA APPROVED
S/L TAP14SOL-6
NUMBER CATALOGCABLE RANGE OUTLETS NUMBER L
#6 to 350MCM 3 SHC-3 5-1/2(cable range when 4 SHC-4 7-3/8
using S/L tap5 SHC-5 9-1/4is 1/0 to 350MCM)6 SHC-6 11-1/8
8 SHC-8 14-7/8
"Flood-Seal"Mechanical Connectorwith Streetlight option
* All outlets are provided with insulating rocket sleeves, with one sleeve having the streetlight capability.
*
CATALOG WIRE4/0 OUTLETS ONLY NUMBER RANGE L H
END VIEW OF OUTLETS. SHC 240 #4 2-5/16"
to 3-3/16"
SHC 440 4/0 4-5/8"
CATALOG WIRE4/0 WITH 500 MCM FEEDER NUMBER RANGE L H
END VIEW OF TAPOUTLETS. SHC 500-240SL #4 to 4-1/2"
4/0
FEEDERSHC 500-440SL #2 to 6-3/4" 4-1/8"
500MCM
S/LSHC 500-640SL #14 9-1/8"
to #4
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
32
Flood-Seal”® Twin ScrewSubmersible Connector• VERSATILE – Direct buried or above ground pedestal installation.
• RELIABLE – Twin screws double the reliability of ordinary set screw connectors.
• WATERTIGHT – Outlets sealed with “Flood Seal” EPDM rubber insulating sleeves.
• WIDE CABLE RANGE – Accepts copper or aluminum conductor from #6 to 350 MCM.
• BALL BOTTOM SET SCREWS – Accept 5/16" standard hex wrench.
“
ONE WAYCATALOG #
UH-2RUH-3RUH-4RUH-5RUH-6RUH-8R
CABLERANGE
#6TO350
MCM
TWO WAYCATALOG #
UH-22RUH-33RUH-44RUH-55RUH-66RUH-88R
LENGTH
3"4-3/4"6-1/2"8-1/4"
10"13-1/2"
OUTLETS
234568
OUTLETS
468101216
CATALOGNUMBER
UH750-2RUH750-3RUH750-4RUH750-5RUH750-6RUH750-8R
CABLERANGE
1/0to
750MCM
LENGTH
4-3/8"6-7/8"9-1/2"
12"14-5/8"19-3/4"
OUTLETS
234568
CATALOGNUMBER
UH750-22RUH750-33RUH750-44RUH750-55RUH750-66RUH750-88R
CABLERANGE
1/0to
750MCM
LENGTH
4-3/8"6-7/8"9-1/2"
12"14-5/8"19-3/4"
OUTLETS
468101216
ONE WAYOUTLETS
TWO WAYOUTLETS
Flood-Seal”® 750 SeriesTwin Screw Submersible Connector
“
WATERTIGHT - Outlets sealed with “Flood-Seal” EPDM rubber insulating sleeves.
WIDE CABLE RANGE - Accepts copper or aluminum conductor.
••
Flood-Seal”® Mechanical500 Connector Series
UH500-4RSHOWN
WIRE CATALOGRANGE NUMBER OUTLETS L H
UH500-2R 2 4-1/4"#2 UH500-4R 4 8-3/4" 4-3/4"to UH500-6R 6 13-1/4"
500MCM UH500-8R 8 17-3/4"
“
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
33
Twin Screw DesignsALL OUTLETS SEALED
WITH “FLOOD-SEAL”EPDM ROCKETS
New!“Flood-Seal”® Dual Outlet ConnectorsWith Patented Streetlight Port4/0 OUTLETS WITH 750MCM FEEDER
SEPARATE PORT AND SCREWFOR STREETLIGHT
UH750-440SLRSHOWN
FEEDER OUTLET HAS PATENTED SL PORTWITH ITS OWN SCREW.
350 OUTLETS WITH 750MCM FEEDER
m
Flood-Seal”® Mechanical1000 Connector Series
UH1000-4RSHOWN
“
WIRE CATALOGRANGE NUMBER OUTLETS L H
#12 - 4/0 2-4/0UH 750-240SLR 1-750 5-1/2"
FEEDER1/0 - 750MCM 4-4/0
5-1/2"UH 750-440SLR 1-750 8-1/2"S/L
#14 - #4 6-4/0UH 750-640SLR 1-750 11-1/2"
WIRE CATALOGRANGE NUMBER OUTLETS L H
#6 - 350MCM2-350
UH 750-235SLR 1-750 5-5/8"
FEEDER1/0 - 750MCM
4-350 6"UH 750-435SLR 1-750 9-3/8"
S/L#14 - #4
6-350UH 750-635SLR 1-750 13-1/8"
T.M.
WIRE CATALOGRANGE NUMBER OUTLETS L H
UH1000-2R 2 4-3/4"#2 UH1000-4R 4 9-7/8" 5-3/8"to UH1000-6R 6 15"
1000MCM UH1000-8R 8 20-1/8"
CATALOGNUMBER
UH750-4SLR
UH750-6SLR
CABLERANGE
1/0 to750MCM
S/L14 to #2
LENGTH
9-1/2"
14-5/8"
OUTLETS
4
6
750 Series Twin Screw Submersible Connectorwith Patented Streetlight Outlet
New!
Outlets sealed with“Flood-Seal” EPDMInsulating Sleeves
UH1000 SERIES ARE AVAILABLE IN TWO WAY CONFIGURATIONS, PLEASE CONSULT THE FACTORY.
FOR VARIATIONS OR SIZES OTHER THAN LISTED,PLEASE CONSULT THE FACTORY. The Homac Companies
12 Southland RoadOrmond Beach, FL 32174
Phone: 904/677-9110 Fax: 904/673-5497
34
“Flood-Seal”® Rubberized Aluminum BarFully insulated and watertight – suitable fordirect burial, handhole or pedestal application.
REA approved
RUGGED CONSTRUCTIONFabricated with 6061-T6 aluminum withmolded EPDM rubber insulation
EXCLUSIVE “RUBBERBUMPER” molded into backof the connector, guardsagainst handling damage
INDIVIDUALLY TESTEDfor insulation integrityand watertightness
WIDE RANGEwire range of #12 to 350 MCMor #12 to 500 MCM
This illustration shows a 350 MCM connector
EASY TO FOLLOW INSTRUCTIONSmolded into top of connector
BALL BOTTOM SCREW DESIGNbreaks up interstrand oxides
FLEXIBLE GRIP TABS allow easyaccess to set screws and
eliminate accidental removal
SIMPLE INSTALLATIONuses 5/16” hex wrench
CABLERANGE
#12 SOLTO
350 MCM
CABLERANGE
#12 SOLTO
500 MCM
OUTLETS
3
4
5
6
7
8
CATALOGNUMBER
RAB-3
RAB-4
RAB-5
RAB-6
RAB-7
RAB-8
CATALOGNUMBER
RAB 45
RAB 65
RAB 85
L
3-7/32
4-7/32
5-7/32
6-7/32
7-7/32
8-7/32
L
7
10-1/2
14
H
2-5/8
OUTLETS
4
6
8
H
2-5/8
��������������������������
RXL Series RubberizedAluminum Bar
Extra rugged construction - fabricated from 6061-T6 aluminum with molded EPDM rubber insulation.
Fully insulated and watertight - suitable for direct burial, handhole and pedestal applications.
Only 20 Ft. Lbs. of torque required for a perfect connection on largest wire size.
Wire range - #12 Sol. to 350 MCM.
Ball bottom screw design helps break up aluminum oxides.
•
•
•
••
More Hand Room!
OUTLETS468
CATALOG NO.RXL 4RXL 6RXL 8
LENGTH6-3/16"9-5/16"12-7/16"
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
35
OVERHEAD OR UNDERGROUND
• RUGGED CONSTRUCTION – fabricated from 6061-T6 aluminum with molded EPDMrubber insulation.
• FULLY INSULATED AND WATERTIGHT – suitable for direct burial, handhole/pedestal and overhead applications.
• WIDE CABLE RANGE – accommodates #2 Solidto 1000 MCM.
• EASY TO FOLLOW INSTRUCTIONS –molded into connector.
• BALL BOTTOM SCREW DESIGN – breaks up interstrand oxides.
• EPDM RUBBER CAP – designed to prevent accidental removal, can be easily removedwith pliers. Orange caps easy to find. Suffix “B”for black caps for overhead applications.
CABLE ENTRY FROM EITHER SIDE.EXAMPLE: RXM 22 ACCOMMODATES A MAXIMUM OF 4 CABLES, ACCESSIBLE FROM EITHER SIDE.
ORDER USING FIRST NUMBER (RXM 31) FOR OUTLETSNEEDED ON ONE SIDE AND SECOND NUMBER (RXM 31)FOR OUTLETS NEEDED ON OPPOSITE SIDE.
CONSULT FACTORY FOR CONFIGURATIONS UP TO ATOTAL OF 12 OUTLETS.
CABLES ENTER FROMONE SIDE ONLY.
Flood-Seal”®
RXM SeriesRubberizedAluminum Bar
“
CAT. NO. OUTLETS LENGTH
RXM 2 2 3-1/16
RXM 4 4 7-1/4
RXM 6 6 10-7/8
RXM 8 8 14-1/2
RXM 10 10 18-1/8
RXM 12 12 21-3/4
CAT. NO. OUTLETS LENGTH
RXM 22 4 7-1/4
RXM 44 8 14-1/2
RXM 66 12 21-3/4
CAT. NO. OUTLETS LENGTH
RXM 31 4 7-1/4
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
__________________________________
__________________________________
__________________________________
__________________________________
__________________________________
__________________________________
__________________________________
__________________________________
__________________________________
__________________________________
Reliable watertight underground
splices for #2 to 4/0 cable.
Installs connectors up to 4/0 cable
in only 10” space using
Homac’s New UT3-M tool or
UT3 tool with gold die.
Now new sizes up to 500 MCM.
Passes ANSI C119.4
36
PATENTED
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
37
RRK SeriesRADIATING RIB Splice System“Flood-Seal”® EPDM Insulated
TM
QUICK, UNDERGROUND SPLICE FOR SECONDARY AND SERVICECABLE - Radiating Rib Connector allows use of Homac’s New UT3-M tool orthe UT3 tool with gold die for wire sizes up to 4/0.
EASY / LABOR SAVING - only 10" wide trench required - especiallyconvenient for making repairs.
HEAT DISSIPATING RADIATING RIB centers watertight insulating cover,and seals perfectly every time.
PROVEN EPDM RUBBER “FLOOD-SEAL” INSULATING COVER fits snuglyfor maximum heat dissipation.
FULLY TESTED - meets requirements of ANSI C119.4.
•
•
•
•
•
SPLICE KITCAT. NUMBER
RRK 2
RRK 1
RRK 10
RRK 20
RRK 30
RRK 40
RRK 250
RRK300
RRK 350
RRK 500
WIRE RANGECOMPRESSED
#2
#1
1/0
2/0
3/0
4/0
250
300
350
500
CONNECTORLENGTH
3"
4-1/4"
4-1/2"
6-3/4"
INSULATORLENGTH
5-1/2"
7-1/4"
7-1/2"
10-3/4"
INSTALLINGDIES
5/8"
840, TX, 76249, 11A
115H, 1-5/16473, 786
STRANDED
#2
#1
1/0
2/0
3/0
4/0
250
300
350
500
COMPACT
#2
#1
1/0
2/0
3/0
4/0
250
300
350
500
FOR REDUCERS AND SIZES NOT LISTED, PLEASE CONSULT THE FACTORY.
Un
derg
rou
nd
Sp
licing
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
Homac Direct Buried “Flood-Seal” service Clusters provide an economical means of makingtap connections from a secondary main. Compact, for direct burial, the cost of pedestals andhand holes is eliminated.
Over 100,000 Homac Direct Buried ServiceClusters are in service, with excellent fieldexperience. Thoroughly tested to assurereliable submersible service.
Cable leads factory installed.
EPDM housing components, factory press fitted, provide watertight security.
Cable ends sealed with EPDM “Flood-Seal” Cable Caps.
Wide range of service cables accommodated through the use of standard reducer-enlarger splices.
“Flood-Seal” Submersible Splice Kits are available for all cable combinations.
As many as 8 service taps available through use of Twin Tap Kits (pg. UD-25).
••••
••
38
“Flood-Seal”® Submersible Splice Covers
“Flood-Seal”® Direct Buried Service Clusters
Four basic sizes cover a conductor range from #14stranded to 1500 MCM.
Indefinitely maintains WATERTIGHT integrity and fullinsulating value in all direct buried, undergroundnetwork, residential and overhead service splice joints.
Taping is eliminated, LABOR and MATERIAL COST ofsplice preparation is significantly REDUCED.
Rated 600 volts.
•
•
•
•➀➀ COPPER
CONDUCTORRANGE
14-2/0
14-350
14-350
14-500
14-500
2-1000
2-1000
2-1500
➁➁ ALUMINUMCONDUCTOR
RANGE
14-2/0
14-350
14-350
14-500 ➂➂14-500
2-750
2-1000
2-1000
CATALOGNUMBER
FSS20
FSS350
FSS350L
FSS500
FSS500L
FSS1000S
FSS1000
FSS1000L
CABLEINSULATION
DIAMETER RANGE
.150-.600
.150-.980
.150-.980
.150-1.175
.150-1.175
.370-1.600
.370-1.600
.370-1.600
L
2-1/4"
4-7/16"
7-1/2"
4-7/16"
7-5/8"
5"
10"
18-1/8"
E50999THESE COVERS WHEN USED WITH HOMAC CONNECTORS C,SC AND ASC TYPES ARE UL LISTED INSULATED COVER CABLECONNECTORS IN ACCORDANCE WITH UL486A AND UL486B.
E121862LISTED “WIRE CONNECTOR SYSTEM FORUSE WITH UNDERGROUND CONDUCTORS”.
RECOMMENDED IN-LINE SPLICES.
➀➀ COPPER CONNECTORS see page(s).....
➁➁ ALUMINUM CONNECTORS see page(s)..
➂➂ FOR 500 MCM ALUMINUM, REMOVELINER FROM CAP.
Homac’s versatile “Flood-Seal” splice cover is also readily adaptable as a half-ready splice, insulated pin terminal or cable cap.
REA approved
ASECONDARY
4/0
350
CATALOGNUMBER
CL4
CL7
BSERVICES
1/0
1/0
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
39
Flood-Seal”®
Twin Tap Covers Indefinitely maintain their watertight integrity andfull insulating value in all direct buried applications.
Save time and money – taping is eliminated, laborand material cost is significantly reduced.
Features a broad cable range from streetlight toservice sizes.
Three Wire Covers
Four Wire Covers
CATALOGNUMBER
FSS 4040
FSS5035
CATALOGNUMBER
FSS 1010-4
FSS 4020-4
FSS 5035-4
A
#14-500 MCM
#2-1000 MCM
A
#14 - 1/0
#14 - 250
#14 - 500
B
#14 - 1/0
#14 - 1/0
#14 - 400
CABLE RANGE
B
#14-250 MCM
#14-500 MCM
C
#14-250 MCM
#14-400 MCM
•
•
•
CABLE RANGE
Continuing Main - One Tap,with room for a future tap.
Terminated Main, Two tapswith a possible continuing
main in future.
Continuing Main withTwo Taps
VARIOUS APPLICATIONS
VARIOUS APPLICATIONS
“
To install, just cut the proper cable rings at each end ofthe “Flood-Seal” Twin Tap cover and slide cover halvesover cables. The cover halves are then mated, enclosingthe compression tap in a waterproof insulated seal.
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
40
“Flood-Seal”® Mechanical Underground Cable Repair Splice
Direct Burial Set ScrewBar Connectors
Compression Type Repair Kit
Fast, easy cable repair - no special tools are needed to install our high conductivity aluminum, mechanical splice - just a 5/16 hex wrench.
No taping, heat shrink or mastic - “Flood-Seal” EPDM rubber splice covers insure a fully insulated, watertight repair splice.
Two splice lengths, 12" or 18", eliminate the need to add a length of cableand make two splices.
Repairs cable sizes from #6 STR to 350 MCM.
12" Repair splice - Order catalog # USK350-1218" Repair splice - Order catalog # USK350-18
Accepts cable sizes from #2 STR to 350 MCM with standard one hole lugs (see catalog page ...........for recommended lugs).
Assembly includes - 350 MCM XLPE aluminum stranded cable installedwith 350MCM lugs, 1/2" hex bolts with captive belleville washers andinsulated with “Flood-Seal” splice covers at each end.
For field assembly - fit cable to be joined with one hole, 1/2" bolt hole lugs. Bolt lugs together, then tighten and assemble splice covers.
2 Wire Kits
3 Wire Kit
4 Wire Kits
WIDE WIRE RANGE - #6 to 750 MCM.
600 VOLT RATED WATERTIGHT INSULATION PROVIDED - “Flood-Seal” EPDM covers are proven in over 20 million field applications.
MAXIMUM CONDUCTOR CONTACT PRESSURE - range taking “ball bottom” screws.
ALL HOMAC BAR CONNECTORS FULLY TESTED - meet or exceedrequirements of ANSI C119.4.
CABLERANGE
#6 TO350 MCM
#6 TO350 MCM
#2 TO500 MCM250 TO
750 MCM† #6 TO
350 MCM†† #6 TO350 MCM
#6 TO350 MCM
FIG.
A
B
C
D
E
FG
CONNECTORLENGTH
4-1/16"6-1/2"
2-9/16"
4-3/16"7-1/2"
6-1/16"
2-9/16"
3-7/8"
4-1/8"2-5/8"
CATALOGNUMBER
UH11UH11L
USK350
USK500USK500L
USK750
USK4/0-SL
UH11SL
* MTB350* MTB350-1
CONNECTOROUTLETS
2
2
2
2
2
4
# OF SCREWS/ CONDUCTOR
2
1
2
1
2
21
A
B
C
D
E
* G* F
•
•
•
•
•
•
•
••
•
•
Order catalog # URS125
500 MCM kit available, please consult the factory.
† Cable range for outlets with a S/L tap is 1/0 to 4/0. S/L range is 14 SOL to #6.
†† Cable range for outlets with a S/L tap is 1/0 to 350 MCM. S/L range is 14 SOL to #6.
For Tin Plating, add suffix ‘TN’ to catalog number.
Specially designed for terminating four conductors;three taps to a terminated secondary or two taps to a continuing secondary.
*
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
41
“Flood-Seal”® In-Line Splice Kits• Conveniently packaged in aplastic bag, kits contain onesubmersible splice cover andthe appropriate copper oraluminum connector.
• Each splice is approved forAL-CU connections and areprefilled with oxide inhibitorand capped.**
• To insure equal cable insertion, connectors have acenter cable stop.
• Upon request, kits are available with splice coversopen ended and ready to use. Please consult the factoryfor this option.
WIRE SIZE
6
4
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
750
1000
COPPER CONDUCTOR
CAT. NO.
ULCK-6
ULCK-4
ULCK-2
ULCK-1
ULCK-1/0
ULCK-2/0
ULCK-3//0
ULCK-4/0
ULCK-250
ULCK-300
ULCK-350
ULCK-400
ULCK-500
ULCK-600
ULCK-750
ULCK-1000
**ALUM.CONDUCTOR
CAT. NO.
ULSK-6
ULSK-4
ULSK-2
ULSK-1
ULSK-1/0
ULSK-2/0
ULSK-3/0
ULSK-4/0
ULSK-250
ULSK-300
ULSK-350
ULSK-400
ULSK-500
ULSK-600
ULSK-750
ULSK-1000
SPLICE COVER
FSS20
FSS350
FSS500L
FSS1000
SPLICE COVER
FSS20
FSS350
FSS500L
FSS1000
“Flood-Seal”® Submersible Splice Kits
THESE COVERS WHEN USED WITH HOMAC CONNECTORS C,SC AND ASC TYPES ARE UL LISTED INSULATED COVER CABLECONNECTORS IN ACCORDANCE WITH UL486A AND UL486B.
FOR SPLICE SIZES NOT SHOWN, PLEASE CONSULT THE FACTORY.
REDUCING KITS ARE AVAILABLE, PLEASE CONSULT THE FACTORY.
FOR SPLICE SIZES NOT SHOWN, PLEASE CONSULT THE FACTORY.
Conveniently packaged in a plastic bag, kits contain one submersiblesplice cover and one aluminum compression splice.
Each splice is approved for AL-CU connections and are prefilled withoxide inhibitor and capped.
Can be ordered with either straight or reducing splices.
Upon request, kits are available with copper splices, or with splicecovers open ended and ready for use. Consult factory.
CONNECTOR WIRE SIZE CONNECTOR WIRE SIZESPLICE KITCATALOG NO.
FSK4
FSK2
FSK1
FSK1/0
FSK1/0R2
FSK2/0R1/0
FSK2/0
FSK4/0R2/0
FSK3/0
FSK4/0
FSK250
FSK300
SPLICE KITCATALOG NO.
FSK350R4/0
FSK350
FSK400
FSK500R4/0
FSK500R350
FSK500
FSK600
FSK750
FSK750R500
FSK1000R500
FSK1000R750
FSK1000
SPLICECOVER
FSS20
FSS350
SPLICECOVER
FSS500
FSS1000
FROM
4
2
1
1/0
1/0
2/0
2/0
4/0
3/0
4/0
250
300
FROM
350
350
400
500
500
500
600
750
750
1000
1000
1000
TO
4
2
1
1/0
2
1/0
2/0
2/0
3/0
4/0
250
300
TO
4/0
350
400
4/0
350
500
600
750
500
500
750
1000
•
•
••
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
42
Twin Tap Kits “Flood-Seal” Twin Tap assemblies provide a reliable,economical means of making direct buried tap connections to URD secondaries. Eachkit includes a watertight submersible EPDM tap cover and a range taking H typeconnector. Connectors are installed with popular 'O', 'D', and 'N' dies in Homac andcompetitive compression tools.
Twin Tap kits are available for applications where one or two taps are required from acontinuing main and where two taps are required for terminal main. Both wiringpractices reduce cable usage and overall URD costs by allowing tap connections to bemade in closest proximity to service loads.
H type connectors exceed ANSI C119.4 requirements. Twin Tap covers are thoroughly tested for submersible application.
“Flood-Seal”® Twin TowerOutlet Sleeves
Save money and space, reduce by up to half the numberof outlets on every bus bar - double terminations onexisting “Flood-Seal” buses.
Allows a streetlighting tap and service conductor to bemade off the same outlet.
Closed end cable sealing towers allow installation of onetap now, another later.
Cover spare outlets with Twin Tower Outlet Sleeves,double future tap capacity.
To install, just cut the proper cable rings of the “Flood-Seal” Twin Tap cover and slide cover halves over cables.
CONCENTRIC
1 - 62/0 - 22/0 - 4
4/0 - 3/0
500 - 250
CONCENTRIC
1 - 61 - 6
2/0 - 42 - 6
2/0 - 24/0 - 3/02/0 - 6
4/0 - 2/0350 - 250
COMPACT
1 - 62/0 - 23/0 - 4
250 - 3/0
500 - 250
COMPACT
1 - 61/0 - 63/0 - 41 - 6
3/0 - 1250 - 3/02/0 - 6
4/0 - 2/0350 -250
COMPRESSED
1 - 61 - 6
2/0 - 42 - 6
2/0 - 1250 - 3/02/0 - 6
4/0 - 2/0350 -250
DIE
O
D
N
COMPRESSED
1 - 62/0 - 22/0 - 4
250 - 3/0
500 - 250
C.M. KITONE TAP
H011H015H017HD22HD24HD30HN38HN32HN36
C.M. KITTWO TAPS
GHO51GHO52GHO53GHD54GHD55GHD56GHN57GHN58GHN59
T.M. KITTWO TAPS
H011H013H017HD26HD28HD30HN34HN40HN36
GROOVE A - STRANDED CABLE
CONTINUING MAIN (C.M.KIT)ONE TAP OR TWO TAPS
TERMINATED MAIN (T.M.KIT) TWO TAPS
GROOVE B - STRANDED CABLE
CATALOG NUMBER
CST 3095For use on “Flood-Seal”125 Series connectors
CST 3136For use on “Flood-Seal”DF, DH and 175 Series
connectors
B
14 - 250 MCM
14 - 500 MCM
C
14 - 250 MCM
14 - 400 MCM
CABLE RANGE
•
•
•
•
•
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
43
CATALOGNUMBER
CAP35CAP45CAP55CAP65CAP85*CAP95*CAP105*CAP125*CAP130*CAP135*CAP145*CAP150*CAP155
H3/4”7/8”1”
1-1/4”1-3/8”1-7/8”2-1/8”2-3/8”2-1/2”2-5/8”2-7/8”
3”3”
MIN..250.360.455.575.720.9701.1201.2001.3901.4651.6501.8602.150
MAX..425.562.626.750.9731.1851.4001.4751.6501.7501.9252.2302.500
MIN.6.49.111.614.618.324.628.430.535.337.241.947.254.6
MAX.10.814.315.919.024.730.135.637.541.944.549.056.663.5
MIN.621
2/0250500750750
1233.71500
1973.5
MAX.2
1/03/0250400700
100010001250
1578.82000
MIN.621
3/0350500750750
---
MAX.2
1/03/0300400750
10001000
---
MIN.621
3/0250600800800
---
MAX.2
2/03/0300400800
10001000
---
DECIMAL RANGE MM CONCENTRIC COMPRESSED COMPACT
660V. CABLE APPLICATION
FITS HIGH VOLTAGE CABLE ONLY
“Flood-Seal”® Cable End Caps
CABLE CAP CONDUCTOR RANGES SHOWN ARE FOR OUTER O.D. OVER CABLE INSULATION
*INDICATES CAP WITH INTERNAL PROTECTIVE BUTTON HIGH VOLTAGE CABLE CAP APPLICATION:Caps 45 and larger also protects high voltagecable against moisture intrusion. Select diameterto be sealed — outer jacket, semi-con shield orinsulation. Then, refer to the diameter rangesshown above to determine appropriate cable cap.
FOR CABLE SIZES NOT LISTED, PLEASE CONSULT THE FACTORY
Range taking through the resilienceof EPDM rubber and multiple internal sealing ring design.
Reusable for greatest economy.
Durable, unaffected by sun, rain or soil.
Tight fitting, to avoid accidental removal.
Watertight without the use of heat,tape or cement.
Dielectrically tested to ANSI specification C119.1 (2,200 volts AC for one minute).
Internal protective button permits pocketing of ragged concentric neutral wires, cap sizes 95 to 155.
���� ����•
••••
•
•
"Flo
od
-Seal" P
rod
ucts
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
44
Flood-Seal”®
Pipe/ConduitSealersPrecision molded in “Flood-Seal” EPDM rubber.
Unaffected by sun, rain or soil.
Seals out water, insects, rodents and dirt.
3/4"1/2"1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
5"
6"
101045566
4
4
4
5572241
7
216
9
7
9
8
431
9
6
7
216
7
7
CIC 75-3CIC 50-3CIC 1-4CIC 125CIC 150
CIC 15-320CIC 15-420
C-5230
C-5035
C-5231
CIC 200CIC 201
PS 23133
3133-6CIC 25-440CAP 250
PS 25
3135CAP 300CVC 3
CNC 3-1G
PS3
PSX 3
PSX 35
31386318
CAP 400
CNC 4-1G
CVC 4
PS 4
CIC 401CAP 500CVC 5
PS 5
PS 6
3341134
3
2
4
1131140
3
103
2
4
4
4
610
2
3
4
103
4
4
#14-10#14-10
(4)#14-4--
(3)#2-2/0(4)#2-2/0
(2)#14-350(1)#14-1/0(1)#14-400(1)#14-500(3)#14-350(1)#14-4/0
--
(3)#14-250300-1500300-1500(4)#2-4/0
NA(2)#14-350(1)#14-250350-2000
NA---
(3)#14-350(1)#14-250(3)#14-350(1)#14-250(3)#14-500
(1)#14-250 & 350-500
#14-400-
NA---
(3)#14-500(1)#14-350
-NA-
(3)#2-1500(1)#14-500(4)#2-1500
--
SL-.380.625-1.030.720-1.200.370-.580.370-.580SL-.910SL-.540SL-.980SL-1.175SL-.980SL-.690
1.093-1.562.937-1.145
SL-.765.760-1.880.760-1.880.390-.690
NASL-.980SL-.765
.830-2.234NA
(3)1.093-1.562(1)1.031-1.531(1).280-.420
SL-.980SL-.765SL-.980SL-.765SL-1.175SL-.765SL-.980
1.500-3.00NA
(1)1.031-1.531(1).280-.420
(3)1.125-1.875SL-1.175SL-.980
.830-2.234NA
1.250-2.00.370-1.600SL-1.175
.370-1.600
1-1/21-3/8
2-13/321-1/4
1-3/8
1-1/2
1-15/16
2
41-3/162-1/86-1/82-1/4
3
1-3/16
2-1/2
2-11/16
2-1/2
1-3/16
2-1/2
3-15/16
2
2-11/16
2-5/8
3-3/16
1-3/4
3-1/82-15/163-7/16
2-1/8
2-3/4
PIPESIZE(IPS)
STYLE
CATALOGNUMBER
#OF
OUT-LETS
CONDUCTOR RANGE
NOMINAL
OUTSIDEBODY
LENGTH(INCHES)
Can be easily removed for later serviceinstallations or cable replacements.
Choose from a wide variety of internaland external seals. Internal seals aredesigned for Schedule 40 pipe.
Tight fitting to avoidaccidental removal.
For sizes not listed, please consult the factory.
•••
•
•
•
•
“
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
45
Concentric Neutral Splice Kit forJacketed, High Voltage URD Type Cable
Homac’s CNC Neutral Splice Kit provides a complete submersible system to protect the neutral wiresfrom corrosion when splicing high voltage cable. The EPDM housing offers the following features:
•
•
•
Offers a separate sealing tower for connectionof a highly corrosive resistant drain wire fromneutrals to grounding tab(s) of pre-moldedH.V. splices.
Universal design - can be used with any pre-molded or taped splice.
•
•
(view of finished assembly)1 23
SNC-1
SNC-3
2-3/4" 7-3/4"
3-7/8" 12"
EACH KIT CONTAINS:
CAPS24” SPECIAL ALLOY DRAIN WIRESCOVERS
• SILICONE GREASE• (OPTIONAL) COPPER CONNECTORS
HOW TO ORDER:Measure the cable diameters of the outer jacket and theextruded insulation shield. Select the kit that accommodatesBOTH these dimensions.
600 VOLT INSULATED COPPER JUMPER CABLE (#6 TO2/0) IS REQUIRED BUT NOT SUPPLIED WITH THIS KIT.
FOR JOINING CABLE SIZES NOT ACCOMMODATED BY THE ABOVEKITS - CONSULT FACTORY.
FOR KIT CONTAINING COPPER MECHANICAL CONNECTOR FORNEUTRAL-JUMPER CONNECTION, ADD THE FOLLOWING SUFFIX:
SUFFIX '2' FOR JUMPER WIRE SIZES #6 - #2 (SNC-1-2)SUFFIX '20' FOR JUMPER WIRE SIZES #2 - 2/0 (SNC-3-20)
123
CONDUCTOR
INSULATION
EXTRUDED SHIELD
NEUTRAL WIRES
OUTER JACKET
DIA.”A”DIA.”B”
“Flood-Seal” integrity on the extruded semi-conducting shield and outer cable jacket.
Provides a waterproof chamber to connect theneutral wires to a suitable jumper cable.
No heat, tape or sealing compound required.
JACKET SHIELD CATALOGDIA. “A” DIA. “B” NUMBER
.760 - 1.500 .700 - 1.250 SNC-1
1.125 - 1.900 .925 - 1.550 SNC-3
FOR FUTURE SIZES
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
46
EACH KIT CONTAINS:CAP24" SPECIAL DRAIN WIRECOVER12" LENGTH(S) #2 SOLID COPPER WIRE* FORNEUTRAL-GROUND CONNECTION
• SILICONE GREASE• (OPTIONAL) COPPER CONDUCTOR
Concentric Neutral Termination Kit forJacketed, High Voltage URD Type Cable
Homac’s CNC Neutral Termination Kit provides a complete submersiblesystem to protect the neutral wires from corrosion when terminating highvoltage cable at an elbow or outdoor termination. The EPDM housingoffers the following features.
“Flood-Seal” integrity on the extruded semi-conducting shield and outer cable jacket.
Provides a waterproof chamber to connect neutral wires to a solid copper wire for connection to the system ground.
Offers a separate sealing tower for connection of a highly corrosive resistant drain wire from neutrals to grounding tab of pre-molded device.
No heat, tape or sealing compound required.
Universal design can be used with any pre-molded or taped termination.
•
•
•
••
1234
TNC-1M
2-3/4"
7-3/4"
21
3
4
TNC-3
12"
3-7/8"
21
3
4
SAMPLETERMINATIONS
Measure the cable diameters of the outerjacket and the extruded insulation shield.Select the kit that accommodates BOTHthese diameters.
FOR JOINING CABLE SIZES NOT ACCOMMODATED BY THE ABOVE KITS, CONSULT FACTORY.
FOR KIT CONTAINING COPPER MECHANICAL CONNECTOR FOR NEUTRAL-GROUND CONNECTION, ADD THE FOLLOWING SUFFIXES:
SUFFIX '2' FOR GROUND WIRE SIZES #6 - #2 (TNC-1M-2)SUFFIX '20' FOR GROUND WIRE SIZES #2 - 2/0 (TNC-3-20)
* WHEN USING THIS KIT TO TERMINATE THE CONCENTRIC NEUTRAL CONDUCTORS FOR AN ELBOW THAT MAY BESUBJECT TO SUBMERSION, THE GROUNDING LEAD MUST BE A SOLID COPPER BARE WIRE. IF A JACKETED SOLID ORSTRANDED WIRE IS USED, WATER CAN MIGRATE UP THROUGH THIS CABLE AND ENTER INTO THE TERMINATION KIT.
HOW TO ORDER
CONDUCTOR
INSULATION
EXTRUDED SHIELD
NEUTRAL WIRES
OUTER JACKET
DIA.”A”DIA.”B”
JACKET SHIELD CATALOGDIA.”A” DIA.”B” NUMBER
.760-1.500 .700-1.250 TNC-1M1.125-1.900 .925-1.550 TNC-3
FOR FUTURE SIZES
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
COMPRESSION IN-LINE NONFUSED KITS 600 VOLTALUMINUM IN-LINE DISCONNECT KIT consists of “Flood-Seal” housing, connecting link,fuse clips, silicone lubricant and instruction sheet.
WIRE SIZE (ALUM.) CAT. NO. INSTALLATION TOOLSTR SOLID
#14-10 #12-8 SDK-2A T&B WT111M, C DIE OR EQUAL#8-6 #6-4 SDK-3A T&B TBM-20S, BLUE DIE OR EQUAL
#14-10 #12-8 *SDT-2A T&B WT111M, C DIE OR EQUAL#8-6 #6-4 *SDT-3A T&B TBM-20S, BLUE DIE OR EQUAL
*TWIN HOUSING
COPPER IN-LINE DISCONNECT KIT consists of “Flood-Seal” housing, connecting link,fuse clips, silicone lubricant and instruction sheet.
SINGLE HOUSING TWIN HOUSING CU WIRE SIZEINSTALLATION TOOL
CAT. NO. CAT. NO. STR. SOL.
SDK-6 SDT-6#14-10 #14-8 T&B WT 111M, C DIE OR EQUAL#8-6 #6-4 T&B TBM-20S, BLUE DIE OR EQUAL
SDK-2 SDT-2#4 #2 T&B TBM-20S, GRAY DIE OR EQUAL#2 – T&B TBM-20S, BROWN DIE OR EQUAL
ALSO AVAILABLE IN 60 AMP, ADD - 60 SUFFIX (e.g., SDK-6-60)
NOTE: ALUMINUM FUSE CLIPS CAN BE USED ON COPPER OR ALUMINUM CONDUCTOR.
COMPRESSION IN-LINE FUSE KITS 600 VOLT 30 AMP MAX.ALUMINUM IN-LINE FUSE KIT consists of “Flood-Seal” housing, fuse clips,silicone lubricant and instruction sheet. FUSE NOT INCLUDED.
WIRE SIZE (ALUM.) CAT. NO. INSTALLATION TOOLSTR SOLID
#14-10 #12-8 SLK-2A T&B WT111M, C DIE OR EQUAL#8-6 #6-4 SLK-3A T&B TBM-20S, BLUE DIE OR EQUAL
#14-10 #12-8 *SLT-2A T&B WT111M, C DIE OR EQUAL#8-6 #6-4 *SLT-3A T&B TBM-20S, BLUE DIE OR EQUAL
*TWIN HOUSING
COPPER IN-LINE FUSE KIT consists of “Flood-Seal” housing, fuse clips,silicone lubricant and instruction sheet. FUSE NOT INCLUDED.
SINGLE HOUSING TWIN HOUSING CU WIRE SIZEINSTALLATION TOOL
CAT. NO. CAT. NO. STR. SOL.
SLK-6 SLT-6#14-10 #14-8 T&B WT 111M, C DIE OR EQUAL#8-6 #6-4 T&B TBM-20S, BLUE DIE OR EQUAL
SLK-2 SLT-2#4 #2 T&B TBM-20S, GRAY DIE OR EQUAL#2 – T&B TBM-20S, BROWN DIE OR EQUAL
ALSO AVAILABLE IN 60 AMP, ADD - 60 SUFFIX (e.g., SLK-6-60)
MECHANICAL FUSED & NONFUSED KITSWIRE SIZE (BOTH CU & AL) IN-LINE 600 VOLT 30 AMP MAX.
STRANDED SOLID CAT. NO.SLK-M FUSED*SLT-M
#10, 8, 6, 4 #12, 10, 8, 6, 4SDK-M NON-*SDT-M FUSED
*TWIN HOUSINGALSO AVAILABLE IN 60 AMP, ADD - 60 SUFFIX (e.g., SLK-M-60)
47
SINGLE HOUSING
SLK SeriesSDK Series
SLK-M & SDK-M
TWIN HOUSING
FOR 2 LIGHTING FIXTURESON ONE STANDARD
SLT SeriesSDT Series
SLT-M & SDT-M
Accepts Standard CartridgeFuse, 13/32" Diameter,
1-1/2" Length.(Non Glass Type)
“Flood-Seal”® In-Line Disconnect KitsWatertight and submersible.
Insulated with “Flood-Seal” EPDMrubber housing.
Breakaway design - kit separatesunder tension so wires won't break.
Safe - fuse or connecting link staysin Load side when separated.
Wide range - accepts wire sizes#14-6 AWG and#4 Solid (consultthe factory for larger wire sizes).
Fits insulated wires up to .38inches in diameter.
••
•
•
•
•
Streetlig
htin
g K
its
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
WIRE SIZE - CUSTRANDED
86421
1/02/0
CAT. NO.FYC-8FYC-6FYC-4FYC-2FYC-1
FYC-1/0FYC-2/0
INSTALLING DIES1/4, 6, TC, 21J, 7, TE, 24
5/16, 8, TP, 293/8, 10, TL-TN, 33
3/8, 11K TB, 371/2, 12, TQ, 429/16, 13, TS, 45
WIRE SIZE - CUSTRANDED
86421
1/02/0
CAT. NO.DYC-8DYC-6DYC-4DYC-2DYC-1
DYC-1/0DYC-2/0
INSTALLING DIES1/4, 6, TC, 21
J, TE, 245/16, 8, TP, 29
3/8, 10, TL-TN, 333/8, 11K TB, 371/2, 12, TQ, 429/16, 13, TS, 45
48
RUN
14-4 CUOR
14-2 AL
Y-TYPE
FUSE
NONFUSED
AL or CU RUN
14-2
14-2
CU TAP
14-64-214-64-2
CATALOGNUMBER
FYU-6FYU-2DYU-6DYU-2
WIRE SIZETAP
12-4 CU/AL
CATALOGNUMBER
FYU-M
DYU-M
Y-TYPE
FUSED
NONFUSED
MECHANICAL Y-TYPE KITS 600 VOLT
MECHANICAL RUN / COMPRESSION TAP
Y-TYPE FUSE KITS (COMPRESSION) 600 VOLT 30 AMP MAX.
Y-TYPE NONFUSED KITS (COMPRESSION) 600 VOLT
MECHANICAL CONNECTOR INSTALLED WITH 1/8" HEXWRENCH. FUSE NOT INCLUDED IN KIT.
WIRE SIZE - ALSTRANDED
642
1/02/0
CAT. NO.FYA-6FYA-4FYA-2
FYA-1/0FYA-2/0
INSTALLING DIES
52, BG, 243, 5/8
58, 297, 245, 5/8-1
WIRE SIZE - ALSTRANDED
642
1/02/0
CAT. NO.DYA-6DYA-4DYA-2
DYA-1/0DYA-2/0
INSTALLING DIES
52, BG, 243, 5/8
58, 297, 245, 5/8-1
* If fixture or tap wire is aluminum, add one of the following suffixes:-2A for #14-10 STR or #12-8 SOLID (ie. FYC-1/0-2A)-3A for #8-6 STR or #6-4 SOLID (ie. FYA-1/0-3A)
FOR ALUMINUM RUN WITH COPPER TAP*ALUMINUM Y-TYPE FUSE KIT consists of“Flood-Seal” housing, fuse clips,2 aluminum lugs, hardware,silicone lubricant and instruction sheet.FUSE NOT INCLUDED.
FOR ALUMINUM RUN WITH COPPER TAP*ALUMINUM Y-TYPE DISCONNECT KITconsists of “Flood-Seal” housing, fuse clips,connecting link, 2 aluminum lugs, hardware,silicone lubricant and instruction sheet.
FOR COPPER RUN WITH COPPER TAP*
COPPER Y-TYPE FUSE KIT consists of“Flood-Seal” housing, fuse clips,2 copper lugs, hardware,silicone lubricant and instruction sheet.FUSE NOT INCLUDED.
FOR COPPER RUN WITH COPPER TAP*
COPPER Y-TYPE DISCONNECT KITconsists of “Flood-Seal” housing, fuse clips,connecting link, 2 copper lugs, hardware,silicone lubricant and instruction sheet.
Watertight and submersible.
Re-enterable for sectionalizing.
Insulated with “Flood-Seal” EPDM rubber housing.
Breakaway design - kit separates under tension so wires won't break.
Safe - fuse or connecting link stays in Load side when separated.
Tap accepts wire sizes #6-14 AWG and#4 Sol. (.38 in. max. insulation diameter).
Run or feeder lugs have same ampacityrating as the cable, up to 2/0.
Run side accepts insulated wires up to.78 inches diameter.
•••
•
•
•
•
•
Flood-Seal”® Y-Type Disconnect Kits“
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
49
“Flood-Seal”® YY-Type
Fused and NonfusedYY Fused connector kits are for use when surge arrestor protectionis installed in a lighting standard. YY Nonfused connector kits areused for grounding the neutral at each lighting standard.
Insulated with “Flood-Seal” EPDM rubber housing - 600 Volt Rated.
Breakaway design - kit separates under tension to prevent conductorsfrom breaking.
SAFE: Fuse or connecting link always stays in load side when separated.
Kits are re-enterable for sectionalizing.
Watertight and submersible.
Unaffected by exposure to sunlight.
••••••LOAD SIDE (all kits)
Utilizes a tin plated mechanical connector for copper or aluminum conductors #14 to #6 AWG.
TO ORDER WITH MECHANICAL CONNECTOR ON LINE SIDE:
TO ORDER WITH COMPRESSION CONNECTOR ON LINE SIDE:
WIRE INSTALLING DIESSIZE COPPER ALUMINUM
*8 1/4, 6, TC, 21 –
6 J, TE, 24 5/16, 346, TP
4 5/16, 8, TP, 29 375, TB
2 3/8, 10, TL-TN, 42 1/2, 348, TQ
1/0 1/2, 12, TQ, 42 5/8, BG, TU
2/0 9/16, 13, TS, 45 5/8-1, 297, TWTY
* CU ONLY
The example shown, YFC-4, is a YY Type FuseKit for #4 CU run conductor (#14-6 tap/All Kits).
Select the correct letter or number that suits yourapplication to determine your catalog number.
EXAMPLE
Y F
F=FuseD=Nonfused
C
C=CUA=AL
-4
-8*-6-4-2-1/0-2/0
All Kits
(Wire Size)
Disconnect Kits
NOTE: Fuse kits - accept midget type fuse(non-glass type) 1-1/2 x 13/32, 0-30 amp.(Fuse not included in kit.)
Non-Fused kit - connecting link supplied.
WIRE SIZE
14 - 4 CU
14 - 2 AL
FUSEDCAT. NO.
YFU
NONFUSEDCAT. NO.
YDU
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
50
Flood-Seal”®
Underground Kit
MECHANICAL CONNECTOR INSTALLS WITH 3/16” HEX WRENCH.
MECHANICAL CONNECTOR INSTALLED WITH 1/8” HEX WRENCH.
•
•
Insulated AboveGround Kit
Re-enterable.Tin plated connector.Watertight and submersible.Insulated with “Flood-Seal” EPDM rubber housing.
••••
WIRE SIZECATALOG NUMBERCOPPER ALUMINUM
4-14 2-14 SL3-2K
PVC boot.Tin plated connector.Insulator locks on until removal is necessary.
•••
CATALOG NUMBERAL - CU
CONDUCTOR RANGEBY320 14-2/0
Y-Type Streetlighting Kits
“
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
51
Flood-Seal”® UF Splicing KitHomac’s NEW sealing concept simplifies the fabrication of a waterproofsplice for UF type cables. Through the use of a uniquely designedadapter molded into “Flood-Seal” Splice Covers, direct burial splices forUF type cable are no longer a problem.
NO tape. NO heat. NO mastics. NO mixing or pouring.
Fits sizes 14/2, 12/2, 10/2 with ground.
Fits sizes 14/3, 12/3, 10/3 with ground.
Fully waterproof, submersible and re-enterable.
Not affected by sunlight - UV resistant.
•••••
UF MECHANICAL SPLICING KIT - Order Catalog Number UF3410
TYPICAL WIRE RANGE14/2, 12/2, 10/2 with ground
UF-A SEAL UF-B SEAL
TYPICAL WIRE RANGE14/3, 12/3, 10/3 with ground
FOR FLAT OVAL, UF TYPE CABLE
“
Specially designed UF adapteropening is molded into
“Flood-Seal” splice cover.
Connectorincluded in kit.
Listed E121862
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
WIRE STRAIGHT LUG STACKING LUG INSTALLINGSIZE CATALOG NUMBER CATALOG NUMBER DIES
B H■■ L P W
6 SA6NTN ASL6-NTN
4 SA4NTN ASL4-NTN 52, BG
2-1 SA2NTN ASL2-NTN 243, 5/8 1-1/2 1-1/2 5-1/4 3-1/4 7/8
1/0 AL1/0-NTN ASL1/0-NTN
2/0 AL2/0-NTN ASL2/0-NTN 58, 297, 245, 5/8-1 1-5/8 15/16
3/0 AL3/0-NTN ASL3/0-NTN 66, 167, 247, 737 1-3/4 5-1/2 1-1/16
4/0 AL4/0-NTN ASL4/0-NTN 840, 298, TX2
1-7/86 3-11/32
1-3/16
250 AL250-NTN ASL250-NTN 840, 324, TX 1-1/4
300 AL300-NTN ASL300-NTN 87H, 470, 251, 12-1/4
2
6-9/161-11/32
350 AL350-NTN ASL350-NTN 96, 299, 655, 1-1/8 2-3/8 1-1/2
400 AL400-NTN ASL400-NTN 96, 472, 705, 1-1/8 2-1/2 2-1/2 6-7/83-9/16
1-5/8
500 AL500-NTN ASL500-NTN 106A, 300, 426, 1-5/163
2-5/8 7-5/16
600 AL600-NTN ASL600-NTN 115H, 473, 786, 1-5/16 2-3/4 7-3/4 3-5/81-3/4†
700-750 AL750-NTN ASL750-NTN 140H, 301, 342, 1-1/2 3-5/16 3 8-1/4 3-3/4
800 AL800-NTN ASL800-NTN 140H, 474, 724, 1-5/8 3-13/32 3-1/8 8-5/163-5/8
1000 AL1000-NTN ASL1000-NTN161, 302, 727, 1-3/4
4-11/163-1/4
9-11/16 2-15/32
1000 AL1000-SSN** ASL1000-SSN** 4-9/169-7/8
2-23/32
1250 AL1250-NTN 1-7/8, 727 4-11/16
1500 AL1500-NTN 4785-9/16 10-7/8 3-7/8 3-3/16
1750 AL1750-NTN 204, 729, 40AH
2000 AL2000-NTN 479 6-1/16 11-15/16 3-13/32
52
Tin plated ASL-NTN series lugs size 2-750 and AL-NTN series lugssize 1/0-1000 are listed by Underwriters Laboratories, Inc.“AL-N” series lugs are warranted to meet or exceedrequirements of ANSI C119.4.Save money – stacking lugs double terminal capacity of transformer spades and buses.General purpose aluminum 2 hole NEMA lugs for aluminum andcopper terminations.Made from high conductivity aluminum.Connector bores are coated with efficient Homac compound to preventoxidation and keep moisture out.For easy identification, all lugs marked with a catalog number, conductorsizes and die references.
“AL-N” Series Straight & Stacking LugsTwo Hole NEMA•
••••••
**FEATURE NEMA SPACED SLOTS TO PERMIT SIDE BY SIDE MOUNTING ON NEMA 4 HOLE SPADES.
■ FOR STACKING LUGS ONLY †TRIMMED TO 1-3/4” MAX. TO FIT SIDE BY SIDE ON NEMA SPADES.
ALSO AVAILABLE WITHOUT TIN PLATING, DELETE SUFFIX ‘TN’ FROM CATALOG NUMBERS.
STRAIGHT LUGS ARE AVAILABLE WITH TAPERED ENDS FOR HIGH VOLTAGE USE, PLEASE CONSULT THE FACTORY.
E 50999
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
AL
/ CU
Co
mp
ression
Lu
gs / Term
inals
WIRE BOLT CATALOG INSTALLINGSIZE SIZE NUMBER DIES
B L P W
6 AL6-14TN 5/16, 346, TP 13/16 2-5/32 7/8 9/164 1/4 AL4-14TN 375, TB
12 23/32 5/8
2 AL2-14TN 1/2, 348, TQ 2-5/8 1-1/32 3/4
1/03/8 AL1/0-38TN
5/8, BG, TU 3-1/8 7/81/2 AL1/0-48TN
1-3/82/0
3/8 AL2/0-38TN5/8-1, 297, TWTY 3-3/16 1-5/16 15/16
1/2 AL2/0-48TN
3/03/8 AL3/0-38TN
737, 467 1-9/16 3-7/16 1-1/161/2 AL3/0-48TN
4/03/8 AL4/0-38TN
840, 298, TX 1-1/2 3-9/16 1-3/8 1-3/16AL4/0-48TN
250 AL250-48TN 840, 324, TX 1-5/8 3-5/8 1-1/4300 1/2 AL300-48TN 1, 470, TH 2-1/4 4 1-5/16 1-3/8350 AL350-48TN 1-1/8, 299, 96 2-3/16 4-1/4 1-1/2
400AL400-48TN
1-1/8, 472, 96 2-1/2 4-7/8 1-1/4 1-5/85/8 AL400-58TN
5001/2 AL500-48TN
1-5/16, 300, 106A 5-7/16 1-1/2 1-3/45/8 AL500-58TN
6001/2 AL600-48TN
1-5/16, 473, 115H3
5-11/16 1-9/161-15/16
5/8 AL600-58TN 1-1/2
700 1/2AL750-48-608TN 1-1/2, 608, 125H
750AL750-48TN
1-1/2, 301, 140H3-3/8 6-3/8 1-7/8
1-3/45/8 AL750-58TN
8001/2 AL800-48TN
1-1/2, 474, 140H 3-9/16 6-5/85/8 AL800-58TN
2-1/321-3/16
10001/2 AL1000-48TN
1-3/4, 725, 150H 4-11/16 7-15/16 2-7/165/8 AL1000-58TN
53
AL Series LugsOne Hole• Tin plated AL-TN series lugs are listed by
Underwriters Laboratories, Inc.
• Made of high conductivity aluminum.
• Accepts both aluminum and copper conductors.
• Connector bores are coated with efficient Homac compound to preventoxidation and keep moisture out.
• For easy identification all lugs marked with catalog number, conductor sizesand die references.
“AL” series lugs are warranted to meet or exceed the requirements of ANSI C119.4.ALSO AVAILABLE WITHOUT TIN PLATING, DELETE SUFFIX ‘TN’ FROM CATALOG NUMBERS.AVAILABLE WITH TAPERED ENDS FOR HIGH VOLTAGE USE, PLEASE CONSULT THE FACTORY.
E 50999
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
CONDUCTORS – AL OR CU STRAIGHT LUGS STACKING LUGSCONCENTRIC & COMPACT SOLID
ACSR CATALOG CATALOG INSTALLING B H* L P WCOMPRESSED NUMBER NUMBER DIES
6 4 4 6 SA6-N -TU, 52
5-1/8
4 - 2 4 SA4-N -BG 5-3/16 3-1/4
2 2 & 1 1 - SA3-N -687, 243
1-1/2
1-1/2 7/82 & 1 - 1/0 2 SA2-N ASL2-N
5/85-1/4
1 Str, 1/0 Press 1/0 2/0 1 SA386-N ASL386-N8A
1-7/8 5-1/23-1/4
1/0 2/0 2/0 1/0 AL1/0-N ASL1/0-N 1-1/2 5-1/4
2/0 3/0 3/0 2/0 SA2/0-N SASL2/0-N TX, 76
3/0 4/0 - 3/0 SA3/0-N SASL3/0-N 324, 2492 1-3/4 6 3-3/8
4/0 250 -4/0 SA4/0-N SASL4/0-N
658
250 300 - 840, 11A1-1/4
300 350 - **266.8 SA300-N 655, 96
350 400 - **336.4 SA350-N 2992-1/4 6-1/4
400 500 - **397.5 SA400-N 1-1/8-1, 13A 2-1/26-3/8
3-1/8
500 600 - **477.0 SAB500-N 321, 316 2-3/4
54
“SA-N” SeriesCommon DieStraight & Stacking LugsTwo Hole NEMA• Entire conductor range is installed by only three dies.
• Save money - stacking lugs double terminal capacity of transformer spadesand buses.
• General purpose aluminum 2 hole NEMA lugs for aluminum and copperterminations and for installation on Homac '125 - N' series insulated buses.
• Made from high conductivity aluminum.
• Accept both aluminum and copper conductors.
• Connector bores are coated with efficient Homac compound to preventoxidation and keep moisture out.
• For easy identification, all lugs marked with a catalog number, conductor size and die reference.
“SA-N” series are warranted to meet or exceed Class A requirements of ANSI C119.4.
*FOR STACKING LUGS ONLY **18/1 STRANDING
FOR TIN PLATING ADD SUFFIX ‘TN’ TO CATALOG NUMBER, e.g. SASL4/0-NTN
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
CONDUCTORS – AL OR CU STRAIGHT LUGS STACKING LUGSCONCENTRIC & COMPACT SOLID
ACSR CATALOG CATALOG INSTALLING B H* L P WCOMPRESSED NUMBER NUMBER DIES
8 - 6 - SA8-48 - TU, 52
6 4 4 6 SA6-48 -
4 - 2 4 SA4-48 - BG, 687
2 2 & 1 1 - SA3-48 - 243 1-3/8 3-1/8 1-5/16 7/8
2 & 1 1 1/0 2 SA2-48 ASL2-48 5/8
1Str, 1/0 Comp. 1/0 2/0 1 SA386-48 ASL386-48 8A 1-1/2
1/0 2/0 2/0 1/0 SA1/0-48 ASL1/0-48
2/0 3/0 3/0 2/0 SA2/0-48 SASL2/0-48 TX, 76 1-7/16 3-5/16
3/0 4/0 - 3/0 SA3/0-48 SASL3/0-48 324, 249
4/0 250 -4/0 SA4/0-48 SASL4/0-48
658 1-1/2 1-3/4 3-3/8 1-3/8 1-1/4
250 300 - 840, 11A
300 300 - **266.8 SA300-48 96, 299, 655
350 400 - **336.4 SA350-48 321, 316 1-5/8 3-5/8
400 500 - **397.5 SA400-48 13A, 1-1/8-1
500 600 - **477.0 †CFA500-481-5/16, 14A
2-1/8 1-1/4 1-5/16106A, 300
55
“SA” SeriesCommon DieStraight & Stacking LugsOne Hole• Lessens die inventory - entire conductor range is installed by four dies.
• Save money - stacking lugs double terminal capacity of transformer spadesand buses.
• Designed for general application and for installation on Homac "125" seriesinsulated buses.
• Made from high conductivity aluminum.
• Accept both aluminum and copper conductors.
• Connector bores are coated with efficient Homac compound to preventoxidation and keep moisture out.
• For easy identification, all lugs marked with a catalog number, conductor sizes and die references.
“SA” series are warranted to meet or exceed Class A requirements of ANSI C119.4.
*FOR STACKING LUGS ONLY **18/1 STRANDING
FOR TIN PLATING ADD SUFFIX ‘TN’ TO CATALOG NUMBER, e.g. SA8-48TN. †CENTER FORMED PAD
TO ORDER A STUD SIZE NOT SPECIFIED WITH A TERMINAL LUG ON THIS SHEET, CHANGETHE LAST TWO DIGITS FROM 48 (DESIGNATING 1/2" STUD) TO 38 (FOR 3/8" STUD).
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
56
AluminumTwo Hole Lugs
Aluminum 2-hole NEMA lugs designed for general purpose substation andswitchyard equipment use.
Made from high conductivity aluminum.
Connector bores are coated with efficient Homac compound to preventoxidation and keep moisture out.
All lugs are marked with catalog number, conductor sizes and die references.
Lessens die inventory — compression barrels are designed so that severalcommon dies install the entire range of lugs.
CATALOGNUMBER W B
INSTALLINGDIES
CONDUCTOR SIZEACSR STR
SAK4-NSAK2-N
SAK1/0-NSAK2/0-NSAK3/0-NSAK4/0-NSAK250-NSAB4/0-NSAB250-NSAB300-NSAB350-NSAB400-NSAB500-NSAM4/0-NSAM250-NSAM300-NSAM350-NSAM400-NSAM500-NSAM600-NSAL500-NSAL600-NSAL650-NSAL636-N
SAL750-NSAL800-NSAL1000-NSAL1033-NSAF750-NSAF800-NSAF1000-NSAF1033-N
42
1/02/03/04/02504/0250300
336.4, 350397.5, 400477, 500
4/0250300
336.4, 350397.5, 400477, 500
600477, 500
600600, 636, 650
700
700, 750795, 800
10001033750
795, 80010001033
42
1/02/03/04/04/04/04/0
266.8 (18/1)266.8 (26/7), 336.4 (18/1)336.4 (30/7), 397.5 (18/1)397.5 (30/7), 477 (18/1)
4/04/0
266.8 (18/1)266.8 (26/7), 336.4 (18/1)336.4 (30/7), 397.5 (18/1)397.5 (30/7), 477 (18/1)
477 (24/7 - 30/7)397.5 (30/7), 477 (18/1)
477 (24/7 - 30/7)556.5 (24/7, 26/7)
636 (18/1, 36/1), 605 (24/7)556.5 (30/7)636 (26/7)795 (36/1)
795 (26/7, 30/19)900 (54/7), 954 (45/7)
636 (26/7)795 (36/1)
795 (26/7, 30/19)900 (54/7), 954 (45/7)
6 1 1/4
1 7/82 1/4
2
840, 249EEI - 11A
TX, 76
6 5/81 1/2
1 5/8
3 5/8
1 1/8, 321299, 96, 472
EEI-13A655
8 1 3/4 3 3/41 5/16, 300
EEI-15A106, 317
8 1/4 1 3/4 3 7/81 1/2301140
9 1/82 5/16
2 7/164 5/8
1 3/4302161
IF TIN PLATING IS REQUIRED ADD THE SUFFIX “TN” TO THE CATALOG NUMBER ie: SAL500-NTN
L
•
••
••
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
57
AluminumFour Hole Lugs
Aluminum 4-hole NEMA lugs designed for general purpose substations andswitchyard equipment use.
Made from high conductivity aluminum.
Connector bores are coated with efficient Homac compound to preventoxidation and keep moisture out.
All lugs are marked with catalog number, conductor sizes and die references.
Lessons die inventory - compression barrels are designed so that severalcommon dies install the entire range of lugs.
•
••
••
CATALOGNUMBER
CONDUCTOR SIZEACSR STR. L B
INSTALLINGDIE
SAM4/0-4N
SAM250-4N
SAM300-4N
SAM350-4N
SAM400-4N
SAM500-4N
SAM600-4N
SAL500-4N
SAL600-4N
SAL650-4N
SAL636-4N
SAL750-4N
SAL800-4N
SAL1000-4N
SAL1033-4N
SAF750-4N
SAF800-4N
SAF1000-4N
SAF1033-4N
4/0
4/0
266.8(18/1)
266.8(26/7), 336.4(18/1)
336.4(30/7), 397.5(18/1)
397.5(30/7), 477(18/1)
477(24/7-30/7)
397.5(30/7), 477(18/1)
477(24/7-30/7)
556.5(24/7,26/7)
636(18/1,36/1), 605(24/7)
556.5(30/7)
636(26/7)
795(36/1)
795(26/7,30/19)
900(54/7), 954(45/7)
636(26/7)
795(36/1)
795(26/7,30/19)
900(54/7), 954(45/7)
4/0
250
300
336.4, 350
397.5, 400
477, 500
600
477, 500
600
600, 636, 650
700
700, 750
795, 800
1000
1033
750
795, 800
1000
1033
8 1/4
9
9 1/8
4
4 5/8
4 5/8
1 5/16, 300
EEI -15A
106, 317
1 1/2, 301
140
1 3/4, 302
161
If Tin Plating is required, add the suffix “TN” to the Catalog Number i.e. SAL 500-4NTN.
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
STRAIGHT LUG STACKING LUGWIRE BOLT CATALOG CATALOG INSTALLING B C H■■ L P S WSIZE SIZE NUMBER NUMBER DIES †
61/4 L6-214
7, TE, 242-13/16
5/16 L6-25161-1/8 5/16
2-11/161-5/16 5/8 1/2
41/4 L4-214
5/16, 8, TP, 29 2-3/45/16 L4-2516
21/4 L2-214
3/8, 10, TL-TN, 33 1-1/43-1/8 1-1/2
5/85/16 L2-2516 3/8 3-5/16
11/4 L1-214
3/8, 11, TB, 371-3/8
3-3/83/4 & 7/8
11/165/16 L1-2516 1-1/2 5/16 1-5/83/8 L1/0-238
1-3/8 3/8 3-7/167/8
1/0 5/16 L1/0-2516 1/2, 12, TQ, 42 3/4 & 7/8 3/41/2 L10-N 4-7/8
2/03/8 L2/0-238
9/16, 13, TS, 45 5-1/16 7/81/2 L2/0-N SL2/0-N 1-1/2
3/03/8 L3/0-238
5/8, 14, TU, 501-1/2
5-1/8 15/161/2 L3/0-N SL3/0-N 1-5/8
4/03/8 L4/0-238
5/8-1, 15, TW-TY, 541/2 L4/0-N SL4/0-N 1-5/8 1-11/16 5-3/16 31-1/16
2503/8 L250-238
11/16, 16, TR, 601/2 L250-N SL250-N 1-3/4 1-3/4 5-7/161-1/8
3003/8 L300-238
737, 17, TV, 665/8 1-3/4
1-1/41/2 L300-N SL300-N 1-13/16
3503/8 L350-238
840, 18, TX, 712 5-3/4
1-5/161/2 L350-N SL350-N 1-7/8 1-7/8
4003/8 L400-238
15/16, 19, TX, 76 2-1/8 63-1/16
1-7/16L400-N SL400-N 1-15/16500 L500-N SL500-N 1, 20, TH, 87 2-1/4 2-1/16 6-1/16
3-1/81-9/16
600 L600-N SL600-N 1-1/8, 22 96 2-5/8 2-3/16 6-3/4 1-11/16750 1/2 L750-N SL750-N 1-5/16, 24, 106 2-13/16 2-5/16 7 1-3/41000 L1000-NT SL1000-NT 1-1/2, 27, 125 2-15/16 2-5/8 7-1/4 3-1/4 1-3/4*1500 L1500-N 1-3/4, 31, 150
3-3/167-1/2 3 2-11/16
2000 L2000-N 200, 34, 175 8-1/16 3-3/16 3-1/16
58
■■ FOR STACKING LUGS ONLY.
FOR OTHER SIZES AVAILABLE, PLEASE CONSULT THE FACTORY.
*TRIMMED TO 1-3/4" MAX. TO FITSIDE BY SIDE ON NEMA SPADES.
Copper LugsTwo HoleStraight & Stacking• “L” and “SL” copper lugs are listed by Underwriters
Laboratories, Inc.
• L2-214 - L1/0-2516 feature slotted rear bolt hole providing 3/4and 7/8 bolt hole centers for added versatility. Other combinationsavailable - consult factory.
• General applications long barrel compression lugs.
• Produced from seamless high conductivity copper tubing.
• Hot tin dipped to provide corrosion resistance.
• Marked with a catalog number, conductor sizes and die references.
File LR 35518
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
59
Copper LugsHeavy Duty• Made from heavy wall electrolytic grade seamless copper
tubing for the most severe heavy loading applications.
• Generous inside chamfers are provided to ease cable insertion.
FOR TIN PLATING ADD SUFFIX ‘TN’ TO CATALOG NUMBER, e.g. HDL 2-NTN.
COMPOUND AVAILABLE UPON REQUEST.
WIRE SIZE CATALOG INSTALLING B L P WNUMBER DIES
2 HDL2-N TQ, 42, 163, 1/213/16
1 HDL1-N TS, 45, 241, 1/2 1-1/2 5-1/4
1/0 (7-19 STR) HDL1/0-N TU, 50, 165, 5/8 7/8
2/0 (7-19 STR) HDL2/0-N TZ, 166, 5/8-1 1-3/4 5-1/2 15/16
3/0 (7-19 STR) HDL3/0-N 60, 16, 166, 206 1-11/16 5-3/163
1-7/16
4/0 (7-19 STR) HDL4/0-N 71, 168, 8401-3/4
5-1/4 1-1/4
250 (19-37 STR) HDL250-N 80, 169 5-5/8 1-5/16
300 (19-37 STR) HDL300-N 87, 170, 1 2-1/4 5-13/16 1-3/8
350 (19-37 STR) HDL350-N 96, 267, 1-1/8-1 2-5/16 6-9/16 1-1/2
500 (19-37 STR) HDL500-N 112, 210, 1-5/16 2-5/8 6-3/8 1-3/4
600 (37-61STR) HDL600-N 125, 608, 1-1/2 3 7-1/2 3-5/8 1-15/16
750 (37-61 STR) HDL750-N 138, 627, 1-5/8 3-3/8 7-3/16 3 2-3/16
1000 (37-61 STR) HDL1000-N 160, 345, 2 4-5/8 9-5/8 3-5/8 2-5/8
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
5/16 L3/0-516 3/83/0 3/8 L3/0-38 5/8, 14, 1-1/2 3-1/8 1 15/16
1/2 L3/0-48TU, 50 9/16
5/16 L4/0-5165/8-1, 15,
3/8 3 7/8
4/0 3/8 L4/0-3/8TW-TY, 54 1-9/16
9/16 3-1/41-1/8 1
1/2 L4/0-48 1
WIRE BOLT CATALOG INSTALLINGSIZE SIZE NUMBER DIES †
B C L P W
8 - 10 L8-105/16 1-13/16 5/8 7/16
81/4 L8-14 1/4, 6,
15/16 L8-516 TC, 21
1-15/16 5/83/8 L8-38
1/4 L6-147, 2-1/8
3/41/2
6 5/16 L6-516TE, 24 1-1/8
2-1/4 9/163/8 L6-38
1/4 L4-14 3/8
4 5/16 L4-516 5/16, 8, 1- 3/16 2-3/8 1/2
3/8 L4-38 TP, 29 7/8 9/161/4 L2-14
25/16 L2-516 3/8, 10,
1-1/42-1/2 5/8
3/8 L2-38 TL-TN, 33
1/2 L2-48 9/16 2-3/4 1-1/8 3/41/4 L1-14
15/16 L1-516 3/8, 11, 1-3/8 3/8 2-11/16 7/8 11/163/8 L1-38 TB, 371/2 L1-48 9/16 2-7/8 1-1/85/16 L1/0-516 1/2, 12, 3/8 2-3/4 7/8 3/4
1/0 3/8 L1/0-38 TQ, 42 1-7/161/2 L1/0-48 9/16 2-15/16 1
5/16 L2/0-516 9/16, 13 3/8 2-7/8 7/813/162/0 3/8 L2/0-38 TS, 45 1-1/2
1/2 L2/0-48 9/16 3-1/8 1-1/8
60
Copper LugsOne Hole• "L" series tin plated, 1-hole, copper lugs are
listed by Underwriters Laboratories, Inc.
• Produced from seamless high conductivity copper tubing.
• Hot tin dipped to provide corrosion resistance.
• Marked with a catalog number, conductor sizes and die references.
ALL DIMENSIONS ARE SHOWN IN INCHES.
CONTINUED ON NEXT PAGEFOR "L" SERIES LUGS WITH TAPERED ENDS FOR HIGHVOLTAGE USE, PLEASE CONSULT THE FACTORY.
File LR 35518
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
WIRE BOLT CATALOG INSTALLINGSIZE SIZE NUMBER DIES †
B C L P W
5/16 L250-516 3/8 3-3/16 7/8
250 3/8 L250-38 11/16, 16, 1-5/8 1-1/8
1/2 L250-48TR, 60 3-3/8
3003/8 L300-38 781, 17,1/2 L300-48 TV, 66 9/16
3-13/161-1/8 1-1/4
3503/8 L350-38 840, 18, 2 3-7/8 1-5/161/2 L350-48 TX, 71
3/8 L400-38 3-15/16400 1/2 L400-48 15/16, 19, 1-7/16
5/8 L400-58TX, 76 4-3/16
5001/2 L500-48 1, 20 2-1/4 4-1/2
1-3/81-9/16
5/8 L500-58 TH, 87
6001/2 L600-48 1-1/8, 22 2-5/8
11/165-5/16
1-3/4 1-3/45/8 L600-58 96 5-1/8
1/2 L750-481-5/16, 24,
750 5/8 L750-58 106 2-7/8 5-5/8 1-15/16 1-15/16
3/4 L750-681/2 L1000-48
1000 5/8 L1000-581-1/2, 27,
3 6 2-1/8 2-3/163/4 L1000-68
125
61
COPPER LUGS, ONE HOLE, CONT'D.
Copper Lugs Four Hole• Produced from seamless high conductivity copper tubing.
• Hot tin dipped to provide corrosion resistance.
• Marked with catalog number, conductor sizes and die references.
Aluminum Lugs Four Hole• General purpose 4 hole NEMA lugs for use with aluminum
or copper conductors.
• Made from high conductivity aluminum, and coated with efficientHomac compound to prevent oxidation and keep moisture out.
• Marked with catalog number, conductor sizes and die references.
WIRE BOLT CATALOG INSTALLINGSIZE SIZE NUMBER DIES
B C L P W
1000 1/2 L1000-4N 1-1/2, 27, 125 2-3/4 5/8 8-1/4 3-1/4 31500 1/2 L1500-4N 1-3/4, 31, 150 3-3/16 5/8 7-1/2 3 2-5/8
2000 1/2 L2000-4N 2.00, 34, 175 3-3/16 5/8 8-1/16 3-3/16 3-1/16
ALL DIMENSIONS ARE SHOWN IN INCHES.
WIRESIZE
100012501500175020002500
CATALOGNUMBER
AL1000-4NAL1250-4NAL1500-4NAL1750-4NAL2000-4NAL2500-4N
INSTALLINGDIES
161, 302, 352, 292, 319, 1-3/4161, 727, 352189, 478, 728
214, 735, 225, 204, 40AH225, 735, 44AH
214
B
4-5/84-11/165-9/165-1/26-3/49-1/8
L
1010
10-3/410-11/1611-7/815-3/8
P
43-9/163-9/163-5/83-5/8
4
W
333
3-1/23-1/23-1/2
C
5/85/85/87/85/8
1-1/8
N
1-3/4
BOLTSIZE
1/2
FOR TIN PLATING ADD SUFFIX ‘TN’ TO CATALOG NUMBER, e.g. AL1000-4NTN
File LR 35518
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
WIRE BOLT CATALOG INSTALLINGSIZE SIZE NUMBER DIES †
B C L P W
810 HL8-10 1/4, 6, 1/2 5/16 1-5/16 5/8 7/161/4 HL8-14 TC, 21
8-10 HL6-101/2
61/4 HL6-14 J, 7
13/16 1-3/4 3/45/16 HL6-516 TE, 24
9/163/8 HL6-38
8-10 HL4-10
1/4 HL4-14 5/16, 8, 15/163/8 1/2
45/16 HL4-516 TP, 29 1
3/8 HL4-38 7/8 5/81/4 HL2-14
25/16 HL2-516 3/8, 10, 2 5/83/8 HL2-38 TLTN, 33
1/2 HL2-48 7/8 9/16 2-3/16 1-1/8 3/41/4 HL1-14
15/16 HL1-516 3/8, 11, 3/8 2 7/8 11/163/8 HL1-38 TB, 371/2 HL1-48 9/16 2-3/16 1-1/85/16 HL1/0-516
1/2, 12, 3/8 2-1/8 7/8 3/41/0 3/8 HL1/0-38 TQ, 42
1/2 HL1/0-48 9/16 2-1/4 1-1/8
5/16 HL2/0-5169/16, 13
15/16
3/8 2-1/16 7/813/162/0 3/8 HL2/0-38 TS, 45
1/2 HL2/0-48 9/16 2-5/16 1-1/8
62
Peep HoleCopper LugsOne Hole andTwo Hole NEMA• “H-L” series, 1-hole, "Peep-Hole" copper lugs are
listed by Underwriters Laboratories, Inc. through1000 MCM.
• Allows inspection of the termination to assure complete cable insertion.
• Produced from high conductivity seamless copper tubing.
• Tin plated to provide corrosion resistance.
• Marked with a catalog number, conductor sizes and die references.
PEEP HOLE COPPER 1-HOLE LUGS
CONTINUED NEXT PAGE
ALL DIMENSIONS ARE SHOWN IN INCHES.
File LR 35518
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
WIRE BOLT CATALOG INSTALLINGSIZE SIZE NUMBER DIES
B C L P S W
2/0 HL2/0-N 9/16, 13, TS, 45 4-1/2 13/16
3/0 HL3/0-N 5/8, 14, BG, 50 15/16 4-5/8 15/16
4/0 HL4/0-N 5/8-1, 15, TW-TY, 54 4-11/16 1-1/16
250 HL250-N 11/16, 16, TR, 60 4-3/4 1-1/16
300 HL300-N 737, 17, TV, 661
4-13/16 1-3/16
350 1/2 HL350-N 840, 18, TX, 71 1-1/8 5/8 4-15/16 3 1-3/4 1-5/16400 HL400-N 15/16, 19, TX, 76 1-3/16 5-1/8 1-3/8
500 HL500-N 1, 20, TH, 87 1-3/8 5-5/16 1-9/16600 HL600-N 1-1/8, 22, 96 1-3/8 5-1/2 1-11/16750 HL750-N 1-5/16, 24, 106 1-5/8 5-3/4 1-15/161000 HL1000-N 1-1/2, 27, 125 1-7/8 6-3/16 2-3/161500 HL1500-N 1-3/4, 31, 150 2 6-9/16 2-11/162000 HL2000-N 2, 34, 175 2-1/4 7 3-1/16*1500 HL1500-4N 1-3/4, 31, 150 2 6-9/16 3-1/8*2000 HL2000-4N 2, 34, 175 2-1/4 7 3-1/16
WIRE BOLT CATALOG INSTALLINGSIZE SIZE NUMBER DIES
B C L P W
5/16 HL3/0-516 1-1/8 3/8 7/83/0 3/8 HL3/0-38 5/8, 14,
1-3/16 2-1/21 15/16
1/2 HL3/0-48BG, 50
1-1/89/16
5/16 HL4/0-5165/8-1, 15,
3/8 2-7/16 7/8
4/0 3/8 HL4/0-38TW-TY, 54 2-9/16
11/2 HL4/0-48
3/8 HL250-38 11/16, 16 1-3/16 9/16 1-1/81-1/8250
1/2 HL250-48 TR, 60, 2-11/16
1/2 HL300-48 781, 17, TV 3005/8 HL300-58 66 11/16
2-13/161-3/8
1-3/16
1/2 HL350-48 840, 18, 1-3/8 9/161-1/16350
5/8 HL350-58 TX, 71 1-1/42-15/16 1-5/16
4001/2 HL400-48 15/16, 19,5/8 HL400-58 TX, 76 1-1/2
11/16 3-5/16 1-3/8
5001/2 HL500-48 1, 20 1-3/8
1-9/165/8 HL500-58 TH, 87 1-3/4 3-9/16
6001/2 HL600-48 1-1/8-1, 22 1-7/16 3-7/8 1-3/4 1-11/165/8 HL600-58 961/2 HL750-48 7/8
750 5/8 HL750-58 1-1/8-2, 24,1-5/8 4-3/8 1-15/16 1-15/16
3/4 HL750-68106
1/2 HL1000-481-1/2, 27
15/161000 5/8 HL1000-58 125
1-15/16 4-15/16 2-1/8 2-3/163/4 HL1000-68 1-1/16
1500 HL1500-68 1-3/4, 31, 150 2 1-1/8 5-1/2 2-1/4 2-11/162000
3/4HL2000-68 2, 34, 175 2-1/4 1-3/16 5-15/16 2-3/8 3-1/16
63
PEEP HOLE COPPER 1-HOLE LUGS, CONT'D.
PEEP HOLE COPPER 2-HOLE
AND
* 4-HOLE NEMA LUGS
ALL DIMENSIONS SHOWN IN INCHES.
File LR 35518
File E50999
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
WIRE CATALOG L B INSTALLINGSIZE NUMBER DIES
4 AC-4 3-3/16 1-7/16 TB, 37, 375, 162
2 AC-2 3-15/32 1-5/8 TQ, 45, 348, 6A, 1/2
1 AC-1 3-1/2 1-5/8 TQ, 45, 348, 6A, 1/2
1/0 AC-1/03-11/16
1-7/16 TU, BG, 8A, 5/8, 52, 243
2/0 AC-2/0 1-3/4 TWTY, 297, 9A, 5/8-1, 58
3/0 AC-3/0 4 1-7/8 10A, 737, 66, 247
4/0 AC-4/0 4 2 TX, 298, 11A, 840, 71H
250 AC-250 5-1/4 2-7/16 TX, 11A, 840, 76, 249
300 AC-300 5-3/4 2-11/16 TH, 12A, 87H, 251
350 AC-350 6-5/8 3-1/4 96, 299, 13A, 94H
400 AC-400 7-9/32 3-7/16 96, 13A, 99H, 655
500 AC-500 7-19/32 3-5/8 106A, 106, 14A, 317, 300
600 AC-600 7-27/32 3-3/4 115H, 473, 112H
700-750 AC-750 8-9/32 4 140H, 301
800 AC-800 8-1/2 4-1/16 140H, 474
1000 AC-1000 9-15/16 4-13/32 302, 161
1250 AC-1250 10 4-5/8 161, 352, 579
1500 AC-1500 13 6-11/32 478, 189
1750 AC-1750 13 6-5/16 204, 729, 40AH
2000 AC-2000 15-1/16 7-11/32 735, 214
WIRE CATALOG L B INSTALLINGSIZE NUMBER DIES
6 ASC6TN 1-5/8 3/4 TP, 29, 346, 161, 5/16
4 ASC4TN 2 1 TB, 37, 375, 162
2 ASC2TN2 15/16
TQ, 45, 348, 6A, 1/2, 163
1 ASC1TN TQ, 45, 348, 6A, 1/2, 163
1/0 ASC1/0TN 2-1/8 1 TU, BG, 8A, 5/8, 52, 243
2/0 ASC2/0TN 2-5/16 1-3/32 TWTY, 297, 9A, 5/8-1, 58
3/0 ASC3/0TN 2-5/8 1-1/4 10A, 737, 66, 247
4/0 ASC4/0TN 2-3/4 1-5/16 TX, 298, 11A, 840, 71H
250 ASC250TN 2-15/16 1-3/8 TX, 11A, 840, 76, 249
300 ASC300TN 3-1/8 1-7/16 TH, 12A, 87H, 251
350 ASC350TN 3-3/8 1-19/32 96, 299, 13A, 94H
400 ASC400TN 3-3/4 1-25/32 96, 13A, 655, 99H
500 ASC500TN 3-7/8 1-27/32 106A, 14A, 300, 317
600 ASC600TN 4-1/8 1-15/16 115H, 473, 786, 936, 112H
750 ASC750TN 4-11/16 2-5/32 140H, 301
800 ASC800TN 4-3/4 2-1/4 140H, 474
1000 ASC1000TN 5-1/4 2-1/2 302, 161
1500 ASC1500TN 6-1/2 3-1/16 478, 189
2000 ASC2000TN 7-1/2 3-9/16 735, 214
64
“ASC-TN” series tin plated aluminum splices arelisted by Underwriters Laboratories, Inc.
Designed for general application.
Made of high conductivity aluminum.
Solid center stop assures proper cable insertion.
Accepts both aluminum and copper conductors.
Connector bores are coated with efficient Homacconnector compound and capped.
Marked with catalog number, conductor sizesand die references.
“ASC” SeriesAluminum Splices••••••
•
•••
•
•••
Designed for general application.
Made of high conductivity aluminum.
Solid center stop assures proper cable insertion.
Accepts both aluminum and copperconductors.
Connector bores are coated with efficient
Homac connector compound and capped.
Marked with catalog number, conductorsizes and die references.
“AC” SeriesAluminum Splices
“AC” series are warranted to meet or exceed the requirements of ANSI C119.4.
FOR TIN PLATING ADD SUFFIX “TN” TO CATALOG NUMBER, e.g. AC-350 TN.
“ASC” series are warranted to meet or exceed the requirements of ANSI C119.4.
IF TIN PLATING IS NOT DESIRED, DELETE THE ‘TN’ FROM THE CATALOG NUMBER.
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
65
WIRE SIZECATALOGNUMBER
INSTALLINGDIES B L
2
1/0
2/0
3/0
4/0
250
300
350
400
500
600
700-750
800
1000
1250
1500
1750
2000
ATC-2
SATC-1/0
ATC-2/0
ATC-3/0
ATC-4/0
ATC-250
ATC-300
ATC-350
ATC-400
ATC-500
ATC-600
ATC-750
ATC-800
ATC-1000
ATC-1250
ATC-1500
ATC-1750
ATC-2000
348, 6A, TQ, 45
243, 8A, TU, 52
245, 9A, TWTY, 58
247, 10A, TV, 66
298, 11A, TX, 71
249, 11A, TX, 76
251, 12A, TH, 87
299, 13A, 96
472, 13A, 96
300, 14A, 106, 317
473, 115
301, 140
474, 140
302, 161
161, 302
478, 189
204, 729, 40AH
479, 225
1-9/32
1-7/16
1-3/4
2-3/32
2-9/32
2-9/16
2-11/16
2-31/32
3-3/8
3-5/84-11/32
4-5/8
5-1/2
5-11/16
2-11/16
3
3-1/16
3
3-21/32
4-5/16
5-7/32
5-1/2
6-1/32
6-27/32
7-5/168-27/32
9-3/4
11-1/2
11-7/8
WIRE SIZECATALOGNUMBER
INSTALLINGDIES B L
4
2
1/0
2/0
3/0
4/0
250
300
350
400
500
600
700-750
SATC 4
SATC 2
SATC 1/0
SATC 2/0
SATC 3/0
SATC 4/0
SATC 250
SATC 300
SATC 350
SATC 400
SATC 500
SATC 600
SATC 700-750
52, TU, 8A, 296, 243, 5/8
76, 11A, 249, 298, 840
96, 13A, 1-1/8,299, 321, 705
115, 15A, 300, 1-5/16
1-1/2, 301, 140, 724, 342
140, 301
1-7/16
1-7/8
2-5/16
2-5/8
3-5/16
3-3/8
3
4
5
5-1/2
7
6-27/32
Aluminum Tapered Splices
Ends tapered for high voltageapplications to 69 KV.
Accepts combinations of aluminum or copper cables.
Solid center stop assures proper cable insertion.
Connector bores coated with efficient Homac compound.
Marked with catalog number, and die references.
•••••
COMMON DIE SERIES Aluminum Tapered Splices
“ATC” series splices are warranted to meet or exceed Class A requirements of ANSI C119.4.FOR TIN PLATING, ADD SUFFIX ‘TN’ TO CATALOG NUMBER, e.g. ATC-2 TN.
All the features as ‘ATC’ seriestapered splices shown above.
All connector sizes can be installed with six dies.
••
“SATC” series splices are warranted to meet or exceed Class A requirements of ANSI C119.4.FOR TIN PLATING, ADD SUFFIX ‘TN’ TO CATALOG NUMBER, e.g. SATC 4 TN.
AL
/ CU
Co
mp
ression
Sp
lices
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
66
AluminumTapered Reducing Splices
Ends tapered for high voltage applications to 69KV.
Accept combinations of aluminum or copper cables.
Solid center stop assures proper cable insertion.
Connector bores coated with efficient oxide inhibitingcompound.
Marked with catalog number, conductor sizes and diereferences.
••••
•
WIRE SIZE
FROM TOCATALOGNUMBER
INSTALLINGDIES L B
1/02/03/04/04/035035050050075075075010001000
22
1/01/02/04/02504/03504/0350500500750
ATC1/0R2ATC2/0R2
ATC3/0R1/0ATC4/0R1/0ATC4/0R2/0ATC350R4/0ATC350R250ATC500R4/0ATC500R350ATC750R4/0ATC750R350ATC750R500ATC1000R500ATC1000R750
243, 5/8, TU
249, 840, TX
655, 299, 1-18-1, 96, 13A
300, 317, 1-5/16, 106, 15A
301, 1-1/2, 140
302, 1-3/4, 161
3
4
6-5/8
8-1/2
9-7/8
1-7/16
1-7/8
3-1/8
4-1/2
4-3/8
“ATC-R” series are warranted to meet or exceed Class A requirements of ANSI C119.4.
FOR TIN PLATING ADD SUFFIX ‘TN’ TO CATALOG NUMBER, e.g. ATC1/0R2TN.
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
67
Designed for general URD application.
Entire conductor range is installedby six dies.
Made of high conductivity aluminum.
Solid center stop assures propercable insertion.
Accept both aluminum and copper conductors.
Connector bores are coated withoxide inhibiting compound.
Marked with catalog numbers,conductor sizes and die references.
SAC SeriesAluminum Splices
••
••
•
•
•
•
•
••
••
•
“SAC” series are warranted to meet or exceed Class A requirements of ANSI C119.4
“SAC-R” series are warranted to meet or exceed Class A requirements of ANSI C119.4
FOR TIN PLATING ADD SUFFIX ‘TN’ TOCATALOG NUMBER, e.g. SAC4TN.
FOR TIN PLATING ADD SUFFIX ‘TN’ TOCATALOG NUMBER, e.g. SAC4R6TN.
WIRE CATALOG INSTALLING B LSIZE NUMBER DIES
4 SAC 48A, 5/8
2 SAC 2TU, 52 1-7/16 3
1 SAC 1BC, 243
1/0 SAC 1/0
2/0 SAC 2/0 11A
3/0 SAC 3/0 840
4/0 SAC 4/0 2491-7/8 4
250 SAC 250 TX, 76
300 SAC 300 13A, 1-1/8-12-3/8 5
350 SAC 350 96, 299, 655
400 SAC 400 15A, 106A, 1-5/162-11/16 5-11/16
500 SAC 500 115H, 300, 317
600 SAC 600 301
700-750 SAC 750 1-1/2 3-3/8
800 SAC 800 140 7
1000 SAC 1000 292, 302, 1-3/4, 161, 319, 352 3-5/16
Aluminum to Copper ReducersCommon Die Series
Reducers-enlargers for generalURD application.
Entire conductor range is installed by six dies.
Made of high conductivity aluminum.
Solid center stop assures propercable insertion.
Accepts aluminum or copper conductor.
Connector bores are coated with oxideinhibiting compound.
Marked with catalog numbers, conductorsizes and die references.
Common Die Series
WIRE SIZE CATALOG INSTALLING B LFROM TO NUMBER DIES
4 6 SAC4R6 8A
2 4 SAC2R4 TU, 52 1-7/16 3
1/0 2 SAC1/0R2 5/8, BG, 243
2/0 2 SAC2/0R2
3/0 1/0 SAC3/0R1/0 840
4/0 2 SAC4/0R2 249
4/0 1/0 SAC4/0R1/0 11A 1-7/8 4
4/0 2/0 SAC4/0R2/0 TX, 76
250 2/0 SAC250R2/0
250 3/0 SAC250R3/0
250 4/0 SAC250R4/0
300 3/0 SAC300R3/0 1-1/8-1
300 250 SAC300R250 13A2-7/16 5
350 4/0 SAC350R4/0 96
350 250 SAC350R250 299
500 4/0 SAC500R4/0 15A, 1-5/162-11/16 5-11/16
500 350 SAC500R350 106
750 350 SAC750R350 140H, 1-1/2
750 500 SAC750R500 3013 6-3/16
1000 500 SAC1000R500 161, 302, 3193-7/8 8
1000 750 SAC1000R750 292, 1-3/4, 352
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
68
Aluminum toCopperReducers
Reducer for general application.
Made of high conductivity aluminum.
Solid center stop assures proper cable insertion.
Accepts both aluminum and copper conductors.
Connector bores are coated with efficient Homac connectorcompound and capped.
Marked with catalog number, conductor sizes and diereferences.
•••••
•
WIRE SIZE
FROM TOCATALOGNUMBER
INSTALLINGDIES B L
2
1/0
2/0
3/0
4/0
250
300
350
400
500
500
500
600
600
750
750
1000
1000
AC 2R 4
AC 1/0R 2
AC 2/0R 1
AC 3/0R 1/0
AC 4/0R 2/0
AC 250R 3/0
AC 300R 4/0
AC 350R 4/0
AC 400R 250
AC 500R 300
AC 500R 350
AC 500R 400
AC 600R 350
AC 600R 500
AC 750R 500
AC 750R 600
AC 1000R 500
AC 1000R 750
4
2
1
1/0
2/0
3/0
4/0
4/0
250
300
350
400
350
500
500
600
500
750
TQ, 45, 348, 6A, 1/2
8A, BG, TU, 5/8
TWTY, 60, 245, 9A, 5/8-1
781, TU, 56
TX, 71H, 298, 11A, 840
840, 11A, 249, TX
96, 299, 1-1/8
96, 472, 1-1/8
106, 300, 317, 1-5/16
115, 473, 1-5/16
140, 301, 1-1/2
161, 302, 1-3/4
1-7/8
2
2-1/8
2-5/8
3-17/32
3-11/16
3-13/16
3-15/16
4-7/32
4-5/8
4-9/16
5
5-1/4
6-5/16
8-3/16
8-19/32
8-11/16
8-7/8
9-1/4
9-5/8
9-7/8
“AC-R” SERIES ARE WARRANTED TO MEET OR EXCEED CLASS A REQUIREMENTS OF ANSI C119.4.
FOR TIN PLATING, ADD SUFFIX ‘TN’ TO CATALOG NUMBER, e.g. AC 300R 4/0 TN.
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
69
SG Series TinnedAluminum SplicesOne Die Installs Entire SeriesOne Connector Accepts Compact,Compressed and Concentric Strand Wire
Designed specifically for underground service splicing.
One insulator, *FSS20, provides watertight protection for the entire series.
Forged from high conductivity aluminum.
Electrotinned to resist corrosion and extend shelf life.
Solid center stop assures accurate wire positioning and forcesoxide inhibitor over and through conductor strands.
Oxide inhibitor compound improves contact and seals out moisture after installation.
Color coded end caps seal splices from contaminants.
Marked with catalog number, conductors sizes, die referencesand compression locations.
•••••
•
••
A
8
6
4
2
1
1/0
2/0
B
8
6
8
6
4
6
4
2
1
6
4
2
1/0
6
4
2
1/0
2/0
CATALOGNUMBER
SG88
SG68
SG66
SG48
SG46
SG44
SG26
SG24
SG22
SG11
SG106
SG104
SG102
SG1010
SG206
SG204
SG202
SG2010
SG2020
WIRE SIZE CONDUCTOR
AL-CU AL-CU 2
2-1/8ALUM
ALUM
5/8, 8ABG, TU
243
INSTALLINGDIESA B L
‘SG’ Series are warranted to meet or exceed the requirements of ANSI C119.4
*FSS20, “Flood-Seal” insulating splice covers are ordered separately.
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
70
WIRESIZE
CATALOGNUMBER B BL L
CATALOGNUMBER
INSTALLINGDIES
86421
1/02/03/04/0250300350400500600750100015002000
C-8C-6C-4C-2C-1
C-1/0C-2/0C-3/0C-4/0C-250C-300C-350C-400C-500C-600C-750
C-1000C-1500C-2000
SC-8SC-6SC-4SC-2SC-1
SC-1/0SC-2/0SC-3/0SC-4/0SC-250SC-300SC-350SC-400SC-500SC-600SC-750SC-1000SC-1500SC-2000
7/1613/1613/167/87/87/8
15/1611
1-1/161-1/161-1/81-3/161-3/81-3/81-5/81-7/8
22-1/4
1-1/161-3/41-3/41-7/81-7/81-7/8
22-1/82-1/82-1/42-1/42-3/82-1/22-7/82-7/83-3/83-7/84-1/84-5/8
1-1/161-1/81-1/81-1/41-3/81-3/81-1/21-1/21-5/81-5/8
22
2-1/82-1/4
2-11/162-7/8
33-3/163-7/16
2-1/42-3/82-3/82-5/82-7/82-7/83-1/83-1/83-3/83-3/84-1/84-1/84-3/84-5/85-1/25-7/86-1/86-1/2
7
1/4, 6, TC, 21, 236TE, 24
5/16, 8, 29, 161, TJ3/8, 10, TL-TN, 33, 162
11, TB, 371/2, 12, TQ, 42, 1639/16, 13, TS, 45, 164
5/8, 14, TU, 50, 243, BG5/8-1, 15, TW-TY, 54
11/16, 16, TR, 60, 16617, 66, TV, 781840, 18, TX,71
15/16, 19, TX, 761, 20, TH, 87, 251
1-1/8-1, 22, 961-1/8, 2, 24, 106
1-1/2, 27, 125, 6421-3/4, 31, 1502.00, 34, 175
Tinned CopperSplices
SC and C series tinned copper splices are listed byUnderwriters Laboratories, Inc.
Produced from seamless electrolytic copper tubing.
Tin plated to inhibit corrosion.
Dimpled center stops to equalize cable insertion.
Marked with catalog number, conductor sizes anddie references.
•
••••
File LR 35518
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
71
WIRESIZE
DimpledCenter StopCat. Number
INSTALLINGDIES B L
6421
1/02/03/04/0250300350400500600750100015002000
TC-6TC-4TC-2TC-1
TC-1/0TC-2/0TC-3/0TC-4/0TC-250TC-300TC-350TC-400TC-500TC-600TC-750TC-1000TC-1500TC-2000
J, 7, TE, 245/16, 8, TP, 29
3/8, 10, TL-TN, 333/8, 11, TB, 371/2, 12, TQ, 429/16, 13, TS, 455/8, 14, TU, 50
5/8-1, 15, TW-TY, 5411/16, 16, TR, 60
737, 17, 66840, 18, TX, 71
15/16, 19, TX, 761, 20, TH, 871-1/8, 22, 96
1-5/16, 24, 1061-1/2, 27, 1251-3/4, 31, 1502.00, 34, 175
7/8
31/32
1-1/32
1-1/8
1-7/321-1/4
1-5/161-7/16
1-11/16
2-1/16
2-7/163-7/32
3-15/32
1-29/32
2-1/16
2-7/322-13/322-3/8
2-9/162-5/8
2-25/322-31/323-17/32
4-7/32
4-31/326-1/2
6-11/16
Solid CenterOil Stop
Cat. Number
PTC-6PTC-4PTC-2PTC-1
PTC-1/0PTC-2/0PTC-3/0PTC-4/0PTC-250PTC-300PTC-350PTC-400PTC-500PTC-600PTC-750
PTC-1000PTC-1500PTC-2000
Tapered CopperSplices & Tapered CopperOil-Stop Splices
Ends tapered for high voltage applications to 69KV.
Made from pure electrolytic copper.
Tin plated for corrosion resistance.
Dimpled center stop to equalize cable insertion.
Indents should be filled with enert material.
'TC' series has dimpled center stop to equalize cable insertion.
'PTC' series has solid center, where oil stops are required.
•••••••
Copper StraightOil-Stop Splices
Fabricated from quality - seamless electrolyticcopper tubing to prevent splitting.
No oil seepage with silver brazed oil-stop plugs.
Tin plating provides high corrosion resistance.
These splices feature double crimp length foradded mechanical strength.
•
•••
'TC' Dimple Style
'PTC' Solid Center Oil Stop
WIRESIZE
CATALOGNUMBER
INSTALLINGDIES B L
6421
1/02/03/04/0250300350400500600750800
1000
PC-6PC-4PC-2PC-1
PC-1/0PC-2/0PC-3/0PC-4/0PC-250PC-300PC-350PC-400PC-500PC-600PC-750PC-800PC-1000
7, TE, 245/16, 8, TP, 29, 1613/8, 10, TL-TN, 1623/8, 11, TB, 37, 2761/2, 12, TQ, 42, 163
9/16, 13, TS, 1645/8, 14, TU, 2435/8-1, 15, 165
11/16, 16, TR, 166737, 17, 167
840, 18, TX, 16815/16, 19, TX, 169
1, 20, 1701-1/8-2, 22, 96, 3161-5/16, 24, 106, 3171-5/16, 25, 112, 300
1-1/2, 27, 125
1-1/8
1-1/4
1-3/8
1-1/2
1-5/8
2
2-1/82-1/4
2-11/162-7/8
2-15/163
2-3/8
2-5/8
2-7/8
3-1/8
3-3/8
4-1/8
4-3/84-5/85-1/25-7/8
66-1/8
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
72
LOW VOLTAGETEE
CAT. NUMBER
AT2-2
AT1/0-1/0
AT1/0-2
AT2/0-2/0
AT2/0-1/0
AT3/0-3/0
AT4/0-4/0
AT4/0-2/0
AT250-250
AT300-300
AT350-350
AT350-4/0
AT350-1/0
AT400-400
AT500-500
AT500-350
AT500-4/0
AT750-750
AT750-500
AT750-350
AT750-4/0
AT1000-1000
AT1000-750
AT1000-500
AT1000-350
TAP
2
1/0
2
2/0
1/0
3/0
4/0
2/0
250
300
350
4/0
1/0
400
500
350
4/0
750
500
350
4/0
1000
750
500
350
1500
TAPEREDTEE
CAT. NUMBER
ATT2-2
ATT1/0-1/0
ATT1/0-2
ATT2/0-2/0
ATT2/0-1/0
ATT3/0-3/0
ATT4/0-4/0
ATT4/0-2/0
ATT250-250
ATT300-300
ATT350-350
ATT350-4/0
ATT350-1/0
ATT400-400
ATT500-500
ATT500-350
ATT500-4/0
ATT750-750
ATT750-500
ATT750-350
ATT750-4/0
ATT1000-1000
ATT1000-750
ATT1000-500
ATT1000-350
ATT1500-1500
2
RUN L T
1/0
2/0
3/0
4/0
250
300
350
400
500
750
1000
1500
4-1/4
2-1/2
3
2-1/2
3
3-1/8
3
2-1/2
4
4
5-1/2
3-1/8
3
3
6
5-1/2
5-1/2
3-1/8
3-1/8
6
5-1/2
6
6-5/8
7-3/4
8
9
8
9-7/8
14
'AT' and 'ATT' series are warranted to meet or exceed Class A requirements of ANSI C119.4.
FOR TIN PLATING ADD SUFFIX ‘TN’ TO CATALOG NUMBER, e.g. AT2-2TN.
FOR OTHER SIZES AVAILABLE, PLEASE CONSULT THE FACTORY.
Aluminum Tapered Tees
Low VoltageAluminum Tees
Ends tapered for high voltage primaryapplications to 69 KV.
Available in may run and tap sizes.
Made of high conductivity aluminum.
Accepts both aluminum and copperconductors.
Connector bores are coated with oxideinhibiting compound.
Marked with catalog numbers, conductorsizes and die references.
Designed for general application.
Available in many run and tap sizes.
Made of high conductivity aluminum.
Accepts both aluminum and copper conductors.
Connector bores are coated with oxide inhibiting compound.
Marked with catalog numbers, conductorsizes and die references.
•
•••
•
•
••••
•
•
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
AL
/ CU
Co
mp
ression
Tee Co
nn
ectors
73
RUN TAPTapered TeeCat. Number
Compression TeeCat. Number L T
6421
1/06421
1/02/021
1/02/04/021
1/02/04/02501/02/04/0
TT1/0-6TT1/0-4TT1/0-2TT1/0-1
TT1/0-1/0TT2/0-6TT2/0-4TT2/0-2TT2/0-1
TT2/0-1/0TT2/0-2/0TT4/0-2TT4/0-1
TT4/0-1/0TT4/0-2/0TT4/0-4/0TT250-2TT250-1
TT250-1/0TT250-2/0TT250-4/0TT250-250TT350-1/0TT350-2/0TT350-4/0TT350-350TT400-1/0TT400-2/0TT400-4/0TT400-250TT400-300TT400-350TT400-400TT500-1/0TT500-2/0TT500-4/0TT500-250TT500-350TT500-400TT500-500TT600-2/0TT600-4/0TT600-350TT600-500TT600-600TT750-350TT750-500TT750-750
TT1000-500TT1000-1000
3501/02/04/02503003504001/02/04/02503504005002/04/0350500600350500750500
1000
1/0
2/0
4/0
250
350
3-3/43-13/163-7/8
3-15/164
3-29/323-31/324-1/324-3/32
4-5/32
4-3/16
4-1/44-5/164-7/16
4-1/4
4-5/164-3/84-1/2
4-9/16
5-37/64
5-23/32
1-1/2
1-5/8
1-3/4
2-3/16
400
500
600
750
1000
5-29/32
5-21/32
5-25/325-27/325-29/325-31/326-1/32
6-23/64
6-15/326-17/326-21/32
6-23/32
7-3/167-7/167-9/16
7-11/16
7-7/8
9-1/2
2-3/8
2-19/32
3-3/32
3-3/8
4
Copper Tapered Tees
End tapered for high voltage applications to 69KV.
Made from pure electrolytic gradeseamless copper tubing.
Hot tin dipped for corrosive resistance.
Available in a variety of run and tap sizes.
For other sizes available, consult factory.
•
•
••
•
•
•••
CopperCompression Tees
Made from pure electrolytic gradeseamless copper tubing.
Hot tin dipped for corrosion resistance.
Available in a variety of run and tap sizes.
For other sizes available, consult factory.
1/0T61/0T41/0T21/0T1
1/0T1/02/0T62/0T42/0T22/0T1
2/0T1/02/0T2/04/0T24/0T1
4/0T1/04/0T2/04/0T4/0250T2250T1
250T1/0250T2/0250T4/0250T250350T1/0350T2/0350T4/0350T350400T1/0400T2/0400T4/0400T250400T300400T350400T400500T1/0500T2/0500T4/0500T250500T350500T400550T500600T2/0600T4/0600T350600T500600T600750T350750T500750T750
1000T5001000T1000
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
74
Copper Clamp TypeTee Connectors
Provides permanent compression on thetap while allowing future disconnectability.
Constructed of cast copper and seamlesscopper tubing.
Supplied tin plated for corrosion resistance.
•
•
•
RUN
750 MCM750 MCM750 MCM750 MCM750 MCM750 MCM1000 MCM1000 MCM1000 MCM1000 MCM1000 MCM1000 MCM1000 MCM1500 MCM1500 MCM1500 MCM1500 MCM1500 MCM1500 MCM1500 MCM1500 MCM
TAP
2/0 STR4/0 STR
250 MCM350 MCM500 MCM750 MCM2/0 STR4/0 STR
250 MCM350 MCM500 MCM750 MCM1000 MCM
2/0 STR4/0 STR
250 MCM350 MCM500 MCM750 MCM1000 MCM1500 MCM
B
1-1/2"1-5/8"1-5/8"
2"2-1/4"2-7/8"1-1/2"1-5/8"1-5/8"
2"2-1/4"2-7/8"
3"1-1/2"1-5/8"1-5/8"
2"2-1/4"2-7/8"
3"3-3/16"
L
4-7/8"5"5"
5-3/8"5-5/8"6-1/4"4-7/8"
5"5"
5-3/8"5-5/8"6-1/4"6-3/8"4-7/8"
5"5"
5-3/8"5-5/8"6-1/4"6-3/8"6-7/8"
CATALOGNUMBER
2131-12131-22131-32131-42131-52131-62131-72131-82131-92131-102131-112131-122131-132131-142131-152131-162131-172131-182131-192131-202131-21
CONDUCTOR SIZE DIMENSIONS IN INCHES
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
75
NEMA Lug Tee Tapsfor Cable Buses
Type 'NLT' for copper mains and 'ANLT' foraluminum mains, accommodate all sizes ofstandard NEMA drilled compression lugs.
Provides connect and disconnect points onring bus or cable ring bus applications.
Protective insulating covers are available.
•
•
•
MAIN CONDUCTOR
4/0 CU350 MCM CU500 MCM CU500 MCM CU750 MCM CU750 MCM CU750 MCM AL750 MCM AL
1000 MCM CU1000 MCM CU1000 MCM AL1000 MCM AL
FIG. #
221212121212
INSULATINGBOOT NO.
--
RBL500
RBL750
RBL750A
RBL1000
--
WIDTH
1-1/2"1-1/2"1-1/2"1-1/2"1-3/4"1-3/4"2-1/2"2-1/2"1-3/4"1-3/4"2-1/2"2-1/2"
CATALOGNUMBER
NLTT-4/0NLTT-350NLT-500
NLTT-500NLT-750
NLTT-750ANLT-750
ANLTT-750NLT-1000
NLTT-1000ANLT-1000
ANLTT-1000
FOR SIZES NOT LISTED, PLEASE CONSULT THE FACTORY.
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
76
Meter SocketLugs“840”Common Die Series• For meter pan and general application.
• Entire conductor range installed with one die.
• Accept both aluminum and copper conductors.*
• Made of high conductivity aluminum.
• Connector bores are coated with oxide inhibitingcompound.
• Marked with catalog numbers, conductor sizesand die references.
“SAKM” series lugs are warranted to meet or exceed Class A requirements of ANSI C119.4.
FOR TIN PLATING ADD SUFFIX ‘TN’ TO CATALOG NUMBER, e.g. SAKM-6-48TN.
* 350 MCM SIZE ACCEPTS ALUMINUM CONDUCTOR ONLY.
840TX, 76
24911 A
CONDUCTORS - ALUMINUM OR COPPER 1/2 BOLT 3/8 BOLTINSTALLINGCATALOG CATALOG
CONCENTRIC COMPRESSED COMPACT SOLID NUMBER NUMBER DIES
6 6 6 - SAKM-6-48 SAKM-6-38
4 4 4 - SAKM-4-48 SAKM-4-38
2 2 2 & 1 1 SAKM-2-48 SAKM-2-38
1 1 1/0 1/0 SAKM-1-48 SAKM-1-38
1/0 1/0 2/0 2/0 SAKM-1/0-48 SAKM-1/0-38
2/0 2/0 3/0 3/0 SAKM-2/0-48 SAKM-2/0-38
3/0 3/0 4/0 - SAKM-3/0-48 SAKM-3/0-38
4/0 4/0 250 - SAKM-4/0-48 SAKM-4/0-38
250 250 300 - SAKM-250-48 SAKM-250-38
300 300 350 - SAKM-300-48 SAKM-300-38
350 350 - - SAKM-350-48* SAKM-350-38*
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
Meter S
ocket L
ug
s
77
Right Handand Left HandMeter Socket Lugs• For application in meter pans and in other metal
enclosed gear to convenience wiring where clearancesare minimal.
• Made of high conductivity aluminum and tin plated.
• Accepts aluminum and copper conductors.
• Connector bores are coated with oxide inhibitingcompound.
• Marked with catalog numbers, conductor sizesand die references.
NOTE: LEFT AND RIGHT NEMA DRILLED LUGS ARE AVAILABLE, SUBSTITUTE -NLTN FOR -48LTN, e.g. AL 350 NLTN;NEMA DRILLING IS 2-9/16" HOLES ON 1-3/4" CENTERS.
“AL-LTN” and “AL-RTN” series lugs are warranted to meet or exceed Class A requirements of ANSI C119.4.
WIRE SIZE CATALOG NUMBER INSTALLING CATALOG NUMBERCONCENTRIC
COMPRESSEDCOMPACT
LEFT HAND LUG DIESB L W
RIGHT HAND LUG
1/0 1/0 2/0 AL1/0 - 48 LTN 5/8, BG, TU2-11/16
AL1/0 - 48 RTN
2/0 2/0 - AL2/0 - 48 LTN 5/8-1, 297, TWTY 1-3/8 1-3/8 AL2/0 - 48 RTN
3/0 3/0 - AL3/0 - 48 LTN 737, 467 3-3/4 AL3/0 - 48 RTN
4/0 4/0 - AL4/0 - 48 LTN 840, 298, TX 1-1/2 41-3/4
AL4/0 - 48 RTN
250 250 300 AL250 - 48 LTN 840, 324, TX 4-1/8 AL250 - 48 RTN
300 300 350 AL300 - 48 LTN 1, 470, TH 1-5/84-3/8
AL300 - 48 RTN
350 350400
AL350 - 48 LTN 1-1/8, 299, 961-5/8
AL350 - 48 RTN
400 400 AL400 - 48 LTN 1-1/8, 472, 962-1/2 5-3/4
AL400 - 48 RTN
500 500 500 AL500 - 48 LTN 1-5/16, 300, 106A AL500 - 48 RTN
700 - 750 800 800 AL750 - 48 LTN 1-1/2, 301, 140H 3-1/4 6-3/8 3-1/2 AL750 - 48 RTN
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
WIRE STRANDED CATALOG INSTALLINGSIZE CU PIN NUMBER DIES B C D L
6 #8 BMS-6C
4 #6 BMS-4C
2 #4 BMS-2C 2-1/4
1 #3 BMS-1C 1 2-3/8
1/0 #2 BMS-1/0C
2/0 #1 BMS-2/0C
3/0 1/0 BMS-3/0C
4/0 2/0 BMS-4/0C
250 3/0 BMS-250C 1-15/16 1-1/2 3-7/16
300 BMS-300C
350 BMS-350C
400 250 BMS-400C
500 BMS-500C
600 BMS-600C 4-1/2
750 500 BMS-750C 2 4-5/8
78
StrandedBi-MetallicPin Terminals• For application in meter pans and in other metal
enclosed gear to convenience wiring whereclearances are minimal.
• Tin plated stranded copper pin.
• Connector bores are coated with oxide inhibitingcompound.
• Marked with catalog numbers, conductor sizes anddie references.
• Supplied with EPDM insulating cover.
2-1/815A, 115H,318, 1-5/16
1-1/2, 608,125H
1-13/16 2-5/8
1-3/8
13A, 96,655, 1-1/8
840, 249,TX, 76
1-1/4
15/8, BG,TU, 52
1-7/84
3-11/161-5/82-1/16
1-1/4
1-3/8
7/82-1/8
1-5/8
1-13/16
1-1/4
1-3/8
2-7/8
3-3/16
4/0
350
TO ORDER STRANDED BI-METALLIC PIN TERMINALSWITHOUT INSULATING COVER, DELETE SUFFIX "C"FROM CATALOG NUMBER, e.g. BMS-6.
Listed
E 73859
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
Multi-R
ange TakingC
onnectors
79
Multi-Range TakingLugs and Pin Terminals
Lugs and Stacking LugsMade from high conductivity aluminum and tin plated.
Connector bores coated with oxide inhibiting compound.
Marked with catalog numbers and conductor sizes.
•••
CONDUCTOR RANGEALUM. OR COPPER
CATALOGNUMBER
AL1/0-48TNAL1/0-NTN
ASL1/0-NTNAL4/0-48TNAL4/0-NTN
ASL4/0-NTNAL300-48TNAL300-NTNAASL300-N
SAB500-48TNSAB500-NTNAASL500-N
AL750N-608-TN
TOOL FIGURE
VC-5/VC-6
1231231231232
BOLTSIZE
1/2
B
1-1/2
2
2-1/4
2-1/22-1/42-1/23-3/4
L P1-5/163-1/43-1/81-3/83-3/83-1/8
1-5/163-9/163-1/81-1/23-1/82-7/83-3/8
6 STR - 1/0 STR
2 STR - 4/0 STR
1/0 STR - 300 MCM
4/0 STR - 500 MCM
4/0 STR - 750 MCM
3-3/16
5-1/4
3-9/16
6
4
6-9/16
4-9/166-3/86-5/88-1/4
VC-6
VC-8
•
•
TO ORDER A STUD SIZE NOT SPECIFIED WITH A TERMINAL LUG ON THIS SHEET, CHANGE THE LAST TWO DIGITS FROM 48(DESIGNATING 1/2” STUD) TO 58 (FOR 5/8” STUD).
Pin TerminalsMade from pure electrolytic aluminum and soft drawntinned solid copper wire.Offer bi-metallic transitions from all alumimum, ACSR, and aluminum alloy conductors to copper clamp type equipment bushings.
CONDUCTOR SIZEDECIMAL RANGE
MIN. O.D. MAX. O.D.10 SOL - 1/0 ACSR4 SOL - 4/0 ACSR
2/0 STR - 336.4 18/1 ACSR
CATALOGNUMBER TOOL CU. PIN P
FOR TIN PLATING, ADD SUFFIX ‘TN’ TO CATALOG NUMBER.
.102
.204
.414
.398
.563
.684
PTA-1/0PTA-4/0PTA-350
VC-5/6
VC-6
22/04/0
6
12 Southland Road, Ormond Beach, FL 32174 • Phone: 386-677-9110 • Fax: 386.673.5497 • E-mail: [email protected] • www.homac.com
80
Multi-Range TakingSplices
MINIMUM TENSIONMade from high conductivity aluminum.Solid center stop assures proper cable insertion.Accept both aluminum and copper conductors.Connector bores are coated with oxide inhibiting compoundand capped.Marked with catalog number and conductor sizes.
•••••
CONDUCTOR SIZEDECIMAL RANGE
MIN. O.D. MAX. O.D.CATALOGNUMBER TOOL LSGAC 1/0SNG 00
SGAC 3/0SGAC 250SGAC 350SGAC 500
SGAC 8650SGAC 8800
FOR TIN PLATING, ADD SUFFIX ‘TN’ TO CATALOG NUMBER, e.g. SGAC1/0TN.
10 SOL - 1/0 ACSR
8 SOL - 3/0 STR4 SOL - 266.8 MCM - 4/0 ACSR2/0 STR - 350 MCM - 336.4 18/14/0 STR - 500 MCM -477 18/1
350 MCM STR - 636 36/1 400 MCM CU MAX.397.5 MCM STR - 795 36/1 500 MCM CU MAX.
VC-5/VC-6
VC-6
VC-8
24-1/4
34
5
8-7/810-5/8
.102
.128
.204
.414
.522
.681
.724
.398
.470
.593
.684
.814
.9401.040
FULL TENSIONMade from high conductivity aluminum.Solid center stop assures proper cable insertion.Accept both aluminum and copper conductors.Connector bores are coated with oxide inhibiting compoundand capped.Marked with catalog number and conductor sizes.
•••••
CONDUCTOR SIZEDECIMAL RANGE
MIN. O.D. MAX. O.D.CATALOGNUMBER TOOL L
U2A9AAC 4/0 FT.AAC 350 FT.AAC 500 FT.
VC-5/VC-6
VC-6
4 STR - 1/0 STR ALUM1/0 STR - 4/0 STR ALUM
4/0 STR - 350 MCM ALUM - 336.4 18/1336.4 STR - 500 MCM ALUM
.232
.368
.522
.666
.368
.522
.681
.795
6-1/48
9-1/212-1/2
CONTINUED NEXT PAGE
DECIMAL RANGE CATALOGCONDUCTOR SIZE
MIN. O.D. MAX. O.D. NUMBERTOOL B L
4 STR - 2 STR ALUM, 4 (6/1) 2 (7/1) ACSR6 SOL - 4 SOL CU, 6 STR - 2 STR CU
2 STR - 1/0 (6/1) ACSR .292 .398 ACSR-1/0 FT. 8-3/8 17
2 STR - 2/0 STR ALUM, 2 (6/1)-2/0 (6/1) ACSR2 STR - 1/0 STR CU
1/0 STR - 4/0 STR ALUM1/0(6/1) - 4/0(6/1)ACSR, 1/0 STR - 3/0 STR CU
4/0 - 397.5 STR ALUM, 4/0(6/1) - 397 (18/1)ACSRSINGLE CORE ONLY, 3/0 STR - 4/0 STR CU
DECIMAL RANGE CATALOGCONDUCTOR SIZE
MIN. O.D. MAX. O.D. NUMBERTOOL B L
2 STR - 2/0ACSR .292 .447 SKAC-2/0 3-1/8 6-1/2
1/0 STR - 4/0ACSR .368 .563 SKAC-4/0
4/0 STR - 477 (18/1)ACSR .522 .814 SKAC-500 VC-6
300 MCM - 477 (26/7)ACSR .629 .858 SKAC-600 5-7/16 11-1/8
556.5 MCM - 636 (36/1)ACSR .858 .930 SKAC-700
700 MCM - 795 (36/1)ACSR .964 1.040 SKAC-800
81
• Made of high conductivity aluminum.
• Solid center stop assures proper cable insertion.
• Accepts both aluminum and copper conductors.
• Connector bores are coated with oxide inhibiting compound and capped.
• Marked with a catalog number, conductor sizes.
8
FOR TIN PLATING ADD SUFFIX ‘TN’ TO CATALOG NUMBER.
VC-5/VC-6
3-7/8
6-5/16 12-7/8VC-8
• Made of high conductivity aluminum.
• Solid center stop assures proper cable insertion.
• Accepts both aluminum and copper conductors.
• Connector bores are coated with oxide inhibiting compoundand capped.
• Marked with a catalog number, conductor sizes.
PARTIAL TENSION
FULL TENSION
VC-6
ACSR-2 FT.
ACSR-2/0 FT.
ACSR-4/0 FT.
ACSR-397.5 FT.
.325.162 7 14-1/4
.447.292
.563
.743
.368
.464
9-1/8
9-7/8
18-1/2
20
11-3/8 23
VC-5/VC-6
FOR TIN PLATING ADD SUFFIX ‘TN’ TO CATALOG NUMBER.
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
82
InsulatedPinTerminalsAluminum Cableto Copper Stud
3
15/16
1 7/8
4
2 1/2
2
5/8-1, 297, 245
TWTY. 5/8 GOLD
TX, 76
249, 840, 11A
TU, 52, BG
243, 5/8, 8A
RU5U4
RU5U2
RU5U10
RG5U10
RG5U20
RX5U30
RX5U40
RX5U336
2
2
1/0
1/0
2/0
4/0
44
2
1/0
1/0
2/0
3/0
4/0
336.4 18/1
4
2
1/0
1/0
2/0
3/0
4/0
300 - 350
BPINSTALLING
DIESCATALOGNUMBER
SOLIDCU PINACSRALUM. STR.
CONDUCTOR SIZE
1 3/4
“Flood-Seal” Insulated Pin Terminals are fabricated from pureelectrolytic aluminum and soft drawn tinned copper wire.
600V “Flood-Seal” covers are provided to ensure a watertight sealon the pin as well as around the aluminum cable insulation.
Designed for use on aluminum secondary conductors to copperclamp type bushings.
Marked with die reference and filled with oxide inhibitor.
•
•
•
•
“Flood-Seal”®
“Flood-Seal” INSULATORS ONLY
L2CATALOGNUMBER
CONDUCTOR SIZEACSRALUM. STR.
4 - 1/0
1/0 & 2/0
3/0 - 336.4
4 - 1/0
1/0 & 2/0
3/0 - 336.4
RU5
RG5
RX5
3 13/16
5 11/16
6 7/16
Pin Terminals are available in other wirebarrel diameters suitable for non-listedtooling(dies).
Please consult factory for special dierequirements.
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
Overh
ead Tran
sform
erC
on
necto
rs
SOL.642-642
STR.8
5 & 63 & 41 & 2
85 & 63 & 41 & 21/01/02/03/04/0
250 - 266.8300-350
ACSR-642-642
1/01/02/03/04/0
266.8336.4 (18/1)
ALUM. STR.266.8 & 300
336.4 & 350
397.7 & 400
447 & 500 & 600CPT
500 & 556.5
600
600 & 636
700 & 750
795 & 800
954 & 1000
ACSR266.8, 18/1266.8, 26/7336.4, 18/1336.4, 26/7397.5, 18/1397.5, 47726/7, 18/1477, 26/7
556.5, 18/1-
556.5, 63636/1, 26/7636, 26/7
715.5, 26/7795, 36/1795, 26.7954, 45/7
SOLIDCU PIN
.460
.562
.750
.875
P
4
5
6
CATALOGNUMBERPTB-300
PTB-350
PTB-400
PTM-500
PTM-556
PTL-600
PTL-636
PTL-750
PTL-800
PTL-1000
INSTALLING DIES*
96, 472,705, 1-1/8-1
106A, 300,426, 1-5/16
317
140H, 301,724, 1-1/2
CATALOGNUMBER
Q5U8Q5U6Q5U4Q5U2U5U8U5U6U5U4U5U2U5U10X5U10X5U20X5U30X5U40X5U266X5U336
INSTALLINGDIES
1/2, 163,TQ, 6A*
5/8, G,BG,
TU, 8A*
840, WK840,249, TX, 11A*
SOLIDCU PIN
#4 (204)
#2 (.257)
1/0 (.325)
2/0 (.365)3/0 (.410)4/0 (.460)
P
2
2-1/2
3
3-1/24
CONDUCTOR SIZE
CONDUCTOR SIZE
ALUMINUM
83
PIN LENGTHS, OTHER THAN THESTANDARDS LISTED ARE AVAILABLE:TO SPECIFY NON-STANDARD PINLENGTHS, SUFFIX THE LENGTH (P)TO CAT.# E.G. FOR A 6" LONG PINFOR 300 MCM WIRE. SPECIFYPTB300-6.
*PIN TERMINALS ARE AVAILABLE INOTHER WIRE BARREL DIAMETERSSUITABLE FOR NON-LISTED TOOLING(DIES). PLEASE CONSULT FACTORYFOR SPECIAL DIE REQUIREMENTS.
* WHEN USING EE1 DIES,SPACE COMPRESSIONS1/8” APART.
Pin TerminalsCompression Type
Pin TerminalsPT Series
Pin Terminals - Aluminum Cable to Copper StudWide application in connecting aluminum andACSR to copper alloy equipment clamps, designedfor use with copper.
Eliminate cold flow problems of aluminumconductor in copper clamps.
Pin secured to aluminum body by heavy knurlingunder factory compression.
After installation of aluminum conductor in the
terminal barrel, the pin is installed in the equipmentclamp. Annealed, tin plated copper pin is easilybent to aid cable training.
Prefilled with oxide inhibitor compound.
Marked with wire size, installing dies andcompression locations.
Metal sealant protects pin/body interface frommoisture intrusion.
•
•
•
•
••
•
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
84
Set Screw BarTransformer ConnectorsABP SeriesWith Copper Stud Mounted
Designed with factory mounted 90° angle studs for installation in pole typetransformers with secondary eyebolt connections.
High strength aluminum alloy - constant bolting pressure onconductors is maintained.
Maximum conductor contact pressure - screws designed foroptimum electrical connection.
Testing - meets or exceeds ANSI C119.4 Class ‘A’ requirements.
Options - Please consult the factory for special applications.
•
•
•
••
CABLERANGE
6-250
6-350
CABLERANGE
2-500
1/0-750
STUDSIZE
1/2"x4"
1/2"x4"
STUDSIZE
3/4"x
4-1/2"
3/4"x
4-1/2"
OUTLETS
23456782345678
OUTLETS
23456782345678
CATALOGNUMBER
ABP240ABP340ABP440ABP540ABP640ABP740ABP840ABP2350ABP3350ABP4350ABP5350ABP6350ABP7350ABP8350
CATALOGNUMBER
ABP2500ABP3500ABP4500ABP5500ABP6500ABP7500ABP8500ABP2750ABP3750ABP4750ABP5750ABP6750ABP7750ABP8750
LENGTH
2-5/83-3/84-5/324-5/165-3/46-1/27-9/323-3/164-1/8
55-15/166-13/167-3/48-5/8
LENGTH
3-5/84-5/85-5/86-5/87-5/88-5/89-5/84-1/45-5/8
6-15/168-9/329-5/8
10-61/6412-5/16
Specialties Available
CONSULT FACTORY FOR INSULATING BOOTS.
CABLERANGE
6-250
STUDSIZE
1/2"
CATALOGNUMBER
ABP3168
OUTLETS
4
LENGTH
4-1/4"
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
85
Homac introduces 2 new Transformer Bushing Pads, theTPH-2N and TPH-4N. They replace the transformer eyebolt and are disigned to sit flush and interlock with thebushing. The TPH-2N accommodates up to 2 terminalsthat can be bolted to either side of the pad, the THP-4Naccommodates up to 4 terminals. Other configurationsare available.
The new threaded bushing pads are cast in high gradebronze, precision machined and tin plated.
TPH-2N
TPH-4N
TransformerBushing Pads
NEW!
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
CONDUCTOR SIZE SOLID CATALOG SHROUD INSTALLINGALUM STRANDED ACSR CU PIN NUMBER I.D. DIES† P B STYLE
6 6.204
PTSG-6 .40052 2
4 4 PTSG-4 .450 TU, BG, 8A 2 1-7/8
2 -1 2 PTSG-2 .6045/8, 243
11/0 1/0 .258 PTSG-1/0
.6402-1/4
1/0 1/0 PTSK-1/0
840, 11A2/0 2/0.324
PTSK-2/0
.75076, TX 1-3/4
3/0 3/0 PTSK-3/0 249 4
4/0 4/0 .364 PTSK-4/0 2
336.4-350266.6-26/7
.460 PTSB-350 .9371-1/8-1, 299,
3-1/8366.4-18/1 655, 96, 13A
600-636556.5-26/7
.562 PTSL-636 1.1251-1/2, 301
6 3-3/8636-36/1 724, 140H
86
Shrouded Pin Terminals• Rainshield protection for insulated cable installed in exposed areas.
• Fabricated from pure electrolytic aluminum and soft drawn solid tinned copper wire.
• Designed for use on aluminum secondary conductors to copper clamp type bushings.
• Marked with die reference and filled with oxide inhibitor compound.
• Metal sealant protects pin/body interface from moisture intrusion.
PIN LENGTHS, OTHER THAN THE STANDARDS LISTED ABOVE ARE AVAILABLE: TO SPECIFY NON-STANDARD PINLENGTHS, SUFFIX THE LENGTH (P) TO CAT. NO. e.g. FOR A 6" LONG PIN FOR 350 MCM WIRE, SPECIFY PTSB-350-6.
† PIN TERMINALS ARE AVAILABLE IN OTHER WIRE BARREL DIAMETERS SUITABLE FOR NON-LISTED TOOLING (DIES)PLEASE CONSULT FACTORY FOR SPECIAL DIE REQUIREMENTS.
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
CONDUCTOR SIZES CATALOG SHROUD COMP.STR ACSR SOLID COMPACT NUMBER I.D. DIE SIZE L STYLE
5/8 COMPRESSION DIE SERIES
10 - - - RSG10-48 .307
6 6 - - RSG6-48 .400 3-3/8 2
4 4 2 4 RSG4-48 .450
2 & 1 2 - 1 RSG2-48 .6353-5/8 1
1/0 1/0 - 2/0 RSG1/0-48 .640
840 COMPRESSION DIE SERIES
1/0 1/0 - 2/0 RSK1/0-48 .640
2/0 2/0 - 3/0 RSK2/0-48
3/0 3/0 - 4/0 RSK3/0-48 .750 3-3/4 2
4/0 4/0 - 4/0 RSK4/0-48
250 266(18-1) - 336 RSK250-48 .812
350 336(18-1) - - RSK350-48 .937 4-7/16 1
1-1/8 COMPRESSION DIE SERIES
300 266(18-1) - 350 RSB300-48.927 4-5/8 2
350 336(18-1) - - RSB350-48
87
Shrouded Aluminum LugsCommon Die Series• Rainshield protection for insulated cables installed in exposed areas.
• Entire range installed with 3 die sizes.
• Made from high conductivity aluminum.
• Accept both aluminum and copper conductors.
• Connector bores are coated with oxide inhibiting compound.
• Marked with catalog numbers, conductor sizes and die references.
TO ORDER WITH HARDWARE AS KITS, ADD "TMH" TO CATALOG NUMBER; i.e. RSK250-48TMH.
"RS" SERIES ARE WARRANTED TO MEET OR EXCEED CLASS A REQUIREMENTS OF ANSI C119.4.
TO ORDER A TERMINAL LUG FOR 3/8" STUD, CHANGE THE LAST TWO DIGITS FROM 48 (designating 1/2" stud)TO 38 (for 3/8" stud).
FOR TIN PLATING, ADD SUFFIX 'TN' TO CATALOG NUMBER, e.g. RSG4-48TN.
5/8, 8A
243
TU, 52, BG
840, 11A
249
76, TX
1-1/8, 13A,96
299, 655
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
We’re your “No Hassle” Source for a completeline of Fire-On and Bolted Wedge Taps.
Homac’s NEW Power Tap® Series.
Homac Mfg. CompanyOrmond Beach, FL 32174 USA
12 SOUTHLAND RD. ORMOND BEACH, FL 32174TELEPHONE 904-677-9110 FAX 904-673-5497
�� �
� �
� �� � � � � �
�ISO9001
88
“RUS Accepted”Fire-On Power Tap Series are
Power Tap® Selection ChartCATALOGNUMBER
CATALOGNUMBER
CATALOGNUMBER
WIRECOMBINATIONS
WIRECOMBINATIONS
WIRECOMBINATIONS
SMALL TAPSUSE SHELL# PT- RED
350 MCM TAPSUSE SHELL# PT- BLUE
PT-1001PT-1002PT-1003PT-1004PT-1005PT-1006PT-1007PT-1008PT-1009
PT-35000PT-35001PT-35002PT-35003PT-35004PT-35005PT-35006PT-35007
1/0-22-4, 1/0-62-2, 1/0-46-6, 4-64-4, 2-6
8-81/0-82-8
4-8, 6-8
350 to 6350 to 4350 to 2
350 to 1/0350 to 2/0350 to 3/0350 to 4/0350 to 350
MEDIUM TAPSUSE SHELL# PT- BLUE
336 - 477- 556 TAPSUSE SHELL# PT- YELLOW
1033.5 MCM TAPSUSE SHELL# PT- YELLOW
1192 MCM TAPSUSE SHELL# PT- YELLOW
PT-4001PT-4002PT-4003PT-4004PT-4005PT-4006PT-4007PT-4008PT-4009PT-4010PT-4011
PT-33601PT-33602PT-33603PT-33604PT-33605PT-33606PT-33607PT-33608PT-33609
PT-47701PT-47702PT-47703
PT-55601PT-55602
PT-55603
PT-55604
PT-55605
PT-55606
PT-55607
PT-55608
PT-55609PT-55611PT-55612
1/0-1/0, 2/0-2, 1/0-22/0-2/0, 3/0-1/0, 4/0-2
3/0-6, 2/0-62/0-4, 3/0-4
2/0-1/0, 3/0-24/0-44/0-4
3/0-2/0, 4/0-1/03/0-3/0, 4/0-2/0
4/0-3/04/0-4/0
336.4 to 336.4336.4 to 266.8336.4 to 4/0336.4 to 3/0336.4 to 2/0336.4 to 1/0336.4 to 2336.4 to 4336.4 to 6
477 to 2, 3477 to 4, 5477 to 6
556.5 to 477, 556.5477 to 477
556.5 to 336.4477 to 336.4
556.5 to 266.8477 to 266.8
556.5 to 3/0, 4/0477 to 4/0
556.5 to 2/0477 to 3/0
556.5 to 1/0477 to 2/0556.5 to 1477 to 1/0556.5 to 2
556.5 to 2, 3556.5 to 4, 5556.5 to 6
266 TAPSUSE SHELL# PT- BLUE
PT-26601PT-26602PT-26603PT-26604PT-26605PT-26606PT-26607PT-26609
266.8 to 6266.8 to 4266.8 to 2
266.8 to 1/0266.8 to 2/0266.8 to 3/0266.8 to 4/0
266.8 to 266.8
TYPE II TAPSUSE SHELL# PT- WHITE
795 MCM TAPSUSE SHELL# PT- YELLOW
PT-1010PT-1011PT-1012PT-1013PT-1014PT-1015
1/0 to 22-2 & 1/0-42-4 & 1/0-64-4 & 2-66-6 & 4-6
8 to 8
STREET LIGHT TAPSUSE SHELL# PT- RED
POWER TAP SHELLSCOLOR CATALOG NO.
PT-1020PT-1021PT-1022PT-1023PT-1024
REDWHITEBLUE
YELLOW
PT-79500PT-79501PT-79502PT-79503PT-79504PT-79505PT-79506PT-79507PT-79508PT-79509PT-79510PT-79511PT-79512PT-79513PT-79514
PT-103300PT-103301PT-103302PT-103303PT-103304PT-103305PT-103306PT-103307PT-103308PT-103309PT-103310PT-103311PT-103312PT-103313PT-103314PT- 103315PT-103316
PT-119200PT-119201PT-119202PT-119203PT-119204PT-119205PT-119206PT-119207PT-119208PT-119209PT-119210PT-119211PT-119212PT-119213PT-119214PT-119215PT-119216PT-119217
1/0 to 10-12-142 to 10-12-144 to 10-12-146 to 10-12-148 to 10-12-14
PT-REDPT-WHITEPT-BLUE
PT-YELLOW
795 to 795795 to 715795 to 636
795 to 556.5795 to 477
795 to 397.5795 to 336.4795 to 266.4795 to 4/0795 to 3/0795 to 2/0795 to 1/0795 to 2795 to 4795 to 6
1033.5 to 1033.51033.5 to 9541033.5 to 795
1033.5 to 715.51033.5 to 636
1033.5 to 556.51033.5 to 477
1033.5 to 397.51033.5 to 336.41033.5 to 266.81033.5 to 4/01033.5 to 3/01033.5 to 2/01033.5 to 1/01033.5 to 21033.5 to 41033.5 to 6
1192.5 to 1192.51192.5 to 1033.5
1192.5 to 9541192.5 to 795
1192.5 to 715.51192.5 to 636
1192.5 to 556.51192.5 to 477
1192.5 to 397.51192.5 to 336.41192.5 to 266.81192.5 to 4/01192.5 to 3/01192.5 to 2/01192.5 to 1/01192.5 to 21192.5 to 41192.5 to 6
For a Kit consisting of both aConnector and the correct PowerTap Shell, add -K to the PartNumber (ie PT-33601-K).
89
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
BOL TBOL TAPAP®
make the RIGHTconnection!
FAST & EASY - saves time andmoney!
NO SPECIAL TOOLS AREREQUIRED - only hammer andwrench needed.
REMOVABLE & REUSABLE -reduces scrap material.
STIRRUP CONNECTORS are alsoavailable, consult factory.
WIDE CONDUCTOR RANGE -reduces inventory.
VISUAL INSPECTION - insuresproper installation.
90
WIRE SIZE AVAILABLE
RUN TAP SERIES
954 AA795636556.5 ACSR
556.5 AA477397.5350336.4266.8 ACSR
954 AA795636556.5 ACSR
556.5 AA477397.5350336.4266.8 ACSR
THROUGH#6
5000
4000
New!
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
BOL TAP ®
954
AA
795
26/7
795
45/7
795
AA
636
26/7
605
24/7
653
18/3
556
26/7
636
AA
750
CP
T55
6 A
A47
7 26
/747
7 A
A39
7 26
/750
0 C
PT
397
AA
336
26/7
350
AA
CU
336
18/1
336
AA
266
26/7
300
CU
266
AA
250
AA
CU
4/0
6/1
250
CP
R4/
0 A
A C
U3/
0 6/
14/
0 C
PT
3/0
AA
CU
4/0
SO
LID
2/0
4/3
AW
AC
2/0
6/1
2/0
AA
CU
3/0
SO
LID
1/0
6/1
1/0
AA
CU
2/0
SO
LID
1/0
SO
LID
#2 6
/1#2
AA
CU
#2 S
OL
ID#4
6/1
#4 A
A C
U#4
SO
LID
#6 6
/1#6
AA
CU
954 AA795 (26/7)795 (45/7)795 STR
636 (26/7)605 (24/7)653 (18/3)556 (28/7)636 STR750 CPT
556 STR477 (26/7)477 STR
397 (26/7)500 CPT397 STR
336 (26/7)350 AL CU336 (18/1)336 STR
266.8 (26/7)
CATALOG NUMBERS1 A-4025 4 A-4040 7 A-4055 10 A-5035 13 A-5050 16 A-5065 19 A-50802 A-4030 5 A-4045 8 A-4060 11 A-5040 14 A-5055 17 A-5070 20 A-5085 3 A-4035 6 A-4050 9 A-4065 12 A-5045 15 A-5060 18 A-5075 21 A-5090
MAINCONDUCTOR
12
12
12
11
11
11
11
10
10
10
3
3
2
2
2
2
2
1
1
1
1
12
12
12
11
11
11
11
10
10
10
3
3
2
2
2
2
2
1
1
1
1
14
14
13
13
12
12
12
12
12
12
4
4
4
4
4
3
3
3
3
3
2
14
14
13
1313
12
12
12
12
12
5
5
4
4
3
3
3
3
3
3
2
14
13
13
1312
12
12
12
12
11
4
4
4
3
3
3
3
2
2
2
2
14
14
13
13
13
12
12
12
12
12
5
5
4
4
4
3
3
3
3
3
3
14
14
14
1313
13
13
13
12
12
5
5
4
4
4
4
4
3
3
3
3
15
14
14
1313
12
12
12
12
12
5
5
4
4
4
3
3
3
3
3
3
15
14
14
1413
12
12
12
12
12
5
5
5
4
5
4
4
3
3
3
3
15
14
14
14
13
12
12
12
12
12
5
5
5
4
5
4
4
3
3
3
3
15
15
14
1414
13
13
13
13
13
6
6
5
5
4
4
4
4
4
4
3
15
15
14
14
13
12
12
13
13
13
5
5
5
5
5
4
4
4
3
3
3
15
15
14
1414
13
13
13
13
13
6
6
5
5
5
4
4
4
4
4
3
15
15
15
1414
13
13
13
13
13
6
6
5
5
5
4
4
4
4
4
4
15
15
15
1414
14
14
13
13
13
6
6
5
5
5
5
5
4
4
4
4
16
16
15
1414
14
14
14
14
14
6
6
6
5
6
5
5
4
4
4
4
16
16
15
15
14
14
14
14
14
14
6
6
6
6
6
5
5
5
4
4
4
16
16
15
15
14
14
14
14
14
14
6
6
6
6
6
5
5
5
4
4
4
16
16
16
15
15
15
15
14
14
14
6
6
6
6
6
5
5
5
5
5
4
16
16
16
15
15
15
15
14
14
14
7
7
6
6
6
6
6
5
5
5
5
17
17
16
1615
15
15
15
15
15
7
7
7
6
7
6
6
5
5
5
5
17
17
16
1615
15
15
15
15
15
7
7
7
7
7
6
6
6
6
6
17
17
16
1615
15
15
15
15
15
7
7
7
7
7
6
6
6
6
6
17
17
16
16
15
15
15
15
15
15
8
8
7
7
7
6
66
17
17
17
17
16
16
16
16
16
15
8
8
7
7
8
7
7
18
17
17
17
16
16
16
16
16
15
8
8
8
7
8
7
7
18
18
17
1716
16
16
16
16
16
8
8
8
8
8
18
18
17
17
16
16
16
16
16
16
9
9
8
8
18
18
18
17
17
16
16
16
16
16
9
9
8
19
19
18
18
17
17
17
17
17
17
9
9
19
19
18
1817
17
17
17
17
17
9
9
19
19
19
18
18
18
18
17
17
17
19
19
19
18
18
18
18
17
17
19
19
19
18
18
18
18
18
18
20
19
19
19
18
18
18
20
20
19
19
18
18
18
20
20
19
1919
20
20
20
19
21
21
20
21
21
21 13
13
12
12
11
11
11
11
11
11
3
3
3
3
3
2
2
1
1
1
1
13
12
12
12
11
11
11
11
10
10
3
3
2
2
2
2
2
1
1
1
1
13
13
12
12
11
11
11
11
11
11
3
3
3
3
3
2
2
1
1
1
1
13
13
12
1212
11
11
11
11
11
4
4
3
3
2
2
2
2
2
2
1
13
13
13
12
12
12
12
11
11
11
4
4
3
3
3
3
3
2
2
2
2
13
13
13
12
12
12
12
11
11
11
4
4
3
3
4
3
3
2
2
2
2
12 SOUTHLAND RD. ORMOND BEACH, FL 32174TELEPHONE 904-677-9110 FAX 904-673-5497
CONNECTORS CAN BE INSTALLED WITH HOT LINE TOOLS. FOR CONNECTOR WITH SHEAR HEAD BOLT, ADD “SH” TO CAT. NO. (ex. A-4060-SH).FOR CONNECTOR WITH STIRRUP, ADD “S” AND BAIL SIZE TO CAT. NO. (ex. A-4060-S10=1/0 BAIL).
TAPCONDUCTOR
USE CHART BELOW TO SELECT CATALOG NUMBER FROM ABOVE REFERENCE NUMBERS
91
WITHSTIRRUP
SELECTION CHARTBOL TAP ®
SEPSEPARABLEARABLEHomac’s NEW
92
TAP CONNECTOR• CONVENIENT• SAFE• EASY TO INSTALL• EASY TO REMOVE• REUSABLE• NO SPECIAL TOOLSOR DIES
• EVERTIGHT/ENERGY STORING
• NO BIRDCAGING
FOR ADDITIONAL SIZES - CONSULT FACTORY
WM COVER
Accommodates STR., ACSR, AAC andcompact wire.
Meet or exceed Class A requirements of ANSIC119.4 and CSA Standard C57.
Protective cover available for connectors up toand including WM 33640. Order catalog numberWM COVER.
WIRE SIZE CATALOGNUMBERRUN TAP
#2 - 41/0
1/0-21/0
3/0 - 2/03/0 - 2/03/0 - 2/0
4/04/0
336.4 - 266.8556.5 - 477556.4 - 477
#4 - 6#4 - 6
#21/0#21/0
3/0 - 2/01/0 - 2
4/0 - 2/04/0 - 2/04/0 - 2/0
477 - 266.8
WM 24WM 104WM 102WM 1010WM 302WM 3010WM 3030WM 4010WM 4040WM 33640WM 55640WM 556336 WITH STIRRUP
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
WIRE RANGE INSTALLATIONSTANDARD CONDUCTOR – ACSR-AAC DECIMAL EQUIVALENT INFORMATION
CATALOG GROOVE A GROOVE B GROOVE C GROOVE A GROOVE B GROOVE C NUMBER OF INDENTSNUMBER ACSR STR SOL MM2 ACSR STR SOL MM2 ACSR STR SOL MM2 MAX. MIN. MAX. MIN. MAX. MIN. HAND
UB214 2-6 2-6 1-6 35-10 8-14 7-14 6-2.5 .316 .162 .146 .064 3,2
OB2014 2/0-2 2/0-2 70-35 8-14 7-14 6-2.5 .460 .292 .146 .064 2OB33 4-6 3-4 4-6 10-25 4-6 3-4 4-6 10-25 .260 .260OB44 2-6 1-6 2-6 35-10 1-6 .332 .162 .332OB22 2-6 2-6 8-14 8-14 6-2.5 .325 .325 .162 .146 .064
4
OB101 1/0-3 2/0-2 2 50-25 2-6 2-6 35-10 .420 .258
HOB102 1/0-6 1/0-6 2-6 50-10 1-6 8-14 8-14 6-2.5 .332 .146 .064
OB103.398 .162
OB1010 1/0-4 2/0-4 2 50-25 1/0-4 2/0-4 2 50-25 .420 .232 .420 .2324
DB202 2/0-1 3/0-1/0 70-50 2-6 1-6 2-6 35-10 .470 .362 .332 .162 4DB2020 2/0-1 3/0-1/0 - 70-50 .470 .362 5DB404 2-6 1-6 2-6 35-10 .325 .162 4DB4020 4/0-3/0 4/0-3/0 120-95 2/0-2 3/0-1 70-35 .563 .464 .470 .316 6DB4040 4/0-3/0 4/0-3/0 120-95 .563 .464 7
NB500 477 18/1 477 18/1 500-4/0 240-120 .814 .5284/0 6/1 500-4/0 240-120 4/0 6/1 .814 .528
NB50040 477 18/1 4/0-2 4/0-2 120-35 2-6 2-6 2-6 35-10 .563 .292 .325 .1624/0 6/1
NB60020556.5
(24/7) 600-250 300-150 1/0 (7/1) 2/0-6 2-6 50-10 .893 .575 .419 .162266.8(18/1) 6 (6/1)
ZB954954 1000 954 1000 500-150 1.196 1.196 .586266.8 266.8 266.8 266.8
ZB95440795 750
500-150 336.4 350-4/0 185-120 .586 .741 .5284/02-6 2-6 35-10 1.140 .292 .162
ZB95410266.8 266.8
4/0-1/0 4/0-1/0 120-50 .563 .373
93
Aluminum H-Type Compression TapsFor service drop, secondary or primary tap and grounding installations on allcombinations of aluminum to aluminum, or aluminum to copper conductors.
Used to dead end aluminum, ACSR or aluminum alloy conductors.
Installed with Homac and competitive tools.
Made from high conductivity aluminum and prefilled with oxide inhibiting compound.
Marked with wire size, catalog number, installation die codes, compressionlocations and boxed with complete information printed on box.
Meets requirements of ANSI C119.4 specifications when properlyinstalled on aluminum to aluminum, or aluminum to copper conductors.
•
•••
•
•
* DIES: UT5 WITH “O” AND “D” DIES, AND UT-15 WITH “O”, “D”, “N”, OR “Z” DIES PER CHART.KEARNEY - “O” AND “D” MECHANICAL OR HYDRAULIC.BURNDY - “O” AND “D-3” MECHANICAL OR HYDRAULIC, AND “N”, “Z”, OR “R” HYDRAULIC.
** INSTALL WITH HYDRAULIC TOOLS ONLY.
HYD. DIE * LENGTH STYLE
5/8, TU 3/4 3
1 3/4 31-1/21-3/8 11-1/2 4
0 1-3/8 124
1-1/2 1
1-1/2 1
1-7/8 42 D 1-3/8
1-7/8 13 2-3/16
3 3-3/4 5
N 2-3/4 22
2-1/8 5
5 6 5
Z or R3 3 2
TA
P C
OV
ER
TA
P C
OV
ER
TA
P C
OV
ER
CO
20B
CN
600B
CD
40B
**
CATALOG NO. H L W
CO20B 2-1/4 4-1/2 1-5/8
CD40B 2-3/8 5-5/8 1-3/4CN600B 2-15/16 6-7/8 2-1/2
Fast, positive means for protecting tap connections.
Provides a close fitting top and bottom seal - secure double lockinglatches on both the hinge and locking side of the cover.
Highly reliable end enclosure - thin strips of the “grass skirt” moldaround the conductors.
Tapered drains in both cover halves prevent accumulation of water within the cover, regardless of which half of the cover is down.
Fabricated from black polypropylene, covers are highly resistant to weather,common contaminating elements, and the ultra-violet rays of the sun.
Homac Tap Covers •••••
1234567
Standard
OB44OB101DB202DB2020DB404DB4020DB4040
Long
OB1OB2DB3
DB2020DB5DB6DB7
Homac's 7 ConnectorProgram
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
94
Anti-Rotational Hot Line StirrupsStirrup connectors are used to protect conductorsfrom arc and mechanical damage where hot lineclamps are used.
These stirrups can be pre-loaded into a “hot stick”installing tool, hooked over the line and compressed.
Diamond knurling at tap connections and in the hotline clamping area improve both mechanical andelectrical performance.
Connectors are made from high conductivity aluminum.Factory installed bail is tin plated solid copper.
For easy identification, all connectors are marked withwire size, catalog number, installing die code, andcompression locations.
Connectors are prefilled with oxide inhibiting compound.
For aluminum, 5005, AAAC, and ACSR conductors.
•
•
•
•
•
••
CONDUCTOR SIZE
ACSR STR SOLCATALOGNUMBER A B DIE
44 - 2
4 - 1/03/0 - 4/0
266.8(18/1)- 397.5(18/1)397.5(26/7)
- 556.5(18/1)
44 - 2
2 - 1/03/0 - 4/0250(37)
- 400(37)
477 - 600
6 - 42--
-
-
OC42OC22OC102DC402
NC40010
NC60010
1 7/81 7/81 7/82 3/4
2 1/8
2222
1/0
OOOD
N
CATALOGNUMBER SIZE FIG. H L
HLB2
HLB10
*S4425
S4425 - 1/0
OL4425
2
1/0
2
1/0
2 3
1
2
2 3/8
2 3/4
3 1/8
4
4 1/4
4 3/8
4 1/4
BAILS
BAILS
*S4425 Bail has center split and isrecommended for H-Tap
applications.
'C' Type Stirrups
Crank TypeStirrups
CONDUCTOR SIZEACSR STR
CATALOGNUMBER A B C DIE
4
4 - 2
4 - 1/0
3/0 - 4/0
266.8(18/1) -
397.5(18/1)
397.5(26/7) -
556.5(18/1)
3/0 - 4/0
4/0 - 477(18/1)
6 SOL - 4
4 - 2
2 - 1/0
3/0 - 4/0
3/0 - 4/0
4/0 - 500
250(37) - 400(37)
477 - 600
OST42
OST22
OST102
DST402
*DB404ST
*NB50040ST
NST40010
NST60010
10
10
12
2
2/0
2
1/0
2 3/4
2 7/8
2 3/4
2 7/8
D
D
N
O
N
*Designates H-Tap Style
HLSCB-2HLCB-2
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
95
Anti-RotationalPaltap® Hot LineStirrups
Stirrup connectors are used to protect aluminumand ACSR main conductors from arc and mechanicaldamage where hot line clamps are used.
These stirrups can be pre-loaded into a “hot stick”installing tool, hooked over the line and compressed.
Paltap® connector is made from high conductivityaluminum. Factory installed bail is tin plated solid copper.
For easy identification, all connectors aremarked with wire size catalog number, installingdie code and compression locations.
Connectors are prefilled with HM54 inhibitor compound.
For aluminum, 5005, AAAC, and ACSR conductors.
•
•
•
•
••
MAIN CONDUCTOR
SOLID STRANDED ACSRCATALOGNUMBER A B
FIGURENUMBER
INSTALLINGDIES
4 & 6
2
-
-
6
4
2
1/0
6
4
2
1/0
QH6S
QH4S
SH2S
WH10
2 1/16
2 3/8
1
1 3/16
1
2
TQ, 12, 1/2
42
45, TS, 13, 9/16
TWTY, 15, 5/8-1, 54
Note: Bails may be ordered separately for field assembly of stirrups using Paltap® Connectors.Specify Catalog No. HLB2 for #2 tinned solid copper bail, or Catalog No. HLB10 for 1/0 tinned solid copper bail.
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
96
Green
Blue
Blue
Orange
Orange
Orange
Red
Red
Red
Red
Yellow
Yellow
Yellow
Yellow
Yellow
8
6
6
4
4
4
1 &2
1 &2
1 &2
1 &2
1/0
1/0
1/0
1/0
1/0
6
4
4
2
2
2
–
6-6/1
6-6/1
4-6/1,7/1
4-6/1,7/1
4-6/1,7/1
2-6/1,7/1
2-6/1,7/1
2-6/1,7/1
2-6/1,7/1
1/0-6/1
1/0-6/1
1/0-6/1
1/0-6/1
1/0-6/1
Green
Green
Blue
Green
Blue
Orange
Green
Blue
Orange
Red
Green
Blue
Orange
Red
Yellow
6
6
4
6
4
2
6
4
2
–
6
4
2
–
–
8
8
6
8
6
4
8
6
4
1 & 2
8
6
4
1 & 2
1/0
–
–
6-6/1
–
6-6/1
4-6/1, 7/1
–
6-6/1
4-6/1, 7/1
2-6/1, 7/1
–
6-6/1
4-6/1, 7/1
2-6/1, 7/1
1/0 - 6/1
Conductor A Conductor B
Color ColorSolid SolidStr. Str.ACSR ACSRAL or CU AL or CU Catalog
Number
UGG 88UBG 8UBB 66UOG 48UOB 46UOO 44URG 28URB 26URO 24URR 22UYG 08UYB 06UYO 04UYR 02UYY 00
Conductor A Conductor B
Color ColorSolid SolidStr. Str.ACSR ACSRAL or CU AL or CU
Catalog Number
Self Insulated
Un-Insulated
Brown
Green
Green
Blue
Blue
Blue
Orange
Orange
Orange
Orange
Red
Red
Red
Red
Red
Yellow
Yellow
Yellow
Yellow
Yellow
8
6
6
4
4
4
2
2
2
2
1
1
1
1
1
10
8
8
5 & 6
5 & 6
5 & 6
3 & 4
3 & 4
3 & 4
3 & 4
1 & 2
1 & 2
1 & 2
1 & 2
1 & 2
1/0
1/0
1/0
1/0
1/0
6-6/1
6-6/1
6-6/1
4-6/1,7/1
4-6/1, 7/1
4-6/1, 7/1
4-6/1, 7/1
2-6/1, 7/1
2-6/1, 7/1
2-6/1, 7/1
2-6/1, 7/1
2-6/1, 7/1
1/0-6/1
1/0-6/1
1/0-6/1
1/0-6/1
1/0-6/1
Brown
Green
Brown
Blue
Green
Brown
Orange
Blue
Green
Brown
Red
Orange
Blue
Green
Brown
Yellow
Red
Orange
Blue
Green
8
6
8
4
6
8
2
4
6
8
1
2
4
6
8
-
1
2
4
6
10
8
10
5 & 6
8
10
3 & 4
5 & 6
8
10
1 & 2
3 & 4
5 & 6
8
10
1/0
1 & 2
3 & 4
5 & 6
8
6-6/1
-
-
4-6/1, 7/1
6-6/1
-
-
2-6/1, 7/1
4-6/1, 7/1
6-6/1
-
-
1/0-6/1
2-6/1, 7/1
4-6/1, 7/1
6-6/1
-
U1N88
U1N81
U1N66
U1N68
U1N61
U1N44
U1N46
U1N48
U1N41
U1N22
U1N24
U1N26
U1N28
U1N21
U1N1010
U1N102
U1N104
U1N106
U1N108
U1B11
U1B88
U1B81
U1B66
U1B68
U1B61
U1B44
U1B46
U1B48
U1B41
U1B22
U1B24
U1B26
U1B28
U1B21
U1B1010
U1B102
U1B104
U1B106
U1B108
Installing Tools, Dies (Compressions per Side) Self Insulated and Uninsulated
EEI Die Code* UT3 Die Code UT5 Upper Die Code UT5 Lower Die Code Hydraulic
8A 5/8 (3) TU (2) H3 52
* When using EEI installing diesspace compression 1/8” apart.
For sizes not listed, pleaseconsult factory.
Use on U1B bare splices only.
Shure Splicer Connectors meet or exceedClass A-3 requirements of ANSI C119.4,when properly installed on aluminum toaluminum or aluminum to copperconductors.
High conductivity aluminum splices havesolid center barriers and large chamfers toease cable insertion. Coated with oxideinhibitor compound.
Tough stabil ized nylon sleeves resistinstalling tool pressure, provide reliable 600volt insulation.
Shure Splices are color coded and markedwith catalog numbers, strip lengths, installingdie references and compression locations.
Insulated ServiceEntrance Splicers5/8" Sizes
New Reduced Length
•
•
•
•
'U1N and 'U1B'Series ServiceEntrance SplicersStandard - LongLength
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
Overh
ead S
plicin
g
97
Insulated Service EntranceSplicers - 840 Size
Ideal for overhead services and mediumtension line connections.
High conductivity aluminum splices have solidcenter barriers and large chambers to easecable insertion. Coated with oxide inhibitorcompound.
Tough stabilized nylon sleeves resist installingtool pressure, provide reliable 600 volt insulation.
Shure Splices are color coded and marked withcatalog numbers, strip lengths, installing diereferences and compression locations.
•
•
•
•
Conductor ACATALOGNUMBER
Conductor B
ACSR ACSRCON-
CENTRICCON-
CENTRICCOM-
PRESSEDCOM-
PRESSED
1/02/01/03/02/01/04/03/02/01/0
COMPACT COMPACT
2/03/02/04/03/02/02504/03/02/0
1/0 1/0 1/0 1/0
2/0 2/0 2/0 2/0
3/0 3/0 3/0
4/0 4/0
4/0
2504/0
X1N1010X1N2020X1N2010X1N3030X1N3020X1N3010X1N4040X1N4030X1N4020X1N4010
Shure Splicers meet or exceed Class A Requirements of ANSI C119.4 INSTALLING TOOLS - TX-840-249-11A
1/02/01/03/02/01/04/03/02/01/0
1/02/01/03/02/01/04/03/02/01/0
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
98
Service EntranceSplicers - 840 Size
Conductor A Conductor B
CATALOGNUMBER Color Color
Solid SolidALAL CUCU Stranded StrandedACSR ACSR
OrangeOrange
RedOrange
RedYellowOrange
RedYellowGray
OrangeRed
YellowGrayBlack
OrangeRed
YellowGrayBlackPinkBlue
OrangeRed
YellowGrayBlackPink
Brown
OrangeRed
YellowGrayBlackPinkBlue
Orange
Red
Yellow
Gray
Black
Pink
Blue
Brown
2 2
1 1
1/02/0
3/0
3/0 3/0
1/0 1/0
2/0 2/0
4/0
4/0 4/0
350250to
266.8
397.5to
400
300to
350
336.4(18/1)
266.8
3 & 4 4
1 & 2 2
22121
1/0 & 2/021
1/0 & 2/03/021
1/0 & 2/03/04/021
1/0 & 2/03/04/0-
350
21
1/0 & 2/03/04/0-
397.5 to40021
1/0 & 2/03/04/0-
350
22121
21
21
21
21
21
3 & 43 & 41 & 23 & 41 & 21/0
3 & 41 & 21/02/0
3 & 41 & 21/02/03/0
3 & 41 & 21/02/03/04/0
250 to266.83 & 41 & 21/02/03/04/0
300 to350
3 & 41 & 21/02/03/04/0250
266.8
44242
1/042
1/02/042
1/02/03/042
1/02/03/04/0
266.8
42
1/02/03/04/0
336.4(18/1)
42
1/02/03/04/0
266.8
X1U44X1U24X1U22X1U104X1U102
X1U1010X1U204X1U202
X1U2010X1U2020X1U304X1U302
X1U3010X1U3020X1U3030X1U404X1U402
X1U4010X1U4020X1U4030X1U4040X1U266
X1U2664X1U2662
X1U26610X1U26620X1U26630X1U26640X1U336
X1U3364X1U3362
X1U33610X1U33620X1U33630X1U33640X1U33626
EEI*Die
Code
11A
Installing Tools, DiesUT5 Type Hydraulic
Die CodeUpper Lower Die Code
H5 H7 (6) 76 (2)
* When using EEI Installing Dies, space compressions 1/8” apart. (Compressions per Side)
For large residential and commerical service drops.
“840” Shure Splicer connectors meet or exceed Class A-2requirements of ANSI C119.4, when properly installed onaluminum to aluminum, or aluminum to copper conductors.
A solid center barrier provides for quick wire positioning, properdistribution of inhibitor around the wire, and current equalizationon stranded conductors.
Tested and approved for EEI installing dies.
••
•
•
A B
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
99
Semi-TensionNeutral Splicers
For splicing all ACSR or all aluminum neutral messengers of Triplex Service Cables.
Designed to develop 40% of the conductor’s rated strength to meet requirements of ANSI C119.4 specifications.
Made from high conductivity aluminum with an integral solid center stop.
Prefilled with oxide inhibiting compound and capped with color coded caps.
Marked with catalog number, installing die codes andcompression locations.
ACSR
642
1/0242
1/0
STR
642
1/01-242
1/0
STR
642
1/01-2642
CATALOGNUMBER
SNG 66SNG 44SNG 22SNG 00SNG 11SNG 46SNG 24SNG 02
INSTALLINGDIES
TU, 52, 5/8,BG, G,243, 8A
ACSR
642
1/02642
CONDUCTOR A CONDUCTOR B
•
•
•
•
•
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
100
Aluminum Loop SplicersFor ACSR, ACAR, AAAC, 5005 and AAC conductors.
Designed to develop 25% or more of the conductor’s rated strength to meet orexceed requirements of ANSI C119.4 specifications.
Made from high conductivity aluminum tubing.
For easy identification, all connectors are marked with wire size, catalog number,installing die code, and compression locations.
••
••
WIRE SIZEACSR, ACAR†5005†, AAAC AAC
CATALOGNUMBER L
EEI*DIE CODE
INSTALLING TOOLS AND DIES(Compressions per End)
DIES - UT5 TYPE DIES - HYDRAULIC
6 (6/1)-
4 (6/1, 7/1)-
2 (6/1, 7/1)-
1 (6/1)1/0 (6/1)2/0 (6/1)
-3/0 (6/1)4/0 (6/1)
266.8336.4 (18/1)
336.4397.5477
556.5605 to 666.6
715.5 to 874.5
-4-2-1-
1/02/03/03/0
4/0 - 250266 - 300336 - 350
336.4 - 350397.5 - 477500 - 556.6600 - 700
715.5 - 800874.5 - 1000
N1R3L1A5N1R5Q1A7*S1R7S1A8U1R8*Y1A9Z1A10Z1A51866*867*869
H1A33872*874*876*879883892
3 1/44 1/26 3/84 1/46 3/86 3/87 1/26 5/87 1/27 1/27 1/29 3/412 3/412 3/4
3 1/4 6A
8A-
10A11A
13A14A15A
---
TLTN (3)TLTN (3)TLTN (3)TQ (3)TS (3)TS (3)TU (3)
TWTY (4)TZ (6)TZ (4)TV (9)TX (9)TH (6)
45 (2)
52 (2)54 (2)60 (3)
66 (3)76 (3), 76H (6)87 (3), 87H (6)87 (3), 87H (6)96 (3), 96H (6)
106 (3), 106A (6)115(3), 115H (6)125 (3), 125H (6)140 (4), 140H (8)150(4), 150H (8)
* WHEN USING EEI DIES, SPACE COMPRESSIONS 1/8" APART.
† SELECT DIAMETER EQUIVALENT TO ACSR.
Copper Loop Splicers
WIRE SIZECATALOGNUMBER L
INSTALLING TOOLS AND DIES(Compressions per End)
DIES - UT5 TYPE DIES - HYDRAULIC8Sol.& Str.6 Sol. & Str.4 Sol. & Str.
2 Sol. & 2(7) Str.2(3) Str.1 Sol.
1(7-19) Str.1/0 Sol.
1/0(7-19) Str.2/0(7-19)Str.3/0(7-19) Str.4/0(7-19) Str.
J1CJJ1C3L1C5Q1C7S1C7S1C51S1C8S1C52U1C9390233902639029
2 1/4
4 1/4
4 1/2
TJ (2)TJ (2)
TLTN (2)TQ (2)
TU (4)TZ (4)
TS (4)
52 (2)58 (2)62 (2)71 (2)
For copper conductors.
Designed to develop 25% or more of the conductor’s rated strength and to exceed the conductivity of the conductor when installed.
Made from high conductivity seamless copper tubing.
For easy identification, all connectors are marked with wire size, catalog number, installing die code, and compression locations.
••
••
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
101
Tension SplicersSingle Sleeve ACSR & Aluminum Alloys
HOMAC single sleeve tension splicers are designed to simplify hot linedistribution construction and eliminate the need for separately splicing the core wires of ACSR.
Properly installed, they develop 95% or more of the conductors’ rated strengthexceeding requirements of ANSI C119.4 specifications.
The sleeves have an internal taper to provide a funnel-like entrance for easyinsertion of conductors and to provide stress relief on the conductor strands upon compression.
A solid barrier in the center of the sleeve assures all around distribution andpenetration of the compound to all strands.
Made from high conductivity seamless aluminum tubing and prefilled with oxide inhibiting compound.
Marked with catalog number, conductor size and die references.
WIRE SIZECATALOGNUMBER L
INSTALLINGDIES
#6AAC, 6ACSR (6/1)
#4AAC, 4ACSR(6/1)
#4AAAC
#4AAC, 4ACSR(6/1)
#4ACSR(7/1), 4AAAC
#4AAC, 4ACSR(6/1)
#4AAC, 4ACSR(6/1)
#4ACSR(7/1), 4AAAC
#2AAC, 2ACSR(6/1)
#2AAC, 2ACSR(6/1)
#2ACSR(7/1), 2AAAC
1/0AAC, 1/0ACSR(6/1)
1/0AAAC
1/0AAC, 1/0ACSR(6/1)
1/0AAAC
2/0AAC, 2/0ACSR(6/1)
2/0AAAC
3/0AAC, 3/0ACSR(6/1)
3/0AAAC
4/0AAC, 4/0ACSR(6/1)
4/0AAAC
266.8(18/1)ACSR
336.4(18/1)ACSR
397.5(18/1)ACSR
477(18/1)ACSR
BS66
GS467
DS26
16102
16104
16106
16477
BS46
BS467
QS467
DS267
WS10
RS10
MS20
16100
16101
6 5/8
10 3/8
12 1/4
21 1/4
19
28
30
9 7/16
10 3/8
10 3/8
11 1/4
12 3/8
13
17 7/8
17 7/8
17 7/8
TB, 239, 1/2
TD
BG, TWTY, 687
87H, 87
96, 655, 1 1/8-2, 13A
96
115H
TB, 239, 1/2
TB, 239, 1/2
TQ
BG, TWTY, 687
TWTY, 58
702
TM, 62, 11/16
76H, 658
87, 251
•
•
•
•
•
•
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
102
Tension Splicersfor All Aluminum Conductors
Homac tension splicers, properly installed, meet or exceedrequirements of ANSI C119.4 specifications developing 95% or moreof the conductors’ rated strength.
Internal taper permits easy insertion of conductors and provides stressrelief on conductor strands upon compression.
Made from high conductivity seamless aluminum tubing and have pre-coated contact surfaces.
Marked with catalog number, conductor size and die references.
•
•
•
•
WIRE SIZECATALOGNUMBER L
INSTALLING DIES
4 STR
2 STR
1/0
2/0 STR
2/0 STR
3/0 STR
3/0 STR
4/0 - 250 STR
266 - 300 STR
336.4 - 350 STR
397.5 - 400 STR
450 - 477 STR
556.5 STR
636 STR
750 - 795 STR
795 STR
874.5 - 1000 STR
L2A5
Q2A7
U2A9
W2A20
Z2A10
Z2A51
2169
2170
2174
2176
2178
2182
2183
2186
2187
2188
2190
4 1/4
4 1/2
6 1/4
6 1/2
6 1/2
6 1/2
8 1/4
8 1/4
10 3/8
10
10
13
10 3/8
13 3/8
13 3/8
13 3/8
13 3/8
TLTN, 162, 3/8
TQ, 163, 239, 1/2, 45, 6A
TU, 52, 243, 19/32, 8A
TWTY, 245, 635, 58, 9A
166
166
TV, 66, 694, 702, 781, 10A
TX, 66, 249, 840, 11A
87
96H, 655, 1 1/8 -1, 321, 13A
96H, 655, 1 1/8 -1, 13A
106, 14A
115H, 318, 1 5/16, 15A
125
140
140, 1 1/2
150
For wire sizes over 1000 MCM, please consult factory.
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
103
Tension Splicesfor Copper & Copperweld-Copper
Designed to develop 95% or more of the conductors’ rated strength.
For copper and copperweld-copper conductors.
Manufactured from high conductivity seamless copper tubing.
All connectors marked with wire size, catalog number, installing diesand compression locations.
••
•
•
WIRE SIZECATALOGNUMBER L
INSTALLINGDIES
8 SOL.& STR.
6 SOL.& STR.
4 SOL.
4 STR.
2 SOL.
2 (7) STR.
2 (3) STR.
1/0 SOL.
1/0 (7-19) STR.
2/0 (7-19) STR.
2/0 (7-19) STR.
3/0 (7-19) STR.
4/0 (7-19) STR.
J2C1
J2C3
L2C4
L2C5
Q2C6
Q2C7
S2C7
S2C52
U2C9
Z2C10
2723
2726
2729
1 15/16
2 1/4
3 1/4
3 1/4
4 3/8
4 3/8
4 1/4
4 1/4
5 1/4
5 1/4
6 1/2
6 1/2
8 3/8
TJ, 161
TJ, 161, J
TLTN, 162, 3/8
TLTN, 162, 3/8
TQ, 1/2, 163
TQ, 1/2, 163
TS, 9/16, 164
TS, 9/16, 164
TU
TZ, 166
58,245
62, 167
71, 840, 168
8A
6A
L2E1
L2E3
5 3/16
5 3/16
TLTN, 162
TLTN, 162
COPPER CONDUCTORS
COPPERWELD-COPPER CONDUCTORS
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
104
CATALOGNUMBER WIDTH LENGTH AREA GAUGE
GG324
GG288-E3
3"
7-1/2"
24"
38-1/2"
72 sq. in.
288 sq. in..060
Homac’s Ground Girdle System features:
Easy installation.
Lower cost than pole butt wrapping.
Captive high pressure connectors.
Adaptable for multiple grounding.
••••
Pole ButtGrounding Plate
Accommodates up to #2AWG Ground Wire.
Pole Butt Grounding Plates provide an economical means ofgrounding systems or equipment. A savings in material andtime over wrapping butt with copper wire.
These grounding plates have four moisture-retaining cups embossed on a solid copper plate. These cups,along withweight and natural vibration of the pose, tend to hold ground moisture around the plate maintaining a better ground.
CATALOGNUMBER
WIDTHOF PLATE
5575 7-1/2"
••
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
Gro
un
din
g S
ection
105
Service Connectors Split Bolt TypeStandard Type for 2 wires - For Copper and Copperweld wire. High Strength connectors made of highcopper content, corrosion resistant alloy for tapping, paralleling and dead-ending.
CatalogNumber
Wire Range (AWG)
Equal Main & Tap(Max. - Min.)
Min. Tap w/Max. Main
Nominal Dimensions
WireSlot
BodyWidth
NutWidth
E10
E8
E6
E4
E3
E2
E1/0
E2/0
E3/0
E250
E350
E500
E750
E1000
#10 Str.- #16 Str.
#8 Str.- #12 Sol.
#6 Str.- #10 Sol.
#4 Str.- #8 Sol.
#2 Sol.- #6 Sol.
#2 Str.- #6Sol.
1/0 Str.- #4 Sol.
2/0 Str.- #2 Sol.
3/0 Str.- #2 Sol.
250MCM - 1/0 Sol.
350MCM - 4/0 Str.
500MCM - 250MCM
750MCM - 350MCM
1000MCM - 500MCM
#16 Str.
#16 Str.
#16 Str.
#16 Str.
#16 Str.
#14 Str.
#14 Str.
#14 Str.
#12 Sol.
#8 Sol.
#8 Sol.
#8 Sol.
#8 Sol.
#8 Sol.
0.122
0.152
0.165
0.215
0.264
0.328
0.377
0.418
0.468
0.580
0.746
0.843
1.028
1.222
5/16
3/8
7/16
1/2
9/16
5/8
11/16
3/4
7/8
1
1-1/2
1-5/8
1-15/16
2-1/4
7/16
1/2
5/8
11/16
3/4
13/16
7/8
1
1-1/8
1-5/16
1-5/8
1-13/16
2-1/8
2-1/2
E8-L
E6S-L
E4S-L
E3-L
E2-L
#8 Str.- #12 Sol.
#6 Sol.- #10 Sol.
#4 Sol.- #8 Sol.
#2 Sol.- #6 Sol.
#2 Str.- #6 Sol.
#16 Str.
#16 Str.
#16 Str.
#16 Str.
#14 Str.
0.143
0.165
0.215
0.264
0.328
3/8
7/16
1/2
9/16
5/8
1/2
5/8
11/16
3/4
13/16
Standard Type for 3 wires.
General Purpose Type with spacer - For Aluminum, Copper, Steel wires and Combinations. Highstrength, high copper content, corrosion resistant alloy body, nut, spacer and pressure bar are electro-tinned for multi-material applications.
CatalogNumber
Wire Range (AWG)
Equal Main & Tap(Max. - Min.)
Min. Tap w/Max. Main
Nominal Dimensions
WireSlot
BodyWidth
NutWidth
Main or Tap(Max. Min.)
Copper and Aluminum ACSR
E10-GP
E8-GP
E6-GP
E4-GP
E3-GP
E2-GP
E1/0-GP
E2/0-GP
E3/0-GP
E250-GP
E350-GP
E500-GP
E750-GP
E1000-GP
#10 Str.- #16 Str.
#8 Str.- #16 Str.
#6 Sol.- #12 Str.
#4 Sol.- #10 Str.
#2 Sol.- #8 Str.
#2 Str.- #8 Sol.
1/0 Str.- #6 Sol.
2/0 Str.- #6 Sol.
3/0 Str.- #4 Str.
250MCM - #4 Str.
350MCM - 3/0 Str.
500MCM - 3/0 Str.
750MCM - 250MCM
1000MCM - 350MCM
#16 Str.
#16 Str.
#14 Str.
#10 Sol.
#10 Sol.
#8 Sol.
#10 Sol.
#10 Sol.
#6 Sol.
#4 Str,
#1 Sol.
1/0 Str.
2/0 Str.
3/0 Str.
-
-
-
6
4
2
1
1/0
2/0
4/0
350
477 18/1
666.6
900
-
-
-
-
6
6
6
6
6
4
2/0
2/0
4/0
300
0.122
0.152
0.165
0.215
0.264
0.328
0.377
0.418
0.468
0.580
0.746
0.843
1.028
1.222
5/16
3/8
7/16
1/2
9/16
5/8
11/16
3/4
7/8
1
1-1/2
1-5/8
1-15/16
2-1/4
7/16
1/2
5/8
11/16
3/4
13/16
7/8
1
1-1/8
1-5/16
1-5/8
1-13/16
2-1/8
2-1/2
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
106
Copper ‘C’ TapsHomac’s compression Copper ‘C’ Tap connectors offer conductorrange capability and are used for line tap-off and dead-ending.
Straight serrations designed into the run and tap grooves exertoptimum contact pressure on the solid and concentric conductors.
The connector can be held in the dies or jaws of an installation tool,then hooked directly over the line for time saving installationl.
•
•
•
Wire RangeA Groove B Groove
CatalogNumber
InstallationDies Length
6 Sol - 4 Str
6 Sol - 4 Str
2 Sol - 2 Str
2 Sol - 2 Str
3/0 Str - 4/0 Str
6 Sol - 6 Str
4 Sol - 4 Str
8 Sol - 4 Str
2 Sol - 2 Str
3/0 Str - 4/0 Str
CC46
CC44
*CC24
CC22
CC4040
TU, BG, 5/8
C
DF or D3
3/4
7/8
1-1/8
* When using #1 Str. in the A Groove, B Groove will accommodate 6,8 Str.,and 8 Sol.
Note: For splicing or grounding the plated concentric neutral, Homac recommendsTin Plated Taps. To specify Tin Plating add -TN to Cat. No. Example: CC22-TN.
Copperweld - Copper Conductor
8A - Use C -Tap accommodating 6 Str. Copper
6A - Use C -Tap accommodating 4 Str. Copper
4A - Use C -Tap accommodating 2 Str. Copper
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
107
Two Bolt Connectors Type 'TBC'
With Spacer - Tin Plated Type 'TBC-GP'
Compact, high strength, two bolt cast Copper alloy connector. The two bolt construction allowsmaximum pressure to be applied directly to the conductor strands. Recommended for heavy dutyconnections. No special tools are required - install with ordinary wrench or ratchet.
CATALOGNUMBER
TBC-350TBC-500TBC-800TBC-1000
RUN
250MCM-350MCM400MCM-500MCM400MCM-800MCM500MCM-1000MCM
TAP
10-350MCM10-500MCM3/0-800MCM3/0-1000MCM
Copper ConductorsD
1-3/8"1-1/2"1-5/8"
2"
H (apprx.)
2-1/2"3"
3-1/2"4"
W
2-1/8"2-9/32"2-1/2"
3"
LISTED
CATALOGNUMBER
*TBC-350 GP*TBC-500 GP*TBC-800 GP*TBC-1000 GP
RUN
250MCM-350MCM400MCM-500MCM400MCM-800MCM500MCM-1000MCM
TAP
6-350MCM4-500MCM
4/0-800MCM4/0-1000MCM
Aluminum and/or CopperD
1-3/8"1-1/2"1-5/8"
2"
H (apprx.)
2-3/4"3-5/32"3-3/4"4-3/8"
W
2-1/8"2-9/32"2-1/2"
3"
*UL LISTED FOR COPPER CONDUCTOR ONLY.
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
108
CATALOGNUMBER
FB11-2NR
FB12-2NR
FB13-2NR
FB14-2NR
FB21-2NR
FB22-2NR
FB23-2NR
FB24-2NR
FB31-2NR
FB32-2NR
FB33-2NR
FB34-2NR
FB41-2NR
FB42-2NR
FB43-2NR
FB44-2NR
NO. OF BRAIDSIN FERRULE
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
AMPERERATING (indoors)
190
340
470
600
330
530
700
850
360
600
820
1000
415
700
960
1200
A
3"
B
1-3/4"
C
5/8"
T
1/4"
1/4"
1/4"
5/16"
1/4"
1/4"
5/16"
3/8"
1/4"
7/16"
1/2"
5/8"
1/4"
1/2"
5/8"
7/8"
W
1-5/16"
1-5/16"
1-3/16"
1-3/16"
1-1/2"
1-5/8"
1-5/8"
1-5/8"
1-3/16"
1-3/16"
1-1/2"
1-5/8"
1-1/2"
1-1/2"
1-5/8"
1-5/8"
TOTAL CIRCULARMILS IN BRAID
(apprx)
77,000
154,500
231,500
309,000
154,500
309,000
463,000
617,500
231,500
463,000
694,500
926,000
309,000
617,500
926,000
1,235,000
Flexible BraidJumpersType FB for Flat to FlatFlexible braid jumpers are made of tinned flexiblecopper braid and high conductivity seamlesscopper ferrules. The jumpers are used as currentcarrying flexible joints that allow for expansion andvibration. Standard jumpers are assembled withtinned braid and tinned copper ferrules.
FB-1
FB-2
FB-3
FB-4
FLEXIBLE BRAIDSIDE VIEW
THE BRAIDS LISTED ABOVE ARE ALSO AVAILABLE IN 18" AND 24" LENGTHS.
TO ORDER, INSERT LENGTH DESIRED INTO CATALOG NUMBER BETWEEN THE 'N'AND 'R' - example: FB23-2N18R, FOR 18" LENGTH, FB23-2N24R, FOR 24" LENGTH.
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
109
Type VGN Ground Connector Cable to Flat
Cast Bronze Electric Power Connectors For Copper
Type VGM Ground Connector (2) Cables to Flat
Type VGR Ground Connector (2) Cables to Flat
Type VGE Ground Connector Cable to Flat
STYLE NUMBER
GB-8704
GB-8705
GB-8706
GB-8707
GB-8708
GB-8709
CABLE SIZE
#8-#4
#4-2/0
2/0-250
300-500
550-750
800-1000
J
3/8"
3/8"
1/2"
1/2"
1/2"
5/8"
A
1-1/4"
1-1/4"
1-1/2"
1-1/2"
1-1/2"
1-3/4"
B
1-1/4"
1-3/8"
1-1/2"
1-7/8"
2-1/8"
2-1/2"
STYLE NUMBER
GB-8696
GB-8697
GB-8698
GB-8699
GB-8700
GB-8701
CABLE SIZE
#8-#4
#4-2/0
2/0-250
300-500
550-750
800-1000
J
3/8"
3/8"
1/2"
1/2"
1/2"
5/8"
A
1-1/2"
1-1/2"
1-1/2"
2"
2"
2"
B
1-1/4"
1-1/2"
2"
2-1/2"
2-3/4"
3-1/8"
STYLE NUMBER
GB-8679
GB-8680
GB-8681
GB-8682
GB-8683
GB-8684
CABLE SIZE
#8-#4
#4-2/0
2/0-250
300-500
550-750
800-1000
J
3/8"
3/8"
1/2"
1/2"
1/2"
5/8"
A
1-1/4"
1-1/4"
1-1/4"
1-1/2"
1-1/2"
1-3/4"
B
1-1/4"
1-3/8"
1-1/2"
1-7/8"
2-1/8"
2-1/2"
STYLE NUMBER
GB-8739
GB-8740
GB-8741
GB-8742
GB-8743
GB-8744
CABLE SIZE
#8-#4
#4-2/0
2/0-250
300-500
550-750
800-1000
J
3/8"
3/8"
1/2"
1/2"
1/2"
5/8"
A
1-1/2"
1-1/2"
1-1/2"
2"
2"
2"
B
1-1/4"
1-1/2"
2"
2-1/2"
2-3/4"
3-1/8"
CABLE SIZES ARE AWG OR KCMIL. BOLTS SUPPLIED FOR 'T' EQUAL 1/4". SPECIFY OTHER 'T' IF REQUIRED.
CABLE SIZES ARE AWG OR KCMIL. BOLTS SUPPLIED FOR 'T' EQUAL 1/4". SPECIFY OTHER 'T' IF REQUIRED.
CABLE SIZES ARE AWG OR KCMIL. BOLTS SUPPLIED FOR 'T' EQUAL 1/4". SPECIFY OTHER 'T' IF REQUIRED.
CABLE SIZES ARE AWG OR KCMIL. BOLTS SUPPLIED FOR 'T' EQUAL 1/4". SPECIFY OTHER 'T' IF REQUIRED.
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
110
STYLE NUMBER
GB-8686
GB-8687
GB-8688
GB-8689
GB-8690
GB-8691
CABLE SIZE
#8-#4
#4-2/0
2/0-250
300-500
550-750
800-1000
J
3/8"
3/8"
3/8"
1/2"
1/2"
5/8"
A
2-1/4"
2-1/4"
2-1/4"
3"
3"
3-1/4"
B
1-1/4"
1-1/2"
2"
2-1/2"
2-3/4"
3-1/8"
C
1-1/8"
1-1/8"
1-1/8"
1-1/2"
1-1/2"
1-3/4"
Type VGD Ground Connector (2) Cables to Flat
Cast Bronze Electric Power Connectors For Copper
STYLE NUMBER
GB-8725
GB-8726
GB-8727
GB-8729
GB-8730
GB-8731
GB-8733
GB-8734
GB-8735
CABLE SIZE
#8-#4
#4-2/0
2/0-250
J
3/8"
1/2"
5/8"
3/8"
1/2"
5/8"
3/8"
1/2"
5/8"
A
1-1/8"
1-1/4"
1-3/8"
1-1/4"
1-3/8"
1-5/8"
1-1/2"
1-5/8"
1-7/8"
STYLE NUMBER
GB-8748
GB-8749
GB-8750
GB-8751
GB-8752
GB-8753
GB-8754
GB-8755
GB-8756
GB-8757
GB-8758
GB-8759
SPS
1/2
3/4
1
1-1/4
1-1/2
2
2-1/2
3
3-1/2
4
5
6
J
3/8"
3/8"
3/8"
3/8"
3/8"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
A
2-1/8"
2-3/8"
2-5/8"
3"
3-3/8"
3-3/4"
4-1/4"
4-7/8"
5-3/8"
5-7/8"
7"
8"
B
1-1/4"
1-1/4"
1-1/4"
1-1/4"
1-1/4"
1-1/2"
1-1/2"
1-1/2"
1-1/2"
1-1/2"
1-1/2"
1-1/2"
Type VGQ Ground Connector Cable to Flat
Type VGF Ground Connector Braid to Flat
CABLE SIZES ARE AWG OR KCMIL. BOLTS SUPPLIED FOR 'T' EQUAL 1/4". SPECIFY OTHER 'T' IF REQUIRED.
CABLE SIZES ARE AWG OR KCMIL. BOLTS SUPPLIED FOR 'T' EQUAL 1/4". SPECIFY OTHER 'T' IF REQUIRED.
CABLE SIZES ARE AWG OR KCMIL. BOLTS SUPPLIED FOR 'T' EQUAL 1/4". SPECIFY OTHER 'T' IF REQUIRED.
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
AL
/ CU
Mech
anical
Co
nn
ectors
111
Aluminum Screw LugsSingle Barrel Types
Made from high strength, high conductivity 6061-T6 aluminum alloy.
Compact design...light weight yet strong.
Require no special installation tools.
Electro-tin plated for low contact resistance and corrosion protection whenused with copper conductors.
UL Listed and CSA certified for use with copper and aluminum conductors.
Marked with catalog number and conductor range.
••••
••
File E50999
FIG. 1
FIG. 2
FIG. 3 FIG. 4 FIG. 5
File LR 35518
CATALOGNUMBER
WIRE RANGE(AWG)
FIG.NO. HEIGHT WIDTH LENGTH
BOLTSIZE
#6-#14
#2-#14
1/0-#14
2/0-#14
250MCM-#6
300MCM-#6
350MCM-#6
350MCM-#6
500MCM-#4
600MCM-#4or (2)250MCM-1/0
600MCM-#4
600MCM-#4
800-350MCM
800-350MCM
CU:800MCM-3/0AL:800-250MCM
1000-500MCM
1000-500MCM
1000-500MCM
A-35
A-90
A-125
A-150
A-250
A-300
A-350
A-350-2N
A-500
A-600CT
A-600
A-600-2N
A-800
A-800-2N
A-800S
A-1000
A-1000-2N
A-1000S
1
1
1
1
1
1
1
4
1
2
1
4
1
5
3
1
5
3
1/2
9/16
13/16
13/16
1-1/16
1-1/16
1-1/4
1-1/8
1-1/2
1-13/16
1-1/2
1-9/16
1-3/4
1-7/8
1-13/16
1-3/4
1-7/8
1-13/16
1/2
1/2
5/8
5/8
15/16
15/16
1-1/8
1-1/8
1-3/8
1-3/8
1-3/8
1-1/2
1-1/2
1-3/4
1-5/16
1-1/2
1-3/4
1-7/16
1-1/16
1-5/32
1-15/32
1-15/32
2
2
2-1/4
4-1/2
2-3/4
2-13/16
2-3/4
4-11/16
3-1/2
6-3/16
3-1/4
3-1/2
6-3/16
3-1/4
1/4
1/4
1/4
1/4
5/16
5/16
5/16
1/2
3/8
3/8
3/8
1/2
1/2
1/2
5/8
1/2
1/2
5/8
‘N’ suffix on Cat. # indicates NEMA Bolt Hole Spacing of 1-3/4”.
Single Barrel Aluminum Screw Lugs Type ‘A’
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
112
TWO BARREL - ONE HOLE AND TWO HOLE PAD
Wire Range(AWG)
CatalogNumber
Fig.No. Height Width Length
BoltSize
(2) 1/0-#14(2) 2/0-#14
(2) 250MCM-#6(2) 350MCM-#6(2) 350MCM-#6(2) 600MCM-#4(2) 600MCM-#4
(2) 800-350MCM(2) 800-350MCM
(2) 1000-500MCM
AD-125† AD-150AD-250AD-350
AD-350-2NAD-600
AD-600-2NAD-800
*† AD-800-2N*† AD1000
1122323242
13/1613/161-3/161-1/41-1/8
1-9/161-9/161-11/161-7/8
1-11/16
1-3/161-3/161-5/8
1-15/162-1/42-3/8
2-7/162-13/163-3/16
2-13/16
1-1/21-1/2
2-9/162-7/84-1/23-1/8
4-11/163-1/2
6-3/163-1/2
1/41/43/81/21/21/21/25/81/25/8
FIG. 1
FIG. 2
** FIG. 4
Aluminum Screw LugsTwo Barrel and Switchgear Types
Made from high strength, high conductivity 6061-T6 aluminum alloy.Compact design...lightweight yet strong.
Require no special installation tools.
Electro-tin plated for low contact resistance and corrosion protectionwhen used with copper conductors.
UL listed and CSA certified for use with copper and aluminum conductors (**except Fig.4).
Marked with catalog number and conductor range.
••••
••
File E50999
Height Width LengthBoltSize
‘N’ suffix on Cat. # indicates NEMA Bolt Hole Spacing of 1-3/4”.
ONE BARREL - TWO HOLE PAD, SWITCHGEAR TYPE
Wire Range(AWG)
CatalogNumber
Fig.No.
#2-#82/0-#8
250MCM-3/0350MCM-4/0500-400MCM800-350MCM
† ASG-2*† ASG-2/0† ASG-250† ASG-350† ASG-500† ASG-800
112334
5/815/1615/161-9/161-9/161-7/8
111
1-1/81-3/81-5/8
2-3/433
4-11/164-11/166-3/16
3/83/83/81/21/21/2
Bolt Hole
Spacing
111
1-1/21-1/21-1/2
Height Width LengthBoltSize
DUAL RATED LAY-IN LUGS
Wire Range(AWG)
CatalogNumber
#4 - #141/0 - #8
250MCM - #6
CLA-70-219CLA-125-270CLA-250-330
3/41-7/16
1-45/64
25/641-39/642-13/64
1-5/641-1/2
2-13/64
#101/4
5/16
FIG. 1
FIG. 3FIG. 4
File LR 35518
† except asindicated* except as
indicated
FIG. 3
FIG. 2
12 Southland Road, Ormond Beach, FL 32174 • Phone: 386-677-9110 • Fax: 386.673.5497 • E-mail: [email protected] • www.homac.com
113
Aluminum Screw LugsMultiple Barrel Types
Made from high strength, high conductivity 6061-T6 aluminum alloy.
Compact design...lightweight yet strong.
Require no special installation tools.
Electro-tin plated for low contact resistance and corrosion protection whenused with copper conductors.
Marked with catalog number and conductor range.
••••
•
Wire Range(AWG)
Catalog Number
Fig.No. Height Width Length
BoltSize
BoltHole
Spacing
#2-#141/0-#123/0-#63/0-#6
250MCM-#6250MCM-#6350MCM-#6350MCM-#6600MCM-#2600MCM-#2800-350MCM800-350MCM1000-500MCM
AT3A2-2AT3A2-0
AT3A2-3/0AT3A2-3/0NAT3A2-250
AT3A2-250NAT3A2-350
AT3A2-350NAT3A2-600
AT3A2-600NAT3A2-800
AT3A2-800NAT3A2-1000N
5/8
1
1-1/8
1-1/4
1-7/8
1-15/16
2-13/16
3
3-3/4
4-1/4
4-3/4
2-15/16
4-3/8
4-1/2
3-15/164-5/8
6-3/16
3/8
1/2
3/8
1/2
1
1-3/4
1-3/81-3/41-5/8
1-3/4
1
2
Wire Range(AWG)
CatalogNumber
Fig.No. Height Width Length
BoltSize
BoltHole
Spacing
#2-#14
1/0-#12
3/0-#6
3/0-#6
250MCM-#6
250MCM-#6
350MCM-#6
350MCM-#6
600MCM-#2
600MCM-#2
800-350MCM
800-350MCM
1000-500MCM
AT3A4-2
AT3A4-0
AT3A4-3/0
AT3A4-3/0N
AT3A4-250
AT3A4-250N
AT3A4-350
At3A4-350N
AT3A4-600
AT3A4-600N
AT3A4-800
AT3A4-800N
AT3A4-1000N
1-3/8
1-3/4
1-5/8
250MCM-#6
350MCM-#6
600MCM-#2
800-350MCM
AT4A4-250N
AT4A4-350N
AT4A4-600N
AT4A4-800N
5
6
1
1-1/8
1-9/16
1-7/8
3-11/16
3-15/16
5
5-5/8
4-3/8
4-1/2
4-5/8
6-3/16
3
4
5/8
1
1-1/8
1-1/4
1-7/8
1-15/16
2-13/16
3
3-3/4
4-1/4
4-3/4
2-15/16
4-3/8
4-1/2
3-15/16
4-5/8
6-3/16
3/8
1/2
3/8
1/2
1
1-3/4
1-3/4
1/2 1-3/4
THREE BARREL - TWO HOLE PAD
THREE & FOUR BARREL - FOUR HOLE PAD
‘N’ SUFFIX ON CATALOG NUMBER INDICATES NEMA BOLT HOLE SPACING, 1-3/4"
Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
114
Panelboard Lugs and Neutral Bar AssembliesMade from high strength, high conductivity 6061-T6 aluminum alloy.
Compact design...lightweight yet strong.
Require no special installation tools.
Electro-tin plated for low contact resistance and corrosion protection when used with copper conductors.
UL listed and CSA certified for use with copper and aluminum conductors (* Except Fig.1).
Marked with catalog number and conductor range.
Wire Range(AWG)
CatalogNumber
Fig.No. Height Width Length
BoltSize
BoltHole
Spacing
(2)600MCM-#2
(2)600MCM-#2
(2)750MCM-3/0
(2)800-350MCM
(3)600MCM-#2
(3)750MCM-3/0
(4)600MCM-#2
(4)750MCM-3/0
AX2-600
AQ2-600
AQ2-750
AQ2-800
AQ3-600
AQ3-750
AQ4-600
AQ4-750
1
2
2-13/16 1-3/8
1-1/2
2-1/2
2-5/8
2-1/2
2-5/8
3-13/16
Panelboard Aluminum Screw Lugs Type “AX” and “AQ”
3
4
3 4-15/163/8 1-3/8
••••••
ANA-350-12
ANA-350-24
ANA-350-30
ANA-350-36
ANA-350-42
#8-#14350MCM-#6
12
24
30
36
42
1-9/16 4-1/8
4-3/4
5-3/8
2-1/2 3/16
Wire Range(AWG)
CircuitTaps
CatalogNumber
CircuitTaps
Heightwith Max.
Wire Width LengthBoltSize
Aluminum Neutral Bar Assembly Type “ANA”
4-3/4
* Fig. 1 Fig. 2
Fig. 3 Fig. 4
ANA-350-42 shownFile E50999
File E50999
File LR 35518
Wire Range(AWG)
CatalogNumber Width Length X Dimension
BoltSize
#4-#14
1/0-#14
2/0-#14
300MCM-#6
350MCM-#6
(1) 600-250MCM
(2) 250MCM-#2
600MCM-#4
(2)600MCM-#4
A70-L
A125-L
A150-L
A300-L
A350-L
A600L
AD600-L
1/2
5/8
5/8
15/16
1
1-3/8
2-3/8
1-5/32
1-15/32
1-15/32
1-29/32
2-3/4
3-1/8
33/64
1/2
15/32
5/8
1/2
7/8
1/2
1/4
1/4
1/4
1/4
5/16
3/8
1/2
A600CT-L 1-3/8 2-13/16 1-9/64 3/8
Locking Feature Lugs, Type ‘A-L’Locking feature prevents turning of connector.
CONSULT FACTORY FOR SPECIAL REQUIREMENTS
File E50999
X Dimension
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
115
Copper Screw LugsOffset Tang Types
Made from seamless, pure electrolytic copper.
100% conductivity for highest efficiency.
Completely reusable.
Require no special installation tools.
Available in plain copper finish or, upon special request, with tin or flash - silver plating.
UL listed and CSA certified for use with copper conductor.
Marked with catalog number and conductor range.
WireRange(AWG)
CurrentRatingAmps.
CatalogNumber
Heightwith Max.
WireTangWidth Length
BoltSize
#10-#14
#6-#14 & Comb.
#4-#14
#2-#8 & Comb.
1/0-#2
3/0-#4
4/0-#2
350MCM-1/0
500MCM-1/0
1000-600MCM
25
50
70
90
125
175
225
300
400
650
CB-25
CB-35
CBA-70
CB-70
CB-125
CB-175
CB-225
CB-300
CB-400
CB-650
11/16
3/4
13/16
1
1-3/8
1-9/16
2
2-5/8
2-3/4
3-11/16
5/16
3/8
1/2
1/2
5/8
3/4
1
1
1-1/2
2
1
1-3/16
1-5/16
1-17/32
1-31/32
2-3/16
2-5/8
3-3/16
4-1/4
4-5/8
1/8
3/16
1/4
1/4
1/4
3/8
5/16
3/8
3/8
1/2
Single Hole-Offset Tang Copper Screw Lugs
BoltSizeLength
TangWidth
Heightwith Max.
WireCatalogNumber
CurrentRating Amps.
WireRange(AWG)
(2)4/0-#6
(2)350MCM-1/0
(2)500MCM-1/0
450
600
800
DC-450
DC-600
DC-800
2
2-1/4
2-9/16
1-1/2
1-3/4
2
3-3/8
3-5/8
4-7/16
3/8
3/8
1/2
Double Barrel, Single Hole-Offset Tang Copper Screw Lugs
•••••••
File LR 35518
File E50999
File E50999
File E50999
File LR 35518
#6-#14 & Comb.
#2-#8 & Comb.
1/0-#2
4/0-#2
350MCM-1/0
500MCM-1/0
1000-600MCM
50
90
125
225
300
400
650
CO-35
CO-70
CO-125
CO-225
CO-300
CO-400
CO-650
3/4
1
1-3/8
1-13/16
2-5/8
2-3/4
3-11/16
3/8
1/2
5/8
1
1
1-1/2
2
2-3/16
2-5/16
2-31/32
3-5/8
5-11/16
6
6-3/8
3/16
1/4
1/4
5/16
3/8
3/8
1/2
1
1
1
1
1-7/8
1-3/4
1-3/4
WireRange(AWG)
CurrentRatingAmps.
CatalogNumber
Heightwith Max.
WireTangWidth Length
BoltSize
BoltHole
Spacing
Two Hole-Offset Tang Copper Screw Lugs
Type “CO”
Type “DC”
Type “CB”
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
116
WireRange(AWG)
CurrentRatingAmps.
CatalogNumber
Heightwith Max.
WireTangWidth Length
BoltSize
#10-#14#6-#14 & Comb.
#4-#14#2-#8 & Comb.
1/0-#23/0-#44/0-#2
350MCM-1/0500MCM-1/0
1000-600MCM
25507090125175225300400650
CS-25CS-35
CSA-70CS-70CS-125CS-175CS-225CS-300CS-400CS-650
5/811/167/81
1-1/41-9/161-11/162-3/82-9/163-11/16
5/163/81/21/25/83/411
1-1/22
61/641-9/641-1/4
1-15/321-15/162-3/162-3/83-3/163-7/85-1/8
1/83/161/41/41/43/85/163/83/81/2
Single Hole-Straight Tang Copper Screw Lugs
Copper Screw LugsStraight Tang Types
Made from seamless, pure electrolytic copper.
100% conductivity for highest efficiency.
Completely reusable.
Require no special installation tools.
Available in plain copper finish or, upon special request, with tin or flash - silver plating.
UL listed and CSA certified for use with copper conductor.
Marked with catalog number and conductor range.
•••••••
File E50999
File LR 35518
BoltHole
SpacingBoltSizeLength
TangWidth
Heightwith Max.
WireCatalogNumber
CurrentRatingAmps.
WireRange(AWG)
#6-#14 & Comb.#2-#8 & Comb.
1/0-#24/0-#2
350MCM-1/0500MCM-1/0
1000-600MCM
5090125225300400650
CD-35CD-70CD-125CD-225CD-300CD-400CD-650
11/161
1-1/41-11/162-5/82-9/163-11/16
3/81/25/811
1-1/22
2-1/82-1/4
2-15/163-3/8
4-15/165-5/86-7/8
3/161/41/45/163/83/81/2
11111
1-3/41-3/4
Two Hole-Straight Tang Copper Screw Lugs
File LR 35518
File E50999
File LR 35518
File E50999
WireRange(AWG)
CurrentRatingAmps.
CatalogNumber
Heightwith Max.
WireTangWidth Length
BoltSize
#6-#14#4-#14 & Comb.1/0-#4 & Comb.
4/0-#2500MCM-4/0
5070125225400
CX-35CX-70CX-125CX-225CX-400
3/45/81
1-5/82-9/16
3/81/25/81
1-1/2
11-1/41-9/162-3/163-3/16
3/161/41/45/163/8
Single Hole Copper Screw Lugs
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
117
Copper Screw LugsStraight Tang Types andNeutral Bar Assemblies
Made from seamless, pure electrolytic copper.
Completely reusable.
Require no special installation tools.
Available in plain copper finish or, upon special request, with tin or flash - silver plating.
UL listed* for use with copper conductor. *(except for Neutral bar assemblies)
Marked with catalog number and conductor range.
••••••
WireRange(AWG)
CurrentRatingAmps.
CatalogNumber
Fig.No.
Heightwith Max.
WireTangWidth Length
BoltSize
1/0-#14
250MCM-#6
350MCM-#1
350MCM-#1
500MCM-4/0
600MCM-1/0
125
250
400
450
CP-125
CP-250
CP-300S
CP-300
CP-400
CP-450
1
2
11/16
15/16
1-9/16
1-1/2
3/4
1
1-3/4
2-1/4
2-7/32
2-11/16
3-5/16
3-5/8
5/16
1/2
3/8
Single Hole Copper Screw Lugs
300 1-1/4 1-1/8
1-1/2
1/4
File E50999
WireRange(AWG)
CurrentRatingAmps.
CatalogNumber
Fig.No.
Heightwith Max.
WireTangWidth Length
BoltSize
BoltHole
Spacing
1/0-#14
250MCM-#6
350MCM-#1
600MCM-1/0
125
250
300
450
CP-125-2
CP-250-2
CP-300-2
CP-450-2
1
2
11/16
1-1/2
3/4
1
1-1/8
1-1/4
2-1/2
3
3-1/2
3-7/8
1/4
5/16
3/8
1/2
7/8
1
Two Hole Copper Screw Lugs
1-1/4
1-1/16
File E50999
WireRange(AWG)
CatalogNumber Length
CircuitTaps
CircuitTaps Height Width
MountingHoles
250MCM-#6 #6-#14
NBL-240
NBL-300
NBL-360
NBL-420
24
30
36
42
1-5/16
1-7/16
5-1/8
4-13/32
5-1/8
5-1/2
2-5/16
3
Two(2) #10-32
Tapped Holes
Copper Neutral Bar Assemblies
Fig. 2
Fig. 2
Fig. 1
Fig. 1
NBL-360 with 36 circuit shown
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
118
CopperMechanical LugsML Series
Made from pure electrolytic copper...100% conductive.
Bright copper finish standard.*
One piece - flat bottomed, for full contact, highest efficiency.
Completely re-useable.
No special installation tools required.
Metal stamped with catalog number and conductor range.
UL listed for use with copper conductor (Test 486A).
WireRange
CatalogNumber
BoltSize Width Height
PadThickness Length Installing Tool
#14-#8
#14-#4
#8-1/0
#6-250 MCM
ML- 8
ML- 4
ML- 1/0
ML-250
3/16
1/4
5/16
3/8
3/8
1/2
3/4
15/16
3/8
17/32
3/4
1-1/16
5/64
3/32
3/32
1/8
13/16
1-1/8
1-1/2
1-15/16
Slot Screw Driver
1/4” Hex Wrench
* FOR TIN PLATING ADD SUFFIX TN TO CATALOG NUMBER, EG. ML-8 TN.
•••••••
File E50999
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
Too
ls
119
NEW Improved UT3-M Installing Tool
UT3 Installing Toolfor 1/2" and 5/8"compression connectors
Built in 5/8" die installs compression connectors from #8 to 4/0.
Lightweight, only 2.2 pounds.
Fast, one stroke of the tool develops full compression.
Positive crimps, SHURE-SQUEEZER® design assures proper compressionbefore jaws will release.
No dies to lose, 5/8" die is precision cast and machined as part of the tool.
Backed by Homac's guaranteed maintenance program.
•••
••
Connectorsinstalled withboth the UT3-Mand UT3 tool.
Same great features at the UT3-M tool, except has a removable,reversible die that installs 1/2" and 5/8" compression connectors.
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
120
NEWDie Retaining Spring
Upper Die
Lower Die
Lower DieLocking Pin
NEWEPDM Rubber
Insulated
NEWEqual Length
Hardwood Handles
UT5 Compression Tool
Installing Dies
RUGGED CONSTRUCTION AND QUALITY MATERIALS ENSURE CONSISTENTRELIABLE CONNECTIONS, EVERY TIME!
Three pivot points allow complete compression withless handle force than single pivot point scissor type tools.
Provides 5 tons compression force, yet weighs in at only 7.4 pounds.
'C' shape installing head design makes it easier to position and operate the tool.
•
••
Installing die blocks for the UT5 tool have been designed to include variouscombinations of upper dies so that a minimum number of dies need to be ordered.
Upper dies are furnished with four or two installing dies per block - in many cases, two upper die blocks with one lower die meet all installing requirements.
•
•
the WorkhorseOF COMPRESSION TOOLS!
UPPER DIECAT. NO.
H1
H2
H5
H6
LOWER DIECAT. NO.
H3
H7
DIEGROOVES
TQ(1/2), TWTYTD, TU(5/8)
TS, TB,TJ, TLTN
TX(840)TU(5/8)
TM, TR
UPPER DIE BLOCKS
'O' DIE SET 'D' DIE SET
ORDERED AS SETS
UPPER DIE BLOCKS
LOWER DIE
LOWER DIE
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
121
UT15
UT15N
UT15 Product Profile
UT15 Product Profile
The UT15 hydraulic head with associated dies installs full tensionconnectors for conductors up to 1000 MCM all aluminum, 350 MCMhard drawn copper, and 954 MCM ACSR (max. 7 steel strands). Italso accommodates all non-tension type fittings up to 1000 MCM.The large opening between the dies permits this tool to be placeddirectly over the connectors or be installed. This eliminates the needfor additional insulation removal.
Installing dies are available in two types. The 15C dies series, forlarger size conductors, fits directly into the tool. The 15CA seriesdies are used in conjunction with the 15CAP adapter. (This sameadapter accommodates other 12 ton "shell type" dies in the UT15).Both installing dies series provide round or hex compression-maximum area of reduction with uniform all-round pressure on allconductor strands. DO NOT OPERATE TOOL WITHOUT DIES INPOSITION.
Weighing approximately 15-1/2 pounds, the UT15 is ideal for hotline installations. A hot stick clamp adapter attached to the headcylinder allows the head to be used in any position and with anyuniversal hot stick.
Air operated, battery operated, or AC-DC electric pumps areavailable as a power source. High pressure non-metallic hydraulichoses in various lengths are also available.
Output:
OperatingPressure:
Tool Weight:
15 ton nominal
10,000 p.s.i. nominal (safety bypass on pumpset at 9,800 p.s.i.)
15-1/2 pounds (without dies, includes oil inthe cylinder)
Carrying case is providedwith each UT15 tool.Additional cases may beordered as CatalogNumber 15599
UT15 comes complete with steel carrying case. Installingdies, pumps and accessories must be ordered separately.
UT15N Product ProfileThe UT15N is the UT15 head with an impact-resistant PVCcovering designed as added protection against accidental contactwith energized conductors. (Not to be considered as insulation forhot line work). Lower half of covering is removable for servicing oftool. NOTE: DO NOT OPERATE TOOL WITHOUTDIES IN POSITION.
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
122
UT15 Installing Dies Cat. No. 15CAP: Adapter inserts into UT15 tool to accommodate15CA series dies or any 12 ton shell type dies. Required for all15CA dies.
15CA series Die Blocks: Use with catalog number 15CAPadapter in UT15 tool. Use these same dies in any 12 ton headthat utilizes shell type dies.
15C-R series Die Blocks: Round dies for smooth, high voltagecompression. Also suitable for low voltage use.
15C series Die Blocks: Designed for use in the UT15, noadapter required. These dies install anything above 556.5 MCMplus 'N' and 'Z' type connectors
15CA15CAP
15C
DIE CODEREFERENCE NO.
21
26
30
32H
37
42H
45
49
52
54H
58
58H
59H
60
62*
62S*
66
67H
71H
74H
76
80H
83H
87†
87H†
94H
96
96H
99H
106A†
115H
125H
140H
150H
O
D
N
Z
EEI DIE CODE
1S
2S
3S
4S
5S
6A
7A
8A
9A
9A
10A
11A
12A
12A
13A
13A
14A
15A
-
ORDER DIE**CAT. NO.
15CA21
15CA26
15CA30
15CA32H
15CA37
15CA42H
15CA45
15CA49
15CA52
15CA54H
15CA58
15CA58H
15CA60
15CA62
15CA66
15CA71H
15CA76
15CA87H
15CA96H
15CA99H
15CA106A
15CA115H
15CAO
15CAD
ORDER DIECAT. NO.
-
-
15C59H
15C62S
15C67H
15C74H
15C80H
15C83H
15C87
15C94H
15C98
15C125H
15C140H
15C150H
15CN
15CZ
*Die Code 62 is designed for use only on aluminum or copperaccessories. Die Code 62S is used on steel overhead accessories(space compressions as indicated on fitting or 1/8" apart).
†Die Codes 87, 150H and 106A are used for ACSR (outer sleeve)and AA accessories; do not use these dies on copper or steeloverhead accessories. Die Code 87H can be used on copperoverhead accessories.
NOTE: 1) Suffix 'H' on any die code indicates a half width die - twospaced 'H' width compressions equal one full compression.
NOTE: 2) Proper compression is obtained with the UT15 when backedge of upper and lower dies touch (front edge of dies can be slightly opened).
** These dies require adapter Cat. No. 15CAP.
CATALOGNUMBER
1357013571135721357313574
LENGTH
6'10'15'20'25'
Cat. No. SPC 21851 Male Coupler /Cat. No. SPC 21852 Female Coupler
Both male and female couplers are furnished with dust caps. Available as replacementitems, or to convert present hydraulic hoses for use on Somerset hydraulic pumps andinstalling tools.
Cat. No. 15596 Electric Hydraulic PumpSpecifications
Motor:
Pumping Capacity:
Output Pressure:Reservoir Volume:Weight incl. oil:Overall Dim's.:
1/2 H.P. - 115 volts AC-DC single phase input -1500 watts160 cu. in. per min. @ 100 p.s.i.20 cu. in. per min. @ 1000 p.s.i.9800 p.s.i. with safety by-pass1-1/2 qts. (type 'A' automatic transmission oil)26 lbs.Base 6-1/2" x 6", Height 14-1/2"
Above pump comes complete with an 8'remote control cord and a sturdy steel carryingcase. Consult factory for availability or 12 or24 volt DC pumps.
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
12 SOUTHLAND RD. ORMOND BEACH, FL 32174TELEPHONE 904-677-9110 FAX 904-673-5497
123
Battery Powered Dieless Crimping ToolsModel REC - 630 ROBO CRIMPBattery Powered Dieless Crimping Tool
Model REC - 750 ROBO CRIMPBattery Powered Flip-top Dieless Crimping Tool
Connector range: #10 AWG - 500 MCM
Connector range:#10 AWG - 500 MCM
The REC-630 is a battery operated, dieless compression tool used tocompress multi-range taking lugs.
Six tons of compression force are achieved when the tool advances andby-passes at the predetermined pressure.
Advance and retract buttons on the tool handle allow for one handoperation, freeing the other hand to maneuver the cable.
The REC-750 is a flip-top, battery operated, dieless compression toolused to crimp cables up to 750 MCM.
The flip-top latch opens to allow for easy cable positioning and removal.The dieless system is used for non-tension splices and terminations.
There is one stationary and three movable indenting nibs which close at90° angles to each other so that the connector is squeezed equally atfour strategic points with 6 tons of force. The top can be unlatched toaccommodate larger size lugs and cables up to 750 MCM.
Typical applications include in-line splicing connectors and lugs andterminations.
Specifications:
Output..........................
Weight........
Size.....................
Jaw Opening.....................
Center Opening...............
Standard ROBO Kit includes:
1 Battery Powered Tool
1 Carrying Strap
1 Carrying Case
2 BP-70R Batteries
1 CH-3TR 15 minute AC Charger
6.2 ton
11.5 lbs. w/battery
14"x13"x2.5"
.91"
1.25"
Specifications:
Output..........................
Weight........
Size.....................
Jaw Opening.....................
Center Opening...............
6.2 ton
11.5 lbs. w/battery
14"x13"x2.5"
.91"
1.25"
Standard ROBO Kit includes:
1 Battery Powered Tool
1 Carrying Strap
1 Carrying Case
2 BP-70R Batteries
1 CH-3TR 15 minute AC Charger
Note: Both the REC-630 and REC-750 were designed to install multi-range taking style connectors. Other connectorsmanufactured to ANSI specification C119.4 can be used. The cable must be the maximum size specified for the connector.Consult your connector manufacturer for dieless applications.
12 SOUTHLAND RD. ORMOND BEACH, FL 32174TELEPHONE 904-677-9110 FAX 904-673-5497
124
Hand Operated Dieless Crimping Tools
Model EP-630 ROBO CRIMPDieless Crimping Tool
Model EP-750 ROBO CRIMPFlip-Top Dieless Crimping Tool
Two-stage pumping piston forrapid advance.
Replaceable, drop-out bypasscartridge for easy shop repairs.
360° swivel crimping headpermits installations in confinedareas.
Magnetic oil reservoir plug totrap metal contaminants.
Twist handle release.
The EP-630 is commonly used byelectric utilities and contractors whoprefer the dieless compression tocircumferencial compression.
The operator positions a connector inthe jaws and pumps until the toolbypasses at 6.2 tons of output. Threemoveable nibs crimp the connectoragainst a fourth stationary nib.Carrying case included.
The EP-750 operates the same as theEP-630, except it has a largerconnector/cable capacity. Largercables can be inserted and easilyremoved by opening the flip-top head.
•••
••
Two-stage pumping piston forrapid advance.
Replaceable, drop-out bypasscartridge for easy shop repairs.
360° swivel crimping headpermits installations in confinedareas.
Magnetic oil reservoir plug totrap metal contaminants.
Twist handle release.
•••
••
Connector range: #10 AWG - 500 MCM
Connector range: #10 AWG - 750 MCM
Specifications:
Output..........................
Weight........................
Size....................................
Jaw Opening.....................
Center Opening...............
6.2 ton
11.5 lbs.
22"
.91"
1.25"
Specifications:
Output..........................
Weight........................
Length...............................
Jaw Opening.....................
6.2 ton
11.5 lbs.
23"
1.5"
Note: The EP-630 was designed toinstall multi-range taking styleconnectors. Consult your connectormanufacturer for diesless applications.
Note: The EP-630 was designed toinstall multi-range taking styleconnectors. Consult your connectormanufacturer for diesless applications.
125
Utility Cable SlicersThe drop forged cutter blades and fiberglass handles are designed for easy field replacement.
Fiberglass handles make a safe, rugged lightweight tool that will givemany years of dependable service.
Slicing action of cutter blade provides flush, burr-free conductor ends.
Handle stops prevent “knuckle busting” during operation.
•
•
••
MAXIMUMCONDUCTOR SIZE
600 MCM Aluminum350 MCM Copper
1000 MCM Aluminum500 MCM Copper
CATALOGNUMBER
UT4C
UT6C
OVERALLLENGTH
21"
31-1/2"
WEIGHT
2-3/4 Lbs.
6-3/4 Lbs.
MAX. O.D.INCLUDINGINSULATION
1-5/16"
2"
TOOL CAT.NUMBER
UT4C
UT6C
BLADE ASSEMBLYCATALOG NUMBER
UT4-B
UT6-B
HANDLESCATALOG NUMBER
UT4-H
UT6-H
FOR USE ON COPPER AND ALUMINUM CABLE ONLY. NOT TO BE USED ON STEEL OR ACSR CABLE.
CABLE SLICER COMPONENT PARTS
INSULATING COVERS FOR THE AREA WHERE BLADES AND HANDLES ARE JOINEDARE AVAILABLE. PLEASE CONSULT THE FACTORY.
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
126
Joint CompoundsHM-53 General Purpose Compound
HM-56 Compound
A superior compound for universal use in making aluminumcompression connections.
Compatible with all cable insulating compounds and materials,including rubber and paper.
Stable over a wide temperature range: -40° to 300°F.
Seals out air and moisture, is non-toxic and non-flammable.
For use with insulated high voltage connections.
A compression joint compound for aluminum cable connectionswhich is fully compatible with all synthetic solid insulatingmaterials, including paper insulation and impregnating oils.
Temperature range: -40° to 300°F.
Effectively lowers contact resistance of compression joint.
Seals out moisture, is non-toxic and non-flammable.
HM-53 compound includes fine zinc particles suspended in a synthetic base vehicle.Under installing pressure the zinc particles develop a bridge between conductor andconnector to provide multiple low resistance contact points. HM-53 also protectsconnections from intrusions of moisture and contaminants.
The operating range of -40° to 300°F. makes it useful in both the high and low temperature ranges.
In making cable connections, simply coat cable strands with compound and brush toabrade surfaces through compound. Work compound down in between strands. Insertcoated cable into connector and tighten or compress joint.
For pad-to pad connections coat mating surfaces before tightening bolts.
Designed for high voltage applications where insulation is nearby and might possibly come in contact with the compound for extended periods of time.
High lubricity base combined with metallic additives produces low contact resistance joints.
Mixture of hard, fine zinc and silicon carbide particles suspended in a high temperaturesynthetic base break through oxide films to expose fresh metal surfaces.
Oxide inhibitors protect against further oxidation by sealing out air and moisture.
Simply coat conductor with compound from squeeze bottle and brush or abradesurfaces through compound. Work compound down in between strands. Insert coatedconductor into connector and make compression joint. Remove excess compound.
HM-56 is a compression joint compound. It is not fro use between flat bolted surfaces,nor between flat threaded parts. For this application use HM-53 described above.
•
•
••
••
•••
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497
Miscellan
eou
s
VIEW CATALOGNUMBER HEIGHT MATERIALWIDTH
WL3-12
WL3.5-16
3"
3-1/2"
12"
16"
GRAYVIRGIN
PVC
WLP-10T
WLP-10T 18-1.5
11"
21-5/8"2-11/16"
WLP-11S 11-1/4" 3"
WLP- CSP
WL- 6137
SQG-1212
8-3/4" 11-1/8"
21" 16-1/2"
14-3/4" 14-3/4"HIGH DENSITY
BLACKPOLYETHYLENE
127
WildlifeProtectors
Protect wildlife, prevent interrupted service and lostrevenue.
Easy to install, and they are reusable.
WL Series are precision molded in virgin PVC.
•
••
The Homac Companies12 Southland Road
Ormond Beach, FL 32174Phone: 904/677-9110 Fax: 904/673-5497