HOMELINE® Circuit Breakers01358750,751,911

Square D

www.squared.comFOR CURRENT INFORMATION

HOM

AmpereRating^

One Pole -120/240 Vac

Catalog Number Price

TWo Pole -120/240 VacCommon Trip

Catalog Number Price10,000 Amperes RMS - UL Listed Interrupting Rating

•"• 15K l̂ 20Efl 25Km so•£• 35•EH 40

H 45KB 5°KH 60HHI 70K3 so••1 90••1 1°°••1 110B l̂ 125

HOM1154AHOM120«AHOM125*HOM130*

HOM140*

HOM150*

$17.5017.5017.5017.50

17!50

17]SO

HOM215*HOM220*HOM225*HOM230*HOM235*HOM240*HOM245*HOM250*HOM260*HOM270*HOM280»HOM290*HOM2100*HOM2110*HOM2125*

$ 40.3040.3040.3040.3040.3040.3040.3040.3040.3082.00

112.00112.00112.00246.00246.00

HOM-GFIHOM-GF1 circuit breakers provide overload and short circuit protection, combined with Class Aground fault protection. Class A denotes a ground fault circuit interrupter that will trip when a faultcurrent to ground is 6 milliamperes or more.

AmpereRatingA

HOMELINE Circuit BreakersWith Ground Fault Circuit Interrupter

One Pole -120 Vac1 Space Required

Catalog Number Price

Two Pole - Common Trip 120/240 Vac2 Spaces Required

Catalog Number Price10,000 AIR

1520304050

HOM115GFIHOM120GFI

$141.00141.00

HOM215GFIHOM220GFIHOM230GFIHOM240GFIHOM250GFI

$275.00275.00275.00275.00275.00

HOMTTandem Circuit Breakers

Ampere Rating'One Pole Tandem - 1 20/240 Vac (One Space Required)

Catalog No. Price10,000 AIR

15 and 1515 and 2020 and 2030 and 1530 and 20

HOMT1515*HOMT1520*HOMT2020*HOMT3015*HOMT3020*

$34.9034.9034.9034.9034.90

HOMT Quad Tandem Circuit BreakersAmpere Rating" Two Pole Tandem - 1 20/240 Vac (Two Spaces Required)

1P | 2P Catalog No. j Price10,000 AIR

(2)152)15

(2) 15(2)15(2)15(2)15(2)202 20

(2)20(2)20(2)20

152025X40502025304050

HOMT1 515215*HOMT1515220*HOMT1515225*HOMT1 515230*HOMT1515240*HOMT1515250*HOMT2020220*HOMT2020225*HOMT2020230*HOMT2020240*HOMT2020250*

$76.0076.0076.0076.0076.0076.0076.0076.0076.0076.0076.00

Typical catalog number (e.g. HOMT 1515230) represents two single pole, outer poles (two 15A1P CBs) and one 2-Pole inner breaker with common trip (one 30 A 2P CB).

SURGEBREAKER1" Secondary Surge Arrester. Description

Plug-on secondary surge arrester. 1 75 Vac max.

Catalog No. Price

$1 06.00V

Circuit Breaker Wire Sizes

Breaker Type

HOM1 Pole

HOM2-Pole

HOMT and QuadQuad Only

HOM-GFI -1 -PoleHOM-GFI - 2-Pole

Ampere Rating

15-3040-5015-3035-7080-12515-3040-5015-2015-50

Wire Size (AWG)Aluminum

#14-8#8-2

#14-8#8-2

#4-2/0#14-8#6-#12#14-10#12-4

Copper(2)#14-10

#8-2

#14-8 or (2) #14-10#8-2

#4-2/0#14-8#6-#14#14-10#14-6

HOMELINE is a Registered Trademark of Square D Company or related companies.

©2000 Square D

Plug-On Circuit Breakers - UL Listed 10,000 AmperesRMS Symmetrical Interrupting Rating (AIR)

HOM One Pole HOM Two Pole HOMT One Pole HOMT Quad BreakerTandem

1 Space Required 2 Spaces Required 1 Space Required 2 Spaces Required

HOM One PoleAFI

(Arc Fault CircuitInterrupter)

HOM One Pole GFI(With GroundFault CircuitInterrupter)

HOM Two Pole GFI(With Ground FaultCircuit Interrupter)

HOMSURGEBREAKER

Surge Arrester

2 Spaces Required 2 Spaces Required

HOM-AFI HOMELINE Arc Fault Circuit Interruptersnwivi «n (10]00oAlR)

Ampere Rating1520

Poles 120 Vac11

Catalog NumberHOM115AFIHOM120AFI

Price$150.00

150.00

AccessoriesDescription

HANDLE ATTACHMENTSHandle Tie: Converts any two adjacent 120/240 Vac

single HOM breakers to independent trip

Handle Tie: Converts any two adjacent 120/240 Vacsingle pole side-by-side HOMT breakers to independent

Handle Padlock Attachment: For padlocking one poleStandard HOM breakers in "ON" or "OFF position. ..........

Handle Padlock Attachment: For padlocking two poleStandard HOM breakers in "ON" or "OFF position ...........

Handle Padlock Attachment: For padlocking centerpoles of Homeline Quad breakers in "OFF position. .........

SUB-FEED LUGS1 25 Ampere two pole plug-on -2 spaces required ...............

FILLER PLATESFills opening in covers if twistout is removed in error ............

Fills main breaker opening in convertible load centers50-125A .................................................................................

NEUTRAL LUGS

Field installed for #14 to 2/0 AI/Cu wire ..................................

MISCELLANEOUSRetaining Kit:

Secures circuit breaker to interior when used as a back-fedmain. For HOM6-12L100F/S. RB load centers. .............

Secures ONE circuit breaker right side of interior whenused as a back-fed main. For 100-125 ampereconvertible main load centers, Series S01 and S02.......

Secures ONE circuit breaker right side of interior whenused as a back-fed main. For 150-225 ampereconvertible main load centers, Series S01 and S02.......

Lock Kit: Use with convertible indoor load center covers(Series S-1). .........................................................................

Catalog No.

HOM1PA

HOM2PL

HOMQPA

HOML2125

HOMFP

QOM1FP

LK70ANLK100ANLK125AN

HOM1RK

HOM4RK2LA

HOM4RK2HA

PK6FL

Price

$ 2.201-

6.30t

6.30t

6.30

30.20T

2.00T

12.90+

6.4006.900

14.000

4.1 Ot

9.30t

9.301-

59.00+

1-10 All Rights Reserved DE3D tDE3C oDE3B vDE1B *DE3A

A 15-30 Ampere breakers are suitable for use with 60°C or 75*C conductors. 40-125 Amperebreakers are suilable for use with 75°C conductors.

A UL Listed as SWD (switching duty) rated. Suitable for switching 120 Vac fluorescent lightingloads.

* UL Listed as HACR type for use with air conditioning, heating and refrigeration equipmenthaving motor group combinations and marked for use with HACR type circuit breakers.

• 15-20 Ampere one pole tandem breakers are suitable for use with 60°C or 75°C conductors.15-30 Ampere two pole tandem breakers are suitable for use with 75°C conductors.

DiscountSchedule 3/00

Page 2: HOMELINE® Circuit Breakers 01358750,751,911 · PDF fileSecures circuit breaker to interior when used as a back-fed ... Secures ONE circui t breake r righ side of interio ... Molded

Selection InformationClass 500, 600

Square D

www.squared.comFOR CURRENT INFORMATION

HOM Circuit Breakers QO Circuit Breakers

Plug-on HOM-GFI HOMT QO QO-H QO-VH QH QOT QO-GFI QO-VHGFI

BreakerType QOB QOB-H QOB-VH QHB QOB-GFI QOB-VHGFI

QOU* QOU-H

Number of Poles 2,3*

Current Range 15-50 15-200 15-20 15- 15-50 10-100 10-50

ID-100 15-100 15-30 15-30 15-

12515-100 150 30 30 30 15-30

Interrupting Ratings

UL/CSA

(50/60 Hz AC)a

IEC 947-2*(50/60 Hz AC)

120 Vac

120/240 Vac

240V3CT

277 Vac

480Y/277 Vac

125VdC

IEC

Hating)

10

10

10

10

10 10

10

10

10

10

10

5*

5*

10

10

10

10

5*

10

10

10

10

22

22

22

22

22

22

22

22

22

22

65

65

65

65

10

10

10 10

10

22

Special Ratings

Fed. Specs W-C-375B/GEN

Other Standard

. . .

HACR A MOM

. . .

HACR A

S

HACRt NOW HACRt

/

HACRt

/ / /

NOW

Accessories and Modifications

Shunt Trip

Auxiliary Switches

Alarm Switch

Handle Padlock Attachment / J /

/•

/•

/

/•

/•

/•

/

/•

/•

/•

/

/•

/•

/•

/

/•

/•

/•

/

/•

/•

/

/•

/•

/•

/

/•

/•

/•

/

/•

/•

/•

/

/•*

/•t

/•*

/

/•

/•

/•

/

/•

/•

/•

/

/•

/•

/•

/

/•

/•

/

/•

/•

/

/•

/•

/

Trip System Type

Thermal-Magnetic

Molded Case Switch

Dimensions(1P Unit Mount)

Height IN (mm)

Width IN (mm)

Depth IN (mm)

Pages (Unit Mount)/(l-LINE)

/ / / / /

3.13(79)

1.00(25)

2.98 (76)

Page 1-20

/

/

/

/

/

/

/ / / / / / / / / / / / /

3.5 (89)

0.75(18)

2.92 (74)

Pages 1 -2, 6-42. 6-43. 8-10, 8-1 1

A HACR on HOM 1 -Pole 15-50 A and 2-Pole 15-125 A« QO/QOB1-Pole 10-70 AT See Supplemental Digest for 3 phase corner grounded systems.•fc See Supplemental Digest for circuit breakers with IEC ratings.• Factory installed option only• QOU UL Listed for 60 VDC per pole 80-100 A, 1- and 2-Pole. and 70-100 A. 3-Pole.t HACR on QO. QOB 1 -Pole 15-70 A, 2-Pole 15-125 A, 3-Pole 15-100 A; QOU 1 -Pole and 3-Pole 15-100 A. 2-pole 15-125 A; QOB-VH 1 -Pole 15-70 A, 2-Pole 15-125 A, 3-Pole 15-100 A* Factory installed accessories are not available on QOB-VH 2-Pole 150 A and 3-Pole 110-150 Aa GFI Products are rated 60Hz only.* QYU Supplemental Protectors only.* 1 and 2-pole, 10-70 A and 3-pole 10-60 A only.« See Page 6-45 for dimensions for: QOB2150VH, QOB3110VH, QOB3125VH and QOB3150VH.e HOMT Tandem is 30 A maximum. HOMT Quad Tandem has 20 A maximum on outside poles, and 50 A maximum on the inside poles.

QO and I-LINE are Registered Trademarks of Square D Company or related companies.

©2000 Square D6-2 All Rights Reserved 3/00


Top Related