Product: Multi-element Standard Solution
Lot N: R42710 Art.No.: 2647.1
Composition: As 1mg/l; Be 1mg/l; Bi 1mg/l; Ca 1mg/l; Cd 1mg/l; Co 1mg/l; Cr 1mg/l; Cu 1mg/l; Fe 1mg/l; Li 1mg/l; Mg 1mg/l; Mn 1mg/l; Mo 1mg/l; Ni 1mg/l; Pb 1mg/l; Sb 1mg/l; Se 1mg/l; Sr 1mg/l; Ti 1mg/l; Tl 1mg/l; V 1mg/l; Zn 1mg/l;
Matrix: 5% HNO3
ElementCertified Valueand uncertainty
(mg/l)*
Starting MaterialPurity
LOT Number Starting Solution Traceability
As 1.002 ± 0.007 As 99.9999% 10/[10] : As[As] : 2N : T- : 5 : G08-02 NIST SRM 3103aLot N 010713
Be1.005 ± 0.007
BeO 99.95%10/[10] : Be[BeO] : 5N1F : T- : 5 : G02-03
NIST SRM 3105aLot N 892707
Bi 0.997 ± 0.007 Bi 99.999% 10/[10] : Bi[Bi] : 10N : T- : 5 : E02-04 NIST SRM 3106Lot N 991212
Ca1.000 ± 0.004 CaCO
3 99.999+% 10/[10][20] : Ca[CaCO3] : 2N : T- : 5 :
H09-02-02NIST SRM 3109aLot N 000622
Cd 0.998 ± 0.005 Cd 99.999% 10/[10] : Cd[Cd] : 5N : T- : 5 : H01-04 NIST SRM 3108Lot N 890312
Co 0.997 ± 0.006 Co 99.999% 10/[10] : Co[Co] : 5N : T- : 5 : H04-02 NIST SRM 3113Lot N 000630
Cr0.997 ± 0.006 Cr(NO
3)
3 99.999% 1/[1] : Cr[Cr(NO3)3] : 2N : T- : 5 :
H03-02NIST SRM 3112aLot N 990607
Cu 1.001 ± 0.005 Cu 99.999% 10/[10] : Cu[Cu] : 2N : T- : 5 : H01-03 NIST SRM 3114Lot N 011017
Fe 0.996 ± 0.007 Fe 99.998% 10/[10] : Fe[Fe] : 5N : T- : 5 : H03-02 NIST SRM 3126aLot N 000606
Li 0.997 ± 0.008 LiNO3 99.999% 10/[10] : Li[LiNO3] : 5N : T- : 5 : G11-02 NIST SRM 3129a
Lot N 000505
Mg1.000 ± 0.007 Mg(NO
3)
2 99.999% 10/[10] : Mg[Mg(NO3)2] : 2N : T- : 5 :
G03-02NIST SRM 3131aLot N 991107
Mn 0.999 ± 0.004 Mn 99.99% 10/[10] : Mn[Mn] : 5N : T- : 5 : G04-02 NIST SRM 3132Lot N 890903
Mo 0.996 ± 0.009 Mo 99.99% 10/[10] : Mo[Mo] : 5N4F : T- : 5 : F02-05 NIST SRM 3134Lot N 891307
Ni 0.997 ± 0.006 Ni 99.996% 10/[10] : Ni[Ni] : 5N : T- : 5 : G05-02 NIST SRM 3136Lot N 000612
Pb1.000 ± 0.004 Pb(NO
3)
2 99.9995% 10/[10] : Pb[Pb(NO3)2] : 5N : T- : 5 :
H01-02NIST SRM 3128Lot N 991504
Sb 1.000 ± 0.005 Sb 99.999% 20 : Sb[Sb] :5N2F : T- : 5 : H01 NIST SRM 3102aLot N 990707
Se 0.996 ± 0.009 Se 99.999% 10/[10] : Se[Se] : 5N : T- : 5 : F03-03 NIST SRM 3149Lot N 992106
Sr0.993 ± 0.006 Sr(NO
3)
2 99.999% 10/[10] : Sr[Sr(NO3)2] : 5N : T- : 5 :
H04-03NIST SRM 3153aLot N 990906
1/2International Chemical Process sarl
1, rue Clapeyron – 75008 ParisTel: 01.74.90.26.36 – Fax 01.73.72.31.84 – Email: [email protected] – Web: http://www.spectracer.eu
Ti0.999 ± 0.007 (NH
4)
2TiF
6 99.999% 10/[10] : Ti[(NH4)2TiF6] : 5N1F : T- : 5 :
G03-04NIST SRM 3162aLot N 992801
Tl 0.997 ± 0.008 TlNO3 99.9% 1/[1] : Tl[TlNO3] : 2N : T- : 5 : H04-02 NIST SRM 3158
Lot N 993012
V0.999 ± 0.006
V 99.99%10/[10][50] : V[V] : 5N : T- : 5 : G01-05-03
NIST SRM 3165Lot N 992706
Zn 1.005 ± 0.008 Zn 99.99% 10/[10] : Zn[Zn] : 5N : T- : 5 : H03-03 NIST SRM 3168aLot N 001402
* the certified value is based on both gravimetric preparation, and instrumental analysis * the uncertainty is calculated as: U=ku
c,
where k is the multiplier for a 95% level of confidence interval (Table B.1 of Guidelines for Evaluating and
Expressing the uncertainty of NIST measurement results), and uc is the combinated standard uncertainty calculated acc. ISO Guide to the Expression of
Uncertainty in Measurement
Measured density: 1.021 g/cm3 at 20 0C
This solution was manufactured using purified acids by subboiling, 18 MOhm double deionised water, calibrated Class A glassware, and high density polyethylene bottle, decontaminated by leaching with high purity acids, 18 MOhm deionised water and triple rinse. Balances are calibrated with weights, traceable to NIST. Stability and accuracy are guaranteed until the date shown at the label provided that the solution is tightly capped and stored under normal laboratory conditions.This certification is nullified if the standard solution is damaged, contaminated, or modified.
Certification date:Shelf Life* :Expiry date** :
02.07.2009until 08.2010………………(Should not exceed 6 months from date of opening within the shelf-life period.)
* The shelf life is the specified length of time prior to use for which a properly packaged and stored standard solution remains within the specified uncertainty.
** The expiry date is the date after which the certification of standard solution becomes invalid (due to evaporation losses and frequent use).
2/2International Chemical Process sarl
1, rue Clapeyron – 75008 ParisTel: 01.74.90.26.36 – Fax 01.73.72.31.84 – Email: [email protected] – Web: http://www.spectracer.eu