ICL-LEDG2-2MB G2 Recessed Multiple (2) Head - Gen 2
Ceiling Cut Out: 6 1/4” x 11 7/16”Horizontal Adjustability: 360°Verical Adjustability: 30°
10 1/4”11 3/4”
30° 30°
6 5/8”1 3/4”
13 1/2”
13 1/8”
5” 6 1/2”
DESCRIPTIONMultiples series is designed for easy installation and fixture maintenance, with all parts and components accessible from below the ceiling. All lamp holders are adjustable 360° horizontal and 30° vertical for spot lighting in multiple directions. The LED series is offered with a new construction frame and 1, 2, 3, or 4 lamp configurations.
LED LIGHT ENGINE ■ 92 CRI & 82 CRI in 2700K, 3000K, 3500K and 4100K with 2 SDCM binning
■ LED mounted to die-cast / extruded aluminum heat sink ■ >50,000 hours average rated life at 70% output
OPTICS16˚ Spot, 24° Narrow Flood, 32˚ Flood and 50˚ Wide Flood
ELECTRICAL ■ Multiple dimming drivers available ■ 120V or 277V input; Power factor >.9, 50/60Hz ■ This product complies with IEEE C62.41 for surge endurance up to 2.5KV. Additional surge protection recommended. Damage from power surge is not covered by warranty.
HOUSINGThe luminaire is type Non-IC. Insulation must be kept at a minimum of 3” away from fixture. The housing is constructed of 22GA steel powder coated black. The internal wire bundles are locked and covered with a glass sleeve. The housing is supplied with a plate to allow the junction box to be accessible from below the ceiling.
MOUNTINGThe luminaires can accommodate a ½” to 1 3/4” ceiling thickness. The fixture is supplied with channel brackets that allow up-to 5” vertical adjustment. Compatible with C-channel, flat bar, wood joist bar and EMT. Bar hangers must be ordered separately. C-channel are recommended for T-bar ceilings. Wood joist bar hangers are not for use in T-bar ceilings.
FLANGED TRIMExtruded trim frame includes torsion springs for convenient installation or removal from the housing.
EMERGENCYRemote or integral test switch included. External battery operates one LED load of up to 7W at a minimum of 600 lumens for 90 minutes. Integral test switch adds 2” to the depth of luminaire.
ACCESSORIESLuminaire will accommodate (2) Filter Media per head, no accessory holder is required.
LISTING/WARRANTY ■ ETL listed to US and Canadian standards for damp locations. ■ 5-Year Intense LED Limited Warranty
Notes: 1. Consult factory for lead times2. Dimming available in 120V3. DMX512 RDM available with L3 & L4 only4. Access above ceiling required5. EM7T adds 2” depth6. White exterior, black interior
Filters for 16° optic
PFL-CL1-S16 (Prismatic Spread Lens)PFL-CL2-S16 (Linear Spread Lens)PFL-CL4-S16 (Soft Focus Lens)
Filters for 24°, 32° & 50° optic
PFL-CL1-S (Prismatic Spread Lens)PFL-CL2-S (Linear Spread Lens)PFL-CL4-S (Soft Focus Lens)
Louver & Snoot for 16° optic
PFLMB-16 (Hex Louver)SNTR16 (Black Snoot)SNTR16W6 (White Snoot)
Louver & Snoot for 24°, 32° & 50° optic
PFLMB (Hex Louver)SNTR (Black Snoot)SNTRW6 (White Snoot)
Trim Example: ICL-LEDG2L330-2-BW-24
Luminaire System Wattage CCT / CRI Driver Voltage Finish Optic Option
ICL-LEDG2 L1 (20W)L2 (28W)L3 (40W)L4 (58W)
27-2 (2700K / 82 CRI)279-2 (2700K / 92 CRI)30-2 (3000K / 82 CRI)309-2 (3000K / 92 CRI)35-2 (3500K / 82 CRI)359-21 (3500K / 92 CRI)41-2 (4100K / 82 CRI)419-21 (4100K / 92 CRI)
blank (Non-Dimming)-DELV2 (ELV Dimming)-D10 (0-10V Dimming 10%)-ED10V1 (eldoLED 0-10V 1%)-ED10V01 (eldoLED 0-10V 0.1%)-LUT (Lutron® LDE1 EcoSystem 1%)-LUT22 (Lutron® LTEA2W 2-Wire 1%)-DMXR3 (DMX512 RDM 0.1%)
blank (120V)27 (277V)
-BW (Black Interior / White Trim)-WW (White Interior / White Trim)
-16 (16° SP)-24 (24° NFL)-32 (32° FL)-50 (50° WFL)
I100 (C-Channel Bar Hangers)I200 (Flat Bar Bar Hangers)I400 (Wood Joist Bar Hangers)EM74 (7W Emergency Backup w/ Remote Test Switch IOTA part #ILB-CP07-A)EM7T4, 5 (7W Emergency Unit w/Integral Test Switch IOTA part #ILB-CP07-R)
ELECTRICAL DATA
LED Light Engine Wattage Per Head 1 CCT / CRI Nominal Delivered Lumens 2, 3
L1L2L3L4
10W14W20W29W
3000K / 82 CRI3000K / 82 CRI3000K / 82 CRI3000K / 82 CRI
1100lm1500lm2000lm2600lm
1 System Wattage includes driver and LED Module consumption2 Delivered lumens will vary depending on CCT, CRI and optic3 Data shown is per individual head
JOB NAME
CATALOG NUMBER
NOTES TYPE
MB-MULTIPLES L/M-0515:19 P-2
INTENSE LIGHTING | 3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883For Intense Lighting’s limited product warranty, go to www.intenselighting.com. For a printed copy of the warranty, you may call 800 961-5321.© 2019 Intense Lighting, LLC. All rights reserved. Note: This document is subject to change without notice.
ICL-LEDG2L130-1Report #: ILL-08232016-03.3 (-16) ILL-08232016-02.3 (-24) ILL-08232016-01.3 (-32) ILL-08232016-05.3 (-50)
APPLICATION DATA:
W and L are the outer points where the candle power drops to 50% of maximum. FC are the initial foot candles at the center of the beam.
W Beam widthL Beam lengthC Distance to center of beamD DistanceFC Footcandles
Illuminated width & length are based upon point at which illuminance falls to 50% of center illuminance. Recommended spacing is based upon uniform illuminance aiming angle is the angle between the lamp axis and the perpendicular to the illuminated plane.
0° HORIZONTAL 30° HORIZONTAL 30° VERTICAL
D FC W L D C FC W L D C FC W L
ICL-LEDG2L130-1-163000K / 16° Spot
Per Head
6’8’
10’12’
23813485.659.5
1’ 7”2’ 2”2’ 8”3’ 4”
1’ 7”2’ 2”2’ 8”3’ 4”
6’8’
10’12’
3’4’5’7’
15285.654.838.2
2’ 4”2’ 11”3’ 8”4’ 4”
1’ 9”2’ 6”3’ 2”3’ 9”
3’4’5’6’
5’6’8’10’
21412079.553.6
1’ 6”2’ 1”2’ 7”3’ 3”
3’ 1”4’
4’ 9”5’ 11”
ICL-LEDG2L130-1-243000K / 24° Narrow Flood
Per Head
6’8’
10’12’
86.648.731.221.6
3’4’5’6’
3’4’5’6’
6’8’
10’12’
3’4’5’6’
58.633
21.114.7
3’ 8”4’ 10”
6’7’ 3”
3’ 4”4’ 4”5’ 4”6’ 5”
3’4’5’6’
4’6’7’9’
8146.930
20.8
2’ 9”3’ 6”4’ 4”5’ 3”
4’ 6”5’ 11”7’ 4”8’ 9”
ICL-LEDG2L130-1-323000K / 32° Flood
Per Head
6’8’
10’12’
71.740.325.817.9
3’ 7”4’ 10”
6’7’ 4”
3’ 7”4’ 10”
6’7’ 4”
6’8’
10’12’
3’4’4’5’
50.128.218.312.8
4’ 2”5’ 7”6’ 11”8’ 2”
3’ 9”5’ 1”6’ 2”7’ 5”
3’4’5’6’
4’5’6’8’
75.742.927
18.9
3’3’ 9”4’ 11”5’ 10”
4’ 8”6’ 1”7’ 8”9’ 2”
ICL-LEDG2L130-1-503000K / 50° Wide Flood
Per Head
6’8’
10’12’
42.624
15.310.6
6’ 4”8’ 5”10’ 6”12’ 7”
6’ 4”8’ 5”10’ 6”12’ 7”
6’8’
10’12’
2’3’4’4’
31.717.911.47.9
5’ 6”7’ 2”8’ 11”10’ 9”
5’ 5”7’ 3”9’ 1”
10’ 11”
3’4’5’6’
3’4’6’7’
48.127
17.512.2
4’ 1”5’ 5”6’ 9”8’ 1”
5’ 3”6’ 10”8’ 7”10’ 2”
WL
FC
D
L
W
D
C
30°
FC
D
LC W
30°
Photometric Data shown is compiled per head. For multi-light photometrics consult factory.
CCT / CRI Multipliers: 2700K / 82 CRI (x 0.96) 2700K / 92 CRI (x 0.8) 3000K / 82 CRI (x 1.00) 3000K / 92 CRI (x 0.83) 3500K / 82 CRI (x 1.03) 3500K / 92 CRI (x 0.86) 4100K / 82 CRI (x 1.04) 4100K / 92 CRI (x 0.89)
768
1152
1537 10° 20°
Watts: 9.8Lumens: 1112 LPW: 113 CCT: 3000K
Candelas at Nadir
Degree Candela
0°5°15°25°35°45°
15331494122488526735
Candelas at Nadir
Degree Candela
0°5°15°25°35°45°
85616476118445821415
2140
4231
6421
8561 10°
80°
70°
60°
50°
40°
30°20°
16° Spot (16)
Watts: 9.8Lumens: 1229 LPW: 125 CCT: 3000K
Candelas at Nadir
Degree Candela
0°5°15°25°35°45°
31162785143966511613
779
1558
2337
3116 10°
80°
70°
60°
50°
40°
30°20°
24° Narrow Flood (24)
Watts: 9.8Lumens: 1056 LPW: 108 CCT: 3000K
50°
40°
645
1280
1936
2581 10° 20°
32° Flood (32)
Watts: 9.8Lumens: 1082 LPW: 110 CCT: 3000K
Candelas at Nadir
Degree Candela
0°5°15°25°35°45°
25812498151768813914
80°
70°
60°
50°
40°
30° 30°
50° Wide Flood (50)
38480°
70°
60°
Emergency Multiplier: 7W Emergency (x 0.71)
JOB NAME
CATALOG NUMBER
NOTES TYPE
MB-MULTIPLES L/M-0515:19 P-9
INTENSE LIGHTING | 3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883For Intense Lighting’s limited product warranty, go to www.intenselighting.com. For a printed copy of the warranty, you may call 800 961-5321.© 2019 Intense Lighting, LLC. All rights reserved. Note: This document is subject to change without notice.
ICL-LEDG2L230-1Report #: ILL-08232016-03.2 (-16) ILL-08232016-02.2 (-24) ILL-08232016-01.2 (-32) ILL-08232016-05.2 (-50)
APPLICATION DATA:
W and L are the outer points where the candle power drops to 50% of maximum. FC are the initial foot candles at the center of the beam.
W Beam widthL Beam lengthC Distance to center of beamD DistanceFC Footcandles
Illuminated width & length are based upon point at which illuminance falls to 50% of center illuminance. Recommended spacing is based upon uniform illuminance aiming angle is the angle between the lamp axis and the perpendicular to the illuminated plane.
0° HORIZONTAL 30° HORIZONTAL 30° VERTICAL
D FC W L D C FC W L D C FC W L
ICL-LEDG2L230-1-163000K / 16° Spot
Per Head
6’8’
10’12’
32518311781.2
1’ 7”2’ 2”2’ 8”3’ 4”
1’ 7”2’ 2”2’ 8”3’ 4”
6’8’
10’12’
3’4’5’7’
20811774.852.2
2’ 4”2’ 11”3’ 8”4’ 4”
1’ 9”2’ 6”3’ 2”3’ 9”
3’4’5’6’
5’6’8’10’
29316410973.2
1’ 6”2’ 1”2’ 7”3’ 3”
3’ 1”4’
4’ 9”5’ 11”
ICL-LEDG2L230-1-243000K / 24° Narrow Flood
Per Head
6’8’
10’12’
11866.542.629.6
3’4’5’6’
3’4’5’6’
6’8’
10’12’
3’4’5’6’
8045
28.820
3’ 8”4’ 10”
6’7’ 3”
3’ 4”4’ 4”5’ 4”6’ 5”
3’4’5’6’
4’6’7’9’
11164.140.928.5
2’ 9”3’ 6”4’ 4”5’ 3”
4’ 6”5’ 11”7’ 4”8’ 9”
ICL-LEDG2L230-1-323000K / 32° Flood
Per Head
6’8’
10’12’
97.955.135.324.5
3’ 7”4’ 10”
6’7’ 4”
3’ 7”4’ 10”
6’7’ 4”
6’8’
10’12’
3’4’4’5’
68.538.525
17.4
4’ 2”5’ 7”6’ 11”8’ 2”
3’ 9”5’ 1”6’ 2”7’ 5”
3’4’5’6’
4’5’6’8’
10358.736.925.8
3’3’ 9”4’ 11”5’ 10”
4’ 8”6’ 1”7’ 8”9’ 2”
ICL-LEDG2L230-1-503000K / 50° Wide Flood
Per Head
6’8’
10’12’
58.232.720.914.5
6’ 4”8’ 5”10’ 6”12’ 7”
6’ 4”8’ 5”10’ 6”12’ 7”
6’8’
10’12’
2’3’4’4’
43.324.515.610.8
5’ 6”7’ 2”8’ 11”10’ 9”
5’ 5”7’ 3”9’ 1”
10’ 11”
3’4’5’6’
3’4’6’7’
65.736.923.916.6
4’ 1”5’ 5”6’ 9”8’ 1”
5’ 3”6’ 10”8’ 7”10’ 2”
WL
FC
D
L
W
D
C
30°
FC
D
LC W
30°
Photometric Data shown is compiled per head. For multi-light photometrics consult factory.
1049
1574
2099 10° 20°
Watts: 13.7Lumens: 1519 LPW: 111 CCT: 3000K
Candelas at Nadir
Degree Candela
0°5°15°25°35°45°
209420401671120936448
Candelas at Nadir
Degree Candela
0°5°15°25°35°45°
116938845161762529221
2923
5847
8770
11693 10°
80°
70°
60°
50°
40°
30°20°
16° Spot (16)
Watts: 13.7Lumens: 1678 LPW: 123 CCT: 3000K
Candelas at Nadir
Degree Candela
0°5°15°25°35°45°
42563804196590915817
1064
2128
3192
4256 10°
80°
70°
60°
50°
40°
30°20°
24° Narrow Flood (24)
Watts: 13.7Lumens: 1442 LPW: 105 CCT: 3000K
50°
40°
881
1763
2644
3525 10° 20°
32° Flood (32)
Watts: 13.7Lumens: 1478 LPW: 108 CCT: 3000K
Candelas at Nadir
Degree Candela
0°5°15°25°35°45°
35253389207294019019
80°
70°
60°
50°
40°
30° 30°
50° Wide Flood (50)
52580°
70°
60°
CCT / CRI Multipliers: 2700K / 82 CRI (x 0.96) 2700K / 92 CRI (x 0.8) 3000K / 82 CRI (x 1.00) 3000K / 92 CRI (x 0.83) 3500K / 82 CRI (x 1.03) 3500K / 92 CRI (x 0.86) 4100K / 82 CRI (x 1.04) 4100K / 92 CRI (x 0.89)
Emergency Multiplier: 7W Emergency (x 0.51)
JOB NAME
CATALOG NUMBER
NOTES TYPE
MB-MULTIPLES L/M-0515:19 P-10
INTENSE LIGHTING | 3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883For Intense Lighting’s limited product warranty, go to www.intenselighting.com. For a printed copy of the warranty, you may call 800 961-5321.© 2019 Intense Lighting, LLC. All rights reserved. Note: This document is subject to change without notice.
ICL-LEDG2L330-1Report #: ILL-08232016-03.1 (-16) ILL-08232016-02.1 (-24) ILL-08232016-01.1 (-32) ILL-08232016-05.1 (-50)
APPLICATION DATA:
W and L are the outer points where the candle power drops to 50% of maximum. FC are the initial foot candles at the center of the beam.
W Beam widthL Beam lengthC Distance to center of beamD DistanceFC Footcandles
Illuminated width & length are based upon point at which illuminance falls to 50% of center illuminance. Recommended spacing is based upon uniform illuminance aiming angle is the angle between the lamp axis and the perpendicular to the illuminated plane.
0° HORIZONTAL 30° HORIZONTAL 30° VERTICAL
D FC W L D C FC W L D C FC W L
ICL-LEDG2L330-1-163000K / 16° Spot
Per Head
6’8’
10’12’
435245157109
1’ 7”2’ 2”2’ 8”3’ 4”
1’ 7”2’ 2”2’ 8”3’ 4”
6’8’
10’12’
3’4’5’7’
27815710070
2’ 4”2’ 11”3’ 8”4’ 4”
1’ 9”2’ 6”3’ 2”3’ 9”
3’4’5’6’
5’6’8’10’
39222014698.1
1’ 6”2’ 1”2’ 7”3’ 3”
3’ 1”4’
4’ 9”5’ 11”
ICL-LEDG2L330-1-243000K / 24° Narrow Flood
Per Head
6’8’
10’12’
16291.358.540.6
3’4’5’6’
3’4’5’6’
6’8’
10’12’
3’4’5’6’
11061.839.627.5
3’ 8”4’ 10”
6’7’ 3”
3’ 4”4’ 4”5’ 4”6’ 5”
3’4’5’6’
4’6’7’9’
15288
56.239.1
2’ 9”3’ 6”4’ 4”5’ 3”
4’ 6”5’ 11”7’ 4”8’ 9”
ICL-LEDG2L330-1-323000K / 32° Flood
Per Head
6’8’
10’12’
13575.748.433.6
3’ 7”4’ 10”
6’7’ 4”
3’ 7”4’ 10”
6’7’ 4”
6’8’
10’12’
3’4’4’5’
9452.934.423.9
4’ 2”5’ 7”6’ 11”8’ 2”
3’ 9”5’ 1”6’ 2”7’ 5”
3’4’5’6’
4’5’6’8’
14280.750.735.5
3’3’ 9”4’ 11”5’ 10”
4’ 8”6’ 1”7’ 8”9’ 2”
ICL-LEDG2L330-1-503000K / 50° Wide Flood
Per Head
6’8’
10’12’
77.943.828
19.5
6’ 4”8’ 5”10’ 6”12’ 7”
6’ 4”8’ 5”10’ 6”12’ 7”
6’8’
10’12’
2’3’4’4’
57.932.820.914.5
5’ 6”7’ 2”8’ 11”10’ 9”
5’ 5”7’ 3”9’ 1”
10’ 11”
3’4’5’6’
3’4’6’7’
87.949.532
22.3
4’ 1”5’ 5”6’ 9”8’ 1”
5’ 3”6’ 10”8’ 7”10’ 2”
WL
FC
D
L
W
D
C
30°
FC
D
LC W
30°
Photometric Data shown is compiled per head. For multi-light photometrics consult factory.
1405
2108
2811 10° 20°
Watts: 20.2Lumens: 2034 LPW: 101 CCT: 3000K
Candelas at Nadir
Degree Candela
0°5°15°25°35°45°
280427322238161948865
Candelas at Nadir
Degree Candela
0°5°15°25°35°45°
1566111846216683739228
4016
8031
12047
16062 10°
80°
70°
60°
50°
40°
30°20°
16° Spot (16)
Watts: 20.2Lumens: 2248 LPW: 111 CCT: 3000K
Candelas at Nadir
Degree Candela
0°5°15°25°35°45°
584652252700124821724
1462
2923
4385
5846 10°
80°
70°
60°
50°
40°
30°20°
24° Narrow Flood (24)
Watts: 20.2Lumens: 1981 LPW: 98 CCT: 3000K
50°
40°
1211
2421
3632
4842 10° 20°
32° Flood (32)
Watts: 20.2Lumens: 2031 LPW: 101 CCT: 3000K
Candelas at Nadir
Degree Candela
0°5°15°25°35°45°
484246552846129126126
80°
70°
60°
50°
40°
30° 30°
50° Wide Flood (50)
70380°
70°
60°
CCT / CRI Multipliers: 2700K / 82 CRI (x 0.96) 2700K / 92 CRI (x 0.8) 3000K / 82 CRI (x 1.00) 3000K / 92 CRI (x 0.83) 3500K / 82 CRI (x 1.03) 3500K / 92 CRI (x 0.86) 4100K / 82 CRI (x 1.04) 4100K / 92 CRI (x 0.89)
Emergency Multiplier: 7W Emergency (x 0.35)
JOB NAME
CATALOG NUMBER
NOTES TYPE
MB-MULTIPLES L/M-0515:19 P-11
INTENSE LIGHTING | 3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883For Intense Lighting’s limited product warranty, go to www.intenselighting.com. For a printed copy of the warranty, you may call 800 961-5321.© 2019 Intense Lighting, LLC. All rights reserved. Note: This document is subject to change without notice.
ICL-LEDG2L430-1Report #: ILL-08232016-03 (-16) ILL-08232016-02 (-24) ILL-08232016-01 (-32) ILL-08232016-05 (-50)
1874
2811
3748 10° 20°
Watts: 29.3Lumens: 2713 LPW: 93 CCT: 3000K
Candelas at Nadir
Degree Candela
0°5°15°25°35°45°
373936432984215865186
Candelas at Nadir
Degree Candela
0°5°15°25°35°45°
20734157952888111652238
5220
10441
15661
20881 10°
80°
70°
60°
50°
40°
30°20°
16° Spot (16)
Watts: 29.3Lumens: 2997 LPW: 102 CCT: 3000K
Candelas at Nadir
Degree Candela
0°5°15°25°35°45°
760067933510162328231
1900
3800
5700
7600 10°
80°
70°
60°
50°
40°
30°20°
24° Narrow Flood (24)
Watts: 29.3Lumens: 2575 LPW: 88 CCT: 3000K
50°
40°
1574
3148
4721
6295 10° 20°
32° Flood (32)
Watts: 29.3Lumens: 2640 LPW: 90 CCT: 3000K
Candelas at Nadir
Degree Candela
0°5°15°25°35°45°
629560513700167934034
80°
70°
60°
50°
40°
30° 30°
APPLICATION DATA:
W and L are the outer points where the candle power drops to 50% of maximum. FC are the initial foot candles at the center of the beam.
W Beam widthL Beam lengthC Distance to center of beamD DistanceFC Footcandles
Illuminated width & length are based upon point at which illuminance falls to 50% of center illuminance. Recommended spacing is based upon uniform illuminance aiming angle is the angle between the lamp axis and the perpendicular to the illuminated plane.
50° Wide Flood (50)
93780°
70°
60°
0° HORIZONTAL 30° HORIZONTAL 30° VERTICAL
D FC W L D C FC W L D C FC W L
ICL-LEDG2L430-1-163000K / 16° Spot
Per Head
6’8’
10’12’
580326209145
1’ 7”2’ 2”2’ 8”3’ 4”
1’ 7”2’ 2”2’ 8”3’ 4”
6’8’
10’12’
3’4’5’7’
37120913493.3
2’ 4”2’ 11”3’ 8”4’ 4”
1’ 9”2’ 6”3’ 2”3’ 9”
3’4’5’6’
5’6’8’10’
523293194131
1’ 6”2’ 1”2’ 7”3’ 3”
3’ 1”4’
4’ 9”5’ 11”
ICL-LEDG2L430-1-243000K / 24° Narrow Flood
Per Head
6’8’
10’12’
21111976
52.8
3’4’5’6’
3’4’5’6’
6’8’
10’12’
3’4’5’6’
14380.451.535.7
3’ 8”4’ 10”
6’7’ 3”
3’ 4”4’ 4”5’ 4”6’ 5”
3’4’5’6’
4’6’7’9’
19811473.150.8
2’ 9”3’ 6”4’ 4”5’ 3”
4’ 6”5’ 11”7’ 4”8’ 9”
ICL-LEDG2L430-1-323000K / 32° Flood
Per Head
6’8’
10’12’
17598.463
43.7
3’ 7”4’ 10”
6’7’ 4”
3’ 7”4’ 10”
6’7’ 4”
6’8’
10’12’
3’4’4’5’
12268.844.731.1
4’ 2”5’ 7”6’ 11”8’ 2”
3’ 9”5’ 1”6’ 2”7’ 5”
3’4’5’6’
4’5’6’8’
18510565.946.1
3’3’ 9”4’ 11”5’ 10”
4’ 8”6’ 1”7’ 8”9’ 2”
ICL-LEDG2L430-1-503000K / 50° Wide Flood
Per Head
6’8’
10’12’
10458.437.426
6’ 4”8’ 5”10’ 6”12’ 7”
6’ 4”8’ 5”10’ 6”12’ 7”
6’8’
10’12’
2’3’4’4’
77.243.727.819.3
5’ 6”7’ 2”8’ 11”10’ 9”
5’ 5”7’ 3”9’ 1”
10’ 11”
3’4’5’6’
3’4’6’7’
11765.942.629.7
4’ 1”5’ 5”6’ 9”8’ 1”
5’ 3”6’ 10”8’ 7”10’ 2”
WL
FC
D
L
W
D
C
30°
FC
D
LC W
30°
Photometric Data shown is compiled per head. For multi-light photometrics consult factory.
CCT / CRI Multipliers: 2700K / 82 CRI (x 0.96) 2700K / 92 CRI (x 0.8) 3000K / 82 CRI (x 1.00) 3000K / 92 CRI (x 0.83) 3500K / 82 CRI (x 1.03) 3500K / 92 CRI (x 0.86) 4100K / 82 CRI (x 1.04) 4100K / 92 CRI (x 0.89)
Emergency Multiplier: 7W Emergency (x 0.24)
JOB NAME
CATALOG NUMBER
NOTES TYPE
MB-MULTIPLES L/M-0515:19 P-12
INTENSE LIGHTING | 3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883For Intense Lighting’s limited product warranty, go to www.intenselighting.com. For a printed copy of the warranty, you may call 800 961-5321.© 2019 Intense Lighting, LLC. All rights reserved. Note: This document is subject to change without notice.