Overall � Introduction � of � Cloud � Computing � Center � Total � building � area �
square � meters � �
![Page 3: Inspur 4th generation data center](https://reader034.vdocument.in/reader034/viewer/2022052506/55685307d8b42a73038b4f35/html5/thumbnails/3.jpg)
3 �
L m,W m,H/F m �
Overall � Introduction � of � Cloud � Computing � Center �
![Page 4: Inspur 4th generation data center](https://reader034.vdocument.in/reader034/viewer/2022052506/55685307d8b42a73038b4f35/html5/thumbnails/4.jpg)
4 � Airview �
![Page 5: Inspur 4th generation data center](https://reader034.vdocument.in/reader034/viewer/2022052506/55685307d8b42a73038b4f35/html5/thumbnails/5.jpg)
5 �
Able � to � hold � rack � cabintes �
Overall � Introduction � of � Cloud � Computing � Center �
![Page 6: Inspur 4th generation data center](https://reader034.vdocument.in/reader034/viewer/2022052506/55685307d8b42a73038b4f35/html5/thumbnails/6.jpg)
6 �
Be � able � to � hold servers � Overall � Introduction � of �
Cloud � Computing � Center �
![Page 7: Inspur 4th generation data center](https://reader034.vdocument.in/reader034/viewer/2022052506/55685307d8b42a73038b4f35/html5/thumbnails/7.jpg)
7 �
Shandong � provincial � departments �
existing � server � quantity � aboutTake � up � one � separate � module � of � the � Center �
Take � up � of � the � Center
�
Overall � Introduction � of � Cloud � Computing � Center �
![Page 8: Inspur 4th generation data center](https://reader034.vdocument.in/reader034/viewer/2022052506/55685307d8b42a73038b4f35/html5/thumbnails/8.jpg)
8 �
4th � Generation � � Cloud � Computing � Center �
Refer � to � data � center � grading � methods � of � Green � Grid �
Learn � from � 4th � generation � data � center � being � built � by � Microsoft �
Design � accords � with � TIA � 942 � TIA3 � standards � � and � some � core � indicators � �
reach � TIA4 � standards �
![Page 9: Inspur 4th generation data center](https://reader034.vdocument.in/reader034/viewer/2022052506/55685307d8b42a73038b4f35/html5/thumbnails/9.jpg)
9 �
Modularization � construction �
No � interference � design � and � high
� reliability �
Rapid � copy � and � change � on
� demand �
Reduce � complexity � and � decrease
� investment � cost �
![Page 10: Inspur 4th generation data center](https://reader034.vdocument.in/reader034/viewer/2022052506/55685307d8b42a73038b4f35/html5/thumbnails/10.jpg)
10 �
High � density: � the � power � of � � each � rack � cabinet � reaches �
![Page 11: Inspur 4th generation data center](https://reader034.vdocument.in/reader034/viewer/2022052506/55685307d8b42a73038b4f35/html5/thumbnails/11.jpg)
11 �
![Page 12: Inspur 4th generation data center](https://reader034.vdocument.in/reader034/viewer/2022052506/55685307d8b42a73038b4f35/html5/thumbnails/12.jpg)
12 �
With � computer � room � full � load, � the � power � consumption � of � IT � devices � is � kilowatt-hours. � In � most � computer � rooms, � the � power � consumption � of � IT � devices � is � close � to � that � of � refrigeration � equipments. � The � total � power � consumption � of � computer � room � is � kilowatt-hours �
Green � & � environ- � ment � friendly �
![Page 13: Inspur 4th generation data center](https://reader034.vdocument.in/reader034/viewer/2022052506/55685307d8b42a73038b4f35/html5/thumbnails/13.jpg)
13 �
It � fully � uses � natural � cold � for � of � the � time. �
It � partially � uses � natural � cold � for
� � of � the � time. �
PUE � is � reduced � to � � from � � of � the � most � data � centers.
Green � & � environ- � ment � friendly �
![Page 14: Inspur 4th generation data center](https://reader034.vdocument.in/reader034/viewer/2022052506/55685307d8b42a73038b4f35/html5/thumbnails/14.jpg)
14 �
With � full � load, � it � can � save � power �
kilowatt-hours. � �
![Page 15: Inspur 4th generation data center](https://reader034.vdocument.in/reader034/viewer/2022052506/55685307d8b42a73038b4f35/html5/thumbnails/15.jpg)
15 � ELECTRICAL � DISTRIBUTION � �
![Page 16: Inspur 4th generation data center](https://reader034.vdocument.in/reader034/viewer/2022052506/55685307d8b42a73038b4f35/html5/thumbnails/16.jpg)
16 � � Shandong � provincial � departments � one � year � power � consumption: � 21.64 � million � kilowatt-hours � Inspur � 4th � Generation � Cloud � Computing � Center � one � year � power � consumption: � 15.15 � million � kilowatt-hours � Save � power � � � � � � � � � � � � � � � � � � � � � � kilowatt-hours � per � year � Power � saving � ratio � 30% � Reduce � CO2 � discharge � amount � � � � � � � � � � � � � tons �
![Page 17: Inspur 4th generation data center](https://reader034.vdocument.in/reader034/viewer/2022052506/55685307d8b42a73038b4f35/html5/thumbnails/17.jpg)
17 �
High � rel iabi l ity �
Power � distribution � system � 2N � structure �
Refrigeration � system � N+1
� structure �
Network � system � 2N � structure �
![Page 18: Inspur 4th generation data center](https://reader034.vdocument.in/reader034/viewer/2022052506/55685307d8b42a73038b4f35/html5/thumbnails/18.jpg)
18 �
D a t a � c e n te r � c o n s t r u c t i o n � s t a n d a rd s � � � � � Learning � from � data � center � grading � methods � of � Microsoft � and � Green � Grid � and � according � to � modularization, � server � density � , �
refrigeration, � UPS � and � PUE, � the � grading � standards � of � Inspur � data � center � are � as � follows: �
No. � Indicators � 1st � generation � (Mainframe � ) �
2nd � generation � (Tower) �
3rd � generation � (Rack) �
4th � generation � � (Modularization) �
1 � Modularization � �
Customized � computer � room � environment � and � supporting � system � to � provide � service � for � mainframe �
N/A � Rack-level � modularization �
Computer � room � level � modularization �
2 � Cabinet � power � N/A � 2KW~5KW � 5KW~20KW � 3 � Cold � and � hot � air � channel � � � Mixed � � Separate � Enclosed � 4 � UPS � efficiency � � 80%~90% � 90%~94% � ≥95% �
5 � Natural � cold � use � efficiency � 0% � 0% � 20%~75% �
6 � Air-conditioner � inlet � air � temperature � 20~24℃ � 20~24℃ � 26~30℃ �
7 � Waste � heat � recycling � efficiency � � None � None � 10%~50% �
8 � Carbon � Usage � Effectiveness(CUE) � � None � Measure � � Measure � and � improve �
9 � PUE � � 2.0 � above � 1.5~2.0 � 1.1~1.5 �
![Page 19: Inspur 4th generation data center](https://reader034.vdocument.in/reader034/viewer/2022052506/55685307d8b42a73038b4f35/html5/thumbnails/19.jpg)
19 � Accord � with � state � 3 � levels � protection � requirement �
6-layer � physical � access � control �
Computer � room � area � and � dynamical � area � physically � separated �
Waterproof � and � moistureproof �
![Page 20: Inspur 4th generation data center](https://reader034.vdocument.in/reader034/viewer/2022052506/55685307d8b42a73038b4f35/html5/thumbnails/20.jpg)
20 �
� Nation-wide � unified � real-time � monitoring �
�
intelligent � monitoring � �
![Page 21: Inspur 4th generation data center](https://reader034.vdocument.in/reader034/viewer/2022052506/55685307d8b42a73038b4f35/html5/thumbnails/21.jpg)
21 � Monitor � room �
![Page 22: Inspur 4th generation data center](https://reader034.vdocument.in/reader034/viewer/2022052506/55685307d8b42a73038b4f35/html5/thumbnails/22.jpg)
22 �
Chengdu �
Jinan � �
Shanghai �
Zaozhuang � � Binzhou � �
Lanzhou � �
Changzhi � �
Erdos �
Ningb � �
Hefei � �
� Harbin �
Nanjing � �
Hainan �
Dezhou � �
Guizhou �
Jining � �
Mianyang �
Hohhot �
Zhengzhou � �
Weihai � Liaocheng � �
Zibo � �
Heze � �
Shaoshan �
Tempera-ture
� humidity �
Picture � Personnel �
Business � � Access � control �
State � monitor ing � center � and � unif ied � monitor ing �
![Page 23: Inspur 4th generation data center](https://reader034.vdocument.in/reader034/viewer/2022052506/55685307d8b42a73038b4f35/html5/thumbnails/23.jpg)
23 � Application � current � situation � and � future � �