Page 1: Intermittent Blowdown - Deaeratordeaerator.com/wp-content/uploads/2015/12/IB-Brochure.pdfModel Number Selection Series Tank In let Drain Vent INTERMITTENT BLOWDOWN EXAMPLE: I B 1 4

HS

Serie

s U

p to

350

,000

#/h

r Lo

w H

eadr

oom

INTE

RMITT

ENT B

LOW

DOW

N W/A

FTER

COOL

ER

Inte

rmitt

ent B

low

dow

n w

ith A

fter C

oole

r

Stan

dard

D

eaer

atin

g U

nits

KK AA

NN SSAA SS

CCII TT

YY DDEE AA

EE RRAA TT

OO RR

Kan

sas

City

Dea

erat

or’s

Int

erm

itten

t B

low

dow

n (IB

) S

epar

ator

S

yste

m

is

utiliz

ed

to

flash

hi

gh

tem

pera

ture

s /

pres

sure

bo

iler

blow

dow

n st

eam

s to

low

pre

ssur

e.

The

sepa

rate

d st

eam

is v

ente

d to

at

mos

pher

e or

retu

rned

to th

e de

aera

tor.

Th

e liq

uid

porti

on is

then

pas

sed

thro

ugh

an a

tem

pora

tion

whi

ch

mix

es c

old

wat

er w

ith t

he b

low

dow

n to

red

uce

the

tem

pera

ture

to

acce

ptab

le le

vels

for d

isch

arge

to d

rain

.

IB –

Inte

rmitt

ent B

lowd

own

WIT

H A

FTER

CO

OLE

R

Prin

cipl

es o

f Ope

ratio

n

A

SM

E C

ode

Sec

tion

VIII

Ves

sel

S

tain

less

Ste

el W

ear P

late

S

truct

ural

Leg

s

A

fterc

oole

r

Te

mpe

ratu

re R

egul

atin

g V

alve

S

train

er

Th

erm

omet

er

FEA

TUR

ES

1

Kan

sas

City

Dea

erat

or C

ompa

ny

6

731

Wes

t 121

st S

treet

, Ove

rland

Par

k, K

S 6

6209

Tel

(913

) 338

-211

1 F

ax (9

13) 3

38-2

144

W

ebsi

te: w

ww

.dea

erat

or.c

om E

mai

l: in

fo@

deae

rato

r.com

TC S

erie

s

Up

to 2

50,0

00 #

/hr

Tray

Uni

t M

eets

HE

I

BD

S Se

ries

Up

to 2

50,0

00 #

/hr

Tray

Uni

t M

eets

HE

I

DS

Serie

s U

p to

800

,000

#/h

r Tr

ay U

nit

Mee

ts H

EI

VS &

VT

Serie

s U

p to

800

,000

#/h

r Tr

ay U

nit

Min

imal

Pla

n A

rea

Mee

ts H

EI

HH

Ser

ies

Up

to 1

6,00

0,00

0 #/

hr

Tray

Uni

t-Mee

ts H

EI

Cop

yrig

ht ©

Jan

uary

200

4

In

term

itten

t Blo

wdo

wn

SPEC

IFIC

ATI

ON

S B

low

dow

n Se

para

tor

Furn

ish

and

inst

all a

s sh

own

on p

lans

: (

) B

oile

r Blo

w-D

own

Sep

arat

or(s

). M

odel

___

____

“ H

eigh

t ___

____

‘ In

let _

____

__ D

rain

___

____

“ V

ent

……

.Sel

ect P

late

Thi

ckne

ss 5

/16”

or 3

/8” t

hk …

…. A

SM

E C

ode

250

psig

@ 4

50 D

eg. F

……

. W/S

crew

ed, W

eld

Bev

el, o

r Fla

nged

con

nect

ions

. S

epar

ator

to h

ave

Sta

inle

ss S

teel

Stri

king

Pla

te a

t poi

nt o

f inl

et im

ping

emen

t, as

m

anuf

actu

red

by K

ansa

s C

ity D

eaer

ator

Com

pany

. Se

para

tor A

cces

sorie

s Fu

rnis

h an

d in

stal

l a s

epar

ator

w/3

Ang

le L

egs

for F

loor

Mou

ntin

g (

)

or W

all B

rack

ets

(

).

AN

D

Furn

ish

and

inst

all a

s sh

own

on p

lans

for M

anua

l Coo

ling

of D

rain

Wat

er T

empe

ratu

re S

epar

ator

Afte

rcoo

ler M

odel

A

5D- _

____

__ ‘

w/ _

____

__ ‘

C.W

. I. (

cold

wat

er in

let)

OR

Fu

rnis

h an

d in

stal

l as

show

n on

pla

ns fo

r Aut

omat

ic C

ont ro

l of D

rain

Wat

er T

empe

ratu

re S

epar

ator

Afte

rcoo

ler

Mod

el 1

8DF

____

___

“, 16

DS

___

____

“, o

r 20

AO

___

____

“ w

/ ___

____

“ C

.W.I.

, a T

empe

ratu

re R

egul

ator

Val

ve,

Stra

iner

, and

a 2

” Dia

l Bim

etal

The

rmom

eter

.

A16

DS

– Si

mpl

ified

Aut

omat

ic A

fterc

oole

r. S

imila

r to

our 1

8DF

afte

rcoo

ler d

escr

ibed

abo

ve o

nly

with

out t

he m

iddl

e fla

nges

. Th

is a

fterc

oole

r ac

com

mod

ates

the

cold

wat

er li

ne, s

ensi

ng b

ulb,

and

ther

mom

eter

. S

izin

g sh

ould

mat

ch th

e dr

ain

line

size

. C

oolin

g w

ater

sel

ectio

n fro

m C

hart

“B: a

ssur

e s a

dequ

ate

cool

ing

of c

onde

nsat

e to

dra

in.

Self

Act

uatin

g Te

mpe

ratu

re R

egul

ator

Val

ve

Aut

omat

ical

ly c

ontro

ls th

e flo

w o

f coo

ling

wat

er to

the

afte

rcoo

ler f

ittin

gs b

y re

spon

ding

to th

e te

mpe

ratu

re c

hang

e at

the

bulb

. E

ach

is fa

ctor

y se

t at 1

35 d

eg. F

. with

an

adju

stab

le ra

nge

from

115

-18

0 de

g. F

. the

6’ c

apill

ary

allo

ws

inst

alla

tion

of th

e va

lve

in th

e co

ld w

ater

line

whi

le th

e bu

lb is

re

mot

ely

loca

ted

in th

e af

terc

oole

r. T

he v

alv e

siz

e sh

ould

cor

resp

ond

to th

e re

com

men

ded

size

on

Cha

rt “B

“Y”

Typ

e St

rain

er

Cas

t iro

n co

nstru

ctio

n w

ith a

.033

inch

sta

inle

ss s

teel

scr

een

are

reco

mm

ende

d pr

ior t

o te

mpe

ratu

re

regu

lato

r val

ve o

r sol

enoi

d va

lve

in th

e co

ld w

ater

line

to p

rote

ct th

ese

cold

wat

er v

alve

s.

Bi-M

etal

The

rmom

eter

S

tain

less

ste

el b

ody

in 4

” or 6

” sta

inle

ss s

teel

ste

m. ¼

” con

nect

ion

prov

ided

for u

se in

the

A18

DF,

A

16D

S o

r A20

AO

afte

rcoo

lers

. G

radu

ated

sca

le s

how

s te

mpe

ratu

r e ra

nge

50 to

300

deg

. F.

Page 2: Intermittent Blowdown - Deaeratordeaerator.com/wp-content/uploads/2015/12/IB-Brochure.pdfModel Number Selection Series Tank In let Drain Vent INTERMITTENT BLOWDOWN EXAMPLE: I B 1 4

IB

=Int

erm

itten

t B

low

dow

n 1

420

= Ta

nk S

ize

(14

” x 2

0” lo

ng)

1=1

” B

low

dow

n

Inl

et

2=2

” D

rain

2

=2”

Vent

INTE

RMITT

ENT B

LOW

DOW

N W/A

FTER

COOL

ER

M

ODEL

SERI

ES

TAN

K

INLE

T

DRAI

N

VENT

SE

LECT

ION C

HART

*CU

STO

M S

IZE

S A

VA

ILA

BLE

BLO

WD

OW

N M

OD

EL

Boi

ler

Pres

sure

(PSI

G)

Blo

w-

dow

n (#

/HR

)

Con

dens

ate

(GPM

) C

old

Wat

er

(GPM

)

Tank

D

ia.

“A”(

in)

Tank

Le

ngth

“B

”(in

)

“C”

“D”

Inle

t “E

” D

rain

“F

” Ve

nt

“G”

Col

d H

2 0 “H

IB14

20-1

-2-2

50

6,

444

12.1

7 12

.52

14”

42”

2”

11”

1”

2”

2”

.5”

IB14

20-1

.25-

3-3

50

13,4

72

25.4

4 26

.17

14”

44”

4”

11”

1.25

” 3”

3”

.5

IB14

34-1

.5-3

-3

50

19,4

37

36.7

0 37

.76

14”

58”

4”

11”

1.25

” 3”

3”

.7

5”

IB14

34-2

-4-4

50

37

,454

70

.69

72.7

4 14

” 71

” 11

” 13

” 2”

4”

4”

1.

25”

IB14

20-1

-3-3

10

0 11

,844

21

.18

21.8

0 14

” 44

” 4”

11

” 1”

3”

3”

.5

IB14

34-1

.25-

3-4

100

22,2

84

39.6

7 40

.82

14”

60”

4”

13”

1.25

” 3”

4”

.7

5”

IB14

34-1

.5-4

-4

100

33,5

73

60.0

3 61

.77

14”

71”

11”

13”

1.5”

4”

4”

1”

IB14

34-2

-4-6

10

0 60

,536

10

8.24

11

1.38

14

” 71

” 11

” 13

” 2”

4”

6”

2”

IB14

34-1

-3-4

15

0 15

,394

26

.48

27.2

5 14

” 60

” 4”

13

” 1”

3”

4”

.5

IB14

34-1

.25-

4-4

150

30,7

92

52.9

6 54

.50

14”

71”

11”

13”

1.25

” 4”

4”

1”

IB14

34-1

.5-4

-6

150

44,6

25

76.8

8 79

.11

14”

71”

11”

13”

1.5”

4”

6”

1.

25”

IB14

56-2

-6-6

15

0 79

,721

13

7.12

14

1.09

14

” 96

” 13

” 13

” 2”

6”

6”

2”

IB14

34-1

-3-4

20

0 19

,690

32

.84

33.8

0 14

” 60

” 4”

13

” 1”

3”

4”

.7

5”

IB14

34-1

.25-

4-6

200

37,8

48

63.1

3 64

.96

14”

71”

11”

13”

1.25

” 4”

6”

1.

25”

IB14

56-1

.5-4

-6

200

53,8

93

89.8

9 92

.50

14”

93”

11”

13”

1.25

” 4”

6”

1.

5”

IB14

56-2

-6-6

20

0 94

,496

15

7.62

16

2.19

14

” 96

” 13

” 13

” 2”

6”

6”

2”

IB14

34-1

-4-4

25

0 21

,838

35

.25

36.2

7 14

” 71

” 11

” 13

” 1”

4”

4”

1”

IB14

56-1

.25-

4-6

250

42,3

39

68.3

4 70

.32

14”

93”

11”

13”

1.25

” 4”

6”

1.

5”

IB14

56-1

.5-4

-6

250

60,9

62

98.3

9 10

1.25

14

” 93

” 11

” 13

” 1.

50”

4”

6”

2”

IB14

56-2

-6-8

25

0 10

9,26

117

6.35

18

1.46

14

” 96

” 13

” 13

” 2”

6”

8”

2.

5”

IB14

56-1

-4-6

30

0 25

,060

39

.70

40.8

5 14

” 93

” 11

” 13

” 1”

4”

6”

1”

IB14

56-1

.25-

4-6

300

48,7

54

77.2

3 79

.47

14”

93”

11”

13”

1.25

” 4”

6”

1.

5”

IB14

56-1

.5-6

-6

300

69,7

96

110.

56

113.

76

14”

96”

13”

13”

1.50

” 6”

6”

2”

IB14

56-2

-6-8

30

0 12

2,55

019

4.12

19

9.75

14

” 96

” 13

” 13

” 2”

6”

8”

2.

5”

INTE

RMITT

ENT B

LOW

DOW

N W/A

FTER

COOL

ER

C

HART

CH

ART

Mode

l Num

ber S

elec

tion

Ser

ies

Tan

k

In

let

D

rain

V

ent

I

NTE

RM

ITTE

NT

BLO

WD

OW

N

EXAM

PLE:

I B

1 4

2 0

--

1

--

2

--

2

_

_

_

_ _

_

_

_

_

Typi

cal A

rrang

emen

t


Top Related