340-360 1500V Series
JAM72S01 340-360/PR 1500V Percium Series
355
47.45
38.76
9.69
9.16
18.28
ELECTRICAL PARAMETERS AT NOCT
Max Power (Pmax) [W]
Open Circuit Voltage (Voc) [V]
Max Power Voltage (Vmp) [V]
Short Circuit Current (Isc) [A]
Max Power Current (Imp) [A]
TYPE
Electrical data in this catalog do not refer to a single module and they are not part of the offer. They only serve for comparison among different module types.US_EN_20170728A
NOCT
Harvest the SunshinePremium Cells, Premium Modules
www.jasolar.com
P r
Current-Voltage Curve (JAM72S01-355/PR)
Power-Voltage Curve (JAM72S01-355/PR)
Current-Voltage Curve (JAM72S01-355/PR)
40℃
55℃
70℃
10℃
25℃
SPECIFICATIONS
Cell
Weight
Dimensions
Cable Cross Section Size
Junction Box
Connector
Packaging Configuration
1960×991×40mm
72 (6×12)
IP67, 3 diodes
Amphenol UTX
27 Per Pallet
1500V
ELECTRICAL PARAMETERS AT STC
TYPE
Module Efficiency [%]
Power Tolerance
STC Irradiance 1000W/m²,cell temperature 25℃, AM 1.5G
345
47.05
38.39
9.54
8.99
17.76
340
46.86
38.18
9.46
8.91
17.50
350
47.24
38.58
9.61
9.07
18.02
JAM72S01 -340/PR
-0~+5W
+0.060%/℃
-0.300%/℃
-0.390%/℃
customized cable length available upon request
-40℃~+85℃
20A
5400Pa2400Pa
45±2℃
Type 1
Class A
1500V DC (UL)Maximum System Voltage
Operating Temperature
Maximum Series Fuse
Maximum Static Load, Front* Maximum Static Load, Back*
NOCT
Fire Performance
Application Class
360
47.66
38.96
9.78
9.24
18.53
360W Mono Si 72 Cells
Junction Box
Label
Draining Holes8 places
Mounting holes8 places
Grounding holes6 places
Mounting holes4 places for NEXTracker
4 places for NEXTracker
Mono 156.75x156.75mm
*For NexTracker installations static loading performances: front load measures 2400Pa while back load measures 1600Pa.
MECHANICAL DIAGRAMS
OPERATING CONDITIONS
CHARACTERISTICS
No. of cells
4mm2
22.5kg±3%
Rated Maximum Power (Pmax) [W]
Open Circuit Voltage (Voc) [V]
Maximum Power Voltage (Vmp) [V]
Short Circuit Current (Isc) [A]
Maximum Power Current (Imp) [A]
(α_Isc)
(β_Voc)
(γ_Pmp)
Irradiance 800 W/m2 , ambient temperature 20℃,wind speed 1 m/s, AM 1.5G
261
43.88
35.81
7.68
7.29
250
43.28
35.25
7.48
7.09
257
43.68
35.78
7.61
7.19
254
43.52
35.51
7.54
7.14
265
44.10
36.03
7.74
7.34
(12AWG)(112 lb/ft )2
(50 lb/ft )2C
urre
nt (A
)
0
2
4
6
8
10
0 10 20 30 40 50
1000W/m2
800W/m2
600W/m2
2400W/m
200W/m2
Pow
er (W
)
0
50
100
150
200
250
300
400
0 10 20 30 40 50
1000W/m2
800W/m2
600W/m2
400W/m2
200W/m2
Cur
rent
(A)
0
2
4
6
8
10
0 10 20 30 40 50
Voltage (V)
Voltage (V)
350
Voltage (V)
JAM72S01 -345/PR
JAM72S01 -350/PR
JAM72S01 -355/PR
JAM72S01 -360/PR
JAM72S01 -340/PR
JAM72S01 -345/PR
JAM72S01 -350/PR
JAM72S01 -355/PR
JAM72S01 -360/PR
Excellent Low-lightPerformance
EQE—External quantum efficiency
Cur
rent
[A]
300 400 500 600 700 800 900 1000 1100
Wavelength (nm)
1.0
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0.0
PERCIUMNormal Mono
Nor
mal
ized
EQ
E
Average Mass Production Efficiency >21%Percium Cell
Cost saving estimation made by comparison between 330W and 355W modules
Benefit: Save System Costs Per Watt
More Power Per m²
Higher conversion efficiency - more power production
per unit area
Lower System Cost
Transportation costs
Installation costs
BOS costs
Higher conversion efficiency helps you to save
Benefit: 7% More Power
Percium module 355Wp VS Conventional module 330Wp
Conventional Percium
+7%
Harvest the SunshinePremium Cells, Premium Modules
Harvest the SunshinePremium Cells, Premium Modules
6% less
Installation costs
7% less
Transportation costs
4% less
BOS costs
High Reliability
Comprehensive Certificates
IEC 61215, IEC 61730, UL1703, CEC Listed, MCS and CE
ISO 9001: 2008: Quality management systems
ISO 14001: 2004: Environmental management systems
BS OHSAS 18001: 2007: Occupational health and safety management systems
Environmental policy: The first solar company in China to complete Intertek's carbon
footprint evaluation program and receive the green leaf mark verification for our products
PID-resistance tests
Certified by TÜV SÜD and ETL
Industry-leading cell technology
High quality components from best suppliers
Harsh climate environment endurance tests
Long-term reliability tests
Manufacturing inspected and certified by PI-Berlin and Solar-IF
100% in-house automatic manufacturing
Other Features
FraunhoferPIBERLIN
PI
Thresher Test
TC 600DH 3000
UV 45 kW/m2HF 30
Hot Spot 20h
Product Warranty12-year product warranty25-year linear power warranty
JA Solar Holdings Co., Ltd.
Partner Section
Additional Insurance Options
PowerGuard�
SPECIALTY INSURANCE SERVICES
SOLARSOLARI N S U R A N C E & F I N A N C E
Excellent mechanical load resistance: Certified to withstand
high wind loads (2400Pa) and heavy snow loads (5400Pa)
Positive power tolerance: 0~+5W
Modules binned by current to improve system performance
5400Pa
2400Pa
0~+5W
finger“inverted” pyramids
np-silicon
passivated layer
AR Coating
SiNx Local BSF
The mono cell technology with passivated backside
and local BSF
>21% average mass production efficiency
Relative module efficency comparison under different irradiance
Source:
Benefit:Excellent Low-light Performance
Enhanced spectral response at longer wavelength boosts low-light performance, which can produce more than 3% additional power compared with conventional module at system side.
93%
94%
95%
96%
97%
98%
99%
100%
101%
102%
100 200 300 400 500 600 700 800 900 1000 1100
Rel
ativ
e ef
ficie
ncy
(%)
Irradiance (W/M2)
Conventional Mono Conventional Poly PERCIUM Mono
Add: Building No.8, Nuode Center, Automobile
Museum East Road, Fengtai District, Beijing, China
Tel: +86 (10) 63611888 Fax:
+86 (10) 63611999
Email: [email protected] [email protected]
JA Solar Holdings Co.,Ltd is a world leading manufacturer of high-performance solar power products that convert sunlight into electricity for residential, commercial and utility-scale power generation. The company was founded in May 2005 and publicly listed on NASDAQ in February 2007. JA Solar has been the world's leading cell producer since 2010, and has firmly established itself as a tier 1 module supplier since 2012. Capitalizing on our strength in solar cell technology, we are committed to provide modules with unparalleled conversion efficiency, yield efficiency, and reliability to enable you to maximize your returns on PV projects. With its leading industry experience, continuous effort on R&D, customer-oriented service and solid financial status, JA Solar is your best choice of long-term trustworthy partner.