Job Performance Requirement 17-2
Conventional Forcible Entry—Door Swinging Toward
the Forcible Entry Team
![Page 2: Job Performance Requirement 17-2](https://reader036.vdocument.in/reader036/viewer/2022062516/56812acd550346895d8ea6cd/html5/thumbnails/2.jpg)
JPR 17-2A
A Check the door to determine swing; the number, type, and location of locking devices; and the
type of door frame and hinges.
![Page 3: Job Performance Requirement 17-2](https://reader036.vdocument.in/reader036/viewer/2022062516/56812acd550346895d8ea6cd/html5/thumbnails/3.jpg)
JPR 17-2B
B Create a gap between the door and jamb by driving the adz or fork end of the Halligan tool
between the door and frame 6 inches above or below the lock.
![Page 4: Job Performance Requirement 17-2](https://reader036.vdocument.in/reader036/viewer/2022062516/56812acd550346895d8ea6cd/html5/thumbnails/4.jpg)
JPR 17-2C
C On tight doors, the gap maybe started with the fork end.
![Page 5: Job Performance Requirement 17-2](https://reader036.vdocument.in/reader036/viewer/2022062516/56812acd550346895d8ea6cd/html5/thumbnails/5.jpg)
JPR 17-2D
D If door is tight, work tool up and down to open up gap.
![Page 6: Job Performance Requirement 17-2](https://reader036.vdocument.in/reader036/viewer/2022062516/56812acd550346895d8ea6cd/html5/thumbnails/6.jpg)
JPR 17-2E
E Set the tool by driving the adz or forkend past the door around the doorstop.
![Page 7: Job Performance Requirement 17-2](https://reader036.vdocument.in/reader036/viewer/2022062516/56812acd550346895d8ea6cd/html5/thumbnails/7.jpg)
JPR 17-2F
F This inside view showshow the adz is set.
![Page 8: Job Performance Requirement 17-2](https://reader036.vdocument.in/reader036/viewer/2022062516/56812acd550346895d8ea6cd/html5/thumbnails/8.jpg)
JPR 17-2G
G Force the door by pulling thetool away from the door.