Download - JOE FALLONDESIGN P;01-5143688 A3
SUBJECT SITE Of APPLICATIONNO. 31 KNOCKSINNA PARK
(rear garden) No. 67 No. 65
EXISTING CONTIGUOUS FRONT ELEVATION [northeast]scale 1:100@A3
No. 31 knocks Inna park(rear garden)
ALL NEW WORKS SHOWN HATCHED
KJ/-. L~l susjeci sheI'JQJ. O/ Of APWICAIION
New aluminium chimney capping to----------------------------------------------------------- (■existing chimney
............-............. -Existing-brick tatap-af x^iimneyJo be^ ---------^---------------------------------------rendered over, to match existing
Extend existing gable roof over new section to form-----------------------------------------------------------new hipped roof, maintaining ridge height; use existing
tiles from rear slope on front to tie in with existing
I no. FTP-V Z-wave electrically controlled centre-pivot-----------------------------------------------------------rooftight size 05, by Fakro or approved simitar
Side of existing roof to be retained in place-All new fascia, soffit, rainwater goods in black.-
to client spec
All new and existing windows to be min- 1,0W/maK u-value. to client spec; At least I
opening section to all habitable room windows on first floor and above to be min.
clear width and height of 450mm, sill ----------------------------------80G-I HDOmm above FFl -
Existing plaster finish to be retained and repainted- Existing brick outer leaf to be replaced with new redbrick with white mortar, to match new construction
Existing fence panels to boundary- Sloped planting bed to be formed-
Ground to be sloped to allow for level access to- side passage
------------------- -New lower ground tevelto front drive-
No. 65
0
-Nev' red brick with white mopar, to arc litect spec
-Opi ique window to shower -Nev pivot front door recessed within new brick entrance
-Line of existing ground level
ELL iSL
Lwr.FFL -.60.
I
PROPOSED CONTIGUOUS FRONT ELEVATION [northeast]scale 1:100@A3
Client
Francis Mulcahy & Rachel Bowe 67 Granville Park,Blackrock,Co. Dublin,A94 TD28
Revisions
A:STATUS OF DRAWING
Chartered Institute of Architectural Technologists
PLANNING DRAWING ONLY
notes
JOE FALLONDESIGNARCHITECTURE
6. Main Street. Dundrum, Dublin 14.
1A Ryland Street. Bunclody, Enniscorthy, Co. Wexford
P; 01-5143688
P: 053-9377633 A3project Extension and alterations @ 67 Granville Park
dwg no. 21005-PP-06drawing front elevationjob no. 21005 scale as shown date 01.07.21 drawn by ES checked LKUNDER THE BUILDING CONTROL ACT 2007, JOE FALLON IS A REGISTERED ASSIGNED CERTIFIER. REG NO. B0244 SCSI
All work to be carried out in accordance with the current Building Regulations and Technical Guidance Documents. These documents take precedence over any dimensions / notes / specifications on these drawings. The contractor / client is to make a thorough inspection of the site and make themselves fully aware of any peculiarities pertaining there to. The contractor is entirely responsible for the proper setting out of works on site. Written dimensions are to be used in preference to scaling.Contractor / client is to check all dimensions prior to planning stage / construction. Any discrepancies to be reported before work is in hand.Contractor is
deemed to have included for everything required to finish off project to a satisfactory condition though not specifically described on drawings. All work to be supervised and signed off by suitably qualified persons with up to-date insurance and proper Health and Safety. All drainage works to comply with Local Authority Regulations - if in doubt contact Authority.AII works must be carried out using proper materials that are fit for the use for which they are intended and for the conditions in which they are to be used; if in doubt, refer to the harmonised technical specifications.