Download - Jonas Berge Advances in Fieldbus Technology
11 Successful Implementation & Improved Operation
Advances in FOUNDATION fieldbus provide improved usabilityJonas Berge
22 Advances in FOUNDATION fieldbus provide improved usability
Released 2007
Introducing Three Revolutionary Products- iPhone (1st generation)
Widescreen iPod with touch controlsRevolutionary mobile phoneBreakthrough Internet communicator
YouTube 4:47
33 Advances in FOUNDATION fieldbus provide improved usability
Quiz: Which was the first phone with web browser?
Apple iPhoneNokia 9000 CommunicatorMotorola Razr
Released 1996
• Not easy to navigate• People not yet
Internet savvy• No habit of
searching web
44 Advances in FOUNDATION fieldbus provide improved usability
Quiz: Which was the first phone with music player?
Apple iPhoneNokia 9000 CommunicatorSony Ericsson W800
Released 2005
• Had to rip CDs and copy files
• Not easy to find/search songs
55 Advances in FOUNDATION fieldbus provide improved usability
Quiz: Which was the first phone where you can install applications?
Apple iPhoneHandspring (Palm) Treo 180Sony Ericsson W800
Released 2002
• Apps not easy to buy• Not easy to use• “too small”
66 Advances in FOUNDATION fieldbus provide improved usability
iPhone Ease-of-Use- Human Centered Design
iTunes storeWider screenMulti-touch gesturesThreaded text messagingYouTube as application
Power of Context: The time was right; people were ready
for computer, Internet, synching, and dependent on
the web
77 Advances in FOUNDATION fieldbus provide improved usability
“We’re Gonna Reinvent the Phone”
88 Advances in FOUNDATION fieldbus provide improved usability
Past Fieldbus Learning CurveDifferent from 4-20 mA
Had to download DD from the Internet– Computer skills– Internet skills
Had to load DD on the system– System skills
Can’t see signal with multimeter
Too DifficultDownload errorsConfiguration errorsCryptic device error codesHad to change system configuration at device replacementScattered parameters with cryptic namesConservative design process and constraints
This was a problem in before but isn’t today
99 Successful Implementation & Improved Operation
Fieldbus Ease of UseBetter but not so different...
1010 Advances in FOUNDATION fieldbus provide improved usability
Key Feature Enhancements till DateSelection Configuration Commissioning Maintenance Replacement
Error Free Download
Field Diagnostic
Specification
Host Profile Test and Registration
Device Replacement Guideline and Specifications
Device Level Methods and Views
1111 Advances in FOUNDATION fieldbus provide improved usability
Commissioning:- Faster, but...
User Experience– Download offline configuration results in errors– Multiple downloads typically resolve errors, but this
increases overall commissioning time
Analysis– Devices apply checks to maintain consistency during
download– Device expects a specific order for parameter
download– Some parameters should not be written during an
automated download
1212 Advances in FOUNDATION fieldbus provide improved usability
ITK6 Profile Improves CommissioningNew “no_download” lists inform host which parameters should not be part of an automated download– Described in EDD– e.g. calibration parameters– e.g. vendor specific behavioral parameters
New deferral of inter-parameter checks– Disables consistency checks during automated
download– Once completed, device re-evaluates configuration – Reduces errors due to parameter order mismatch
New parameter BLOCK_ERR_DESC_n – Provides more detail to the configuration block error
1313 Advances in FOUNDATION fieldbus provide improved usability
Maintenance- Rationalized with diagnostics, but...
User Experience– Diagnostic data is represented in different forms,
making integration difficult
Analysis– A common structured approach across networks is
necessary to bring the right information to the right person in context
1414 Advances in FOUNDATION fieldbus provide improved usability
ITK6 NAMUR NE107 Improves Self-Monitoring and Diagnosis of Field Devices
Diagnosis results must be reliable
Diagnosis results must always be viewed in the context of the application.
Internal diagnosis must be categorized into 4 standard “status signals”
Configuration must be free, as reactions will depend on the user's requirements
Detailed information can be read out by the device specialist
1515 Advances in FOUNDATION fieldbus provide improved usability
Role-Based Diagnostics
1
Asset ManagementMaintenance Station
Process ControlEngineering Station
HSE Control Network
H1 Process Network
Plant operators
Plant maintenance engineering
1616 Advances in FOUNDATION fieldbus provide improved usability
Device Replacement- Interoperability works, but...
User Experience– Replacing devices requires access to system software
Analysis– Replacement devices are sometimes newer than the
device used before– A new type or version of device requires the DD to be
loaded and the tag to be updated
1717 Advances in FOUNDATION fieldbus provide improved usability
ITK6 Improves Device ReplacementFieldbus Foundation published an application note for suppliers to define rules for ‘Like’ device replacementNew parameter COMPATIBILITY_REV declare compatibility rulesEnables systems to use an updated device that was commissioned with a prior version device versionSimplify the 2 a.m. device replacement scenario
1818 Advances in FOUNDATION fieldbus provide improved usability
Device Setup and Diagnostics- Device management improved, but...
User Experience– Users must browse through many blocks to get an
overview of health from all diagnostics– Users must go to many blocks to completely configure
the device
Analysis– Traditional DD accessed the blocks one by one
1919 Advances in FOUNDATION fieldbus provide improved usability
ITK6/HPR Graphically Enhanced EDDLIntegrating Data from Multiple Blocks
Easier overviewDrill down for details
2020 Advances in FOUNDATION fieldbus provide improved usability
EDDL Wizards Across Blocks
2121 Advances in FOUNDATION fieldbus provide improved usability
Host Profile Registration2008 2009 2010 2011 2012
1H 2H 1H 2H 1H 2H 1H 2H 1H 2H
Host Interoperability
Support Test(HIST)
Host 6Xb Profile Test/Registration
Host 6Xa Profile Test/Registration
Valid through June 2010
2222 Advances in FOUNDATION fieldbus provide improved usability
“Project Gemstone”Next wave of usability improvements– Device templates– Device replacement– Etc.
ITK7HPR compliance level ‘C’
2323 Successful Implementation & Improved Operation
Summary
2424 Advances in FOUNDATION fieldbus provide improved usability
SummaryNew features improve configuration, commissioning, maintenance and replacementReduce complexity while increasing interoperability and productivityHPR assures features are consistent across systems
2525 Advances in FOUNDATION fieldbus provide improved usability
Existing Fieldbus UsersUpgrade your fieldbus system to latest version to take advantage of these features
2626 Advances in FOUNDATION fieldbus provide improved usability
We’re Reinventing Fieldbus
Smart
ITK4ITK5
HIST
ITK6
HPR61b
smart
Not so smart
easytouse
hardto
use
Gemstone