Download - Jual Murah Harga Total Station Sokkia Cx - 101, Cx - 102 , Cx- 103 , cx - 105 Call: 0818.4343.40 %%
• RED-tech Technology Reflectorless EDM• Long-range Bluetooth® Technology• Advanced Angle Measurement System• The Longest Battery Life – 36 Hours!• Waterproof, Rugged, and Operator Friendly• Advanced Security and Maintenance with TSshieldTM
CX SeriesCompaCt X-ellenCe Station
Tradition Meets Innovation
Long-Range Bluetooth® Technology*
• TheCXseriesoftotalstationsfeaturesBluetooth®Class1wirelesstechnologyforreliabledatacommunications.• AllCXdataisinstantlyavailableattheBluetooth®-equippedcontroller. *Offeredasanoptioninsomeareas.
Advanced Angle Measurement System • CXfeaturesSokkia’soriginal absoluteencodersthatprovide long-termreliabilityinany jobsitecondition.Dual-axis compensatorensuresstable measurementsevenwhen setuponuneventerrain.• Sokkia’straditionalmotion clampandtangentscreware employedtoensurestable anglemeasurement.•CX-101andCX-102featuregroundbreakingIACS(Independent AngleCalibrationSystem)technologyforextremelyreliable anglemeasurement.
The Longest Battery Life - 36 Hours!• TheCXsinglebatterycan lastupto36hours.*• Greatlyreduceslikelihoodof lowpowerduringany full-dayswork.•Eliminatestheneedfor nightlyrechargingorcarrying extrabatteries. *Operatingtimewillvarydependingupon environmentalconditionsandCXactivity.
RED-tech Technology Reflectorless EDM
• Fastestmeasurmenttimeinitsclass.• Sokkiatraditionalpinpointprecisioninreflectorlessdistance measurement.•Reflectorlessoperationfrom30cmto500m.•CoaxialEDMbeamandlaser-pointerprovidefastandaccurateaiming.•Ensuresaccuracyevenwithreflectivesheets.
Inspired by Tradition, Ready for The Future.
Theultra-narrowEDMbeamcanpreciselymeasurewalls,corners,manholesontheroadsurface,evenchain-linkfencesandtreebranches.
Waterproof, Rugged, and Operator Friendly • IP66dustproof/waterproofrating.• Metalchassisandheavydutyhandle addruggedness.• Standardusagetemperature range-20to+50°C.Low temperaturemodelscanbeusedas lowas-30°C*andhightemperature modelsupto+60°C.* *LowandHightemperaturemodelsavailableasoptions.
• USBTypeAportforconvenientadded memory.UseofincludedUSB accessoryassuresIP66protection.
• One-touchSTARkeyoffersinstant accesstofunctions.
• Convenientlylocated“trigger”keylets youtakeaseriesofmeasurements withthepushofabuttonwithout takingyoureyeoffthetelescope.
• Controlpanelfeatures10-keypad withlargeLCDthatprovidesoptimum viewingandconvenience.* *Controlpanellocationmayvarydependingonregion ormodel.
• Green/Redtelescopeguidelightenhancesworkefficiencyin arangeupto150m.
• Built-inlaserplummetwithfivebrightnesslevelsisequippedfor quickinstrumentsettinginalllightingconditions.(optional)
TSshield™ EveryCXtotalstationisequippedwithatelematics-basedmultifunctioncommunicationsmoduleprovidingtheultimatesecurityandmaintenancecapabilitiesforyourinvestment.Ifanactivatedinstrumentislostorstolen,youcansendacodedsignaltotheinstrumentanddisableit–Yourtotalstationissecureanywhereintheworld!And,inthesamemodule,youhavedailyconnectivitytocloud-basedSokkiaserversthatcaninformyouofavailablesoftwareupdatesandfirmwareenhancements. * FormoredetailofTSshield,pleaserefertotheTSshield’sleaflet.
High-temp ModelsStandard Models
Low-temp Models-30°C (-22°F)
-20°C (-4°F)
0°C (+32°F)
+50°C (+122°F)
+60°C (+140°F)
Operating temperature range
Sokkia Corporation16900 W. 118th Terrace Olathe, KS 66061Phone (800) 4-SOKKIA Fax: (913) 492-0188
www.sokkia.com
Specifications subject to change without notice©2013 Topcon Corporation All rights reserved.
Your local Authorized Dealer is:
CX SeriesSPECIFICATIONS
-Bluetooth®wordmarkandlogosareregisteredtrademarksownedbyBluetoothSIG,Inc.andanyuseofsuchmarksbyTopconisunderlicense.Othertrademarksandtradenamesarethoseoftheirrespectiveowners.-Designsandspecificationsaresubjecttochangewithoutnotice.-Productcolorsinthisbrochuremayvaryslightlyfromthoseoftheactualproductsowingtolimitationsoftheprintingprocess.
Compact X-ellence Station
Standard Accessories•CXmainunit •Lensbrush•Battery(BDC70) •Adjustingpinx2•Batterycharger(CDC68) •Cleaningcloth•Powercable •Operationmanual•Lenscap •USBmemorystick•Lenshood •Lasercautionsign-board•Toolpouch •Carryingcase•Screwdriver •Carryingstrap
CX-101/CX-102/CX-103/CX-105/CX-107
Model CX-101 CX-102 CX-103 CX-105 CX-107
Telescope
Magnification/Resolvingpower 30x/2.5" 30x/3.5"
Others Length:171mm(6.7in.),Objectiveaperture:45mm(1.8in.)(48mm(1.9in.)forEDM),Image:Erect,Fieldofview:1°30'(26m/1,000m),Minimumfocus:1.3m(4.3ft.),Reticleillumination:5brightnesslevels
Angle MeasurementDisplayResolution 0.5"/1"
(0.0001/0.0002gon,0.002/0.005mil)
1"/5"(0.0002/0.001gon,0.005/0.02mil)
Accuracy(ISO17123-3:2001) 1" 2" 3" 5" 7"
IACS(IndependentAngleCalibrationSystem) Provided -
Dual-axiscompensator/Collimationcompensation Dual-axisliquidtiltsensor,workingrange:±6'(±111mgon)/Collimationcompensationavailable
Distance Measurement
Laseroutput*1 Reflectorlessmode:Class3R/Prism/sheetmode:Class1
Measuringrange(underaverageconditions*2)
Reflectorless*3 0.3to500m(1.0to1,640ft.)
Reflectivesheet*4/*5 RS90N-K:1.3to500m(4.3to1,640ft.),RS50N-K:1.3to300m(4.3to980ft.),RS10N-K:1.3to100m(4.3to320ft.)
Miniprisms CP01:1.3to2,500m(8,200ft.),OR1PA:1.3to500m(1,640ft.)
OneAPprism 1.3to4,000m(4.3to13,120ft.)/Undergoodconditions*6:5,000m(16,400ft.)
ThreeAPprisms to5,000m(16,400ft.)/Undergoodconditions*6:to6,000m(19,680ft.)
DisplayResolution Fine/Rapid:0.001m/0.01ft./1/8in.Tracking:0.01m/0.1ft./1/2in.
Accuracy*2(ISO17123-4:2001)(D=measuringdistanceinmm)
Reflectorless*3 (3+2ppmxD)mm*7
Reflectivesheet*4 (3+2ppmxD)mm
AP/CPprism (2+2ppmxD)mm
Measuringtime*8 Fine:0.9s(initial1.7s),Rapid:0.7s(initial1.4s),Tracking:0.3s(initial1.4s)
Interface and Data management
Display/Keyboard GraphicLCD,192x80dots,backlight,contrastadjustment/Alphanumerickeyboard/25keyswithbacklight
Controlpanellocation*9 Onbothfaces Ononeface
Triggerkey Onrightinstrumentsupport
Datastorage Internalmemory Approx.10,000points
Plug-inmemorydevice USBflashmemory(max.8GB)
Interface SerialRS-232C,USB2.0(TypeA,forUSBflashmemory)
Bluetooth®modem(option)*10 Bluetooth®Class1,Ver.2.1+EDR,Operatingrange:upto300m(980ft.)*11
General
Laser-pointer*12 CoaxialredlaserusingEDMbeam
Guidelight*12 GreenLED(524nm)andRedLED(626nm),Operatingrange:1.3to150m(4.3to490ft.)*2
Levels Graphic 6’(InnerCircle)
Circularlevel 10’/2mm
Opticalplummet Magnification:3x,Minimumfocus:0.3m(11.8in.)fromtribrachbottom
Laserplummet(option) Redlaserdiode(635nm±10nm),Beamaccuracy:≤[email protected],Class2laserproduct
Dustandwaterprotection IP66(IEC60529:2001)
Operatingtemperature*13 -4to+122ºF(-20to+50ºC)
Sizewithhandle*9 Controlpanelonbothfaces:W7.5xD7.1xH13.7in.(W191xD181xH348mm)Controlpanelononeface:W7.5xD6.9xH13.7in.(W191xD174xH348mm)
Weightwithbattery&tribrach Approx.12.3lb.(5.6kg)
Power supply
Battery(BDC70) Detachablebattery Li-ionrechargeablebattery
Operatingtime(20ºC) BDC70 Approx.36hours(singledistancemeasurementevery30seconds)
Externalbattery*14(Optional) BDC60:approx.44hours,BDC61:approx.89hours(singledistancemeasurementevery30seconds)
*1IEC60825-1:Ed.2.0:2007/FDACDRH21CFRPart1040.10and11*2Averageconditions:Slighthaze,visibilityabout20km(12miles),sunnyperiods,weakscintillation.*3WithKodakGrayCardWhiteSide(90%reflective).Whenbrightnessonmeasuredsurfaceis30,000lx.orless.Reflectorlessrange/accuracymayvaryaccordingtomeasuringobjects,observationsituationsandenvironmentalconditions.*4Whenthemeasuringbeam’sincidenceangleiswithin30ºinrelationtothereflectivesheettarget.*5Measuringrangeintemperaturesof-30to-20°C(-22to-4°F)withLowTemperaturemodelsand50to60°C(122to140°F)withHighTemperaturemodels:RS90N-K:1.3to300m(4.3to980ft.),RS50N-K:1.3to180m(4.3to590ft.),RS10N-K:1.3to60m(4.3to190ft.)*6Goodconditions:Nohaze,visibilityabout40km(25miles),overcast,noscintillation.*7Measuringrange:0.3to200m*8Typical,undergoodconditions.Reflectorlessmeasurementtimemayvaryaccordingtomeasuringobjects,observationsituationsandenvironmentalconditions.*9Controlpanellocationmayvarydependingonregionormodel.*10UsageapprovalofBluetoothwirelesstechnologyvariesaccordingtocountry.Pleaseconsultyourlocalofficeorrepresentativeinadvance.*11Noobstacles,fewvehiclesorsourcesofradioemissions/interferenceinthenearvicinityoftheinstrument,norain.*12Thelaser-pointerandtheguidelightdonotworksimultaneously.*13LowTemperaturemodels:-30to50°C(-22to122°F)andHighTemperaturemodels:-20to60°C(-4to140°F,Nodirectsunlight)areavailableonbuilt-to-orderbasis.*14ForCX-101,CX-102andLowtemperaturemodels.
SOK-1008RevB3/13