Download - KLASIK - R
Replace your old radiators with new ones!
Steel panel radiators for renovation jobs, suitable for replacement of cast-iron or steel sectional radiators.
KLASIK - R
CE mark used from the year 2005
03/2011
10YEAR
GUARANTEE Fitt
ing
da
ta
The company reserves the right to make technical changes.01/11.670.1 EN
KLASIK - RFitting data
Z-U140 bracket
Z-U290 bracket
Fitting data
Basic technical data
The Z-U140 bracket can be used for fixing the radiator at a fixed distance of the radiator from the wall of 48 mm, or the Z-U290 bracket with variable distance of up to 100 mm from the wall.
27
68
X3 X5
399
90
X4(L)
(H)
25
554
85
X1
X2
500
399
71
554
X1
X2
500
50
0 22
85
27
55
4
X2
centre line of the lower connection pipe
centre line of the upper connection pipe
X1
48120
68
X3 X5
399
90
X4(L)
(H)
25
554
85
X1
X2
500
399
71
554
X1
X2
500
50
0 8
39
97
1
27
27
55
4
X2
centre line of the lower connection pipe
centre line of the upper connection pipe
X1
100115
type 20 R 21 R 22 R 33 R
X1 81 81 98 98
X2 114 114 148 203
type 20 R 21 R 22 R 33 R
HeightH [mm] 554 554 554 554
Radiator weight [kg/m]
22,6 28,0 34,6 52,4
Water volume[l/m]
5,5 5,5 5,5 8,2
Flow coefficient
at [m2]
1,0 x 10 -4
(DN 15)1,0 x 10 -4
(DN 15)1,0 x 10 -4
(DN 15)1,18 x 10 -4
(DN 15)
Resistance coefficient
ξt [-]8,5 (DN 15) 8,5 (DN 15) 8,5 (DN 15) 5,8 (DN 15)
Standard heat output[W/m]
914 1210 1576 2257
temperature exponent
n [-]1,3010 1,3300 1,3344 1,3364
type 20 R 21 R 22 R 33 R
X1 133 133 150 150
X2 166 166 200 255
X2
X1
500
2773
600
Y
68
25
X3X4 X5
(L)
445
25
90
(H)
39
9
68
X3X5X4
(L)
Length L [mm]
400 500 ÷ 1600 1800 2000 2300 2600 3000
X3 133 133 133 133 133 133 133
X4 - - 900 1000 1133 1300 1500
X5 133 133 133 133 133 133 133
Manufactured by:
KORADO, a. s.Bří Hubálků 869, 560 02 Česká TřebováCzech RepublicE-Mail: [email protected]://www.korado.comPR
OCE
dU
RE F
OR
REPL
aCE
MEn
t O
F Ra
dia
tORS
KLASIK - R
Source of information: Czechoslovak catalogue for construction 14/5 Radiators, basic advice for 1991
Heat output of sectional radiators
The company reserves the right to make technical changes.
Sectional radiators
[mm
] Steel panel radiator
cast-iron steel RadiK KLaSiK - R
575 ÷ 610 575 ÷ 610 H 554
500 500 h 500
110 160 220 200 150 200 B 66 66 100 155
500/110 500/160 500/220 500/200 500/150 500/200 type 20 R 21 R 22 R 33 R
number of sections n [pcs]
number of sections n [pcs]
appropriate length of the radiator L [mm]
5 3 3 3 5 4 400
6 4 3 4 6 5 500 400
7 5 4 4 7 5 600 400 400
8 6 5 5 8 7 700 500 400
10 7 6 7 10 8 800 600 500
11 8 6 7 11 9 900 700 500 400
12 9 7 8 12 10 1000 800 600 400
13 10 8 9 13 11 1100 800 700 500
15 11 9 10 15 12 1200 900 700 500
16 12 10 11 16 14 1400 1000 800 600
17 13 10 12 17 14 1400 1100 800 600
18 14 11 12 18 15 1600 1100 900 600
20 15 12 13 20 16 1600 1200 900 700
22 16 13 15 22 18 1800 1400 1000 700
24 18 14 16 24 19 2000 1400 1100 800
25 19 15 17 25 21 2000 1600 1200 800
26 20 15 17 26 22 2300 1600 1200 900
29 22 17 20 29 24 2300 1800 1400 1000
30 23 18 20 30 25 2600 1800 1400 1000
33 25 20 22 33 27 2600 2000 1600 1100
35 26 21 23 35 28 3000 2300 1600 1100
38 28 23 26 38 31 3000 2300 1800 1200
38 29 23 26 38 31 3000 2300 1800 1400
40 30 23 26 40 32 2600 1800 1400
44 33 26 29 44 36 2600 2000 1400
50 38 30 34 50 41 3000 2300 1600
57 43 34 38 57 46 2600 1800
64 48 38 43 64 51 3000 2000
66 50 39 44 66 54 3000 2300
You can find a replacement for your cast-iron and steel sectional radiators yourself in the RadiK KLaSiK – R steel panel radiator range
1. 1.
3.
5.
3.
5.
7.
9.
2. 2.
4.
4.
6.
8.
material of radiator connecting pitch h [mm] depth B [mm] heat output [W/section]
(90/70/20 °C)
steel 500
150 90160 93200 110220 121
cast-iron 500
110 92150 107160 120200 134220 151250 169
identification of the old radiator:Determine material (cast-iron/steel)*
Measure the height of the radiator H
Check whether the connecting pitch h is 500 mm
Measure the depth of the radiator B
Count the number of sections (“ribs”)
Looking for a replacement in the table:According to identification (see above), look in the left part of the table for the appropriate column, corresponding to the type of the old radiator
Find the row with the appropri-ate number of sections n (if the precise number is not shown in the table, choose the next highest)
Select the most suitable length for the new steel panel radiator L in the row with the appropriate num-ber of sections in the right (blue) part of the table (this depends on the type of steel panel radiator).
After selecting the type of steel pa-nel radiator, once again check its depth B, to see whether it meets your requirements
H [mm] - height of the radiatorh [mm] - connecting pitchL [mm] - length of the radiator B [mm] - depth of the radiator
* if the surface of your sectional radiator is rough, you have a cast-iron radiator
H
h
LB
tECH
niC
aL
da
ta, O
vER
viE
W O
F tY
PES
The company reserves the right to make technical changes.
KLASIK - R FinishThe technology used guarantees the achievement of threebasic goals:
• long-term corrosion resistance and mechanical durability• fine-quality finish• hygienic surface
The surface finish is done in three basic phases:
1) Preparation of the steel surface – includes degreasing,phosphating, and rinsing in three stages.
2) Putting on the first layer of paint using the cataphoreticmethod (KTL). The layer of paint is evenly spread over the whole radiator. The KTL paint gains its final anticorrosion, adhesive, and mechanical and chemical characteristics in a drying oven. This phase of surface finishing is of decisive importance for the long life span of the radiator.
3) Putting on the final layer of paint – epoxy-polyester powder is applied using automatic dusting pistols in an electrostatic field of a dusting compartment. After it is oven dried and cooled, the finish of the radiator is completed.
The surface finishing of the radiators is done with a maximum effort to protect the environment, during production and use.
Radiators are delivered in white powder coat RAL 9016 as standard, on request also in other colours. For more information on the colours available see please the colour card.
Degreasing and phosphating
Cataphoresic paint
Epoxy-polyester powder
Colour card
1.
1.
3.
3.
2.
2.
notice: The colour of the radiator may vary in comparison with the colour shown in the colour card. *Irregular pigment of Colours coded 29 and 30 is their natural feature. The standard paint finish is white RAL 9016,other colours are available at an extra charge.Surcharge: RadiK +30%
Fin
iSH
, CO
LOU
R C
aRd
The company reserves the right to make technical changes.
KLASIK - R
description Overview of types
The RadiK KLaSiK – R model is a steel panel radiator in KLASIK design, modified for swift replacement of cast-iron sectional radiators with a connecting pitch of 500 mm.
The height H = 554 mm guarantees its problem-free fitting in place of the old radiator. It allows for left or right side connection to the heating system distribution mains and is designed for heating systems with forced or gravity circulation. Two upper and lower fixing lugs are welded onto the back, radiators 1800 mm in length or longer have six welded fixing lugs.
The wide range of types of RADIK KLASIK - R allows you to always choose the most suitable and appropriate length.
All radiators are supplied with:• an air vent• a blanking plug• upper grille• side covers
Height H 554 mm
Length L
400, 500, 600, 700, 800, 900, 1000, 1100, 1200,
1400, 1600, 1800, 2000, 2300, 2600, 3000 mm
depth BTyp 20 RTyp 21 RTyp 22 RTyp 33 R
66 mm66 mm
100 mm155 mm
Connecting pitch 500 mm
Connecting thread 4 x G1/2 inside
Highest allowed working pressure
10 bar
test pressure 13 bar
Highest allowed working temperature
110 °C
Basic paint KTL
Surface paint white RAL 9016
guarantee period 10 years
Radiator connection left or right side
side – one sideϕ = 1
side – two sides diagonalϕ = 1recommended for: L ≥ 3 x H
Examples of connection to the heating system
Y
X1
X2
600500
type 20 R
type 21 R
type 22 R
type 33 R
H
L
BB
BB
h
technical data
50
0
50
0
The company reserves the right to make technical changes.
20 °C typ 20 R typ 21 R typ 22 R typ 33 R
Length L [mm]
t1/t2
[°C]
Height H [mm]
554 554 554 554
400
90/70 460 612 798 114375/65 366 484 630 90370/55 293 386 503 72055/45 187 243 316 452
500
90/70 575 765 997 142875/65 457 605 788 112970/55 366 483 628 90055/45 233 304 395 566
600
90/70 690 918 1196 171475/65 548 726 946 135470/55 440 579 754 107955/45 280 365 474 679
700
90/70 805 1071 1396 200075/65 640 847 1103 158070/55 513 676 880 125955/45 327 426 554 792
800
90/70 920 1224 1595 228575/65 731 968 1261 180670/55 586 772 1005 143955/45 373 487 633 905
900
90/70 1035 1377 1795 257175/65 823 1089 1418 203170/55 660 869 1131 161955/45 420 548 712 1018
1000
90/70 1150 1530 1994 285775/65 914 1210 1576 225770/55 733 966 1257 179955/45 467 608 791 1131
1100
90/70 1265 1683 2193 314275/65 1005 1331 1734 248370/55 806 1062 1382 197955/45 513 669 870 1244
1200
90/70 1380 1836 2393 342875/65 1097 1452 1891 270870/55 880 1159 1508 215955/45 560 730 949 1357
1400
90/70 1609 2142 2792 399975/65 1280 1694 2206 316070/55 1026 1352 1759 251955/45 653 852 1107 1584
1600
90/70 1839 2448 3190 457175/65 1462 1936 2522 361170/55 1173 1545 2011 287855/45 747 974 1265 1810
1800
90/70 2069 2754 3589 514275/65 1645 2178 2837 406370/55 1319 1738 2262 323855/45 840 1095 1423 2036
2000
90/70 2299 3059 3988 571375/65 1828 2420 3152 451470/55 1466 1931 2513 359855/45 933 1217 1581 2262
2300
90/70 2644 3518 4586 657075/65 2102 2783 3625 519170/55 1686 2221 2890 413855/45 1073 1400 1819 2602
2600
90/70 2989 3977 5184 742775/65 2376 3146 4098 586870/55 1906 2510 3267 467855/45 1213 1582 2056 2941
3000
90/70 3449 4589 5982 857075/65 2742 3630 4728 677170/55 2199 2897 3770 539755/45 1400 1825 2372 3394
Heat output according to En 442 description of how to order radiators Colour card
Model type Code for ordering
RadiK KLaSiK-R
20 R 20-HHHLLL-R0-10
21 R 21-HHHLLL-R0-10
22 R 22-HHHLLL-R0-10
33 R 33-HHHLLL-R0-10
table for creation of a code
Example for creation of a code
RadiK KLaSiK - R steel panel radiator.type 22, height H = 554 mm , length L = 1800 mm, Colour White RAL 9016
Correct code: 22-HHHLLL-R0-10 22-055180-R0-10
KLASIK - R
22-HHHLLL-R0-10Colour code Additional informationModel numberLength in cmHeight in cmType number
Replace your old radiators with new ones!
Steel panel radiators for renovation jobs, suitable for replacement of cast-iron or steel sectional radiators.
KLASIK - R
CE mark used from the year 2005
03/2011
10YEAR
GUARANTEE Fitt
ing
da
ta
The company reserves the right to make technical changes.01/11.670.1 EN
KLASIK - RFitting data
Z-U140 bracket
Z-U290 bracket
Fitting data
Basic technical data
The Z-U140 bracket can be used for fixing the radiator at a fixed distance of the radiator from the wall of 48 mm, or the Z-U290 bracket with variable distance of up to 100 mm from the wall.
27
68
X3 X5
399
90
X4(L)
(H)
25
554
85
X1
X2
500
399
71
554
X1
X2
500
50
0 22
85
27
55
4
X2
centre line of the lower connection pipe
centre line of the upper connection pipe
X1
48120
68
X3 X5
399
90
X4(L)
(H)
25
554
85
X1
X2
500
399
71
554
X1
X2
500
50
0 8
39
97
1
27
27
55
4
X2
centre line of the lower connection pipe
centre line of the upper connection pipe
X1
100115
type 20 R 21 R 22 R 33 R
X1 81 81 98 98
X2 114 114 148 203
type 20 R 21 R 22 R 33 R
HeightH [mm] 554 554 554 554
Radiator weight [kg/m]
22,6 28,0 34,6 52,4
Water volume[l/m]
5,5 5,5 5,5 8,2
Flow coefficient
at [m2]
1,0 x 10 -4
(DN 15)1,0 x 10 -4
(DN 15)1,0 x 10 -4
(DN 15)1,18 x 10 -4
(DN 15)
Resistance coefficient
ξt [-]8,5 (DN 15) 8,5 (DN 15) 8,5 (DN 15) 5,8 (DN 15)
Standard heat output[W/m]
914 1210 1576 2257
temperature exponent
n [-]1,3010 1,3300 1,3344 1,3364
type 20 R 21 R 22 R 33 R
X1 133 133 150 150
X2 166 166 200 255
X2
X1
500
2773
600
Y
68
25
X3X4 X5
(L)
445
25
90
(H)
39
9
68
X3X5X4
(L)
Length L [mm]
400 500 ÷ 1600 1800 2000 2300 2600 3000
X3 133 133 133 133 133 133 133
X4 - - 900 1000 1133 1300 1500
X5 133 133 133 133 133 133 133
Manufactured by:
KORADO, a. s.Bří Hubálků 869, 560 02 Česká TřebováCzech RepublicE-Mail: [email protected]://www.korado.comPR
OCE
dU
RE F
OR
REPL
aCE
MEn
t O
F Ra
dia
tORS
KLASIK - R
Source of information: Czechoslovak catalogue for construction 14/5 Radiators, basic advice for 1991
Heat output of sectional radiators
The company reserves the right to make technical changes.
Sectional radiators
[mm
] Steel panel radiator
cast-iron steel RadiK KLaSiK - R
575 ÷ 610 575 ÷ 610 H 554
500 500 h 500
110 160 220 200 150 200 B 66 66 100 155
500/110 500/160 500/220 500/200 500/150 500/200 type 20 R 21 R 22 R 33 R
number of sections n [pcs]
number of sections n [pcs]
appropriate length of the radiator L [mm]
5 3 3 3 5 4 400
6 4 3 4 6 5 500 400
7 5 4 4 7 5 600 400 400
8 6 5 5 8 7 700 500 400
10 7 6 7 10 8 800 600 500
11 8 6 7 11 9 900 700 500 400
12 9 7 8 12 10 1000 800 600 400
13 10 8 9 13 11 1100 800 700 500
15 11 9 10 15 12 1200 900 700 500
16 12 10 11 16 14 1400 1000 800 600
17 13 10 12 17 14 1400 1100 800 600
18 14 11 12 18 15 1600 1100 900 600
20 15 12 13 20 16 1600 1200 900 700
22 16 13 15 22 18 1800 1400 1000 700
24 18 14 16 24 19 2000 1400 1100 800
25 19 15 17 25 21 2000 1600 1200 800
26 20 15 17 26 22 2300 1600 1200 900
29 22 17 20 29 24 2300 1800 1400 1000
30 23 18 20 30 25 2600 1800 1400 1000
33 25 20 22 33 27 2600 2000 1600 1100
35 26 21 23 35 28 3000 2300 1600 1100
38 28 23 26 38 31 3000 2300 1800 1200
38 29 23 26 38 31 3000 2300 1800 1400
40 30 23 26 40 32 2600 1800 1400
44 33 26 29 44 36 2600 2000 1400
50 38 30 34 50 41 3000 2300 1600
57 43 34 38 57 46 2600 1800
64 48 38 43 64 51 3000 2000
66 50 39 44 66 54 3000 2300
You can find a replacement for your cast-iron and steel sectional radiators yourself in the RadiK KLaSiK – R steel panel radiator range
1. 1.
3.
5.
3.
5.
7.
9.
2. 2.
4.
4.
6.
8.
material of radiator connecting pitch h [mm] depth B [mm] heat output [W/section]
(90/70/20 °C)
steel 500
150 90160 93200 110220 121
cast-iron 500
110 92150 107160 120200 134220 151250 169
identification of the old radiator:Determine material (cast-iron/steel)*
Measure the height of the radiator H
Check whether the connecting pitch h is 500 mm
Measure the depth of the radiator B
Count the number of sections (“ribs”)
Looking for a replacement in the table:According to identification (see above), look in the left part of the table for the appropriate column, corresponding to the type of the old radiator
Find the row with the appropri-ate number of sections n (if the precise number is not shown in the table, choose the next highest)
Select the most suitable length for the new steel panel radiator L in the row with the appropriate num-ber of sections in the right (blue) part of the table (this depends on the type of steel panel radiator).
After selecting the type of steel pa-nel radiator, once again check its depth B, to see whether it meets your requirements
H [mm] - height of the radiatorh [mm] - connecting pitchL [mm] - length of the radiator B [mm] - depth of the radiator
* if the surface of your sectional radiator is rough, you have a cast-iron radiator
H
h
LB
tECH
niC
aL
da
ta, O
vER
viE
W O
F tY
PES
The company reserves the right to make technical changes.
KLASIK - R FinishThe technology used guarantees the achievement of threebasic goals:
• long-term corrosion resistance and mechanical durability• fine-quality finish• hygienic surface
The surface finish is done in three basic phases:
1) Preparation of the steel surface – includes degreasing,phosphating, and rinsing in three stages.
2) Putting on the first layer of paint using the cataphoreticmethod (KTL). The layer of paint is evenly spread over the whole radiator. The KTL paint gains its final anticorrosion, adhesive, and mechanical and chemical characteristics in a drying oven. This phase of surface finishing is of decisive importance for the long life span of the radiator.
3) Putting on the final layer of paint – epoxy-polyester powder is applied using automatic dusting pistols in an electrostatic field of a dusting compartment. After it is oven dried and cooled, the finish of the radiator is completed.
The surface finishing of the radiators is done with a maximum effort to protect the environment, during production and use.
Radiators are delivered in white powder coat RAL 9016 as standard, on request also in other colours. For more information on the colours available see please the colour card.
Degreasing and phosphating
Cataphoresic paint
Epoxy-polyester powder
Colour card
1.
1.
3.
3.
2.
2.
notice: The colour of the radiator may vary in comparison with the colour shown in the colour card. *Irregular pigment of Colours coded 29 and 30 is their natural feature. The standard paint finish is white RAL 9016,other colours are available at an extra charge.Surcharge: RadiK +30%
Fin
iSH
, CO
LOU
R C
aRd
The company reserves the right to make technical changes.
KLASIK - R
description Overview of types
The RadiK KLaSiK – R model is a steel panel radiator in KLASIK design, modified for swift replacement of cast-iron sectional radiators with a connecting pitch of 500 mm.
The height H = 554 mm guarantees its problem-free fitting in place of the old radiator. It allows for left or right side connection to the heating system distribution mains and is designed for heating systems with forced or gravity circulation. Two upper and lower fixing lugs are welded onto the back, radiators 1800 mm in length or longer have six welded fixing lugs.
The wide range of types of RADIK KLASIK - R allows you to always choose the most suitable and appropriate length.
All radiators are supplied with:• an air vent• a blanking plug• upper grille• side covers
Height H 554 mm
Length L
400, 500, 600, 700, 800, 900, 1000, 1100, 1200,
1400, 1600, 1800, 2000, 2300, 2600, 3000 mm
depth BTyp 20 RTyp 21 RTyp 22 RTyp 33 R
66 mm66 mm
100 mm155 mm
Connecting pitch 500 mm
Connecting thread 4 x G1/2 inside
Highest allowed working pressure
10 bar
test pressure 13 bar
Highest allowed working temperature
110 °C
Basic paint KTL
Surface paint white RAL 9016
guarantee period 10 years
Radiator connection left or right side
side – one sideϕ = 1
side – two sides diagonalϕ = 1recommended for: L ≥ 3 x H
Examples of connection to the heating system
Y
X1
X2
600500
type 20 R
type 21 R
type 22 R
type 33 R
H
L
BB
BB
h
technical data
50
0
50
0
The company reserves the right to make technical changes.
20 °C typ 20 R typ 21 R typ 22 R typ 33 R
Length L [mm]
t1/t2
[°C]
Height H [mm]
554 554 554 554
400
90/70 460 612 798 114375/65 366 484 630 90370/55 293 386 503 72055/45 187 243 316 452
500
90/70 575 765 997 142875/65 457 605 788 112970/55 366 483 628 90055/45 233 304 395 566
600
90/70 690 918 1196 171475/65 548 726 946 135470/55 440 579 754 107955/45 280 365 474 679
700
90/70 805 1071 1396 200075/65 640 847 1103 158070/55 513 676 880 125955/45 327 426 554 792
800
90/70 920 1224 1595 228575/65 731 968 1261 180670/55 586 772 1005 143955/45 373 487 633 905
900
90/70 1035 1377 1795 257175/65 823 1089 1418 203170/55 660 869 1131 161955/45 420 548 712 1018
1000
90/70 1150 1530 1994 285775/65 914 1210 1576 225770/55 733 966 1257 179955/45 467 608 791 1131
1100
90/70 1265 1683 2193 314275/65 1005 1331 1734 248370/55 806 1062 1382 197955/45 513 669 870 1244
1200
90/70 1380 1836 2393 342875/65 1097 1452 1891 270870/55 880 1159 1508 215955/45 560 730 949 1357
1400
90/70 1609 2142 2792 399975/65 1280 1694 2206 316070/55 1026 1352 1759 251955/45 653 852 1107 1584
1600
90/70 1839 2448 3190 457175/65 1462 1936 2522 361170/55 1173 1545 2011 287855/45 747 974 1265 1810
1800
90/70 2069 2754 3589 514275/65 1645 2178 2837 406370/55 1319 1738 2262 323855/45 840 1095 1423 2036
2000
90/70 2299 3059 3988 571375/65 1828 2420 3152 451470/55 1466 1931 2513 359855/45 933 1217 1581 2262
2300
90/70 2644 3518 4586 657075/65 2102 2783 3625 519170/55 1686 2221 2890 413855/45 1073 1400 1819 2602
2600
90/70 2989 3977 5184 742775/65 2376 3146 4098 586870/55 1906 2510 3267 467855/45 1213 1582 2056 2941
3000
90/70 3449 4589 5982 857075/65 2742 3630 4728 677170/55 2199 2897 3770 539755/45 1400 1825 2372 3394
Heat output according to En 442 description of how to order radiators Colour card
Model type Code for ordering
RadiK KLaSiK-R
20 R 20-HHHLLL-R0-10
21 R 21-HHHLLL-R0-10
22 R 22-HHHLLL-R0-10
33 R 33-HHHLLL-R0-10
table for creation of a code
Example for creation of a code
RadiK KLaSiK - R steel panel radiator.type 22, height H = 554 mm , length L = 1800 mm, Colour White RAL 9016
Correct code: 22-HHHLLL-R0-10 22-055180-R0-10
KLASIK - R
22-HHHLLL-R0-10Colour code Additional informationModel numberLength in cmHeight in cmType number
tECH
niC
aL
da
ta, O
vER
viE
W O
F tY
PES
The company reserves the right to make technical changes.
KLASIK - R FinishThe technology used guarantees the achievement of threebasic goals:
• long-term corrosion resistance and mechanical durability• fine-quality finish• hygienic surface
The surface finish is done in three basic phases:
1) Preparation of the steel surface – includes degreasing,phosphating, and rinsing in three stages.
2) Putting on the first layer of paint using the cataphoreticmethod (KTL). The layer of paint is evenly spread over the whole radiator. The KTL paint gains its final anticorrosion, adhesive, and mechanical and chemical characteristics in a drying oven. This phase of surface finishing is of decisive importance for the long life span of the radiator.
3) Putting on the final layer of paint – epoxy-polyester powder is applied using automatic dusting pistols in an electrostatic field of a dusting compartment. After it is oven dried and cooled, the finish of the radiator is completed.
The surface finishing of the radiators is done with a maximum effort to protect the environment, during production and use.
Radiators are delivered in white powder coat RAL 9016 as standard, on request also in other colours. For more information on the colours available see please the colour card.
Degreasing and phosphating
Cataphoresic paint
Epoxy-polyester powder
Colour card
1.
1.
3.
3.
2.
2.
notice: The colour of the radiator may vary in comparison with the colour shown in the colour card. *Irregular pigment of Colours coded 29 and 30 is their natural feature. The standard paint finish is white RAL 9016,other colours are available at an extra charge.Surcharge: RadiK +30%
Fin
iSH
, CO
LOU
R C
aRd
The company reserves the right to make technical changes.
KLASIK - R
description Overview of types
The RadiK KLaSiK – R model is a steel panel radiator in KLASIK design, modified for swift replacement of cast-iron sectional radiators with a connecting pitch of 500 mm.
The height H = 554 mm guarantees its problem-free fitting in place of the old radiator. It allows for left or right side connection to the heating system distribution mains and is designed for heating systems with forced or gravity circulation. Two upper and lower fixing lugs are welded onto the back, radiators 1800 mm in length or longer have six welded fixing lugs.
The wide range of types of RADIK KLASIK - R allows you to always choose the most suitable and appropriate length.
All radiators are supplied with:• an air vent• a blanking plug• upper grille• side covers
Height H 554 mm
Length L
400, 500, 600, 700, 800, 900, 1000, 1100, 1200,
1400, 1600, 1800, 2000, 2300, 2600, 3000 mm
depth BTyp 20 RTyp 21 RTyp 22 RTyp 33 R
66 mm66 mm
100 mm155 mm
Connecting pitch 500 mm
Connecting thread 4 x G1/2 inside
Highest allowed working pressure
10 bar
test pressure 13 bar
Highest allowed working temperature
110 °C
Basic paint KTL
Surface paint white RAL 9016
guarantee period 10 years
Radiator connection left or right side
side – one sideϕ = 1
side – two sides diagonalϕ = 1recommended for: L ≥ 3 x H
Examples of connection to the heating system
Y
X1
X2
600500
type 20 R
type 21 R
type 22 R
type 33 R
H
L
BB
BB
h
technical data
50
0
50
0
The company reserves the right to make technical changes.
20 °C typ 20 R typ 21 R typ 22 R typ 33 R
Length L [mm]
t1/t2
[°C]
Height H [mm]
554 554 554 554
400
90/70 460 612 798 114375/65 366 484 630 90370/55 293 386 503 72055/45 187 243 316 452
500
90/70 575 765 997 142875/65 457 605 788 112970/55 366 483 628 90055/45 233 304 395 566
600
90/70 690 918 1196 171475/65 548 726 946 135470/55 440 579 754 107955/45 280 365 474 679
700
90/70 805 1071 1396 200075/65 640 847 1103 158070/55 513 676 880 125955/45 327 426 554 792
800
90/70 920 1224 1595 228575/65 731 968 1261 180670/55 586 772 1005 143955/45 373 487 633 905
900
90/70 1035 1377 1795 257175/65 823 1089 1418 203170/55 660 869 1131 161955/45 420 548 712 1018
1000
90/70 1150 1530 1994 285775/65 914 1210 1576 225770/55 733 966 1257 179955/45 467 608 791 1131
1100
90/70 1265 1683 2193 314275/65 1005 1331 1734 248370/55 806 1062 1382 197955/45 513 669 870 1244
1200
90/70 1380 1836 2393 342875/65 1097 1452 1891 270870/55 880 1159 1508 215955/45 560 730 949 1357
1400
90/70 1609 2142 2792 399975/65 1280 1694 2206 316070/55 1026 1352 1759 251955/45 653 852 1107 1584
1600
90/70 1839 2448 3190 457175/65 1462 1936 2522 361170/55 1173 1545 2011 287855/45 747 974 1265 1810
1800
90/70 2069 2754 3589 514275/65 1645 2178 2837 406370/55 1319 1738 2262 323855/45 840 1095 1423 2036
2000
90/70 2299 3059 3988 571375/65 1828 2420 3152 451470/55 1466 1931 2513 359855/45 933 1217 1581 2262
2300
90/70 2644 3518 4586 657075/65 2102 2783 3625 519170/55 1686 2221 2890 413855/45 1073 1400 1819 2602
2600
90/70 2989 3977 5184 742775/65 2376 3146 4098 586870/55 1906 2510 3267 467855/45 1213 1582 2056 2941
3000
90/70 3449 4589 5982 857075/65 2742 3630 4728 677170/55 2199 2897 3770 539755/45 1400 1825 2372 3394
Heat output according to En 442 description of how to order radiators Colour card
Model type Code for ordering
RadiK KLaSiK-R
20 R 20-HHHLLL-R0-10
21 R 21-HHHLLL-R0-10
22 R 22-HHHLLL-R0-10
33 R 33-HHHLLL-R0-10
table for creation of a code
Example for creation of a code
RadiK KLaSiK - R steel panel radiator.type 22, height H = 554 mm , length L = 1800 mm, Colour White RAL 9016
Correct code: 22-HHHLLL-R0-10 22-055180-R0-10
KLASIK - R
22-HHHLLL-R0-10Colour code Additional informationModel numberLength in cmHeight in cmType number
Replace your old radiators with new ones!
Steel panel radiators for renovation jobs, suitable for replacement of cast-iron or steel sectional radiators.
KLASIK - R
CE mark used from the year 2005
03/2011
10YEAR
GUARANTEE Fitt
ing
da
ta
The company reserves the right to make technical changes.01/11.670.1 EN
KLASIK - RFitting data
Z-U140 bracket
Z-U290 bracket
Fitting data
Basic technical data
The Z-U140 bracket can be used for fixing the radiator at a fixed distance of the radiator from the wall of 48 mm, or the Z-U290 bracket with variable distance of up to 100 mm from the wall.
27
68
X3 X5
399
90
X4(L)
(H)
25
554
85
X1
X2
500
399
71
554
X1
X2
500
50
0 22
85
27
55
4
X2
centre line of the lower connection pipe
centre line of the upper connection pipe
X1
48120
68
X3 X5
399
90
X4(L)
(H)
25
554
85
X1
X2
500
399
71
554
X1
X2
500
50
0 8
39
97
1
27
27
55
4
X2
centre line of the lower connection pipe
centre line of the upper connection pipe
X1
100115
type 20 R 21 R 22 R 33 R
X1 81 81 98 98
X2 114 114 148 203
type 20 R 21 R 22 R 33 R
HeightH [mm] 554 554 554 554
Radiator weight [kg/m]
22,6 28,0 34,6 52,4
Water volume[l/m]
5,5 5,5 5,5 8,2
Flow coefficient
at [m2]
1,0 x 10 -4
(DN 15)1,0 x 10 -4
(DN 15)1,0 x 10 -4
(DN 15)1,18 x 10 -4
(DN 15)
Resistance coefficient
ξt [-]8,5 (DN 15) 8,5 (DN 15) 8,5 (DN 15) 5,8 (DN 15)
Standard heat output[W/m]
914 1210 1576 2257
temperature exponent
n [-]1,3010 1,3300 1,3344 1,3364
type 20 R 21 R 22 R 33 R
X1 133 133 150 150
X2 166 166 200 255
X2
X1
500
2773
600
Y
68
25
X3X4 X5
(L)
445
25
90
(H)
39
9
68
X3X5X4
(L)
Length L [mm]
400 500 ÷ 1600 1800 2000 2300 2600 3000
X3 133 133 133 133 133 133 133
X4 - - 900 1000 1133 1300 1500
X5 133 133 133 133 133 133 133
Manufactured by:
KORADO, a. s.Bří Hubálků 869, 560 02 Česká TřebováCzech RepublicE-Mail: [email protected]://www.korado.comPR
OCE
dU
RE F
OR
REPL
aCE
MEn
t O
F Ra
dia
tORS
KLASIK - R
Source of information: Czechoslovak catalogue for construction 14/5 Radiators, basic advice for 1991
Heat output of sectional radiators
The company reserves the right to make technical changes.
Sectional radiators
[mm
] Steel panel radiator
cast-iron steel RadiK KLaSiK - R
575 ÷ 610 575 ÷ 610 H 554
500 500 h 500
110 160 220 200 150 200 B 66 66 100 155
500/110 500/160 500/220 500/200 500/150 500/200 type 20 R 21 R 22 R 33 R
number of sections n [pcs]
number of sections n [pcs]
appropriate length of the radiator L [mm]
5 3 3 3 5 4 400
6 4 3 4 6 5 500 400
7 5 4 4 7 5 600 400 400
8 6 5 5 8 7 700 500 400
10 7 6 7 10 8 800 600 500
11 8 6 7 11 9 900 700 500 400
12 9 7 8 12 10 1000 800 600 400
13 10 8 9 13 11 1100 800 700 500
15 11 9 10 15 12 1200 900 700 500
16 12 10 11 16 14 1400 1000 800 600
17 13 10 12 17 14 1400 1100 800 600
18 14 11 12 18 15 1600 1100 900 600
20 15 12 13 20 16 1600 1200 900 700
22 16 13 15 22 18 1800 1400 1000 700
24 18 14 16 24 19 2000 1400 1100 800
25 19 15 17 25 21 2000 1600 1200 800
26 20 15 17 26 22 2300 1600 1200 900
29 22 17 20 29 24 2300 1800 1400 1000
30 23 18 20 30 25 2600 1800 1400 1000
33 25 20 22 33 27 2600 2000 1600 1100
35 26 21 23 35 28 3000 2300 1600 1100
38 28 23 26 38 31 3000 2300 1800 1200
38 29 23 26 38 31 3000 2300 1800 1400
40 30 23 26 40 32 2600 1800 1400
44 33 26 29 44 36 2600 2000 1400
50 38 30 34 50 41 3000 2300 1600
57 43 34 38 57 46 2600 1800
64 48 38 43 64 51 3000 2000
66 50 39 44 66 54 3000 2300
You can find a replacement for your cast-iron and steel sectional radiators yourself in the RadiK KLaSiK – R steel panel radiator range
1. 1.
3.
5.
3.
5.
7.
9.
2. 2.
4.
4.
6.
8.
material of radiator connecting pitch h [mm] depth B [mm] heat output [W/section]
(90/70/20 °C)
steel 500
150 90160 93200 110220 121
cast-iron 500
110 92150 107160 120200 134220 151250 169
identification of the old radiator:Determine material (cast-iron/steel)*
Measure the height of the radiator H
Check whether the connecting pitch h is 500 mm
Measure the depth of the radiator B
Count the number of sections (“ribs”)
Looking for a replacement in the table:According to identification (see above), look in the left part of the table for the appropriate column, corresponding to the type of the old radiator
Find the row with the appropri-ate number of sections n (if the precise number is not shown in the table, choose the next highest)
Select the most suitable length for the new steel panel radiator L in the row with the appropriate num-ber of sections in the right (blue) part of the table (this depends on the type of steel panel radiator).
After selecting the type of steel pa-nel radiator, once again check its depth B, to see whether it meets your requirements
H [mm] - height of the radiatorh [mm] - connecting pitchL [mm] - length of the radiator B [mm] - depth of the radiator
* if the surface of your sectional radiator is rough, you have a cast-iron radiator
H
h
LB