Download - L35 3ph im
![Page 1: L35 3ph im](https://reader035.vdocument.in/reader035/viewer/2022081412/54138a638d7f7284698b4651/html5/thumbnails/1.jpg)
ELE 101 / 102 Basic Electrical Technology Dept of E & E, MIT Manipal
3 Phase Induction Motor - Introduction
•Converts electrical power into mechanical
power
•Energy transfer by means of electromagnetic
induction
• Industrial & Commercial Applications Pumping Systems
Refrigeration Systems
Compressors
Fans & Blowers
Industrial Drives
![Page 2: L35 3ph im](https://reader035.vdocument.in/reader035/viewer/2022081412/54138a638d7f7284698b4651/html5/thumbnails/2.jpg)
Rotating Magnetic Field
• 3 phase supply is given to a balanced 3 phase winding.
• 3 alternating magnetic fluxes displaced mutually at 120o is produced.
240)t(sinφφ
120)t(sinφφ
tsinφφ
maxB
maxY
maxR
![Page 3: L35 3ph im](https://reader035.vdocument.in/reader035/viewer/2022081412/54138a638d7f7284698b4651/html5/thumbnails/3.jpg)
Considering different instances of time:
(i) At wt = 0o
The instantaneous fluxes are
The resultant magnetic flux is 1.5 times peak value and
Acting at 90o to axis of reference.
maxB
maxY
R
φ866.0φ
φ866.0φ
0φ
![Page 4: L35 3ph im](https://reader035.vdocument.in/reader035/viewer/2022081412/54138a638d7f7284698b4651/html5/thumbnails/4.jpg)
(ii) At wt = 60o
The instantaneous fluxes are
The resultant magnetic flux is
1.5 times peak value and acting
at 30o to axis of reference.
i.e., rotated by 60o w.r.t. previous angle
0φ
φ866.0φ
φ866.0φ
B
maxY
maxR
![Page 5: L35 3ph im](https://reader035.vdocument.in/reader035/viewer/2022081412/54138a638d7f7284698b4651/html5/thumbnails/5.jpg)
Similarly if various instances are considered upto 360o, it is seen that the resultant always has a magnitude of 1.5 times peak value and pointing in a direction at the angle of consideration.
For every 360o, the resultant magnetic field completes one rotation.
Inference:When 3 phase currents flow in a balanced 3 phase winding, a
rotating magnetic field is created which has constant magnitude, but rotates in synchronism with supply frequency.
This speed of rotating magnetic field is called SYNCHRONOUS SPEED
P
fNS
120
![Page 6: L35 3ph im](https://reader035.vdocument.in/reader035/viewer/2022081412/54138a638d7f7284698b4651/html5/thumbnails/6.jpg)
ELE 101 / 102 Basic Electrical Technology Dept of E & E, MIT Manipal
Classification
• Construction
Squirrel Cage, Slip Ring
• Connection Stator : Star, Delta
Rotor : Cage, Wound
• Application Constant Power, Constant Torque, Constant Speed,
Variable Torque - Variable Speed
![Page 7: L35 3ph im](https://reader035.vdocument.in/reader035/viewer/2022081412/54138a638d7f7284698b4651/html5/thumbnails/7.jpg)
ELE 101 / 102 Basic Electrical Technology Dept of E & E, MIT Manipal
Cross Sectional View
Terminal Box
Outer Frame
Stator
Cage Rotor
Shaft
Ball Bearings
Supporting Base
![Page 8: L35 3ph im](https://reader035.vdocument.in/reader035/viewer/2022081412/54138a638d7f7284698b4651/html5/thumbnails/8.jpg)
ELE 101 / 102 Basic Electrical Technology Dept of E & E, MIT Manipal
Construction – Stator
• Stator frame: Cast Iron, Mechanical Support to stator core• Stator core: Stack of cylindrical steel laminations• Stator Slots: Inner periphery, Windings
Slots
Stator Conductors
Laminations
Outer frame
Stator Core
Stator Slots
Stator windings
![Page 9: L35 3ph im](https://reader035.vdocument.in/reader035/viewer/2022081412/54138a638d7f7284698b4651/html5/thumbnails/9.jpg)
ELE 101 / 102 Basic Electrical Technology Dept of E & E, MIT Manipal
Construction – Rotor
• Types on the basis of rotor
construction Squirrel Cage Rotor
Slip Ring Rotor
• Cylindrical Laminated core
• Slots cutout on outer periphery
• Conductors placed in slots
![Page 10: L35 3ph im](https://reader035.vdocument.in/reader035/viewer/2022081412/54138a638d7f7284698b4651/html5/thumbnails/10.jpg)
ELE 101 / 102 Basic Electrical Technology Dept of E & E, MIT Manipal
Construction – Squirrel cage Rotor
• Skewed arrangement
• Copper or Aluminum Bars
• Conductors shorted by end
rings
• Closed rotor circuit
Rotor bars
End rings
![Page 11: L35 3ph im](https://reader035.vdocument.in/reader035/viewer/2022081412/54138a638d7f7284698b4651/html5/thumbnails/11.jpg)
ELE 101 / 102 Basic Electrical Technology Dept of E & E, MIT Manipal
Construction – Slip ring rotor
• One end of Rotor conductors connected to each other
(Star)
Rotor
External resistance
Shaft
• Other ends connected to slip rings• Slip rings in contact with brushes
• Brushes connected to external resistance
Slip ringsRotor
Conductors
Brush
![Page 12: L35 3ph im](https://reader035.vdocument.in/reader035/viewer/2022081412/54138a638d7f7284698b4651/html5/thumbnails/12.jpg)
Representation
ELE 101 / 102 Basic Electrical Technology Dept of E & E, MIT Manipal L1 – 15
3Ø Supply
Stator Core
Stator SlotsStator conductors
Rotor conductorsRotor SlotsRotor CoreShaft