Leak tests
G. Apeldoorn, P. Vankov
29.01.2004, NIKHEF
![Page 2: Leak tests G. Apeldoorn, P. Vankov 29.01.2004, NIKHEF](https://reader035.vdocument.in/reader035/viewer/2022062409/5697c01a1a28abf838ccedf0/html5/thumbnails/2.jpg)
Leak tests 29.01.2004
Tests are based on using:
AFS 1400 – Bidirectional Mass Flow Meter
Characteristics of AFS 1400:
- dynamic range: 0.03 – 400 sccm
-Fast response time: 150 ms
-Calibrated & Temperature compensated (for air & Nitrogen)
-Digital output signal (RS-232)
(http://www.sensirion.com)
![Page 3: Leak tests G. Apeldoorn, P. Vankov 29.01.2004, NIKHEF](https://reader035.vdocument.in/reader035/viewer/2022062409/5697c01a1a28abf838ccedf0/html5/thumbnails/3.jpg)
Leak tests 29.01.2004
Flowmeter
opened
F1: 1.023e-6 l/s
F2: -1.621e-7 l/s
F3: -1.391e-7 l/s
F4: 1.057e-7 l/s
![Page 4: Leak tests G. Apeldoorn, P. Vankov 29.01.2004, NIKHEF](https://reader035.vdocument.in/reader035/viewer/2022062409/5697c01a1a28abf838ccedf0/html5/thumbnails/4.jpg)
Leak tests 29.01.2004
Flowmeter
shorted
F1: 1.014e-6 l/s
F2: -1.441e-7 l/s
F3: -1.244e-7 l/s
F4: 8.529e-8 l/s
![Page 5: Leak tests G. Apeldoorn, P. Vankov 29.01.2004, NIKHEF](https://reader035.vdocument.in/reader035/viewer/2022062409/5697c01a1a28abf838ccedf0/html5/thumbnails/5.jpg)
Leak tests 29.01.2004
Flowmeter
Flowmeter
Temperatures
![Page 6: Leak tests G. Apeldoorn, P. Vankov 29.01.2004, NIKHEF](https://reader035.vdocument.in/reader035/viewer/2022062409/5697c01a1a28abf838ccedf0/html5/thumbnails/6.jpg)
Leak tests 29.01.2004
Connection in series
“Brooks” mass flow controller
![Page 7: Leak tests G. Apeldoorn, P. Vankov 29.01.2004, NIKHEF](https://reader035.vdocument.in/reader035/viewer/2022062409/5697c01a1a28abf838ccedf0/html5/thumbnails/7.jpg)
Leak tests 29.01.2004
Leak test of Module 5012 (5m prototype)
(N)
Flow meter
F1
Bubbler
(8 mbar)
closed
Module12
Steps:
0. Tap 2 is always closed.
1. Tap 1 is opened, gas is pumping the module in.
2. Tap 1 is closed, module is under 8 mbar overpressure, F1 is measuring.
Leakage criterion:
Leakage flow must be of the order (or less) of 1e-6 l/s.
![Page 8: Leak tests G. Apeldoorn, P. Vankov 29.01.2004, NIKHEF](https://reader035.vdocument.in/reader035/viewer/2022062409/5697c01a1a28abf838ccedf0/html5/thumbnails/8.jpg)
Leak tests 29.01.2004
![Page 9: Leak tests G. Apeldoorn, P. Vankov 29.01.2004, NIKHEF](https://reader035.vdocument.in/reader035/viewer/2022062409/5697c01a1a28abf838ccedf0/html5/thumbnails/9.jpg)
Leak tests 29.01.2004
Flow meter
F1
ModuleF2
Flow meter
straw
straw
straw
straw
outer
outer outer
outer
Gas
Gas volumes (straw/outer) separation
![Page 10: Leak tests G. Apeldoorn, P. Vankov 29.01.2004, NIKHEF](https://reader035.vdocument.in/reader035/viewer/2022062409/5697c01a1a28abf838ccedf0/html5/thumbnails/10.jpg)
Leak tests 29.01.2004
Gas volumes (straw/outer) separation
Flow meter
F1
ModuleF2
Flow meter
straw
straw
straw
straw
outer
outer outer
outer
Gas
![Page 11: Leak tests G. Apeldoorn, P. Vankov 29.01.2004, NIKHEF](https://reader035.vdocument.in/reader035/viewer/2022062409/5697c01a1a28abf838ccedf0/html5/thumbnails/11.jpg)
Leak tests 29.01.2004
How to proceed ?
-Better tubes & taps
-Atmospheric pressure & temperature monitoring
-Flow controller
-Nitrogen/Argon