LEL ReductionUsing
Gold CrewVapor Lock
About 3 gallons of Gold Crew Vapor Lock are added to a pressure washer tank with
about 300 gallons of water in it
The solution is then re-circulated through the wand to make
sure that the product is mixed evenly
Top of 6000 gallon resin tank
Fill pipe
Passage pipe into plant
An 8’ wand with a 90° nozzle is used to spray the
Vapor Lock solution into the tank
LEL is checked to see if work can continue in the confined space
Levels were too high for meter to read
The wand was inserted into the fill hole because the opening in near the top of
the tank. The wand is turned to make sure that the spray covers the entire tank to
knock down vapors.
About 20 gallons of the 1% solution is used
A Meter reading of 0 LEL after spraying tank with Gold Crew Vapor Lock
Levels are checked one more time before work continues. LEL was zero.