Transcript
Page 1: LUMINAIRE SCHEDULE€¦ · 1755 Telstar Drive, Suite 107 Colorado Springs, Co 80920 719.900.7220 O  2016. Galloway & Company, Inc. All Rights Reserved Date:

1755 Telstar Drive, Suite 107Colorado Springs, Co 80920719.900.7220 Owww.gallowayUS.com

2016. Galloway & Company, Inc. All Rights Reserved

Date:

Drawn By:

Project No:

Checked By:

H:\H

amm

ers

Con

stru

ctio

nIn

c\C

O,E

lPas

oC

ount

y-H

CI0

0000

3.01

-Cra

cker

jack

\CAD

D\3

-CD

\DW

G\H

CI0

3_C

3.1-

Lite

.dw

g-R

yan

Gra

ham

-6/2

6/20

17

HCI003.1

JUNE 2017

Init.# Issue / DescriptionDate

CO

NS

TRU

CTI

ON

DO

CU

ME

NTS

CR

ACKE

RJA

CK

MU

DJA

CKI

NG

INC

.C

BP,F

2-L

OT

#21

SW

CO

RN

ERO

FM

cCLA

INPT

&C

OLE

VWC

OLO

RAD

OSP

RIN

GS,

CO

THESE PLANS ARE AN INSTRUMENT OFSERVICE AND ARE THE PROPERTY OFGALLOWAY, AND MAY NOT BE DUPLICATED,DISCLOSED, OR REPRODUCED WITHOUTTHE WRITTEN CONSENT OF GALLOWAY.COPYRIGHTS AND INFRINGEMENTS WILLBE ENFORCED AND PROSECUTED.

COPYRIGHT

NOT FOR

CONSTRUCTION

00 06/XX/17 AGENCY SUBMITTAL TAC

SCALE: 1"=10'

0 5 10

JMG

TAC

PHOTOMETRIC PLAN

C3.1

CAUTION - NOTICE TO CONTRACTOR1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS

PROVIDED BY THE APPROPRIATE UTILITY COMPANY ANDFIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TOBE CONSIDERED AN APPROXIMATE LOCATION ONLY. IT IS THECONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE FIELDLOCATION OF ALL UTILITIES, PUBLIC OR PRIVATE, WHETHERSHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION.REPORT ANY DISCREPANCIES TO THE ENGINEER PRIOR TOCONSTRUCTION.

2. WHERE A PROPOSED UTILITY CROSSES AN EXISTING UTILITY,IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFYTHE HORIZONTAL AND VERTICAL LOCATION OF SUCHEXISTING UTILITY, EITHER THROUGH POTHOLING ORALTERNATIVE METHOD. REPORT INFORMATION TO THEENGINEER PRIOR TO CONSTRUCTION.

LUMINAIRE SCHEDULESYMBOL QTY LABEL MOUNTING LLF CATALOG NUMBER WATTS LUMENS

6 2 WALL @ 15'-6" 1.0 WST LED P3 40K VF MVOLT DDBXD 50 6610

2 1 WALL @ 8'-0" 1.0 WST LED P1 40K VW MVOLT E20WC DDBXD 12 1659

DESCRIPTION

LITHONIA LIGHTING, WST LED ARCHITECTURAL WALL SCONCE, LUMEN PACKAGE P3, 4000K COLOR TEMPERATURE,

LITHONIA LIGHTING, WST LED ARCHITECTURAL WALL SCONCE, LUMEN PACKAGE P1, 4000K COLOR TEMPERATURE,VISUAL COMFORT WIDE THROW, EMERGENCY BATTERY BACKUP-COLD, BRONZE COLOR

2 VISUAL COMFORT FORWARD THROW, BRONZE COLOR

PHOTOMETRIC SITE PLAN1 SCALE: 1"=10'-0"

2

2

2 2 1 22

1

Page 2: LUMINAIRE SCHEDULE€¦ · 1755 Telstar Drive, Suite 107 Colorado Springs, Co 80920 719.900.7220 O  2016. Galloway & Company, Inc. All Rights Reserved Date:

1755 Telstar Drive, Suite 107Colorado Springs, Co 80920719.900.7220 Owww.gallowayUS.com

2016. Galloway & Company, Inc. All Rights Reserved

Date:

Drawn By:

Project No:

Checked By:

H:\H

amm

ers

Con

stru

ctio

nIn

c\C

O,E

lPas

oC

ount

y-H

CI0

0000

3.01

-Cra

cker

jack

\CAD

D\3

-CD

\DW

G\H

CI0

3_C

3.2-

Lite

Det

s.dw

g-R

yan

Gra

ham

-6/2

6/20

17

HCI003.1

JUNE 2017

Init.# Issue / DescriptionDate

CO

NS

TRU

CTI

ON

DO

CU

ME

NTS

CR

ACKE

RJA

CK

MU

DJA

CKI

NG

INC

.C

BP,F

2-L

OT

#21

SW

CO

RN

ERO

FM

cCLA

INPT

&C

OLE

VWC

OLO

RAD

OSP

RIN

GS,

CO

THESE PLANS ARE AN INSTRUMENT OFSERVICE AND ARE THE PROPERTY OFGALLOWAY, AND MAY NOT BE DUPLICATED,DISCLOSED, OR REPRODUCED WITHOUTTHE WRITTEN CONSENT OF GALLOWAY.COPYRIGHTS AND INFRINGEMENTS WILLBE ENFORCED AND PROSECUTED.

COPYRIGHT

NOT FOR

CONSTRUCTION

00 06/XX/17 AGENCY SUBMITTAL TAC

JMG

TAC

PHOTOMETRIC DETAILS

C3.2

MANUFACTURER SPECIFICATION SHEET FOR WALL FIXTURES "1" & "2"

1

21

2

1


Top Related