Download - Mammalian Cell Culture Sensors and Models
![Page 1: Mammalian Cell Culture Sensors and Models](https://reader038.vdocument.in/reader038/viewer/2022102719/56814c5b550346895db97b2b/html5/thumbnails/1.jpg)
Mammalian Cell CultureSensors and Models
Mammalian Cell CultureSensors and Models
Trish Benton Michael Boudreau
![Page 2: Mammalian Cell Culture Sensors and Models](https://reader038.vdocument.in/reader038/viewer/2022102719/56814c5b550346895db97b2b/html5/thumbnails/2.jpg)
PresentersPresenters
Trish Benton
Michael Boudreau
![Page 3: Mammalian Cell Culture Sensors and Models](https://reader038.vdocument.in/reader038/viewer/2022102719/56814c5b550346895db97b2b/html5/thumbnails/3.jpg)
483? That means big
trouble
483? That means big
trouble
![Page 4: Mammalian Cell Culture Sensors and Models](https://reader038.vdocument.in/reader038/viewer/2022102719/56814c5b550346895db97b2b/html5/thumbnails/4.jpg)
LandscapeLandscape
New at-line and inline sensors
Concentration Control
ModelingData Analytics
![Page 5: Mammalian Cell Culture Sensors and Models](https://reader038.vdocument.in/reader038/viewer/2022102719/56814c5b550346895db97b2b/html5/thumbnails/5.jpg)
SensorsSensors
At –line Nova, HPLC
In-line Fogale, Aspectrics, Optek, CO2, differential pressure
![Page 6: Mammalian Cell Culture Sensors and Models](https://reader038.vdocument.in/reader038/viewer/2022102719/56814c5b550346895db97b2b/html5/thumbnails/6.jpg)
![Page 7: Mammalian Cell Culture Sensors and Models](https://reader038.vdocument.in/reader038/viewer/2022102719/56814c5b550346895db97b2b/html5/thumbnails/7.jpg)
On-line viable cell densityOn-line viable cell density
In and induced electrical field, an intact cell membranes is a physical barrier to ion migration.
Capacitance measured in picoFarads plotted against the frequency of change of an electrical field, measured in MHz, gives a beta-dispersion spectrum.
![Page 8: Mammalian Cell Culture Sensors and Models](https://reader038.vdocument.in/reader038/viewer/2022102719/56814c5b550346895db97b2b/html5/thumbnails/8.jpg)
Beta Dispersion SpectraBeta Dispersion Spectra
![Page 9: Mammalian Cell Culture Sensors and Models](https://reader038.vdocument.in/reader038/viewer/2022102719/56814c5b550346895db97b2b/html5/thumbnails/9.jpg)
Fogale uses Entire Dielectric SpectrumFogale uses Entire Dielectric Spectrum
Older analyzers measured capacitance at only one frequency.
Newer analyzers use a non-linear least squares fit of random measurements to generate the whole spectrum.
Concentration range: 0 -109 cell/ml for animal cells0 - 200 g/l dry weight for yeast and bacteria
Resolution: 0.01 - 106 cell/ml for animal cells0.02 g/l dry weight for yeast
![Page 10: Mammalian Cell Culture Sensors and Models](https://reader038.vdocument.in/reader038/viewer/2022102719/56814c5b550346895db97b2b/html5/thumbnails/10.jpg)
T3V1 Cell Density
0
5
10
15
20
25
30
Viable Density Capacitance
T1V1 Cell Density
0
5
10
15
20
25
30
35
40
Viable Density Capacitance
![Page 11: Mammalian Cell Culture Sensors and Models](https://reader038.vdocument.in/reader038/viewer/2022102719/56814c5b550346895db97b2b/html5/thumbnails/11.jpg)
Automated Multifunction AnalyzersAutomated Multifunction Analyzers
A robotic combination of enzymatic, amperometric, potentiometric and Coulter counter or CCD camera analyzers.
They can measure:– Sugar and amino acid substrates– Metabolic byproducts– Dissolved Oxygen and Dissolved Carbon Dioxide– pH– Cell Density and viability– Sodium, potassium, calcium, phosphate – “Gold Standard” freezing point test for osmolality.
![Page 12: Mammalian Cell Culture Sensors and Models](https://reader038.vdocument.in/reader038/viewer/2022102719/56814c5b550346895db97b2b/html5/thumbnails/12.jpg)
AutosamplersAutosamplers
Autoclavable, multipoint auto-samplers enable multifunction analyzers to make at-line measurements.
Small sample size allow more frequent analysis. A 5L cell culture bioreactor can be sampled once every 4 hours.
![Page 13: Mammalian Cell Culture Sensors and Models](https://reader038.vdocument.in/reader038/viewer/2022102719/56814c5b550346895db97b2b/html5/thumbnails/13.jpg)
![Page 14: Mammalian Cell Culture Sensors and Models](https://reader038.vdocument.in/reader038/viewer/2022102719/56814c5b550346895db97b2b/html5/thumbnails/14.jpg)
![Page 15: Mammalian Cell Culture Sensors and Models](https://reader038.vdocument.in/reader038/viewer/2022102719/56814c5b550346895db97b2b/html5/thumbnails/15.jpg)
Encoded Photometric Infrared SpectroscopyEncoded Photometric Infrared Spectroscopy
Encoded Photometric infrared analyzers can detect the constituents of multiple frequencies simultaneously
EP IR analyzer is a non-dispersive measurement where the radiation beam is dispersed according to wavelength after it has
passed through a sample
Chemometric analysis is off-line.
![Page 16: Mammalian Cell Culture Sensors and Models](https://reader038.vdocument.in/reader038/viewer/2022102719/56814c5b550346895db97b2b/html5/thumbnails/16.jpg)
EP IR Measurement in Cell CultureEP IR Measurement in Cell Culture
A single analysis function can measure:– Glucose– Glutamine– Glutamate– Proline– Lactic Acid– Ammonia– Dissolved Carbon Dioxide
![Page 17: Mammalian Cell Culture Sensors and Models](https://reader038.vdocument.in/reader038/viewer/2022102719/56814c5b550346895db97b2b/html5/thumbnails/17.jpg)
Concentration ControlConcentration Control
Glucose in high concentration attaches non-specifically to amino acids.
The quality and possibly the quantity of protein product can be increased by maintaining glucose concentration in a bioreactor at physiological levels of about 1 g/L.
![Page 18: Mammalian Cell Culture Sensors and Models](https://reader038.vdocument.in/reader038/viewer/2022102719/56814c5b550346895db97b2b/html5/thumbnails/18.jpg)
Manual Glucose AdditionManual Glucose Addition
Typically glucose is added once a day throughout a cell culture run.
The result is a saw-tooth glucose concentration profile that ranges from 3 g/L to near 0 g/L.
![Page 19: Mammalian Cell Culture Sensors and Models](https://reader038.vdocument.in/reader038/viewer/2022102719/56814c5b550346895db97b2b/html5/thumbnails/19.jpg)
Glucose Addition under Feedback ControlGlucose Addition under Feedback Control
Multifunction analyzers can be used in a feed back loop if the sample time is 25% of the dominant system response time.
In line analyzers, like Fogale viability and EP IR perform analysis on each sample within minutes. Their results can be used in most liquid concentration loops.
![Page 20: Mammalian Cell Culture Sensors and Models](https://reader038.vdocument.in/reader038/viewer/2022102719/56814c5b550346895db97b2b/html5/thumbnails/20.jpg)
Benchtop Bioreactor with SensorsBenchtop Bioreactor with Sensors
Place picture of bioreactor with sensors here
![Page 21: Mammalian Cell Culture Sensors and Models](https://reader038.vdocument.in/reader038/viewer/2022102719/56814c5b550346895db97b2b/html5/thumbnails/21.jpg)
![Page 22: Mammalian Cell Culture Sensors and Models](https://reader038.vdocument.in/reader038/viewer/2022102719/56814c5b550346895db97b2b/html5/thumbnails/22.jpg)
![Page 23: Mammalian Cell Culture Sensors and Models](https://reader038.vdocument.in/reader038/viewer/2022102719/56814c5b550346895db97b2b/html5/thumbnails/23.jpg)
Tuning of Concentration LoopsTuning of Concentration Loops
New concentration
Loops are usually
Integrators.
InSight Learning and
Adaptive Tuning
can identify these
Integrators on in-line
analyzers.
![Page 24: Mammalian Cell Culture Sensors and Models](https://reader038.vdocument.in/reader038/viewer/2022102719/56814c5b550346895db97b2b/html5/thumbnails/24.jpg)
Bio-Process Modeling in Process Development
Bio-Process Modeling in Process Development
High fidelity modeling can help determine the impact of operating conditions on yield and product quality.
![Page 25: Mammalian Cell Culture Sensors and Models](https://reader038.vdocument.in/reader038/viewer/2022102719/56814c5b550346895db97b2b/html5/thumbnails/25.jpg)
Bioprocess Modeling and ControlBioprocess Modeling and Control
Chapter 6 of the book “New Directions in Bioprocess Modeling and Control: Maximizing Process Analytical Technology Benefits” describes in detail how to build a model in DeltaV.
![Page 26: Mammalian Cell Culture Sensors and Models](https://reader038.vdocument.in/reader038/viewer/2022102719/56814c5b550346895db97b2b/html5/thumbnails/26.jpg)
Sequential Modular SimulationSequential Modular Simulation
PumpSimulation
ValveSimulation
ReactorSimulation
Flow measurement
Simulated Properties Flow Temperature Pressure Etc.
Pressuremeasurement Temperature Measurement
Process simulation blocks
![Page 27: Mammalian Cell Culture Sensors and Models](https://reader038.vdocument.in/reader038/viewer/2022102719/56814c5b550346895db97b2b/html5/thumbnails/27.jpg)
Sequential Modular Simulation on DeltaV
Sequential Modular Simulation on DeltaV
jii
i
jii
ji
KX
X
KX
K
jir 21
1
Michaelis-Menten
Rate of synthesis of i by j
![Page 28: Mammalian Cell Culture Sensors and Models](https://reader038.vdocument.in/reader038/viewer/2022102719/56814c5b550346895db97b2b/html5/thumbnails/28.jpg)
Bioreactor Simulation on BioNet Control System
Bioreactor Simulation on BioNet Control System
Add picture of simulation here
![Page 29: Mammalian Cell Culture Sensors and Models](https://reader038.vdocument.in/reader038/viewer/2022102719/56814c5b550346895db97b2b/html5/thumbnails/29.jpg)
Bioreactor Control System with Concentration Loops
Bioreactor Control System with Concentration Loops
Place bionet main view here
![Page 30: Mammalian Cell Culture Sensors and Models](https://reader038.vdocument.in/reader038/viewer/2022102719/56814c5b550346895db97b2b/html5/thumbnails/30.jpg)
On-line Adaptation of SimulationOn-line Adaptation of Simulation
Actual Plant
Virtual Plant
Online KPI:Yield and Capacity
Inferential Measurements:
Biomass Growth and Production Rates
Adaptation
Key Actual Process VariablesKey Virtual
Process Variables
Model Parameters
Error between virtual and actual process variables
are minimized by correction of model parameters
Actual BatchProfiles
![Page 31: Mammalian Cell Culture Sensors and Models](https://reader038.vdocument.in/reader038/viewer/2022102719/56814c5b550346895db97b2b/html5/thumbnails/31.jpg)
Process Analytical Technology in Process DevelopmentProcess Analytical Technology in Process Development
Dynamic Time Warping allows comparison of matched bioreactors when they progress at different rates.
PCA can weed out unimportant process parameters quickly.
![Page 32: Mammalian Cell Culture Sensors and Models](https://reader038.vdocument.in/reader038/viewer/2022102719/56814c5b550346895db97b2b/html5/thumbnails/32.jpg)
Batches Not AlignedBatches Not Aligned
0
5
10
15
20
25
30
35
40
1 7 13 19 25 31 37 43 49 55 61 67 73 79 85 91 97 103 109 115
![Page 33: Mammalian Cell Culture Sensors and Models](https://reader038.vdocument.in/reader038/viewer/2022102719/56814c5b550346895db97b2b/html5/thumbnails/33.jpg)
Batches Aligned with DTWBatches Aligned with DTW
0
5
10
15
20
25
30
35
40
1 7 13 19 25 31 37 43 49 55 61 67 73 79 85 91 97 103 109 115
![Page 34: Mammalian Cell Culture Sensors and Models](https://reader038.vdocument.in/reader038/viewer/2022102719/56814c5b550346895db97b2b/html5/thumbnails/34.jpg)
PAT Online in Process DevelopmentPAT Online in Process Development Media comparisons Tech Transfers
![Page 35: Mammalian Cell Culture Sensors and Models](https://reader038.vdocument.in/reader038/viewer/2022102719/56814c5b550346895db97b2b/html5/thumbnails/35.jpg)
ReferencesReferences 1. Kleman G.L.,Chalmers J. J., Luli G W, Strohl W R, A Predictive and
Feedback Control Algorithm Maintains a Constant Glucose Concentration in Fed-Batch Fermentations, APPLIED AND ENVIRONMENTAL MICROBIOLOGY, Apr. 1991, p. 910-917
2. Luan Y T, Mutharasan R, Magee W E, Effect of various Glucose/Glutamine Ratios on Hybridoma Growth, Viability and Monoclonal Antibody Formation, Biotechnology Letters Vol 9 No 8 535-538 (1987)
3. McMillan G, Benton T, Zhang Y, Boudreau M, PAT Tools for Accelerated Process Development and Improvement, BioProcess International Supplement MARCH 2008.
4. Boudreau M A, McMillan G K, New Directions in bioprocess Modeling and Control. ISA. Research Triangle Park, NC 2006.
5. Lee J M, Yoo C K, Lee I B, Enhanced process monitoring of fed-batch penicillin cultivation using time-varying and multivariate statistical analysis. Journal of Biotechnology, 110 (2004) 119-136.
6. Cinar A, Parulekar S J, Ündey C, Birol G, Batch Fermentation Modeling, Monitoring, and Control. Marcel Dekker, Inc. New York, NY 2003.
![Page 36: Mammalian Cell Culture Sensors and Models](https://reader038.vdocument.in/reader038/viewer/2022102719/56814c5b550346895db97b2b/html5/thumbnails/36.jpg)
About the PresentersAbout the Presenters
Michael Boudreau is a Principal Consultant at Emerson Process Management.
Trish Benton is a Life Sciences Consultant at Broadley-James Corporation.