Download - Manifold System Booklet 070719
’
Manifold Systems
Information and specifications subject to change without notice. For latest product information please refer to www.hotrunners.com or contact Husky
2007.07
1
PRONTO
2007.07
Please confirm all dimensions and nozzle suitability by contacting Husky.
Husky PRONTO Configurable Manifold Systems
Pronto manifold systems come complete with heated sprue bushing, nozzles, all necessary heaters and thermocouples, associated hardware, and wire clamps. Locating ring and electrical connectors are available upon request.
The resin to be processed should be reviewed with the material compatibility chart on www.hotrunners.com. This will determine if the application being considered is suitable for the Pronto manifold and nozzle/gating combination. The appropriate melt channel sizes will be selected by Husky based on the resin and part information provided.
Husky’s Pronto manifolds are a line of configurable manifold systems which have all the features of our fully custom systems minus plates and are offered at lower cost with faster deliveries. Pronto manifold systems provide far greater flexibility than off-the-shelf or pre-engineered manifold systems. Key features include:
• 2, 4, and 8 Drop configurations
• Infinitely flexible nozzle spacing within upper and lower limits
• Three nozzle sizes (Ultra 500, Ultra 750, and Ultra 1000)
• Sixteen different gating styles including valve gate and thermal gate options
• Every application is reviewed and channel sizes are optimized for the application
• Suitable for a wide range of resins including engineering and filled resins
• Used in a broad variety of markets including housewares, closures, electronics, automotive, medical and more
• Lower cost than custom systems
• Faster delivery than custom systems
This brochure provides information needed to do a preliminary layout of a mold using a Pronto manifold system. For information about Pronto complete hot runner systems, including plate drawings and standard feature locations please visit our web site www.hotrunners.com.
22007.07
PRONTO
Please confirm all dimensions and nozzle suitability by contacting Husky.
PRONTO Manifold System SelectionTo configure Pronto Manifold Systems follow the three simple steps below.
1 Determine the nozzle pitch required for the mold design and ensure that it is within the allowable range for the desired size of plates
2 Select the nozzle size and gating method best suited for your application
3 Select the desired nozzle length based on L -dimension range available for the selected gating style
For example, with an Ultra 750 4-L type manifold with a pitch of 72.35 mm and 221.80mm using valve gated VG tips and 44.45 mm L -dimension, order:MS7504L072.35/221.80M-VG044.45
NOTE: Metric orders will receive metric hardware
For example with an Ultra 750 4-L type manifold with a pitch of 2.125" and 3.875" using thermal gated HT tips and 2.375" L -dimension order:MS7504L1.125/3.875I-HT2.375
NOTE: Imperial orders will receive imperial hardware
PRONTO 1 Drop I-Type Manifold (U1000 Only)
4L072.35/221.80MMS750 VG 044.45Always "M" for metricY-dimension (for 4H/4L-Types only center of manifold to outer drop in mm, two decimals)
X-dimension (center of manifold to outer drop in mm, two decimals)
A, B, H, T, N or L Type manifoldNumber of drops
Gate style L- dimension (in mm, two decimals)
Nozzle size
4L 2.125 / 3.875 IMS750 HT 2.375
Always "I" for Imperial
Y-dimension (for 4H/4L-Types only center of manifold to outer drop in inches, three decimals)
X-dimension (center of manifold to outer drop in inches, three decimals)
A, B, H or L Type manifoldNumber of drops
Gate style L- dimension (in inches, three decimals)
Nozzle size
3
PRONTO
2007.07
Please confirm all dimensions and nozzle suitability by contacting Husky.
PRONTO 2 Drop A-Type Manifolds
PRONTO 2 Drop T-Type Manifold
Nozzle Minimum Pitch (X) Maximum Pitch (X) Number ofT/C’s
Electrical Zones
1000 HT/TS 55mm (2.165")VG/VX 74mm (2.913") 695mm (27.362")
1 T/C Mounted Through Mani-
fold Plate4-5
Nozzle Minimum Pitch (X) Maximum Pitch (X) Number ofT/C’s
Electrical Zones
500 HT/TS 60mm (2.363")VG/VX 70mm (2.756") 366mm (14.409")
1 T/C Mounted Through Mani-
fold Plate4750
1000 HT/VG 55mm (2.165")VG/VX 74mm (2.913")
HT/VG 362mm (14.252")VG/VX 362mm (14.252")
1 T/C Mounted Through Mani-
fold Plate4
Nozzle Minimum Pitch (X1/X2) Maximum Pitch (X1/X2) Number ofT/C’s
Electrical Zones
1000 HT/TS 53mm (2.087")VG/VX 53mm (2.087")
HT/TS 362mm (14.252")VG/VX 362mm (14.252") 1 T/C Mounted
Through Mani-fold Plate
4Minimum Pitch (Y) Maximum Pitch (Y)
1000 HT/TS 53mm (2.087")VG/VX 53mm (2.087")
HT/TS 200mm (7.874")VG/VX 200mm (7.874")
X
X
Y
X2
X1
42007.07
PRONTO
Please confirm all dimensions and nozzle suitability by contacting Husky.
PRONTO 2 Drop T-Type Manifold (Type I)
NOTE: These values are absolute. However, these values cannot be combined otherwise interference will result(i.e. X=25.0 and Y=25.4 is incompatible). To verify that your pitch is acceptable, refer to the table below and solvefor X & Y using the following calculation:U500VG / U750VG / U750HTX + 1.47Y - 83.7 >= 0U500HTX + 1.47Y - 65.3 >= 0If X and Y both satisfy the equation, then the pitch and sprue offset values can be incorporated into Pronto 2T.
PRONTO 2 Drop T-Type Manifold (Type II)
NOTE: These values are absolute. However, these values cannot be combined otherwise interference will result(i.e. X=25.0 and Y=25.4 is incompatible). To verify that your pitch is acceptable, refer to the table below and solvefor X & Y using the following calculation:U500VG / U750VG / U750HTX + 1.47Y - 83.7 >= 0U500HTX + 1.47Y - 65.3 >= 0If X and Y both satisfy the equation, then the pitch and sprue offset values can be incorporated into Pronto 2T.
Nozzle Minimum Pitch (X1/X2) Maximum Pitch (X1/X2) Number ofT/C’s
Electrical Zones
500/750
HT 500 12.7mm (0.500")HT/TS 750 22.5mm
(0.886")VG 500/750 25.0mm
(0.984")
HT 500 350.0mm (13.780")HT/TS 750 350.0mm (13.780")VG 500/750 350.0mm (13.780")
1 or T/C Mounted
Through Mani-fold Plate
4 or 5Minimum Pitch (Y) Maximum Pitch (Y)
500/750
HT 500 25.4mm (1.000")HT/TS 750 25.4mm
(1.000")VG 500/750 25.4mm
(1.000")
HT 500 200.0mm (7.874")HT/TS 750 200.0mm (7.874")VG 500/750 200.0mm (7.874")
Nozzle Minimum Pitch (X1/X2) Maximum Pitch (X1/X2) Number ofT/C’s
Electrical Zones
500/750HT 500 12.7mm (0.500")
HT/TS 750 22.5mm (0.886")VG 500/750 25.0mm (0.984")
HT 500 350.0mm (13.780")HT/TS 750 350.0mm (13.780")VG 500/750 350.0mm (13.780") 1 or T/C
Mounted Through Mani-
fold Plate
4 or 5Minimum Pitch (Y) Maximum Pitch (Y)
500/750HT 500 25.4mm (1.000")
HT/TS 750 25.4mm (1.000")VG 500/750 25.4mm (1.000")
HT 500 200.0mm (7.874")HT/TS 750 200.0mm (7.874")VG 500/750 200.0mm (7.874")
Y
X
X
Y
X
X
5
PRONTO
2007.07
Please confirm all dimensions and nozzle suitability by contacting Husky.
PRONTO 2 Drop T-Type Manifold (Type III)
NOTE: These values are absolute. However, these values cannot be combined otherwise interference will result(i.e. X=25.0 and Y=25.4 is incompatible). To verify that your pitch is acceptable, refer to the table below and solvefor X & Y using the following calculation:U500VG / U750VG / U750HTX + 1.47Y - 83.7 >= 0U500HTX + 1.47Y - 65.3 >= 0If X and Y both satisfy the equation, then the pitch and sprue offset values can be incorporated into Pronto 2T.
PRONTO 4 Drop H-Type Manifolds
PRONTO 4 Drop N-Type Manifolds
PRONTO 4 Drop A-Type Manifolds
Nozzle Minimum Pitch(X1/X2)
Maximum Pitch(X1/X2)
Number of T/C’s
Electrical Zones
HT 500 12.7mm (0.500")HT/TS 750 22.5mm (0.886")VG 500/750 25.0mm (0.984")
HT 500 350.0mm (13.780")HT/TS 750 350.0mm (13.780")VG 500/750 350.0mm (13.780") 1 or T/C
Mounted Through Mani-
fold Plate
4 or 5Minimum Pitch (Y) Maximum Pitch (Y)HT 500 25.4mm (1.000")
HT/TS 750 25.4mm (1.000")VG 500/750 25.4mm (1.000")
HT 500 200.0mm (7.874")HT/TS 750 200.0mm (7.874")VG 500/750 200.0mm (7.874")
Nozzle Minimum Pitch (X) Maximum Pitch (X) Number ofT/C’s
Electrical Zones
500/750 50mm (1.969") 211mm (8.307") 1 or 2 T/C Mounted
Through Mani-fold/Backing
Plate (If Req’d)
6 or 71000 53mm (2.087") 362mm (14.252")
Minimum Pitch (Y) Maximum Pitch (Y)500/750 50mm (1.969") 331mm (13.031")
1000 53mm (2.087") 200mm (7.874")
Nozzle Min Pitch (X1/X2/X3/X4) Max Pitch (X1X2/X3/X4) Number ofT/C’s
Electrical Zones
1000 53mm (2.087") 362mm (14.252") 1 or 2 T/C’s Mounted
Through Mani-fold/Backing
Plate (If Req’d)
6 or 7Min Pitch (Y1/Y2) Max Pitch (Y1/Y2)
1000 53mm (2.087") 200mm (7.874")
Y
X
X
X
Y
X
Y1
X1 X2
X3 X4
Y2
62007.07
PRONTO
Please confirm all dimensions and nozzle suitability by contacting Husky.
PRONTO 4 Drop L-Type Manifolds
NOTE: For HT/TS Y-dimension must be 45mm (1.772") greater than X-dimensionNOTE: For VG/VX Y-dimension must be 57mm (2.244") greater than X-dimension
PRONTO 8 Drop H-Type Manifolds
Nozzle Minimum Pitch (X) Maximum Pitch (X) Number of T/C’s
Electrical Zones
500/750 HT/TS 60mm (2.363")VG/VX 70mm (2.756")
HT/TS 316mm (12.441")VG/VX 304mm (11.969") 1 T/C Mounted
ThroughManifold Plate
6Minimum Pitch (Y) Maximum Pitch (Y)
500/750 HT/TS 105mm (4.134")VG/VX 127mm (5.000") 361mm (14.212")
Nozzle Min X Max X Min Y1 Max Y1 Min Y2 Max Y2 Number ofT/C’s
Electrical Zones
HT 500 73mm (0.708")
211mm (8.307")
61.3mm (1.752")
Y2-62mm (1.000")
Y1+62mm (1.000")
331mm (13.031")
2 T/C Mounted Through Man
Plate2 T/C Mounted Through Back Plate (when
required)
11 or 13HT 750 73mm (0.886")
211mm (8.307")
61.3mm (1.693")
Y2-62mm (1.771")
Y1+62mm (1.771")
331mm (13.031")
VG 500/750 73mm (0.984")
211mm (8.307")
61.3mm (2.165")
Y2-62mm (1.968")
Y1+62mm (1.968")
331mm (13.031")
Y
X
X
Y2
Y1
7
PRONTO
2007.07
1 Drop
Please confirm all dimensions and nozzle suitability by contacting Husky.
PRONTO 1 Drop I-Type Manifolds (Ultra 1000 Only)
Minimum Pitch (X) Maximum Pitch (X) Number of T/C’s Electrical Zones
HT/TS 55mm (2.165")
VG/VX 74mm (2.913")
695mm (27.362") 1 T/C Mounted Through Manifold Plate 3
0,00
0 [.0
000]
RAD 27,5 [1.08]
RAD 35,0[1.38]
X X +
29,
00 [1
.142
]
X +
45,
0 [1
.77]
0,000 [.0000]
28,0 [1.10]
40,0 [1.57]
35,0
[1.3
8]
35,0
[1.3
8]
40,0 [1.57]
113,
0 [4
.45]
R 27,0 [1.06](4)
X +
28,
0 [1
.10]
29,0 [1.14]28,0 [1.10]
X +
15,
2 [0
.60]
15,2 [0.60]
View From Injection Side Plate features are noted on plan view and correspond to features in section view below.
75.0
[2.9
5]
79.0
[3.1
1]
80.8
[3.1
8]
92.6
[3.6
5]
22.2[.88]T/C MF-PLT
22.2[.88]T/C MF-PLT THRU HOLE FOR X> 87 mm
BK-PLT
60.0
0[2
.36]40
.0[1
.57]
70.00[2.76]
*C
3.0
MIN
[.12]
M6 -20 1/4
(2)
30.0[1.18]
8.000 +0.015[.3150 +.0006]
6.8[.27]
MAX 1.5R[.06]
44.01 +0.03[1.733 +.001]
R 1.5 [.06] MAX
MF-PLT
*B*B
60.01 +0.03 [2.36 +.0001]
42.0 [1.66]
6.8 x 17.0 DP.[ .27 x .67 DP.]
8.03 +0.03 x 15.0 DP.[ .32 +.0001 x .59 DP.]
12.5
[0.4
9]
68.00[2.68]
RAD 3.0[.12]
26.8
[1.0
6]
60.0
0[2
.36]
For H
T / T
SFo
r HT
/ TS
M16 [5/8-11 UNC](3 Bolts per drop
recommeded)
For VG / VX
T/C : ThermocoupleBK - PLT : Manifold Backing PlateMF - PLT : Manifold PlateX : Pitch X ValueY : Pitch Y ValueR, RAD : RadiusC : Center Insulator Bore Depth*B : Nozzle Bore Depth**Refer to calculator on www.hotrunners.com
82007.07
PRONTO 2 Drop
Please confirm all dimensions and nozzle suitability by contacting Husky.
PRONTO 2 Drop A-Type Manifolds (Ultra 1000)
Minimum Pitch (X) Maximum Pitch (X) Number of T/C’s Electrical Zones
HT/TS 55mm (2.165")
VG/VX 74mm (2.913")
HT/TS 362mm (14.252")
VG/VX 362mm (14.252")
1 T/C Mounted Through Manifold Plate 4
0,00
0 [.0
000]
RAD 27,5[1.08]
RAD 35,0[1.38]
RAD 5,0 [.20](2)
XX +
41,
00 [1
.614
]
X +
25,
0 [.9
8]
0,000 [0.0000]
60,0 [2.36]
28,0 [1.10]
28,0 [1.10]
40,0 [1.58]
35,0
[1.3
8]
40,0 [1.58]
X +
45,
0 [1
.77]32
,0 [1
.26]
32,0
[1.2
6]
35,0
[1.3
8]
100,0 [3.94]
RAD 27,0 (5)[1.06]View From
Injection SidePlate features are noted on plan view and correspond to features in section view below.
X - 5
2,2
[X -
2 .0
6]IF
X<1
00,0
[3.9
4]T/
C IS
SID
E M
OU
NTE
D
75.0
[2.9
5]
79.0
[3.1
1]
80.8
[3.1
8]
92.6
[3.6
5]
22.2[.88]T/C MF-PLT
22.2[.88]T/C MF-PLT THRU HOLE FOR X> 87 mm
BK-PLT
60.0
0[2
.36]40
.0[1
.57]
70.00[2.76]
*C
3.0
MIN
[.12]
M6 -20 1/4
(2)
30.0[1.18]
8.000 +0.015[.3150 +.0006]
6.8[.27]
MAX 1.5R[.06]
44.01 +0.03[1.733 +.001]
R 1.5 [.06] MAX
MF-PLT
*B*B
60.01 +0.03 [2.36 +.0001]
42.0 [1.66]
6.8 x 17.0 DP.[ .27 x .67 DP.]
8.03 +0.03 x 15.0 DP.[ .32 +.0001 x .59 DP.]
12.5
[0.4
9]
68.00[2.68]
RAD 3.0[.12]
26.8
[1.0
6]
60.0
0[2
.36]
For H
T / T
SFo
r HT
/ TS
M16 [5/8-11 UNC](4 Bolts per drop
recommended)
For VG / VX
T/C : ThermocoupleBK - PLT : Manifold Backing PlateMF - PLT : Manifold PlateX : Pitch X ValueY : Pitch Y ValueR, RAD : RadiusC : Center Insulator Bore Depth*B : Nozzle Bore Depth**Refer to calculator on www.hotrunners.com
9
PRONTO
2007.07
2 Drop
Please confirm all dimensions and nozzle suitability by contacting Husky.
PRONTO 2 Drop A-Type Manifolds (Ultra 750)
Minimum Pitch (X) Maximum Pitch (X) Number of T/C’s Electrical Zones
HT/TS 60mm (2.363")
VG/VX 70mm (2.756")
366mm (14.409") 1 T/C Mounted Through Manifold Plate 4
View From Injection Side
T/C for X ≤ 87mm (3.452")
Plate features are noted on plan view and correspond to features in section view below.
T/C for X > 87mm (3.452")
Manifold Heater#1A (Clamp)#1B (Injection)
Recommeded drop bolt circle
TTHRU HOLE FOR
X>87 mm
MIN
MAX
MAX
M16 [5/8-11 UNC](3 Bolts per drop
recommeded)
For H
T / T
SFo
r VG
/VX
For V
G /V
XFo
r HT
/ TS
For V
G /V
X
For H
T / T
S
T/C : ThermocoupleBK - PLT : Manifold Backing PlateMF - PLT : Manifold PlateX : Pitch X ValueY : Pitch Y ValueR, RAD : RadiusC : Center Insulator Bore Depth*B : Nozzle Bore Depth**Refer to calculator onwww.hotrunners.com
Contact Husky to verfiy T/C thru hole location.Plate features are noted on plan view and correspond to features in section view below.
102007.07
PRONTO 2 Drop
Please confirm all dimensions and nozzle suitability by contacting Husky.
PRONTO 2 Drop A-Type Manifolds (Ultra 500)
Minimum Pitch (X) Maximum Pitch (X) Number of T/C’s Electrical Zones
HT/TS 60mm (2.363")
VG/VX 70mm (2.756")
366mm (14.409") 1 T/C Mounted Through Manifold Plate 4
View From Injection Side
T/C for X ≤ 87mm (3.452")
Plate features are noted on plan view and correspond to features in section view below.
T/C for X > 87mm (3.452")
Manifold Heater#1A (Clamp)#1B (Injection)
Recommeded drop bolt circle
MAX
MIN
THRU HOLEFOR X > 87 mm
M12 [1/2-13 UNC](3 Bolts per drop
recommeded)
For H
T / T
SFo
r VG
/VX
For V
G /V
XFo
r HT
/ TS
For V
G /V
X
Sharp
T/C : ThermocoupleBK - PLT : Manifold Backing PlateMF - PLT : Manifold PlateX : Pitch X ValueY : Pitch Y ValueR, RAD : RadiusC : Center Insulator Bore Depth*B : Nozzle Bore Depth**Refer to calculator onwww.hotrunners.com
Contact Husky to verfiy T/C thru hole location.Plate features are noted on plan view and correspond to features in section view below.
11
PRONTO
2007.07
2 Drop
Please confirm all dimensions and nozzle suitability by contacting Husky.
PRONTO 2 Drop T-Type Manifold Type I (Ultra 1000)
Minimum Pitch (X) Maximum Pitch (X) Number of T/C’s Electrical Zones
53mm (2.087") 362mm (14.252") 1 or 2 T/C Mounted Through Manifold
Plate4 or 5Minimum Pitch (Y) Maximum Pitch (Y)
53mm (2.087") 200mm (7.874")
View From Injection Side
Contact Huskyfor T/C Location
75.0
[2.9
5]
79.0
[3.1
1]
80.8
[3.1
8]
92.6
[3.6
5]
22.2[.88]T/C MF-PLT
22.2[.88]T/C MF-PLT THRU HOLE FOR X> 87 mm
BK-PLT
60.0
0[2
.36]40
.0[1
.57]
70.00[2.76]
*C
3.0
MIN
[.12]
M6 -20 1/4
(2)
30.0[1.18]
8.000 +0.015[.3150 +.0006]
6.8[.27]
MAX 1.5R[.06]
44.01 +0.03[1.733 +.001]
R 1.5 [.06] MAX
MF-PLT
*B*B
60.01 +0.03 [2.36 +.0001]
42.0 [1.66]
6.8 x 17.0 DP.[ .27 x .67 DP.]
8.03 +0.03 x 15.0 DP.[ .32 +.0001 x .59 DP.]
12.5
[0.4
9]
68.00[2.68]
RAD 3.0[.12]
26.8
[1.0
6]
60.0
0[2
.36]
For H
T / T
SFo
r HT
/ TS
M16 [5/8-11 UNC](3 Bolts per drop
recommeded)
For VG / VX
T/C : ThermocoupleBK - PLT : Manifold Backing PlateMF - PLT : Manifold PlateX : Pitch X ValueY : Pitch Y ValueR, RAD : RadiusC : Center Insulator Bore Depth*B : Nozzle Bore Depth**Refer to calculator onwww.hotrunners.com
Contact Husky to verfiy T/C thru hole location.Plate features are noted on plan view and correspond to features in section view below.
X +
41,
00
[1.6
14]
X +
21,
5 [.8
5]
0,00
0 [.0
000]
Y + 130,0 [5.12]
Y
Y + 39,32 [1.548]
51,0 [2.01]
14,0 [0.55]
0,000 [.0000]
30,0 [1.18]
41,0 [1.61]
47,0 [1.85]
24,0
[0.9
5]
30,0
[1.1
8]
X61,0
[2.4
0]
X +
28,
0 [1
.10]
24,0
[0.9
5]
31.4
5 [1
.238
]
R 27,0 (6)[1.06]
R 10,0 (2)[0.39]
RAD 27,5 [1.08]
RAD 35,0[1.38]
122007.07
PRONTO 2 Drop
Please confirm all dimensions and nozzle suitability by contacting Husky.
PRONTO 2 Drop T-Type Manifold Type I (Ultra 750)
Minimum Pitch (X1/X2) Maximum Pitch (X1/X2) Number of T/C’s
Electrical Zones
HT 500 12.7mm (0.500")HT/TS 750 22.5mm (0.886")VG 500/750 25.0mm (0.984")
HT 500 350.0mm (13.780")HT/TS 750 350.0mm (13.780")VG 500/750 350.0mm (13.780")
1 or 2 T/C Mounted Through Manifold
Plate
4 or 5Minimum Pitch (Y) Maximum Pitch (Y)HT 500 25.4mm (1.000")
HT/TS 750 25.4mm (1.000")VG 500/750 25.4mm (1.000")
HT 500 200.0mm (7.874")HT/TS 750 200.0mm (7.874")VG 500/750 200.0mm (7.874")
Y + 55,0 [+ 2.165]Y + 38,0 [+ 1.496]
Y + 33,72 [+ 1.328]Y + 25,5 [+ 1.004]
Y + 6,0 [+ 0.236]Y
Y - 38,0 [- 1.496]Y - 48,0 [- 1.890]
- 1,0 [- 0.04]0,000 [0.0000]
- 31,65 [- 1.246]- 33,0 [- 1.30]
RAD 27,0 [1.06] (8)
RAD 15,0 [0.59]RAD 5,0 [0.20] (2)
-100
,0 [3
.94]
- 56,
0 [-
2.20
]
- 24,
00 [-
0.9
45]
0,00
0 [0
.000
]
RAD 22,0 [0.87] (2)
61,1
[2.4
1] (2
)
26,0
00 [1
.023
6]
66,0
[2.6
0]
XX +
15,
0 [0
.591
]
R 55,0 [2.17]
22,6
5 [0
.892
]
Y - 6,0 [- 0.236]
24,0
[0.9
4]
Y + 23,0 [+ 0.906]
Min > 10,0 [0.394]
View From Injection Side
Recommeded drop bolt circle
TOP
OPERATOR
TTHRU HOLE FOR
X>87 mm
MIN
MAX
MAX
M16 [5/8-11 UNC](3 Bolts per drop
recommeded)
For H
T / T
SFo
r VG
/VX
For V
G /V
XFo
r HT
/ TS
For V
G /V
X
For H
T / T
S
T/C : ThermocoupleBK - PLT : Manifold Backing PlateMF - PLT : Manifold PlateX : Pitch X ValueY : Pitch Y ValueR, RAD : RadiusC : Center Insulator Bore Depth*B : Nozzle Bore Depth**Refer to calculator onwww.hotrunners.com
Contact Husky to verify T/C thru hole location.Plate features are noted on plan view and correspond to features in section view below.
13
PRONTO
2007.07
2 Drop
Please confirm all dimensions and nozzle suitability by contacting Husky.
PRONTO 2 Drop T-Type Manifold Type I (Ultra 500)
Minimum Pitch (X1/X2) Maximum Pitch (X1/X2) Number of T/C’s
Electrical Zones
HT 500 12.7mm (0.500")HT/TS 750 22.5mm (0.886")VG 500/750 25.0mm (0.984")
HT 500 350.0mm (13.780")HT/TS 750 350.0mm (13.780")VG 500/750 350.0mm (13.780")
1 or 2 T/C Mounted Through Manifold
Plate
4 or 5Minimum Pitch (Y) Maximum Pitch (Y)HT 500 25.4mm (1.000")
HT/TS 750 25.4mm (1.000")VG 500/750 25.4mm (1.000")
HT 500 200.0mm (7.874")HT/TS 750 200.0mm (7.874")VG 500/750 200.0mm (7.874")
Y + 55,0 [+ 2.165]Y + 38,0 [+ 1.496]
Y + 33,72 [+ 1.328]
Y + 6,0 [+ 0.236]Y
Y - 38,0 [- 1.496]Y - 48,0 [- 1.890]
- 1,0 [- 0.04]0,000 [0.0000]
- 31,65 [- 1.246]- 33,0 [- 1.30]
RAD 27,0 [1.06] (8)
RAD 15,0 [0.59]RAD 5,0 [0.20] (2)
-100
,0 [3
.94]
- 56,
0 [-
2.20
]
- 24,
00 [-
0.9
45]
0,00
0 [0
.000
]
RAD 22,0 [0.87] (2)
61,1
[2.4
1] (2
)
26,0
00 [1
.023
6]
66,0
[2.6
0]
XX +
15,
0 [0
.591
]
R 55,0 [2.17]
22,6
5 [0
.892
]
Y - 6,0 [- 0.236]
24,0
[0.9
4]
Y + 23,0 [+ 0.906]
Min > 10,0 [0.394]
Y + 18,0 [+ 0.17] (2)
View From Injection Side
Recommeded drop bolt circle
OPERATOR
TOP
MAX
MIN
THRU HOLEFOR X > 87 mm
M12 [1/2-13 UNC](3 Bolts per drop
recommeded)
For H
T / T
SFo
r VG
/VX
For V
G /V
XFo
r HT
/ TS
For V
G /V
X
Sharp
T/C : ThermocoupleBK - PLT : Manifold Backing PlateMF - PLT : Manifold PlateX : Pitch X ValueY : Pitch Y ValueR, RAD : RadiusC : Center Insulator Bore Depth*B : Nozzle Bore Depth**Refer to calculatoron www.hotrunners.com
Contact Husky to verfiy T/C thru hole location.Plate features are noted on plan view and correspond to features in section view below.
142007.07
PRONTO 2 Drop
Please confirm all dimensions and nozzle suitability by contacting Husky.
PRONTO 2 Drop T-Type Manifold Type II (Ultra 750)
Minimum Pitch (X1/X2) Maximum Pitch (X1/X2) Number of T/C’s
Electrical Zones
HT 500 12.7mm (0.500")HT/TS 750 22.5mm (0.886")VG 500/750 25.0mm (0.984")
HT 500 350.0mm (13.780")HT/TS 750 350.0mm (13.780")
VG 500/750 350.0mm (13.780")
1 or 2 T/C Mounted Through Manifold
Plate
4 or 5Minimum Pitch (Y) Maximum Pitch (Y)HT 500 25.4mm (1.000")
HT/TS 750 25.4mm (1.000")VG 500/750 25.4mm (1.000")
HT 500 200.0mm (7.874")HT/TS 750 200.0mm (7.874")VG 500/750 200.0mm (7.874")
Y - 55,0 [- 2.165]Y - 38,0 [- 1.496]
Y - 33,72 [- 1.328]Y - 25,5 [- 1.004]
Y - 6,0 [- 0.236]Y
Y + 38,0 [+ 1.496]Y + 48,0 [+ 1.890]
+ 1,0 [+ 0.04]0,000 [0.0000]
+ 31,65 [+ 1.246]+ 33,0 [+ 1.30]
RAD 27,0 [1.06] (8)
RAD 15,0 [0.59]RAD 5,0 [0.20] (2)
-100
,0 [-
3.9
4]
- 56,
0 [-
2.20
]
- 24,
00 [-
0.9
45]
0,00
0 [0
.000
]RAD 22,0 [0.87] (2)
61,1
[2.4
1] (2
)
26,0
00 [1
.023
6]
66,0
[2.6
0]X
X +
15,0
[0.5
91]
R 55,0 [2.17]
22,6
5 [0
.892
]
Y + 6,0 [+ 0.236]
24,0
[0.9
4]
Y - 23,0 [- 0.906]
Min > 10,0 [0.394]
View From Injection Side
Recommeded drop bolt circle
TOP
OPERATOR
TTHRU HOLE FOR
X>87 mm
MIN
MAX
MAX
M16 [5/8-11 UNC](3 Bolts per drop
recommeded)
For H
T / T
SFo
r VG
/VX
For V
G /V
XFo
r HT
/ TS
For V
G /V
X
For H
T / T
S
T/C : ThermocoupleBK - PLT : Manifold Backing PlateMF - PLT : Manifold PlateX : Pitch X ValueY : Pitch Y ValueR, RAD : RadiusC : Center Insulator Bore Depth*B : Nozzle Bore Depth**Refer to calculatoron www.hotrunners.com
Contact Husky to verfiy T/C thru hole location.Plate features are noted on plan view and correspond to features in section view below.
15
PRONTO
2007.07
2 Drop
Please confirm all dimensions and nozzle suitability by contacting Husky.
PRONTO 2 Drop T-Type Manifold Type II (Ultra 500)
Minimum Pitch (X1/X2) Maximum Pitch (X1/X2) Number of T/C’s
Electrical Zones
HT 500 12.7mm (0.500")HT/TS 750 22.5mm (0.886")VG 500/750 25.0mm (0.984")
HT 500 350.0mm (13.780")HT/TS 750 350.0mm (13.780")VG 500/750 350.0mm (13.780")
1 or 2 T/C Mounted Through Manifold
Plate
4 or 5Minimum Pitch (Y) Maximum Pitch (Y)HT 500 25.4mm (1.000")
HT/TS 750 25.4mm (1.000")VG 500/750 25.4mm (1.000")
HT 500 200.0mm (7.874")HT/TS 750 200.0mm (7.874")VG 500/750 200.0mm (7.874")
Y - 55,0 [- 2.165]Y - 38,0 [- 1.496]
Y - 33,72 [- 1.328]
Y - 6,0 [- 0.236]Y
Y + 38,0 [+ 1.496]Y + 48,0 [+ 1.890]
+ 1,0 [+ 0.04]0,000 [0.0000]
+ 31,65 [+ 1.246]+ 33,0 [+ 1.30]
RAD 27,0 [1.06] (8)
RAD 15,0 [0.59]RAD 5,0 [0.20] (2)
-100
,0 [-
3.9
4]
- 56,
0 [-
2.20
]
- 24,
00 [-
0.9
45]
0,00
0 [0
.000
]
RAD 22,0 [0.87] (2)
61,1
[2.4
1] (2
)
26,0
00 [1
.023
6]
66,0
[2.6
0]X
X +
15,0
[0.5
91]
R 55,0 [2.17]
22,6
5 [0
.892
]
Y + 6,0 [+ 0.236]
24,0
[0.9
4]
Y - 23,0 [- 0.906]
Min > 10,0 [0.394]
Y + 18,0 [+ 0.17]
View From Injection Side
Recommeded drop bolt circle
TOP
OPERATOR
MAX
MIN
THRU HOLEFOR X > 87 mm
M12 [1/2-13 UNC](3 Bolts per drop
recommeded)
For H
T / T
SFo
r VG
/VX
For V
G /V
X
Sharp
T/C : ThermocoupleBK - PLT : Manifold Backing PlateMF - PLT : Manifold PlateX : Pitch X ValueY : Pitch Y ValueR, RAD : RadiusC : Center Insulator Bore Depth*B : Nozzle Bore Depth**Refer to calculator onwww.hotrunners.com
Plate features are noted on plan view and correspond to features in section view below.
162007.07
PRONTO 2 Drop
Please confirm all dimensions and nozzle suitability by contacting Husky.
PRONTO 2 Drop T-Type Manifold Type III (Ultra 750)
Minimum Pitch (X1/X2) Maximum Pitch (X1/X2) Number of T/C’s
Electrical Zones
HT 500 12.7mm (0.500")HT/TS 750 22.5mm (0.886")VG 500/750 25.0mm (0.984")
HT 500 350.0mm (13.780")HT/TS 750 350.0mm (13.780")VG 500/750 350.0mm (13.780")
1 or 2 T/C Mounted Through Manifold
Plate
4 or 5Minimum Pitch (Y) Maximum Pitch (Y)HT 500 25.4mm (1.000")
HT/TS 750 25.4mm (1.000")VG 500/750 25.4mm (1.000")
HT 500 200.0mm (7.874")HT/TS 750 200.0mm (7.874")VG 500/750 200.0mm (7.874")
0,00
0 [0
.000
]RAD 27,0 [1.0630] (7)
0,000 [0.000]
Y - 6,0 [0.24]Y
Y + 6,0 [0.24]
Y - 43,0 [1.69]
-31.65 [-1.246]
Y + 25,50 [1.004]
Y + 38,0 [1.50] (2)Y + 33,72 [1.328]
Y + 59,2 [2.33]
Y + 93,0 [3.66]
- 24,
00 [-
0.9
45] (
2)
22,6
5 [0
.892
]26
,000
[1.0
236]
32,0
[1.2
6] (2
)
53,2
[2.1
0] (2
)61
,0 [2
.40]
(2)
RAD 10,000 [0.3937] (2)
RAD 5,000 [0.1969] (4)
R 55,0 [2.17]
XX +
15,0
[0.5
9]
- 33,0 [-1.30] (2)View From Injection Side
Recommeded drop bolt circle
TOP
OP
ER
ATO
R
TTHRU HOLE FOR
X>87 mm
MIN
MAX
MAX
M16 [5/8-11 UNC](3 Bolts per drop
recommeded)
For V
G /V
X
For V
G /V
XFo
r HT
/ TS
For V
G /V
X
For H
T / T
S
For H
T / T
S
T/C : ThermocoupleBK - PLT : Manifold Backing PlateMF - PLT : Manifold PlateX : Pitch X ValueY : Pitch Y ValueR, RAD : RadiusC : Center Insulator Bore Depth*B : Nozzle Bore Depth**Refer to calculator on www.hotrun-
Plate features are noted on plan view and correspond to features in section view below.
17
PRONTO
2007.07
2 Drop
Please confirm all dimensions and nozzle suitability by contacting Husky.
PRONTO 2 Drop T-Type Manifold Type III (Ultra 500)
Minimum Pitch (X1/X2) Maximum Pitch (X1/X2) Number of T/C’s
Electrical Zones
HT 500 12.7mm (0.500")HT/TS 750 22.5mm (0.886")VG 500/750 25.0mm (0.984")
HT 500 350.0mm (13.780")HT/TS 750 350.0mm (13.780")VG 500/750 350.0mm (13.780")
1 or 2 T/C Mounted Through Manifold
Plate
4 or 5Minimum Pitch (Y) Maximum Pitch (Y)HT 500 25.4mm (1.000")
HT/TS 750 25.4mm (1.000")VG 500/750 25.4mm (1.000")
HT 500 200.0mm (7.874")HT/TS 750 200.0mm (7.874")VG 500/750 200.0mm (7.874")
0,00
0 [0
.000
]
RAD 27,0 [1.0630] (7)
0,000 [0.000]
Y - 6,0 [0.24]Y
Y + 6,0 [0.24]
Y - 43,0 [1.69]
-31.65 [-1.246]
Y + 38,0 [1.50] (2)Y + 33,72 [1.328]
Y + 59,2 [2.33]
Y + 93,0 [3.66]
- 24,
00 [-
0.9
45] (
2)
22,6
5 [0
.892
]26
,000
[1.0
236]
32,0
[1.2
6] (2
)
53,2
[2.1
0] (2
)61
,0 [2
.40]
(2)
RAD 10,000 [0.3937] (2)
RAD 5,000 [0.1969] (4)
R 55,0 [2.17]
X
- 33,0 [-1.30] (2)
Y + 18,0 [+ 0.17]X
+ 15
,0 [0
.59]
View From Injection Side
Recommeded drop bolt circle
TOP
OPE
RA
TOR
MAX
MIN
THRU HOLEFOR X > 87 mm
M12 [1/2-13 UNC](3 Bolts per drop
recommeded)
For H
T / T
SFo
r VG
/VX
For V
G /V
X
Sharp
T/C : ThermocoupleBK - PLT : Manifold Backing PlateMF - PLT : Manifold PlateX : Pitch X ValueY : Pitch Y ValueR, RAD : RadiusC : Center Insulator Bore Depth*B : Nozzle Bore Depth**Refer to calculator onwww.hotrunners.com
Plate features are noted on plan view and correspond to features in section view below.
182007.07
PRONTO 4 Drop
Please confirm all dimensions and nozzle suitability by contacting Husky.
PRONTO 4 Drop H-Type Manifolds (Ultra 1000)
Minimum Pitch (X) Maximum Pitch (X) Number of T/C’s Electrical Zones
53mm (2.087") 362mm (14.252") 1 T/C Mounted thru MF PLT1 T/C Mounted Thru BK
PLT (when required)6 or 7Minimum Pitch (Y) Maximum Pitch (Y)
53mm (2.087") 200mm (7.874")
X +
41,
00 [1
.614
]
X +
21,
5 [.8
5]
0,000 [.0000]
Y2
Y2 + 22,0 [0.87]
Y2 - 13,0 [0.51]
Y2 - 17,7 [0.70]
Y2 - 52,7 [2.07]
Y1 - 52,7 [2.07]
Y1 - 17,7 [0.70]Y1 - 13,0 [0.51]
Y1 + 61,7 [2.43]
Y1 + 100,0 [3.94]
Y1 + 22,0 [0.87]
56,7
[2.2
3]
X 0,00
0 [.0
000]
X +
21,
0 [1
.06]
RAD 35,0 [1.38]
RAD 27,5 [1.08]
RAD 12,7 (6)[1.06]
X +
28,
0 [1
.10]
X +
39,
7 [1
.56]
X +
21,
0 [0
.83]
Contact Huskyfor T/C Location
Y1
RAD 27,0 (6)[1.06]
View From Injection Side
Plate features are noted on plan view and correspond to features in section view below.
75.0
[2.9
5]
79.0
[3.1
1]
80.8
[3.1
8]
92.6
[3.6
5]
22.2[.88]T/C MF-PLT
22.2[.88]T/C MF-PLT THRU HOLE FOR X> 87 mm
BK-PLT
60.0
0[2
.36]40
.0[1
.57]
70.00[2.76]
*C
3.0
MIN
[.12]
M6 -20 1/4
(2)
30.0[1.18]
8.000 +0.015[.3150 +.0006]
6.8[.27]
MAX 1.5R[.06]
44.01 +0.03[1.733 +.001]
R 1.5 [.06] MAX
MF-PLT
*B*B
60.01 +0.03 [2.36 +.0001]
42.0 [1.66]
6.8 x 17.0 DP.[ .27 x .67 DP.]
8.03 +0.03 x 15.0 DP.[ .32 +.0001 x .59 DP.]
12.5
[0.4
9]
68.00[2.68]
RAD 3.0[.12]
26.8
[1.0
6]
60.0
0[2
.36]
For H
T / T
SFo
r HT
/ TS
For V
G /
VX
For V
G /
VXM16 [5/8-11 UNC]
(4 Bolts per droprecommended)
T/C : ThermocoupleBK - PLT : Manifold Backing PlateMF - PLT : Manifold PlateX : Pitch X ValueY : Pitch Y ValueR, RAD : RadiusC : Center Insulator Bore Depth*B : Nozzle Bore Depth**Refer to calculator onwww.hotrunners.com
19
PRONTO
2007.07
4 Drop
Please confirm all dimensions and nozzle suitability by contacting Husky.
PRONTO 4 Drop H-Type Manifolds (Ultra 750)
Minimum Pitch (X) Maximum Pitch (X) Number of T/C’s Electrical Zones
HT/TS 50mm (1.969")VG/VX 50mm (1.969")
HT/TS 211mm (8.307")VG/VX 211mm (8.307")
1 T/C Mounted Through MF PLT1 T/C Mounted
Through BK PLT (when required)
6 or 7Minimum Pitch (Y) Maximum Pitch (Y)HT/TS 50mm (1.969")VG/VX 50mm (1.969") 331mm (13.031")
View From Injection Side
Plate features are noted on plan view and correspond to features in section view below.
Recommeded drop bolt circle
Manifold Heater#1A (Clamp)
#1B (Injection)
TTHRU HOLE FOR
X>87 mm
MIN
MAX
MAX
M16 [5/8-11 UNC](3 Bolts per drop
recommeded)
For V
G /V
X
For V
G /V
XFo
r HT
/ TS
For V
G /V
X
For H
T / T
SFor H
T / T
S
T/C : ThermocoupleBK - PLT : Manifold Backing PlateMF - PLT : Manifold PlateX : Pitch X ValueY : Pitch Y ValueR, RAD : RadiusC : Center Insulator Bore Depth*B : Nozzle Bore Depth**Refer to calculator onwww.hotrunners.com
202007.07
PRONTO 4 Drop
Please confirm all dimensions and nozzle suitability by contacting Husky.
PRONTO 4 Drop H-Type Manifolds (Ultra 500)
Minimum Pitch (X) Maximum Pitch (X) Number of T/C’s Electrical Zones
HT/TS 50mm (1.969")VG/VX 50mm (1.969")
HT/TS 211mm (8.307")VG/VX 211mm (8.307")
1 T/C Mounted Through MF PLT1 T/C Mounted
Through BK PLT (when required)
6 or 7Minimum Pitch (Y) Maximum Pitch (Y)HT/TS 50mm (1.969")VG/VX 50mm (1.969") 331mm (13.031")
View From Injection Side
Plate features are noted on plan view and correspond to features in section view below.
Recommeded drop bolt circle
Manifold Heater#1A (Clamp)
#1B (Injection)
MAX
MIN
THRU HOLEFOR X > 87 mm
M12 [1/2-13 UNC](3 Bolts per drop
recommeded)
For H
T / T
SFo
r VG
/VX
For V
G /V
X
SharpT/C : ThermocoupleBK - PLT : Manifold Backing PlateMF - PLT : Manifold PlateX : Pitch X ValueY : Pitch Y ValueR, RAD : RadiusC : Center Insulator Bore Depth*B : Nozzle Bore Depth**Refer to calculator onwww.hotrunners.com
21
PRONTO
2007.07
4 Drop
Please confirm all dimensions and nozzle suitability by contacting Husky.
PRONTO 4 Drop N-Type Manifolds (Ultra 1000)
Min Pitch (X1,2,3,4) Max Pitch (X1,2,3,4) No. of T/C’s Electrical Zones
53mm (2.087") 362mm (14.252") 1 T/C Mounted thru MF PLT1 T/C Mounted Thru BK
PLT (when required)6 or 7Min Pitch (Y1/Y2) Max Pitch (Y1/Y2)
53mm (2.087") 200mm (7.874")
X1
+ 41
,00
[1.6
14]
X1
+ 21
,5 [.
85]
0,000 [.0000]
Y2
Y2 + 22,0 [0.87]
Y2 - 13,0 [0.51]
Y2 - 17,7 [0.70]
Y2 - 52,7 [2.07]
Y1 - 52,7 [2.07]
Y1 - 17,7 [0.70]Y1 - 13,0 [0.51]
Y1 + 61,7 [2.43]
Y1 + 100,0 [3.94]
Y1 + 22,0 [0.87]
- 56,
7 [2
.23]
X1
X20,00
0 [.0
000]
21,0
[1.0
6]
RAD 35,0 [1.38]
RAD 27,5 [1.08]
RAD 12,7 (6)[1.06]
X1
+ 28
,0 [1
.10]
- 39,
7 [1
.56]
- 21,
0 [0
.83]
Y1
RAD 27,0 (6)[1.06]
X3
X4
View From Injection Side
Plate features are noted on plan view and correspond to features in section view below.
Contact Huskyfor T/C location
75.0
[2.9
5]
79.0
[3.1
1]
80.8
[3.1
8]
92.6
[3.6
5]
22.2[.88]T/C MF-PLT
22.2[.88]T/C MF-PLT THRU HOLE FOR X> 87 mm
BK-PLT
60.0
0[2
.36]40
.0[1
.57]
70.00[2.76]
*C
3.0
MIN
[.12]
M6 -20 1/4
(2)
30.0[1.18]
8.000 +0.015[.3150 +.0006]
6.8[.27]
MAX 1.5R[.06]
44.01 +0.03[1.733 +.001]
R 1.5 [.06] MAX
MF-PLT
*B*B
60.01 +0.03 [2.36 +.0001]
42.0 [1.66]
6.8 x 17.0 DP.[ .27 x .67 DP.]
8.03 +0.03 x 15.0 DP.[ .32 +.0001 x .59 DP.]
12.5
[0.4
9]
68.00[2.68]
RAD 3.0[.12]
26.8
[1.0
6]
60.0
0[2
.36]
For H
T / T
SFo
r HT
/ TS For VG / VXM16 [5/8-11 UNC]
(4 Bolts per droprecommended)
T/C : ThermocoupleBK - PLT : Manifold Backing PlateMF - PLT : Manifold PlateX : Pitch X ValueY : Pitch Y ValueR, RAD : RadiusC : Center Insulator Bore Depth*B : Nozzle Bore Depth**Refer to calculator onwww.hotrunners.com
222007.07
PRONTO 4 Drop
Please confirm all dimensions and nozzle suitability by contacting Husky.
PRONTO 4 Drop L-Type Manifolds (Ultra 750)
Minimum Pitch (X) Maximum Pitch (X) Number of T/C’s Electrical Zones
HT/TS 60mm (2.363")VG/VX 70mm (2.756")
HT/TS 316mm (12.441")VG/VX 304mm (11.969")
1 T/C Mounted Through Manifold Plate 6Minimum Pitch (Y) Maximum Pitch (Y)
HT/TS 105mm (4.134")VG/VX 127mm (5.000") 361mm (14.212")
View FromInjection Side
Plate features are noted on plan view and correspond to features in section view below.
Manifold Heater#1A (Clamp)#1B (Injection)
Manifold T/C#1 and #1S (Clamp)
TTHRU HOLE FOR
X>87 mm
MIN
MAX
MAX
M16 [5/8-11 UNC](3 Bolts per drop
recommeded)Fo
r VG
/VX
For V
G /V
XFo
r HT
/ TS
For V
G /V
X
For H
T / T
S
For H
T / T
S
NOTE: For HT/TS Y-dimension must be 45mm (1.772") greater than X-dimensionNOTE: For VG/VX Y-dimension must be 57mm (2.244") greater than X-dimension
T/C : ThermocoupleBK - PLT : Manifold Backing PlateMF - PLT : Manifold PlateX : Pitch X ValueY : Pitch Y ValueR, RAD : RadiusC : Center Insulator Bore Depth*B : Nozzle Bore Depth**Refer to calculator onwww.hotrunners.com
23
PRONTO
2007.07
4 Drop
Please confirm all dimensions and nozzle suitability by contacting Husky.
PRONTO 4 Drop L-Type Manifolds (Ultra 500)
Minimum Pitch (X) Maximum Pitch (X) Number of T/C’s Electrical Zones
HT/TS 60mm (2.363")VG/VX 70mm (2.756")
HT/TS 316mm (12.441")VG/VX 304mm (11.969")
1 T/C Mounted Through Manifold Plate 6Minimum Pitch (Y) Maximum Pitch (Y)
HT/TS 105mm (4.134")VG/VX 127mm (5.000") 361mm (14.212")
View From Plate features are noted on plan view and correspond to features in section view below.
Manifold Heater#1A (Clamp)#1B (Injection)
Manifold T/C#1 and #1S (Clamp)
MAX
MIN
THRU HOLEFOR X > 87 mm
M12 [1/2-13 UNC](3 Bolts per drop
recommeded)
For H
T / T
SFo
r VG
/VX
For V
G /V
X
Sharp
NOTE: For HT/TS Y-dimension must be 45mm (1.772") greater than X-dimensionNOTE: For VG/VX Y-dimension must be 57mm (2.244") greater than X-dimension
T/C : ThermocoupleBK - PLT : Manifold Backing PlateMF - PLT : Manifold PlateX : Pitch X ValueY : Pitch Y ValueR, RAD : RadiusC : Center Insulator Bore Depth*B : Nozzle Bore Depth**Refer to calculator onwww.hotrunners.com
242007.07
PRONTO 8 Drop
Please confirm all dimensions and nozzle suitability by contacting Husky.
PRONTO 8 Drop H-Type Tight Pitch Manifold (Ultra 750)
Gate Min X Max X Min Y1 Max Y1 Min Y2 Max Y2 Number of T/C’s Electrical Zones
HT >73.0mm(2.87")
211mm(8.307")
>61.3mm(2.41")
Y2-45mm (1.771")
Y1 + 62.0mm(2.41")
331mm (13.031")
2 T/C’s Mounted Through Manifold
Plate2 T/C’s Mounted Through Backing
Plate (when required)
11 or 13
VG >73.0mm(2.87")
211mm (8.307")
>61.3mm(2.41")
Y2-50mm (1.968")
Y1+62.0mm(2.41")
331mm (13.031")
Step 2: Layout plate features using pitch dimension for X value
Step 1: Layout manifold pocket profile using pitch dimension for X value
Step 3:Section view shown above corresponds to feature callouts (Ultra 750) planview.
Y2 +
80,
0 [3
.14]
Y2 +
46,
0 [1
.81]
Y2 +
14,
0 [.5
5]
X
0,000 [.0000]
X + 14,0 [.55]
32,0 [1.26]
-15,0 [-.59]
X + 25,5 [1.00] R 27,0 [1.06] (6)
R 5,0 [.20] (4)
0,00
0 [.0
000]
Y2 Y1*[(Y1
+Y2)
/2]+
15
15,0 [.59]*28,0 [1.10]
*-28,0 [-1.10]
*[(Y1
+Y2)
/2]-1
5
**(Y
1+Y2
/2)
** Y
2
R 27,0 [1.06]
View FromInjection Side
NOTE: USE TIGHT PITCH POCKET PROFILE IF [Y1</=50,0 (1.969")] & [X</=45,0 (1.771")]
Manifold Heater#2A (Injection)#2B (Injection)
Manifold Heater#1A (Clamp)#1B (Clamp)
Contact Huskyfor T/C location
Contact Huskyfor T/C location
*Depending upon pitch values, hold down screw will differ. Contact Husky for specific location, otherwise include both.
**Depending upon pitch values, dowel location will differ. Contact Husky for specific location, otherwise include both.
TOP
TTHRU HOLE FOR
X>87 mm
MIN
MAX
MAX
M16 [5/8-11 UNC](3 Bolts per drop
recommeded)
For V
G /V
X
For V
G /V
XFo
r HT
/ TS
For V
G /V
X
For H
T / T
S
For H
T / T
S
T/C : ThermocoupleBK - PLT : Manifold Backing PlateMF - PLT : Manifold PlateX : Pitch X ValueY : Pitch Y ValueR, RAD : RadiusC : Center Insulator Bore Depth*B : Nozzle Bore Depth**Refer to calculator onwww.hotrunners.com
25
PRONTO
2007.07
8 Drop
Please confirm all dimensions and nozzle suitability by contacting Husky.
PRONTO 8 Drop H-Type Large Pitch Manifold (Ultra 750)
Gate Min X Max X Min Y1 Max Y1 Min Y2 Max Y2 Number of T/C’s Electrical Zones
HT >73.0mm(2.87")
211mm(8.307")
>61.3mm(2.41")
Y2-45mm (1.771")
Y1 + 62.0mm(2.41")
331mm (13.031")
2 T/C’s Mounted Through Manifold
Plate2 T/C’s Mounted Through Backing
Plate (when required)
11 or 13
VG >73.0mm(2.87")
211mm (8.307")
>61.3mm(2.41")
Y2-50mm (1.968")
Y1+62.0mm(2.41")
331mm (13.031")
Step 1: Layout manifold pocket profile using pitch dimension for X value
Step 2: Layout plate features using pitch dimension for X value
Step 3:Section view shown above corresponds to feature callouts (Ultra 750) planview.
Y2 Y1
X
0,000 [.0000]
0,00
0 [.0
000]
X + 9,0 [.35]
37,0 [1.46]54,0 [2.13]
-15,0 [-.59]
X + 25,5 [1.00]
Y2 +
80,
0 [3
.15]
Y2 +
46,
0 [1
.81]
Y2 +
9,0
[.04
]
Y1 -
9,0
[.35]
Y1 -
26,0
[1.0
2]
R 27,0 [1.06] (10)
R 10,0 [.39] (8)
15,0 [.59]
[(Y1+
Y2)/2
]+15
[(Y1+
Y2)/2
]-15
**(Y
1+Y2
/2)
** Y
2
R 27,0 [1.06]
View FromInjection Side
NOTE: USE LARGE PITCH POCKET PROFILE IF [Y1>50,0 (1.969")] & [X>45,0 (1.771")]
Manifold Heater#2A (Injection)#2B (Injection)
Manifold Heater#1A (Clamp)#1B (Clamp)
Contact Huskyfor T/C location
Contact Huskyfor T/C location **Depending upon pitch values, dowel location will differ.
Contact Husky for specific location, otherwise include both.
TOP
TTHRU HOLE FOR
X>87 mm
MIN
MAX
MAX
M16 [5/8-11 UNC](3 Bolts per drop
recommeded)
For V
G /V
X
For V
G /V
XFo
r HT
/ TS
For V
G /V
X
For H
T / T
S
For H
T / T
S
T/C : ThermocoupleBK - PLT : Manifold Backing PlateMF - PLT : Manifold PlateX : Pitch X ValueY : Pitch Y ValueR, RAD : RadiusC : Center Insulator Bore Depth*B : Nozzle Bore Depth**Refer to calculator onwww.hotrunners.com
262007.07
PRONTO 8 Drop
Please confirm all dimensions and nozzle suitability by contacting Husky.
PRONTO 8 Drop H-Type Tight Pitch Manifold (Ultra 500)
Gate Min X Max X Min Y1 Max Y1 Min Y2 Max Y2 Number of T/C’s Electrical Zones
HT >73.0mm(2.87")
211mm(8.307")
>61.3mm(2.41")
Y2-45mm (1.771")
Y1 + 62.0mm(2.41")
331mm (13.031")
2 T/C’s Mounted Through Manifold
Plate2 T/C’s Mounted Through Backing
Plate (when required)
11 or 13VG >73.0mm
(2.87") 211mm (8.307")
>61.3mm(2.41")
Y2-50mm (1.968")
Y1+62.0mm(2.41")
331mm (13.031")
Step 1: Layout manifold pocket profile using pitch dimension for X value
Step 2: Layout plate features using pitch dimension for X value
Step 3:Section view shown above corresponds to feature callouts (Ultra 500) planview.
Y2
+ 8
0,0
[3.1
4]
Y2
+ 4
6,0
[1.8
1]
Y2
+ 1
4,0
[.55]
X
0,000 [.0000]
X + 14,0 [.55]
32,0 [1.26]
-15,0 [-.59]
X + 18,0 [.71] R 27,0 [1.06] (6)
R 5,0 [.20] (4)
0,00
0 [.0
000]
Y2
Y1*[(Y
1+Y
2)/2
]+15
15,0 [.59]*28,0 [1.10]
*-28,0 [-1.10]
*[(Y
1+Y
2)/2
]-15
**(Y
1+Y
2/2)
** Y
2
R 27,0 [1.06]
View FromInjection Side
NOTE: USE TIGHT PITCH POCKET PROFILE IF [Y1</=50,0 (1.969")] & [X</=45,0 (1.771")]
*Depending upon pitch values, hold down screw will differ. Contact Husky for specific location, otherwise include both.
**Depending upon pitch values, dowel location will differ. Contact Husky for specific location, otherwise include both.
Manifold Heater#2A (Injection)#2B (Injection)Manifold Heater
#1A (Clamp)#1B (Clamp)
Contact Huskyfor T/C location
Contact Huskyfor T/C location
TOP
MAX
MIN
THRU HOLEFOR X > 87 mm
M12 [1/2-13 UNC](3 Bolts per drop
recommeded)
For H
T / T
SFo
r VG
/VX
For V
G /V
X
SharpT/C : ThermocoupleBK - PLT : Manifold Backing PlateMF - PLT : Manifold PlateX : Pitch X ValueY : Pitch Y ValueR, RAD : RadiusC : Center Insulator Bore Depth*B : Nozzle Bore Depth**Refer to calculator onwww.hotrunners.com
27
PRONTO
2007.07
8 Drop
Please confirm all dimensions and nozzle suitability by contacting Husky.
PRONTO 8 Drop H-Type Large Pitch Manifold (Ultra 500)
Gate Min X Max X Min Y1 Max Y1 Min Y2 Max Y2 Number of T/C’s Electrical Zones
HT >73.0mm(2.87")
211mm(8.307")
>61.3mm(2.41")
Y2-45mm (1.771")
Y1 + 62.0mm(2.41")
331mm (13.031")
2 T/C’s Mounted Through Manifold
Plate2 T/C’s Mounted Through Backing
Plate (when required)
11 or 13VG >73.0mm
(2.87") 211mm (8.307")
>61.3mm(2.41")
Y2-50mm (1.968")
Y1+62.0mm(2.41")
331mm (13.031")
Step 1: Layout manifold pocket profile using pitch dimension for X value
Step 2: Layout plate features using pitch dimension for X value
Step 3:Section view shown above corresponds to feature callouts (Ultra 750) planview.
Y2 Y1
X
0,000 [.0000]
0,00
0 [.0
000]
X + 9,0 [.35]
37,0 [1.46]54,0 [2.13]
-15,0 [-.59]
X + 18,0 [.71]
Y2 +
80,
0 [3
.15]
Y2 +
46,
0 [1
.81]
Y2 +
9,0
[.04
]
Y1 -
9,0
[.35]
Y1 -
26,0
[1.0
2]
R 27,0 [1.06] (10)
R 10,0 [.39] (8)
15,0 [.59]
[(Y1+
Y2)/2
]+15
[(Y1+
Y2)/2
]-15
**(Y
1+Y2
/2)
** Y
2
R 27,0 [1.06]
View FromInjection Side
NOTE: USE LARGE PITCH POCKET PROFILE IF [Y1>50,0 (1.969")] & [X>45,0 (1.771")]
Manifold Heater#2A (Injection)#2B (Injection)
Manifold Heater#1A (Clamp)#1B (Clamp)
Contact Huskyfor T/C location
Contact Huskyfor T/C location
TOP
**Depending upon pitch values, dowel location will differ. Contact Husky for specific location, otherwise include both.
MAX
MIN
THRU HOLEFOR X > 87 mm
M12 [1/2-13 UNC](3 Bolts per drop
recommeded)
For H
T / T
SFo
r VG
/VX
For V
G /V
X
Sharp T/C : ThermocoupleBK - PLT : Manifold Backing PlateMF - PLT : Manifold PlateX : Pitch X ValueY : Pitch Y ValueR, RAD : RadiusC : Center Insulator Bore Depth*B : Nozzle Bore Depth**Refer to calculator onwww.hotrunners.com