Page 1: MV pole, rod and rope insulation tester

Pole, Rod and Rope Insulation TesterTT7415

Page 2: MV pole, rod and rope insulation tester

Pole, Rod and Rope Insulation TesterTT7415

Caliber switch

only one or some green leds must light up

Integrated self test with the tube test

Page 3: MV pole, rod and rope insulation tester

■ Functions of the MV Pole, Rod and Rope Insulation Tester

The TT7415 insulation tester can be used to check alternatively whether the dielectric properties of a material are sufficient and consistent and to locate potential insulation faults.

It has the ability to find internal faults, and is therefore not limited to identifying surface faults.

Based on hi-frequency currents properties, it provides in-depth testing, making this a unique device, especially for ropes.

for testing insulating rods for testing insulating sticks and tubes for testing insulating Ropes

This is a site and field testing device, which can identify insulation faults or dirt on equipment before and after use, or be used for regular preliminary inspections (minimum required).

MV Pole, Rod and Rope Insulation Tester

TT7415

Page 4: MV pole, rod and rope insulation tester

 ■ Specifications of the MV Pole, Rod and Rope Insulation Tester

Tools and materials that can be tested : Insulating Rods : Ø 10 to 15 mm Insulating Sticks and Tubes :

Ø 32-39, 51, 64 and 77 mm Insulating Ropes : Ø 8 to 13 mm

Power supply : battery 12 V Ni-Cd mains AC 100-240 V – 50/60 Hz

approx. dimensions : 190 x 120 x 135 mm approx. mass : 1.5 kg Supplied in a foamed case with battery

charger and “test” tube.

MV Pole, Rod and Rope Insulation Tester TT7415

Page 5: MV pole, rod and rope insulation tester

■ Standard and Environment

MV Pole, Rod and Rope Insulation Tester TT7415

Compliant with LV, RoHS and DEEE European Directives

Page 6: MV pole, rod and rope insulation tester

All our products help utilities to face global challenges providing high safety level for electrical network improvement operations:Preparation / safetyEfficiency / Availability

THE NETWORK WILL CHANGE !

Page 7: MV pole, rod and rope insulation tester

THE NETWORK WILL CHANGE !

Page 8: MV pole, rod and rope insulation tester

THE NETWORK WILL CHANGE !

Page 9: MV pole, rod and rope insulation tester

Work in total confidence

with your powernetwork

Page 10: MV pole, rod and rope insulation tester

HISTORY & FIGURES

1949: creation of the company to supply earthing devices to “compagnie du Rhin” 

1960: creation of the French LiveW competence Center (SERECT) in Mulhouse

1989: building of this building specialy designed around high voltage laboratory

1998: integration in Novarc Group 4800 m², 3500 references, TOP80% 1500 ref / 40 products 330 suppliers, 2M components, 200k end products ISO 9002 in 1996, ISO 9001 since 2002 Export rate > 65% in more than 100 countries


Top Related