Download - Nathaniel Hlavin Catholic University of America APS April Meeting 2011, Anaheim, CA April 29, 2011 1
1
Measurement of Exclusive Kaon Electroproduction
Nathaniel HlavinCatholic University of America
APS April Meeting 2011, Anaheim, CA
April 29, 2011
in Hall C at Jefferson Lab
Meson Reaction Dynamics
• However, before one can learn about form factors and GPDs one has to investigate their prerequisites, e.g., factorization of hard and soft physics • Kaon factorization
• We can learn about meson form factors and nucleon Generalized Parton Distributions (GPDs) from these two diagrams of the meson reaction process
2
Hard Scattering
Fπ,K
GPD
• Depending on Q2, we probe either the meson form factors or the GPDs
Low Q2
High Q2
222 EpQ Energy of the photon (photon virtuality)t is the four-momentum transfer from photon to the target
(nucleon)
t
• Difficult to draw a conclusion from current σL/σT ratios
– Limited W (center of mass energy) and Q2 coverage
– Kaon data in resonance region (W<2 GeV)
– Uncertainties from scaling in x, t
High quality σL and σT data for both kaon and pion would provide important information for understanding the meson reaction mechanism
3
Q2=1.2-2.0 GeV2
Q2=1.9-3.4 GeV2
W<2GeVt=0.2 GeV2
xB=0.3
t=0.4 GeV2
xB=0.4
Q2 (GeV2)
Q2 (GeV2)
ep → e‘K+Λ
ep → e‘π+n
Q2=1.4-2.2 GeV2
Q2=2.7-3.9 GeV2
Q2=1.2-2.0 GeV2
Q2=1.9-3.4 GeV2
Q2 (GeV2)
R=
σ L/σ
TR
=σ L
/σT
x=0.3t=0.2
x=0.5t=0.4
x=0.3t=0.2
x=0.4t=0.4
High Q2: Q-n scaling of σL and σT
• A test is the Q2 dependence of the cross section:
– σL ~ Q-6 to leading order– σT ~Q-8
• To access physics contained in GPDs, one is limited to the kinematic regime where hard-soft factorization applies
Q2 (GeV2)
x is the fraction of longitudinal momentum carried by a quark in a nucleon
T. Horn et al.
JLab 12 GeV: L/T separated kaon cross sectionsσL σT
E12-09-011: Precision data for W > 2.5 GeV
Approved experiment E12-09-011 will provide first L/T separated kaon data above the resonance region (W>2.5 GeV)
• Understanding of hard exclusive reactions
– QCD model building
– Coupling constants
• Onset of kaon factorization
4
• SHMS base detector system provides particle identification for e, π, p over the full momentum range• Noble gas Cherenkov: e/π• Heavy gas Cherenkov: π/K• Lead glass: e/π
• The lack of p/K+ separation does not allow a strange physics program in Hall C at 11 GeV with only the base equipment
5
• The π+/K+ separation is provided by the heavy gas Cerenkov
Need to build kaon aerogel detector for the strangeness program in Hall C
SHMS Detector System – how to measure kaons
Noble gas Cerenkov
Heavy Gas Cerenkov
Lead glass
Kaon Aerogel Project• NSF-MRI Consortium: Development of a Kaon Detection
System� PI: The Catholic University of America (Tanja Horn)� co-PI: University of South Carolina (Yordanka Ilieva)
� co-PI: Mississippi State University (Dipangkar Dutta)
� co-PI: Florida International University (Joerg Reinhold)
• Current Status: MRI awarded by NSF October 2010 (NSF-PHY-1039446)
• Detector design is well underway� PMTs expected to be procured early in 2011 and tested during
summer
6
� co-PI: Catholic University of America (Franz Klein)
� Drawings will be modified from HMS drawings and machining will begin at CUA� Aerogel negotiations underway
SHMS Aerogel Design Overview
PMTs
Aerogel Panels
• Diffusion box will be built as single unit with fourteen 5” PMTs, 7 on each long side of the detector
• Aerogel tray and diffusion lightbox with PMTs based on proven technology
– Allows for simple detector assembly and easy replacement of the aerogel stack
• To cover momenta up to ~6 GeV/c aerogels will have different refractive indices, e.g., n=1.030 and n=1.015
• Active area will be 90x60cm2 with box size 110x100cm2 for future upgrades
• Total depth ~ 30cm along the optical axis of the SHMS
7
1 2 3 4 5 6 7 8 90.00
2.00
4.00
6.00
8.00
10.00
12.00
14.00
16.00
10 cm thick8 cm thick
5 cm thick
Ph
oto
ele
ctro
ns
Momentum (GeV)
n = 1.03
Monte Carlo Simulations of Kaon Signal
8
Expected Performance
• Response function of detector nearly independent of position and momentum
• Used same refractive indices (n=1.015, 1.030) and met with good N.P.E counts.
Data from 6 GeV detector on which our design is based
• Pion Data from HMS Aerogel Detector on which our design is based can give some idea of expected performance.
Total sum of photo-electrons detected by aerogel has a nearly flat distribution in both vertical (X) and horizontal (Y) direction and
momentum
[Asaturyan et al. Nucl. Instrum. Meth. A548: 364, 2005]
9
OutlookTechnical drawings and machining of components
starting in next few monthsPMT procurement complete this springPMT testing and prototype this summer together
with students from Catholic University of America, University of South Carolina, Florida International University, and Mississippi State University
10
Summary
• JLab 12 GeV will allow rigorous tests of factorization in meson production, for instance, kaon factorization
– Extended kinematic reach and studies of additional systems– Essential prerequisite for studies of valence quark
spin/flavor/spatial distributions
• Meson production plays an important role in our understanding of hadron structure
• The kaon aerogel Cerenkov detector adds capability to detect kaons to SHMS to carry out our kaon experiments at 12 GeV
– MRI consortium: CUA, USC, MSU FIU, Yerevan, JLab
Work supported in part by NSF grants PHY-1019521 and PHY-1039446
11
Backup material
1 2 3 4 5 6 7 8 90.00
1.00
2.00
3.00
4.00
5.00
6.00
7.00
8.00
9.00
10.00
Momentum (GeV)
Ph
oto
ele
ctro
ns
90x90 ;
110x100
90x60 (6x6x4)
110x100
110x100
n = 1.015N
EW Bottom
Top
S
N. Hlavin
Monte Carlo Simulations of Kaon Signal
Top and
bottom?
Left and
right?
How many PMTs?
PMTs on one wall
PMTs on two walls
PMTs on three walls
Design Studies: PMT placement
• To optimize performance and facilitate access the PMTs will be mounted on the vertical sides of the box
12
PID at higher momenta
• Up to about 4 GeV/c, the p/K+ separation can be achieved with a refractive index of n=1.030
13
• Up to about 6 GeV/c, n=1.015 can provide adequate p/K+ separation
0.00 1.00 2.00 3.00 4.00 5.00 6.00 7.00 8.00 9.000
5
10
15
20
25 Index: 1.03
Kaon
Proton
Np.e.
Momentum (GeV/c)
0.00 1.00 2.00 3.00 4.00 5.00 6.00 7.00 8.00 9.000
2
4
6
8
10
12Index: 1.015
Kaon
Proton
Momentum (GeV/c)
Np.e.
N. Hlavin, S. Rowe
pSHMS n Kpe ppe Discrimination (5 σ)
3.0 1.030 (1.015)
27 (2) <0.5 (<0.5)
>1000:1 (lower)
3.5 1.030 (1.015)
34 (9) <0.5 (<0.5)
>1000:1 (lower)
3.9 1.030 (1.015)
36 (12) 2 (<0.5) >1000:1 (lower)
4.5 1.030 1.015
40 15 13 <0.5 1000:1 >1000:1
5.2 (1.030) 1.015
(42) 18 (24) <0.5 (30:1) >1000:1
5.5 (1.030) 1.015
(43) 19 (26) 1 (20:1) >1000:1
6.1 (1.030) 1.015
(44) 20 (31) 6 (10:1) 200:1
Con
trib
uti
on
of
kn
ock
-on
ele
ctro
ns
is 2
%
PID at higher momenta
• For higher momenta, p/K+ separation is less of an issue
– Kaon rate becomes larger than the proton rate
– Easier to deal with non-peaked proton background
14
Prediction coincides with Hall C kaon experiment (E93-108)• Advantage of using n=1.03, 1.015
is that they are the standard indices offered by Panasonic (successor of Matsushita)
– Currently no option to manufacture and export aerogels with indices smaller than n=1.015 in large quantities
Prediction of rates for kaons and protons
For flexibility and to allow for future upgrades, design of detector will support use of aerogel with any index of
refraction
• Future upgrade option for third index, e.g., n=1.0075 would give p/K+ 1000:1 at p=7.1 GeV/c (available from Novosibirsk)
PMT Procurement
• Negotiations with MIT/Bates about PMTs from ASU detectors from BLAST experiment
– Together with Yerevan group we will evaluate the PMTs this spring
• Procurement of PMTs will be completed this spring and extensive testing during the summer at JLab and CUA
– Hamamatsu model R1250
– Photonis XP4500B
• Currently developing testing procedures using PMTs from HKS experiment *
15
*Thanks to Liguang Tang (HU), Joerg Reinhold (FIU), Tohuku University
• Constructed test setup and checked with cosmic rate
16
SHMS (e,e’K+) Program in Hall C
• Range of kaon momenta that needs to be covered largely given by the Kaon factorization experiment
• To date four experiments have been approved for Hall C at 11 GeV
Experiment Physics Motivation SHMS Momenta (GeV/c)
Worst Fore/Bkd Rate Ratio
Color Transparency (E12-06-107)
• vanishing of h-N interaction at high Q.• exclusive π, K production from nuclei.
5.1-9.6 1(K):10(p)
SIDIS pT
(E12-09-017)
• extract mean kT of u,d,s quarks in proton.• SIDIS π±, K± production.
1.5-5.0
SIDIS R(E12-06-104)
• Measure the ratio R=σL/σT
• SIDIS, π±, K± production.
1.5-5.0
Kaon Factorization(E12-09-011)
• study of soft-hard factorization in exclusive K+ production.
• L/T separations vs. Q2, t.
2.6-7.1 1(K):3(p)
There is a strong kaon program proposed for Hall C. We need a kaon detector!
With two-sided PMT readout, a summed Npe signal is uniform within 10% of the active area of the detector
H. Mkrtchyan
Design studies: length and width of box
Baseline configuration:
• 110x100x24.5 cm3 box
• 90x60 cm2 aerogel active area
• Active area of 90x60 cm2 covers the envelope of scattered particles from 10 cm targets
• To leave the option to cover the tails from the 40 cm target, detector box will have area 110x100 cm2
Box PMTs n Npe
110x100x30 7+7 1.015 7.60
110x80x30 7+7 1.015 8.14
Box PMTs n Npe
110x100x30 7+7 1.030 14.99
110x80x30 7+7 1.030 16.07
• Further reduction of box width by 20% (40%) only improves yield by 7% (15%) making further optimization unnecessary
Simulation* of kaon signal
*D. Higinbotham, NIM A414, 332 (1998)
17
Design studies: PMT selection
Box PMTs
n Npe
110x100x30
7+7 1.015 7.60
110x100x30
7+7 1.030 14.99
Box PMTs
n Npe
120x100x30
8+8 1.015 7.86
120x100x30
8+8 1.030 15.44
H. Mkrtchyan
• Minimum distance between 5” PMTs centers must be 5.875” (14.92 cm)
• For 110 cm detector height can fit seven 5” PMTs from each side
• Gain for increasing height to fit eight 5” PMTs from each side is negligible
• Effective coverage for 7 5” PMTs is 5.1%
– With nine 4” PMTs this would be reduced to 4.2%
18