NCR Personas M Series 76Automated Teller MachineSite Preparation
B006-6453-B0001104
FEDERAL COMMUNICATIONS COMMISSION (FCC) RADIO FREQUENCY INTERFERENCE STATEMENT
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Canadian Class A Device Declaration
This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications.
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la classe A prescrites dans le Réglement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada.
Information to User
This equipment must be installed and used in strict accordance with the manufacturer’s instructions. However, there is no guarantee that interference to radio communications will not occur in a particular commercial installation. If this equipment does cause interference, which can be determined by turning the equipment off and on, the user is encouraged to consult an NCR service representative immediately.
CAUTION
NCR Corporation is not responsible for any radio or television interference caused by unauthorised modifications of this equipment or the substitution or attachment of connecting cables and equipment other than those specified by NCR. Such unauthorized modifications, substitutions, or attachments may void the user’s authority to operate the equipment. The correction of interference caused by such unauthorized modifications, substitutions, or attachments will be the responsibility of the user.
The ATM complies with the following Electromagnetic Compatibility (EMC) directives and standards for IT equipment:
• 89/336/EEC ‘EMC Directive’• 92/31/EEC ‘Amending EMC Directive’• 93/68/EEC ‘CE Marking Directive’.
For further information, refer to the Electromagnetic Compatibility (EMC) and Safety section.
NOTICEThis is a contractual document. It contains important warnings and confers important legal rights and obligations. You are advised to read it carefully.
It is the responsibility of the customer to assure that all installation preparations are complete and in compliance with all specifications and requirements of NCR and all applicable national, state, or local codes, regulations and laws.
The product described in this book is a licensed product of NCR Corporation.
NCR and Personas are trademarks of NCR Corporation.
Other product names mentioned in this publication may be trademarks or registered trademarks of their respective companies and are hereby acknowledged.
It is the policy of NCR Corporation (NCR) to improve products as new technology, components, software, and firmware become available. NCR, therefore, reserves the right to change specifications without prior notice.
All features, functions, and operations described herein may not be marketed by NCR in all parts of the world. In some instances, photographs are of equipment prototypes. Therefore, before using this document, consult with your NCR representative or NCR office for information that is applicable and current.
© 2004By NCR Corporation, Dayton, Ohio U.S.A.http://www.ncr.comAll Rights Reserved
Table of Contents
Personas M Series 76 ATM Site Preparation
INTRODUCTION ...............................................................................................................1How to Use This Site Preparation Bookset ....................................................................1Purpose and Audience ....................................................................................................2Site Compliance ..............................................................................................................2Customer Responsibilities ..............................................................................................3Product Identification .....................................................................................................3
PACKAGE DIMENSIONS.................................................................................................5Manoeuvring the ATM Into Position..............................................................................6
ATM DIMENSIONS...........................................................................................................7Front Access ...................................................................................................................7Rear Access.....................................................................................................................8
UL Security Enclosure ...............................................................................................8CEN Security Enclosure ............................................................................................9
Privacy Panels...............................................................................................................10
ACCESS FOR ALL...........................................................................................................11Height and Depth to Main Facia Items.........................................................................11
Topmost Viewable Facia Item .................................................................................12Task Lighting................................................................................................................12Wheelchair Clearance ...................................................................................................12
ATM CONFIGURATIONS AND ASSOCIATED CLEARANCES ...............................13Traditional Full Function ATM ....................................................................................13Currency Dispenser.......................................................................................................14Currency Deposit ..........................................................................................................14Currency Recycle (Deposit/Dispense) ..........................................................................15Currency (Deposit/Dispense)........................................................................................15High Currency Recycle (Deposit/Dispense).................................................................16
B006-6453-B000 i
INSTALLATION AND SERVICE CLEARANCES........................................................17Front Access Clearances ...............................................................................................17
Clearance A - Front Access UL Security Enclosure................................................17Clearance B - Front Access UL Security Enclosure ................................................18Clearance C - Front Access CEN Security Enclosure .............................................19Clearance D - Front Access CEN Security Enclosure .............................................20
Rear Access Clearances ................................................................................................21Clearance E - Rear Access UL Security Enclosure .................................................21Clearance F - Rear Access UL Security Enclosure..................................................22Clearance G - Rear Access CEN Security Enclosure ..............................................23Clearance H - Rear Access CEN Security Enclosure ..............................................24
REQUIREMENTS FOR THE FLOOR.............................................................................25Floor Covering..............................................................................................................25Floor Loading ...............................................................................................................25Bolt Holes Locations ....................................................................................................26
Front Access.............................................................................................................26Rear Access..............................................................................................................28
Security Bolts................................................................................................................30
VIDEO CAMERA.............................................................................................................31Ambient Lighting..........................................................................................................31Internal Space Constraint for Fitting a Third-Party Video Camera ..............................32
ii B006-6453-B000
Personas M Series 76 ATM Site Preparation
Table of Contents
Personas M Series 76 ATM Site Preparation
INTRODUCTION
How to Use This Site Preparation BooksetThe site preparation is part of the Personas M Series 76 Site Preparation Bookset. It acts both as a specifications book, and also as a gateway to the other books in the bookset, which are:
● Electrical and Protection Requirements (B006-6454)
● Environmental and Planning Requirements (B006-6455)
B006-6453-B000 1
Personas M Series 76 ATM Site Preparation
Purpose and AudienceThis book is intended for architects and those responsible for preparing a site prior to the arrival of the NCR Personas M Series 76 Automated Teller Machine (ATM).
Site preparation details are given under the following main sections within this book:
Package Dimensions
ATM Dimensions
Access for All
ATM Configurations
Installation and Service Clearances
Requirements for the Floor
Video Camera
Site ComplianceThis document contains the information necessary for the preparation of a site conforming to NCR specifications. It is very important that the site complies with the requirements specified in this document because, once the equipment has been installed, deficiencies in site preparation or the problems caused by these deficiencies are much more difficult to detect and correct. Further, failure to comply with these requirements or to take proper steps to protect equipment against risks identified in this document may cause serious damage to the equipment and to the customer’s business.
In addition to the need to comply with the requirements specified, electrical wiring and mechanical systems must also comply with all relevant codes, laws and regulations.
It is important that the site be prepared by a customer or his agent who is fully conversant with the special requirements of electronic equipment. The responsibility for ensuring that the site is prepared in compliance with this document remains with the customer.
For information and guidance only, a list is provided, in general terms, of those matters for which the customer is responsible. This list is not intended to be comprehensive, and in no way modifies, alters, or limits the responsibility of the customer for all aspects of adequate site preparation.
NCR staff will be available to answer questions relating to the contents of this document but, except where:
a the customer has been notified that a full or partial consultancy service is available and/or that NCR will be willing to undertake a preliminary or final site survey and
b the customer shall have entered into a formal contract with NCR for provision of the same
no comment, suggestion or advice offered or not offered about preparation of the site nor any inspection of the site whether before or after preparation is to be taken as approval of the location of the site and equipment or of its preparation and NCR will not be liable in
2 B006-6453-B000
Personas M Series 76 ATM Site Preparation
respect of any comment, suggestion or advice given by its staff or in respect of any failure to give advice.
Finally, only the customer can know the full extent of damage which may be caused to his business by reason of failure of the equipment which is to be installed. For this reason it is the customer’s responsibility to ascertain the extent of any such possible damage to his existing or planned business, and to effect full insurance in respect of it.
Customer ResponsibilitiesThe customer must do or provide the following:
● When required by NCR, provide the NCR customer service representative with appropriate drawings that indicate:
● Location of the equipment
● Site wiring (power and signal, paths and lengths)
● Location of other equipment capable of generating electrical noise, electromagnetic interference, heat, etc.
● Make building alterations necessary to meet wiring and other site requirements.
● Provide and install all communications cables, wall jacks, special connectors, and associated hardware.
● Provide and install necessary power distribution boxes, conduits, grounds, lightning protection, and associated hardware.
● Make sure all applicable codes, regulations and laws (including, but not limited to, electrical, building, safety, and health) are met.
● Provide and install auxiliary power or other equipment as required.
● Provide storage or service areas as required.
● Make sure the environmental requirements of the system/unit are met.
● Provide floor coverings and environmental systems that limit or control static electricity build-up and discharge.
● Install the product at a height which meets the accessibility regulations of the relevant country.
Product IdentificationThe product is identified by a class type number, 6676, and a 4 digit model number, (normally 0100), which is printed on a label fixed inside the top cabinet of the ATM and above the receipt printer. The serial number is unique to each ATM. The tracer number is
B006-6453-B000 3
Personas M Series 76 ATM Site Preparation
used to identify where the ATM was built. Please quote all of the serial and tracer numbers, including the prefix, when making reference to the ATM.
Model: XXXX
Hz: 50/60 A:X.X
Serial: XX-XXXXXXXX
Tracer: XX-XXXXX
Vac: XXX
NCR Global Solutions Ltd.
Made in UK
Electromagnetic Compatibility
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:(1) This device may not cause harmful interference, and (2) this device must accept any interferencereceived, including interference that may cause undesired operation.
This apparatus does not exceed Class A limits for radio noise emissions set out in the Radio InterferenceRegulations of Canada.
‘’Complies with FDA Radiation Performance Standards, 21 CFR Subchapter J’‘
Le present appariel n’emet pas de bruits radioelectriques depassant les limites de la classe A prescritesdans le Reglement sur le brouillage radioelectrique du Canada.
Class: 6676
� LR 32207�
LISTED649Automated Teller Machine24 Hour Service Level 1
UL
4 B006-6453-B000
Personas M Series 76 ATM Site Preparation
PACKAGE DIMENSIONSThe dimensions of a packaged and unpackaged ATM are shown below.
UL and CEN Front Access
UL Rear Access
CEN Rear Access
A 1047 mm(41.22 in.)
1107 mm(43.58 in.)
1133 mm(44.61 in.)
1391 mm
(54.76 in.)
928 mm
(36.54 in.)
1806 mm
(71.10 in.)
1319 mm
(51.93 in.)
880 mm
(34.65 in.)
A
785 mm
(30.91 in.)
B006-6453-B000 5
Personas M Series 76 ATM Site Preparation
Manoeuvring the ATM Into PositionEnsure that doorways and corridors leading to your point of installation are wide enough to allow the package to pass through, or make arrangements to unpack the ATM in an area with sufficient access and then move it to the installation site. Also ensure that any corridors can support the weight of the ATM. Refer to page 25 for the maximum weight of the ATM and its floor loading.
The following table gives the minimum dimensions for doorways, corridors with right angle corners and the space required to rotate an ATM on its axis.
Note 1: The dimensions assume the ATM is being moved using equipment that does not extend beyond the ATM or packaging.
Note 2: A surrounding clearance of 6 mm (0.24 in.) has been allowed in the figures.
Note 3: If privacy panels are fitted, the dimensions for an unpackaged ATM will increase by 20 mm (0.79 in.). If the doorway is not wide enough to allow an ATM with privacy panels to pass through, the panels can be removed and installed at a later date.
Packaged ATM(pallet, carton
and lid)
Packaged ATM(pallet and
carton)
Unpackaged ATM
(UL and CEN Front Access)
Unpackaged ATM
(UL Rear Access)
Unpackaged ATM
(CEN Rear Access)
A Doorway or straight corridor
940 mm(37.01 in.)
892 mm(35.12 in.)
797 mm(31.38 in.)
797 mm(31.38 in.)
797 mm(31.38 in.)
B Corridor with corner 1160 mm(45.67 in.)
1101 mm(43.35 in.)
937 mm(36.89 in.)
958 mm(37.72 in.)
968 mm(38.11 in.)
C Rotation about centre 1684 mm(66.30 in.)
1598 mm(62.91 in.)
1321 mm(52.01 in.)
1369 mm(53.90 in.)
1390 mm(54.73 in.)
A B
B
C
6 B006-6453-B000
Personas M Series 76 ATM Site Preparation
ATM DIMENSIONS
Front AccessThe illustration below shows the dimensions for an ATM configured with a UL, CEN Grade III or CEN Grade IV LGAI security enclosure.
800 mm
(31.50 in.)785 mm
(30.91 in.)
97 mm
(3.82 in.)
1286 mm
(50.63 in.)
596 mm
(23.46 in.)
770 mm
(30.31 in.)
45 mm
(1.77 in.)
1047 mm
(41.22 in.)
818 mm
(32.20 in.)
1911 mm
(75.24 in.)
2316 mm
(91.18 in.)
1550 mm
(61.02 in.)
92 mm
(3.62 in.)
775 mm
(30.51 in.)
760 mm
(29.92 in.)
Service Positionfor Facia Items
B006-6453-B000 7
Personas M Series 76 ATM Site Preparation
Rear Access
UL Security Enclosure
The illustration below shows the dimensions for an ATM configured with a UL security enclosure.
800 mm
(31.50 in.)785 mm
(30.91 in.)
97 mm
(3.82 in.)
760 mm
(29.92 in.)
770 mm
(30.31 in.)
810 mm
(31.89 in.)
45 mm
(1.77 in.)60 mm
(2.36 in.)
1107 mm
(43.58 in.)
818 mm
(32.20 in.)
1550 mm
(61.02 in.)
92 mm
(3.62 in.)
775 mm
(30.51 in.)
1552 mm
(61.10 in.)
1911 mm
(75.24 in.)
8 B006-6453-B000
Personas M Series 76 ATM Site Preparation
CEN Security Enclosure
The illustration below shows the dimensions for an ATM configured with a CEN Grade III or CEN Grade IV LGAI security enclosure.
800 mm
(31.50 in.)785 mm
(30.91 in.)
97 mm
(3.82 in.)
760 mm
(29.92 in.)
770 mm
(30.31 in.)
45 mm
(1.77 in.)
92 mm
(3.62 in.)
1133 mm
(44.61 in.)
775 mm
(30.51 in.)
818 mm
(32.20 in.)
1550 mm
(61.02 in.)
810 mm
(31.89 in.)
86 mm
(3.39 in.)
1578 mm
(62.13 in.)
1911 mm
(75.24 in.)
B006-6453-B000 9
Personas M Series 76 ATM Site Preparation
Privacy PanelsThe illustration below shows the ATM with privacy panels fitted to either side of the facia. The dimensions are the same for ATMs configured with a UL, CEN Grade III or CEN Grade IV LGAI security enclosure.
1037 mm
(40.83 in.)
805 mm
(31.69 in.)
1325 mm
(52.17 in.)
10 B006-6453-B000
Personas M Series 76 ATM Site Preparation
ACCESS FOR ALLThe ATM has been designed to meet the height and reach requirements of the ATM user population of the world, both able-bodied and disabled. For wheelchair users, the ATM offers optimised parallel approach, providing easy access, security and private space if installed according to the specifications detailed in this document.
Height and Depth to Main Facia ItemsThe following table gives the height and depth to the main facia items located on the facia. All the height dimensions are calculated from the base of the ATM.
A B C D E F G H I J K L
Statement Touch ScreenDisplay
Cash Exitand/orEntry
No. 5 Key EnvelopeExit and
Entry
Audio Jack Plug
Card Reader
Motorised
Card Reader
Dip
Receipt Camera Window
3rd-Party Camera Window
Top FDK
Height (from base of ATM)
1200 mm(47.24 in.)
1144 mm(45.04 in.)
848 mm(33.39 in.)
805 mm(31.69 in.)
848 mm(33.39 in.)
943 mm(37.13 in.)
1075 mm(42.32 in.)
1075 mm(42.32 in.)
1200 mm(47.24 in.)
1278 mm(50.31 in.)
1426 mm(56.14 in.)
1055 mm(41.54 in.)
Depth (from front of shelf)
242 mm(9.53 in.)
266 mm(10.47 in.)
193 mm(7.60 in.)
94 mm(3.70 in.)
193 mm(7.60 in.)
158 mm(6.22 in.)
177 mm(6.97 in.)
157 mm(6.18 in.)
195 mm(7.68 in.)
216 mm(8.50 in.)
260 mm(10.24 in.)
233 mm(9.17 in.)
SS 5JKL
A C
E
B FC
E
G
H
J KD I L
B006-6453-B000 11
Personas M Series 76 ATM Site Preparation
Topmost Viewable Facia Item
The following illustration shows the projected angle from the front of the facia to the topmost viewable facia item.
Task LightingA minimum of 200 LUX is recommended for task lighting.
Wheelchair ClearanceThe following illustration shows the clearance required for wheelchair approach and its turning circle.
59ºStatement
1524 mm
(60.0 in.)
1524 mm
(60.0 in.)
12 B006-6453-B000
Personas M Series 76 ATM Site Preparation
ATM CONFIGURATIONS AND ASSOCIATED CLEARANCES
If it is likely that the ATM will be fitted with intelligent deposit, currency deposit or high currency recycle (cash acceptor or cash recycler) at a later date, the currency dispenser should be fitted in the right-hand bay. This will ensure that the installation and service clearances will remain as small as possible and the same as those shown in clearances A, C, E and G.
Traditional Full Function ATM
Left-Hand Bay Right-Hand Bay Left-Hand Bay Right-Hand Bay
Currency Dispenser Envelope Depository Envelope Depository Currency Dispenser
Front Access Front Access
Clearance A - UL Security See page 17. Clearance A - UL Security See page 17.
Clearance C - CEN Security See page 19. Clearance C - CEN Security See page 19.
Rear Access Rear Access
Clearance E - UL Security See page 21. Clearance E - UL Security See page 21.
Clearance G - CEN Security See page 23. Clearance G - CEN Security See page 23.
EnvelopeDepository
CurrencyDispenser
EnvelopeDepository
CurrencyDispenser
B006-6453-B000 13
Personas M Series 76 ATM Site Preparation
Currency Dispenser
Currency Deposit
Left-Hand Bay Right-Hand Bay Left-Hand Bay Right-Hand Bay
Currency Dispenser Currency Dispenser
Front Access Front Access
Clearance A - UL Security See page 17. Clearance A - UL Security See page 17.
Clearance C - CEN Security See page 19. Configuration not available for CEN Security
Rear Access Rear Access
Clearance E - UL Security See page 21. Clearance E - UL Security See page 21.
Clearance G - CEN Security See page 23. Configuration not available for CEN Security
Left-Hand Bay Right-Hand Bay Left-Hand Bay Right-Hand Bay
Cash Acceptor Cash Acceptor
Front Access Front Access
Clearance B - UL Security See page 18. Clearance A - UL Security See page 17.
Clearance D - CEN Security See page 20. Configuration not available for CEN Security
Rear Access Rear Access
Clearance F - UL Security See page 22. Clearance E - UL Security See page 21.
Clearance H - CEN Security See page 24. Configuration not available for CEN Security
CurrencyDispenser
CurrencyDispenser
CashAcceptor
CashAcceptor
14 B006-6453-B000
Personas M Series 76 ATM Site Preparation
Currency Recycle (Deposit/Dispense)
Currency (Deposit/Dispense)
Left-Hand Bay Right-Hand Bay Left-Hand Bay Right-Hand Bay
Cash Recycler Cash Recycler
Front Access Front Access
Clearance B - UL Security See page 18. Clearance A - UL Security See page 17.
Clearance D - CEN Security See page 20. Configuration not available for CEN Security
Rear Access Rear Access
Clearance F - UL Security See page 22. Clearance E - UL Security See page 21.
Clearance H - CEN Security See page 24. Configuration not available for CEN Security
Left-Hand Bay Right-Hand Bay Left-Hand Bay Right-Hand Bay
Currency Dispenser Cash Acceptor Cash Acceptor Currency Dispenser
Front Access Front Access
Clearance B - UL Security See page 18. Clearance A - UL Security See page 17.
Clearance D - CEN Security See page 20. Configuration not available for CEN Security
Rear Access Rear Access
Clearance F - UL Security See page 22. Clearance E - UL Security See page 21.
Clearance H - CEN Security See page 24. Configuration not available for CEN Security
CashRecycler
CashRecycler
CurrencyDispenser
CashAcceptor
CashAcceptor
CurrencyDispenser
B006-6453-B000 15
Personas M Series 76 ATM Site Preparation
High Currency Recycle (Deposit/Dispense)
Left-Hand Bay Right-Hand Bay Left-Hand Bay Right-Hand Bay
Currency Dispenser Cash Recycler Cash Recycler Currency Dispenser
Front Access Front Access
Clearance B - UL Security See page 18. Clearance A - UL Security See page 17.
Clearance D - CEN Security See page 20. Configuration not available for CEN Security
Rear Access Rear Access
Clearance F - UL Security See page 22. Clearance E - UL Security See page 21.
Clearance H - CEN Security See page 24. Configuration not available for CEN Security
CurrencyDispenser
CashRecycler
CurrencyDispenser
CashRecycler
16 B006-6453-B000
Personas M Series 76 ATM Site Preparation
INSTALLATION AND SERVICE CLEARANCESThe following illustrations show the minimum areas required for installing and servicing the ATM.
Note 1: Increasing the area around the ATM will improve service access.
Note 2: The installation and service clearances in this section are the same as the minimum clearances for 5675 and 5875.
Front Access Clearances
Clearance A - Front Access UL Security Enclosure
The illustration below shows the dimensions for an ATM configured with a UL security enclosure and currency dispenser or envelope depository in the right-hand bay.
48 mm
(1.89 in.)
58 mm
(2.28 in.)
886 mm
(34.88 in.)
1281 mm
(50.43 in.)
770 mm
(30.31 in.)
2228 mm
(87.72 in.)
470 mm
(18.50 in.)488 mm
(19.21 in.)
838 mm
(32.99 in.)
1376 mm
(54.17 in.)
1339 mm
(52.72 in.)
136.5º
Cur
renc
yD
ispe
nser
Env
elop
eD
epos
itory
B006-6453-B000 17
Personas M Series 76 ATM Site Preparation
Clearance B - Front Access UL Security Enclosure
The illustration below shows the dimensions for an ATM configured with a UL security enclosure and cash acceptor or cash recycler in the right-hand bay.
48 mm
(1.89 in.)
58 mm
(2.28 in.)
886 mm
(34.88 in.)
770 mm
(30.31 in.)
2228 mm
(87.72 in.)
470 mm
(18.50 in.)
300 mm
(11.81 in.)
488 mm
(19.21 in.)
838 mm
(32.99 in.)
1376 mm
(54.17 in.)
1639 mm
(64.53 in.)
1281 mm
(50.43 in.)
136.5º
Cur
renc
yD
ispe
nser
Cas
hA
ccep
tor
orC
ash
Rec
ycle
r
18 B006-6453-B000
Personas M Series 76 ATM Site Preparation
Clearance C - Front Access CEN Security Enclosure
The illustration below shows the dimensions for an ATM configured with a CEN Grade III or CEN Grade IV LGAI security enclosure, and currency dispenser or envelope depository in the right-hand bay.
48 mm
(1.89 in.)
58 mm
(2.28 in.)
140º
886 mm
(34.88 in.)
1422 mm
(55.98 in.)
1338 mm
(52.68 in.)
770 mm
(30.31 in.)
2228 mm
(87.72 in.)
470 mm
(18.50 in.)488 mm
(19.21 in.)
838 mm
(32.99 in.)
1320 mm
(51.97 in.)
Cur
renc
yD
ispe
nser
Env
elop
eD
epos
itory
B006-6453-B000 19
Personas M Series 76 ATM Site Preparation
Clearance D - Front Access CEN Security Enclosure
The illustration below shows the dimensions for an ATM configured with a CEN Grade III or CEN Grade IV LGAI security enclosure, and cash acceptor or cash recycler in the right-hand bay.
48 mm
(1.89 in.)
58 mm
(2.28 in.)
140º
886 mm
(34.88 in.)
1722 mm
(67.80 in.)
1338 mm
(52.68 in.)
770 mm
(30.31 in.)
2228 mm
(87.72 in.)
838 mm
(32.99 in.)
1320 mm
(51.97 in.)
470 mm
(18.50 in.)488 mm
(19.21 in.)
300 mm
(11.81 in.)
Cas
hA
ccep
tor
orC
ash
Rec
ycle
r
Cur
renc
yD
ispe
nser
20 B006-6453-B000
Personas M Series 76 ATM Site Preparation
Rear Access Clearances
Clearance E - Rear Access UL Security Enclosure
The illustration below shows the dimensions for an ATM configured with a UL security enclosure and currency dispenser or envelope depository in the right-hand bay.
104 mm
(4.09 in.)
58 mm
(2.28 in.)
136.5º
886 mm
(34.88 in.)
1339 mm
(52.72 in.)
1281 mm
(50.43 in.)
770 mm
(30.31 in.)
3015 mm
(118.70 in.)
680 mm
(26.77 in.)
1626 mm
(64.02 in.)
375 mm
(14.76 in.)393 mm
(15.47 in.)
Env
elop
eD
epos
itory
Cur
renc
yD
ispe
nser
B006-6453-B000 21
Personas M Series 76 ATM Site Preparation
Clearance F - Rear Access UL Security Enclosure
The illustration below shows the dimensions for an ATM configured with a UL security enclosure and cash acceptor or cash recycler in the right-hand bay.
104 mm
(4.09 in.)
58 mm
(2.28 in.)
136.5º
886 mm
(34.88 in.)
1639 mm
(64.53 in.)
1281 mm
(50.43 in.)
770 mm
(30.31 in.)
3015 mm
(118.70 in.)
680 mm
(26.77 in.)
1626 mm
(64.02 in.)
375 mm
(14.76 in.)393 mm
(15.47 in.)
300 mm
(11.81 in.)
Cur
renc
yD
ispe
nser
Cas
hA
ccep
tor
orC
ash
Rec
ycle
r
22 B006-6453-B000
Personas M Series 76 ATM Site Preparation
Clearance G - Rear Access CEN Security Enclosure
The illustration below shows the dimensions for an ATM configured with a CEN Grade III or CEN Grade IV LGAI security enclosure, and currency dispenser or envelope depository in the right-hand bay.
104 mm
(4.09 in.)
58 mm
(2.28 in.)
140º
886 mm
(34.88 in.)
1422 mm
(55.98 in.)
1338 mm
(52.68 in.)
770 mm
(30.31 in.)
3015 mm
(118.70 in.)
650 mm
(25.59 in.)
375 mm
(14.76 in.)393 mm
(15.47 in.)
1626 mm
(64.02 in.)
Env
elop
eD
epos
itory
Cur
renc
yD
ispe
nser
B006-6453-B000 23
Personas M Series 76 ATM Site Preparation
Clearance H - Rear Access CEN Security Enclosure
The illustration below shows the dimensions for an ATM configured with a CEN Grade III or CEN Grade IV LGAI security enclosure, and cash acceptor or cash recycler in the right-hand bay.
104 mm
(4.09 in.)
58 mm
(2.28 in.)
140º
886 mm
(34.88 in.)
1722 mm
(67.80 in.)
1338 mm
(52.68 in.)
770 mm
(30.31 in.)
3015 mm
(118.70 in.)
650 mm
(25.59 in.)
1626 mm
(64.02 in.)
375 mm
(14.76 in.)393 mm
(15.47 in.)
300 mm
(11.81 in.)
Cur
renc
yD
ispe
nser
Cas
hA
ccep
tor
orC
ash
Rec
ycle
r
24 B006-6453-B000
Personas M Series 76 ATM Site Preparation
REQUIREMENTS FOR THE FLOOR
Floor CoveringAn antistatic floor covering should be used and must be of a type that will not generate dust or fluff. The surface on which the ATM is to be sited should be level, smooth and even. In locations where the floor may be uneven, it is recommended that a steel plate is used under the ATM.
Floor LoadingThe ATM must be installed on a floor capable of supporting the maximum weight. Only the maximum weight should be considered as additional options may be added after installation.
UL CEN Grade III or CEN Grade IV LGAI
Front and Rear Access
FrontAccess
RearAccess
Maximum weight 818 kg (1803.7 lb.)
993 kg (2189.6 lb.)
993 kg (2189.6 lb.)
Floor loading 1327.9 kg/m2 (272.0 lb./ft2)
1666.2 kg/m2 (341.2 lb./ft2)
1612.0 kg/m2 (330.1 lb./ft2)
B006-6453-B000 25
Personas M Series 76 ATM Site Preparation
Bolt Holes LocationsThe following illustrations show a plan of the base of the ATM (viewed from above). The plans should be used for pre-drilling bolt holes and illustrates the design for the steel plate, if used.
Front Access
UL Security Enclosure Bolt Hole Locations The illustration below shows the dimensions for an ATM configured with a UL security enclosure.
Note: The boundary marked with an ‘A’ shows the cable access hole for all cables.
285 mm
(11.22 in.)
179 mm
(7.05 in.)
384 mm
(15.12 in.)
800 mm
(31.50 in.)
32 mm
(1.26 in.)43 mm
(1.69 in.)
23 mm
(0.91 in.)
35 mm
(1.38 in.)
426 mm
(16.77 in.)
270 mm
(10.63 in.)
770 mm
(30.31 in.)
Ø 28 mm
(1.10 in.)
Front of ATM
A4 Places
26 B006-6453-B000
Personas M Series 76 ATM Site Preparation
CEN Security Enclosure Bolt Hole Locations The illustration below shows the dimensions for an ATM configured with a CEN Grade III or CEN Grade IV LGAI security enclosure.
Note 1: The hole marked with a ‘B’ enables a security alarm sensor to be fitted.
Note 2: The boundary marked with a ‘C’ shows the cable access hole for all cables.
285 mm
(11.22 in.)
179 mm
(7.05 in.)
774 mm
(30.47 in.)
65 mm
(2.56 in.)
326 mm
(12.83 in.)426 mm
(16.77 in.)
270 mm
(10.63 in.)
770 mm
(30.31 in.)
x
28 mm
(1.10 in.)
60 mm
(2.36 in.)25 mm
(0.98 in.)x
28 mm
(1.10 in.)
45 mm
(1.77 in.)20 mm
(0.79 in.)
Ø
Ø
Ø
Ø
384 mm
(15.12 in.)
32 mm
(1.26 in.)
Front of ATM
B
C
B
A
A
A A
A
Counterbore DeepCounterbore Deep
B006-6453-B000 27
Personas M Series 76 ATM Site Preparation
Rear Access
UL Security Enclosure Bolt Hole Locations The illustration below shows the dimensions for an ATM configured with a UL security enclosure.
Note: The boundary marked with an ‘A’ shows the cable access hole for all cables.
285 mm
(11.22 in.)
234 mm
(9.21 in.)
800 mm
(31.50 in.)
43 mm
(1.69 in.)
23 mm
(0.91 in.)
35 mm
(1.38 in.)
426 mm
(16.77 in.)
270 mm
(10.63 in.)
770 mm
(30.31 in.)
Ø 28 mm
(1.10 in.)
384 mm
(15.12 in.)
32 mm
(1.26 in.)
Front of ATM
A
4 Places
28 B006-6453-B000
Personas M Series 76 ATM Site Preparation
CEN Security Enclosure Bolt Hole Locations The illustration below shows the dimensions for an ATM configured with a CEN Grade III or CEN Grade IV LGAI security enclosure.
Note 1: The hole marked with a ‘B’ enables a security alarm sensor to be fitted.
Note 2: The boundary marked with a ‘C’ shows the cable access hole for all cables.
x
28 mm
(1.10 in.)
60 mm
(2.36 in.)25 mm
(0.98 in.)x
28 mm
(1.10 in.)
45 mm
(1.77 in.)20 mm
(0.79 in.)
285 mm
(11.22 in.)134 mm
(5.28 in.)
800 mm
(31.50 in.)
65 mm
(2.56 in.)
426 mm
(16.77 in.)
234 mm
(9.21 in.)
270 mm
(10.63 in.)
770 mm
(30.31 in.)
Ø
Ø
Ø
Ø
384 mm
(15.12 in.)
32 mm
(1.26 in.)
Counterbore DeepCounterbore Deep
Front of ATM
B
B
A
A
A A
A
C
B006-6453-B000 29
Personas M Series 76 ATM Site Preparation
Security Bolts The ATM should be bolted to the floor, through the ‘A’ holes, using four bolts with anchor washers. The floor must be capable of withstanding the loading imposed by the anchor points for the bolts. The bolts and anchors must be supplied by the owning organisation.
The minimum specification for bolts, to secure the ATM through any security enclosure to a concrete floor, is high tensile M16 bolts with appropriate anchor washers of 6 mm (0.24 in.) minimum thickness. It is recommended that these bolts be a minimum depth of 150 mm (5.91 in.) and that either resin anchor bolts or rawl type bolts are used.
Note 1: Bolting of CEN security enclosures should comply with the requirements of EN 1143-1 (CEN Safe Burglary Standard).
Note 2: For CEN security enclosures, the centre bolt hole ‘B’ in the floor is counterbored to a larger diameter than the other four. This enables a security alarm sensor to be fitted through the hole.
30 B006-6453-B000
Personas M Series 76 ATM Site Preparation
VIDEO CAMERA
Ambient LightingIf the ATM is fitted with a video camera, it is strongly recommended that there is a minimum of 50 LUX lighting at floor level within the area illustrated below. This lighting level conforms to:
● Australian Standard for Automatic Teller Machines (1990)
● Lighting for Automatic Teller Machines as prepared by Illuminating Engineering Society of North America (1997).
1500 mm
(59.06 in.)
1000 mm
(39.37 in.)
B006-6453-B000 31
Personas M Series 76 ATM Site Preparation
Internal Space Constraint for Fitting a Third-Party Video Camera
The ATM can be ordered with a video camera in either PAL or NTSC format. However, if a camera is not configured and a third party video camera is to be installed, there is a space constraint to consider. The following illustration shows the space constraint dimensions.
A list of cameras that will fit within this space constraint can be found in the ATMs Feature Descriptions (B006-6451) book.
72 mm
(2.83 in.)
24 mm
(0.94 in.)
190 mm
(7.48 in.)
100 mm
(3.94 in.)
67 mm
(2.64 in.)
18 mm
(0.71 in.)
10 mm
(0.39 in.)35 mm
(1.38 in.)
CameraFront
32 B006-6453-B000
To help NCR maintain the quality of their publications, send comments on the accuracy, clarity, usability, navigation, organization, and value of this book.
Address correspondence to:
Surface mail address:
NCR Financial Solutions Group Ltd
Information Solutions
Kingsway West
Dundee
Scotland
DD2 3XX
Email address: