NEW BUILDINGS FOR LEASE
6513 EAST 46TH STREET, TULSA, OK 74145
Area Map
•2,100 SF Space Available •500SFOfficeand1600SFWarehouse
•18’EaveHeight
•12’x14’OverheadDoors
•ClearSpan(nocolumns)
•IL(IndustrialLight)ZoningallowsmanyCommercialandIndustrialuses
•46thStreetfrontagewithtrafficlightaccesstoSheridanRoad,MemorialRoadand41stStreet
LAKEYAHOLA
LAKESAHOMA
Arkansas
Arkansas
River
River
River
Verdigris
SKIATOOKLAKE
TULS
A
COU
NTY
WAG
ONER
C
OUNT
YTU
LSA
C
OUNT
YW
AGON
ER
COU
NTY
TULS
A
COU
NTY
CREE
K
COU
NTY
TULSA COUNTYCREEK COUNTY
TULS
A
COU
NTY
ROGE
RS
COU
NTY
ROGERS CO.WAGONER CO.
TULS
A
COU
NTY
OSAG
E
COU
NTY
TULSA ZOO
ORALROBERTS UNIV.
UNIV. OFTULSA
THOMASGILCREASE MUSEUM
TULSA STATEFAIRGROUNDS
EXPOSQUARE
SKELLYSTADIUM
PHILBROOK MUSEUM OF ART
Woodward Park
GARDEN CTR.
MABEE CTR.
Whiteside Park
HicksPark
Mohawk Park
LaFortune Park
McClure Park
O Brine Park
ReedPark
TurkeyMountain Park
Crawford Park
New Block Park
BARTLETTMEM. HOSP.
+
BROKEN ARROW MED. CTR. +
ST. FRANCIS HOSP.
+
ST. JOHN MED. CTR.+
HILLCREST MED. CTR.
+
OU-OSUTULSA
W. Country Rd.W. C. Rogers Blvd.
BIXBY
SAPULPA
SPRINGSSAND
BROKENARROW
JENKS
SKIATOOK
OWASSO
COLLINSVILLE
GLENPOOL
SPERRY
CATOOSA
LEONARD
BOWDEN
MARGLO
OAK-HURST
KIEFER
FAIR OAKS
VERDIGRIS
KEETONVILLE
TURLEY
ONETA
NEWTULSA
.dR atenO
diMaw
y
.dR
.dR snavE
nnyLenaL
iL ytnuoCne
Rd
.
.evA .E ht902
185th
9thSt
.
St.
lP ts1.
iaMn
0 2 4 6 M I LES1 3 5
TULSAAND VICINITY
Pine St.
ApacheMohawk
Blvd.
St.
Admiral Pl.
Newton
21st St. S.
41st St. S.
51st St. S.
61st St.
71st St.
81st St.Land Rd.
Rd.
Hilton
DeweyAve.
Ave.
Teel Rd. Main
S
t.Hi
ckor
y
St.
Miss
ion
Line Ave.
Taft
101st St. S.
141st St. S.
126th St. S.
131st St. S.
151st St. S.151st St. S. Indiana 151st St. S.
161st St. S.161st St. S. 161st St. S.
171st St. S.171st St. S. 171st St. S.
181st St. S.
121st St. S.
Delaware
Riverside
Ave.
111th St. S.
91st St.86st St.
Main St.
Saho
maLa
ke
Rd.
Edison St.
Charles Page Blvd.Springs
Sand
Creek
Overlook
Cree
k
McKi
nley
Rd.
Willo
w
Rd.
Rd.
Dr.Rd.
Shell
10th St.
trop
riA
Morrow Rd.
Avery Dr.
Dr.
Blvd.
(toll)
South
west
South
west
Blvd
.
Skylane
11th St. S.
Chero
kee
RollinsSwitch
Tiger Rd.
St. N.
St. N.
St. N.
St. N.
St. N.
St. N. 12th
2nd
Main St.
W. 144th St. N.
W. 134th St. N.
St. N.
St. N.
St. N.
St. N.
St. N.
St. N. Broadway
St. N.
36th
46th
56th
66th
76th
86th
96th
106th
116th
126th
136th
146th
156th
21st St. S.
31st St. S.31st
41st St. S.
51st St. S.
61st St. S.
71st St. S.
91st St. S.
Jasper
Yazzo
Tucson
Florence
New Orleans
Washington
Houston
Kenosha
MUSKOGEE
CREEK
CREEK
TURN
ER
OKM
ULG
EEBE
ENIL-
E
KEYSTONE
KING
SKELLY
JR.
DRIVE
BROKEN
ARROW
EXPWY.
MA
RTIN
EXPWY.
EXPWY.
EXPWY.
GILCREASE
LUTH
ER
PXE.Y
W
CHE
EEKOR
PXEW
Y.
YELLAV
NIM
GO
TURNPIKETURNPIKE
TURN
PIKE
(toll) (toll)
TURN
PIKE
Albany
81st St. S.
Ave.
Ave.
W.
Ave
.
Ave.
Ave.
Ave.
Ave.
Ave.
N. 68
th W
.
N. 60
th W
.
Cinc
innati
Ave
.
Lomb
ard
Ln.
Lena
paw
Ave.
Rd.
Rd.
Main
Rd.
Dr.
Ave.
Lewi
s
Peor
ia
Union
A
ve.
Lewi
s
Peor
iaPe
oria
Harva
rd
Yale
Sher
idan
Memo
rial
Ming
o
Garn
ettGa
rnett
Olive
Aspe
n
Elm
Elwo
od
Elm
Ave.
Ave.
Ave.
Ave.
Ave.
Ave.
Rd.
Dr.
Rd.
Rd.
Rd.
Ave.
Ave. Pl.
St.
33rd
W.
Ave.
129th
E.
Ave.
145th
E.
Ave.
177th
E.
Ave.
193r
d E.
Ave
.
225th
E.
Ave.
257th
E.
Ave.
209th
E. A
ve.
161s
t E.
Ave.
241s
t E.
Ave.
145th
W.
Ave. 129th
W.
Ave.
Ave
.11
3th W
.
49th
W.
Ave.
97th
W.
Ave
.
65th
W.
Ave.
Riverside
Dr.
rD.
Osag
eUn
ion
Peor
ia
Lewi
s
Memo
rial
Ming
o
Garn
ett
Yale
Sher
idan
Harva
rd
Muse
um
Rd.
Gilcr
ease
33rd
Cinc
innati
169
169
169
51
97
97
51
51
51
67
66
33
117
166
117A
51
20
20
167
66
11
11
64
412412
412
75
75ALT
75ALT
75ALT
TULSA
JONES
81st ST.
HARVEYYOUNG
WILL
ROGERS
T
URNPIKE
INTERNATIONALAIRPORT
SKIATOOK AIRPORT
AIRPORT
AIRPORT
AIRPORT
AIRPORT
POUGEMUNICIPAL
11
75
67
(toll)
SYSTEM
NAVI-KERR
PORTOF
CATOOSA
LAN
McCLEL
GATION
266
266
1D
3B
215
2
221
232
226
230
235
227
12A 13A15
240
229
223
1B 226A
228
6B 8
11 7 10
14
236 238 9
12B
TULS
A
COU
NTY
ROGE
RS
COU
NTY
N
2020
44
44
44
44
244244
244
44
75
64
64
75
64
75
64
64
* Map courtesy of Oklahoma Department of Transportation
©2019EquitasRealtyAdvisors,LLC
The information contained herein is believed to be accurate but is not guaranteed as to accuracy and may change or be updated without notice.
5801 East 41st Street | Suite 101 | Tulsa, Oklahoma 74135(918) 280-9900 | Fax (918) 280-9902
EquitasRealty.com
Contact: Marco Placencia, CCIM, SIOROffice(918)280-9900|Cell(918)629-5091|Fax(918)[email protected]
46thStreet
SheridanRoad
SITE
Aerial
→N
SitePlan
→N
2,100SquareFeet
7,700 SF(Divisible)
Harry K. BjornbergArchitect
4853 South Sheridan Road, Suite 612Tulsa, Oklahoma 74037
Office / Warehouse46th Street and Sheridan RoadTulsa, Oklahoma 74145
Owner
Prestige Trading Company2850 East 101st StreetTulsa, Oklahoma 74137918-299-0396
Stamp
Revisions
a
A-010
Site Plan
SITE PLANSCA;E: 1/16"= 1'-0"
1
2
A F J
20'-0"6" 6"(OUT TO OUT GIRT)
110'-0"(OUT TO OUT GIRT)
271.20'271'-2 1/2"
10'-0"6"
10'-0
"6"
70'-0
"6"
5'-0
"20
'-0"
182'
-1 1
/4"
182.
10'
12'-0
" 5' U/E
5' U/E
CL E
46t
h ST
SO
UTH
30'-0"
9'-0" 9'-0"
FACE TO FACE BRICKPROPERTY LINE TO CENTERLINE OF STREET
FACE OF BRICK TO PLFACE OF BRICKTO PROPERTY LINE
BUILDING 1 BUILDING 2
NORTH
BOLLARD DETAIL ADA PAVEMENT SYMBOL ADA PARKING SIGNSCALE: 1/2"=1'-0" NO SCALE SCALE: 1/2"=1'-0"
1'-0
"2'
-0"
3'-0
"
1'-6"
8" 8"
6'-0
" 5'-0
"
6" ROUND GALVANIZEDSTANDARD STEEL PIPE(MIN WALL THK 0.188)
18" X 36" POST HOLEFILLED WITH CONCRETE
1/2" EXPANSION FILLERAT JOINT TO CONCRETE
3'-1"
2'-10"
PAINTED STRIPING GENERAL NOTES
1. PAVEMENT MARKINGS ONECOAT OF CHLORINATED RUBBERPAINT, WHITE OR YELLOW ASSELECTED BY THE OWNER
2. HANDICAP PARKING LOGO, ONECOAT OF CHLORINATED RUBBERPAINT. BLUE FIELD WITH WHITEINTERNATIONAL SYMBOL OFACCESSIBILITY.
3. PAINTED ISLANDS AND HANDICAPPASSAGEWAY AISLES, 6" BORDERWITH 4" 45 DEGREE DIAGONAL STRIPES.
4. PARKING STRIPING IS TO BE 20' LONGAND 4" WIDE.
5. HANDICAP PARKING SIGN, ADA APPROVED SIGN DESIGNATING"VAN ACCESSIBLE" SPACE.
5'-0
"2'
-4"
ADA APPROVED SIGNDESIGNATING VAN ACCESSIBLEPARKING SPACE
12" ROUND x 24" DEEP POST HOLE, FILLED WITH CONCRETEIMBED SIGN POST 18"
A-1
A-3 A-4 A-5
A-5
20'-0 1/2"8'-11 1/2" 8'-0" 8'-11 1/2" 31'-5 1/2"36'-0"4 EQUAL SPACES
63'-0"7 EQUAL SPACES
80'-0"
D
49'-2 1/2"
75'-0" (CL STREET TO BUILDING SETBACK)
17'-0 1/2" 13'-10"
Structural Engineer
O.J.C.Co.Otis J Courtright, P.E.5579 S. Lewis AveTulsa, Ok 74105918-747-8091
Civil Engineers
Select Design20 E Dawes Ave,Bixby, Ok 74008918-798-8356
Engineered by DesignPO Box 15567,Del City, Ok 731559816-809-8253
VARIES VARIES17'-2 1/2" 8'-0"
MO
TORC
YCLE
PARK
ING
MO
TORC
YCLE
PARK
ING
A-3
A-4
75'-0
" BU
ILDI
NG
LIN
E
SIDEWALK DETAILSCALE: 1"=1'-0"
A-2
4'-0"
3'-6" 3"
6"
2"
SCALE: 1/2" = 1'-0"
4"
3" 4" THICK x 4' WIDE 3500 psiAIR-ENTRAINED CONCRETESIDEWALK REINFORCED WITH WOVEN WIRE MESH. EASE EDGES,FINISH TO BE 3" TROWELED BORDERWITH ROUGH BROOM FINISH.
2" SAND BASE (OPTIONAL)
COMPACED SUB-GRADE
STANDARD SIDEWALKRAMP. CONSTRUCTACCORDING TO CITYOF TULSA STANDARD#790
4'-0" WIDE CONCRETESIDEWALK, REFER TO A2-A010
1 REDUCED THE AREA OF BUILDING 1ADDED SIDEWALK
4'-0" HIGH FENCE
PROPOSED FIREHYDRANT
91'-6" TO CORNER
356'
55'-0" TO GATE
217'-6" TO CORNER
36'-0
"40
0' E
ND
OF
HOSE
400' END OF HOSE
261'-0" TO CORNER
ADDED FIRE HYDRANT AND HOSE LENGTH
LEASED
Harry K. BjornbergArchitect
4853 South Sheridan Road, Suite 612Tulsa, Oklahoma 74037
Office / Warehouse46th Street and Sheridan RoadTulsa, Oklahoma 74145
Owner
Prestige Trading Company2850 East 101st StreetTulsa, Oklahoma 74137918-299-0396
Stamp
Revisions
Floor Plan Bldg 1
A-100FLOOR PLAN - BUILDING 1SCALE: 1/8"=1'-0" NORTH
OFFICE FLOOR PLANSCALE: 1/4"=1'-0"A-1 A-2
ELEVATION - COFFEE BARSCALE: 1/2"=1'-0"A-3
9'-0
"
2'-1
0"2'
-2"
2'-6
"1'
-6"
4'-9 1/2"
CABINET WORK IS TOCOMPLY WITH AWI CUSTOM GRADE STANDARDS
WALL CABINET WITH 2 ADJUSTIBLE SHELVES
SINK
4" BACKSPLASHMATERIAL TO MATCHCOUNTERTOP
UTILITY DRAWER
BASE CABINET WITH 1 ADJUSTIBLE SHELF
4" RUBBER BASE
ACCESSORY MOUNTING DIMENSIONS
ACCESSORY SCHEDULE
A 42" GRABBAR #832
B 36" GRABBAR #832
C 18" GRABBAR #832
D TISSUE DISPENSER #5263 16"H x 6"W x 4"D
E NAPKIN DISPOSAL #4722-15 15"H x 11"W x 4"D
F MIRROR #780-1830 18"W x 30" H
G SOAP DISPENSER #6562-13 8"H x 5"W x 3"D
H TOWEL DISPENSER #2493 16"H x 11"W x x 9"D
TOILET ACCESSORIES SHOWN ARE BY BRADLEY.FINAL SELECTIONS TO BE MADE BY THE OWNER
A B C D E F G H I
I FIRE EXTINGUISHER 5# TYPE ABC
33"
33" 39
"
24"
33"
38" 38"
38"
48"
12" 6"
39"
30"
NOT USED NOT USED
Civil Engineers
Select Design20 E Dawes Ave,Bixby, Ok 74008918-798-8356
Engineered by DesignPO Box 15567,Del City, Ok 731559816-809-8253
Structural Engineer
O.J.C.Co.Otis J Courtright, P.E.5579 S. Lewis AveTulsa, Ok 74105918-747-8091
Date: 4/26/2018
80'-0"
25'-0" 25'-0" 30'-0"
10'-0" 12'-0" 12'-0" 10'-0" 6"2'-5"1'-0"4'-0"7'-0"1'-0"6"
70'-0
"
23'-4
"23
'-4"
23'-4
"
LINER PANEL TO FIRST GIRTTYPICAL AT NORTH, SOUTH ANDEAST WALLS. WEST WALL TO HAVE LINER PANEL AT WAREHOUSESPACE ONLY
END
WAL
L CO
LUM
NLO
CATI
ON
S M
AY V
ARY.
REFE
R TO
BLD
G M
FGRS
EREC
TIO
N D
RAW
INGS
OU
T TO
OU
T FA
CE O
F ST
EEL
A B C D
E
E
C
D
COFFEE BARRE A3-A100
35'-1
0 1/
2"
5"7'
-2 1
/2"
10'-0
"7'
-2 1
/2"
5"5"
9'-9
1/2
" RECEPTION
TOILET
TOILET
OFFICE
COFFEE
FEX
3'-1" 10'-0"
8" 1 1/2" 5'-117'-3" 5" 5"
14'-9 1/2"
8" 1'-0 1/2" 5"
5"
BHF
ACD
I
25'-0"
6"
25'-0" 30'-0"
80'-0" 6"OUT TO OUT FACE OF STEEL
50'-0"
3"11"
70'-0
"
11"
9 1/
4"
48'-10"
2'-9"
83'-11 3/4"
68'-3
3/4
"
2 248.83 + / 2 = 83.97'
SEPARATION REQUIRED = 41.98' ~ 41'-11 3/4"
4'-1" 42'-0"
WALL ASSEMBLY8" GIRT + 2 1/2" STUD+ 1/2" GB = 11"
FUTURE DEMISING PARTITION(ASSUME 6")
OFFICE
SUITE 1
DIAGONAL RULE DIAGRAMSCALE: 1/16"=1'-0"A-4
NOTE: THE OWNERS OBJECTIVE IS TO LEASE BUILDING 1 AS A SINGLE TENANTBUILDING. THE DIAGONAL RULEDIAGRAM IS SHOWN IN THE EVENT ITLEASES AS A 2 TENANT BUILDING
TENANT SEPARATIONONLY IF THE BUILDINGHAS 2 TENANTS. WALL IS SHOWN AS AN ILLUSTRATIONFOR COMPLIANCE WITH THEDIAGONAL RULE ONLY AND IS NOT PART OF THIS APPLICATION.
2'-1" 12'-11" 3'-6" 2'-1"
1 REDUCED BUILDING TO 80'-0"ADDED DIAGONAL RULE DIAGRAMREVISED DIMENSIONS
6/24/18
4'-1" TO CL OFDOOR
63.1
42'-0" PROVIDED
WINDOW TYPE C WINDOW TYPE A
1 3 1 3 1
Harry K. BjornbergArchitect
4853 South Sheridan Road, Suite 612Tulsa, Oklahoma 74037
Office / Warehouse46th Street and Sheridan RoadTulsa, Oklahoma 74145
Owner
Prestige Trading Company2850 East 101st StreetTulsa, Oklahoma 74137918-299-0396
Stamp
Revisions
a
A-101
FLOOR PLAN BUILDING 2
FLOOR PLAN - BUILDING 2SCALE: 1/8"=1'-0" NORTH
12
F G H I J
110'-0"OUT TO OUT FACE OF STEEL
30'-0" 25'-0" 25'-0" 30'-0"
6"
12'-0" 10'-0" 7'-0" 12'-0" 12'-0" 7'-0" 10'-0" 12'-0"
6"
12'-0"
CJ
30'-0"25'-0"25'-0"30'-0"
12'-0
CJ
110'-0"
12'-0
"12
'-0"
23'-0
"23
'-0"
6"6"
CJ
CJ
CJ
CJ CJCJ
CJ
CJ
CJ
A-1
23'-4
"23
'-4"
23'-4
"EN
D W
ALL
COLU
MN
LO
CATI
ON
SM
AY V
ARY.
CO
ORD
INAT
E W
ITH
BLDG
MFG
R'S
EREC
TIO
N D
WGS
1' S
LOPE
UP
TO 3
/4"
1'-2"DIMENSION MAY VARY. COORDINATEWITH DOOR MANUFACTURER
A-2 OVERHEAD DOOR SILL DETAILSCALE: 3" = 1'-0"
8"
5 3/
16"
4 1/2"
1/2"
A-3 OVERHEAD DOOR JAMBSCALE: 3" = 1'-0"
A-4 STOREFRONT JAMBSCALE: 3" = 1'-0"
2" 1/4" SHIM - SEAL BOTH SIDES
1'-2
"
2 1/
2"4
1/2"
7"1
1/2"
2 1/2" 4 1/2" 7" 1 1/2"
1'-2"
2"1/
4" S
HIM
- SE
AL B
OTH
SID
ES
A-5 STOREFRONT HEADSCALE: 3" = 1'-0"
BRICK VENEER- SOLDIER COURSEABOVE WINDOW
PROVIDE GALVANIZED TIESAT 16" OC EACH WAY
THRU-WALL FLASHING WITHWEEPS AT 24-32" OC
PANEL CLOSURE
5/8" GYP BOARD ON 7/8" FURRINGCHANNELS. PROVIDE METAL CORNERBEADS AND CASING BEADS
ALUMINUM FRAME
SEALANT
BRICK VENEER
METAL WALL PANELNEOPRENE PANEL CLOSURE
ALUMINUM FRAME
5/8" GYP BD ON FURRINGCHANNELS
METAL WALL PANELTRIM
8" CEE
CHAIN OPERATEDROLLING SERVICE DOOR
DOOR TRACK ASSEMBLYMAY VARY. VERIFY SIZE OFBLOCKOUT
METAL WALL PANEL
DOOR TRACK ASSEMBLY
NOTCH SLAB AT DOORBOTTOM. COORDINATE SIZEWITH DOOR MANUFACTURER
3'-1" 2'-0" 2'-11" 2'-11" 2'-0" 3'-1"2'-0" 2'-0" 2'-0" 2'-0" 2'-0" 2'-0"
B A A B B A A B
Civil Engineers
Select Design20 E Dawes Ave,Bixby, Ok 74008918-798-8356
Engineered by DesignPO Box 15567,Del City, Ok 731559816-809-8253
Structural Engineer
O.J.C.Co.Otis J Courtright, P.E.5579 S. Lewis AveTulsa, Ok 74105918-747-8091
LINER PANEL TO FIRST GIRT ATNORTH, SOUTH AND EAST WALLSAND AT WAREHOUSE SPACE ONWEST WALL
Date: 4/26/2018
UNIT 3 UNIT 4 UNIT 5 UNIT 6
LEASED3,500 SF
2,100 SF
70’
80’
110’
70’
7,700 SF
Possible division line
35'-1
0 1/
2"
5"7'
-2 1
/2"
10'-0
"7'
-2 1
/2"
5"5"
9'-9
1/2
" RECEPTION
TOILET
TOILET
OFFICE
COFFEE
FEX
3'-1" 10'-0"
8" 1 1/2" 5'-117'-3" 5" 5"
14'-9 1/2"
8" 1'-0 1/2" 5"
5"
BHF
ACD
I
LEASED
OFFICE
TOILET
TOILET
COFFEE
RECEPTION
Harry K. BjornbergArchitect
4853 South Sheridan Road, Suite 612Tulsa, Oklahoma 74037
Office / Warehouse46th Street and Sheridan RoadTulsa, Oklahoma 74145
Owner
Prestige Trading Company2850 East 101st StreetTulsa, Oklahoma 74137918-299-0396
Stamp
Revisions
Floor Plan Bldg 1
A-100FLOOR PLAN - BUILDING 1SCALE: 1/8"=1'-0"NORTH
OFFICE FLOOR PLANSCALE: 1/4"=1'-0" A-1A-2
ELEVATION - COFFEE BARSCALE: 1/2"=1'-0" A-3
9'-0"
2'-10"
2'-2"
2'-6"
1'-6"
4'-9 1/2"
CABINET WORK IS TOCOMPLY WITH AWI CUSTOM GRADE STANDARDS
WALL CABINET WITH 2 ADJUSTIBLE SHELVES
SINK
4" BACKSPLASHMATERIAL TO MATCHCOUNTERTOP
UTILITY DRAWER
BASE CABINET WITH 1 ADJUSTIBLE SHELF
4" RUBBER BASE
ACCESSORY MOUNTING DIMENSIONS
ACCESSORY SCHEDULE
A42" GRABBAR#832
B36" GRABBAR#832
C18" GRABBAR#832
DTISSUE DISPENSER#526316"H x 6"W x 4"D
ENAPKIN DISPOSAL#4722-1515"H x 11"W x 4"D
FMIRROR#780-183018"W x 30" H
GSOAP DISPENSER#6562-138"H x 5"W x 3"D
HTOWEL DISPENSER#249316"H x 11"W x x 9"D
TOILET ACCESSORIES SHOWN ARE BY BRADLEY.FINAL SELECTIONS TO BE MADE BY THE OWNER
A BCD EFG HI
IFIRE EXTINGUISHER5# TYPE ABC
33"
33"39
"24"
33"
38"38
"38"
48"
12"6"
39"
30"
NOT USEDNOT USED
Civil Engineers
Select Design20 E Dawes Ave,Bixby, Ok 74008918-798-8356
Engineered by DesignPO Box 15567,Del City, Ok 731559816-809-8253
Structural Engineer
O.J.C.Co.Otis J Courtright, P.E.5579 S. Lewis AveTulsa, Ok 74105918-747-8091
Date:4/26/2018
80'-0"
25'-0"25'-0"30'-0"
10'-0"12'-0"12'-0"10'-0"6" 2'-5" 1'-0" 4'-0" 7'-0" 1'-0" 6"
70'-0"
23'-4"
23'-4"
23'-4"
LINER PANEL TO FIRST GIRTTYPICAL AT NORTH, SOUTH ANDEAST WALLS. WEST WALL TO HAVE LINER PANEL AT WAREHOUSESPACE ONLY
END WALL COLUMN
LOCATIONS MAY VARY.
REFER TO BLDG MFGRS
ERECTION DRAWINGS
OUT TO OUT FACE OF STEEL
ABCD
E
E
C
D
COFFEE BARRE A3-A100
35'-10 1/2"
5"
7'-2 1/2"
10'-0"
7'-2 1/2"
5"
5"
9'-9 1/2"RECEPTION
TOILET
TOILET
OFFICE
COFFEE
FEX
3'-1"10'-0"
8"1 1/2"5'-11 7'-3"5"5"
14'-9 1/2"
8"1'-0 1/2"5"
5"
BHF
ACD
I
25'-0"
6"
25'-0"30'-0"
80'-0"6"OUT TO OUT FACE OF STEEL
50'-0"
3" 11"
70'-0"
11"
9 1/4"
48'-10"
2'-9"
83'-11 3/4"
68'-3 3/4"
22 48.83+/2= 83.97'
SEPARATION REQUIRED = 41.98' ~ 41'-11 3/4"
4'-1"42'-0"
WALL ASSEMBLY8" GIRT + 2 1/2" STUD+ 1/2" GB = 11"
FUTURE DEMISING PARTITION(ASSUME 6")
OFFICE
SUITE 1
DIAGONAL RULE DIAGRAMSCALE: 1/16"=1'-0" A-4
NOTE: THE OWNERS OBJECTIVE IS TO LEASE BUILDING 1 AS A SINGLE TENANTBUILDING. THE DIAGONAL RULEDIAGRAM IS SHOWN IN THE EVENT ITLEASES AS A 2 TENANT BUILDING
TENANT SEPARATIONONLY IF THE BUILDINGHAS 2 TENANTS. WALL IS SHOWN AS AN ILLUSTRATIONFOR COMPLIANCE WITH THEDIAGONAL RULE ONLY AND IS NOT PART OF THIS APPLICATION.
2'-1"12'-11"3'-6"2'-1"
1REDUCED BUILDING TO 80'-0"ADDED DIAGONAL RULE DIAGRAMREVISED DIMENSIONS
6/24/18
4'-1" TO CL OFDOOR
63.1
42'-0" PROVIDED
WINDOW TYPE CWINDOW TYPE A
13131