Addr.: 1820 Yeager Ave, La Verne, CA 91750 Tel: 909 587 6030 Fax: 909 334 4010 www.ecoobuy.com
Product Family Data Sheet V1.0Page 1 of 2
E503830
LEDDimmable Chandelier
Performance Data
DIMMABLE design, being able to adjust your light brightness means you’re able to create the perfect atmosphere in your room anytime. Even at low light levels, Ecoobuy Light’s light is stable and pure.
Each bulb illuminates with a warm Amber glow, filling any space with the utilitarian ambiance reminiscent of the original tungsten filament bulbs of the mid-20th century.
BenefitsFeaturesFull Range Dimming
Energy Efficient: Up to 90% Less Energy than Standard Incandescent
No Ultraviolet - Safe For Artwork
Color Consistency
Low Heat
Durable
Long Life
Instant On To Full Brightness
Suitable For Damp Locations
Dimmable
UL Listed
FCC Compliant
RoHS Compliant
100% Mercury Free
3 Years Warranty
Soft white/Daylight
Model MOL DiameterEFM-BA10D/11D Flame tip 4.29′′ 1.38′′EFM-B10D Flame tip 3.80′′ 1.38′′
D:35mm
109mm
D:35mm
96.6mm
Note: Lamp shape conforms to ANSI C78.21-2003.Note: Designed to comply with RoHS Directive 2002/95/EC.
Dimensions
300
260
80+
80+
320°
320°
320°
40W
25W
EFM-BA10D4W
EFM-BA11D4W
EFM-B10D4W
Base Type Watt Input voltage Equivalent CRI CCT Beam angleSeries
4W
4W
E12
E12
4WE12
AC120V, 60Hz
AC120V, 60Hz
AC120V, 60Hz
75
300 80+40W75
65
2700K/5000K
2700K/5000K
2200K
5000KEfficacy(Lm/w)
5000KLumens(Lm)
Addr.: 1820 Yeager Ave, La Verne, CA 91750 Tel: 909 587 6030 Fax: 909 334 4010 www.ecoobuy.com
Product Family Data Sheet V1.0Page 2 of 2
EFM-BA10D/11D/EFM-B10D
Energy Savings
Model No.
40W Incandescent
40W Incandescent
25W Incandescent
$59
$59
$25
Energy SavingsEquivalent
★ Energy Savings based on using one bulb for 15,000 hrs rated life at 11¢/kWh
Ordering Matrix
EFM-BA10D4W
EFM-BA11D4W
EFM-B10D4W
AC120V Mains
L N
AC120V Mains
Ballast
L N
Lamp Socket
Base Type: E12
LampECOOBUY
CFL Wiring Diagram
L
N
ECOOBUY Lamp Wiring Diagram
Replacing with
L
N
CFL Lamp
Family Item Dimmable Watts
A19 D 4W
4WEFM-
CL E12
CL=ClearAM=Amber E12
BA10BA11B10
D=Dimmable
27K
27K=2700K50K=5000K
EFM-BA11D4W27KCLE26EXAMPLE:
CCT Finsh Socket Base
22K=2200K
Installation Instructions for ECOOBUY Lamp:
Ensure circuit breaker is turned off and no power is going to the fixture.
Unscrew existing lamp and recycle appropriately.
Open/Access the ballast compartment and disconnect the ballast from the AC Mains and the socket. If existing system does not have a ballast, skip to Step 6.
Connect the AC Mains to the wires leading to the socket.
To avoid the risk of electric shock, do not connect the “L” and “N” wire together.Use approved electrical insulating tape or wire caps to ensure that all the wires which were cut are well insulated or capped.
1.2.
Close ballast compartment or Junction Box.
Screw-In ECOOBUY Lamp.
After installation is completed, turn circuit breaker back on and Switch-on.
Replacing CFL Lamp Wiring Diagram for ECOOBUY Lamp
E503830
LED Filament BulbsInstallation instructions
EFM-BA11DEFM-BA10DEFM-B10D
Addr.: 1820 Yeager Ave, La Verne, CA 91750 Tel: 909 587 6030 Fax: 909 334 4010 www.ecoobuy.com
Installation Guide V1.0 Page 2 of 3
ECOOBUY INC. Installation/Retrofit Guide
Thank you for purchasing ECOOBUY luminaires and for investing in the future of eco-friendly products. By selecting ECOOBUY luminaires, you have chosen a high-quality, eco-friendly product that is designed for years of dependable performance. We stand behind our products and are confident that you will have a peace of mind knowing that it is a reliable product.
This guide explains the steps necessary to install ECOOBUY luminaires in a fixture. It is for reference only and is intended for qualified electricians or lighting technicians who are familiar with the construction and operation of the product and the hazards involved. Wiring modification for ECOOBUY luminaires installation requires knowledge of luminaire electrical systems. If not qualified, DO NOT attempt this installation – Contact a qualified electrician or a lighting technician.
Warning: Important Safety Instructions. Risk of Fire or Electric Shock. Read ALL Installation Instructions before installing ECOOBUY luminaires. DO NOT Remove Cover. No User-Serviceable Parts inside.
Warning: Before conducting any inspection, installation, maintenance, disable all power to the luminaire. ECOOBUY luminaires are designed to work with AC 120V - 277V. Ballast (if equipped) MUST be bypassed or removed from the fixture before installing the ECOOBUY luminaire. See “Wiring Diagram” on backside. Failure to follow instructions can result in a damaged product and will VOID the Warranty. It could also result in an electric shock, or fire.
Disable all power to luminaire before conducting any inspection, installation, maintenance, or removal. Failure to do so will create a hazardous and potentially fatal working environment.
For use in Dry Locations. Do not use where directly exposed to Liquid, Vapor, Rain or Weather. Non-Submergible (not water tight).
The installer must determine and verify whether the supply voltage is the same as the rated lumunaire voltage before installation. Improper voltage matching can result in performance degradation and/or physical damage. These lumunaires work on line voltage and require all Ballasts and Starters to be bypassed.
Operate in fixtures that provide the free flow of air around the luminaires. In enclosed fixtures, ensure the luminaires have enough space for heat dissipation. This will ensure lumen maintenance and extend its lifespan. When luminaires are used inside an outdoor enclosure, ensure the enclosure is waterproof and well ventilated.
in whole or part, as this
Not intended for use in emergency exit fixtures or exit lights. Besuited to use with a dimmer or remote controls.
Luminaire wiring, Ballast, or other electrical parts may be damaged during installation. Always check for loose wiring and components.
To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects.
Do not make or alter any open holes in an enclosure for wiring or electrical components during installation.
Do not block light emanating from luminairesmay cause an unsafe condition.
Installing surge/lightning protectors is highly recommended and helps to eliminate premature driver failure caused by surges and other power fluctuations.
This product can expose you to chemicals including (name of one or more chemicals),which is (are) known to the State of California to cause cancer.For more information go to WWW.P65Warnings.ca.gov
Addr.: 1820 Yeager Ave, La Verne, CA 91750 Tel: 909 587 6030 Fax: 909 334 4010 www.ecoobuy.com
Installation Guide V1.0 Page 3 of 3
Installation Instructions for ECOOBUY Lamp:
Installation/Retrofit Guide
Dimensions
Important Safety Instructions. Risk of Fire or Electric Shock. Read ALL Installation Instructions before installing ECOOBUY luminaires. No User-Serviceable Parts inside.
Thank you for purchasing ECOOBUY luminaires and for investing in the future of eco-friendly products. By selecting ECOOBUY luminaires, you have chosen a high-quality, eco-friendly product that is designed for years of dependable performance. We stand behind our products and are confident that you will have a peace of mind knowing that it is a reliable product.
This guide explains the steps necessary to install ECOOBUY luminaires in a fixture. It is for reference only and is intended for qualified electri-cians or lighting technicians who are familiar with the construction and operation of the product and the hazards involved. Wiring modification for ECOOBUY luminaires installation requires knowledge of luminaire electrical systems. If not qualified, DO NOT attempt this installation – Contact a qualified electrician or a lighting technician.
Disable all power to luminaire before conducting any inspection, installation, maintenance, or removal. Failure to do so will create a hazardous and potentially fatal working environment.
For use in Dry Locations. Do not use where directly exposed to Liquid, Vapor, Rain or Weather. Non-Submergible (not water tight).
For use with a dimmerCCT Range complies to ANSI C78.377-2008.
Thermally stable typical lumens (± 10%) .
Rated life is based on 70% lumen maintenance, and engineering testing and probability analysis.
Equivalency based on the Energy Star® Integral LED Lamp Center Beam Intensity Benchmark Tool.
Model MOL Diameter
EFM-4W 3.80" 1.38"
LampECOOBUY
CFL Wiring Diagram
L
N
ECOOBUY Lamp Wiring Diagram
Replacing with
L
N
CFL Lamp
AC120V Mains
L N
AC120V Mains
Ballast
L N
Lamp Socket
ECOOBUY Lamp Wiring Diagram
L
N
LampECOOBUY
ECOOBUY Lamp Wiring Diagram
HPS / HID Lamp
Ballast
IgnitorCapacitor
HPS/HID Wiring Diagram
Replacingwith
Replacingwith
L
N
Ballast
IgnitorCapacitor
Warning:Before conducting any inspection, installation, maintenance, disable all power to the luminaire. ECOOBUY luminaire are designed to work with AC120V.
Warning:
Ensure circuit breaker is turned off and no power is going to the fixture.
Unscrew existing lamp and recycle appropriately.
Open/Access the ballast compartment and disconnect the ballast from the AC Mains and the socket. If existing system does not have a ballast, skip to Step 6.
To avoid the risk of electric shock, do not connect the “L” and “N” wire together.
Use approved electrical insulating tape or wire caps to ensure that all the wires which were cut are well insulated or capped.
Close ballast compartment or Junction Box.
Screw-In ECOOBUY Lamp.
After installation is completed, turn circuit breaker back on and Switch-on.
Connect the AC Mains to the wires leading to the socket.
Wiring Diagram for ECOOBUY Lamp
Replacing CFL Lamp
Replacing HPS / HID Lamp
Base Type: E12
Addr.: 1820 Yeager Ave, La Verne, CA 91750 Tel: 909 587 6030 Fax: 909 334 4010 www.ecoobuy.com
Warranty V1.0 Page 1
LIMITED WARRANTY
ECOOBUY Inc. warrants to the original purchaser that all products sold will be free from defects in material and workman-ship for a period of three (3) years from the date of original purchase. Special and custom orders carry ONLY one year warrantyunless stated expressly. All returns must be approved and returned with shipping prepaid in original condition and in their original packaging.
If any product covered by this limited warranty is returned by the original purchaser and found to be defective, ECOOBUY will, at its own discretion, repair or replace the product, or reimburse the original purchaser for the purchase price. ECOOBUY will bear any freight cost that arises from shipping the replacement product back to the purchaser. If ECOOBUY chooses to replace the product, and the particular product is not available, ECOOBUY may have the discretion to replace it with a comparable product.
Warranty terms and policies are subject to change without notice.
THIS LIMITED WARRANTY SET FORTH ABOVE IS THE ONLY EXCLUSIVE WARRANTY GIVEN BY ECOOBUY WITH RESPECT TO THE PRODUCTS AND SOLE REMEDY FOR ANY AND ALL CLAIMS, AND NO OTHER WARRANTIES OR ANY KIND, WHETHER STATUTORY, ORAL, WRITTEN, EXPRESSED OR IMPLIED WARRANTIES OF MERCHANTABI-LITY OR FITNESS FOR A PARTICULAR PURPOSE SHALL APPLY. UNDER NO CIRCUMSTANCES SHALL ECOOBUY BE LIABLE FOR ANY INDIRECT, CONSEQUENTIAL OR COMPENSATORY DAMAGES, INCLUDING, WITHOUT LIMITATION, DAMAGES RESULTING FROM LOSS OF USE, PROFITS, BUSINESS OR GOODWILL.
The limited warranty may be voided due to the following conditions:
Purchaser’s continuing use of products after reporting the defect .
Purchaser fails to store, install, operate, or maintain applicable products in accordance with ECOOBUY’s operating instruction, or adhere to any of the electric codes, such as the National Electric Code (NEC), the Standards for Safety of Underwriters Laboratories (UL), or the American National Standards for the American National Standards Institute (ANSI).
Purchaser alters, repairs or has service performed on the applicable product without ECOOBUY’s prior written consent.
Damage or failure to perform arising from any abuse, misuse, abnormal use, improper power supply, power surges, use of unauthorized components, vandalism, or in the event of Force Majeure.