PASOLINK NEO & NEO/cRoadmap & Product Line Up
For Banglalink
222007NOV15 2007NOV15 NEC Confidential NEC Confidential
Equipment Menu (PASOLINK NEO)Equipment Menu (PASOLINK NEO)
Modulation256QAM
128QAM
64QAM
32QAM
16QAM
8PSK
4PSK
0 3.5 7.0 14.0 28.0 40.0 56.0 [MHz]Adjacent CH Spacing
5E1 10E1 20E1
5E1 10E1 20E1 40E1
● ● ●
● ● ● ●
100MB/48E1
STM-1
●
●
PASOLINK NEO(Standard version)
●
332007NOV15 2007NOV15 NEC Confidential NEC Confidential
1.1. Equipment Equipment MenuMenu
Interface (NEO)PDH : 5/10/20E1, 4PSK
5/10/20/32/40E1, 16QAM48E1, 32QAM1/2E3, 4PSK/16QAM
SDH : STM-1, 128QAM2xSTM-1, 128QAM/XPIC
Ethernet : 10M/20M/40Mbps, 4PSK10M/20M/40M/80Mbps, 16QAM100Mbps, 32QAM100M/50M or 75M/75Mbps, 128QAM
RF FrequencyNEO : L6/U6/7/8/10.5/11/13/15/18/23/26/28/32/38/52GHz
2x40E1=>80E12x48E1=>96E1
PDH XPIC
442007NOV15 2007NOV15 NEC Confidential NEC Confidential
PASOLINK NEO IDU MODULESPASOLINK NEO IDU MODULES
12
3
4 5
7
6
PASOLINK NEO IDU RACK AND MODULESNO.
1
2
3
3
4
4 H2960 [B] STM-1 INTFC Optical (S 1.1) SDH Main Slot
4 H2960 [C] STM-1 INTFC Optical (L 1.1) SDH Main Slot
4 H2965 [C] LAN / WS INTFC SDH Main Slot (2 Port LAN)
5 H2965 [C] LAN / WS INTFC SDH Main / Sub-Slot (WS/SC LAN)
4 H3021 GbE INTFC SDH Main Slot
5 H2960 [B] STM-1 INTFC Optical (S 1.1) SDH Sub-Slot (APS)
5 H2960 [C] STM-1 INTFC Optical (L 1.1) SDH Sub-Slot (APS)
5 H2965 [A] LAN / WS INTFC SDH Sub-Slot (WS/SC LAN)
6 H2980 [B] 16E1 E/W 2 Way DXC INTFC PDH With 2 Port LAN
5 H2965 [B] LAN / WS INTFC SDH Sub-Slot (WS)
6
6
6 H3010 E3 INTFC PDH Two E3, up to 8 WS
6 H3020 4P LAN INTFC PDH With E1s
7
CODE NO. MODULE NAME REMARKS
H2931 RACK COMMON
H2940 MODEM COMMON (1+0)
H2940 MODEM COMMON (1+1)
H3040 DC-DC CONV COMMON (1+0) (with EHG ODU)
H2960 [A] STM-1 INTFC Electrical SDH Main Slot
H2980 [A] 16E1 INTFC + 2 Port LAN PDH
H3000 48E1 INTFC PDH
H2950 CTRL COMMON
552007NOV15 2007NOV15 NEC Confidential NEC Confidential
Replaceable Interface Cards
Interface cards
Control CardModem
662007NOV15 2007NOV15 NEC Confidential NEC Confidential
Replaceable Interface Cards
1. 16E1 + 2 Port LAN
5. 1xE3/2xE3 + 2port LAN
2. 48E1
3. 4 Port LAN + 4/8E1
4. 32E1 + 2 Port LAN
6. STM-1(opt)
7. STM-1(elec)
8. 2 Port LAN or WS(E1)/LAN
9. 1 Port GbE
10. 16E1+2 Port LAN with DXC
11. Nodal (expandable)
12. Nodal (expandable: STM-1 termination)
13. VLAN (4port FE+4E1)
14. VLAN (3port FE+1port GbE+1E1)
[NEO Standard]
[VLAN][Standard Nodal]
Just released
2008,1QJust released
772007NOV15 2007NOV15 NEC Confidential NEC Confidential
32E1 & 2PORT LAN INTFC FOR PDH
80/96E1 PDH XPIC SYSTEM
882007NOV15 2007NOV15 NEC Confidential NEC Confidential
32E1 + LAN32E1 + LAN
•E1 x 32 Channels (MDR68(68pin) x 2, 75/120 ohm S/W selectable)•10/100BASE-T(X) x 2 Ports (RJ-45 x 2, Auto-Negotiation / Auto-MDI/MDIX)
System : PDH
N/AN/AO
E1 Protection (SNCP)2Way DXCTERMINAL
Transmission Capacity & Modulation
10M 20M 40M 80M 100M 156M
QPSK/16QAM 16QAM 32QAM 128QAM
O O O O O N/A
Mapping Interface Speed
MAIN SC 10M 100M 1000MRMON
O O O O N/A O N/A
VLAN
LAN Specification
.
992007NOV15 2007NOV15 NEC Confidential NEC Confidential
PDH XPIC (CCDP)PDH XPIC (CCDP)
FeaturesFeatures
Super PDH 80E1/ 16QAM in 28MHz band width96E1/ 32QAM in 28MHz band width
Good XPIF (Cross Polarize Interference Improvement Factor)
16QAM 15 dB (1dB degradation C/I 25dB<XPIF + Antenna XPD)
32QAM 18 dB (1dB degradation C/I 25dB<XPIF + Antenna XPD)
XPIC: Cross Polarization Interference Canceller CCDP:Co-Channel Dual Polarized
10102007NOV15 2007NOV15 NEC Confidential NEC Confidential
XPIC ConfigurationXPIC Configuration
Two ODUs and Dual polarized Antenna
Vertical
Horizontal Cancel and Control signals
40/48E1
28 MHz
Vertical(11-38GHz Direct Mount Antenna Available.6-10GHz feeder connection between Antenna and ODU)
Horizontal
Two IDUs 40/48E1
11112007NOV15 2007NOV15 NEC Confidential NEC Confidential
80/96E1 PDH XPIC System80/96E1 PDH XPIC System
1+0 IDU40/48E1 ODU
f1
ODUf1
1+0 IDU40/48E1
V
H
1+0 IDU40/48E1ODU
f1
ODUf1
1+0 IDU40/48E1
VH
HV
-H
-V
V
H
V
H
Cancellation
XPIC System configuration
TX SIDE RX SIDE
40E1/16QAM or 48E1/32QAM40E1/16QAM or 48E1/32QAM
28MHz
40/48E1
40/48E128MHz
40/48E1
IDU ODU
40/48E140/48E1
40/48E1
12122007NOV15 2007NOV15 NEC Confidential NEC Confidential
PDH XPIC System ParameterPDH XPIC System Parameter
System parameters are the same as normal equipment
Frequency band 6-8GHz 10-11GHz 13GHz 15GHz 18GHz 23GHz 26GHz 28GHz 32GHz 38GHzRange(GHz) 5.925-8.5 10.15-11.7 12.75-13.25 14.2-15.35 17.7-19.7 21.2-23.6 24.25-27.0 27.5-29.5 31.8-33.4 37.0-40.0Tx power(dBm)
32QAM 25 21 21 21 19 19 18 18 17 14.5 16QAM 26 21.5 22.5 22.5 22 22 20 18 17 14.5
Receiver threshold(dBm) at 10-6 BER 100M/32Q -75.5 -74.5 -74.5 -75.0 -75.0 -75.0 -74.5 -74.5 -73.0 -73.0
80M/16Q -77.0 -76.0 -76.0 -76.5 -76.5 -76.5 -76.0 -76.0 -74.5 -74.5System Gain(dB) at 10-6 BER
100M/32Q 100.5 95.5 95.5 96.0 94.0 94.0 92.5 92.5 90.0 87.5 80M/16Q 103.0 97.5 98.5 99.0 98.5 98.5 96.0 94.0 91.5 89.0
Regarding QPSK, CCDP can be applied without XPIC.
13132007NOV15 2007NOV15 NEC Confidential NEC Confidential
NEO/c
Main FeaturesMain Features
Common platform design (PDH, LAN)16E1 + 2FE INTFC Card
Bitrate Free10MB/ 20MB/ 40MB (Same Module)
Modulation Selectable 4PSK/ 16QAM
Compact size/ Low powerIDU :1+0/1+1 @ 1U without FAN , ODU : 2 LTR(13G~)
Bandwidth and Modulation Free ODUCoverage from 5E1 to 16E1 or from 10M to 40Mbps.
14142007NOV15 2007NOV15 NEC Confidential NEC Confidential
1+0 Equipment Configuration1+0 Equipment Configuration
ODU(13G-38G)
CTRL
1U
IDU Dim. :482x44x190mmvs PASO V4 : 76%vs NEO standard : 84%
IDU E1 Interface
ALM INTFC (Option)
DC -48V SC/ALM Fuse (same as V4/PASO+)
LCT
1+0 @ 1UBitrate free (5E1– 16E1)Modulation free (4PSK, 16QAM)
ODU(7G/8G)
15152007NOV15 2007NOV15 NEC Confidential NEC Confidential
1+1 Equipment Configuration1+1 Equipment Configuration
INTFC Card 16E1 INTFC only
MD UNIT (for NEO/c) CTRL Card (for NEO/c)
1U
ODU / Hybrid
IDU
IDU Dim.482x44x230mm1+0 exp / 1+1 @ 1UBitrate free (5E1– 16E1)Modulation free (4PSK, 16QAM)
same as NEO standardvs PASO V4 : 92%
16162007NOV15 2007NOV15 NEC Confidential NEC Confidential
NEO/c IDU MenuNEO/c IDU Menu
Type SystemConfig.
Capacity Modulation LAN Form
1-1 1+0 5xE1 Fix 4PSK Fix N/A
1-2 1+0 5/10/16 xE1Selectable
4PSK Fix N/A
1-3 1+0 5/10/16 xE1Selectable
4PSK/16QAMSelectable
N/A
2-1 1+1/1+0 exp.
5/10/16 xE1Selectable
4PSK Fix Up to40MB
2-2 1+1/1+0 exp.
5/10/16 xE1Selectable
4PSK/16QAMSelectable
Up to40MB
*1) e/w Alarm Interface Option
*1)
*1)
*1)
17172007NOV15 2007NOV15 NEC Confidential NEC Confidential
ODU Menu (Comparison with V4/Mx)ODU Menu (Comparison with V4/Mx)
o:released -:N/ACurrent Menu L6 U6 7 8 10 10.5 11 13 15 18 23 26 28 32 38 52
o o o o o o o o o o o o o o o o
- - o o - - - o o o o o - - o o
- - o o - - - o o o o o - - o -
New Menu- - o o - - - o o o o o - - o -NEO/c
MxNEO standard
V4
7G/8G 13G -- 38G
SUB Band :same as V4 ODU
18182007NOV15 2007NOV15 NEC Confidential NEC Confidential
Application of NEO standard/compactApplication of NEO standard/compact
NEO/cNEO/c NEO standardNEO standard5E1-16E1
4PSK/16QAM5E1-48E1 / STM-1 (XPIC)
4PSK-128QAM
Fixed Upgrade
with LAN NEO standard ODU
1+1,1+0 exp.
NEO compact
For future upgrade
without LAN
NEO standard IDU1+1,1+0 exp.
1+0 fixed
NEO compact
19192007NOV15 2007NOV15 NEC Confidential NEC Confidential
NEC’s Nodal RadioIDU Type 2Way Fixed Type 2Way Expandable Type 6Way Box Type
Max. Air Capacity 80Mbps (40E1) 100Mbps (48E1) 100Mbps (48E1)155Mbps (STM-1)310Mbps (2xSTM-1)
Interface E1 16ch 16ch / unit 32ch / card
STM-1 (opt)
STM-4 (opt)
LAN
Cooling Natural Forced (FAN) Forced (FAN)
N.A 1ch / unit 1 ~ 4ch / card
N.A N.A 1ch / card
No. of branching 2-Way / Rack 2-Way / IDU(max.8-way / 4IDU)
6-Wa y /Rack(max. 12-Way / 2Rack)
2xFE
N/A
1U
N.A 4FE + 1GbE
Redundant system of DXC N/A Available
Unit Size 1U x 4 + Fan unit 6U ~ 8U
12-Way8-Way (Max.)
RCPMCP
MODEMMODEMMODEMMODEMMODEMMODEM
CONV CONV
APAPAPAP
CONV CONVCONV CONV
P-INF
AUX/SVDXCDXC
P-INF
FAN
FAN
RCPMCP
MODEMMODEMMODEMMODEMMODEMMODEM
CONV CONV
APAPAPAP
CONV CONVCONV CONV
P-INF
AUX/SVDXCDXC
P-INF
FAN
FAN
RCPMCP
MODEMMODEMMODEMMODEMMODEMMODEM
CONV CONV
APAPAPAP
CONV CONVCONV CONV
P-INF
AUX/SVDXCDXC
P-INF
FAN
FAN6-Way2-Way
2Way Expandable Type2Way Fixed Type 6Way Box Type
20202007NOV15 2007NOV15 NEC Confidential NEC Confidential
2 Way NODAL - PDH – CROSS CONNECT
Max. 80Mbps(40E1)Air Capacity
16E1+LAN
2x8E1(D-Sub)
Dir-AA) Term DXC
D/I for A
DXC
Dir-AA) Term DXC
D/I for A
DXC
DXC
Dir-AB) 2way-Star
Dir-B
D/I for AD/I for B
Dir-A >= Dir-BDXCDXC
Dir-AB) 2way-Star
Dir-B
D/I for AD/I for B
Dir-A >= Dir-BDXC
Dir-AC) 2way-tree
Dir-B
D/I for A
Rep
Dir-A > Dir-BDXC
Dir-AC) 2way-tree
Dir-B
D/I for A
Rep
Dir-A > Dir-BDXC
Dir-AD) 2way-Rep
Dir-B Rep
Dir-A = Dir-BD/I = 0
Dir-AD) 2way-Rep
Dir-B Rep
Dir-A = Dir-BD/I = 0
2 WAY -TREETERMINAL - DXC
2 WAY -STAR 2 WAY -REPEATER
21212007NOV15 2007NOV15 NEC Confidential NEC Confidential
EQUIPMENT SETUP EQUIPMENT SETUP –– PDH XC INTFCPDH XC INTFC
Dir -ADir -BRep
DXC
Dir -ADir -BRep
DXC
Dir -A
D/I for A
DXC
Dir -A
D/I for A
DXC
TERMINAL
REPEATER
TERMINAL REPEATER
User Interface PDH E1 with LAN PDH E1 with LANRedundancy setting
(1+0) (Term) 2-way PDH
INTFC Main 16E1 2-Way/XC PKG(E/W LAN) 16E1 2-Way/XC PKG(E/W LAN)Modulation QPSK 16 QAM QPSK QPSK 16QAM 16QAM
10 10 10 10 10 10
80 80 80
TRANSMISSIONCAPACITY
20 20 20 20 20 2040 40 40 40 40 40
DIR-A DIR-B DIR-A DIR-B
1. Select PDH E1 with LAN as User Interface
2. For Redundancy Setting
Select (1+0) TERM for Terminal Configuration
Select (2-WAY PDH for Repeater Configuration
3. Interface Main: 16E1 2-Way/XC PKG (E/W LAN)
4. Interface Main: 16E1 2-Way/XC PKG (E/W LAN)
5. Select the Modulation scheme. For repeater select for DIR-A & DIR-B
6. Select the Transmission Capacity. For repeater select for DIR-A & DIR-B (Depends on the selected Modulation scheme
22222007NOV15 2007NOV15 NEC Confidential NEC Confidential
PROVISIONING PROVISIONING –– XC SETTING (TERMINAL)XC SETTING (TERMINAL)
Dir -A
Tributary LB
DXC
Dir -A
DXC
D/I for A
Select XC Function Enabled to Map the DIR-A and Tributary Channels as required.
To set all DIR-A channels to Tributary, one-to-one click this button
Click and select DIR-A to assign the radio channels to Tributary Channels
Click and select Tributary to assign the Tributary channels to radio Channels
Click and select for each radio channel the mapping Tributary or space (No Assignment)
Click and select the Tributary Channel number to be assigned to the radio channel
Click the CH MAP button to see the connection graphically
23232007NOV15 2007NOV15 NEC Confidential NEC Confidential
Mapping displayMapping display
Assign the channel mapping. Indicate the mapping
CH MAP : Graphical display of the channel mapping
LAN ASSIGNMENT NOT SHOWN HERE
Indicate the mapping for each type of channel Dir-A, DIR-B and Tributary
24242007NOV15 2007NOV15 NEC Confidential NEC Confidential
PROVISIONING PROVISIONING –– XC SETTING (REPEATER)XC SETTING (REPEATER)
Show the connection between the radio channels and the tributary channels
Dir -ADir -BRep
DXC
Dir -ADir -BRep
DXC
Click this button to set all DIR-A channels to Tributary Channels
Click this button to set all DIR-A channels to DIR-B Channels (No drop & Insert)
25252007NOV15 2007NOV15 NEC Confidential NEC Confidential
22--Way Expandable Type (4x2Way Expandable Type (4x2--Way)Way)
• Digital Cross Connect function
• Max. 8-Way Configuration using 4 IDUs
• Max. 48E1 (100Mbps) Air Capacity
• Air Compatibility with STD PDH menu
• STM-1 Termination
• FAN Unit is necessary
FAN UNIT
26262007NOV15 2007NOV15 NEC Confidential NEC Confidential
Structure of Structure of 6 Way Box 6 Way Box Nodal Radio EquipmentNodal Radio Equipment
AP (Interface Card)
MODEM
CS(DXC)
OAM&P
RA (Radio Access Card)
AUX
P_INF (Power Supply Card)FAN
AUX : Auxiliary interface CardOAM&P : Operation, Administration,
Maintenance and Provisioning
27272007NOV15 2007NOV15 NEC Confidential NEC Confidential
Interface Card lineInterface Card line--upup
Interface Card line-up is as follows.Card Function
32xE1 Interface 32x E1, (2x MDR 68pin)
STM-4 (OPT) Interface 1x STM-4 (SFP)
PDH Fast Ethernet Interface 6x FE (for PDH Radio)
SDH Fast Ethernet Interface 6x FE (for SDH Radio)
SDH Giga-bit Ethernet Interface 2x GbE (for SDH Radio)
STM-1 (OPT/ELE) Interface 4x STM-1 (SFP)
28282007NOV15 2007NOV15 NEC Confidential NEC Confidential
Combination of Interface CardCombination of Interface CardDifferent interface cards are mountable in a same box.
Interface Card
(32E1 INTFC)
(FE INTFC)
(STM-1 ELE)
(STM-1 OPT)
FAIL
PWR
1000 BASE PORT1
ACT2ACT1
LINK2LINK1
PORT1PORT4 PORT3 PORT2 OUT IN1000BASE PORT2
OUT IN
FAIL
PWR
PORT1PORT6 PORT5 PORT4 PORT3 PORT2
FAIL
PWR
ONLINEOUT INSTM- 1 CH4
14 23
OUT INSTM-1 CH3
OUT INSTM- 1/ 4 CH2
OUT INSTM- 1/ 4 CH1
FAIL
PWR
2M IN/ OUT- A 2M IN/ OUT- B
FAIL
PWR
ONLINEOUT INSTM- 1 CH4
14 23
OUT INSTM-1 CH3
OUT INSTM- 1/ 4 CH2
OUT INSTM- 1/ 4 CH1
(GbE INTFC) (STM-4)
FAIL
PWR
ONLINEOUT INSTM- 1 CH4
14 23
OUT INSTM-1 CH3
OUT INSTM- 1/ 4 CH2
OUT INSTM- 1/ 4 CH1
Five interface card slots
UpgradeableScalable
Low initial cost
29292007NOV15 2007NOV15 NEC Confidential NEC Confidential
4x STM-1
NxE1 NxE1
NxE1
NxE1
NxE1
NxE1NxE1NxE1
XPIC4x STM-1
NEO Nodal
N-way solution for high density site
NEO Standard
NxE1NxE1
NxE1
NxE1
NxE1
NxE1
NxE1
NxE1
BSC
NEO Standard
Network Application (1)Network Application (1)
- NEO Nodal and NEO Standard can be connected by air.- Different frequencies, capacities, and modulation types are supported in the same box.
30302007NOV15 2007NOV15 NEC Confidential NEC Confidential
STM-4
NxE1
NxE1
NxE1
NxE1
STM-1STM-1
NEO Nodal
N-Way solution for high capacity site
NEO Standard
NxE1STM-1
NxE1
NxE1
NxE1
STM-1
STM-4
(optical cable)
BSC
Network Application (2)Network Application (2)
NEO Standard
- Planned Support for STM-4 Interface.- Connection to the core network (BSC, etc.) by Radio, Optical or Ethernet.
31312007NOV15 2007NOV15 NEC Confidential NEC Confidential
Nodal Radio Road Map MenuNodal Radio Road Map Menu
Currently AvailableCurrently Available2 Way Fixed Type2 Way Fixed Type
2 Way Expandable Type (8 Way)2 Way Expandable Type (8 Way)
ReleaseRelease--1 1 1Q 2008 1Q 2008 6-Way RadioBaseband Interface : STM-1 (OPT/ELE), 32E1Air Capacity : STM-1, 5-48E1 (Bitrate free)DXC Function (Capacity : 1008x1008E1)1+0, 1+1 Hot Standby
ReleaseRelease--2 2 Under schedulingUnder schedulingBaseband Interface : FE(SDH), FE(PDH)CS & RA Module RedundancyAUX Interface1+1 Twin Path
32322007NOV15 2007NOV15 NEC Confidential NEC Confidential
PASOLINK NEOPASOLINK NEO
LANLAN (Ethernet)(Ethernet) FunctionFunction SummarySummary
33332007NOV15 2007NOV15 NEC Confidential NEC Confidential
LANLAN (Ethernet)(Ethernet) FunctionFunction SummarySummary
Interface Card 16E1+2LAN INTFC 4LAN +8E1 INTFC E3+2LAN INTFC LAN/WSINTFC 2Way DXC (16E1+2LAN)
System PDH(10~80MB) PDH(80MB) PDH(40~80MB) SDH(156MB) PDH(10~80MB)
10Base-T100Base-TX
2 (RJ-45)
~80Mbps
N.A
~256Kbps
1548 bytes
1024, 5min
512Kbit
RMON Supported Supported Supported Supported Supported Supported
SDH(156MB)
Address Table / Aging 1024, 5min 1024, 5min 1024, 5min 1024, 5min N.A
Frame Buffer 512Kbit 512Kbit 512Kbit 512Kbit 336Kbit
10Base-T100Base-TX
2 (RJ-45)
Main N.A
WS N.A N.A ~16Mbps 2Mbps N.A
SC ~256Kbps N.A ~256Kbps ~256Kbps N.A
1548 bytes
GbEINTFC
Interface 10Base-T100Base-TX
10Base-T100Base-TX
10Base-T100Base-TX
1000Base-T1000Base-SX1000Base-LX
1 (SFP/RJ-45)
150Mbps
9600 bytes
Number of LAN Port 2 (RJ-45) 4 (RJ-45) 2 (RJ-45)
~80Mbps ~100Mbps 150Mbps
Maximum Frame Length 1548 bytes 1548 bytes 1548 bytes
Maximum Throughput
*1
*2*2 *2*2 *2
N.A: Not Available*1 1000BASE-LX/SX and 1000BASE-T are exclusive use. (It is not possible to use at the same time.)*2 When VLAN is enabled, maximum frame length is limited to 1522 bytes.
When VLAN is disabled, ISL transparency transmitting is supported.
34342007NOV15 2007NOV15 NEC Confidential NEC Confidential
Transmission mode Transmission mode (PDH)(PDH)
1. Separated mode
Each Port is completely independent.
2. Shared mode
All Port are transmitted by using the same band.
3. Shared mode + Switching Function
PORT 1
PORT 2
PORT 1
PORT 2
A A
B
A B
B
BA
B
A
ST -1 ST -2
Signals can pass between local ports too.
35352007NOV15 2007NOV15 NEC Confidential NEC Confidential
Transmission mode Transmission mode (SDH) (SDH)
1. 2Port LAN
A : B a. 75M : 75Mb. 100M : 50Mc. 100M : disabled. Best Effort
PORT1
PORT2
PORT1
PORT2
A A
B
A
B
ST- 1 ST- 2
150Mbps B
Each Port is completely independent.
2. GbE LAN
GbE INTFC supports only one port.
36362007NOV15 2007NOV15 NEC Confidential NEC Confidential
Application example Application example (4port LAN)(4port LAN)
Guaranteed bandwidth service(P1-4 Separated mode)
4 ports are completely separated and guaranteed maximum throughput for each port.
Data distribution service 1: 4 asymmetrical network, like as connecting data center and terminals.(P1-4 Shared mode)
37372007NOV15 2007NOV15 NEC Confidential NEC Confidential
Adaptive Modulation Radio
Two types of AMR (Hit type and Hitless type) are under development.
Even hit type, the interruption time is small (<300msec), then there is no problem of using it to the current mobile network.
The system from 48E1(32QAM) to 20E1(QPSK)or from 40E1(16QAM) to 20E1(QPSK) can be selected.System gain is improved 13.5dB or 9dB by changing the system above.
Combination of E1 and Ethernet signal transmission is available.
The normal ODU can be used for this application.
Under Trial
System gain Comparison (BER=10-3)
48E1/32QAM40E1(16QAM) 20E1(QPSK) 95.5dB 100dB 109dB
38382007NOV15 2007NOV15 NEC Confidential NEC Confidential
Dynamic Modulation Radio
28MHzQPSK20E1(40Mbps)
Normal conditionCritical condition
28MHz32QAM48E1(100Mbps)
28MHz16QAM40E1(80Mbps)
or
Modulation scheme and Traffic capacity are automatically selected in accordance with the path condition.
or LAN
or LAN
Example
IDU Standard
Additional capacity in clear sky conditionby using high density modulation(16QAM/32QAM) in the same channel bandwidth.
39392007NOV15 2007NOV15 NEC Confidential NEC Confidential
Dynamic Modulation Radio• Dynamic Modulation Radio (DMR)
There is interruption when switchingInterruption time : 400msec (NEC’s specification)
300msec (typical value)
- Dynamic Modulation Radio with 48E1 Interface
40402007NOV15 2007NOV15 NEC Confidential NEC Confidential
Supported Modulation Schemes
Sunny conditionRainy condition
bandwidth
Menu 1: 7MHz
10E1 / 16QAM5E1 / QPSK
Menu 2: 14MHz
20E1 / 16QAM10E1 / QPSK
Menu 3: 28MHz
40E1 / 16QAM20E1 / QPSK
Menu 4: 28MHz
48E1 / 32QAM20E1 / QPSK
41412007NOV15 2007NOV15 NEC Confidential NEC Confidential
SwitchSwitch--over process Exampleover process Example
(48E1/32QAM (48E1/32QAM 20E1/QPSK20E1/QPSK, 28MHz band, 28MHz band))
Switch from32QAM to QPSK
Switch fromQPSK to 32QAM
32QAM QPSK 32QAM
-73dBm(48E1/32QBER=10-9)
-65dBm
-85dBm(20E1/QPSKBER=10-3)
RSL
-76.5dBm(48E1/32QBER=10-3)
Tx power difference(5 dB)
Outage Area(48E1/32QAM)
-70dBm
-60dBm
48E1 20E1 48E1
Operation threshold
Outage Area(20E1/QPSK)
Recovery threshold
43432007NOV15 2007NOV15 NEC Confidential NEC Confidential
QoS Support (802.1p COS)
Data with high priority is transmitted
IDU
GbEe.g. STM-1/155Mbps
Queuing
Switch/Router
VL2VL3VL1… VL1
VL2VL3
VLAN with high priority is stored in high priority queue buffer.
VL1VL1
..
VLANtagging
Vo IP
Data-P2
Data-P1
IDU
VL1VL2VL3
Priority
high
Low VL4
VLANtagging
Vo IP
Data-P2
Data-P1
* COS : Class of Service* TOS : Type of Service
Traffic ShapingVLAN CARD
44442007NOV15 2007NOV15 NEC Confidential NEC Confidential
Tag-based VLANVLAN CARD
- Tag-based VLAN (802.1Q VLAN)The connection between each clients can be set-up by using VLAN ID.
Connection Example
45452007NOV15 2007NOV15 NEC Confidential NEC Confidential
IDUXPIC ODU
STM-2/128QAM(310MB)
ODUIDUXPIC
28MHz
STM-1
56MHz
STM-2(310MB
)
56MHz28MHz
STM-1
STM-1
V
H
STM-2(310MB
)STM-2(310MB
)
STM-1 2xSTM-1/XPIC STM-2 / Carrier 2xSTM-2 / XPIC
High Capacity Radio
STM-2/128QAM(310MB)
IDU ODUSTM-1
STM-1
STM-1
STM-1
STM-1
STM-1
NEO Enhanced
One Box (IDU)
STM-2/128QAM(310MB)
46462007NOV15 2007NOV15 NEC Confidential NEC Confidential
IDUXPIC
STM-1ODU
STM-2/128QAM(310MB)
ODU
IDUXPICSTM-1 ODU
STM-1/128QAM
XPICIDU ODUSTM-1
V
H
IDUXPIC
STM-1
STM-1STM-1
IDU replacement
only
IDU replacement
only
Same ODUfor V and H
Same ODUfor V and HSTM-1/128QAM
STM-2/128QAM(310MB)
2xSTM-1/XPIC 2xSTM-1/Carrier/XPIC
NEO Enhanced
One Box (IDU)
V
H
47472007NOV15 2007NOV15 NEC Confidential NEC Confidential
IDUXPIC ODU
STM-2/128QAM(310MB)
ODUIDUXPIC
56MHz
STM-2(310MB
)
56MHz
STM-2(310MB
)STM-2(310MB
)
STM-2 / Carrier
High Capacity Radio
STM-2/128QAM(310MB)
IDU ODU
2xSTM-2 /XPIC
GbE
GbE
GbE
NEO Enhanced
GbE over STM-4One Box (IDU)
V
H
STM-2/128QAM(310MB)
48482007NOV15 2007NOV15 NEC Confidential NEC Confidential
IDUXPIC ODU
STM-2/128QAM(310MB)
ODUIDUXPIC
56MHz
STM-2(310MB
)STM-2(310MB
)
High Capacity Radio
2xSTM-2 / XPIC / STM-4 Interface
STM-4
NEO Enhanced
One Box (IDU)
V
H
STM-2/128QAM(310MB)
49492007NOV15 2007NOV15 NEC Confidential NEC Confidential
Available 2007Products Road Map
2008 2009
High Capacity
IP Transport
Nodal Radio
DynamicModulation
Radio
16E1+2LAN(80MB)48E1, 4port LAN1E3/2E3STM-1(opt/elec), STM-1(2LAN)WS/LAN, APS, XPICGbE16E1+2LAN DXC (2Way Repeater)
StandardFunctionality
2xSTM-1/XPIC
80/96E1/XPIC 2xSTM-2
/XPIC
2Way Repeater
FE, GbEVLAN/QoS
(4FE, 3FE+GbE)
32E1+2LAN(100MB)
2/3/4x2Way 4xSTM-1/XPIC
STM-4 InterfaceGbE(620MB)
6Way/2x6Way48E1/DXC63E1PDH SNCP
DynamicModulation(hit-type<300ms typical)
DynamicModulation(hitless-type:<50ms)
GbE(300Mb/600Mb)(XPIC+Link aggregation)
75E1/Carrier
DynamicModulation(Trial)
GbE(300MB)(XPIC+Link aggregation)
STM-2/Carrier