Transcript

8

1

4

1

6

2

4

7

10

14

8

8

2

8 31

2

63

PEDESTRIAN AND VEHICULAR

ACCESS TO BE CLOSED.

REMOVE EXISTING GATE AND

INSTALL NEW CHAIN LINK FENCE.

TOPSOIL AND SOD

ONE STRIP OF SOD

TOPSOIL AND SOD

ONE STRIP OF SOD

PRECAST CONCRETE UNIT PAVERS

REFER TO NOTE #3

PRECAST CONCRETE UNIT PAVERS

REFER TO NOTE #3

7

PROPOSED COURTYARD.

REFER TO LANDSCAPE

NOTE #4.

AREA TO BE SEEDED

WHERE REGRADING

IS REQUIRED

AREA TO BE SEEDED

WHERE REGRADING

IS REQUIRED

AREA TO BE SEEDED

WHERE REGRADING

IS REQUIRED

2

5

L-2

14

14

27

2

X

X X X X

XX

XX

X

XXXX

X

6

SNOW STORAGE

LOCATION

EXISTING FENCE TO REMAIN

REPAIR

DAMAGED FENCE

IN THIS SECTION

STOP SIGN

BOLLARD

X X X X X X

1. REFER TO ENGINEERING DRAWINGS FOR PROPOSED

GRADING.

2. REFER TO TREE CONSERVATION REPORT AND DRAWING

TC -2 (PROPOSED DEVELOPMENT AND CONSERVED

VEGETATION) FOR A LIST AND LOCATION OF TREES AND

STUMP TO BE REMOVED FROM SITE.

3. PRECAST CONCRETE UNIT PAVERS (50 mm x 610mm x

610mm) TO BE VERSAILLES ROCART SLABS BY

PERMACON OR APPROVED EQUIVALENT. COLOUR TO BE

TRENTON LIMESTONE GREY. REFER TO DETAIL 4/L-2 FOR

INSTALLATION.

4. CEDAR FIBRE SURFACE TO BE CEDAR WEAVE OR

APPROVED EQUIVALENT. COLOUR TO BE NATURAL.

5. CONTRACTOR TO LOCATE AND STAKE ALL UTILITIES

PRIOR TO ANY WORK ON THE SITE. DO NOT PLANT

DIRECTLY ABOVE UNDERGROUND UTILITIES. REPORT

ANY DISCREPANCIES TO THE LANDSCAPE ARCHITECT

FOR DIRECTION.

6. NO TREES SHALL BE PLANTED UNDER OVERHEAD WIRES.

7. ALL LAYOUT TO BE STAKED BY THE CONTRACTOR AND

APPROVED BY THE LANDSCAPE ARCHITECT PRIOR TO

CONSTRUCTION. CONTRACTOR TO COORDINATE

STAKEOUT SO AS NOT TO CAUSE ANY UNDO DELAY OF

PLANTING.

8. THE LANDSCAPE ARCHITECT MAY ADJUST THE LOCATION

OF TREES PRIOR TO PLANTING TO MINIMIZE CONFLICTS

WITH UTILITIES, DRIVEWAYS AND INTERSECTION

VISIBILITY.

9. CONTRACTOR SHALL SUPPLY ALL MATERIALS IN

QUANTITIES SUFFICIENT TO COMPLETE WORK SHOWN

ON THESE DRAWINGS. ANY DISCREPANCIES SHALL BE

REPORTED TO THE LANDSCAPE ARCHITECT FOR

DIRECTION.

10. DO NOT MAKE SUBSTITUTIONS OF MATERIALS,

PRODUCTS OR QUANTITIES WITHOUT PRIOR WRITTEN

PERMISSION OF THE LANDSCAPE ARCHITECT.

11. THE CONTRACTOR TO MAKE GOOD TO THE

SATISFACTION OF THE LANDSCAPE ARCHITECT ANY

AREAS DAMAGED BY THE WORK.

12. UPON THE COMPLETION OF WORK EACH DAY, REMOVE

ALL DEBRIS, GARBAGE AND SURPLUS MATERIALS FROM

THE SITE. KEEP THE SITE CLEAN AND USEABLE AT ALL

TIMES.

13. ALL WORKMANSHIP AND MATERIALS (INCLUDING PLANTS)

TO BE GUARANTEED FOR TWO FULL YEARS FOLLOWING

FINAL ACCEPTANCE OF THE PROJECT.

14. THE CONTRACTOR SHALL REMOVE ALL T-BAR AND

WOODEN TREE STAKES PRIOR TO ASSUMPTION BY THE

OWNER.

15. AT THE TIME OF INSPECTION FOR ACCEPTANCE ALL

TREE PITS SHALL BE CULTIVATED, FREE OR WEEDS,

LEAVES, BROKEN BRANCHES AND DEBRIS.

1. THIS DRAWING FORMS PART OF A SET AND MAY NOT BE

SEPARATED. THIS DRAWING IS TO BE READ IN CONJUNCTION

WITH ALL OTHER DRAWINGS, NOTES AND SPECIFICATIONS IN

THE CONTRACT DOCUMENTS.

2. THIS DRAWING SHALL NOT BE USED FOR CONSTRUCTION

UNLESS STAMPED AND SIGNED BY THE LANDSCAPE ARCHITECT.

3. ANY AMBIGUITY IN THIS DRAWING OR ACCOMPANYING DETAILS

IS TO BE REPORTED TO THE LANDSCAPE ARCHITECT FOR

DIRECTION. DO NOT PROCEED IN UNCERTAINTY.

4. DRAWINGS NOT TO BE SCALED. USE FIGURE DIMENSIONS

ONLY.

PART OF LOT 21, CONCESSION 2 (OTTAWA FRONT),

GEOGRAPHIC TOWNSHIP OF NEPEAN, NOW CITY OF OTTAWA

1.20m HIGH PAIGE WIRE FARM FENCE,

MAXIMUM OPENING 150mm, SECURED TO

POSTS ON UPHILL SIDE

2.4m HIGH T-BAR STAKES AT 3.0m CENTRES

MAXIMUM

EXISTING GRADE

EXISTING TREE

1220

1220

UNDISTURBED EXISTING GRADE

CRITICAL ROOT ZONE (CRZ)

1. GROUPS OF TREES AND OTHER EXISTING VEGETATION TO BE

PROTECTED SHALL BE TREATED IN A LIKE MANNER WITH FENCING

AROUND THE ENTIRE STAND(S). PROTECTIVE FENCING SHALL BE

ERECTED AT CRZ FOR GROUP OF TREES AND AT A MINIMUM OF 1.5

METRES BEYOND THE DRIP LINE FOR SHRUB BEDS, AT THE

DISCRETION OF CITY STAFF.

2. THE CRITICAL ROOT ZONE (CRZ) IS THE AREA UNDER A TREE WHERE

THERE SHOULD BE NO DISTURBANCE BEFORE, DURING AND AFTER

CONSTRUCTION. THE CRZ IS ESTABLISHED AS BEING 10 CENTIMETRES

FROM THE TRUNK OF THE TREE FOR EVERY CENTIMETRE OF TRUNK

DIAMETER.

3. AREAS WITHIN THE PROTECTIVE FENCING SHALL REMAIN

UNDISTURBED AND SHALL NOT BE USED FOR THE STORAGE OF

BUILDING MATERIALS OR EQUIPMENT, OR PARKING OF VEHICLES.

4. NO RINGING CABLES SHALL BE WRAPPED AROUND OR INSTALLED IN

TREES. SURPLUS SOIL, EQUIPMENT, DEBRIS OR MATERIALS SHALL

NOT BE PLACED OVER ROOT SYSTEMS OF THE TREE(S) WITHIN THE

PROTECTIVE FENCING.

5. WHERE SOME FILL MUST BE TEMPORARILY LOCATED NEAR THE CRZ, A

PLYWOOD BARRIER MUST BE USED TO ENSURE NO MATERIAL ENTERS

THE CRZ.

6. ANY OPEN FACE CUTS OUTSIDE OF A CRZ THAT ARE CONSISTENT

WITH AN APPROVED PLAN THAT REQUIRE ROOT PRUNING, REQUIRE

THE SERVICES OF A CERTIFIED ARBORIST OR QUALIFIED TREE

WORKER UNDER THE SUPERVISION OF A CERTIFIED ARBORIST.

7. FENCE TO BE INSPECTED ON A REGULAR BASIS AND MAINTAINED BY

CONTRACTOR IN PROPER CONDITION FOR THE ENTIRE DURATION OF

CONSTRUCTION.

8. SEDIMENT ACCUMULATIONS TO BE REMOVED BY CONTRACTOR WHEN

SEDIMENT DEPOSITS REACH TO WITHIN 150mm OF TOP OF FILTER

FABRIC BARRIER.

9. THE CONTRACTOR SHALL TAKE EVERY PRECAUTION NECESSARY TO

PREVENT DAMAGE TO THE TREES TO BE RETAINED.

NOTES:

Plant Material ListSYM Qty Botanical Name Common Name Size Remarks

DECIDUOUS TREES - Refer to detail 1/L-2 and 2/L-2AR 10 Acer rubrum 'Franksred'

Red Sunset Maple

70 mm CAL. W.B.

AL 4 Amelanchier lamarckii Juneberry 1750 mm HT W.B.; multistem

JC 7

Juglans cinerea

Butternut 1000 mm HT

Potted; to be planted @ 4.0m o/c

SR 9 Syringa reticulata Japanese Tree Lilac 1750 mm HT W.B.; tree form

CONIFEROUS TREES - Refer to detail 1/L-2PG 32

Picea glauca White Spruce

1750 mm HT W.B.

DECIDUOUS SHRUBS - Refer to detail 3/L-2EA 63

Euonymus alatus Burningbush

600 mm HT

Potted; to be planted @ 1.5m o/c

RJ 99 Rosa 'Jens Munk' (Canadian Explorer) Rosa Jens Munk 600 mm HT

Potted; to be planted @ 1.2m o/c

115 Walgreen Rd., R.R. #3, Carp ON. K0A 1L0

Tel.: (613) 836-2184Fax: (613) 836-3742

Client:

SHEET of

Date

Do not scale drawings

No.

before proceeding with the workCheck and verify all dimensions

Revision/Issue

Project:

Project Number:

Drawing Number:

Drawing Title:

Checked By:

Drawn by:

Date:

Scale:

plan scale: sheet size: ctb file: layer states:

Designed by:

Owner:

LANDSCAPE PLAN

VARIES

ILL

ILL

L-11 2

ILL

2 ISSUED FOR SITE PLAN APPLICATION AUG. 13/12

1 ISSUED FOR COMMENTS JUL. 25/12

SCALE BAR:

LEGEND

GENERAL NOTES

LEGAL DESCRIPTION:

KEY MAP

LANDSCAPE NOTES

1

L-1

LANDSCAPE PLAN

SCALE 1:400

2

L-1

TREE PROTECTION FENCE

N.T.S.

3 REISSUED FOR SITE PLAN APPLICATION DEC. 14/12

4 FEB.6/13REISSUED FOR SITE PLAN APPLICATION

Top Related