![Page 1: power generation through solar power for PV module applications](https://reader034.vdocument.in/reader034/viewer/2022042722/5889073a1a28abcf5f8b7353/html5/thumbnails/1.jpg)
HIGH BOOST RATIO HYBRID TRANSFORMER DC-DC CONVERTER FOR PHOTOVOLTAIC
MODULE APPLICATION
Under the guidance ofMr.K.KRISHNA KUMAR
PRESENTED BY: M.Anusha(11A21A0269)
L.Santosh kumar(11A21A0261)
M.Sai kumar(11A21A0262) M.Rohith singh(11A21A0263)
![Page 2: power generation through solar power for PV module applications](https://reader034.vdocument.in/reader034/viewer/2022042722/5889073a1a28abcf5f8b7353/html5/thumbnails/2.jpg)
The main objective of this project is a high boost ratio hybrid transformer is increasing the efficiency of the converter for photovoltaic module applications.
Switching losses are reduced.
Able to implement maximum power point tracking(MPPT)
Current ripple and conduction losses are also reduced.
Output efficiency is greater than 96%
OBJECTIVES
![Page 3: power generation through solar power for PV module applications](https://reader034.vdocument.in/reader034/viewer/2022042722/5889073a1a28abcf5f8b7353/html5/thumbnails/3.jpg)
The main drawback of the converter there
was a High input current ripple.
Output diode stresses are increased.
Light load efficiency of the converter is reduced because of switching losses are more dominent under light load condition.
PROBLEM IDENTIFICATION
![Page 4: power generation through solar power for PV module applications](https://reader034.vdocument.in/reader034/viewer/2022042722/5889073a1a28abcf5f8b7353/html5/thumbnails/4.jpg)
Conventional systems
High step-up dc–dc converters using coupled-inductor and switched-capacitor techniques. (a) High-step coupled-inductor roboost dc-dc converter.(b) High step-up dc-dc converter with coupled-inductor and switched-capacitor.
![Page 5: power generation through solar power for PV module applications](https://reader034.vdocument.in/reader034/viewer/2022042722/5889073a1a28abcf5f8b7353/html5/thumbnails/5.jpg)
PREVIOUS METHODS: 1.High step coupled inductor boost DC-DC converter 2. High step up DC-DC converter with coupled inductor and switched capacitor PROPOSED METHOD: High boost ratio hybrid transformer DC-DC converter
SOLUTION METHODS
![Page 6: power generation through solar power for PV module applications](https://reader034.vdocument.in/reader034/viewer/2022042722/5889073a1a28abcf5f8b7353/html5/thumbnails/6.jpg)
The previous methods drawbacks are overcomed by using high boost ratio hybrid transformer DC-DC converter.
This method is advantageous for a two stage PCS.
By using this method, we achieve high level efficiency.
The inductive and capacitive energy can be transferred simultaneously to the high voltage DC bus.
Increasing the total delivered power and decreases the losses in the circuit.
Adding resonant inductor and reducing the capacitance of the switched capacitor in energy transfer path.
PROBLEM FORMULATION
![Page 7: power generation through solar power for PV module applications](https://reader034.vdocument.in/reader034/viewer/2022042722/5889073a1a28abcf5f8b7353/html5/thumbnails/7.jpg)
DC-DC conversion stage using PCS.
ABOUT PREVIOUS METHODS
![Page 8: power generation through solar power for PV module applications](https://reader034.vdocument.in/reader034/viewer/2022042722/5889073a1a28abcf5f8b7353/html5/thumbnails/8.jpg)
PCS accomplished single stage or double stage
The double-stage PCS consists of a dc–dc conversion stage that is connected to either a low power individual inverter.
a high-power centralized inverter have multiple inverters.
The high boost ratio dc–dc conversion stage of the PCS requires a high efficiency.
![Page 9: power generation through solar power for PV module applications](https://reader034.vdocument.in/reader034/viewer/2022042722/5889073a1a28abcf5f8b7353/html5/thumbnails/9.jpg)
The high boost ratio DC-DC converter sare isolated or non isolated .
However, transformer-isolated converters tend to be less efficient and more expensive due to the increased manufacturing costs.
A non isolated dc–dc converter with a high boost ratio would be advantageous for a two-stage PCS
Because it can be easily integrated with current PV systems while reducing the cost and maintaining a high system efficiency
![Page 10: power generation through solar power for PV module applications](https://reader034.vdocument.in/reader034/viewer/2022042722/5889073a1a28abcf5f8b7353/html5/thumbnails/10.jpg)
Combination of coupled inductor and boost converter:
![Page 11: power generation through solar power for PV module applications](https://reader034.vdocument.in/reader034/viewer/2022042722/5889073a1a28abcf5f8b7353/html5/thumbnails/11.jpg)
DC-DC converter with coupled inductor and switched capacitor:
![Page 12: power generation through solar power for PV module applications](https://reader034.vdocument.in/reader034/viewer/2022042722/5889073a1a28abcf5f8b7353/html5/thumbnails/12.jpg)
The above methods was proposed to increase the boost ratio without significant cost and efficiency penalties
Light load efficiency of the converter is reduced
because switching losses were more dominant under light load conditions.
In this leakage inductance is produced. It provides severe rigging and additional voltage stress on diode.
Ripple current increased
![Page 13: power generation through solar power for PV module applications](https://reader034.vdocument.in/reader034/viewer/2022042722/5889073a1a28abcf5f8b7353/html5/thumbnails/13.jpg)
Now a days electric power is more important . Generating electric power from the
renewable energy sources. For that PV modules are increasing day by
day. The output of the PV module is in b/w 20-45v. By using non isolated step up transformer
DC-DC converter
EXPLANATION
![Page 14: power generation through solar power for PV module applications](https://reader034.vdocument.in/reader034/viewer/2022042722/5889073a1a28abcf5f8b7353/html5/thumbnails/14.jpg)
High boost ratio non isolated dc–dc converter ,a clamp-mode couple-inductor buck–boost converter.
The converter’s leakage energy from the coupled-inductor was recycled reducing the losses of the system.
The output diode stress for this converter was similar to that of a traditional fly back converter, i.e., higher than the output dc bus voltage.
Another drawback of the converter was that there was a high input current ripple due to the fact that there was no direct energytransfer path when the MOSFET was OFF.
Conventional System
![Page 15: power generation through solar power for PV module applications](https://reader034.vdocument.in/reader034/viewer/2022042722/5889073a1a28abcf5f8b7353/html5/thumbnails/15.jpg)
EQUIVALENT CIRCUIT
![Page 16: power generation through solar power for PV module applications](https://reader034.vdocument.in/reader034/viewer/2022042722/5889073a1a28abcf5f8b7353/html5/thumbnails/16.jpg)
C= input capacitorHT= hybrid transformer with turns ratio 1:nS1=active MOSFET switchD1=clamping diodeCc=clamped capacitorLr=resonant inductorCr=resonant capacitor
![Page 17: power generation through solar power for PV module applications](https://reader034.vdocument.in/reader034/viewer/2022042722/5889073a1a28abcf5f8b7353/html5/thumbnails/17.jpg)
OPERATING MODES
![Page 18: power generation through solar power for PV module applications](https://reader034.vdocument.in/reader034/viewer/2022042722/5889073a1a28abcf5f8b7353/html5/thumbnails/18.jpg)
The important function of the dc–dc converter for PV applications is being able to implement maximum power point tracking (MPPT).
This paper presents a non isolated, high boost ratio hybrid transformer dc–dc converter with applications for low-voltage renewable energy sources.
The proposed converter utilizes a hybrid transformer to transfer the inductive and capacitive energy simultaneously.
achieving a high boost ratio with a smaller sized.
![Page 19: power generation through solar power for PV module applications](https://reader034.vdocument.in/reader034/viewer/2022042722/5889073a1a28abcf5f8b7353/html5/thumbnails/19.jpg)
From the circuit , we calculate boost ratio: The first flux balance on the
magnetizing inductor of hybrid transformer
Vcc =Vin/(1-D) Second flux, according to the flux
balance on the resonant inductor. Vcr= nVin+Vcc =(n+1/(1-D))
![Page 20: power generation through solar power for PV module applications](https://reader034.vdocument.in/reader034/viewer/2022042722/5889073a1a28abcf5f8b7353/html5/thumbnails/20.jpg)
The last flux balance that governs circuit is voltage second balance of the magnetizing inductor
VinD= (Vo-Vcr-Vin)/(1+n)*(1-D)
The boost conversion ratio Mb=Vo/Vin=n+2/n-D
![Page 21: power generation through solar power for PV module applications](https://reader034.vdocument.in/reader034/viewer/2022042722/5889073a1a28abcf5f8b7353/html5/thumbnails/21.jpg)
BLOCK DIAGRAM
![Page 22: power generation through solar power for PV module applications](https://reader034.vdocument.in/reader034/viewer/2022042722/5889073a1a28abcf5f8b7353/html5/thumbnails/22.jpg)
MODES OF OPERATION
![Page 23: power generation through solar power for PV module applications](https://reader034.vdocument.in/reader034/viewer/2022042722/5889073a1a28abcf5f8b7353/html5/thumbnails/23.jpg)
SIMULATION CIRCUIT
![Page 24: power generation through solar power for PV module applications](https://reader034.vdocument.in/reader034/viewer/2022042722/5889073a1a28abcf5f8b7353/html5/thumbnails/24.jpg)
0 0.01 0.02 0.03 0.04 0.05 0.06 0.07 0.08 0.09 0.1-100
0
100
200
300
400
500
time(sec)
voltage(volts)
OUTPUT VOLTAGE
![Page 25: power generation through solar power for PV module applications](https://reader034.vdocument.in/reader034/viewer/2022042722/5889073a1a28abcf5f8b7353/html5/thumbnails/25.jpg)
0 0.01 0.02 0.03 0.04 0.05 0.06 0.07 0.08 0.09 0.1-0.1
0
0.1
0.2
0.3
0.4
0.5
0.6
time(sec)
current(amps)
OUTPUT CURRENT
![Page 26: power generation through solar power for PV module applications](https://reader034.vdocument.in/reader034/viewer/2022042722/5889073a1a28abcf5f8b7353/html5/thumbnails/26.jpg)
0 0.01 0.02 0.03 0.04 0.05 0.06 0.07 0.08 0.09 0.139
39.5
40
40.5
41
Time(sec)
voltage(volts)
INPUT VOLTAGE
![Page 27: power generation through solar power for PV module applications](https://reader034.vdocument.in/reader034/viewer/2022042722/5889073a1a28abcf5f8b7353/html5/thumbnails/27.jpg)
0 0.01 0.02 0.03 0.04 0.05 0.06 0.07 0.08 0.09 0.10
50
100
150
200
250
Time(sec)
power(watts)
OUTPUT POWER
![Page 28: power generation through solar power for PV module applications](https://reader034.vdocument.in/reader034/viewer/2022042722/5889073a1a28abcf5f8b7353/html5/thumbnails/28.jpg)
DESIGN PARAMETERS
![Page 29: power generation through solar power for PV module applications](https://reader034.vdocument.in/reader034/viewer/2022042722/5889073a1a28abcf5f8b7353/html5/thumbnails/29.jpg)
A high boost ratio dc–dc converter with hybrid transformer suitable for alternative dc energy sources with low dc voltage input is proposed in this paper.
The resonant conversion mode is incorporated into a traditional high step-up PWM converter with coupled-inductor and switched-capacitor.
FUTURE SCOPE
![Page 30: power generation through solar power for PV module applications](https://reader034.vdocument.in/reader034/viewer/2022042722/5889073a1a28abcf5f8b7353/html5/thumbnails/30.jpg)
CONCLUSION
![Page 31: power generation through solar power for PV module applications](https://reader034.vdocument.in/reader034/viewer/2022042722/5889073a1a28abcf5f8b7353/html5/thumbnails/31.jpg)
1. J.-S. Lai, “Power conditioning circuit topologies,” IEEE Ind. Electron. Mag., vol. 3, no. 2, pp. 24–34, Jun. 2009.2
2. S. B. Kjaer, J. K. Pedersen, and F. Blabber, “A review of single-phase grid-connected inverters for photovoltaic modules,” IEEE Trans. Ind. Appl., vol. 41, no. 5, pp. 1292–1306, Sep./Oct. 2005.
REFERENCES