![Page 1: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/1.jpg)
Precision Focusing with FocusMax
Steve Brady http://focusmax.org
![Page 2: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/2.jpg)
Precision Focusing with FocusMax
CCD Astronomers Hate Focusing!!
![Page 3: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/3.jpg)
I have been chasing focus demons for many years!
My First Telescope Circa: 1964
![Page 4: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/4.jpg)
My Astro-Cameras
1960’s
1980’s
1970’s
![Page 5: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/5.jpg)
My Astro-Cameras ST-8 XME
How do you focus this thing ???
1990’s
![Page 6: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/6.jpg)
FocusMax was developed by Steve & Larry to address a missing link in observatory
automation
![Page 7: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/7.jpg)
FocusMax Goals
• Accuracy equal to or better than manual focusing • Fast so that valuable observing time is not lost • Robust so that the user can expect it to arrive at
the correct focus even in marginal conditions • Capable of accommodating a wide range of initial
out of focus star diameters • Operate as an automation client for unattended
observing (ACP, CCAP, CCDC,….)
![Page 8: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/8.jpg)
Degree of Focus Metric
Half Flux Diameter (HFD) The diameter of a circle centered on the unfocused star in which half of the total star flux is inside the circle and half is outside
HFD
![Page 9: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/9.jpg)
Degree of Focus Metric
• HFD units are CCD pixels • Relatively insensitive to variations in seeing • Accurate over a wide range of unfocused star
diameters • HFD is determined by integrating all of the flux
from the unfocused star
![Page 10: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/10.jpg)
Vcurve
A plot of HFD vs. focuser position yields a ‘V’ shape The ‘wings’ of the curve are linear which are dependant on
– optical f/ratio – CCD pixel size – focuser gear ratio – etc.
![Page 11: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/11.jpg)
Vcurve H
FD
Focuser PositionPID
0
![Page 12: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/12.jpg)
Vcurve H
FD
Focuser PositionPID
0 PNF
Near Focus Position (NF)
Best Focus = PNF + HFD/LS - PID/2
![Page 13: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/13.jpg)
Vcurve
FocusMax automatically determines: • Slope of the Right & Left lines • Position Intercept • Position Intercept Difference (PID)
![Page 14: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/14.jpg)
Focus Tab
Vertical bin of the sub-framed star Detected star boundaries
![Page 15: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/15.jpg)
Focus Tab
Location of star on camera chip
![Page 16: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/16.jpg)
Focus Tab
Flux integral plot of the star diameter along the x-axis and integrated flux along the y-axis. HFD is the point marked with a vertical line
0 100 diameter
![Page 17: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/17.jpg)
Focus Tab
Find button : • Take a full frame image • Find brightest star • Subframe star
![Page 18: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/18.jpg)
Focus Tab
Expose button : • Take a subframe image
centered on star from ‘Find’ star process
Star position on CCD must be known
![Page 19: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/19.jpg)
Focus Tab
Focus button: • Take a full frame image • Find brightest star in image • Subframe star • Move focuser to Start Position • Move focuser to Near Focus Position • Take repetitive subframe images • Measure HFD and calculate Best Focus
position
![Page 20: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/20.jpg)
Focus Tab
Select button (MaxIm only): •Take full frame image •User clicks on target star with mouse •Autofocus is initiated
•Useful if user does not want to leave present field
•Blobs (deep sky objects) will confuse FocusMax and report larger HFD values (they appear as out of focus stars)
![Page 21: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/21.jpg)
Focus Tab
AcquireStar button: • Take image and plate solve current
telescope position * • Look up target stars from catalog • Slew telescope • Center target star • Autofocus • Return slew • Take image and plate solve telescope
position * • Fine tune pointing to user defined error
•Requires full feature PinPoint (http://www.dc3.com/)
![Page 22: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/22.jpg)
Setup Tab
Near Focus: • HFD - position used to determine focus
position
• Exposures - the number of subframe images used to determine the final focus position
![Page 23: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/23.jpg)
Setup Tab
Move: •Set focuser move direction and settle time to prevent image wiggle
•Focuser movement will be toward focus to eliminate backlash
•Move direction is often set to move load against gravity
![Page 24: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/24.jpg)
Setup Tab
Autofocus: • Initial subframe width • Target star binning (1 – 4) • Focus binning (1 & 2) • Min/Max Exposure • Min/Max Flux • Base exposure
![Page 25: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/25.jpg)
Setup Tab
Autofocus example: • Star will be found using 3x3 binning • Focus Bin will be 1x1 • Initial subframe will be 50 x 50 pixels
![Page 26: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/26.jpg)
Setup Tab
Autofocus example:
•First exposure will be 1.00 sec and may be adjusted up or down to meet the midpoint of the Flux range of 50K – 500K
•Last resort: - If the star is too dim then it will attempt to target Min Flux
- If the star is too bright it will attempt to target Max Flux setting
![Page 27: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/27.jpg)
Setup Tab
Autofocus exposure calculation: Target Flux = (500K + 50K)/2 = 275,000 Base Exp. = 1.0 sec Measured star Total Flux = 536,401 New Exp = 1.0 x (275K/536K) = 0.51 sec
![Page 28: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/28.jpg)
Max Flux Setting (CCD Linearity Test)
• Select moderately faint, isolated star near the zenith • Focus telescope • Set Min Flux to 0 on Setup Tab • Enable CCD Central Region on Features Tab and set to 25% (or
smaller) • Set Base Exp. to 0.1 sec • Press Find and verify that FocusMax identifies the target star • Note the Exp., Max Pixel and Total Flux in Log • Increase Base Exp. to 0.5 press Find • Increase Base Exp. To 1 sec and repeat in intervals of 2 sec until
reach 30 sec (can be automated in MaxIm using Autosave feature)
• Construct a plot of Max Pixel vs. Exp. time
![Page 29: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/29.jpg)
0
10,000
20,000
30,000
40,000
50,000
60,000
70,000
0 5 10 15 20 25 30
Max
Pix
el
Exposure (sec)
Max Flux Setting
Plot Max Pixel vs. Exp time
![Page 30: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/30.jpg)
0
10,000
20,000
30,000
40,000
50,000
60,000
70,000
0 5 10 15 20 25 30
Max
Pix
el
Exposure (sec)
Max Flux Setting
58
174
411
523
756 866
290
640 Add Total Flux (x1000)
Plot Max Pixel vs. Exp time
![Page 31: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/31.jpg)
0
10,000
20,000
30,000
40,000
50,000
60,000
70,000
0 5 10 15 20 25 30
Max
Pix
el
Exposure (sec)
Max Flux Setting
58
174
411
523
756 866
290
640 • Identify region where plot
levels off due to pixel saturation
• Set Total Flux to some value less than above region on Setup Tab
• When Total Flux approaches 700K then CCD is approaching saturation for star at focus
CCD Saturated
Max Flux Setting ~700K
![Page 32: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/32.jpg)
Setup Tab
Focus Start: • Position - move focuser immediately to the
listed position (fastest method but position must be current from recent autofocus run)
• HFD - requires finding the focuser at HFD setting (medium speed - preferred)
• Current Position - start at current focuser position and then find HFD position (slowest)
![Page 33: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/33.jpg)
Setup Tab
Move to Focus Start HFD
10
20
HFD
![Page 34: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/34.jpg)
Setup Tab
Move to Near
10
20
Move is out
HFD
![Page 35: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/35.jpg)
Setup Tab
10
20
Take (5) 1x1 images
HFD
Move is out
![Page 36: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/36.jpg)
Setup Tab
10
20
Move to Focus Position
Make final move
HFD
![Page 37: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/37.jpg)
FocusMax Tour Features Tab
Image Calibration: Help eliminate ‘hot pixel’ that may cause FocusMax to think a it is a star for focusing
MaxIm • Create a set of dark frames in the
Min/Max exposure range and binning • Create a set of bias frames • Save frames to a directory • Load frames into MaxIm using Set
Calibration CCDSoft
• FocusMax will utilize Image Reduction: AutoDark with each frame taken
![Page 38: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/38.jpg)
Features Tab
AcquireStar: Automated target star acquisition, star centering and autofocus
![Page 39: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/39.jpg)
Features Tab
CCD Central Region: • Limit the area for target star detection
to central region on the CCD • Reduces impact of curvature of field
and coma • Recommended for wide field / large
format cameras
![Page 40: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/40.jpg)
Features Tab
Focus Routine: • Return to Start Position triggered by:
- Autofocus HFD > Max HFD - Lost star - Clouds
• Max HFD - largest allowed HFD • Fail Attempts - number of tries to achieve
focus • Fail Timer - delay before autofocus
routine is attempted again (clouds) Useful for unattended all night runs
![Page 41: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/41.jpg)
Features Tab
Focus Convergence: Will determine the best focus position by taking repeated subframe images until the average HFD falls within a user defined tolerance • Steps - the number of focuser steps (units)
that the average HFD must fall within
• Samples - the number of consecutive measurements that must fall within the above Steps setting before making the final focuser move
![Page 42: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/42.jpg)
Focus Convergence
4160
4165
4170
4175
4180
4185
4190
4195
4200
1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35
FMx default of 5 Near Focus Exposures (Convergence off)
Focus 4196 Steps = 2 Samples = 10
Delta = 19 steps
![Page 43: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/43.jpg)
Accuracy & Precision
Reference value
Accuracy
Precision
![Page 44: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/44.jpg)
Accuracy & Precision
High accuracy Low precision
Low accuracy High precision
![Page 45: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/45.jpg)
Focus Repeatability (Precision)
Time Temp Position HFD Delta
(steps) 4.50.55 4.5 2571 3.59 4.52.54 4.5 2574 3.66 -3 4.55.26 4.5 2573 3.66 1 5.04.10 4.5 2573 3.7 0 5.10.09 4.5 2567 3.76 6 5.13.11 4.5 2565 3.77 -2 5.17.25 4.5 2571 3.99 -6 5.19.27 4.5 2569 4.08 2
Precision (error)
![Page 46: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/46.jpg)
Focus Repeatability
-3s=-16 3s=13.8
Avg=-1.1
0
5
10
15
20
25
-20 -15 -10 -5 0 5 10 15 20
Freq
uenc
y
Steps
Convergence : 1 Step/10 Samples
![Page 47: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/47.jpg)
Focus Repeatability
0 2 4 6 8
10 12 14 16 18 20
Freq
uenc
y
-3s -2s -1s 1s 2s 3s
99.6%
95.4%
68.2%
-15 -10 -5 0 5 10 15
Expected distribution of readings
![Page 48: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/48.jpg)
Focus Repeatability
-3s=-16 3s=13.8
Avg=-1.1
0
5
10
15
20
25
-20 -15 -10 -5 0 5 10 15 20
Freq
uenc
y
Steps
Convergence : 1 Step/10 Samples
Total statistical error ≈ ± 15 steps
![Page 49: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/49.jpg)
Focus Repeatability
No significant difference with binning
-3s=-14.3 3s=14.3
0
2
4
6
8
10
12
14
-20 -15 -10 -5 0 5 10 15 20
Freq
uenc
y
Steps
2x2
-3s=-14.2 3s=11.6
0
2
4
6
8
10
12
14
16
-20 -15 -10 -5 0 5 10 15 20
Freq
uenc
y
Steps
1x1
![Page 50: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/50.jpg)
Focus Repeatability
-3s=-16 3s=13.8
Avg=-1.1
0
5
10
15
20
25
-20 -15 -10 -5 0 5 10 15 20
Freq
uenc
y
Steps
16" F/4.5 Newtonian Optec focuser 1 step = 2.18μ Total error = ± 15 x 2.18 = ± 33 μ = ± .0013”
![Page 51: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/51.jpg)
Focus Repeatability Is ± 33μ error good or bad??
-3s=-16 3s=13.8
Avg=-1.1
0
5
10
15
20
25
-20 -15 -10 -5 0 5 10 15 20
Freq
uenc
y
Steps
16" F/4.5 Newtonian Optec focuser 1 step = 2.18μ Total error = ± 15 x 2.18 = ± 33 μ = ± .0013”
![Page 52: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/52.jpg)
Critical Focus Zone and
“New” Critical Focus Zone **
** Get Focused! D. Goldman & B. Megdal Jan, 2010
CFZ = 4.88 * F2 * λ = 49 μ NCFZ = 1.6 * F2 * λ = 16 μ
![Page 53: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/53.jpg)
Critical Focus Zone and
“New” Critical Focus Zone **
CFZ = 4.88 * F2 * λ = 49 μ NCFZ = 1.6 * F2 * λ = 16 μ
My focus precision > CFZ & NCFZ CFZ & NCFZ does not take into account:
• Seeing • Telescope aperture
![Page 54: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/54.jpg)
Focus Repeatability
-15 -10 -5 0 5 10 15
What is the positional error of ± 15 steps as a percent of seeing ?
![Page 55: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/55.jpg)
“New Critical Focus Zone” **
Takes into account: • Seeing • Telescope aperture • Telescope focal ratio • Acceptable focus tolerance
** Dr. Jeff Winter http://www.goldastro.com/goldfocus/ncfz.php
![Page 56: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/56.jpg)
“New Critical Focus Zone”
NCFZ = 0.00225 · θFWHM · √τ · A · f 2 NCFZ (microns) 0.00225 - constant (microns per arc-sec/mm) θFWHM - total seeing (arc-sec) τ - focus tolerance as a percentage of total seeing (no units) A - telescope aperture (mm) f - effective imaging system f/ratio (no units)
![Page 57: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/57.jpg)
“New Critical Focus Zone” My 16” Newtonian:
θFWHM = 3.0” (my typical seeing) τ = ?? A = 16” x 25.4 = 406.4mm f = 4.5 NCFZ = 66µ total focus repeatability error Τ =
= 1.4% focus error in 3” seeing
![Page 58: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/58.jpg)
“New Critical Focus Zone”
3% focus error In 2” seeing 12% focus error in 1” seeing BUT I would expect much better focus repeatability (precision) in seeing better then 3 arc-sec!
![Page 59: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/59.jpg)
Focusing System • Good accuracy (center of CFZ) • Good precision
– Focuser step size should not be under sampled to CFZ – Under sampled means 1 focuser step >= CFZ
![Page 60: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/60.jpg)
Focusing System What should be the minimum focuser step resolution relative to the CFZ ?? 10:1 rule of thumb used in metrology
• “Measurements should be sensitive enough to detect differences as slight as one-tenth of the total tolerance “ (CFZ)
• “Inadequate discrimination will affect both accuracy and precision”
There is also a 4:1 rule but 10:1 has been universally adopted
![Page 61: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/61.jpg)
Setup Tab
Focuser: •Choose ASCOM Focuser •Setup focuser •Connect / Disconnect focuser •Enable native focuser driver temperature compensation
![Page 62: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/62.jpg)
Setup Tab
Backlash Compensation: • Set focuser backlash direction In/Out • Number of steps BL Setting may be available in focuser documentation You can measure the actual backlash with a drop indicator Older SCT telescopes may required up to 200 steps in cold temperatures
![Page 63: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/63.jpg)
Setup Tab
Imaging SW: Select either MaxIm Or CCDSoft
![Page 64: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/64.jpg)
Setup Tab
Profile: Current Vcurve parameters (from Profile window)
![Page 65: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/65.jpg)
Setup Tab
System: • The current user selected system.ini
file where data will be saved • Paths button allows you to change the
location of the Log files and Images
![Page 66: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/66.jpg)
System Profile
Shows the average Left & Right Slopes and PID
![Page 67: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/67.jpg)
System Profile
Vcurve run data • Enable / Disable row • Delete a row • Binning, Total points and number of good points
![Page 68: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/68.jpg)
System Profile
Vcurve run data: 1. Review Left & Right Slopes and PID 2. Delete values that look like fliers 3. Want ~ 12 good Vcurve rows in your Profile
![Page 69: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/69.jpg)
Auto-connect: Connect devices on startup • Focuser • Camera • Telescope
Default is none
Options
![Page 70: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/70.jpg)
Focus: •Enable Auto Subframe Width use subframe width defined on Setup Tab
•Offset - useful for photometry to defocus an image
•Final Focus Images - average the HFD of consecutive images when the focuser moves to the Best Focus position
Options
![Page 71: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/71.jpg)
Options
Focuser: Limit End of Travel Position prevent the focuser from reaching physical hard stop Polling Rate - set the time (sec) that the focuser is polled for temperature and position information
![Page 72: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/72.jpg)
General: •Flush Camera Images - consecutive 0 sec exposures at the end of the autofocus run to remove potential ghost image on the next image
•Font and Font Size can be set
•Graphic Colors Red, Green, Blue – useful for laptops with red mylar
Options
![Page 73: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/73.jpg)
Focus Plot
Predicted Focus Position for each subframe image – note variation in position from each image due to seeing Mean Best Focus - the average focus position
![Page 74: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/74.jpg)
FirstLight Wizard
• Handles limited range focusers FLI Optec focal reducer
• Gracefully handles sins of relative focusers Backlash End of mechanical travel
• Finds lost stars • Accurately sets up Vcurve range values
![Page 75: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/75.jpg)
FirstLight Wizard
• Manually focus the telescope • Make mechanical adjustments so that the
focus position is mid-way between the In and Out travel of the focuser
• Select a star near the zenith, press the Find button and verify in the Log that the resulting Min/Max Flux falls within the boundary on the Setup tab
• Verify that the star is not saturated
![Page 76: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/76.jpg)
FirstLight Wizard
• Select the First Light Wizard from the Wizard menu
• The wizard will prompt you at each step of the process
![Page 77: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/77.jpg)
FirstLight Wizard
• Wizard will start by moving the focuser away from the focus point to estimate the slope of one side of the ‘Vcurve’
• Will continue to move the focuser until it achieves the HFD setting (default = 40)
• If your focuser can not achieve this setting then re-run the First Light Wizard and reduce the HFD value when prompted
![Page 78: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/78.jpg)
FirstLight Wizard
• Once the slope has been estimated, the Vcurve is generated
• Vcurve results are saved in system Profile
![Page 79: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/79.jpg)
Manual Vcurve
1) Focus the telescope 2) Adjust focuser to midpoint of
focuser travel 3) Select 4 – 6th mag star (fainter
for larger apertures) near zenith 4) Open Vcurve window - current
focuser position will be entered
![Page 80: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/80.jpg)
Manual Vcurve
•Half Width - number steps away from focus •End Points - initial and final focuser positions •Step Increment - number of steps the focuser will move
•Steps - number of moves that will be made •Repeat - rerun the Vcurve • Images/position - take multiple images and average the HFD at each move (helps with seeing effects)
![Page 81: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/81.jpg)
Manual Vcurve
Method #1 - Half Width: 1) Manually focus the telescope 2) Press the Jog button and move the focuser
In or Out 100 units then press the Find button
3) Continue to move the focuser until you achieve an HFD of 20+ (30 - 40 is better)
4) Note the focuser position 5) Bring the focuser back to the focus
position and press the Half Width button on the Vcurve window
6) Enter the difference between the focus position and the position achieved when you manually jogged the focuser
7) Press Run
![Page 82: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/82.jpg)
Manual Vcurve
Method #1 Example: 1) Focus position is 3,500 and 4,000 was
the position to achieve 30 HFD 2) Enter the difference of 500 into the Half
Width box 3) Adjust the Step Increment value until you
see 30 - 40 Steps displayed 4) Press Run
![Page 83: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/83.jpg)
Manual Vcurve
Method #2 - End Points: 1) Press the End Points button on the Vcurve
window 2) Press the Jog button and move the focuser
‘Out’ 100 units then press the Find button 3) Continue to move the focuser until you
achieve an HFD of 20+ (30 - 40 is better) 4) Enter the focuser position in the Initial
position
![Page 84: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/84.jpg)
Manual Vcurve
Method #2 - End Points: 5) Move the focuser 200 units ‘In’ then press
the Find button 6) Continue to move the focuser until you find
the position approximately equal to the HFD from step 3
7) Enter the focuser position in the Final position
8) Bring the focuser back to the focus position
9) Press Run
![Page 85: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/85.jpg)
Manual Vcurve
Method #2 - Example: 1) Focus position is 3,596 2) Initial position = 3446 (In) to achieve 30
HFD 3) Final position = 3746 (Out) to achieve 30
HFD 4) Adjust the Step Increment value until you
see 30 – 40 Steps displayed 5) Press Run
![Page 86: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/86.jpg)
How are Slopes Determined?
Hyperbola fit to Vcurve • Line fit is tangent to hyperbola (‘wings’) • Gives better fit statistic
- uses both sides of V Curve for fit - rejects deviant points due to seeing
• Rejects flat spots due to - focuser backlash - focuser mechanical end of travel
![Page 87: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/87.jpg)
Setting Focus Start and Near Focus HFD (Setup Tab)
1) Generate a Vcurve 2) From the Log identify the right or left
most extreme HFD value (20.33)
![Page 88: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/88.jpg)
Focus Start and Near Focus HFD Settings (Setup Tab)
3) Examine the Vcurve graph and identify the circle which begins to deviate from a straight line
4) Determine HFD value in the Log by counting down to the circle number from step 2
![Page 89: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/89.jpg)
Focus Start and Near Focus HFD Settings (Setup Tab)
5) Round off the HFD value and enter the value in the Near Focus (11)
6) Enter the Focus Start HFD some 5 units higher than the Near Focus HFD (16)
![Page 90: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/90.jpg)
Acquire Star
Expose at Initial Scope
Position
Expose Plate Solve and Store Position
Adjust Scope Position if Necessary
Plate Solve
Slew to Auto Focus
Star
Search for Autofocus
Stars
Center Star on CCD
Autofocus
Slew back to Initial Position
![Page 91: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/91.jpg)
AcquireStar
Setup: • Return Slew after autofocus run
• Zenith – select stars from catalog
starting at zenith
• Meridian Cross- do not check for most German Equatorial mounts
![Page 92: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/92.jpg)
AcquireStar
Setup: • Settle Time after slew
• Min Altitude allowed for star
• Min Slew - set to 0 to use potential
star in current FOV
• Number of Stars to select from catalog
![Page 93: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/93.jpg)
AcquireStar
Setup: Center Star • None – blind slew to target star
• Auto – center star using calibrated
telescope moves (see Telescope window to calibrate)
• PinPoint – center star with plate
solved images with PinPoint
![Page 94: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/94.jpg)
AcquireStar
Target Star Selection: • Target Min/Max – target star
magnitude range to select from star catalog
• Bright / Sep (deg) – reject bright stars that are within 0.75 deg of potential target star.
• Dim / Sep (arc sec) - reject dim stars down to 11th mag that are within 120 arc-sec of a potential target star
![Page 95: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/95.jpg)
AcquireStar
Auto-center: • Final Pointing – fine tune
telescope pointing after slew
• Sync telescope after successful plate solve with PinPoint
• Spiral Search to determine telescope pointing – useful if target is not on chip
![Page 96: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/96.jpg)
AcquireStar
Auto-center: • Exposure time for plate solving
telescope pointing
• Max Error allowed on telescope slews. Will allow for < 1 arc-sec positioning if mount is able to make small accurate adjustments
• Attempts - the number of centering failures before declaring failure and telescope moves to next target star
![Page 97: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/97.jpg)
AcquireStar
Plate Parameters: • Binning for plate solves (1 – 4
allowed) • X & Y pixel scale (at 1x1 binning)
Catalog: • Select catalog and catalog path
• Test Path button will determine if
PinPoint can read selected catalog at RA 00:00:00 Dec 00:00:00
• Expose and Solve button – take an actual image and plate solve
![Page 98: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/98.jpg)
Temperature Compensation
•Maybe ‘black magic’ •May not work with all optical systems •Some users report non-linear response (APO) •Focuser should have a remote temperature probe •Probe should be coupled to telescope – preferably near primary optics
•Avoid taking measurements until telescope has acclimated to ambient temp
•Most telescopes will require moving focuser out as temp drops (tube shrinkage)
![Page 99: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/99.jpg)
Temperature Compensation
My 16” f/4.5 Newtonian • Optec focuser with external probe
• Drilled hole in side of tube and positioned probe next to mirror face
• Measured Temperature vs. Position over multiple nights with Temp Comp Wizard
![Page 100: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/100.jpg)
Temperature Compensation
My 16” f/4.5 Newtonian • Focus Convergence set to 1 Step, 10 Samples to assure adequate sampling
• Enabled AcquireStar with: Zenith enabled Return slew disabled Meridian Cross disabled PinPoint to center target star
• Binning = 1x1 (1.02 arc-sec/pixel)
• Seeing ~3 arc-sec FWHM
![Page 101: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/101.jpg)
Temperature vs. Position (Scatter Plot)
y = -9.9804x + 2862.1 R² = 0.8439
y = -8.5021x + 2794.3 R² = 0.7892
2700
2720
2740
2760
2780
2800
2820
2840
1 2 3 4 5 6 7 8 9 10
Posi
tion
Temperature
Night 1
Night 2
![Page 102: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/102.jpg)
Temperature vs. Position (Scatter Plot)
y = -9.9804x + 2862.1 R² = 0.8439
y = -8.5021x + 2794.3 R² = 0.7892
2700
2720
2740
2760
2780
2800
2820
2840
1 2 3 4 5 6 7 8 9 10
Posi
tion
Temperature
• Similar slopes • Good correlation (R2) • Line is shifted night 1 to 2 • Avg slope ~ 9 steps/degree C
Night 1
Night 2
![Page 103: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/103.jpg)
Temperature Compensation
Averaged temperature coefficients (slopes) over several nights
Result Able to extend time between autofocus from 60 minutes to 120 minutes
![Page 104: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/104.jpg)
Jeff Dickerman - Optec
![Page 105: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/105.jpg)
Temperature Compensation Wizard
• Collect temp & position data by performing repetitive focus runs • Use AcquireStar to identify star at zenith throughout the night
• Use Focus Convergence to reduce focus errors • Set time between autofocus runs • Will park the telescope at end of session
![Page 106: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/106.jpg)
Temperature Compensation
There is a lot more work to do! •Not all focusers are created equal for temperature sensing
•How to handle non-linear responses
•Where to place probe for closed tube telescopes
![Page 107: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/107.jpg)
Temperature Compensation FocusMax V4: • New autofocus routine that uses both sides of Vcurve • Several different TC methods • Will perform TC least square analysis on data • Plot TC data • Built in scripting capabilities • Plot Profile data •New focus plot graphics
![Page 108: Precision Focusing with FocusMax Focusing... · 2020. 4. 2. · Start HFD 10 20 H F D. Setup Tab Move to Near 10 20 . Move is out . H F D. Setup Tab 10 20 . Take (5) 1x1 images H](https://reader033.vdocument.in/reader033/viewer/2022053123/60aafa2653a33b0fd259ade9/html5/thumbnails/108.jpg)
Precision Focusing With FocusMax
CCD Astronomers using FocusMax Love Focusing!
Steve Brady http://focusmax.org http://tech.groups.yahoo.com/group/FMaxUG