Part No. CPD-360P
Product Information
CPD-360P is a passive infrared (PIR) ceiling mountable presence detector for lighting or HVAC automation control.
Presence Detector
• High performance presence detector• 360° detecton with lens shield, flush or surface mount• 30m detection zone• 2 Channel, 5 seconds to 30 minutes and 2nd channel 10 seconds to 60 minutes• Up to 10 slaves can be attached to extend to range (Part No. CPD-360P-SLAVE)• IP40 but IP54 with included surface mount junction box• Impulse mode to switch a staircase timer• Optional IR remote control• Suitable for halogen, Fluro and LED
FEATURES AND BENEFITS:
Flush mountable Surface mountable with junction box
Lens shield for detection angle adjustment
Master & Slave connection is for expanding detection coverage
Manual control & Auto/Semi-auto control are enabled by using external push button switch
Hand-held IR remote control (optional)
Product InformationSPECIFICATIONS:
Feature DescriptionLoad Load I (CH1) for Lighting:
Load II (CH2) for HVAC: (voltage free contact)
Incandescent Lamp: max. 2000WAC Halogen Lamp: max. 1000WLV Halogen Lamp: max. 1000VA/600W (traditional)LV Halogen Lamp: max. 1000VA/900W (electronics)Fluorescent Lamp: max. 900VA/100µFLV Halogen Lamp: 25 x (1 x 18W)LV Halogen Lamp: 12 x (2 x 18W)LV Halogen Lamp: 15 x (1 x 36W)LV Halogen Lamp: 7 x (2 x 36W)LV Halogen Lamp: 10 x (1 x 58W)LV Halogen Lamp: 5 x (2 x 58W)LV Halogen Lamp: max. 1000VA/600W (uncompensated)LED Lamp: max. 500VA/400WEnergy Saving Lamp: max. 600VA/400W (include CFL and PL Lamp)
max. 5A (cos φ = 1) for ≤ 250VACmax. 5A for ≤ 30VDCmax. 1A (cos φ = 0.4) for ≤ 250VAC
Detection Range 360° circular, up to � 30m at height of 2.5m
Lux Adjustment Adjustable from approx. 10 Lux to 2000Lux
Auto Off Time Time 1:(for lighting)
Time 2:(for HVAC)
Adjustable from approx. 10 seconds to 30 minutes and test &
Adjustable from approx. 10 seconds to 60 minutes and
Specifications CPD-360P CPD-360P-SlaveRATED VOLTAGE 220 - 240V ~ 50/60HZ 220 - 240V ~ 50/60HZ
LOAD I FOR LIGHTING V X
LOAD II FOR LIGHTING V X
LUX SETTING 10Lux to 2000Lux X
TIME 1 FOR LIGHTING 5 seconds - 30 minutes Test, X
TIME 2 FOR HVAC 5 seconds - 60 minutes X
OPERATING TEMPERATURE -20°C to +45°C 20°C to +45°C
ENVIRONMENTAL PROTECTION IP40, IP54 (with JB-41) IP40, IP54 (with JB-41)
DETECTION ANGLE 360° 360°
DETECTION RANGE Φ 30m Φ 30m
Product InformationDIMENSIONS (MM):
DETECTION COVERAGE:
· CPD-360P · Detector with junction box (included)
· Remote control (optional purchase) · CDP-P-RC