REV.SHT. DATE
APPLICATIONPROFILE
DETAIL
NOTES:
A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.
B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.
IMP WALL PANELS COMMERCIAL - INDUSTRIAL
HORIZON WALL PANEL PROFILE IMP-200 JAN 6/21 A
42" COVERAGE
4" TYP.
1 8
"
INTERIOR FACING (MESA)
HORIZON WALL PANEL
WIDTH: 42"
PROFILE: MESA/MESA
INSULATION THICKNESS: 2", 3", 4", 5", 6"
EXTERIOR FACING: 22ga, 24ga, 26ga
INTERIOR FACING: 22ga, 24ga, 26ga
AVAILABLE FINISHES: SMOOTH, LIGHT EMBOSSED/SMOOTH, LIGHT EMBOSSED
INSULATION
EXTERIOR FACING (MESA)
VARIES
SEE SHEET IMP-202 FOR WALL PANEL SIDELAP CONNECTION
DISCLAIMER
THE DETAILS ARE PROVIDED FOR REFERENCE AND AS A GUIDELINE TO INDUSTRY ACCEPTED PRACTICES FOR SIMPLE BUILDING CONDITIONS. THESE DETAILS DO NOT ADDRESS ALL BUILDING
TYPES, CONDITIONS OR DESIGN. THE DETAILS MUST BE CHECKED FOR SUITABILITY AND MODIFIED BASED ON THE PROJECTS INTENDED USE, LOCATION, AND DESIGN LOADS.
A QUALIFIED DESIGN PROFESSIONAL SHOULD BE CONSULTED TO ENSURE MATERIALS, PRODUCTS, AND DESIGN COMPLY WITH APPLICABLE CODES, REGULATIONS, AND STANDARDS. THIS
INCLUDES CORRECT PLACEMENT OF SEALANTS, LOCATION OF AIR/VAPOUR BARRIERS AND PROJECT SPECIFIC DESIGN LOADS REQUIRED BY CODE TO MEET THE REQUIREMENTS FOR THE LOCAL
AUTHORITES HAVING JURISDICTION.
STRUCTURAL SUPPORTS AND CONNECTIONS ARE SHOWN FOR ILLUSTRATION PURPOSES ONLY. CONSTRUCTION DRAWINGS GOVERN OVER THESE DETAILS.
ARTSPAN CONTINUES TO REFINE AND IMPROVE BASED ON CHANGES TO THE INDUSTRY. ARTSPAN AND ITS AFFILIATED COMPANIES AND SUPPLIERS RESERVE THE RIGHT TO CHANGE DETAILS,
SPECIFICATIONS, DESIGNS, OR PRODUCTS AT ANY TIME. PLEASE CONTACT ARTSPAN OR YOUR LOCAL REPRESENTATIVE FOR THE LATEST INFORMATION AVAILABLE.
SCREWLOCATION
REV.SHT. DATE
APPLICATIONPROFILE
DETAIL
NOTES:
A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.
B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.
IMP WALL PANELS COMMERCIAL - INDUSTRIAL
EDGE WALL PANEL PROFILE IMP-200A JAN 6/21 A
42" COVERAGE
INTERIOR FACING (MESA)
INSULATION
EXTERIOR FACING (FLAT)
VARIES
EDGE WALL PANEL
WIDTH: 42"
PROFILE: FLAT/MESA
INSULATION THICKNESS: 2", 3", 4", 5", 6"
EXTERIOR FACING: 22ga, 24ga, 26ga
INTERIOR FACING: 22ga, 24ga, 26ga
AVAILABLE FINISHES: EXTERIOR: SMOOTH, LIGHT EMBOSSED, HEAVY EMBOSSED. INTERIOR: SMOOTH, LIGHT EMBOSSED.
SEE SHEET IMP-202 FOR WALL PANEL SIDELAP CONNECTION
DISCLAIMER
THE DETAILS ARE PROVIDED FOR REFERENCE AND AS A GUIDELINE TO INDUSTRY ACCEPTED PRACTICES FOR SIMPLE BUILDING CONDITIONS. THESE DETAILS DO NOT ADDRESS ALL BUILDING
TYPES, CONDITIONS OR DESIGN. THE DETAILS MUST BE CHECKED FOR SUITABILITY AND MODIFIED BASED ON THE PROJECTS INTENDED USE, LOCATION, AND DESIGN LOADS.
A QUALIFIED DESIGN PROFESSIONAL SHOULD BE CONSULTED TO ENSURE MATERIALS, PRODUCTS, AND DESIGN COMPLY WITH APPLICABLE CODES, REGULATIONS, AND STANDARDS. THIS
INCLUDES CORRECT PLACEMENT OF SEALANTS, LOCATION OF AIR/VAPOUR BARRIERS AND PROJECT SPECIFIC DESIGN LOADS REQUIRED BY CODE TO MEET THE REQUIREMENTS FOR THE LOCAL
AUTHORITES HAVING JURISDICTION.
STRUCTURAL SUPPORTS AND CONNECTIONS ARE SHOWN FOR ILLUSTRATION PURPOSES ONLY. CONSTRUCTION DRAWINGS GOVERN OVER THESE DETAILS.
ARTSPAN CONTINUES TO REFINE AND IMPROVE BASED ON CHANGES TO THE INDUSTRY. ARTSPAN AND ITS AFFILIATED COMPANIES AND SUPPLIERS RESERVE THE RIGHT TO CHANGE DETAILS,
SPECIFICATIONS, DESIGNS, OR PRODUCTS AT ANY TIME. PLEASE CONTACT ARTSPAN OR YOUR LOCAL REPRESENTATIVE FOR THE LATEST INFORMATION AVAILABLE.
SCREWLOCATION
REV.SHT. DATE
APPLICATIONPROFILE
DETAIL
NOTES:
A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.
B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.
IMP WALL PANELS COMMERCIAL - INDUSTRIAL
WALL PANEL INSTALLATION - SEQUENCE 1 IMP-201 JAN 6/21 A
NON-SKINNING BUTYL [SL05]
EAVE/RAKE FRAMING
INTERMEDIATE FRAMING
INSIDE CORNER FLASHING
NON-SKINNING BUTYL [SL05]
BASE FRAMING
BASE TRIM [TR01-01-_T]
NON-SKINNING BUTYL [SL05]
REV.SHT. DATE
APPLICATIONPROFILE
DETAIL
NOTES:
A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.
B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.
IMP WALL PANELS COMMERCIAL - INDUSTRIAL
WALL PANEL INSTALLATION - SEQUENCE 2 IMP-201A JAN 6/21 A
PUSH TOP OF PANEL AGAINST
UPPER FRAMING MEMBER
SET BOTTOM OF PANEL ON BASE FLASHING
NOTE:
- FIELD CUT PANEL TO DESIRED WIDTH.
REV.SHT. DATE
APPLICATIONPROFILE
DETAIL
NOTES:
A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.
B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.
IMP WALL PANELS COMMERCIAL - INDUSTRIAL
WALL PANEL INSTALLATION - SEQUENCE 3 IMP-201B JAN 6/21 A
SECURE TOP OF PANEL
WITH CLIPS AND SCREWS
ALIGN PANEL EDGE
WITH CORNER LINE
CORNER PANEL
SECURE EDGE OF PANEL
WITH SELF-DRILLING SCREWS
PLUMB PANEL WITH LEVEL
INSTALL CLIPS AND SCREWS AT ALL
INTERMEDIATE SUPPORTS (IF APPLICABLE)
SECURE BOTTOM OF PANEL WITH CLIPS AND SCREWS
REV.SHT. DATE
APPLICATIONPROFILE
DETAIL
NOTES:
A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.
B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.
IMP WALL PANELS COMMERCIAL - INDUSTRIAL
WALL PANEL INSTALLATION - SEQUENCE 4 IMP-201C JAN 6/21 A
MARRIAGE BEAD SEALANT (AT EAVE AND BASE)
NON-SKINNING BUTYL [SL05]PUSH TOP OF PANEL AGAINST
UPPER FRAMING MEMBER
INSTALLED PANEL
PRE-INSTALLED JOINT SEALANT
SET CLEARANCE BETWEEN PANELS
SET BOTTOM OF PANEL ON BASE FLASHING
NEXT PANEL
REV.SHT. DATE
APPLICATIONPROFILE
DETAIL
NOTES:
A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.
B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.
IMP WALL PANELS COMMERCIAL - INDUSTRIAL
WALL PANEL INSTALLATION - SEQUENCE 5 IMP-201D JAN 6/21 A
SLIDE PANEL OVER TO FULLY
ENGAGE JOINT OF INSTALLED PANEL
INSTALLED PANEL
PUSH BOTTOM OF PANEL TO
ENGAGE JOINT OF INSTALLED PANEL
NEXT PANEL
REV.SHT. DATE
APPLICATIONPROFILE
DETAIL
NOTES:
A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.
B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.
IMP WALL PANELS COMMERCIAL - INDUSTRIAL
WALL PANEL INSTALLATION - SEQUENCE 6 IMP-201E JAN 6/21 A
PLUMB PANEL WITH LEVEL
INSTALL CLIPS AND SCREWS AT ALL
INTERMEDIATE SUPPORTS (IF APPLICABLE)
SECURE TOP OF PANEL
WITH CLIPS AND SCREWS
INSPECT GAP TO
ENSURE TIGHT FIT
INSTALLED PANEL
SECURE BOTTOM OF PANEL WITH CLIPS AND SCREWS
REV.SHT. DATE
APPLICATIONPROFILE
DETAIL
NOTES:
A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.
B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.
IMP WALL PANELS COMMERCIAL - INDUSTRIAL
WALL PANEL SIDELAP IMP-202 JAN 6/21 A
VISUALLY INSPECT PANEL JOINT TO
ENSURE SEAM IS EVENLY CLOSED WITH
AN APPROX. 1/8" (3mm) GAP
NOTE:
- AT STRUCTURAL GIRT USE STRUCTURAL FASTENER (FST7-5x_ - SD5-#14 x _" HW 3/8" SIDELAP)
- BEAD OF NON-SKINNING BUTYL [SL05] IS TO BE 3/8" UNLESS NOTED OTHERWISE.
- IF SEALANT RUNS OUT OF JOINT ENSURE IT IS CLEANED OFF THE PANEL IMMEDIATELY.
MINIMUM (3) FASTENERS
(FST7-3x_ - SD3-#14x_")
(TYPE PER ENGINEERING DESIGN)
EXTERIOR FACE
INTERIOR FACE
WALL GIRT
(BY FRAMING SUPPLIER)
NON-SKINNING BUTYL [SL05]
WALL PANEL CLIP [CF01]
INSULATED METAL WALL PANEL
REV.SHT. DATE
APPLICATIONPROFILE
DETAIL
NOTES:
A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.
B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.
IMP WALL PANELS COMMERCIAL - INDUSTRIAL
PANEL BASE CONNECTION IMP-203 JAN 6/21 A
VARIES
3 8
"
CONCRETE ANCHORS (BY OTHERS)
NON-SKINNING BUTYL [SL05] WITH MARRIAGE
BEAD TO INTERIOR PANEL JOINT.
3" M
IN
.
BASE ANGLE
(BY FRAMING SUPPLIER)
1/4"x7/8" BUTYL TAPE [SL03]
BASE TRIM [TR01-01-_T]
1/8"Ø X 1/2" STAINLESS STEEL
RIVET @ 16"(406mm) O/C
COVER TRIM [TR10-01]
INSULATED METAL WALL PANEL
WALL PANEL CLIP [CF01]
MINIMUM 3 FASTENERS (FST7-3x_)
BASE SEALANT
(BY FRAMING SUPPLIER)
REV.SHT. DATE
APPLICATIONPROFILE
DETAIL
NOTES:
A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.
B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.
IMP WALL PANELS COMMERCIAL - INDUSTRIAL
PANEL BASE CONNECTION W/ INSULATION IMP-203A JAN 6/21 A
VARIES
CONCRETE ANCHORS
(BY OTHERS)
NON-SKINNING BUTYL [SL05] WITH MARRIAGE
BEAD TO INTERIOR PANEL JOINT.
BASE ANGLE
(BY FRAMING SUPPLIER)
BASE SEALANT
(BY FRAMING SUPPLIER)
MINIMUM 3 FASTENERS [FST7-3x_]
WALL PANEL CLIP [CF01]
INSULATED METAL WALL PANEL
COVER TRIM [TR10-01]
1/8"Ø x 1/2" STAINLESS STEEL
RIVET @ 16"(406mm) O/C
BASE TRIM [TR01-01-_T]
INSULATION
(BY OTHERS)
1/4"x7/8" BUTYL TAPE [SL03]
REV.SHT. DATE
APPLICATIONPROFILE
DETAIL
NOTES:
A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.
B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.
IMP WALL PANELS COMMERCIAL - INDUSTRIAL
OUTSIDE CORNER IMP-204 JAN 6/21 A
VARIES
VARIES
WALL GIRT
(BY FRAMING SUPPLIER)
FILLER ANGLE
(BY FRAMING SUPPLIER)
INSULATED WALL PANEL
THRU FASTENER
1/4-14 x _" - DP3-SQ3 [FST5-3x_]
(AS REQUIRED FOR WIND LOADING)
TO REDUCE THERMAL TRANSFER,
REMOVE INNER LAYER OF STEEL
IN THIS AREA
FIELD INSTALLED INFILL
FILLER INSULATION AS REQUIRED
(BY OTHERS)
OUTSIDE CORNER TRIM
[TR04-02-_T]
SUPPORT ANGLE
(BY FRAMING SUPPLIER)
NON-SKINNING BUTYL [SL05]
INSULATED WALL PANEL
THRU FASTENER 1/4-14 x _" - DP3-SQ3
[FST5-3x_] (AS REQUIRED FOR WIND LOADING)
NOTE:
- FIELD CUT STARTING PANEL AND ENDING PANEL AS REQUIRED AT CORNER TRANSITION.
- SEALER IN THE OUTER GROOVE OF THE WALL PANEL AND BEHIND THE OUTER TRIMS IS ONLY
REQUIRED IN WET LOCATIONS AND WHERE A REVERSE VAPOUR BARRIER IS REQUIRED.
SEE BUILDING SPECIFIC DRAWINGS.
3/16"x7/8" BUTYL TAPE [SL02]
3/16"x7/8" BUTYL TAPE [SL02]
REV.SHT. DATE
APPLICATIONPROFILE
DETAIL
NOTES:
A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.
B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.
IMP WALL PANELS COMMERCIAL - INDUSTRIAL
OUTSIDE CORNER IMP-204A JAN 6/21 A
VARIES
VARIES
WALL GIRT
(BY FRAMING SUPPLIER)
INSULATED WALL PANEL
THRU FASTENER
1/4-14 x _" - DP3-SQ3 [FST5-3x_]
(AS REQUIRED FOR WIND LOADING)
TO REDUCE THERMAL TRANSFER,
REMOVE INNER LAYER OF STEEL
IN THIS AREA
FIELD INSTALLED INFILL
FILLER INSULATION AS REQUIRED
(BY OTHERS)
OUTSIDE CORNER TRIM
[TR04-02-_T]
INSIDE CORNER TRIM [TR04-04-_T]
NON-SKINNING BUTYL [SL05]
INSULATED WALL PANEL
THRU FASTENER 1/4-14 x _" - DP3-SQ3
[FST5-3x_] (AS REQUIRED FOR WIND LOADING)
NOTE:
- FIELD CUT STARTING PANEL AND ENDING PANEL AS REQUIRED AT CORNER TRANSITION.
- SEALER IN THE OUTER GROOVE OF THE WALL PANEL AND BEHIND THE OUTER TRIMS IS ONLY
REQUIRED IN WET LOCATIONS AND WHERE A REVERSE VAPOUR BARRIER IS REQUIRED.
SEE BUILDING SPECIFIC DRAWINGS.
3/16"x7/8" BUTYL TAPE [SL02]
3/16"x7/8" BUTYL TAPE [SL02]
1/8"Ø X 1/2" STAINLESS STEEL RIVET [FST4]@ 16"(406mm) O/C
ATTACHMENT CLIP
(BY FRAMING SUPPLIER)
REV.SHT. DATE
APPLICATIONPROFILE
DETAIL
NOTES:
A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.
B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.
IMP WALL PANELS COMMERCIAL - INDUSTRIAL
INSIDE CORNER IMP-205 JAN 6/21 A
VARIES
INSULATED METAL WALL PANEL
1/8"Ø X 1/2" STAINLESS STEEL RIVET
[FST4] @ 16"(406mm) O/C
THRU FASTENER 1/4-14 x _" - DP3-SQ3
[FST5-3x_] (AS REQUIRED FOR WIND LOADING)
INSIDE CORNER TRIM
[TR04-04]
INSULATED METAL WALL PANEL
NOTE:
- BEAD OF NON-SKINNING BUTYL [SL05] IS TO BE 3/8" UNLESS NOTED OTHERWISE.
- IF SEALANT RUNS OUT OF JOINT ENSURE IT IS CLEANED OFF THE PANEL IMMEDIATELY.
- FIELD CUT STARTING PANEL AND ENDING PANEL AS REQUIRED AT CORNER TRANSITION.
- SEALER IN THE OUTER GROOVE OF THE WALL PANEL AND BEHIND THE OUTER TRIMS IS ONLY REQUIRED IN WET LOCATIONS
WHERE A REVERSE VAPOUR BARRIER IS REQUIRED. SEE BUILDING SPECIFIC DRAWINGS.
TO REDUCE THERMAL TRANSFER,
REMOVE INNER LAYER OF STEEL
IN THIS AREA
NON-SKINNING BUTYL [SL05]
SUPPORT ANGLE (BY FRAMING SUPPLIER)
STRUCTURAL WALL GIRT (BY FRAMING SUPPLIER)
NON-SKINNING BUTYL [SL05]
3/16"x7/8" BUTYL TAPE [SL02]
3/16"x7/8" BUTYL TAPE [SL02]
NON-SKINNING BUTYL [SL05]
VARIES
REV.SHT. DATE
APPLICATIONPROFILE
DETAIL
NOTES:
A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.
B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.
IMP WALL PANELS COMMERCIAL - INDUSTRIAL
INSIDE CORNER IMP-205A JAN 6/21 A
INSULATED METAL WALL PANEL
1/8"Ø X 1/2" STAINLESS STEEL RIVET
[FST4] @ 16"(406mm) O/C
THRU FASTENER 1/4-14 x _" - DP3-SQ3
[FST5-3x_] (AS REQUIRED FOR WIND LOADING)
INSIDE CORNER TRIM
[TR04-04]
INSULATED METAL WALL PANEL
NOTE:
- BEAD OF NON-SKINNING BUTYL [SL05] IS TO BE 3/8" UNLESS NOTED OTHERWISE.
- IF SEALANT RUNS OUT OF JOINT ENSURE IT IS CLEANED OFF THE PANEL IMMEDIATELY.
- FIELD CUT STARTING PANEL AND ENDING PANEL AS REQUIRED AT CORNER TRANSITION.
- SEALER IN THE OUTER GROOVE OF THE WALL PANEL AND BEHIND THE OUTER TRIMS IS ONLY REQUIRED IN WET LOCATIONS
WHERE A REVERSE VAPOUR BARRIER IS REQUIRED. SEE BUILDING SPECIFIC DRAWINGS.
TO REDUCE THERMAL TRANSFER,
REMOVE INNER LAYER OF STEEL
IN THIS AREA
1/8"Ø X 1/2" STAINLESS STEEL RIVET
[FST4] @ 16"(406mm) O/C
STRUCTURAL WALL GIRT (BY FRAMING SUPPLIER)
NON-SKINNING BUTYL [SL05]1/8"Ø X 1/2" STAINLESS STEEL RIVET
[FST4] @ 16"(406mm) O/C
3/16"x7/8" BUTYL TAPE [SL02]
3/16"x7/8" BUTYL TAPE [SL02]
NON-SKINNING BUTYL [SL05]
NON-SKINNING BUTYL [SL05]
OUTSIDE CORNER TRIM
[TR04-02-_T]
REV.SHT. DATE
APPLICATIONPROFILE
DETAIL
NOTES:
A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.
B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.
IMP WALL PANELS COMMERCIAL - INDUSTRIAL
DOOR HEADER IMP-206 JAN 6/21 A
1/4"
VARIES
INSULATED METAL WALL PANEL
WALL PANEL CLIP [CF01]
(2)SD3-#14X_"-HW3/8" SCREWS AT LIGHT GAUGE HEADERS
OR
(2)SD5-#14x_"-HW3/8" SCREWS AT MILL HEADERS
SD3-#14X1"-PC @ 12"(305mm) O/C
HEADER SUPPORT
(BY FRAMING SUPPLIER)
1/8"Ø X 1/2" STAINLESS STEEL
RIVET [FST4] @ 12" (305mm) O/C
CEE COVER TRIM
8" FRAMING [TR10-02-08]
10" FRAMING [TR10-02-10]
NON-SKINNING BUTYL [SL05]
NON-SKINNING BUTYL [SL05] WITH MARRIAGE
BEAD TO INTERIOR PANEL JOINT.
HEADER TRIM
[TR06-01-_T]
NOTE:
- BEAD OF NON-SKINNING BUTYL [SL05] IS TO BE 3/8" UNLESS NOTED OTHERWISE.
- IF SEALANT RUNS OUT OF JOINT ENSURE IT IS CLEANED OFF THE PANEL IMMEDIATELY.
- BEAD OF URETHANE POLYSEAL [SL06] IS TO BE 1/4" MINIMUM. A LARGER BEAD MAY BE USED IF REQUIRED.
REV.SHT. DATE
APPLICATIONPROFILE
DETAIL
NOTES:
A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.
B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.
IMP WALL PANELS COMMERCIAL - INDUSTRIAL
DOOR JAMB IMP-206A JAN 6/21 A
VARIES
NOTE:
- BEAD OF NON-SKINNING BUTYL [SL05] IS TO BE 3/8" UNLESS NOTED OTHERWISE.
- IF SEALANT RUNS OUT OF JOINT ENSURE IT IS CLEANED OFF THE PANEL IMMEDIATELY.
- BEAD OF URETHANE POLYSEAL [SL06] IS TO BE 1/4" MINIMUM. A LARGER BEAD MAY BE USED IF REQUIRED.
1/8"Ø X 1/2" STAINLESS STEEL RIVET [FST4] @ 12" (305mm) O/C
WALL GIRT (BY FRAMING SUPPLIER)
STANDARD DOOR JAMB (BY FRAMING SUPPLIER)
1/4-14 x _"-DP3-SQ3 THRU FASTENER
[FST5-3x_"] @ 24" (610mm) O/C
CEE COVER TRIM
8" FRAMING [TR10-02-08]
10" FRAMING [TR10-02-10]
NON-SKINNING BUTYL [SL05]
JAMB TRIM [TR05-01-_T]
3/16"x7/8" BUTYL TAPE [SL02]
1/8"Ø X 1/2" STAINLESS STEEL RIVET [FST4]
@ 12" (305mm) O/C
INSULATED METAL WALL PANEL
1 1/4" MIN.
1
4
"
VARIES
REV.SHT. DATE
APPLICATIONPROFILE
DETAIL
NOTES:
A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.
B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.
IMP WALL PANELS COMMERCIAL - INDUSTRIAL
WINDOW HEADER IMP-207 JAN 6/21 A
INSULATED METAL WALL PANEL
WALL PANEL CLIP [CF01]
(2)SD3-#14X_"-HW3/8" SCREWS AT LIGHT GAUGE HEADERS
OR
(2)SD5-#14x_"-HW3/8" SCREWS AT MILL HEADERS
SD3-#14X1"-PC BASE(FLAT)
[FST6-3] @ 12"(305mm) O/C
NON-SKINNING BUTYL [SL05]
STRUCTURAL HEADER SUPPORT
(BY FRAMING SUPPLIER)
WINDOW FRAME
(BY OTHERS)
PERIMETER SEALANT
(BY OTHERS)
NON-SKINNING BUTYL [SL05] WITH MARRIAGE
BEAD TO INTERIOR PANEL JOINT.
HEADER TRIM
[TR06-01-_T]
NOTE:
- BEAD OF NON-SKINNING BUTYL [SL05] IS TO BE 3/8" UNLESS NOTED OTHERWISE.
- IF SEALANT RUNS OUT OF JOINT ENSURE IT IS CLEANED OFF THE PANEL IMMEDIATELY.
- BEAD OF URETHANE POLYSEAL [SL06] IS TO BE 1/4" MINIMUM. A LARGER BEAD MAY BE USED IF REQUIRED.
VARIES
REV.SHT. DATE
APPLICATIONPROFILE
DETAIL
NOTES:
A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.
B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.
IMP WALL PANELS COMMERCIAL - INDUSTRIAL
WINDOW JAMB IMP-207A JAN 6/21 A
NOTE:
- BEAD OF NON-SKINNING BUTYL [SL05] IS TO BE 3/8" UNLESS NOTED OTHERWISE.
- IF SEALANT RUNS OUT OF JOINT ENSURE IT IS CLEANED OFF THE PANEL IMMEDIATELY.
- BEAD OF URETHANE POLYSEAL [SL06] IS TO BE 1/4" MINIMUM. A LARGER BEAD MAY BE USED IF REQUIRED.
1/8"Ø X 1/2" STAINLESS STEEL RIVET [FST 4] @ 12"(305mm) O/C
STRUCTURAL WALL GIRT
(BY FRAMING SUPPLIER)
STRUCTURAL WINDOW JAMB (BY FRAMING SUPPLIER)
1/4-14 x _"-DP3-SQ3 THRU FASTENER @ 24"(610mm) O/C
NON-SKINNING BUTYL [SL05]
INSULATED METAL WALL PANEL
1/8"Ø X 1/2" STAINLESS STEEL RIVET [FST4] @ 12"(305mm) O/C
3/16"x7/8" BUTYL TAPE [SL02]
JAMB TRIM [TR05-01-_T]
PERIMETER SEALANT
(BY OTHERS)
WINDOW FRAME
(BY OTHERS)
CEE COVER TRIM
8" FRAMING [TR10-02-08]
10" FRAMING [TR10-02-10]
1 1/4" MIN.
1 2
"
VARIES
REV.SHT. DATE
APPLICATIONPROFILE
DETAIL
NOTES:
A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.
B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.
IMP WALL PANELS COMMERCIAL - INDUSTRIAL
WINDOW SILL IMP-207B JAN 6/21 A
NON-SKINNING BUTYL [SL05]UNDER SILL TRIM.
CEE COVER TRIM
8" FRAMING [TR10-02-08]
10" FRAMING [TR10-02-10]
WINDOW SILL (BY FRAMING SUPPLIER)
(2)SD3-#14X_"-HW3/8" SCREWS AT LIGHT GAUGE HEADERS
OR
(2)SD5-#14x_"-HW3/8" SCREWS AT MILL HEADERS
NON-SKINNING BUTYL [SL05] WITH MARRIAGE
BEAD TO INTERIOR PANEL JOINT.
WALL PANEL CLIP [CF01]
INSULATED METAL
WALL PANEL
1/8"Ø X 1/2" STAINLESS STEEL RIVET [FST4]
@ 12"(305mm) O/C
3/16"x7/8" BUTYL TAPE
[SL02]
WINDOW SILL TRIM
[TR07-01-_T]
PERIMETER SEALANT
(BY OTHERS)
WINDOW FRAME
(BY OTHERS)
REV.SHT. DATE
APPLICATIONPROFILE
DETAIL
NOTES:
A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.
B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.
IMP WALL PANELS COMMERCIAL - INDUSTRIAL
PANEL SIDE JOINT IMP-208 JAN 6/21 A
1" MAX
varies
NOTE:
- BEAD OF NON-SKINNING BUTYL [SL05] IS TO BE 3/8" UNLESS NOTED OTHERWISE.
- IF SEALANT RUNS OUT OF JOINT ENSURE IT IS CLEANED OFF THE PANEL IMMEDIATELY.
1/8"Ø X 1/2" STAINLESS STEEL RIVET
[FST 4] @ 12"(305mm) O/C
JOINT COVER TRIM [TR10-05]
1/4-14 x _"-DP3-SQ3 THRU FASTENER @ 24"(610mm) O/C
(2 PER SUPPORT)
WALL GIRT (BY FRAMING SUPPLIER)
NON-SKINNING BUTYL [SL05]
INSULATED METAL WALL PANEL
EXPANDABLE FOAM INSULATION
(BY OTHERS)
JOINT COVER TRIM [TR10-05]
3/16"x7/8" BUTYL TAPE [SL02]
1/8"Ø X 1/2" STAINLESS STEEL RIVET
[FST4] @ 12" (305mm) O/C
1" MIN
FROM PANEL EDGE
REV.SHT. DATE
APPLICATIONPROFILE
DETAIL
NOTES:
A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.
B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.
IMP WALL PANELS COMMERCIAL - INDUSTRIAL
VERTICAL STACK JOINT IMP-208A JAN 6/21 A
VARIES
1/2"
NOTE:
- BEAD OF NON-SKINNING BUTYL [SL05] IS TO BE 3/8" UNLESS NOTED OTHERWISE.
- IF SEALANT RUNS OUT OF JOINT ENSURE IT IS CLEANED OFF THE PANEL IMMEDIATELY.
- BEAD OF URETHANE POLYSEAL [SL06] IS TO BE 1/4" MINIMUM. A LARGER BEAD MAY BE USED IF REQUIRED.
WALL PANEL CLIP
[CF01]
INSULATED METAL WALL PANEL
NON-SKINNING BUTYL [SL05]
SD3-#14x1"-PC BASE (FLAT)
[FST6-3] @ 5'-0"(1524mm) O/C
SUPPORT ANGLE WITH SEALANT
(BY FRAMING SUPPLIER)
WALL GIRT
(BY FRAMING SUPPLIER)
1/8"Ø x 1/2" STAINLESS STEEL RIVET
[FST4] @ 16"(406mm) O/C
COVER TRIM [TR10-01]
STACK JOINT TRIM [TR01-03-_T]
NON-SKINNING BUTYL [SL05]
3/16"x7/8" BUTYL TAPE [SL02]
1/8"Ø X 1/2" STAINLESS STEEL RIVET
[FST 4] @ 12"(305mm) O/C
INSULATED METAL WALL PANEL
NON-SKINNING BUTYL [SL05] WITH MARRIAGE
BEAD TO INTERIOR PANEL JOINT.
MINIMUM (3) FASTENERS [FST7-5x_"]
(TYPE PER ENGINEERING DESIGN)
NON-SKINNING BUTYL [SL05] WITH MARRIAGE
BEAD TO INTERIOR PANEL JOINT.
WALL PANEL CLIP [CF01]
2
"
T
R
I
M
L
A
P
2
"
T
R
I
M
L
A
P
REV.SHT. DATE
APPLICATIONPROFILE
DETAIL
NOTES:
A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.
B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.
IMP WALL PANELS COMMERCIAL - INDUSTRIAL
TRIM END LAP - BASE IMP-209 JAN 6/21 A
NOTE:
- RIVET OR STITCH SCREW AS NECESSARY.
FIELD NOTCH HEM(S) AS REQUIRED
2 BEADS OF NON-SKINNING BUTYL [SL05]
2"
TRIM
LAP
REV.SHT. DATE
APPLICATIONPROFILE
DETAIL
NOTES:
A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.
B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.
IMP WALL PANELS COMMERCIAL - INDUSTRIAL
TRIM END LAP - CORNER IMP-209A JAN 6/21 A
NOTE:
- RIVET OR STITCH SCREW AS NECESSARY.
FIELD NOTCH HEM(S) AS REQUIRED
2 BEADS OF NON-SKINNING BUTYL [SL05]
2"
TRIM
LAP
REV.SHT. DATE
APPLICATIONPROFILE
DETAIL
NOTES:
A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.
B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.
IMP WALL PANELS COMMERCIAL - INDUSTRIAL
TRIM END LAP - TWO PIECE HEAD IMP-209B JAN 6/21 A
2
"
T
R
I
M
L
A
P
2
"
T
R
I
M
L
A
P
NOTE:
- RIVET OR STITCH SCREW AS NECESSARY.
FIELD NOTCH HEM(S) AS REQUIRED
2 BEADS OF NON-SKINNING BUTYL [SL05]
REV.SHT. DATE
APPLICATIONPROFILE
DETAIL
NOTES:
A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.
B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.
IMP WALL PANELS COMMERCIAL - INDUSTRIAL
TRIM END LAP - TWO PIECE JAMB IMP-209C JAN 6/21 A
2"
TRIM
LAP
2"
TRIM
LAP
NOTE:
- RIVET OR STITCH SCREW AS NECESSARY.
FIELD NOTCH HEM(S) AS REQUIRED
2 BEADS OF NON-SKINNING BUTYL [SL05]
REV.SHT. DATE
APPLICATIONPROFILE
DETAIL
NOTES:
A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.
B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.
IMP WALL PANELS COMMERCIAL - INDUSTRIAL
TRIM END LAP - SILL IMP-209D JAN 6/21 A
2
"
T
R
I
M
L
A
P
2
"
T
R
I
M
L
A
P
NOTE:
- RIVET OR STITCH SCREW AS NECESSARY.
FIELD NOTCH HEM(S) AS REQUIRED
2 BEADS OF NON-SKINNING BUTYL [SL05]
REV.SHT. DATE
APPLICATIONPROFILE
DETAIL
NOTES:
A. DETAILS ARE FOR GUIDELINES ONLY, AND MAY NOT BE SUITABLE FOR ALL BUILDING DESIGNS AND CONDITIONS.
B. SCREW LENGTHS MAY VARY PER CUSTOMER REQUEST. #12-14x1", #12-14x1 1/2", #12-14x2", #12-14x3" ARE AVAILABLE.
IMP WALL PANELS COMMERCIAL - INDUSTRIAL
TRIM END LAP - SILL IMP-209E JAN 6/21 A
1
2
3
4
5
1
2
3
4
5
TRIM INSTALLATION SEQUENCE:
INTERIOR JAMB TRIMS
INTERIOR HEAD TRIM WITH TABS BENT DOWN, NOTCHED
SILL TRIM WITH TABS BENT UP, NOTCHED
EXTERIOR JAMB TRIMS
EXTERIOR HEAD TRIM
EXTERIOR JAMB TRIM
EXTERIOR HEAD TRIM
INTERIOR HEAD TRIM W/ TABS BENT DOWN
SILL TRIM WITH TABS BENT UP
INTERIOR JAMB TRIM
NON-SKINNING BUTYL[SL05]
URETHANE POLYSEAL [SL06]
URETHANE END DAM
FIELD CUT/NOTCH CAP TRIM AT
CORNERS TO ALLOW FOR LAP
FIELD CUT/NOTCH CAP TRIM AT
CORNERS TO ALLOW FOR LAP
EXPOSED SEALANT (BY FRAMING SUPPLIER)