Download - Pump control
![Page 1: Pump control](https://reader031.vdocument.in/reader031/viewer/2022020710/55634d36d8b42aed538b49e4/html5/thumbnails/1.jpg)
02-01-10 1
System REPORT
WWTP Waterworks
![Page 2: Pump control](https://reader031.vdocument.in/reader031/viewer/2022020710/55634d36d8b42aed538b49e4/html5/thumbnails/2.jpg)
02-01-10 2
AQUALEVEL®
![Page 3: Pump control](https://reader031.vdocument.in/reader031/viewer/2022020710/55634d36d8b42aed538b49e4/html5/thumbnails/3.jpg)
02-01-10 3
Pump Control PC2
control of 2 pumps
input: 4 to 20 mA
13 bit resolution
digital level setting
pump alternation
3 potential free relays
AQUALEVEL®
![Page 4: Pump control](https://reader031.vdocument.in/reader031/viewer/2022020710/55634d36d8b42aed538b49e4/html5/thumbnails/4.jpg)
02-01-10 4
AQUALEVEL®
![Page 5: Pump control](https://reader031.vdocument.in/reader031/viewer/2022020710/55634d36d8b42aed538b49e4/html5/thumbnails/5.jpg)
02-01-10 5
AQUALEVEL®
Pump Control PC4
control of 4 pumps
input: 4 to 20 mA
digital level setting
pump alternation
5 digital outlets
1 analog inlet (pressure switch)
RS 232 and telemetry option
![Page 6: Pump control](https://reader031.vdocument.in/reader031/viewer/2022020710/55634d36d8b42aed538b49e4/html5/thumbnails/6.jpg)
02-01-10 6
AQUALEVEL®
![Page 7: Pump control](https://reader031.vdocument.in/reader031/viewer/2022020710/55634d36d8b42aed538b49e4/html5/thumbnails/7.jpg)
02-01-10 7
Controls 4 pumps with alternationIn /out-flow calculationPump capacity calculationOverflow calculationStores number of starts and running hours pumped volume and overflowCommunicates with other systems
Controller Series PC4with RDT-APS computer software
Application
For controlling pumping stations and communicating within a telemetry system
![Page 8: Pump control](https://reader031.vdocument.in/reader031/viewer/2022020710/55634d36d8b42aed538b49e4/html5/thumbnails/8.jpg)
02-01-10 8
PANEL VERSION
![Page 9: Pump control](https://reader031.vdocument.in/reader031/viewer/2022020710/55634d36d8b42aed538b49e4/html5/thumbnails/9.jpg)
02-01-10 9
Enclosures for Wall Mounting(with space for backup battery and modem)
![Page 10: Pump control](https://reader031.vdocument.in/reader031/viewer/2022020710/55634d36d8b42aed538b49e4/html5/thumbnails/10.jpg)
02-01-10 10
Hydrostatic Level Sensor HSR
range: 3.5 or 10 m WC
output 4 to 20 mA
PVC encapsulated
silicate glass membrane
piezoresistive type
low cost
AQUALEVEL®
![Page 11: Pump control](https://reader031.vdocument.in/reader031/viewer/2022020710/55634d36d8b42aed538b49e4/html5/thumbnails/11.jpg)
02-01-10 11
Hydrostatic Level Sensor HSC
range: 4 or 10 m WC
output 4 to 20 mA
stainless steel body
ceramic membrane
capacitive type
high precision
EEx Zone 1 & 2 (0 with Zener barrier)
AQUALEVEL®
![Page 12: Pump control](https://reader031.vdocument.in/reader031/viewer/2022020710/55634d36d8b42aed538b49e4/html5/thumbnails/12.jpg)
02-01-10 12
Mounting Level Sensors HSC
![Page 13: Pump control](https://reader031.vdocument.in/reader031/viewer/2022020710/55634d36d8b42aed538b49e4/html5/thumbnails/13.jpg)
02-01-10 13
![Page 14: Pump control](https://reader031.vdocument.in/reader031/viewer/2022020710/55634d36d8b42aed538b49e4/html5/thumbnails/14.jpg)
02-01-10 14
Pressure Sensor HPC
ranges: 0.1 up to 20 bar
output 4 to 20 mA
stainless steel body
ceramic membrane
capacitive type
high precision
stud: 1/2” or 1 1/2”
AQUALEVEL®
![Page 15: Pump control](https://reader031.vdocument.in/reader031/viewer/2022020710/55634d36d8b42aed538b49e4/html5/thumbnails/15.jpg)
02-01-10 15
Installation Example
AQUALEVEL® HPCPressure sensor
AQUALEVEL® HSR or HSCLevel sensor
![Page 16: Pump control](https://reader031.vdocument.in/reader031/viewer/2022020710/55634d36d8b42aed538b49e4/html5/thumbnails/16.jpg)
02-01-10 17
impact & shock resistant
mercury free-environmentally friendly
completely sealed
can be used in EEx applications, with an intrinsically safe relay
FeaturesAQUALEVEL® KS
![Page 17: Pump control](https://reader031.vdocument.in/reader031/viewer/2022020710/55634d36d8b42aed538b49e4/html5/thumbnails/17.jpg)
02-01-10 18
automatic level control in pump stations
overflow protection or dry running protection
allows indication of max / min levels
control of motorised valves
acts as a signal or alarm unit
ApplicationsAQUALEVEL® KS
![Page 18: Pump control](https://reader031.vdocument.in/reader031/viewer/2022020710/55634d36d8b42aed538b49e4/html5/thumbnails/18.jpg)
02-01-10 19
AQUALEVEL® KS
![Page 19: Pump control](https://reader031.vdocument.in/reader031/viewer/2022020710/55634d36d8b42aed538b49e4/html5/thumbnails/19.jpg)
02-01-10 30
Plug in telemetry system with process visualisationmaps with locationsnetwork mapsvisualization of pumping stationsstatistic evaluationgraphs
Access-data format for easy evaluations
AQUALEVEL®
![Page 20: Pump control](https://reader031.vdocument.in/reader031/viewer/2022020710/55634d36d8b42aed538b49e4/html5/thumbnails/20.jpg)
02-01-10 31
Plug in telemetry system with process visualisationoperation, monitoring and control message indication: text,
pictures, audible signalsworking programme management up to 16 levelsuser authorisation and managementmultilingual applicationsVB scriptextensive symbol libraryreport functionstransmission of SMS, Fax, E-maillogging of events
AQUALEVEL®
![Page 21: Pump control](https://reader031.vdocument.in/reader031/viewer/2022020710/55634d36d8b42aed538b49e4/html5/thumbnails/21.jpg)
02-01-10 32
Modem
Modem
Modem
Modem
Printer
Telephone Network
GSM
Modem
Modem
Control Engineering Systems
ALARM GSM/SMS
![Page 22: Pump control](https://reader031.vdocument.in/reader031/viewer/2022020710/55634d36d8b42aed538b49e4/html5/thumbnails/22.jpg)
02-01-10 34
EXPLANATION OF CODESPC2PC4
RS232 (COM1/modem)HSR 3,5/10 mHSC 3,5/10 m
![Page 23: Pump control](https://reader031.vdocument.in/reader031/viewer/2022020710/55634d36d8b42aed538b49e4/html5/thumbnails/23.jpg)
02-01-10 38
2 SOFTWARES
RDT SPVREPORT
![Page 24: Pump control](https://reader031.vdocument.in/reader031/viewer/2022020710/55634d36d8b42aed538b49e4/html5/thumbnails/24.jpg)
02-01-10 39
Configuration tool RDT-SPV
• On-line & off-line configuration
• All settings can be made remotely
• Status readout• Alarm readout• Configuration up/down
load
![Page 25: Pump control](https://reader031.vdocument.in/reader031/viewer/2022020710/55634d36d8b42aed538b49e4/html5/thumbnails/25.jpg)
02-01-10 40
Configuration tool RDT-SPV
![Page 26: Pump control](https://reader031.vdocument.in/reader031/viewer/2022020710/55634d36d8b42aed538b49e4/html5/thumbnails/26.jpg)
02-01-10 41
![Page 27: Pump control](https://reader031.vdocument.in/reader031/viewer/2022020710/55634d36d8b42aed538b49e4/html5/thumbnails/27.jpg)
02-01-10 42
![Page 28: Pump control](https://reader031.vdocument.in/reader031/viewer/2022020710/55634d36d8b42aed538b49e4/html5/thumbnails/28.jpg)
02-01-10 43
![Page 29: Pump control](https://reader031.vdocument.in/reader031/viewer/2022020710/55634d36d8b42aed538b49e4/html5/thumbnails/29.jpg)
02-01-10 44
![Page 30: Pump control](https://reader031.vdocument.in/reader031/viewer/2022020710/55634d36d8b42aed538b49e4/html5/thumbnails/30.jpg)
02-01-10 46
AQUALEVEL® RDT - APV
![Page 31: Pump control](https://reader031.vdocument.in/reader031/viewer/2022020710/55634d36d8b42aed538b49e4/html5/thumbnails/31.jpg)
02-01-10 50
A controller made specifically for the monitoring and controlling of pumps, valves, etc
Control Computer
Application
WWTP
Waterworks
Pumping station network
Booster pumping stations
With max. I/O units it handles:80 Digital and 20 Analog in signals40 Digital and 5 Analog out signals
![Page 32: Pump control](https://reader031.vdocument.in/reader031/viewer/2022020710/55634d36d8b42aed538b49e4/html5/thumbnails/32.jpg)
02-01-10 51
AutomationAutomation
cπd CPU30Centralenhet
cπd OPIOperatörspanel
Centipede-serien
cπd XPI/O-enhet
Applications:
Water treatment
WWTP
Pumpingstations
Pressure boosting
units
Remote control
![Page 33: Pump control](https://reader031.vdocument.in/reader031/viewer/2022020710/55634d36d8b42aed538b49e4/html5/thumbnails/33.jpg)
02-01-10 52
System REPORT