Made in Italy
Quality and performanceto your industrial space
Street
Industrial
Sports
Tunnels
Commercial
Urban
Architectural
Photovoltaic
Large areas
GHOST - R
ADVA
NCED EOS PROTECTION SYSTEM
The most advanced LED technologyunder a traditional cover
Halley
Focus:The electrical connection can be effected without the need to open the unit, thanks to the external connector.
Rapid connection LED technology Made in Italy Quality
Main features Advantages
Long Life Span:The extruded aluminium dissipator, with wide cooling Fins guarantees long Life Span to Diodes. 10 Years Guarantee on all metal components.
Maximum Efficiency and Resistance:The distribution of the LEDs on the extruded side and the Active cooling system guarantee protection fromoverheating and the maximum efficiency of the fixture.
IP68 axial fans:They guarantee total protection, inside particularly dirty locations, against dust and water (in case of product cleaning with strong water jets)
Fixture composition:Grey Color techno polymer with inner screen on 2 mm SMMA.
Reflector:Anodized aluminium. It performs the function of optical unit.
Life Span (L70B20): >80.000 h.
Mounting:Equipped with hanging hook. Possibility of recessed mounting through a special Kit.
Eleva - 2016 - V. 2Pag. 52
Halley
Technical features
STANDARD COLOR
DETAILS
APPLICATIONS
BODY: Anthracite Grey RAL7024 REFLECTOR: Anodized grey
IP66 connectorsfor power source
Hanging hook
UL 94 V-0techno polymer
Power compartmentsilicon gasket
High efficiencyelectronic power
supply
6061-T6 aluminiumalloy extruded
Multi-chip LED module+ EOS protection
Protected activecooling againstwater and dust(IP68 axial fans)
Optica unitsilicon gasket
Termal double sided adesivewith high electrical insulationpower
UL 94 V-0techno polymer
SMMAtransparent glass
Reflector onanodized aluminium
Electronicpart for fanscontrol • Technopolymer body
•
• Tempered glass optional
• Switch on-off time < 1 s
• CCT Standard: N (4000K ± 300K)
CCT optional: W (3000K ± 300K)
• Power factor: > 0.95
Anodized reflector
• SMMA transparent or frosted
(optional) screen
CCT optional: C (5000K ± 300K)
•
η >130lm/W @ 850mA
• Lifetime: 80.000 hrs
• Optional dimmable Driver
Luminous source efficiency
• CRI Standard: 70...79
CRI optional: 80...89
• LED quadrichip Lumileds
• Industrial areas and
warehouses
• Commercial areas
• Indoor sport facilities
Pag. 53Eleva - 2016 - V. 2
Halley
Halley 90
Halley 00
(Ø) d2
h2
(Ø) d2
(Ø) d1(Ø) d
2
(Ø) d1
h1
FEATURES
• Standard
• Optional
70...794.000 K 11,5 Kg80.000 h
LEDF220
240+45°C
-20°C
125280 3.000 K 5.000 K
IP65 IP65 IK08
d = d =h =h =
482 mm323 mm418 mm218 mm
HALLEY-6H: w = 8,0 KgHALLEY-10H: w = 8,0 KgHALLEY-16H: w = 8,5 KgHALLEY-22H: w = 10,0 KgHALLEY-24H: w = 11,0 KgHALLEY-24X:
•••••• w = 11,5 Kg
• SIZE
• WEIGHT
2
1
1
2 HALLEY-6H-N[°°]-GR 50 6.480 6 4.000 700
HALLEY-6H-C[°°]-GR 50 6.480 6 5.000 700
HALLEY-6H-W[°°]-GR 50 5.400 6 3.000 700
HALLEY-10H-N[°°]-GR 84 10.800 10 4.000 700
HALLEY-10H-C[°°]-GR 84 10.800 10 5.000 700
HALLEY-10H-W[°°]-GR 84 9.000 10 3.000 700
HALLEY-16H-N[°°]-GR 134 17.280 16 4.000 700
HALLEY-16H-C[°°]-GR 134 17.280 16 5.000 700
HALLEY-16H-W[°°]-GR 134 14.400 16 3.000 700
HALLEY-22H-N[°°]-GR 184 23.760 22 4.000 700
HALLEY-22H-C[°°]-GR 184 23.760 22 5.000 700
HALLEY-22H-W[°°]-GR 184 19.800 22 3.000 700
HALLEY-24H-N[°°]-GR 200 25.960 24 4.000 700
HALLEY-24H-C[°°]-GR 200 25.960 24 5.000 700
HALLEY-24H-W[°°]-GR 200 21.600 24 3.000 700
HALLEY-24X-N[°°]-GR 245 30.480 24 4.000 850
HALLEY-24X-C[°°]-GR 245 30.480 24 5.000 850
HALLEY-24X-W[°°]-GR 245 25.440 24 3.000 850
CCT[K]
No.LED
F[lm]
IF [mA]Code P
[W]
ITEM CODE COMPOSITION
[°°] = 90 - 00
Eleva - 2016 - V. 2Pag. 54
[00] - Symmetric 115°
C0-C180 C90-C2700°
90° 240
[90] - Symmetric 80°
C0-C180 C90-C2700°
90° 480
Halley
• SYMMETRIC
Photometric features
Energy saving
0
75 W
150 W
225 W
300 W
374 W
450 WTraditional 400W
H24H
0
50 W
100 W
150 W
200 W
250 W
300 W
52 %
Traditional 250W
H16H
53 %Actual
Consumption418 W
ActualConsumption
200 W
ActualConsumption
285 W
ActualConsumption
134 W
Power Reduction
Power Reduction
0
30 W
60 W
90 W
120 W
150 W
180 WTraditional 150W
H10H
0
20 W
40 W
60 W
80 W
100 W
120 W
50 %
Traditional 100W
H6H
56 %Actual
Consumption168 W
ActualConsumption
84 W
ActualConsumption
114 W
ActualConsumption
50 W
Power Reduction Power Reduction
Cone diagram H22H
8
10
12
244•0,51
Em [Lux]•U0 h[m] h[m] h[m]
h[m] h[m] h[m]
[m]
138•0,54
89•0,57
8
10
12
184W [m] [m]
[m] [m] [m]
Cone diagram H24H
8
10
12
267•0,51
Em [Lux]•U0
151•0,54
97•0,57
8
10
12
200W
Cone diagram H24X
8
10
12
313•0,51
Em [Lux]•U0
177•0,54
114•0,57
8
10
12
245W
Cone diagram H6H
8
12
16
70•0,43
Em [Lux]•U0
31•0,42
17•0,43
4
6
8
50W
Cone diagram H10H
8
12
16
117•0,43
Em [Lux]•U0
51•0,42
28•0,43
4
6
8
84W
Cone diagram H16H
8
12
16
188•0,43
Em [Lux]•U0
82•0,42
45•0,43
4
6
8
134W
80° 80° 80°
115° 115° 115°
Halley 90
Halley 00
Pag. 55Eleva - 2016 - V. 2
Halley
Mounting accessories
KM-H-INC / Recessed mounting
This mounting kit is particularly suitable in case of false ceiling.(Example: airport, service station, industrial structures)
Sectional viewAesthetic mask
False ceiling
Kit and Optional
KH-EMEmergency Kit
KH-D/SSMMA frosted diffusor
Halley LED Box
Adjustment bracket
Built in Emergency kit available (optional):4 LED @ 100 mA - 5W - 800 lmOperating time: 1h
Eleva - 2016 - V. 2Pag. 56
Halley
Commercial SportsIndustrial