Quidway S9300 Terabit Routing Switch
V100R003C00
Quick Start - SPU
Issue 02
Date 2010-07-15
HUAWEI TECHNOLOGIES CO., LTD.
-
8/6/2019 Quick Start - SPU(V100R003C00_02)[1]
2/46
Copyright Huawei Technologies Co., Ltd. 2010. All rights reserved.
No part of this document may be reproduced or transmitted in any form or by any means without prior written
consent of Huawei Technologies Co., Ltd.
Trademarks and Permissions
and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.
All other trademarks and trade names mentioned in this document are the property of their respective holders.
Notice
The purchased products, services and features are stipulated by the contract made between Huawei and the
customer. All or part of the products, services and features described in this document may not be within the
purchase scope or the usage scope. Unless otherwise specified in the contract, all statements, information,and recommendations in this document are provided "AS IS" without warranties, guarantees or representations
of any kind, either express or implied.
The information in this document is subject to change without notice. Every effort has been made in the
preparation of this document to ensure accuracy of the contents, but all statements, information, and
recommendations in this document do not constitute the warranty of any kind, express or implied.
Huawei Technologies Co., Ltd.
Address: Huawei Industrial Base
Bantian, Longgang
Shenzhen 518129
People's Republic of China
Website: http://www.huawei.com
Email: [email protected]
Issue 02 (2010-07-15) Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
i
http://www.huawei.com/ -
8/6/2019 Quick Start - SPU(V100R003C00_02)[1]
3/46
About This Document
Intended Audience
This document is intended for:
l Hardware installation engineers
l Commissioning engineers
l On-site maintenance engineers
l System maintenance engineers
Symbol Conventions
The symbols that may be found in this document are defined as follows.
Symbol Description
DANGER
Indicates a hazard with a high level of risk, which if not
avoided, will result in death or serious injury.
WARNING
Indicates a hazard with a medium or low level of risk, which
if not avoided, could result in minor or moderate injury.
CAUTION
Indicates a potentially hazardous situation, which if not
avoided, could result in equipment damage, data loss,
performance degradation, or unexpected results.
TIP Indicates a tip that may help you solve a problem or save
time.
NOTE Provides additional information to emphasize or supplement
important points of the main text.
Change History
Updates between document issues are cumulative. Therefore, the latest document issue containsall updates made in previous issues.
Quidway S9300 Terabit Routing Switch
Quick Start - SPU About This Document
Issue 02 (2010-07-15) Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
iii
-
8/6/2019 Quick Start - SPU(V100R003C00_02)[1]
4/46
Changes in Issue 02 (2010-07-15)
Based on issue 01 (2010-04-30), the document is updated as follows:
The following information is modified:
1 Overview of the SPU.
Changes in Issue 01 (2010-04-30)
Initial commercial release.
About This Document
Quidway S9300 Terabit Routing Switch
Quick Start - SPU
iv Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
Issue 02 (2010-07-15)
-
8/6/2019 Quick Start - SPU(V100R003C00_02)[1]
5/46
Contents
About This Document...................................................................................................................iii
1 Overview of the SPU.................................................................................................................1-1
1.1 Introduction to the SPU...................................................................................................................................1-2
1.2 Functions and Typical Applications of the SPU.............................................................................................1-2
2 Hardware Structure of the SPU...............................................................................................2-1
2.1 Panel................................................................................................................................................................2-2
2.2 Description of Interfaces on the SPU..............................................................................................................2-3
2.3 Attributes of Interfaces on the SPU.................................................................................................................2-3
2.4 Technical Specifications.................................................................................................................................2-4
3 LoggingIn to the SPU...............................................................................................................3-1
3.1 Logging In to the SPU Through the Console Interface...................................................................................3-2
3.2 Logging In to the SPU Through the Console Interface of the SPU That Is Redirected from MPU...............3-5
3.3 Logging In to the SPU Through Telnet...........................................................................................................3-6
4 Service Features of the SPU......................................................................................................4-1
5 Replacing an SPU.......................................................................................................................5-1
6 Technical Specifications of the SPU.......................................................................................6-1
6.1 System Configurations of the SPU..................................................................................................................6-2
6.2 Technical Specifications of the SPU...............................................................................................................6-2
Quidway S9300 Terabit Routing Switch
Quick Start - SPU Contents
Issue 02 (2010-07-15) Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
v
-
8/6/2019 Quick Start - SPU(V100R003C00_02)[1]
6/46
Figures
Figure 1-1 Processing packets by the SPU...........................................................................................................1-2
Figure 1-2 Networking of server load balancing..................................................................................................1-3
Figure 1-3 Networking of egress link load balancing..........................................................................................1-4
Figure 1-4 Networking of IPSec..........................................................................................................................1-4
Figure 1-5 Networking of NAT............................................................................................................................1-5
Figure 1-6 Networking of the virtual firewall......................................................................................................1-6
Figure 1-7 Networking of the firewall in transparent mode.................................................................................1-7
Figure 1-8 Networking of firewalls in backup mode...........................................................................................1-8
Figure 1-9 Monitoring MPLS network traffic......................................................................................................1-9
Figure 1-10Monitoring traffic carried by a tunnel............................................................................................1-10
Figure 2-1 VAMPA panel....................................................................................................................................2-2
Figure 3-1 Logging in to the SPU through the console interface.........................................................................3-2
Figure 3-2 Setting up a new connection...............................................................................................................3-3
Figure 3-3 Configuring the connected interface...................................................................................................3-3Figure 3-4 Setting communication parameters.....................................................................................................3-4
Figure 3-5 Selecting a terminal type....................................................................................................................3-5
Figure 3-6 Networking of redirecting to the console interface of the SPU through the MPU of the S9300.......3-6
Figure 3-7 Logging in to the SPU through Telnet on the PC...............................................................................3-7
Figure 5-1 Schematic diagram of removing an SPU............................................................................................5-2
Figure 5-2 Schematic diagram of installing an SPU............................................................................................5-3
Quidway S9300 Terabit Routing Switch
Quick Start - SPU Figures
Issue 02 (2010-07-15) Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
vii
-
8/6/2019 Quick Start - SPU(V100R003C00_02)[1]
7/46
Tables
Table 2-1 Buttons and indicators on the VAMPA panel......................................................................................2-2
Table 2-2 Interfaces on the VAMPA and their functions.....................................................................................2-3
Table 2-3 Serial interface attributes......................................................................................................................2-3
Table 2-4 Ethernet interface attributes................................................................................................................. 2-3
Table 2-5 Technical specifications of the VAMPA............................................................................................. 2-4
Table 3-1 Communication parameters................................................................................................................. 3-4
Table 6-1 System configurations of the SPU....................................................................................................... 6-2
Table 6-2 Software service features and hardware technical specifications of the SPU......................................6-2
Quidway S9300 Terabit Routing Switch
Quick Start - SPU Tables
Issue 02 (2010-07-15) Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
ix
-
8/6/2019 Quick Start - SPU(V100R003C00_02)[1]
8/46
1Overview of the SPUAbout This Chapter
Functioning as the value-added service (VAS) board of the S9300, the Service Process Unit
(SPU) provides service functions such as load balancing, firewalls, Network Address Translation
(NAT), IP Security (IPSec), and NetStream, thus meeting requirements of different application
scenarios for diverse industry networks.
NOTE
The release of Russia does not provide the IPSec VPN function.
1.1 Introduction to the SPU
The SPU provides service functions such as load balancing, firewalls, NAT, IPSec, NetStreamin diverse network application scenarios. These functions are mainly used on industry networks.
1.2 Functions and Typical Applications of the SPU
The SPU canbe installed in any LPU slot of the S9300 to process the packets that are transmitted
from the MPU of the S9300. The SPU is applicable to load balancing, NAT, firewall, IPSec,
and NetSream solutions.
Quidway S9300 Terabit Routing Switch
Quick Start - SPU 1 Overview of the SPU
Issue 02 (2010-07-15) Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
1-1
-
8/6/2019 Quick Start - SPU(V100R003C00_02)[1]
9/46
1.1 Introduction to the SPUThe SPU provides service functions such as load balancing, firewalls, NAT, IPSec, NetStream
in diverse network application scenarios. These functions are mainly used on industry networks.
In modern enterprises, video conferences and video monitoring devices are widely used; shared
files such as pictures and high-definition video files are transmitted on intranets; servers and
storage devices need to back up data periodically. With the preceding requirements of
enterprises, people raise higher requirements for the reliability, security, and simplified operation
and management of industry networks.
As the VAS unit of the S9300, the SPU provides diverse VAS functions for industry networks,
such as load balancing, IPSec VPN, NAT, firewalls, and two-node cluster backup. In addition,
the SPU provides solutions to the network security of communities, interconnection between
communities, and wireless local area networks (WLANs). The SPU provides the high-efficient
load balancing solution, which accelerates the response speed of the IT system, shortens the
application delay, and balances the traffic on network devices. In this manner, the service
reliability can be improved and services can be expanded flexibly. Multiple firewalls and the
IPSec VPN facilitates integration of the VLAN switching technology of switches with security
network technologies, thus providing security services and implementing the secure and
encrypted interaction among departments of customers. NetStream provides data support for
charging and settlement, network planning, and network operation and management for most
carriers.
1.2 Functions and Typical Applications of the SPUThe SPU can be installed in any LPU slot of the S9300 to process the packets that are transmitted
from the MPU of the S9300. The SPU is applicable to load balancing, NAT, firewall, IPSec,
and NetSream solutions.
Currently, the SPU supports only one board, namely, VAMPA, which is installed in the LPU
slot of the S9300. The system transmits the packets to be processed to the SPU. Then the SPU
processes the packets related to the VASs. Figure 1-1 shows the processing procedure.
Figure 1-1 Processing packets by the SPU
Receiving
Packets
Switching Packets
Processing Packets SPU
MPU
LPUTransmitting
Packets
1 Overview of the SPU
Quidway S9300 Terabit Routing Switch
Quick Start - SPU
1-2 Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
Issue 02 (2010-07-15)
-
8/6/2019 Quick Start - SPU(V100R003C00_02)[1]
10/46
The VAMPA provides the following functions:
l Service functions
IPSec VPN, firewall/NAT, load balancing, and NetStream
Data processing capability of 10 Gbit/s
Routing and addressing for packets
Traffic management, congestion control, and forwarding scheduling for packets
Line-speed forwarding of packets
l Debugging functions
Configuration and alarm
Board environment monitoring
Watchdog
Hierarchical reset
Commissioning
The SPU is applicable to the following solutions.
Load Balancing
l Server load balancing
Figure 1-2 Networking of server load balancing
ServerA
ServerB
ServerC
SwitchIntranet
User
Intranet
External
Network
As shown in Figure 1-2, an Intranet user accesses the internal server that is deployed in
the group of load balancing servers through the external network. The group is composed
of three servers. As the load balancing (LB) device, the Switch implements load balancing
at layers from L4 to L7. The service load varies according to servers. When one or more
servers are faulty, the system automatically switches services to normal servers so that
services are not interrupted. In this manner, network faults are reduced and the reliability
of service processing is improved.
l Egress link load balancing
Quidway S9300 Terabit Routing Switch
Quick Start - SPU 1 Overview of the SPU
Issue 02 (2010-07-15) Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
1-3
-
8/6/2019 Quick Start - SPU(V100R003C00_02)[1]
11/46
Figure 1-3 Networking of egress link load balancing
ISP2
ISP1
Intranet
userSwitch
RouterA
RouterB
ExternalNetwork
As shown in Figure 1-3, an enterprise rents links of multiple carriers as egresses between
the Intranet and the external network. The bandwidth and delay vary according to carriers.
You can configure the Switch (SPU) to select the optimal link according to requirements
for external network access of different enterprise users. The Switch also supports the
reverse NAT function.
IPSec
Figure 1-4 Networking of IPSec
Internet
SwitchA SwitchB
IntranetUser A
IntranetUser B
As shown in Figure 1-4, an IPSec tunnel is set up between Switch A and Switch B. In this way,
data flows of intranet user A and intranet user B can be protected when being transmitted on
insecure networks. IPSec allows network users or administrators to control the granularity of
security services between peers. The Security Association (SA) can be established manually or
in IKE negotiation mode. The SA provides security protection for different data flows.
1 Overview of the SPU
Quidway S9300 Terabit Routing Switch
Quick Start - SPU
1-4 Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
Issue 02 (2010-07-15)
-
8/6/2019 Quick Start - SPU(V100R003C00_02)[1]
12/46
NAT
Figure 1-5 Networking of NAT
PC1
WWW FTP SMTP
Internet
PC2
10.1.1.1/24
10.1.2.1/24
Intranet
As shown in Figure 1-5, IP addresses of PC1 and PC2 on the intranet can be mapped to thepublic IP addresses on the external network through NAT. In this way, users on private networks
can access external networks, thus saving public IP addresses. The NAT mapping table is used
to limit hosts on internal networks that access hosts on external networks.
By configuring the internal servers, you can map the corresponding external IP addresses and
port numbers to internal servers. In this manner, users on external networks can access internal
servers. For example, an enterprise provides World Wide Web (WWW), File Transfer Protocol
(FTP), and Simple Mail Transfer Protocol (SMTP) services externally.
Firewall
l Virtual firewall
Quidway S9300 Terabit Routing Switch
Quick Start - SPU 1 Overview of the SPU
Issue 02 (2010-07-15) Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
1-5
-
8/6/2019 Quick Start - SPU(V100R003C00_02)[1]
13/46
Figure 1-6 Networking of the virtual firewall
Interior
SubnetworkInterior
Subnetwork
Interior
Subnetwork
Internet
VLAN2 VLAN3 VLAN4
FTP
Server
WWW
Server
Telnet
Server
Switch
As shown in Figure 1-6, an intranet can be divided into multiple subnets through VLANs.
The Switch (SPU) configures a virtual firewall for each subnet. The server on each subnet
can access external networks through the Switch and provide different services externally.
l Firewall in transparent mode
1 Overview of the SPU
Quidway S9300 Terabit Routing Switch
Quick Start - SPU
1-6 Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
Issue 02 (2010-07-15)
-
8/6/2019 Quick Start - SPU(V100R003C00_02)[1]
14/46
Figure 1-7 Networking of the firewall in transparent mode
Zone A
PC A
Zone B
PC B
Zone C
PC C
Switch
VLAN 10
VLAN 20
VLAN 30
As shown in Figure 1-7, the Switch functions as the firewall in transparent mode. In this
case, all interfaces are L2 interfaces and the network is divided into multiple access zonesthrough different VLANs. All PCs in a zone share the same network segment. The packet
filtering, attack defense, and traffic monitoring policies are defined for different VLANs
on the Switch. For example, PC A can access Zone B and Zone C. PC B can send packets,
whereas the packets cannot pass the firewall.
l Firewalls in backup mode
Quidway S9300 Terabit Routing Switch
Quick Start - SPU 1 Overview of the SPU
Issue 02 (2010-07-15) Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
1-7
-
8/6/2019 Quick Start - SPU(V100R003C00_02)[1]
15/46
Figure 1-8 Networking of firewalls in backup mode
PC 1
Switch
PC 2
Internet
SPU1
SPU2
As shown in Figure 1-8, SPU 1 and SPU 2 are installed on the Switch. VRRP is enabled
on these two SPUs to provide a virtual IP address for the switch and thus to back up services.
When SPU 1 functions as the master, data flows are transmitted to the Internet through
SPU 1. At the same time, data is synchronized from SPU 1 to SPU 2. After SPU 1 becomes
faulty, data flows are transmitted to the Internet through SPU 2.
NetStreaml Monitoring MPLS network traffic
1 Overview of the SPU
Quidway S9300 Terabit Routing Switch
Quick Start - SPU
1-8 Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
Issue 02 (2010-07-15)
-
8/6/2019 Quick Start - SPU(V100R003C00_02)[1]
16/46
Figure 1-9 Monitoring MPLS network traffic
PC
PE
PEPE
P
PE
PEPE
NSC&NDA
Web Server
Mail Server
FTP Server
AS 100
AS 200
PC PC
As shown in Figure 1-9, users can collect statistics on IP traffic from MPLS to IP (IPv4
or IPv6) and from IP (IPv4 or IPv6) to MPLS by deploying NetStream on user-side
interfaces of PEs. Users can also collect statistics on MPLS packets by deploying NetStream
on network-side interfaces of PEs and P devices. According to the analysis result of the
statistics, users can understand the composition and mode of the MPLS service accurately.l Monitoring traffic carried by a tunnel
Quidway S9300 Terabit Routing Switch
Quick Start - SPU 1 Overview of the SPU
Issue 02 (2010-07-15) Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
1-9
-
8/6/2019 Quick Start - SPU(V100R003C00_02)[1]
17/46
Figure 1-10 Monitoring traffic carried by a tunnel
PC
NSC&NDA
Web Server
Mail Server
FTP Server
AS 100
PC PC
Tunnel
AS 100
As shown in Figure 1-10, if a user collects statistics on the traffic transmitted through a
tunnel on physical interfaces of the switch, the user cannot differentiate the traffic carried
by the tunnel. In this case, the user needs to collect traffic statistics by using NetStream
twice, that is, before the traffic enters the tunnel and after the traffic exits the tunnel. In thisway, the user can accurately analyze the traffic composition in the tunnel.
1 Overview of the SPU
Quidway S9300 Terabit Routing Switch
Quick Start - SPU
1-10 Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
Issue 02 (2010-07-15)
-
8/6/2019 Quick Start - SPU(V100R003C00_02)[1]
18/46
2Hardware Structure of the SPUAbout This Chapter
This topic describes hardware information about the VAMPA. Currently, the SPU supports only
the VAMPA.
2.1 Panel
This topic describes the appearance of the SPU, including interfaces, indicators and the colors
and blinking states of interface and board indicators.
2.2 Description of Interfaces on the SPU
This topic describes types, quantity, and functions of interfaces on the SPU.
2.3 Attributes of Interfaces on the SPU
This topic describes connector types, attributes, operation modes, and compliance standards of
the interfaces on the panel.
2.4 Technical Specifications
This topic describes technical specifications of the SPU, such as board dimensions, panel
dimensions, maximum power consumption, and weight.
Quidway S9300 Terabit Routing Switch
Quick Start - SPU 2 Hardware Structure of the SPU
Issue 02 (2010-07-15) Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
2-1
-
8/6/2019 Quick Start - SPU(V100R003C00_02)[1]
19/46
2.1 Panel
This topic describes the appearance of the SPU, including interfaces, indicators and the colors
and blinking states of interface and board indicators.
Currently, the SPU supports only the VAMPA.
The VAMPA is installed horizontally. A serial interface (identified as CON) and an FE electrical
interface (identified as ETH) are located on the panel. Figure 2-1 shows the panel.
Figure 2-1 VAMPA panel
1. ACT indicator 2. LINK indicator
The board indicator RUN/ALM and interface indicators ACT and LINK are located on the
VAMPA panel. Table 2-1 describes the colors and blinking states of the indicators.
Table 2-1 Buttons and indicators on the VAMPA panel
Indicator/Button Color Description
RUN/ALM Green If the indicator is on, it indicates that the board is
powered on but the software is not running.
If the indicator blinks slowly (0.5 Hz), it indicates
that the system runs normally.
If the indicator blinks quickly (4 Hz), it indicates that
the system is being started.
Red If the indicator is on, it indicates that the board is
faulty.
Orange If the indicator is on, it indicates that the board is
installed in the slot and is powered on.
ACT Amber If the indicator blinks, it indicates that data is being
transmitted or received.
If the indicator is off, it indicates that no data is being
transmitted or received.
LINK Green-yellow If the indicator is on, it indicates that the link is
connected.
If the indicator is off, it indicates that the link is
blocked.
2 Hardware Structure of the SPU
Quidway S9300 Terabit Routing Switch
Quick Start - SPU
2-2 Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
Issue 02 (2010-07-15)
-
8/6/2019 Quick Start - SPU(V100R003C00_02)[1]
20/46
2.2 Description of Interfaces on the SPU
This topic describes types, quantity, and functions of interfaces on the SPU.
Table 2-2 describes types and functions of interfaces on the VAMPA.
Table 2-2 Interfaces on the VAMPA and their functions
Interface Quantity Description
Console interface 1 Provides a serial interface. A user can log in to the local
SPU by connecting the serial interface on the host and
the console interface on the SPU through a cable to
configure the SPU locally.
Ethernet interface 1 Provides an FE electrical interface. A user can log in to
the SPU through Telnet to configure the SPU.
2.3 Attributes of Interfaces on the SPU
This topic describes connector types, attributes, operation modes, and compliance standards of
the interfaces on the panel.
Table 2-3 and Table 2-4 describe attributes of the interfaces on the panel.
Table 2-3 Serial interface attributes
Attribute Description
Connector type RJ45
Interface attribute RS232
Compliance standard EIA/TIA-232
Table 2-4 Ethernet interface attributes
Attribute Description
Connector type RJ45
Interface attribute 10BASE-T/100BASE-TX
Operation mode Full duplex
Compliance standard IEEE 802.3
Quidway S9300 Terabit Routing Switch
Quick Start - SPU 2 Hardware Structure of the SPU
Issue 02 (2010-07-15) Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
2-3
-
8/6/2019 Quick Start - SPU(V100R003C00_02)[1]
21/46
2.4 Technical Specifications
This topic describes technical specifications of the SPU, such as board dimensions, panel
dimensions, maximum power consumption, and weight.
Table 2-5 describes technical specifications of the VAMPA.
Table 2-5 Technical specifications of the VAMPA
Parameter Description
Board dimensions 426.80 mm x 394.70 mm x 35.10 mm (width
x depth x height)
Maximum power consumption 153.27 w
Board weight 2.6 kg
2 Hardware Structure of the SPU
Quidway S9300 Terabit Routing Switch
Quick Start - SPU
2-4 Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
Issue 02 (2010-07-15)
-
8/6/2019 Quick Start - SPU(V100R003C00_02)[1]
22/46
3 Logging In to the SPUAbout This Chapter
A user can log in to the SPU in either of the following ways: logging in to the SPU through the
console interface; logging in to the SPU through Telnet; logging in to the MPU of the S9300 for
redirection, and then logging in to the SPU through the console interface of the SPU.
3.1 Logging In to the SPU Through the Console Interface
If a user cannot log in to the MPU of the S9300, the user needs to log in to the SPU through the
console interface for the first time. This topic describes how to log in to the SPU on a PC through
the console interface.
3.2 Logging In to the SPU Through the Console Interface of the SPU That Is Redirected from
MPU
If a user has logged in to the MPU of the S9300, the user can log in to the SPU after redirection
to the console interface of the SPU.
3.3 Logging In to the SPU Through Telnet
This topic describes how to log in to the SPU through Telnet.
Quidway S9300 Terabit Routing Switch
Quick Start - SPU 3 Logging In to the SPU
Issue 02 (2010-07-15) Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
3-1
-
8/6/2019 Quick Start - SPU(V100R003C00_02)[1]
23/46
3.1 Logging In to the SPU Through the Console Interface
If a user cannot log in to the MPU of the S9300, the user needs to log in to the SPU through the
console interface for the first time. This topic describes how to log in to the SPU on a PC through
the console interface.
Networking Requirements
When logging in to the SPU through the console interface, a user needs to connect the console
interface on the SPU to the RS232 interface on the host through a serial cable, as shown in
Figure 3-1.
Figure 3-1 Logging in to the SPU through the console interface
Console Cable
RS232
interface
Console
interface
Procedure
Step 1 Connect the PC with the SPU through a serial cable according to Figure 3-1.
Step 2 Enable the HyperTerminal on the PC.
Choose Start > All Programs > Accessories > Communications > HyperTerminal to start
the HyperTerminal.
Step 3 Set up a new connection.
As shown in Figure 3-2, enter the name of the new connection in the Name text box and choose
an icon. ClickOK.
3 Logging In to the SPU
Quidway S9300 Terabit Routing Switch
Quick Start - SPU
3-2 Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
Issue 02 (2010-07-15)
-
8/6/2019 Quick Start - SPU(V100R003C00_02)[1]
24/46
Figure 3-2 Setting up a new connection
Step 4 Configure the connected interface.
In the Connect window shown in Figure 3-3, select an interface from the Connect drop-down
list box according to the interface on the PC or terminal. Then clickOK.
Figure 3-3 Configuring the connected interface
Step 5 Set communication parameters.
In the COM1 Properties window shown in Figure 3-4, set communication parametersaccording to Table 3-1.
Quidway S9300 Terabit Routing Switch
Quick Start - SPU 3 Logging In to the SPU
Issue 02 (2010-07-15) Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
3-3
-
8/6/2019 Quick Start - SPU(V100R003C00_02)[1]
25/46
NOTE
In the Windows operating systems of some versions, Bit per second may be called Baud rate and Flow
control may be called Traffic control.
Figure 3-4 Setting communication parameters
Table 3-1 Communication parameters
Parameter Value
Bit per second (baud) 9600
Data bit 8
Parity check None
Stop bit 1
Flow control (traffic control) None
Step 6 After starting the HyperTerminal, choose File > Attributes to display the COMM1Properties dialog box, as shown in Figure 3-5. Click the Settings tab, and select Auto detect
orVT100 from the Emulation drop-down list box. ClickOKto complete the settings.
3 Logging In to the SPU
Quidway S9300 Terabit Routing Switch
Quick Start - SPU
3-4 Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
Issue 02 (2010-07-15)
-
8/6/2019 Quick Start - SPU(V100R003C00_02)[1]
26/46
Figure 3-5 Selecting a terminal type
After the preceding settings, press Enter. If the prompt is displayed, it indicates
that you have logged in to the SPU. In this case, you can enter commands to configure or manage
the SPU.
----End
3.2 Logging In to the SPU Through the Console Interface ofthe SPU That Is Redirected from MPU
If a user has logged in to the MPU of the S9300, the user can log in to the SPU after redirection
to the console interface of the SPU.
Networking Requirements
A user can log in to the MPU of the S9300 through a serial interface or through Telnet, and then
run the corresponding command for redirection. Then the user redirects the login process to the
console interface of the SPU as prompted and logs in to the SPU through the console interface,
as shown in Figure 3-6.
Quidway S9300 Terabit Routing Switch
Quick Start - SPU 3 Logging In to the SPU
Issue 02 (2010-07-15) Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
3-5
-
8/6/2019 Quick Start - SPU(V100R003C00_02)[1]
27/46
Figure 3-6 Networking of redirecting to the console interface of the SPU through the MPU of
the S9300
Console
interface of
the SPU
Login Redirection
PC S9300
Procedure
Step 1 Log in to the MPU of the S9300.
Step 2 Run the following command in the user view: spu connectslotslot-num.
slot-num indicates the number of the slot where the SPU is installed on the S9300.
The following message is displayed:
******************************************************
* Slot 2 output to mainboard *
******************************************************
Press Ctrl+D to quit
Step 3 Press Enter. The system displays the following information:The console can not be used now, pleae press Ctrl+Y.
Press Ctrl+Y. The system redirects you to the serial interface of the SPU so that you can log in
to the SPU.
NOTE
To return to the MPU of the S9300, press Ctrl+D.
The serial interface of the SPU can be used as:
l Ingress for redirecting to the SPU from the MPU of the S9300
l Ingress for logging in to the SPU
You can press Ctrl+Y to switch the roles of the serial interface on the SPU. The serial interface can be
function as either the ingress for redirecting to the SPU from the MPU of the S9300 or the ingress for
logging in to the SPU .
----End
3.3 Logging In to the SPU Through Telnet
This topic describes how to log in to the SPU through Telnet.
Networking Requirements
Telnet supports local and remote login, facilitating maintenance. After setting the Telnet user
of the SPU, a user can log in to the SPU through Telnet from the Ethernet interface or service
interfaces such as XGE sub-interface or the Eth-Trunk sub-interface whose member interfacesare XGE interfaces, as shown in Figure 3-7.
3 Logging In to the SPU
Quidway S9300 Terabit Routing Switch
Quick Start - SPU
3-6 Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
Issue 02 (2010-07-15)
-
8/6/2019 Quick Start - SPU(V100R003C00_02)[1]
28/46
Figure 3-7 Logging in to the SPU through Telnet on the PC
STCCrossover
cable
Crossovercable or
optical fiber
HUB
L2 Switch
PC
PC
PC
SPU
SPU
SPU
STC
STC
NOTE
The SPU is a board installed on the S9300. Generally, the ETH port of the SPU is not used to connect to
the network; therefore, the service interface of the SPU is usually used for logging in to the SPU through
Telnet.
In this way, you can configure the user name and password of the Telnet user on the SPU. The
method for configuring a Telnet user on the SPU is the same as that for configuring a Telnet
user on the S9300. For details, see the Quidway S9300 Terabit Routing Switch ConfigurationGuide - Basic Configuration.
If you do not configure the Telnet user on the SPU, the user name and password are absent for
the first login through Telnet.
Procedure
Step 1 Set the IP address of the Ethernet interface of the SPU.
You can log in to the SPU by using the following methods:
l Using the console port of the SPU
l Redirecting to the SPU from the S9300
After logging in to the SPU, do as follows:
l Assign an IP address to the ETH port.
1. Run the system-view command to enter the system view.
2. Run the interfaceinterface-type interface-numbercommand to enter the interface view.
Here, Ethernet 0/0/0 is used.
3. Run the ip addressip-address { mask| mask-length } command to set the IP address
of the interface.
l Assign an IP address to the service interface.
Quidway S9300 Terabit Routing Switch
Quick Start - SPU 3 Logging In to the SPU
Issue 02 (2010-07-15) Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
3-7
-
8/6/2019 Quick Start - SPU(V100R003C00_02)[1]
29/46
The service interface of the SPU is the Eth-Trunk sub-interface whose member interfaces
are XGE interfaces or the XGE sub-interface. The configuration methods of the Eth-Trunk
interface and the XGE sub-interface are different. The details are as follows:
Assign an IP address to the XGE sub-interface.
1. Run the system-view command to enter the system view.
2. Run the interfacexgigabitethernetinterface-number.subinterface-number
command to enter the XGE sub-interface view.
3. Run the ip addressip-address { mask| mask-length } [ sub ] command to assign an
IP address to the XGE sub-interface.
Assign an IP address to the Eth-Trunk sub-interface whose member interfaces are XGE
interfaces.
1. Run the system-view command to enter the system view.
2. Run the interface eth-trunktrunk-idcommand to enter the Eth-Trunk interface
view.
3. Run the trunkportxgigabitethernet { interface-number1 [ tointerface-number2 ] } & command to add two virtual interfaces of the SPU to the Eth-
Trunk interface to complete link aggregation.
4. Run the quit command to exit the Eth-Trunk interface view.
5. Run the interface eth-trunktrunk-id.subtrunk-idcommand to enter the Eth-Trunk
sub-interface view.
6. Run the ip addressip-address { mask| mask-length } [ sub ] command to assign an
IP address to the Eth-Trunk sub-interface.
Step 2 Log in to the SPU through Telnet.
A user can log in to the SPU on the local PC or terminal through Telnet.
1. Open the Command Prompt window on the PC.
Choose Start > Programs > Accessories > Command Prompt. The Command
Prompt window is displayed.
The Command Prompt window displays the following messages:
Microsoft Windows XP [version 5.1.2600]
(c) Versions 1985-2001 Microsoft Corp.
C:\>
2. Access the Telnet client.
At the prompt C:\>, enterTelnet. The Command Prompt window displays the following
messages:
Microsoft Windows XP [Versions 5.1.2600]
(c) Version 1985-2001 Microsoft Corp.
C:\> telnet
Press Enter to access the Telnet client. The Command Prompt window displays the
following messages:
Welcome to use Microsoft Telnet Client
Escape character is CTRL+]
Microsoft Telnet>
3. Connect the Telnet server.
At the prompt Microsoft Telnet>, enter the following command to connect to the Telnetserver. The format is as follows:
3 Logging In to the SPU
Quidway S9300 Terabit Routing Switch
Quick Start - SPU
3-8 Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
Issue 02 (2010-07-15)
-
8/6/2019 Quick Start - SPU(V100R003C00_02)[1]
30/46
open { ip-address | host-name } [port]
ip-address: specifies the IP address of a Telnet server.
host-name: specifies the host name of a Telnet server.
port: specifies the number of the interface for the Telnet service on a Telnet server. The
default value is 23.
Exampe:
# Connect to the SPU whose IP address is 1.1.1.1. The default port number is 23.
Welcome to use Microsoft Telnet Client
Escape character is '[CTRL+]'
Microsoft Telnet> open 1.1.1.1
Trying 1.1.1.1 ...
Press CTRL+K to abort
Connected to 1.1.1.1 ...
Info: The max number of VTY users is 20, and the number
of current VTY users on line is 1.
----End
Quidway S9300 Terabit Routing Switch
Quick Start - SPU 3 Logging In to the SPU
Issue 02 (2010-07-15) Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
3-9
-
8/6/2019 Quick Start - SPU(V100R003C00_02)[1]
31/46
4 Service Features of the SPUThis topic describes all the features supported by the SPU according to the feature description
in each volume (basic configuration, Ethernet, IP service, IP routing, QoS, security, reliability,
device management, network management, and VPN).
Basic Configuration
Feature Description Supported bythe SPUOnly
Remarks
File
system
A file system manages
files and directories in the
storage device. In the file
system, you can create,
delete, modify, and
rename a file or a
directory, and display
contents of a file.
No The feature of the SPU is the same as that
of the S9300. For details, see
Management of Configuration Files in the
Quidway S9300 Terabit Routing Switch
Configuration Guide - Basic
Configuration.
Login
throug
h the
Console
interfac
e
In the case that the
network is unreachable, a
user needs to log in to the
SPU through the console
interface.
No The feature of the SPU is the same as that
of the S9300. To log in to the SPU through
the console interface, see 3.1 Logging In
to the SPU Through the Console
Interface.
Login
throug
h Telnet
In the case that the
network is reachable, a
user can log in to the SPU
on the local PC or
through Telnet.
No The feature of the SPU is the same as that
of the S9300 in some aspects. The
difference is as follows: A user can
configure the IP address of the Ethernet
interface on the SPU by logging in to the
MPU of the S9300. To log in to the SPU
through Telnet, see 3.3 Logging In to the
SPU Through Telnet.
Quidway S9300 Terabit Routing Switch
Quick Start - SPU 4 Service Features of the SPU
Issue 02 (2010-07-15) Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
4-1
-
8/6/2019 Quick Start - SPU(V100R003C00_02)[1]
32/46
Feature Description Supported bythe SPUOnly
Remarks
SSH
login
The SSH supports secure
local and remote login.
The SPU supports the
route iteration by the
BGP.
No The feature of the SPU is the same as that
of the S9300. For details, see
Configuration of the SSH Server and
Client in the Quidway S9300 Terabit
Routing Switch Configuration Guide -
Basic Configuration.
Ethernet
Feature Description Supported bythe SPUOnly
Remarks
MAC A MAC address table
stores the MAC
addresses of other
devices learned by the
S9300, VLAN IDs, and
outbound interfaces that
are used to send data.
Before forwarding thedata, the SPU searches
the MAC address table
based on the destination
MAC address and the
VLAN ID of the data to
find the corresponding
outgoing interface
rapidly. This reduces the
number of broadcast
packets.
No The feature of the SPU is the same as that
of the S9300. For details, see MAC
Address Table Configuration in the
Quidway S9300 Terabit Routing Switch
Configuration Guide - Ethernet.
ARP The Address ResolutionProtocol (ARP) provides
a mapping between an IP
address and a MAC
address.
No The feature of the SPU is the same as thatof the S9300. For details, see ARP
Configuration in the Quidway S9300
Terabit Routing Switch Configuration
Guide - Ethernet.
4 Service Features of the SPU
Quidway S9300 Terabit Routing Switch
Quick Start - SPU
4-2 Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
Issue 02 (2010-07-15)
-
8/6/2019 Quick Start - SPU(V100R003C00_02)[1]
33/46
Feature Description Supported bythe SPUOnly
Remarks
Link
aggrega
tion
Link aggregation refers
to a method of binding a
group of physical
interfaces together as a
logical interface to
increase the bandwidth.
By setting up a link
aggregation group
between two devices,
you can obtain higher
bandwidth and
reliability.
No The feature of the SPU is the same as that
of the S9300. For details, see Link
Aggregation Configuration in the
Quidway S9300 Terabit Routing Switch
Configuration Guide - Ethernet.
IP Services
Feature Description Supported bythe SPUOnly
Remarks
IP
addresssetting
This feature provides IP
addresses of interfaces.
No The SPU supports setting IP addresses on
sub-interfaces and tunnel interfaces only.For the configuration method, see the
Quidway S9300 Terabit Routing Switch
Configuration Guide - IP Services.
IP Routing
Feature Description Supported bythe SPU
Only
Remarks
IPv4
unicast
static
routes,
RIP,
OSPF,
IS-IS,
and
BGP
This feature provides
IPv4 static and dynamic
routing protocols to
implement interworking
at Layer 3.
No The feature of the SPU is the same as that
of the S9300. For details, see the Quidway
S9300 Terabit Routing Switch
Configuration Guide - IP Routing.
Quidway S9300 Terabit Routing Switch
Quick Start - SPU 4 Service Features of the SPU
Issue 02 (2010-07-15) Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
4-3
-
8/6/2019 Quick Start - SPU(V100R003C00_02)[1]
34/46
Feature Description Supported bythe SPUOnly
Remarks
Routing
policies
and
policy-
based
routing
A routing policy is used
to change the path that the
traffic passes through.
Different from the
routing mechanism based
on the destination
addresses of IP packets,
the policy-based routing
is a mechanism based on
the customized routing
policies.
No The feature of the SPU is the same as that
of the S9300. For details, see the Quidway
S9300 Terabit Routing Switch
Configuration Guide - IP Routing.
Route
iteration
The route iteration is a
process of finding a
dependent route
according to the next hop
address. The SPU
supports route iteration
by the BGP.
No The feature of the SPU is the same as that
of the S9300. For details, see the Quidway
S9300 Terabit Routing Switch
Configuration Guide - IP Routing.
QoS
Feature Description Supported bythe SPUOnly
Remarks
Names
of the
traffic
classific
ation,
traffic
behavior, and
traffic
policy
During traffic
classification, packets
sharing common features
are classified into a class
by matching the
information carried in
packets with the specificrule. The packets of the
same class provide QoS
services for traffic of the
same type, and thus
provide differentiated
services for different
services.
No The feature of the SPU is the same as that
of the S9300. For details, see the Quidway
S9300 Terabit Routing Switch
Configuration Guide - QoS.
4 Service Features of the SPU
Quidway S9300 Terabit Routing Switch
Quick Start - SPU
4-4 Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
Issue 02 (2010-07-15)
-
8/6/2019 Quick Start - SPU(V100R003C00_02)[1]
35/46
Feature Description Supported bythe SPUOnly
Remarks
Priority
mappin
g
The packets are sent to
different interface queues
according to the internal
priority, and then traffic
shaping, congestion
avoidance, and queue
scheduling are performed
for the queues.
No The feature of the SPU is the same as that
of the S9300. For details, see the Quidway
S9300 Terabit Routing Switch
Configuration Guide - QoS.
Security
Feature Description Supported bythe SPUOnly
Remarks
ACL The ACL classifies
packets based on the
rules defined by the ACL.
After these rules are
applied to interfaces, the
device can determinewhich packets to accept
and which to deny.
No The feature of the SPU is the same as that
of the S9300. For details, see the Quidway
S9300 Terabit Routing Switch
Configuration Guide - Security.
IPSec By establishing the SA,
data can be encrypted and
data sources can be
authenticated at the IP
layer to ensure
confidentiality, data
integrity, data source
authentication, and anti-
replay for packets duringtransmission across the
network.
Yes -
Quidway S9300 Terabit Routing Switch
Quick Start - SPU 4 Service Features of the SPU
Issue 02 (2010-07-15) Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
4-5
-
8/6/2019 Quick Start - SPU(V100R003C00_02)[1]
36/46
Feature Description Supported bythe SPUOnly
Remarks
URPF URPF obtains the source
IP address and the
inbound interface of the
packet and checks
whether the inbound
interface corresponding
to the source IP address in
the forwarding table
matches the actual
inbound interface of the
packet. If they do not
match, URPF considersthe source IP address as a
pseudo address and
discards the packet. In
this way, URPF can
efficiently protect the
network against vicious
attacks initiated by
modifying the source
address.
No The feature of the SPU is the same as that
of the S9300. For details, see the Quidway
S9300 Terabit Routing Switch
Configuration Guide - Security.
NAT The NAT maps a few
public IP addresses tomore private IP
addresses. This can
temporarily solve the
problems resulted from
IP address shortage.
Yes -
Firewall The firewalls are
deployed to prevent
against most attacks from
external networks by
using packet filtering,
whitelists, blacklists, and
attack defense. In this
way, the security risks
confronted during
transmission across
networks can be avoided.
Yes -
4 Service Features of the SPU
Quidway S9300 Terabit Routing Switch
Quick Start - SPU
4-6 Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
Issue 02 (2010-07-15)
-
8/6/2019 Quick Start - SPU(V100R003C00_02)[1]
37/46
Reliability
Feature Description Supported bythe SPUOnly
Remarks
BFD The Bidirectional
Forwarding Detection
(BFD) is a detection
mechanism used
uniformly on an entire
network. It is used to
rapidly detect and
monitor the connectivity
of links or IP routes on a
network. A
communication failurebetween adjacent
systems must be detected
quickly and the standby
tunnel must be created
faster for communication
recovery.
No The feature of the SPU is the same as that
of the S9300. For details, see the Quidway
S9300 Terabit Routing Switch
Configuration Guide - Reliability.
VRRP By separating physical
devices from logical
devices, the Virtual
Router Redundancy
Protocol (VRRP)implements route
selection among multiple
egress gateways. In this
manner, services are not
affected when a gateway
is faulty, and the
configuration of the
routing protocol does not
need to be changed.
No The feature of the SPU is the same as that
of the S9300. For details, see the Quidway
S9300 Terabit Routing Switch
Configuration Guide - Reliability.
Load
balancing
The load balancing
function allocates trafficto multiple network
devices or links through
the specific load
balancing algorithm. In
this manner, the overall
network performance is
improved.
Yes -
Quidway S9300 Terabit Routing Switch
Quick Start - SPU 4 Service Features of the SPU
Issue 02 (2010-07-15) Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
4-7
-
8/6/2019 Quick Start - SPU(V100R003C00_02)[1]
38/46
Feature Description Supported bythe SPUOnly
Remarks
Two-
node
cluster
backup
An active device and a
standby device run
simultaneously to back
up the link data of the
other party. When a
device is faulty, data
flows can be switched to
another device smoothly.
This prevents service
interruption.
Yes -
Device Management
Feature Description Supported bythe SPUOnly
Remarks
Interfac
e
mirrorin
g
A packet passing through
a mirroring interface is
copied and then sent to a
specified observinginterface for analysis and
monitoring.
No The feature of the SPU is the same as that
of the S9300. For details, see the Quidway
S9300 Terabit Routing Switch
Configuration Guide - DeviceManagement.
Board
and
interfac
e
manage
ment
Manage registration,
initialization, and
initiation of boards.
Manage interface
attributes.
Yes -
4 Service Features of the SPU
Quidway S9300 Terabit Routing Switch
Quick Start - SPU
4-8 Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
Issue 02 (2010-07-15)
-
8/6/2019 Quick Start - SPU(V100R003C00_02)[1]
39/46
Network Management
Feature Description Supported bythe SPUOnly
Remarks
NetStre
am
NetStream is a
technology of collecting
and releasing statistics
about network traffic. It
classifies the statistics
about traffic flows and
resource usage on the
network. NetStream also
manages the network and
conducts charging based
on types of services andQoS.
No Another NetStream with other
specifications supported by the S9300 is
also supported by the SPU. For details, see
the Quidway S9300 Terabit Routing
Switch Configuration Guide - Network
Management.
Ping and
Tracert
The ping command is
used to check network
connectivity and whether
a host is reachable.
Tracert is used to check
IP addresses and the
number of gateways
between the source and
the destination. Tracert is
helpful in testing network
reachability and locating
the fault on the network.
No The feature of the SPU is the same as that
of the S9300. For details, see the Quidway
S9300 Terabit Routing Switch
Configuration Guide - Network
Management.
SNMP SNMP defines how
management information
is transmitted between
the network management
station and the agent
through the MIB.
No
The feature of the SPU is the same as that
of the S9300. For details, see the Quidway
S9300 Terabit Routing Switch
Configuration Guide - Network
Management.
Quidway S9300 Terabit Routing Switch
Quick Start - SPU 4 Service Features of the SPU
Issue 02 (2010-07-15) Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
4-9
-
8/6/2019 Quick Start - SPU(V100R003C00_02)[1]
40/46
VPN
Feature Description Supported bythe SPUOnly
Remarks
GRE GRE uses the tunnel
technololgy to
encapsulate packets of
some network protocols
such as IP and IPX. In
this manner, the
encapsulated packets can
be transmitted on
networks supporting
other protocols such as
IP.
No The feature of the SPU is the same as that
of the S9300. For details, see the Quidway
S9300 Terabit Routing Switch
Configuration Guide - VPN.
4 Service Features of the SPU
Quidway S9300 Terabit Routing Switch
Quick Start - SPU
4-10 Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
Issue 02 (2010-07-15)
-
8/6/2019 Quick Start - SPU(V100R003C00_02)[1]
41/46
5 Replacing an SPUThis topic describes precautions and procedure for replacing an SPU.
Precautions
Before replacing an SPU, pay attention to the following points:
Before replacing an SPU, prepare an SPU with the same specifications of the SPU to be replaced.
Tools
l ESD-preventive wrist straps or gloves
l ESD-preventive bag
Procedure
Step 1 Check the position of the SPU to be replaced.
Before removing the SPU that you need to replace, check the position of the the cabinet, chassis,
and slot where the SPU is installed.
l An S9312 has 12 LPU slots, which are numbered from 1 to 12.
l An S9306 has 6 LPU slots, which are numbered from 1 to 6.
l An S9303 has 3 LPU slots, which are numbered from 1 to 3.
Find out the SPU to be replaced in the chassis and attach a label to identify the SPU.
Step 2 Check whether there is any bent pin in the connector of the new SPU.
Step 3 Remove the cable from the SPU.
Step 4 Remove the SPU to be replaced from the chassis.
1. Wear ESD-preventive wrist straps and connect the grounding terminal to the ESD jack on
the chassis.
2. Hold the left and right ejector levers of the board with your hands. Press the springs of the
ejector levers to loosen the ejector levers. Turn the ejector levers of the SPU outwards.
When the ejector levers and the panel form a 45-degree angle, the SPU is removed fromthe backplane, as shown in (2) ofFigure 5-1.
Quidway S9300 Terabit Routing Switch
Quick Start - SPU 5 Replacing an SPU
Issue 02 (2010-07-15) Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
5-1
-
8/6/2019 Quick Start - SPU(V100R003C00_02)[1]
42/46
CAUTION
l During the operation, remove the SPU slowly and smoothly to prevent it from colliding
with other boards and causing failures of the running boards.l When swapping an SPU, do not touch the parts on the SPU to prevent it from being
damaged.
3. Hold the two ejector levers and pull out the SPU smoothly from the chassis along the guide
rail of the slot, as shown in (2) ofFigure 5-1.
4. Place the removed board in the ESD-preventative bag.
Figure 5-1 Schematic diagram of removing an SPU
Step 5 Install the new SPU into the chassis.
1. Take out the new SPU from the ESD-preventive bag.
CAUTION
l During the operation, install the SPU slowly and smoothly to prevent it from colliding
with other boards and causing failures of the running boards.
l When swapping an SPU, do not touch the parts on the SPU to prevent it from being
damaged.
2. Hold the two ejector levers and insert the SPU smoothly into the chassis along the guide
rail of the slot, as shown in (1) ofFigure 5-2. Push the SPU until the bayonets of the ejector
levers touch the edges of the chassis.
3. Secure the bayonets of the ejector levers on the edges of the chassis, and then push the
ejector levers inwards until you hear a click, as shown in (2) ofFigure 5-2.
5 Replacing an SPU
Quidway S9300 Terabit Routing Switch
Quick Start - SPU
5-2 Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
Issue 02 (2010-07-15)
-
8/6/2019 Quick Start - SPU(V100R003C00_02)[1]
43/46
Figure 5-2 Schematic diagram of installing an SPU
Step 6 Connect the cables to the corresponding interfaces in the original sequence.
Step 7 Check the running status of the new SPU.
In normal situations, after the new SPU is installed into the chassis, the SPU automatically
communicates with the MPU. In this case, check the running status of the new SPU as follows:
l If the RUN/ALM indicator on the panel of the SPU is green and blinks at the frequency of
0.5 Hz, it indicates that the SPU is running normally.
l You can check the alarms. In normal situations, the system does not generate any alarm
related to the new SPU.
l Run the display device command on the client after logging in to the SPU to view the running
status of the new SPU. If the output is displayed as follows, it indicates that the SPUs in the
corresponding slots are running normally.
display device
Step 8 Check service operations.
----End
Postrequisite
After finishing the replacement, put all the tools away. If an SPU that is replaced is confirmed
to be faulty, maintainers should fill in theFaulty Card for Repair, and mail the card and the
faulty SPU together to Huawei local office for timely maintenance.
Quidway S9300 Terabit Routing Switch
Quick Start - SPU 5 Replacing an SPU
Issue 02 (2010-07-15) Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
5-3
-
8/6/2019 Quick Start - SPU(V100R003C00_02)[1]
44/46
6 Technical Specifications of the SPUAbout This Chapter
This topic describes system parameters and technical specifications of the SPU.
6.1 System Configurations of the SPU
This topic describes the processor, DRAM, flash, CF card, and forwarding capability of the
SPU.
6.2 Technical Specifications of the SPU
This topic describes the software service features (Ethernet services, QoS, ACL, L3VPN, IP
unicast, and reliability services) and hardware (integrated system reliability) technical
specifications of the SPU.
Quidway S9300 Terabit Routing Switch
Quick Start - SPU 6 Technical Specifications of the SPU
Issue 02 (2010-07-15) Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
6-1
-
8/6/2019 Quick Start - SPU(V100R003C00_02)[1]
45/46
6.1 System Configurations of the SPU
This topic describes the processor, DRAM, flash, CF card, and forwarding capability of the
SPU.
Table 6-1 describes system configurations of the SPU.
Table 6-1 System configurations of the SPU
Description Example Remarks
Processor Two multi-kernal CPUs.
Each CPU is configured with
16 kernals. The dominant
frequency is 600 MHz.
Two CPUs
DDR2 DRAM 16 GB (8 bit, 2 x 4 GB). Each
CPU is connected to a
memory of 8 GB.
-
Flash 64 MB -
CF card 512 MB A CF card serves as a mass
storage device to save data
files and logs.
Forwarding capability 10 Gbit/s -
6.2 Technical Specifications of the SPU
This topic describes the software service features (Ethernet services, QoS, ACL, L3VPN, IP
unicast, and reliability services) and hardware (integrated system reliability) technical
specifications of the SPU.
Table 6-2 describes the software service features and hardware technical specifications of the
SPU.
Table 6-2 Software service features and hardware technical specifications of the SPU
Attribute Service Feature Technical Specification
Ethernet service
performance
Number of MAC addresses 128,000
Number of trunk groups and
maximum number of interfaces
supported by each trunk group
Two trunk groups, each of which
supports a maximum of two
interfaces
Rate of learning MAC addresses 3000 addresses/second
Number of ARPs 16,000
QoS performance CAR 8 kbit/s
6 Technical Specifications of the SPU
Quidway S9300 Terabit Routing Switch
Quick Start - SPU
6-2 Huawei Proprietary and Confidential
Copyright Huawei Technologies Co., Ltd.
Issue 02 (2010-07-15)
-
8/6/2019 Quick Start - SPU(V100R003C00_02)[1]
46/46
Attribute Service Feature Technical Specification
ACL ACLv4 Global: 32 thousand
VPN VRF 1000
VPN route 230,000
IP unicast Routing entries 230 thousand
IPv4 FIB 144 thousand
Reliability
service
BFD Number of static sessions of the
BFD: 32
Minimum fault discovery interval:
less than 100 ms
VRRP l VRRP groups: 255
l VRRP management groups: 16
l Virtual IP addresses in each
VRRP group: 16
l Minimum switchover interval:
3s if the BFD is not used; 100 ms
if BFD for VRRP is used.
Quidway S9300 Terabit Routing Switch
Quick Start - SPU 6 Technical Specifications of the SPU