Transcript
Page 1: ROCKWELL AUTOMATION, INC....CERTIFICATE NUMBER DATE 18-HS1781263-PDA 25 Sep 2018 ABS TECHNICAL OFFICE Houston ESD - Piping This is to certify that a representative of this Bureau did,

CERTIFICATE NUMBER DATE

18-HS1781263-PDA 25 Sep 2018

ABS TECHNICAL OFFICE

Houston ESD - Piping

This is to certify that a representative of this Bureau did, at the request of

ROCKWELL AUTOMATION, INC. assess design plans and data for the below listed product. This assessment is a representation by the Bureau as to the

degree of compliance the design exhibits with applicable sections of the Rules. This assessment does not waive unit

certification or classification procedures required by ABS Rules for products to be installed in ABS classed vessels or

facilities. This certificate, by itself, does not reflect that the product is Type Approved. The scope and limitations of

this assessment are detailed on the pages attached to this certificate.

Product: Motor Controller Model: 20L (PowerFlex 700L) This Product Design Assessment (PDA) Certificate 18-HS1781263-PDA, dated 25/Sep/2018 remains valid until 24/Sep/2023 or until the Rules

or specifications used in the assessment are revised (whichever occurs first).

This PDA is intended for a product to be installed on an ABS classed vessel, MODU or facility which is in existence or under contract for

construction on the date of the ABS Rules or specifications used to evaluate the Product.

Use of the Product on an ABS classed vessel, MODU or facility which is contracted after the validity date of the ABS Rules and specifications

used to evaluate the Product, will require re-evaluation of the PDA.

Use of the Product for non ABS classed vessels, MODUs or facilities is to be to an agreement between the manufacturer and intended client.

AMERICAN BUREAU OF SHIPPING

__________________________Dustin De Los Santos

Engineer/Consultant

Page 2: ROCKWELL AUTOMATION, INC....CERTIFICATE NUMBER DATE 18-HS1781263-PDA 25 Sep 2018 ABS TECHNICAL OFFICE Houston ESD - Piping This is to certify that a representative of this Bureau did,

As of 25/Sep/2018Type Approved

ROCKWELL AUTOMATION 6400 WEST ENTERPRISE DRIVE MEQUON WI United States 53092 Telephone: 262--512-2147 Fax: Email: [email protected] Web: www.rockwellautomation.com Tier: 5 - Unit Certification Required

Product: Motor ControllerModel: 20L (PowerFlex 700L)Intended Service: Marine and Offshore Applications - Adjustable Frequency AC Drive Motor Controller for Auxiliary Services onboardVessels and Offshore Platforms. Description: PowerFlex 700L Series Liquid Cooled Variable Speed AC Drive. Rating: 20L General Purpose :- 20LC360 200Kw, 400VAC, 3 Phase, Frame 2- 20LC650 370Kw, 400VAC, 3 Phase, Frame 3A- 20LC1K2 715Kw, 400VAC, 3 Phase, Frame 3B - 20LD360 300Hp, 480VAC, 3 Phase, Frame 2- 20LD650 600Hp, 480VAC, 3 Phase, Frame 3A- 20LD1K2 1150Hp, 480VAC, 3 Phase, Frame 3B - 20LE425 466Hp, 600VAC, 3 Phase, Frame 3A- 20LE800 870Hp, 600VAC, 3 Phase, Frame 3B- 20LE1K1 1275Hp, 600VAC, 3 Phase, Frame 3B - 20LF380 355Kw, 690VAC, 3 Phase, Frame 3A- 20LF705 657Kw, 690VAC, 3 Phase, Frame 3B- 20LF1K0 980Kw, 690VAC, 3 Phase, Frame 3B AIC Rating: 200,000 rms symmetrical amps (Maximum)Enclosure: IP20, NEMA/UL Type 1 Refer to Rockwell Automation Technical Data Publication 20L-TD001C-EN-P November 2015, Pages 6, 7 & 8 fordetail Ratings (Voltage, Current, HP). Service Restriction: - Unit Certification is required for semiconductor converters used to control motor drives having a rated power of 100kW(135 hp) and over intended for essential services as per 4-8-3/5.11 and for propulsion applications as per 4-8-5/5.17.8 of ABS Steel Vessel Rules (2018).- Inspection and testing of equipment should comply with ABS Steel Vessels Rules (2018) 4-8-3/8.7. Comments: - The Manufacturer has provided a declaration about the control of, or the lack of Asbestos in this product. - The units are to have the appropriate enclosure IP rating as per 4-8-3/Table 2 of the ABS Steel Vessels Rules basedon their installed location.- Drives are not intended for installation in hazardous areas. Notes/Drawing/Documentation: Document. PowerFlex700L_CE_DoC, DST-0087-G-EN, dated 11 August 2016, 3 Pages;Document No. PowerFlex700L_tech_data, 20L-TD001C-EN-P, dated November 2015, 48 Pages;Dwg No. 385439-9, Frame 2, 700L Power Section, 13 ShtsDwg No. 180654-9, Assembly, Active Converter Board PowerFlex 700L/LPM20, 2 shts;Dwg No. 314215-9, PowerFlex 700 Vector Encoder Assembly;Dwg No. 314233-9, PF 700 Vector Cassette Control Assembly;

Page 1 of 3

Page 3: ROCKWELL AUTOMATION, INC....CERTIFICATE NUMBER DATE 18-HS1781263-PDA 25 Sep 2018 ABS TECHNICAL OFFICE Houston ESD - Piping This is to certify that a representative of this Bureau did,

As of 25/Sep/2018Type Approved

ROCKWELL AUTOMATION 6400 WEST ENTERPRISE DRIVE MEQUON WI United States 53092 Telephone: 262--512-2147 Fax: Email: [email protected] Web: www.rockwellautomation.com Tier: 5 - Unit Certification Required

Dwg No. 354792-9, Circuit Board Assembly PF 700 Enhanced Encoder Board;- Publication 20L-PP001D-EN-P, August 2007, PowerFlex 700L Drive High Performance & High Power LiquidCooled Power Structure, 2 shts.- Publication 20L-UM001E-EN-P, May 2013, (P/N-203462) PowerFlex 700L Liquid-Cooled Adjustable FrequencyAC Drive, Frames 2, 3A & 3B,- Publication 20L-TD001B-EN-P, June 2013, PowerFlex 700L Technical Data Liquid-Cooled Adjustable FrequencyAC Drives, 47 Pages;- PDM # 1192457, PowerFlex 700L, Frame 2, 300HP, 360 Amp, 480 Volt, DE8100 Overvoltage & Undervoltage Testdated 12 April 2007, 9 Pages;- PDM # 1192460, PowerFlex 700L, Frame 2, 300HP, 360 Amp, 480 Volt, DE8104 Phase Unbalanced Test dated 11April 2007, 9 Pages;- PDM # 1193698, PowerFlex 700L, Frame 2, 300HP, 360 Amp, 480 Volt, DE8105 50/60Hz Power Line FrquencyTest dated 23 Feb 2007, 7 Pages;- PDM # 1179827, PowerFlex 700L, Frame 2, DE8221 & UL508C Shorted Output Test dated 5 & 6 June 2006;- PDM # 1195667, PowerFlex 700L, Frame 2, 300HP, 360 Amp, 480 Volt, EN 50178 Dry Heat Test dated 23 June2007, 6 Pages;- PDM # 1195671, PowerFlex 700L, Frame 2, 300HP, 360 Amp, 480 Volt, EN 50178 Damp Heat Test dated 21 June2007, 7 Pages;- SCA America Report No. 10192.2, Shock & Vibration Test, 4 Pages, dated 16 July 2007;- Tegrant Report No. 10879, Temperature, Drop & Compression Tests, 3 Pages, dated 16 July 2007;- DE8108 Dielectric Voltage Withstand , dated 27 June 2007, PF700LFrame 2, 300HP, 360 Amp, 480 Volt, 4 Pages;- PDM # 1193694, PowerFlex 700L, Frame 2, 300HP, 360 Amp, 480 Volt, DE1002-009, Harmonic CurrentEmissions, dated 17 April 2007, 9 Pages;- LS Research Test Report No. 307159, dated 2-5 April 2007, PowerFlex 700L, Frame 2, Model 20LD360-QUAL07,28 Pages;- DE8127 Electrical Fast Transient Burst Immunity Test, PowerFlex 700L, Frame 2, 300HP, 360 Amp, 480 Volt,dated27 March 2007, 7 Pages;- UL EMC File No. MC8284, dated 6 June 2007, PowerFlex 700L Electromagnetic Compatibility Test Report, 16Pages; Terms of Validity: This Product Design Assessment (PDA) Certificate 18-HS1781263-PDA, dated 25/Sep/2018 remains valid until24/Sep/2023 or until the Rules or specifications used in the assessment are revised (whichever occurs first). This PDA is intended for a product to be installed on an ABS classed vessel, MODU or facility which is in existenceor under contract for construction on the date of the ABS Rules or specifications used to evaluate the Product. Use of the Product on an ABS classed vessel, MODU or facility which is contracted after the validity date of the ABSRules and specifications used to evaluate the Product, will require re-evaluation of the PDA. Use of the Product for non ABS classed vessels, MODUs or facilities is to be to an agreement between themanufacturer and intended client. STANDARDS ABS Rules: The Rules for Conditions of Classification, Part 1 2018 Steel Vessels Rules 1-1-4/7.7, 1-1-A3, 1-1-A4, which coversfollowing:2018 Steel Vessels Rules 4-8-3/1.7, 4-8-3/1.11, 4-8-3/1.17, 4-8-3/8, 4-9-8/Table 1,

Page 2 of 3

Page 4: ROCKWELL AUTOMATION, INC....CERTIFICATE NUMBER DATE 18-HS1781263-PDA 25 Sep 2018 ABS TECHNICAL OFFICE Houston ESD - Piping This is to certify that a representative of this Bureau did,

As of 25/Sep/2018Type Approved

ROCKWELL AUTOMATION 6400 WEST ENTERPRISE DRIVE MEQUON WI United States 53092 Telephone: 262--512-2147 Fax: Email: [email protected] Web: www.rockwellautomation.com Tier: 5 - Unit Certification Required

The Rules for Condition of Classification, Part 1 2018 Offshore Units and Structures 1-1-4/9.7, 1-1-A2, 1-1-A3 whichcovers the following:2018 MODU Rules 4-3-1/11,4-3-1/15, 4-3-1/17, 6-1-7/12 National: N/A International: EU EMC Directive - 2014/30/EU: EN 61800-3:2004 +A1:2012EU Low Voltage Directive (LVD) - 2014/35/EU: EN 61800-5-1:2007 Government: N/A EUMED: N/A OTHERS: N/A

Page 3 of 3