Arc-Resistant, Metal-Clad SafeGear insures
optimum safety and operational reliability.
Medium Voltage Arc Resistant Switchgear
VisiVolt voltage indicato
installed directly on the
bus bar, provides visual
voltage indication for
improved operator safet
Arc resistance offers protection from objects or hot gases that
might be ejected during an arc fault.
Vents and flaps are located on top of the enclosure to release the
pressure. This significantly reduces operator risk during handling
and operation of the equipment.
SafeGears level of arc resistance helps protect workers from the
catastrophic effects of an internal arc fault, and also helps protect
nearby equipment from collateral damage.
More than 25 years experience in arc resistant switchgear
First manufacturer of two-high arc resistant switchgear; the
ABB design allows for flexibility in configurations and promotes
superior safety performance
Small arc resistant footprint allows ABB switchgear to fit into
tighter spaces
Large arc-resistant window allows the operator to check position
and status of circuit breaker without opening the cell door
Available in ratings up to 15 kV, 3,000 A, 50 kA
-
7/29/2019 Safegear Sell Sheet
2/2
Safegear1VAL108001-FLRevA,
March07
Copyright2007ABB
Allrightsreserved
ABB Inc.
655 Century Point
Lake Mary, FL 32746
U.S.A.
Tel + 1 407-732-2000
Fax + 1 407-732-2132
www.abb.com/engineeredforsafety
As the pioneer and most experienced manufacturer
of arc-resistant switchgear in the USA, only ABB can
combine safety and performance that translate into
peace of mind for those who specify, recommend,
and operate electrical equipment.
Call your ABB representative for more details or for a
complete presentation on SafeGear.
Medium Voltage Arc Resistant Switchgear
25%Without Operator
10%With Operator in
front of a closed
door
65%With Operator
working in the
switchgear
Arc Flash characteristics:
An arc arises when at
least part of the current
passes through adielectric, usually air
Maximum peak power up
to 40 MW
Arc temperature up to
five times the surface
temperature of the sun
(20 000C)
Light intensity more than
2000 times that of normal
office light
Volumetric expansion
approximately 40,000
times
Arc Flash Accidents
FEATURES
Closed door racking
Remote breaker racking
Automatic secondary disconnects
IS Limiter
VisiVolt voltage indicator
REA Relay:
- Reduce incident energy
by up to 80%
- Helps meet OSHA, IEEE,
NFPA & NEC standards
- Can reduce Personal
Protection Equipment (PPE)
requirements for easier
maintenance
- Can be used with any
manufacturers relays and
requires no re-programming or
setting changes