Download - Search for new physics from the CERN Axion Solar Telescope (CAST) high-energy calorimeter
![Page 1: Search for new physics from the CERN Axion Solar Telescope (CAST) high-energy calorimeter](https://reader035.vdocument.in/reader035/viewer/2022062322/568150ee550346895dbf070b/html5/thumbnails/1.jpg)
Search for new physics from the Search for new physics from the CERN Axion Solar Telescope CERN Axion Solar Telescope
(CAST) high-energy calorimeter(CAST) high-energy calorimeter
David W. MillerDavid W. Miller
Advisor: Juan I. CollarAdvisor: Juan I. Collar
Bachelor’s thesis DefenseBachelor’s thesis Defense
9 May, 20059 May, 2005
![Page 2: Search for new physics from the CERN Axion Solar Telescope (CAST) high-energy calorimeter](https://reader035.vdocument.in/reader035/viewer/2022062322/568150ee550346895dbf070b/html5/thumbnails/2.jpg)
Roadmap
Origins of the “axion”
The CAST high-energy calorimeter
Systematic detector effects
Data processing and analysis
Limits on new physics
![Page 3: Search for new physics from the CERN Axion Solar Telescope (CAST) high-energy calorimeter](https://reader035.vdocument.in/reader035/viewer/2022062322/568150ee550346895dbf070b/html5/thumbnails/3.jpg)
Origins of the “axion”
The CAST high-energy calorimeter
Systematic detector effects
Data processing and analysis
Limits on new physics
![Page 4: Search for new physics from the CERN Axion Solar Telescope (CAST) high-energy calorimeter](https://reader035.vdocument.in/reader035/viewer/2022062322/568150ee550346895dbf070b/html5/thumbnails/4.jpg)
• A zero neutron electric dipole moment implies lack of CP-violation in QCD
• This anomalous result needed a cause, since there is no reason NOT to have CP-violation in QCD
• Roberto Peccei (UCLA) & Helen Quinn (Stanford) proposed a symmetry which explains this result
• Frank Wilczek (MIT) noticed this leads to a new pseudoscalar boson: the AXION was born (he named it after a laundry detergent)
““One needed a particle to clean up a problem…”One needed a particle to clean up a problem…”-- Frank Wilczek-- Frank Wilczek
The story of the axion
![Page 5: Search for new physics from the CERN Axion Solar Telescope (CAST) high-energy calorimeter](https://reader035.vdocument.in/reader035/viewer/2022062322/568150ee550346895dbf070b/html5/thumbnails/5.jpg)
Axion Phenomenology
• Interaction with photons– Inside of a magnetic field,
the axion can convert into a real photon (Primakoff effect)
– Reverse process possible tooReverse process possible too
• Nuclear transitions– Axions can be emitted
during certain nuclear transitions instead of γ’s
These theoretical suggestions have experimental consequences– This new particle can interact with photons
– Can even substitute for photons in certain situations
![Page 6: Search for new physics from the CERN Axion Solar Telescope (CAST) high-energy calorimeter](https://reader035.vdocument.in/reader035/viewer/2022062322/568150ee550346895dbf070b/html5/thumbnails/6.jpg)
Sources of axions: astrophysical and otherwise
• Big bang– would be a very light axion– could constitute a fraction of the dark
matter• Photon interactions
– Photon-axion oscillations in magnetic fields such as those in plasma of stars
– Would result in a spectrum of energies • Nuclear reactions
– Nuclear transitions such as in stellar collapse, fusion reactions, excited nuclei
– Would result in mono-energetic axions at slightly higher energies (MeV)
– Searches can look for anomalous peaks
Better energy Better energy scale and scale and
Stars are a Stars are a good source!good source!
Too lightToo lightfor ourfor oursearchsearch
![Page 7: Search for new physics from the CERN Axion Solar Telescope (CAST) high-energy calorimeter](https://reader035.vdocument.in/reader035/viewer/2022062322/568150ee550346895dbf070b/html5/thumbnails/7.jpg)
Solar axionsPrinciple of detection
axions
Transv
erse m
agnetic field (B
)
γ
γ dete
ctor
→ AXION-PHOTON CONVERSION
L
![Page 8: Search for new physics from the CERN Axion Solar Telescope (CAST) high-energy calorimeter](https://reader035.vdocument.in/reader035/viewer/2022062322/568150ee550346895dbf070b/html5/thumbnails/8.jpg)
axions
Transv
erse m
agnetic field (B
)
γ
γ dete
ctor L
Probability of Conversion:
22LBP
![Page 9: Search for new physics from the CERN Axion Solar Telescope (CAST) high-energy calorimeter](https://reader035.vdocument.in/reader035/viewer/2022062322/568150ee550346895dbf070b/html5/thumbnails/9.jpg)
Origins of the “axion”
The CAST high-energy calorimeter
Systematic detector effects
Data processing and analysis
Limits on new physics
![Page 10: Search for new physics from the CERN Axion Solar Telescope (CAST) high-energy calorimeter](https://reader035.vdocument.in/reader035/viewer/2022062322/568150ee550346895dbf070b/html5/thumbnails/10.jpg)
The CAST high energy-calorimeter
Motivation• A new particle like the axion might be emitted in nuclear
reactions within the sun• Such particles (like axions) should convert into real
(detectable) photons in the right situations
Goal• Maximize sensitivity to high energy (MeV) axion signal via
axion-to-photon conversionsaxion-to-photon conversions in laboratory magnetic field (for example, at CERN)
• Search for other new particles like the axion• Must maintain minimalist design due to CAST constraints
![Page 11: Search for new physics from the CERN Axion Solar Telescope (CAST) high-energy calorimeter](https://reader035.vdocument.in/reader035/viewer/2022062322/568150ee550346895dbf070b/html5/thumbnails/11.jpg)
Front ViewFront View
Side ViewSide View
Plastic Muon Plastic Muon VetoVeto
CWO Crystal
light
guide
Low-bckg PMTLow-bckg PMT
Brass support tubeBrass support tube
ThermocoupleThermocoupleplacementplacement
Ultra-low bckg PbUltra-low bckg Pb
Incoming gammasIncoming gammas(from magnet bore)(from magnet bore)
Pb shieldingPb shielding
γ’s
Muon veto PMTMuon veto PMT
Characteristic pulse
50μsrate~4 Hz
![Page 12: Search for new physics from the CERN Axion Solar Telescope (CAST) high-energy calorimeter](https://reader035.vdocument.in/reader035/viewer/2022062322/568150ee550346895dbf070b/html5/thumbnails/12.jpg)
Calorimeter design
• Low intrinsic BCKG CdWO4 crystal scintillator
• Rn purging with N2 flow
• 200 MeV dynamic range• 12.8% resolution at 835
keV• 93% livetime• 4 Hz raw counting rate on
surface
![Page 13: Search for new physics from the CERN Axion Solar Telescope (CAST) high-energy calorimeter](https://reader035.vdocument.in/reader035/viewer/2022062322/568150ee550346895dbf070b/html5/thumbnails/13.jpg)
Chicago calorimeter
adjustable platform for alignment
MicroMegas X-ray Detector
X-ray Telescope
Calorimeter installation on LHC magnet platform
Magnet Platfo
rm
![Page 14: Search for new physics from the CERN Axion Solar Telescope (CAST) high-energy calorimeter](https://reader035.vdocument.in/reader035/viewer/2022062322/568150ee550346895dbf070b/html5/thumbnails/14.jpg)
Origins of the “axion”
The CAST high-energy calorimeter
Systematic detector effects
Data processing and analysis
Limits on new physics
![Page 15: Search for new physics from the CERN Axion Solar Telescope (CAST) high-energy calorimeter](https://reader035.vdocument.in/reader035/viewer/2022062322/568150ee550346895dbf070b/html5/thumbnails/15.jpg)
Systematic effects±8±8oo
±40±40oo
the calorimeterthe calorimeter
![Page 16: Search for new physics from the CERN Axion Solar Telescope (CAST) high-energy calorimeter](https://reader035.vdocument.in/reader035/viewer/2022062322/568150ee550346895dbf070b/html5/thumbnails/16.jpg)
Temperature and Position
• Gain fluctuations inevitable → must correct for this!
• Environmental 40K peak automatically located and fitted every ~2.7 hrs
• Gain shifted to correct value
• Position dependence of the detector evident
• Correct for this by only comparing data taken from same positions
High energy muonposition dependence
![Page 17: Search for new physics from the CERN Axion Solar Telescope (CAST) high-energy calorimeter](https://reader035.vdocument.in/reader035/viewer/2022062322/568150ee550346895dbf070b/html5/thumbnails/17.jpg)
Temperature and Position
With correction for position
• Gain fluctuations inevitable → must correct for this!
• Environmental 40K peak automatically located and fitted every ~2.7 hrs
• Gain shifted to correct value
• Position dependence of the detector evident
• Correct for this by only comparing data taken from same positions
![Page 18: Search for new physics from the CERN Axion Solar Telescope (CAST) high-energy calorimeter](https://reader035.vdocument.in/reader035/viewer/2022062322/568150ee550346895dbf070b/html5/thumbnails/18.jpg)
Origins of the “axion”
The CAST high-energy calorimeter
Systematic detector effects
Data processing and analysis
Limits on new physics
![Page 19: Search for new physics from the CERN Axion Solar Telescope (CAST) high-energy calorimeter](https://reader035.vdocument.in/reader035/viewer/2022062322/568150ee550346895dbf070b/html5/thumbnails/19.jpg)
Data processing of final data set
• Final data sets (background and signal) must account for systematic detector effects– Gain shifted to correct for energy fluctuations
– Position normalization
• Should eliminate as much noise and unwanted events as possible– Use shape of pulse to eliminate these
• Pulse shape discrimination (PSD)
![Page 20: Search for new physics from the CERN Axion Solar Telescope (CAST) high-energy calorimeter](https://reader035.vdocument.in/reader035/viewer/2022062322/568150ee550346895dbf070b/html5/thumbnails/20.jpg)
Software cuts• Use γ calibrations to
determine software cuts– Keep 99.7%!!!!!!
• Set cuts for:– Energy
– Shape of Pulse• PID = pulse identification
parameter
– Pulse rise time
![Page 21: Search for new physics from the CERN Axion Solar Telescope (CAST) high-energy calorimeter](https://reader035.vdocument.in/reader035/viewer/2022062322/568150ee550346895dbf070b/html5/thumbnails/21.jpg)
Pulse shape discrimination
![Page 22: Search for new physics from the CERN Axion Solar Telescope (CAST) high-energy calorimeter](https://reader035.vdocument.in/reader035/viewer/2022062322/568150ee550346895dbf070b/html5/thumbnails/22.jpg)
Pulse shape discrimination
![Page 23: Search for new physics from the CERN Axion Solar Telescope (CAST) high-energy calorimeter](https://reader035.vdocument.in/reader035/viewer/2022062322/568150ee550346895dbf070b/html5/thumbnails/23.jpg)
Pulse shape discrimination
~50% reduction~50% reduction
![Page 24: Search for new physics from the CERN Axion Solar Telescope (CAST) high-energy calorimeter](https://reader035.vdocument.in/reader035/viewer/2022062322/568150ee550346895dbf070b/html5/thumbnails/24.jpg)
Details for this data set
• Total Running Time = 1257.06 hrs (53 days)• Tracking Time = 60.2756 hrs (2.5 days)• Background Time = 897.835 hrs (37 days)• Normalized BCKG Time = 117.341 hrs (4.9 days)• Systematics Time = 298.947 hrs (12 days)
– valves open, quenches, etc.
• Ratio of Norm BCKG to Total BCKG = 0.13• Ratio of Tracking to Total BCKG = 0.07
![Page 25: Search for new physics from the CERN Axion Solar Telescope (CAST) high-energy calorimeter](https://reader035.vdocument.in/reader035/viewer/2022062322/568150ee550346895dbf070b/html5/thumbnails/25.jpg)
Energy spectrum
• Without position normalized background data– Good agreement, butbut we know there
is a systematic effect due to the pointing position of the magnet
• With position normalization– Error bars increase by factor x2
– Systematic effect of position reduced
![Page 26: Search for new physics from the CERN Axion Solar Telescope (CAST) high-energy calorimeter](https://reader035.vdocument.in/reader035/viewer/2022062322/568150ee550346895dbf070b/html5/thumbnails/26.jpg)
Data treatment and results
Data treatmentData treatment
ResultResult
% data % data keptkept
BCKG BCKG Count rate Count rate
(Hz)(Hz)
Integ. Integ. Flux Flux
(cm(cm-2-2secsec-1-1))
Raw data 100 3.82 0.263
Anti-coincidence with muon veto 63.4 2.42 0.167
Recursive 40K peak gain shifting 63.4 2.42 0.167
PSD analysis and cuts
(incl. livetime pulser removal)37.4 1.43 0.1
FULL DATA TREATMENT 37.4 1.43 0.1
![Page 27: Search for new physics from the CERN Axion Solar Telescope (CAST) high-energy calorimeter](https://reader035.vdocument.in/reader035/viewer/2022062322/568150ee550346895dbf070b/html5/thumbnails/27.jpg)
Residual spectrumDifference between signal and background
Low energy0.3 – 3 MeV
Mid energy3 – 10 MeV
High energy10 – 50 MeV
![Page 28: Search for new physics from the CERN Axion Solar Telescope (CAST) high-energy calorimeter](https://reader035.vdocument.in/reader035/viewer/2022062322/568150ee550346895dbf070b/html5/thumbnails/28.jpg)
Origins of the “axion”
The CAST high-energy calorimeter
Systematic detector effects
Data processing and analysis
Limits on new physics
![Page 29: Search for new physics from the CERN Axion Solar Telescope (CAST) high-energy calorimeter](https://reader035.vdocument.in/reader035/viewer/2022062322/568150ee550346895dbf070b/html5/thumbnails/29.jpg)
Look for evidence buried in data
• Signal: mono-energetic peaks– Width determined by
detector resolution
• Obtain 95% CL (2σ) for allowed anomalous events at each energy
• Still need to correct for:– Livetime– Gamma capture efficiency– Transmission through X-ray
detector
Best fit (signal)Best fit (bckg)Best fit (sig+bckg)
95% CL peak
![Page 30: Search for new physics from the CERN Axion Solar Telescope (CAST) high-energy calorimeter](https://reader035.vdocument.in/reader035/viewer/2022062322/568150ee550346895dbf070b/html5/thumbnails/30.jpg)
Allowed anomalous events at 95% CL
![Page 31: Search for new physics from the CERN Axion Solar Telescope (CAST) high-energy calorimeter](https://reader035.vdocument.in/reader035/viewer/2022062322/568150ee550346895dbf070b/html5/thumbnails/31.jpg)
CAST Limits on the axion
Example calorimeter limits
![Page 32: Search for new physics from the CERN Axion Solar Telescope (CAST) high-energy calorimeter](https://reader035.vdocument.in/reader035/viewer/2022062322/568150ee550346895dbf070b/html5/thumbnails/32.jpg)
Detector Parameters
Resolution versus energy Efficiency for full energy deposition