SECTION D
COMPRESSOR NOMENCLATURE
TOPICSWelded Compressors .................................................. D2HFC Welded Compressors .......................................... D4A-Line .......................................................................... D6CRKQ, CIKQ ............................................................... D8CR7, CR6, CRKF, CS, CF ......................................... D10Copelametic® ............................................................. D12Copeland Discus™ ..................................................... D14Refrigeration Copeland Scroll® .................................. D16A/C Copeland Scroll® ................................................. D18Condensing Unit (All models except M-Line) ............ D20M-Line Condensing Unit ............................................ D22
This section contains current information on Copeland® products. Information on obsolete models can be obtained from your local Emerson Climate Technologies wholesaler.
For individual model designations, visit On-Line Product Information at www.emersonclimate.com.
D2
NOMENCLATURE • WELDED COMPRESSORS
Code Description
EFRTS
= High Effi ciency= Low Temperature= High Temperature= Two Speed= Medium Temperature
CompressorFamily SeriesEither a number or a letter established for each product model.
DisplacementA letter only, arbitrarily assigned for each different displacement within any one family series.
Comp. Motor Rating
Nominal (HP)
Code
¼1/3½½¾11
1-1/41-1/21-3/4
22-1/42-3/4
33-1/2
44-1/2
57-1/2
91012
0025003300500051007501000100012501500175020002250275027503500400045005007500090010001200
X X X X - X X X X
Model VariationA number only, assigned to indicate different model types within any one family series.
D3
NOMENCLATURE • WELDED COMPRESSORS
Compressor Motor Types
Phase Description Code
1 Capacitor Run - Capacitor Start C
1 Induction Run - Capacitor Start I
1 Capacitor Run - Permanent Split Capacitor
P
3 Three Phase T
Compressor Motor Protection
Type Protection Code
External Inherent Protection-One Protector (Line Break)Use with Contactor
A
Internal Thermal Protection – Electronic Sensors; andControl Module ExternalUse with Contactor
S
Internal Inherent Protection – One Protector (Line Break) F
Electrical Codes
60 HZ 50HZ Code
115-1230-1208/230-3460-3575-3265-1208/230-1200/230-3
-200/240-1200/220-3380/420-3500-3220/240-1380/420-3200-1220/240-1200/240-3
ABCDEJMVZ5
(Refer to model data or nameplate for specifi c nominal voltage.)
Product VariationsNumbers will be assigned asfollows:1. Number – 100 is standard compressor used in
Copeland brand Condensing units.2. Number – 200 indicates a STANDARD Com-
pressor and Component Parts B/M and Model No.
3. Number – 700 and –900 series indicate OEM and Wholesaler service B/M and model number.
4. Number – 201 and larger will be assigned for all other variations of a given model.
- X X X - X X X
D4
NOMENCLATURE • HFC WELDED COMPRESSORS
Oil Identifi er“E” designates Polyol Ester. No digit if Mineral Oil
X X X X X X X
Model VariationA number or letter, assigned to indicate different model types within any one family series.
Compressor nominal capacity at rating conditions to two signifi cant digits.
Capacity MultiplierC = 100K = 1000
Compressor Family SeriesEither a number or a letter established for each product model.
Code Description
R
SFTV
=High or Medium Temperature, Air Conditioning and Heat Pump=Medium Temperature=Low Temperature=Two Speed=Variable Speed
D5
NOMENCLATURE • HFC WELDED COMPRESSORS
- X X X - X X X
Bill of Material Product Variations
Compressor Motor Types
Phase Description Code
1113
Capacitor Run – Capacitor Start Induction Run – Capacitor Start
Capacitor Run – PermanentCapacitor Run – Split Capacitor
CIPT
Typical Electrical Codes
60 HZ 50HZ Codes
115-1230-1
208/230-3460-3575-3265-1
- -
208/230-1 -
200/230-3
-200/240-1200/230
380/420-3550-3
220/240-1220/240-3380/420-3
200-1220/240-1200/240-3
ABCDEJRMVZ5
(Refer to model data or nameplate for specifi c nominal voltage.)
Compressor Motor Protection
Type Code
External Inherent Protection-One Protector (Line Break)
Use with Contactor
A
Internal Inherent Protection-One Protector (Line Break)
Use with Contactor
F
D6
NOMENCLATURE • A-LINE COMPRESSORS
Compressor Shell Series
A S E 2 4 C 3 E
Oil Identifi er“E” designates Polyol Ester.
Model Series VariationA number or letter arbitrarily assigned to indicate different model types within any one family series.
Capacity MultiplierC: 100
K: 1,000
CapacityCompressor nominal capacity at 60 Hertz rating condition to two signifi cant digits.
Compressor Family Series
Application Range
Code Description Rating Point
S
FR
Medium & ExtendedTemperature R-404A, R-22Extended Medium R-134a, R-404AHigh Temperature R-134a
20/120
-10/12045/130
D7
NOMENCLATURE • A-LINE COMPRESSORS
- I A A – 2 0 1
Product VariationsThree-digit Bill of Mate-rial number that indicates compressor confi guration and may include accessories.
Compressor Motor Protection
Type Protection Code
Internal Thermal Protection – Electronic Sensors; and ControlModule External
S
Internal Inherent Protection – One Protector (Line Break)Use with Contactor
F
External Inherent Protection – One Protector (Line Break)Use with Contactor
A
BTU Model Families
A R CRK6 CRKQ CS
22134a404A507
XX
XXX
X X XXXX
Voltage Ranges (Typical)
Voltage 60 Hertz Rating 50 Hertz Rating
Family Code Rating Min. Max. Rating Min. Max.
C, RAAllAllAllAllC, RAC, RAAllC
AACDEJVVZZ5T
115-1115-1208/230-3460-3575-3265-1208/230-1208/230-1--200/230-3-
103103207414518239197187
--
187-
127127253506633292253244
--
253-
-100200/220-3380/420-3500-3220/240-1200-1200-1220/240-1220-240-1200-240-3200/240-1
-90180342450198180180198198180180
-110240462550264200220264254264252
Compressor Motor Types
Phase Description Code
111
31
Capacitor Run – Capacitor StartInduction Run – Capacitor StartCapacitor Run – Permanent Split CapacitorThree PhaseInduction Run – Split Phase
CIP
TS
D8
NOMENCLATURE • CRKQ, CIKQ MODELS
X X X X X X E
Indicates compressors with polyol ester oil.
CapacityCompressor nominal 60 Hertz capacity at ARI rating condition to two signifi cant digits.
Compressor Family SeriesLetter “C” established for this family of compressors.
Model Series VariationLetter “Q” assigned to indi-cate “Quiet Compressors.”
Application RangeCode Description R High and medium temp.
Capacity MultiplierK = 1000
D9
NOMENCLATURE • CRKQ, CIKQ MODELS
- X X X - X X X X X
Product VariationsThree-digit Bill of Mate-rial number that indicates compressor confi guration and accessories included.
Compressor Motor Types
Phase Description Code
1
3
Capacitor Run – Permanent Spilt CapacitorThree PhaseGeneral-3 Lead Single Voltage6 Lead Part Winding
P
T
External VariationsOptional alpha letters that indicate external ac-cessories.
Typical Electrical Codes
50 HZ 60 HZ Code
200-1200/240-1220/240-1380/420-3200/240-3
208/230-1--460-3200/230-3
VTZD5
Compressor Motor Protection
Type Protection Code
Internal inherent protection – One protector, Use with contactor(single or three phase)
F
D10
NOMENCLATURE • CR7, CR6, CRKF, CS, CF MODELS
X X X X X X E
Capacity MultiplierK = 1000
Model VariationA number or letter, assigned to indicate different model types within any one family series.
Indicates compressors with polyol ester oil.
Compressor nominal capac-ity at rating conditions to two signifi cant digits.
Compressor Family SeriesEither a number or a letter established for each product model.
Application Range
Code Refrig. Description
I, R R-22High Temp.A/C & Heat Pump
S R-404A/R-22/R-134a/R-507
Med. Temp.Refrigeration
FR-404A/R-507 Low Temp.
Refrigeration
P R-410A High Temp.High Pressure
D11
NOMENCLATURE • CR7, CR6, CRKF, CS, CF MODELS
- X X X - X X X
Product VariationsNumbers will be assigned as follows:1. Number –105 indicates a standard B/M with
molded plug connection and a straight discharge and suction fi tting.
2. Number –130 indicates standard B/M with molded plug.
3. Number –230 indicates a standard compressor B/M and model number.
4. Number –270 indicates a standard compressor B/M with crankcase heater.
5. Number –500 series indicates international standard compressor B/M and model number.
6. Number –730 indicates a standard OEM service B/M and model number.
7. Number –700 and –900 series indicate standard OEM and Wholesaler service B/M and model number.
8. Number –830 indicates a standard OEM service B/M with a molded plug.
Compressor Motor Types
Phase Description Code
1 Capacitor Run – Permanent Split Capacitor P
3
Three PhaseGeneral – 3 Lead Single Voltage 6 Lead Part Winding (575 Volt)
T
Electrical Codes
60 Hz. 50 Hz. Code
208/230-3460-3575-3265-1-208/230-1---200/230-3
200/220-3380/420-3500-3220/240-1380/420-3200/220-1220/240-1360/460-3180/260-1200/240-3
CDEJMVZ1*2*5
* Wide voltage range for India produced products
Compressor Motor Protection
Type Protection Code
Internal Inherent Protection – One Protector (Single or three phase)
F
D12
NOMENCLATURE • COPELAMETIC MODELS
K A T A – 0 1 0 0
Refrigerant-Cooled Code Description R = Std. Refrig. Cooled
Water-Cooled Code Description W = Std. Water Cooled
Air-Cooled Code Description A = Std. Air Cooled
Model VariationA number assigned to indi-cate major variations within any one family series.
Displacement and Valve PlateA letter only, assigned for each different displacement valve plate combination within any one family series.
Compressor Family SeriesEither a number or a letter established for each product model.
Comp. Motor Rating
Nominal (HP) Code
1/3½½¾1
1-1/222333452025303540
003300500051007501000150020002100300031003110400050020002500300035004000
D13
NOMENCLATURE • COPELAMETIC MODELS
- C A V - 2 0 1
Product VariationsNumbers will be assigned as follows:1. Number –100 is standard compressor used in
Copeland brand Condensing Units.2. Number –200 indicates a STANDARD Compressor
Parts B/M and Model No.3. Number –201 and larger will be assigned for all
other variations of a given model.4. Number –800 indicates a standard replacement
Compressor and Component Parts B/M and Model No. –240 volt control.
5. Number –801 indicates a standard replacement Compressor and Component Parts B/M and Model No. –120 volt control.
Compressor Motor Types
Phase Description Code
1 Capacitor Run – Capacitor Start C
1 Induction Run – Capacitor Start I
3 Three Phase T
3 Wye (star) Delta E
3 6 Lead Part Winding or Across The Line – except 575V
F
Compressor Motor Protection
Type Protection Code
External Inherent Protection-One Protector, (Line Break)Use with Contactor
A
Internal Inherent Protection-One Protector (Line Break)Use with Contactor
F
Internal Thermal Protectors-Electronic Sensors; and ControlModule ExternalUse with Contactor
S
Electrical Codes
60 Hz. 50 Hz. Code
115-1230-1208/230-3460-3575-3208/230/460-3--230/460-3200-3208/230-1-200/220/380-3
--200/220-3380/420-3550-3200/380/400-3210/240/380/420-3380/420-3200/400-3-200/220-1220/240-1200/380-3
ABCDEKLMNUVZ8
D14
NOMENCLATURE • COPELAND DISCUS MODELS
X X X X X X X X X
Tandem Style ModelsIndicated by the digit representing the comp. model series connectedin tandem with a comp. of the model series indicated by the fi rst digit.
Compressor Cooling
Code Description
A D R T W
Air cooled DiscusRefrigerant cooledStd. two stageWater cooled
Model VariationEither a number or a letter assigned to indicate major variations within any one family series.
Displacement and Valve PlateA letter only, arbitrarily assigned for each different displacement valve plate combination within any one family series
Compressor Family SeriesEither a number of a letter extablished for each product family.
May also be “0” (Mineral Oil) “E” (POE Oil) “L” (Less Oil)
Capacity MultiplierK - 1,000
M - 10,000
Nominal Capacity at Rating Condition 2 numeric characters
Primary Application RangeR = ARI High Temp, Rated @ 45/130S = ARI Med Temp, Rated @ 20/120F = ARI Low Temp, Rated @ -25/105
D15
NOMENCLATURE • COPELAND DISCUS MODELS
- X X X X X X
Product VariationsNumbers will be assigned as follows:1. Numbers -001 through -199 are reserved for
sub-b/m numbers.2. Numbers -200 indicates a standard compressor
and component parts b/m and model no.3. Numbers -201 and larger will be assigned for all
other variations of a given model.
Compressor Motor Protection
Type Protection Code
External inherent protection-one protector (line break) use with contactor
Internal inherent protection-one protector use with contactor
Internal thermostat(s); and ext. supplementary protector(s) use with contactor
Internal thermostat(s); and three ext. supplementary protectors use with contactor
Internal thermal protectors-electronic sensors; and control module external. Use with contactor.
Internal thermal protectors-elec-tronic sensors; and control mod-ule external. Use with contactor (For European use only)
A
F
H
L
S
W
Electrical Codes
60 Hz. * 50 Hz. (Typical) Code
115-1230-1208-230-3 460-3575-3 - - - -208-1 - -208/230/460-3 - - - -230/460-3 - - - - - - - -200-3208-230-1 - -Misc. A.C. Ratings - - - -200-1100-1200-230-3230-3380200/220/380
100-1 200-1 200/220-3 380/400-3 500-3 115-1 230-1 200-1 208/230-1 200/400-3 210/240/380-3 380/420-3 200/400-3 200/380-3 200/240-3 220-1 200-1 - - 200-1 200/220-3 X 500-3 220/240-1 200-1 100-1 - - - - 346 200/346
ABC DEFGHIKLMNPRSTUVW YZ345678
Compressor Motor Types
Single Phase Motors Code
Capacitor run - capacitor startInduction run - capacitor startInduction run - split phaseInduction run - capacitor start, low torque
CISX
Three Phase Motors Code
General 3 Lead single voltage 6 Lead part winding (575 volt) 9 Lead dual voltageStar (wye) delta6 Lead motors Part winding or across the line
T
E
F
D16
NOMENCLATURE • REFRIGERATION SCROLL MODELS
X X X X X X X X X
Compressor Family SeriesEither a number or a letter established for each product model.
Z = Scroll
Capacity Multiplier M: 10,000 K: 1,000 C: SCFM
Type of OilG = PAGE = POE
“blank” = Mineral OilCompressor nominal capac-ity at rating conditions to two signifi cant digits
Model VariationA number or letter, assigned to indicate different model types within any one family series.
Application Range
Code Description
B
SF
CMNXH
High/Medium TemperatureMedium Temp.Low Temp. with Injection portHeliumMarinizedGas BoosterAsia Condensing UnitHeat Pump
Optional Modulation
Code Description
DHHV
DigitalHorizontalHorizontal Variable Speed
D17
NOMENCLATURE • REFRIGERATION SCROLL MODELS
- X X X - X X X
Product VariationsNumbers will be assigned as follows:1. 230/231 - Standard Compressor & Component
Parts w/ Flag Terminal 2. 250/251 - Standard Compressor & Component
Parts w/ Screw Terminal 3. 240/241 - Rotalock Compressor & Component
Parts w/ Flag Terminal 4. 261/265 - Rotalock Compressor & Component
Parts w/ Screw Terminal 5. 900 series indicates standard OEM and
wholesaler service.6. Other numbers designate variations.
Compressor Motor Types
Phase Description Code
1 Capacitor Run – Permanent Split Capacitor
P
3 General3 Lead Single Voltage6 Lead Part Winding (575 Volt)
T
Voltage Ranges (Typical)
Voltage 60 Hertz Rating 50 Hertz Rating
Code Rating Min. Max. Rating Min. Max.
CDEV57JR
208/230-3460-3575-3208/230-1200/230-3380-3265-1-
187414518197180342239-
253506633253253418292-
200-3380/420-3500-3200-1200/220-3-220/240-1220/240-3
180342450180180-198180
220462550220242-264264
Compressor Motor Protection
Type Protection Code
Internal Inherent Protection-
One Protector Use with Contactor(Single or Three Phase)
F
External Electronic Protection
(Three Phase)
W
D18
NOMENCLATURE • A/C SCROLL MODELS
X X X X X X X X X
Compressor Family SeriesEither a number or a letter established for each product model.
Capacity MultiplierK: 1,000
M: 10,000
Type of OilE – 3MA POE OilCompressor nominal capacity at
rating conditions 2 – 3 numeric characters.
ModulationD – DigitalDU – Digital Uneven TandemDT – Digital Even TandemH – HorizontalI – HeatingJ – Digital HeatingS – UltraTechT – Even TandemU – Uneven TandemV – Velocity Variable
Model VariationA number or a letter, assigned to indicate different model types within any one family series.
Application Range
Code Refrig. Description
P R-410A High TemperatureUltra High Pressure
R R-22/407C/134a High Temperature
D19
NOMENCLATURE • A/C SCROLL MODELS
- X X X - X X X
Product Variations1. 130/135/160 - Molded Plug2. 230/235/260 - Quick Terminals T-box3. 250/265 - Screw Terminals T-box4. 7xx/9xx - T-box Service5. 8xx - Molded Plug Service
Compressor Motor Types
Phase Description Code
1 Capacitor Run – Permanent Split Capacitor
P
3 General3 Lead Single Voltage6 Lead Part Winding (575 Volt)
T
Electrical Codes
60 Hz. 50 Hz. Code
208/230-3460-3575-3265-1--208/230-1Misc.200/230-3380-3
200-3380/420-3-220/240-1380-420-3220/240-3-Misc.200/220-3-220/240-1
CDEJMRVX57Z
Compressor Motor Protection
Type Protection Code
Internal Inherent Protection-One Protector Use with Contactor(Single or Three Phase)
F
External Electronic Protection-Kriwan Module(Three Phase)
W
D20
NOMENCLATURE • CONDENSING UNIT
X X X X - X X X X
Condensing Unit Family Series
Design Series and Refrigerant
Letters (Except K,L,M)K, LMNumbers (Except 6 & 7)6, 7X, 9
R-12R-22 LTR-22 LT DiscusR-22/R-502R-12/R-502Special Design
(Different series type may indicate a major design revision.
New HFC Refrigerant Indicator
Pressure Rating Approved Refrigerants
Standard Models
Special Designs
MediumHigh and MediumHigh
TPJ
RNE
Type of Design
Type Code
Air CooledNo condenserWater cooledEvaporating Pan BaseDiscus
ANWED
Typical Motor Rating
Nominal (HP) Code
1/41/31/23/41
1-1/22
2-1/23
3-1/2456
7-1/29101520222527304050607080
002500330050007501000150020002500300035004000500060007500900100015002000220025002700300040005000600070008000
*NOTE: Left hand position may contain a letter indicating a revision (on units less than 10 HP).Right hand position may contain the letter “Z” indicating a Gla-cier™ scroll compressor.
Application Temperature*
Temperature Range Code
High Temperature45ºF Max.; 0ºF Min. H
Medium Temperature25ºF Max.; -5ºF Min. M
Medium Temperature25ºF Max.; -25ºF Min. F
Low Temperature0ºF Max.; -40ºF Min. L
Extra Low Temperature-20ºF Max.; -40ºF Min. E
Two Stage0ºF Max.; -40ºF Min. T
Two Stage (Extra Low)-30ºF Max.; -80ºF Min. U
Commercial ApplicationHigh & Med. TemperatureSingle Refrigerant
C
Dual ApplicationR-22 HT, R-502 MT D
Multiple ApplicationR-12 H/MT, R-502 LT B
NOTE: Limited or extended range will be shown in performance data tables.
All Models Except M-Line
D21
NOMENCLATURE • CONDENSING UNIT
- X X X - X X X
Compressor Motor Type
Single Phase Motors Code
Capacitor Run-Capacitor StartInduction Run-Capacitor StartInduction Run-Split PhaseInduction Run-Capacitor Start, Low TorqueCapacitor Run-Permanent Split Capacitor
CISXP
Three Phase Motors Code
General 3 Lead Single Voltage 6 Lead Part Winding 575 V 9 Lead Dual VoltageStar (Wye) Delta6 Lead Motors Part Winding or Across the Line
T
EF
Bill of Material Product Variations
Variation (B/M) Number UL/CSA Eligibility
001 thru 099 Intended for UL Listing and CSA Certifi ed.
100 thru 299 Intended for UL Recogni-tion and CSA Certifi ed.
300 thru 399 Not Eligible for either UL Listing, LU Recognition, or CSA Certifi ed.
Compressor Motor Protection
Type Protection Code
External InherentProtection – One Protector,(Line Break)Use with Contactor(single or three phase)
A
Internal InherentProtection – One Protector, Usewith Contactor.(single or three phase)
F
Internal Thermostat(s);and External Supple-mentary Protector(s).(Two for 3Ø, one for 1Ø.)Use with Contactor.
H
Internal Thermostat(s);and Three External Supplementary Protectors. Use with Contactor.
L
Internal Thermal Protectors – Electronic Sensors; and Control Module External.Use with Contactor.
S
Internal Thermal Protectors – Electronic sensors; and control module external. Use with contactor. (For European use only).
W
Typical Electrical Codes
60 Hz. 50 Hz. Code
115-1230-1208/230-3460-3575-3--208-1-265-1208/230/460-3--230/460-3All D.C. Ratings----200-3208/230-1-Misc. A.C. Ratings--200-1100-1200/230-3230-3
100-1200-1200/220-3380/400-3500-3115-1230-1200-1208/230-1220/240-1200/400-3210/240/380-3380/420-3200/400-3
200/380-3200/240-3220-1200-1-200-1200/220-3
200/220-3220/240-1200-1100-1--
ABCDEFGHIJKLMNOPRSTUVWXYZ3456
*NOTE: When applicable, specifi c 50 Hz ratings (not necessarily identical to typical shown above) will be shown as alternate on 60 Hz rated models.
D22
NOMENCLATURE • M-LINE CONDENSING UNIT
M A A H -
CFC & HCFC Construction & Refrigerant Indicator(All Model Codes Signify UL Recognized Units)
R-12 R-22R-502 Receiver
Construction StylePower Cord
Fan Guard BX
AGIJKLUV
EMYDPQST
X
X
X
X
XXXX
XX
XX
XX
XX
Indicates M-Line Condensing Unit
Series
Base SizeA – 13” x 17” SteelB – 10” x 12” SteelE – 14-1/4” x 16” CopevapF – 12” x 17-1/2” SteelG – 10” x 21” SteelH – 6-1/2” x 15-1/2” SteelK – 15-1/2” x 18” SteelN – 10” x 12” CopevapP – 11” x 20” CopevapY – 10-1/4” x 14” Steel
Temperature ApplicationH High TemperatureM Medium TemperatureL Low Temperature
New HFC Refrigerant Indicator No reference to Construction and UL or CSA
Pressure Rating of Approved Refrigerants M-Line
MediumHigh and MediumHigh
234
D23
NOMENCLATURE • M-LINE CONDENSING UNIT
- 0 033 - IAA - XXX
Common Bill of Material Variations
CFC & HCFC Models
010100’s200’s
Wholesale (Single Pack)OEM (Single Pack)OEM (Multi Pack)
HFC Models
New HFC products have the same B.O.M. structure as F-Line.
Hot Gas Evaporator Tube
OEM
No TubeEpoxy Coated Copper TubeMonel Tube
Voltage (Start Torque)
IAASAAPAAIAVCAVIASIAZSAZ
115-1-60115-1-60115-1-60208/230-1-60208/230-1-60220-1-50220/240-1-50220/240-1-50
(High)(Low)(Low)(High)(High)(High)(High)(Low)
Nominal HP
M-Line HP
013017020 to 023024 to 027032 to 037049 to 051075100
1/81/61/51/41/31/23/41