Series 3100 and 3200Industrial Pressure Transmitter
The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current employees as a resource only. They may not be reproduced, published, or transmitted electronically for commercial purposes. Furthermore, the Company’s name, likeness, product names, and logos, included within these compilations may not be used without specific, written prior permission from Dwyer Instruments, Inc.
©Copyright 2011 Dwyer Instruments, Inc
![Page 2: Series 3100 and Series 3200](https://reader038.vdocument.in/reader038/viewer/2022102706/558cdcaed8b42ad0118b4742/html5/thumbnails/2.jpg)
Can be configured with Zero/Span buttons, HART handheld communicator or HART communicator softwareFM and CE approved
FM: Class I, Div I, Group A, B, C and D
High or Low fail safe Output: 4-20mA / HARTAdditional terminals for HART communicator and multimeter. LCD and enclosure can be rotated100:1 TurndownAccuracy: 0.075% F.S.
Features
![Page 3: Series 3100 and Series 3200](https://reader038.vdocument.in/reader038/viewer/2022102706/558cdcaed8b42ad0118b4742/html5/thumbnails/3.jpg)
Enclosure Adjustments
Enclosure can be rotated 360⁰
LCD can be rotated 270⁰
![Page 4: Series 3100 and Series 3200](https://reader038.vdocument.in/reader038/viewer/2022102706/558cdcaed8b42ad0118b4742/html5/thumbnails/4.jpg)
Mechanical Features
3100 comes standard with bleed fittings
Front and back enclosure covers are lockable.
![Page 5: Series 3100 and Series 3200](https://reader038.vdocument.in/reader038/viewer/2022102706/558cdcaed8b42ad0118b4742/html5/thumbnails/5.jpg)
Smart Transmitter
Nonlinearities and temperature dependencies of the pressure sensor are eliminated. Smart
TransmitterConventional Transmitter
![Page 6: Series 3100 and Series 3200](https://reader038.vdocument.in/reader038/viewer/2022102706/558cdcaed8b42ad0118b4742/html5/thumbnails/6.jpg)
HARTThe 3100/3200 transmitters are equipped with analog (4-20mA) and digital (HART) communication.
![Page 7: Series 3100 and Series 3200](https://reader038.vdocument.in/reader038/viewer/2022102706/558cdcaed8b42ad0118b4742/html5/thumbnails/7.jpg)
Push Button ConfigurationThe 3100/3200 can be configured using the Zero/Span buttons The Zero/Span buttons allow the transmitter to be configured without opening the housing covers
![Page 8: Series 3100 and Series 3200](https://reader038.vdocument.in/reader038/viewer/2022102706/558cdcaed8b42ad0118b4742/html5/thumbnails/8.jpg)
Failsafe
The failsafe can be programmed to fail High (21.75mA) or Low (3.75mA) if the self-diagnostic test detects a failure.
![Page 9: Series 3100 and Series 3200](https://reader038.vdocument.in/reader038/viewer/2022102706/558cdcaed8b42ad0118b4742/html5/thumbnails/9.jpg)
Turndown ExplanationExample:
Nominal lower value (LRL) = 0 barNominal upper value (URL) = 100 barLower-range value (LRV) = 0 barUpper-range value (URV) = 1 bar
Turndown:Nominal upper value(URL)/Upper-range value (URV)
100/1 barTD = 100:1
![Page 10: Series 3100 and Series 3200](https://reader038.vdocument.in/reader038/viewer/2022102706/558cdcaed8b42ad0118b4742/html5/thumbnails/10.jpg)
Installation
Steam Service
Liquid Service
Air Service
![Page 11: Series 3100 and Series 3200](https://reader038.vdocument.in/reader038/viewer/2022102706/558cdcaed8b42ad0118b4742/html5/thumbnails/11.jpg)
Calibration Frequency
![Page 12: Series 3100 and Series 3200](https://reader038.vdocument.in/reader038/viewer/2022102706/558cdcaed8b42ad0118b4742/html5/thumbnails/12.jpg)
Calculations
![Page 13: Series 3100 and Series 3200](https://reader038.vdocument.in/reader038/viewer/2022102706/558cdcaed8b42ad0118b4742/html5/thumbnails/13.jpg)
Options
Diaphragm Seals
![Page 14: Series 3100 and Series 3200](https://reader038.vdocument.in/reader038/viewer/2022102706/558cdcaed8b42ad0118b4742/html5/thumbnails/14.jpg)
Options316 SS Housing
![Page 15: Series 3100 and Series 3200](https://reader038.vdocument.in/reader038/viewer/2022102706/558cdcaed8b42ad0118b4742/html5/thumbnails/15.jpg)
3100
Custom Calibration Parameters
Options
![Page 16: Series 3100 and Series 3200](https://reader038.vdocument.in/reader038/viewer/2022102706/558cdcaed8b42ad0118b4742/html5/thumbnails/16.jpg)
Custom Calibration Parameters
3200
Options
![Page 17: Series 3100 and Series 3200](https://reader038.vdocument.in/reader038/viewer/2022102706/558cdcaed8b42ad0118b4742/html5/thumbnails/17.jpg)
AccessoriesBBV Valve Manifolds
2 Valve Manifolds 3 Valve Manifolds5 Valve Manifolds
COM-PC HART Communicator Software
HART Software with all registered DD (Device Description) filesIncludes USB HART Modem
![Page 18: Series 3100 and Series 3200](https://reader038.vdocument.in/reader038/viewer/2022102706/558cdcaed8b42ad0118b4742/html5/thumbnails/18.jpg)
Mounting BracketsA-630 Angle BracketA-631 Flat Bracket
Accessories
![Page 19: Series 3100 and Series 3200](https://reader038.vdocument.in/reader038/viewer/2022102706/558cdcaed8b42ad0118b4742/html5/thumbnails/19.jpg)
Water & Waste Water FacilitiesChemical & Petrochemical PlantsOil & Gas RefineriesPulp & Paper Processing PlantsFood & Beverage PlantsRenewable Energy & Alternative Fuels Soil RemediationIron & Steel FoundriesTest & Measurement Labs
Target Industries
![Page 20: Series 3100 and Series 3200](https://reader038.vdocument.in/reader038/viewer/2022102706/558cdcaed8b42ad0118b4742/html5/thumbnails/20.jpg)
Level ApplicationThe 3100 can be used to monitor the level in a closed or open tank. The transmitter range can be adjusted to compensate for specific gravity.
![Page 21: Series 3100 and Series 3200](https://reader038.vdocument.in/reader038/viewer/2022102706/558cdcaed8b42ad0118b4742/html5/thumbnails/21.jpg)
Gas Train ApplicationThe 3100 is used to monitor the air or air/gas mixture flow into a combustion chamber.
![Page 22: Series 3100 and Series 3200](https://reader038.vdocument.in/reader038/viewer/2022102706/558cdcaed8b42ad0118b4742/html5/thumbnails/22.jpg)
Filter ApplicationsThe 3100 can be used to measure the pressure drop across air filters, liquid filters and reverse osmosis systems in hazardous locations.
![Page 23: Series 3100 and Series 3200](https://reader038.vdocument.in/reader038/viewer/2022102706/558cdcaed8b42ad0118b4742/html5/thumbnails/23.jpg)
Refining Application
The 3100 and 3200 are used to monitor processes converting raw resources to refined natural gas, diesel or gasoline.
![Page 24: Series 3100 and Series 3200](https://reader038.vdocument.in/reader038/viewer/2022102706/558cdcaed8b42ad0118b4742/html5/thumbnails/24.jpg)
Oil Well Application
The 3200 is used to monitor the well pressure to prevent blowouts.
![Page 25: Series 3100 and Series 3200](https://reader038.vdocument.in/reader038/viewer/2022102706/558cdcaed8b42ad0118b4742/html5/thumbnails/25.jpg)
Water Pressure Application
The 3200 is used to monitor the water level in a tower and pump pressure.
![Page 26: Series 3100 and Series 3200](https://reader038.vdocument.in/reader038/viewer/2022102706/558cdcaed8b42ad0118b4742/html5/thumbnails/26.jpg)
Food Processing Application
The 3200 is used to monitor pressure in cooking and processing lines to prevent blockages.
![Page 27: Series 3100 and Series 3200](https://reader038.vdocument.in/reader038/viewer/2022102706/558cdcaed8b42ad0118b4742/html5/thumbnails/27.jpg)
Questions
To order a free catalog or for more information contact;Dwyer Instruments, Inc., P.O. Box 373,
Michigan City, IN., 46361Telephone: (800) 872-9141 or (219) 879-8000
Fax: (219) 872-9057Internet address: www.dwyer-inst.com