Download - SERIES PANEL FLOWMETER
Z-300 SERIES PANEL FLOWMETER
Specication
Dimension Details
Model
Z-3000
Z-3001 206 34 40 215 31 20 165
Z-3002
Z-3003220 41 45 233 47 33 165
Z-3004
Z-3005240 44 50 253 47 33 175
Z-3006
Size (mm)
A B C D E F G
A
D
G
F
E
CB
Z-300
Z-300K SERIES PANEL FLOWMETER
Specication
Dimension Details
Model
K1 K2 K3 168 30 34 176 25 25 127 76
226 45 46 232 48 33 165 100K4 K5
K6 K7
Size (mm)
A B C D E F HG
BC
F
A
D H G
E Z-300k
35
30
25
20
15
10
5
GP
M-L
IQU
ID-S
p.G
r.1.
0-R
EA
D T
OP
OF
FL
OT
0.03~0.35 0.1~1.4 G1/2"
0.2~2 1~7 G1/2"
0.5~5 1.8~18 G1/2"
2~10 8~40 G3/4" ±4%
2~16 6~60 G3/4"
4~24 20~100 G1"
5~35 30~130 G1"
< 0.6MPa
GPM LPM
Measure RangeThread Accuracy Working
PressureModel
Z-3000
Z-3001
Z-3002
Z-3003
Z-3004
Z-3005
Z-3006
Model
K1 0.1~1 0.5~4 ZG1/2"
K2 0.2~2 1~7 ZG1/2"
K3 0.5~5 2~18 ZG1/2"
K4 1~10 5~35 ZG1" ±4%
K5 2~14 10~50 ZG1"
K6 2~20 10~70 ZG1"
K7 5~35 10~130 ZG1"
< 0.6MPa
GPM LPM
Measure RangeThread Accuracy Working
Pressure
Z-300 SERIES
PANEL FLOWMETER
1
Z-300 T SERIES PANEL FLOWMETER
Dimension Details
Model
10T 168 30 34 176 25 25 127 76
20T 226 45 46 232 48 33 165 100
25T 226 45 46 232 48 33 165 100
Size (mm)
A B C D E F HG
DH G A
F
C B
0.5
1.0
1.5
2.0
2.5
3.0
3.5
E
10T/20T/25T
Specication
oWater 20 C
10T
20T
25T
Measure Range
Air(L/min)LPMGPM
Thread Accuracy WorkingPressure
0.1~1
0.2~2
0.5~5
0.5~4
1~7
2~18
16~120
30~300
60~600
male
ZG1/2"
±7% <0.6MPa
male
ZG1"
male
ZG3/4"150~1000
300~1500
300~2100
900~400030~130
Model
10~70
10~50
5~351~10
2~14
2~20
5~35
Z-300 T SERIES
PANEL FLOWMETER
2
Z-500 SERIES PANEL FLOWMETER
Z-50 – – –0 8 C S P H
Model
Float MaterialS - ABSC - 304SS
Measure range
ConnectionP - Pin-board pipeM - Male threadF - Female threadE - Elbow
Specication
FemaleThread
MaleThread
Pipe
Connection
Z-5008
ModelMeasure Range
Z-5008C
Z-5015
Z-5025
Z-5032
Z-5050
0.1~1
0.2~2
0.5~5
0.1~1
0.2~2
0.5~5
0.25~2.5
0.5-5
0.8-8
0.8-8
1-10
1.2~12
2-20
2.5-25
2.5-25
5-45
7-70 25-250
20-180
10-100
10-100
8-80
5-50
4-40
3-30
3~30
1.8~18
1~10
1.8~18
1~7
0.5~4
1.8~18
1~7
0.5~4
ø20
ø20
ø20
ø32
ø40
ø63 2"NPT
1" NPT
3/4"NPT
ZG3/4"
1/2" NPT
1/2" NPT
1/2" NPT
1/2" NPT
3/4" NPT
1" NPT
2"NPT
(GPM) (LPM)
Z-500 SERIES
PANEL FLOWMETER
3
Z-500 SERIES PIPELINE FLOWMETER (VIEW)
P
DL
1
L
B1
B2
L2
M
dL
3
d
L4
D
F E
b
F W
Pin-Board Pie Male Thread
L2
1/2"3/4"
170 ø13
225 252 25 56.5 ø13
210 205 25 56.5 ø13
250 3/4" 225 270 25 83 ø20
312 1½" 290 325 31 95 ø25
400 2" 370 440 40 120 ø45
2½"
Model L Dd
1/2"
1/2"
3/4"
1½"
2"
2½"89
73
49
39
26
26
26
B2B1
20
20
20
32
40
63
75420
375
290
230
180
208
150
L1
42
50
50
59
72
100
120
100
160
134
170
225
290
325
Z-5008
Z-5008C
Z-5015
Z-5025
Z-5032
Z-5050
Z-5065
Female Thread
d L3 L4 E F b
Elbow (W)
Z-500 SERIES
PIPELINE FLOWMETER
4
LZS SERIES PIPELINE FLOWMETER
Specication
Dimension Details
DN : 15-65
L
B1
B2
B3
0.004-0.04
0.006-0.06
0.01-0.1
15 LZS-150.016-0.16 1/2"NPT
G1/2"0.025-0.25
203/4"NPT
0.04-0.4
0.06-0.6
0.1-1
0.1-1
25 LZS-25 0.16-1.6 32 3/7"NPT G3/7"
0.25-2.5
0.4-432 LZS-32 40 1"NPT G1"
0.6-6
0.4-4
0.6-650 LZS-50
1-1063 2"NPT G2'
1.6-16
5-2565 LZS-65 8-40 75 G2½"
12-60
10014-90LZS-100
ange 18-120
12518-120LZS-125
ange 25-180
18-100
150 25-150LZS-150ange
25-180
DN(mm) Model
Measure rangem3/h
MetricUnion
MaleThread
FemaleThread
Sizes(mm)DN(mm)
L B1 B2 B3
15
25
32
50
65
100
125
150
220
230
290
350
420
547
547
547
20
32
40
63
Distance of center hole 175 mm
Distance of center hole 175 mm
Distance of center hole 175 mm
26
39
49
73
88
51
60
72
98
122
Max. working pressure Working temperature Accuracy
: 0.6MPa0: 0-60 C
: ±5%
LZS SERIES
PIPELINE FLOWMETER
5
FLX SERIES PIPELINE FLOWMETER
Specication
0.005-0.05
0.01-0.1
15 FLX-15
0.016-0.16
G1/2"0.025-0.25
200.04-0.4
0.06-0.6
0.1-1
0.1-1
25 FLX-25 0.16-1.6 32 G3/7"
0.25-2.5
0.4-432 FLX-32 40 G1"
0.6-6
0.4-4
0.6-650 FLX-50
1-1063 G2'
1.6-16
5-2565 FLX-65 8-40 75 G2½"
12-60
10014-90FLX-100
ange 18-120
12518-120FLX-125
ange 25-180
18-100
150 25-150FLX-150ange
25-180
DN(mm) Model
Measure rangem3/h
MetricUnion
FemaleThread
Max. working pressure Working temperature Accuracy
: 0.6MPa0
: 0-60 C: ±4%
FLX SERIES
PIPELINE FLOWMETER
FLX 15~FLX 65
1- Joint pipe
5- Scale 6- Taper tube 7- Float 8- Stop plate (down)
2- Screw cap 3- O-ring 4- Stop plate (up)
Model
FLX 15
FLX 25
FLX 32
FLX 50
180 230 56 27 ɸ13 G1/2’’
G3/4’’
G1’’
G2’’
ɸ20
ɸ26
ɸ45
28
35
40
70.5
86
109
295
425
460
205
319
325
L L4 F G A H
Dimension Details - With Elbow
Dimension Details - Without Elbow
Model
FLX 15
FLX 20
FLX 25
FLX 32
FLX 40
FLX 65
FLX100
FLX125
FLX150
FLX 50
220 180 44 26 20
ɸ14*4
25
32
40
50
63
75
31
40
49
60
73
82
51
57
74
87
98
123
189Flange
connection
188
205
319
321
325
360
N.A
230
255
368
380
395
446
555
L H D1 D2 D3
D
F
L4
L
G
H
a
6
FLXP SERIES PIPELINE FLOWMETER
Specication
0.005-0.05
0.01-0.1
15FLXP-15
0.016-0.16
G1/2"0.025-0.25
200.04-0.4
0.06-0.6
0.1-1
0.1-1
25 FLXP-25 0.16-1.6 32 G3/7"
0.25-2.5
0.4-432 FLXP-32 40 G1"
0.6-6
0.4-4
0.6-650 FLXP-50
1-1063 G2'
1.6-16
5-2565 FLXP-65 8-40 75 G2½"
12-60
10014-90FLXP-100
ange 18-120
12518-120FLXP-125
ange 25-180
18-100
150 25-150FLXP-150
ange25-180
DN(mm) Model
Measure rangem3/h
MetricUnion
FemaleThread
Max. working pressure Working temperature Accuracy
: 0.6MPa0
: 0-60 C: ±4%
FLXP SERIES
PIPELINE FLOWMETER
FLXP 15~FLX 65
1- Joint pipe
5- Scale 6- Taper tube 7- Float 8- Stop plate (down)
2- Screw cap 3- O-ring 4- Stop plate (up)
Model
FLXP 15
FLXP 25
FLXP 32
FLXP 50
160 220 56 27 ɸ13 G1/2’’
G3/4’’
G1’’
G2’’
ɸ20
ɸ26
ɸ45
28
35
40
70.5
86
109
270
345
440
170
225
290
L L4 F G A H
Dimension Details - With Elbow
Dimension Details - Without Elbow
Model
FLXP 15
FLXP 25
FLXP 32
FLXP 65
FLXP100
FLXP125
FLXP150
FLXP 50
241 180 56 27 20
ɸ14*4
32
40
63
75
28
35
40
82
70.5
86
109
123
189Flange
connection
205
319
325
360
N.A
295
430
495-
555
L H D1 D2 D3
D
F
L4
L
G
H
a
6
Performance Feature
Diameter : DN10mm-DN2000mm Electrode : 316L, Hc, Ti, Ta, Pt Liner : Rubber, polyurethane, PTFE, PFA, F46 Medium : Electric conductivity liquids Medium Conductivity : 5µ s/cm Accuracy : ±0.5% RS- ±1.0% RS Velocity of ow : 0.1m/s-10m/s
0 0 0 Working Temperature : Compact 120 C,remote 150 C (rubber 80 C) Working Pressure : 0.6MPa-4.0MPa (based on diameter) Protection Class : IP65, IP67 Related Converter type : NX710 / NX720 / NX730 Output : 4-20mA / Frequency / pulse output signal Power Supply : 220VAC / 24VDC, battery Installation Type : Compact, remote
FE SeriesIntelligent Electromagnetic Flowmeter Sensors
FE External Dimension (mm)
NX 700 SERIES
ELECTROMAGNETIC FLOWMETER
KE SeriesElectromagnetic Flowmeter Sensors (Tri-clover type)
CE SeriesElectromagnetic Flowmeter Sensors (Clamp type)
TE SeriesElectromagnetic Flowmeter Sensors (Thread type)
7
NX 710 SeriesIntelligent Electromagnetic Flowmeter Converters
NX 720 SeriesIntelligent Electromagnetic Flowmeter Converters
NX 730 SeriesIntelligent Electromagnetic Flowmeter Converters
Performance Feature
Output : 4-20mA, pulse / frequency output (passive) Accuracy : ±0.5%, ±1% Power supply : 220VAC / 24VDC Measure direction : Forward / reverse
0 0 Environmental condition : Temp. -25 C-60 C, relative humidity 90% Power-off protection : 10 years Display : 7 numbers of instantaneous delivery, 8 numbers of totalizer Computed mode : 4 keys Volumes : 132* 132* 95mm Installation type : Compact
Performance Feature
Output : 4-20mA, pulse / frequency output (passive) Accuracy : ±0.5%, ±1% Power supply : 220VAC / 24VDC Measure direction : Forward / reverse
0 0 Environmental condition : Temp. -25 C-60 C, relative humidity 90% Power-off protection : 10 years Display : 7 numbers of instantaneous delivery, 8 numbers of totalizer Communication : RS485 or HART protocol Computed mode : 3 keys Volumes : 181.5* 171* 141mm Installation type : Compact
Performance Feature
Output : 4-20mA, pulse / frequency output (passive) Accuracy : ±0.25%, ±0.5% Power supply : 220VAC / 24VDC Measure direction : Forward / reverse
0 0 Environmental condition : Temp. -25 C-60 C, relative humidity 90% Power-off protection : 10 years Display : 7 numbers of instantaneous delivery, 7 numbers of totalizer Communication : RS485 or HART protocol Computed mode : 4 keys Volumes : 180* 120* 75mm Installation type : Remote
NX 700 SERIES
ELECTROMAGNETIC FLOWMETER
8
Flow Range Chart by pipe Size
NX 700 SERIES
ELECTROMAGNETIC FLOWMETER
9
FE Series Electromagnetic Flowmeter Sensors
Dimension Details for Compact and Remote Type
10 150 90 60 130
132.5
137.5
145
162.5
172.5
187.5
202.5
220
270
302.5
407.5
460
517.5
572.5
622.5
675
745
892
1002.5
1102.5
1397.5
1610
1810
2017.5
2227.5
6 4
4
6
7
12
14
15
18
29
36
6
8
9
11
13
15
16
27
33
70 70
102 100
121
145
207
210
250
350
460
550
123
147
212
229
252
352
462
558
780
1250
1550
2080
2600
785
1258
65
75
85
100
110
125
145
210
240
95
105
115
140
150
165
185
250
285
150
150
150
150
150
200
200
250
300
400
500
500
600
600
600
600
700
800
900 1115
1340
1560
1760
1970
2180
1405
1630
1830
2045
2265
1015
895
780
670
615
565
505
445
395 350
400
460
515
565
620
725
840
950
1050
15
4.0
1.6
1.0
0.6
20
25
32
40
50
65
125
150
250
300
350
400
450
500
600
700
800
900
1200 1200
1400 1400
1600 1600
1800 1800
2000 2000
4-ø14
4-ø14
4-ø14
4-ø14
4-ø18
4-ø18
4-ø18
8-ø18
8-ø18
8-ø22
12-ø22
12-ø22
16-ø22
16-ø26
20-ø26
20-ø26
20-ø30
24-ø30
24-ø33
28-ø33
32-ø33
36-ø36
40-ø36
44-ø39
48-ø42
DNmm
Workingpressure
MPa
Compactweight(Kg)
Remoteweight(Kg)
Lmm
Dmm
Kmm
H n-øA
20
25
19
23
160
180
690 680
200
220
200
250
80
100
8-ø18
8-ø18
4951350 340 295200 8-ø22
1175 11201000 1000 28-ø301182.5
352.5
230
NX 700 SERIES
ELECTROMAGNETIC FLOWMETER
10
NX 700E Series battery powered electromagnetic owmeters have special designed sensor and high-powered lithium battery with embedded micro processor. It can measure ow in both direction, and display ow rate and totalized ow. Features include GSM / GPRS remote transmitting, data logging, data analysis, etc.
NX 700E SERIES
BATTERY POWERED ELECTROMAGNETIC FLOWMETER
Performance Feature
Diameter : DN25mm-DN600mm Electrode : 316L, Hb, Hc, Ti, Ta, Pt Liner : Rubber, PTFE Medium : Conductivity liquids Medium Conductivity : 5µ s/cm, softener water 20µ s/cm Accuracy : ±1% RS- ±1.5% RS Velocity of ow : 0.3m/s-5m/s
0 Working Temperature : Compact 120 C Working Pressure : 0.6MPa-4.0MPa (base on diameter) Protection Class : IP65, IP67 Optional Converter type : NX800 / NX810 / NX820 Output Signal : Passive pulse (only for factory ow test) Power Supply : Battery Installation Type : Compact, remote
NX 800
NX 810 with GPRS
NX 820
Battery Powered Electromagnetic Converters
Accuracy : ±1% RS to ±2% RS Measure Direction : Forward / reverse
0 0 Environment Condition : Temperature -10 C~ +60 C, relative humidity 90% Display : 6 Numbers of instantaneous delivery, 10 numbers of totalizer Dimensions : 120 x120 x 240mm Installation : Compact Power Supply : 3.6V lithium battery (4PCS/set)
11
Specication
NX 800 SERIES
VARIABLE-AREA FLOWMETER
LZ METALLIC TUBE SERIES VARIABLE-AREA FLOWMETER
Product Description
NX 800 series metallic rotameter is a variable-area owmeter with simple structure, easy mounting arrangement and with high precision It is reliable and has wide application eld for variety of liquids & gases.
NX 800 DX series metallic rotameter comes with LCD and 4-20mA output. Compared with other owmeters this series can withstand higher remperature & pressure. It is easy to read. It is suitable for chemical industry, petroleum, metallurgy, power plant, environmental protection, medical science etc.
Principle of operation
As the uid ow upward in the tube, the oat moves upward to a position where the lifting force and the gravitational force are balanced. At that moment the circulation area between the oat and the orice is kept xed. The circulation area is proportional to the height of the oat which means that the height of the oat represents the volumetric ow rate. When the ow moves up and down, it transmits its position to the indicator outside in form of magnetic-coupling, which makes the needle of the indicator follows the movement of oat.
Measure Range
Water (L/h) 3Air (Nm /h)Normal Type Corrosion-proof type
Pressure Loss (KPa)
Orice Plate Cone Pipe
Water WaterAir Air
2.5~25 - - 0.07~0.7 5.5 7.1 2.1 2.6
4.0~40 2.5~25 0.11~1.1 5.5 7.2 2.1 2.6
6.3~63 4.0~40 0.18~1.8 5.5 7.3 2.1 2.6
1510~100 6.3~63 0.28~2.8 5.6 7.5 2.1 2.6
16~160 10~100 0.48~4.8 5.6 8.0 2.1 2.6
25~250 16~160 0.7~7.0 5.8 10.8 2.1 2.6
40~400 25~250 1.0~10.0 6.1 10.0 2.1 2.8
63~630 40~400 1.6~16.0 7.3 14.0 2.2 3.2
63~630 40~400 1.6~16 5.7 7.2 2.4 3.2
100~1000 63~630 3~30 5.9 7.7 2.4 3.3
25 160~1600 100~1000 4.5~45 6.0 8.8 2.5 3.4
250~2500 160~1600 7~70 6.8 12.0 2.6 3.8
400~4000 250~2500 11~110 9.2 19.0 3.0 4.5
630~6300 400~4000 18~180 6.8 8.6 3.3 7.4
50 1000~10000 630~6300 25~250 9.4 10.4 3.8 7.7
1600~16000 1000~10000 40~400 14.5 15.5 4.3 8.4
2500~25000 1600~16000 70~700 6.9 12.9 3.6 6.880
4000~40000 2500~25000 100~1000 8.0 18.5 4.6 8.9
6300~63000 4000~40000 160~1600 8.5 19.2 5.8 12.0100
10000~100000 6300~63000 250~2500 8.8 19.6 6.4 12.8
125 12000~120000 300~3000 9.0 20.3 7.0 13.5
150 15000~150000 400~4000 9.2 20.8 7.1 13.8
DN(mm)
12
Features
High accuracy digital paddlewheel technology Flow rate and total ow display Easy to read with large digital LCD display Low pressure drop Corrosion resistant PVDF sensor Minimum maintenance required Long - life lithium battery Totalizer : can be reset and history can be kept User set security password
Item
Velocity range
Diameter
Wetted material
Seal ring
Working temperature
Working pressure
Paddlewheel ow sensor
0.3~6m/s
DN10-DN50 (with PVDF triplet)
DN65-500 (insert type)
Sensor : PVDF
Impeller : PVDF
Shaft lever : ceramics
Viton,EPDM0PVDF : -20~+140 C
1.0MPa, 0.8Mpa
Item
Model
Accuracy
Repeatability
Temperature
External dimension
Installation method
Power supply
Output signal
Communication
Alarm
Protection class
Consumption
Flow Convertor
NX 510
± ±1.5%1%,
±0.5%0- +65 C20~
4~20mA, Passive pulse
100x100mm
Panel mount, compact type (DN10~DN50)
DC24V, battery power supply, AC220V
Upper limit, lower limit, totalizer
IP65
2W
RS485
Specication
1. Turbine Flowmeter Sensor (Thread type)
NX 510 SERIES
PADDLEWHEEL FLOWMETER
Range / Specication
DN(mm)
10 G3/8’’ 152 121
130
142
141
175
175
152
158
158
168
184
1.0
0.8
G1/2’’
G3/4’’
G1’’
G2’’
G1½’’
15
20
25
40
50
MalePress(MPa)
Amm
Bmm
Temp.0( C)
Range3(m /h)
0.1~1.8
0.2~4
0.3~6
0.5~12
0.5~24
2~40
0<80 C
PVDF PaddlewheelFlow Converter
Paddlewheel Flowmeter
NX 510 series owmeter is based on velocity & uid. It is good for low viscous liquids & gives high accuracy ow rate & ow totalizer.
13
Range / Specication
DN(mm)
10 G3/8’’ 152 121
130
142
141
175
175
152
158
158
168
184
1.0
0.8
G1/2’’
G3/4’’
G1’’
G2’’
G1½’’
15
20
25
40
50
MalePress(MPa)
Amm
Bmm
Temp.0( C)
Range3(m /h)
0.1~1.8
0.2~4
0.3~6
0.5~12
0.5~24
2~40
0<80 C
2. Wafer Type Specication
2. Wafer Type Flowmeter
3. Flange Type 4. Glue Type
50
65
80
100
125
200
250
150
12-Ø22
8-Ø18
4-Ø184~40 124
145
160
180
210
240
295
350
6~60
10~100
15~150
20~200
40~400
60~600
100~1000
0<80 C0.8<
DN(mm)Press(MPa)C N-ØA
Temp.0( C)
Range3(m /h)
Application
Water treatment systems Process treatment / distribution Irrigation system Filtration system Swimming pool and hot spring Groundwater packing Counter ow monitor Ultra-pure water delivery Desalination Zero discharge system Process cooling water
NX 510 SERIES
TURBINE FLOWMETER
NX 510
G3/8’’, G3/4’’, G1½’’
Page 15
14