Transcript
Page 1: Slide 1 of 30 Ranger Discoverer Operations Guide ELearning Module Ver. 3.14

Slide 1 of 30

Ranger Discoverer Operations GuideELearning Module Ver. 3.14

Page 2: Slide 1 of 30 Ranger Discoverer Operations Guide ELearning Module Ver. 3.14

Slide 2 of 30 Taking a Single Shot SurveyOperational Walkthrough

TAKING A SINGLE-SHOT SURVEY

1. Turn on the Ranger Controller by pressing the ‘Power’ button.

2. Align the Infra-red window of the RC boot with the window of the

RDI, ensuring that there is a direct line-of-sight between the two.

3. Select the green ‘Connect To Tool’ button on

the left hand side of the screen.

4. A sequence of communication messages will be displayed while the

RC and the RDI synchronize. Progress is shown in a green bar

along the bottom of the screen.

NOTE: At this point we will assume you have read Chapter 7 from the RANGER Discoverer Operator Manual.

.

Page 3: Slide 1 of 30 Ranger Discoverer Operations Guide ELearning Module Ver. 3.14

Slide 3 of 30 Taking a Single Shot SurveyOperational Walkthrough

5. Scroll the icons located on the bottom of the Main

Menu screen to the left or right until the Single Shot

icon is located and tap it once. The icon will

become centralized and will expand.

6. Make sure the Infra-red windows are still aligned

for communications, tap the icon once and wait for

the next screen.

WARNING: HARD KNOCKS RESULT IN

COSTLY REPLACEMENT.TAKE CARE WHEN HANDLING THERANGER SURVEY INSTRUMENT.

Page 4: Slide 1 of 30 Ranger Discoverer Operations Guide ELearning Module Ver. 3.14

Slide 4 of 30 Taking a Single Shot SurveyOperational Walkthrough

8. Select the green ‘Take Shot’ button located in the top left corner of the screen. NOTE: If the

button is greyed out, it means the RC is busy. Wait until the button is green before continuing.

7. When the Single Shot survey screen is displayed, the RC can be removed from the RDI. Assemble

the RDI into suitable Ranger Running Gear and lower into the hole to the start point of the survey.

NOTE: When the system is in position for the first survey point, ensure adequate time is allowed for the RDI to settle .

# Description

1 38mm Spacer Bar (1.2m)

2 38mm IrDA Top Sub

3 38mm Bottom Sub

4 38mm Brass Barrel

5 Ranger Discoverer Instrument

6 38mm Bottom Sub Shock Assembly

7 Landing Collar (Spear Type)

8 Landing Collar (Box Type)

Page 5: Slide 1 of 30 Ranger Discoverer Operations Guide ELearning Module Ver. 3.14

Slide 5 of 30 Taking a Single Shot SurveyOperational Walkthrough

9. Once you have pressed the button for the

first time, the date and time of the recorded shot will

be displayed in one of the three available windows

at the bottom of the screen. Two more shots will be

available for recording and will also be displayed at

the bottom of the screen.

10. Once satisfied with the recorded survey points, retrieve the RDI and disassemble the survey tool

from the running gear. Ensure that the RDI and the RC Infra-red windows are correctly aligned

before pressing the ‘Finish & Download’ button.

All recorded surveys will be downloaded to the controller for analysis.

NOTE: A maximum of three shots are available when in Single Shot Mode.

Page 6: Slide 1 of 30 Ranger Discoverer Operations Guide ELearning Module Ver. 3.14

Slide 6 of 30 Taking a Single Shot SurveyOperational Walkthrough

11. Once the download is complete, the RC will

automatically open the View Survey screen. Tap the

‘+’ tab on the right of the screen to view the survey

data.

12. Press the ‘Return’ button to exit to the Main Menu.

EXPORTING SURVEYS FROM RC TO FLASH DRIVE

1. If already connected to the RDI, to view a survey select the button in the main menu screen. Otherwise select the button from the Ranger Start Screen.

2. Select surveys that are to be copied (to the USB stick) by clicking on the individual check boxes or select the ‘SELECT ALL’ box. This option allows you to select all the surveys in the RC without selecting them one by one.

3. Once the required surveys are selected press the ‘COPY TO FLASH’ button.

4. The transfer of files is completed when this message box appears. Press OK. The USB Flash Drive can now be removed.

To transfer the data to a USB mass memory device (also shown in more detail later in this course) :

Page 7: Slide 1 of 30 Ranger Discoverer Operations Guide ELearning Module Ver. 3.14

Slide 7 of 30 Taking a Multi Shot SurveyOperational Walkthrough

TAKING A MULTI-SHOT SURVEY

1. If it’s not already on, turn on the RC (Ranger Controller) by

pressing the green ‘Power’ button.

2. Align the Infra-red window of the RC boot with the window of the

RDI, ensuring that there is a direct line-of-sight between the two.

3. Using the Stylus, tap the green ‘Connect to Tool’

button on the left hand side of the Start Screen, or

navigate the light blue selection box over the button using the

keypad arrows and press the ‘Enter’ key.

Page 8: Slide 1 of 30 Ranger Discoverer Operations Guide ELearning Module Ver. 3.14

Slide 8 of 30 Taking a Multi Shot SurveyOperational Walkthrough

5. Using the stylus or the keypad, scroll through the icons at the

bottom of the Main Menu screen. Select the Multi-Shot icon and

either tap the enlarged icon again or press the ‘Enter’ key.

4. A sequence of communication messages will be displayed while

the RC and the RDI synchronize. Progress is shown in a green

bar along the bottom of the screen.

NOTE: To scroll using the stylus, flick the icons either to the left or right.

Page 9: Slide 1 of 30 Ranger Discoverer Operations Guide ELearning Module Ver. 3.14

Slide 9 of 30 Taking a Multi Shot SurveyOperational Walkthrough

NOTE: It is now time to assemble the RDI into the configured Running Gear, suitable to be attached directly onto the Core Barrel Inner Tube Assembly after removing the Core Lifter Case. Once dry released into the drilling fluid and assembly has located in the core barrel Outer Assembly, surveying can commence at the bottom of the hole during each rod removal from the drill string.

6. A list of messages will be shown while communications are established between the RC and RDI.

Ranger Multi-Shot Running Gear

# Description

1 38mm Spacer Bar (1.2m)

2 HQ Inner Tube Box to E‒Pin Sub

3 38mm IrDA Top Sub

4 38mm Brass Barrel

5 Ranger Discoverer Instrument

6 38mm Bottom Sub

7 38mm Bottom Sub Shock Assembly

Page 10: Slide 1 of 30 Ranger Discoverer Operations Guide ELearning Module Ver. 3.14

Slide 10 of 30 Taking a Multi Shot SurveyOperational Walkthrough

7. Once the Create Survey screen is displayed, you are ready to create

a survey.

8. Select whether the survey is an ‘IN RUN’

(Surveying while entering the hole) or an ‘OUT RUN’

(Surveying while being withdrawn from the hole).

9. Enter the correct details for ‘SURVEY’, ‘SURVEYOR’, ‘LOCATION’,

‘START DEPTH’ and ‘DEPTH INT’ by selecting the textbox you want

to edit and pressing the keyboard activation button. As

changes are made, the textbox color will change from light blue to

gold. To hide the keyboard, press the keyboard activation button

again.

NOTE: “START DEPTH” and “DEPTH INT” values must be strictly numeric with a maximum of one decimal point. Previous survey details will be set as the default values for new surveys.

Page 11: Slide 1 of 30 Ranger Discoverer Operations Guide ELearning Module Ver. 3.14

Slide 11 of 30 Taking a Multi Shot SurveyOperational Walkthrough

10. Once the data is finalized, press the ‘Create Survey’ button.

11. Once the Take Shot screen is displayed, you are ready to take the

first shot.

12. When the RDI is in position for surveying, select the ‘Take Shot’

button.

The ‘Recording’ button replaces the ‘Take Shot’ button until the

data of that particular survey point is successfully recorded.

Once the shot has been recorded, the disabled button replaces

the original button until the RDI is ready to take a new shot.

NOTE: The RDI must be kept still while taking a survey reading.

Page 12: Slide 1 of 30 Ranger Discoverer Operations Guide ELearning Module Ver. 3.14

Slide 12 of 30 Taking a Multi Shot SurveyOperational Walkthrough

13. Once the RDI has completed taking a survey shot, the ‘DEPTH’

will change to indicate the depth of the next survey point. The

‘DEPTH’ value is directly proportional to the ‘DEPTH INTERVAL’

value, which can be changed between surveys.

14. During the surveying of a hole, the ‘DEPTH’ and ‘DEPTH

INTERVAL’ can be changed between each survey point by

selecting the desired textbox, followed by the keyboard icon and

then entering the new values.

Page 13: Slide 1 of 30 Ranger Discoverer Operations Guide ELearning Module Ver. 3.14

Slide 13 of 30 Taking a Multi Shot SurveyOperational Walkthrough

15. Once the survey point has been recorded, move the RDI to the next depth interval and repeat

steps 12 to 14 as necessary.

16. When surveying is completed, disassemble the survey tool from the running gear and re-establish

the link between the RDI and RC using the Infra-red window. Ensure there is direct line-of-sight

between the RC and the RDI, before selecting the ‘Finish & Download’ button.

NOTE: The current survey can be stopped and a new one started by selecting the ‘Finish & Start New’ button.

All previous surveys including the current one are then available for download using the ‘Finish & Download’

button.

Page 14: Slide 1 of 30 Ranger Discoverer Operations Guide ELearning Module Ver. 3.14

Slide 14 of 30 Taking a Multi Shot SurveyOperational Walkthrough

17. When the Downloading Data screen is displayed, a sequence of

communication messages will appear while the survey data is

downloaded. Progress is shown as a green bar along the bottom.

18. Once the download has successfully completed, the screen will

automatically change to the Main Menu screen where the ‘View

Surveys’ icon can be selected to view all the downloaded

surveys, including the latest survey.

WARNING: To preserve the battery life of the RDI download your survey immediately after retrieving the RDI from the drill hole. Once the download is complete the RDI will go into low battery mode thus preserving the battery life.

WARNING: Data may be lost if surveys are not downloaded and the RDI battery is left to discharge. If a new battery is not connected within 5 minutes of removing the flat battery, the RDI’s residual energy will be drained and data will be lost.

Page 15: Slide 1 of 30 Ranger Discoverer Operations Guide ELearning Module Ver. 3.14

Slide 15 of 30 Viewing a Survey on the RCOperational Walkthrough

VIEWING A SURVEY ON THE RC

1. If already connected to the RDI, to view a survey select the ‘View

Surveys’ button from the Main Menu screen.

Otherwise, select the ‘View Existing Surveys’ button from the

Ranger Start screen.

NOTE: The RDI does not need to be synchronized with the RC to view surveys.

NOTE: The last survey that has been taken is displayed first in the list as item #1.If a large number or surveys are listed, scrolling is possible by flicking the list in the up or down direction.

2. A list of surveys will be displayed including the survey name, date,

and time. Select the required survey from the list of surveys.

Page 16: Slide 1 of 30 Ranger Discoverer Operations Guide ELearning Module Ver. 3.14

Slide 16 of 30 Viewing a Survey on the RCOperational Walkthrough

3. Press the expansion button on the right hand side of the survey

item to view the location of the survey. Once the item is expanded,

press the button to collapse the item again.

4. Once the correct survey has been selected, press the ‘Load

Survey’ button to view the data of each survey shot.

5. A scrolling list of all the shots taken for the selected survey will be

displayed.

Page 17: Slide 1 of 30 Ranger Discoverer Operations Guide ELearning Module Ver. 3.14

Slide 17 of 30 Viewing a Survey on the RCOperational Walkthrough

6. Press the expansion button on the right hand side of the survey point.

The survey point will expand and display all relevant shot data. To view

gauge interpretations of the data, flick the table format to the left. Once

expanded press the button to minimize.

Page 18: Slide 1 of 30 Ranger Discoverer Operations Guide ELearning Module Ver. 3.14

Slide 18 of 30 Viewing a Survey on the RCOperational Walkthrough

7. Survey points can be scrolled up or down

the screen depending on how many

surveys and survey shots there are, even

when in expanded mode. If the survey

shots roll of the screen, they can be viewed

by flicking the scroll in the up or down

direction.

8. While viewing the survey data, the

‘SURVEY NAME’, ‘TOOL ID’ and the ‘# of

SHOTS’ can be also viewed and confirmed

at the top of the screen.

Page 19: Slide 1 of 30 Ranger Discoverer Operations Guide ELearning Module Ver. 3.14

Slide 19 of 30 Viewing a Survey on the RCOperational Walkthrough

9. The expanded survey data also displays the battery

status of the RDI when the shot was taken.

A green battery indicates that the RDI battery

is in good condition, as shown in the image on the right.

A red battery indicates that the battery life of the

RDI is close to, or has already reached, its minimum

capacity for correct operation, and as a result survey

readings may be inaccurate.

At this stage replacement of the depleted battery with a

fully charged RDI battery pack is recommended.

WARNING: Data may be lost if surveys are not downloaded and the RDI battery is left to discharge. Also, if a new battery is not connected within 5 minutes of removing the flat battery, the RDI’s residual energy will be drained and data will be lost.

Page 20: Slide 1 of 30 Ranger Discoverer Operations Guide ELearning Module Ver. 3.14

Slide 20 of 30 Exporting Surveys from the RC to a Flash DriveOperational Walkthrough

EXPORTING SURVEYS FROM RC TO FLASH DRIVE

1. If already connected to the RDI, to view a survey select the

‘View Surveys’ button from the Main Menu screen.

Otherwise select the button from the Ranger Start screen.

2. Select the surveys that are to be copied (to the USB stick) by

clicking on the individual check boxes, or by checking the

‘SELECT ALL’ box. This option allows you to select all the

surveys in the RC without selecting them one by one.

Page 21: Slide 1 of 30 Ranger Discoverer Operations Guide ELearning Module Ver. 3.14

Slide 21 of 30 Exporting Surveys from the RC to a Flash DriveOperational Walkthrough

3. Once the required surveys are selected, press the ‘Copy

To Flash’ button.

4. The transfer of files is completed when the ‘SUCCESS’

message box appears.

5. Press the ‘OK’ button.

The USB Flash Drive can now be removed.

Page 22: Slide 1 of 30 Ranger Discoverer Operations Guide ELearning Module Ver. 3.14

Slide 22 of 30 Exporting Surveys from a Flash Drive to PCOperational Walkthrough

EXPORTING FILES FROM FLASH DRIVE TO PC

1. Insert the Flash Drive into a free USB slot on your PC.

2. A connection sound will be heard and the AutoPlay tab

should be seen on the bottom Windows toolbar.

3. Open the AutoPlay tab and select ‘Open folder to view

files’.

Page 23: Slide 1 of 30 Ranger Discoverer Operations Guide ELearning Module Ver. 3.14

Slide 23 of 30 Exporting Surveys from a Flash Drive to PCOperational Walkthrough

4. Open the ‘RANGER’ folder…

…followed by the ‘DATA’ folder.

Page 24: Slide 1 of 30 Ranger Discoverer Operations Guide ELearning Module Ver. 3.14

Slide 24 of 30 Exporting Surveys from a Flash Drive to PCOperational Walkthrough

5. Open the folder representing the Tool ID number of the RDI that the survey was taken with, followed by opening the “Downloaded” folder.

6. Single shot surveys are distinguished by the date and time that the

survey was taken. While Multi-shot surveys are distinguished by their names as well as by the time and date of the taken survey.

Each survey will have both a CSV and XML file format. The CSV file can be opened

using Microsoft Excel to view survey results, while the XML format is needed when importing the survey data into the RANGER SAS software for further survey

analysis.

7. To view survey data in excel format, double click the survey file with the correct CSV extension at the end of it. This will automatically open Microsoft Excel and display the survey data.

Page 25: Slide 1 of 30 Ranger Discoverer Operations Guide ELearning Module Ver. 3.14

Slide 25 of 30 USB Error MessagesTroubleshooting

1. Attempting to copy a survey from the RC to a Flash

Drive without the Flash Drive being connected to the

RC.

Make sure that the USB stick provided with the RC

has been inserted into the correct slot (USB host) at

the bottom of the RC boot, as shown to the right.

During the transfer of files from the RC to the Flash Drive (USB STICK), a number of error messages may appear if correct conditions are not met during the file transfer process. These error messages will be triggered with the following actions:

Page 26: Slide 1 of 30 Ranger Discoverer Operations Guide ELearning Module Ver. 3.14

Slide 26 of 30 USB Error MessagesTroubleshooting

2. Attempting to copy a survey file from the RC to the USB

Flash Drive when a file with the same name already

exists on the flash drive.

The message box will inform you that a survey file with

the same name already exists. It will then ask whether

you wish to overwrite the existing file with the new

survey file by selecting YES or to leave the original one

by selecting NO.

During the transfer of files from the RC to the Flash Drive (USB STICK), a number of error messages may appear if correct conditions are not met during the file transfer process. These error messages will be triggered with the following actions:

Page 27: Slide 1 of 30 Ranger Discoverer Operations Guide ELearning Module Ver. 3.14

Slide 27 of 30 Ranger Survey Running GearVital Points to be Aware of

VITAL POINTS TO BE AWARE OF:

1. BRASS BARREL HAS IDENTICAL THREADS AT EITHER END TO ENABLE IT TO BE

REVERSED; THIS OPTIMISES ITS WORKING LIFE.

2. Only use minimal amounts of a petroleum jelly or O-ring grease on O-rings and threads.

3. Do not use pipe wrenches on brass barrel joints.

4. O-rings have a dual function. In addition to their retaining action, they seal the barrel from ingress

of drilling fluid. Continually check O-ring condition.

5. Always use correct barrel size for your specific drilling conditions. If you’re in doubt about size to

use contact your RANGER distributor.

Page 28: Slide 1 of 30 Ranger Discoverer Operations Guide ELearning Module Ver. 3.14

Slide 28 of 30 Ranger Survey Running GearNOMENCLATURE

ITEM DESCRIPTION1 Dry Release Sleeve2 Survey Overshot3 Spear Sub4 Swivel5 Aluminium Spacer Bar6 Landing Collar – Pin/Spear 7 Landing Collar – Box 8 Inner Tube Box to E Pin Sub9 Top Sub Assembly

10 Brass Survey Barrel11 Bottom Sub and Shock Assembly12 Orientation Bull Plug Assembly13 Orientation Mule Shoe Assembly

Page 29: Slide 1 of 30 Ranger Discoverer Operations Guide ELearning Module Ver. 3.14

Slide 29 of 30 Ranger Survey Running GearNOMENCLATURE

Ranger Single-Shot Running Gear

# Description

1 38mm Spacer Bar (1.2m)

2 38mm IrDA Top Sub

3 38mm Bottom Sub

4 38mm Brass Barrel

5 Ranger Discoverer Instrument

6 38mm Bottom Sub Shock Assembly

7 Landing Collar (Spear Type)

8 Landing Collar (Box Type)

Page 30: Slide 1 of 30 Ranger Discoverer Operations Guide ELearning Module Ver. 3.14

Slide 30 of 30 Ranger Survey Running GearNOMENCLATURE

Ranger Multi-Shot Running Gear

# Description

1 38mm Spacer Bar (1.2m)

2 HQ Inner Tube Box to E‒Pin Sub

3 38mm IrDA Top Sub

4 38mm Brass Barrel

5 Ranger Discoverer Instrument

6 38mm Bottom Sub

7 38mm Bottom Sub Shock Assembly

Page 31: Slide 1 of 30 Ranger Discoverer Operations Guide ELearning Module Ver. 3.14

Slide 31 of 30

Ranger Discoverer Operations GuideELearning Module Ver. 3.14


Top Related