![Page 1: Soil Testing Data Logger Mid-Semester Presentation February 22, 2011](https://reader035.vdocument.in/reader035/viewer/2022062809/5697c00f1a28abf838cca41e/html5/thumbnails/1.jpg)
Soil Testing Data LoggerMid-Semester Presentation
February 22, 2011
![Page 2: Soil Testing Data Logger Mid-Semester Presentation February 22, 2011](https://reader035.vdocument.in/reader035/viewer/2022062809/5697c00f1a28abf838cca41e/html5/thumbnails/2.jpg)
Team Members
Cody Griffin
Op Am CircuitryVDIP CommunicationHardware TestingNormal Mode Design
Electrical Engineering
Daniel Herrington
Software Design LeadVDIP CommunicationSoftware TestingWebsite Design
Electrical Engineering
Ashley Stockbridge
RTCC Software DesignSetup Mode DesignNormal Mode DesignSoftware Testing
Electrical Engineering
Matt Weissinger
PCB DesignOp Amp CircuitryHardware TestingComponent Research
Electrical Engineering
![Page 3: Soil Testing Data Logger Mid-Semester Presentation February 22, 2011](https://reader035.vdocument.in/reader035/viewer/2022062809/5697c00f1a28abf838cca41e/html5/thumbnails/3.jpg)
Outline
• Background• Problem• Solution• Constraints
– Technical– Practical
• Progress and Refinements• Packaging• Testing Plan• Production
![Page 4: Soil Testing Data Logger Mid-Semester Presentation February 22, 2011](https://reader035.vdocument.in/reader035/viewer/2022062809/5697c00f1a28abf838cca41e/html5/thumbnails/4.jpg)
Background – Soil Redox Potential
• Electrical property of soil that correlates to the specific chemicals present in the ground
• Research topic of Dr. Kroger with the Forest and Wildlife Research Center at MSU
![Page 5: Soil Testing Data Logger Mid-Semester Presentation February 22, 2011](https://reader035.vdocument.in/reader035/viewer/2022062809/5697c00f1a28abf838cca41e/html5/thumbnails/5.jpg)
Problem – Chemical Runoff
• Caused by fertilizers and pesticides used on farmlands
• Can be controlled using a detailed historical set of soil redox data
• No efficient method for collecting soil redox measurements
![Page 6: Soil Testing Data Logger Mid-Semester Presentation February 22, 2011](https://reader035.vdocument.in/reader035/viewer/2022062809/5697c00f1a28abf838cca41e/html5/thumbnails/6.jpg)
Solution – Soil Testing Data Logger
• Reduces the time associated with taking soil redox potential measurements in the field
• Periodically takes soil redox potential and associated temperature measurements
• Stores all measurements in a removable USB storage device
![Page 7: Soil Testing Data Logger Mid-Semester Presentation February 22, 2011](https://reader035.vdocument.in/reader035/viewer/2022062809/5697c00f1a28abf838cca41e/html5/thumbnails/7.jpg)
Technical Constraints
Constraint Description
Inputs The device must support four soil probe inputs and five temperature inputs.
Soil Redox Potential Input Range
The device must be able to measure potentials that range from -600mV to +600mV with an accuracy of ±10mV.
Temperature Indicator Input Range
The device must be able to measure temperatures that range from -40°C to 125°C with an accuracy of ±1°C.
Data Storage The device must store soil redox potential and temperature data on a removable USB storage device.
Sample Rate The device must store sample data every 20 minutes.
![Page 8: Soil Testing Data Logger Mid-Semester Presentation February 22, 2011](https://reader035.vdocument.in/reader035/viewer/2022062809/5697c00f1a28abf838cca41e/html5/thumbnails/8.jpg)
Practical Constraints
Type Constraint Description
Manufacturability Size The size of the circuit board must be no larger than 3.1” x 3.9”.
Environmental Operating Conditions The device must be able to operate in extreme weather conditions.
![Page 9: Soil Testing Data Logger Mid-Semester Presentation February 22, 2011](https://reader035.vdocument.in/reader035/viewer/2022062809/5697c00f1a28abf838cca41e/html5/thumbnails/9.jpg)
Manufacturability
• No larger than 3.1” x 3.9”• Easily accessible for routine maintenance• Organized for easy assembly
![Page 10: Soil Testing Data Logger Mid-Semester Presentation February 22, 2011](https://reader035.vdocument.in/reader035/viewer/2022062809/5697c00f1a28abf838cca41e/html5/thumbnails/10.jpg)
Environmental
Cleveland, MS
![Page 11: Soil Testing Data Logger Mid-Semester Presentation February 22, 2011](https://reader035.vdocument.in/reader035/viewer/2022062809/5697c00f1a28abf838cca41e/html5/thumbnails/11.jpg)
Progress and Refinements
• PCB Refinements– Added third RJ45 connection– Added programming header– Minor silkscreen changes
• Manufactured initial set of soil probes• Added software start-up delay• Conducted initial laboratory testing
![Page 12: Soil Testing Data Logger Mid-Semester Presentation February 22, 2011](https://reader035.vdocument.in/reader035/viewer/2022062809/5697c00f1a28abf838cca41e/html5/thumbnails/12.jpg)
PCB Refinements
• Allows for grouping of soil/temp probe pairs• Lowers difficulty of manufacturing soil/temp probes
![Page 13: Soil Testing Data Logger Mid-Semester Presentation February 22, 2011](https://reader035.vdocument.in/reader035/viewer/2022062809/5697c00f1a28abf838cca41e/html5/thumbnails/13.jpg)
Manufactured Soil / Temp Probes
• Soil / Temp probes are waterproofed using:– RJ45 cables– Heat shrink– Water tight sealant
![Page 14: Soil Testing Data Logger Mid-Semester Presentation February 22, 2011](https://reader035.vdocument.in/reader035/viewer/2022062809/5697c00f1a28abf838cca41e/html5/thumbnails/14.jpg)
Packaging
• PCB is final packaging for data logger• Soil and temperature probes will be
manufactured by the team
![Page 15: Soil Testing Data Logger Mid-Semester Presentation February 22, 2011](https://reader035.vdocument.in/reader035/viewer/2022062809/5697c00f1a28abf838cca41e/html5/thumbnails/15.jpg)
Testing Plan
• Completed:– Short Term Laboratory Test– Short Term Field Test
• In Progress:– Long Term Field Test
![Page 16: Soil Testing Data Logger Mid-Semester Presentation February 22, 2011](https://reader035.vdocument.in/reader035/viewer/2022062809/5697c00f1a28abf838cca41e/html5/thumbnails/16.jpg)
Temperature Testing Data
![Page 17: Soil Testing Data Logger Mid-Semester Presentation February 22, 2011](https://reader035.vdocument.in/reader035/viewer/2022062809/5697c00f1a28abf838cca41e/html5/thumbnails/17.jpg)
Soil Redox Probe Testing Data
![Page 18: Soil Testing Data Logger Mid-Semester Presentation February 22, 2011](https://reader035.vdocument.in/reader035/viewer/2022062809/5697c00f1a28abf838cca41e/html5/thumbnails/18.jpg)
Production
• After changes to PCB have been finalized, new PCB will be fabricated and populated
• Additional data loggers and soil / temp probes will be manufactured at Dr. Kroger’s request
![Page 19: Soil Testing Data Logger Mid-Semester Presentation February 22, 2011](https://reader035.vdocument.in/reader035/viewer/2022062809/5697c00f1a28abf838cca41e/html5/thumbnails/19.jpg)
References
[1] “Season Weather Averages for Mid Delta Regional,” Weather Underground. 2010. http://www.wunderground.com/NORMS/DisplayNORMS.asp?AirportCode=KGLH&SafeCityName=Cleveland&StateCode=MS&Units=none&IATA=GLH
![Page 20: Soil Testing Data Logger Mid-Semester Presentation February 22, 2011](https://reader035.vdocument.in/reader035/viewer/2022062809/5697c00f1a28abf838cca41e/html5/thumbnails/20.jpg)
Questions?Questions?