![Page 1: Solid phase extraction & cold vapor atomic absorption spectrometry](https://reader036.vdocument.in/reader036/viewer/2022062503/587127711a28abe4448b66f5/html5/thumbnails/1.jpg)
1
In the name of God
![Page 2: Solid phase extraction & cold vapor atomic absorption spectrometry](https://reader036.vdocument.in/reader036/viewer/2022062503/587127711a28abe4448b66f5/html5/thumbnails/2.jpg)
Solid phase extraction & cold vapor atomic absorption spectrometry
December 2014
2
![Page 3: Solid phase extraction & cold vapor atomic absorption spectrometry](https://reader036.vdocument.in/reader036/viewer/2022062503/587127711a28abe4448b66f5/html5/thumbnails/3.jpg)
3
Introduction & background
Methods
Application
Outline
Conclusion
![Page 4: Solid phase extraction & cold vapor atomic absorption spectrometry](https://reader036.vdocument.in/reader036/viewer/2022062503/587127711a28abe4448b66f5/html5/thumbnails/4.jpg)
IntroductionSolid phase extraction is the very popular technique currently available for rapid and selective sample preparation. The versatility of SPE allows use of this technique for many purposes, such as purification, trace enrichment, desalting, and class fractionation and etc.
4
![Page 5: Solid phase extraction & cold vapor atomic absorption spectrometry](https://reader036.vdocument.in/reader036/viewer/2022062503/587127711a28abe4448b66f5/html5/thumbnails/5.jpg)
5
SPE procedure
![Page 6: Solid phase extraction & cold vapor atomic absorption spectrometry](https://reader036.vdocument.in/reader036/viewer/2022062503/587127711a28abe4448b66f5/html5/thumbnails/6.jpg)
The formats in SPE
•Free disks
•Cartridge
•96-well plates
6
![Page 7: Solid phase extraction & cold vapor atomic absorption spectrometry](https://reader036.vdocument.in/reader036/viewer/2022062503/587127711a28abe4448b66f5/html5/thumbnails/7.jpg)
Cartridges
The SPE cartridge is a small plastic or glass open-ended container filled with adsorptive particles of various types and adsorption characteristics.
7
![Page 8: Solid phase extraction & cold vapor atomic absorption spectrometry](https://reader036.vdocument.in/reader036/viewer/2022062503/587127711a28abe4448b66f5/html5/thumbnails/8.jpg)
DiscsDiscs consist of a 0.5 mm thick membrane where the adsorbent is immobilized in a web of microfibrils.The sorbent (on polymer or silica) is embedded in a web of PTFE or glass fibre.
8
![Page 9: Solid phase extraction & cold vapor atomic absorption spectrometry](https://reader036.vdocument.in/reader036/viewer/2022062503/587127711a28abe4448b66f5/html5/thumbnails/9.jpg)
96-well plates
The new format of SPE is 96-Well SPE Plates.Parallel sample processing allows 96 samples to be extracted in approximately one hour or less.
9
![Page 10: Solid phase extraction & cold vapor atomic absorption spectrometry](https://reader036.vdocument.in/reader036/viewer/2022062503/587127711a28abe4448b66f5/html5/thumbnails/10.jpg)
Advantage for SPE
Solid phase extraction has been widely used in the separation and preconcentration of various species. There are many advantages to this technique, such as simplicity, reliability, reduction in analysis time, reduction or elimination of the use of organic solvents and a high potential for automation.
10
![Page 11: Solid phase extraction & cold vapor atomic absorption spectrometry](https://reader036.vdocument.in/reader036/viewer/2022062503/587127711a28abe4448b66f5/html5/thumbnails/11.jpg)
Atomic absorption spectrometry
11
![Page 12: Solid phase extraction & cold vapor atomic absorption spectrometry](https://reader036.vdocument.in/reader036/viewer/2022062503/587127711a28abe4448b66f5/html5/thumbnails/12.jpg)
12
CV-AAS
![Page 13: Solid phase extraction & cold vapor atomic absorption spectrometry](https://reader036.vdocument.in/reader036/viewer/2022062503/587127711a28abe4448b66f5/html5/thumbnails/13.jpg)
Paper1: A new method for preconcentration and determination of mercury in fish, shellfish and saliva by CV-AAS
1. separation and preconcentration of mercury
2. measurement of mercury was performed in CV-AAS
13
![Page 14: Solid phase extraction & cold vapor atomic absorption spectrometry](https://reader036.vdocument.in/reader036/viewer/2022062503/587127711a28abe4448b66f5/html5/thumbnails/14.jpg)
Sample preparations for the determination of mercury in human saliva
1. Samples were collected from healthy volunteers aged 20-25 years. 2. 2 ml of sample was transferred to teflon cup of acid digestion bomb
3. HN(65% w/v, 4 ml) and (30% v/v, 1ml) were added.
4. The digestion bomb flask was placed in an oven at c for 6 h.5. Cooling and adjusting the pH with a NaOH solution
6. The digest was transferred to a 100 ml volumetric flask containing 20 ml of buffer solution
7. Finally, the flask was filled to volume with ultrapure water.
14
![Page 15: Solid phase extraction & cold vapor atomic absorption spectrometry](https://reader036.vdocument.in/reader036/viewer/2022062503/587127711a28abe4448b66f5/html5/thumbnails/15.jpg)
Sample preparations for the determination of mercury in fish, shellfish:
1. 0.1 g of sample was weighed
2. Transferred to teflon cups in order to microwave the acid digestion bombs.
3. 2.0 ml of 65% (w/v) HN and 1.0 ml of ultrapure water were added.
4. The system subjected to microwave radiation for 60 s at a power of 100 w.
5. Cooling and adjusting the pH with a NaOH solution
6. The digest was transferred to a 100 ml flask containing 20 ml of buffer solution.
7. Finally, the flask was filled to volume with ultrapure water.
15
![Page 16: Solid phase extraction & cold vapor atomic absorption spectrometry](https://reader036.vdocument.in/reader036/viewer/2022062503/587127711a28abe4448b66f5/html5/thumbnails/16.jpg)
Optimization of conditions for the preconcentration
A 1.0 µg Hg (II) solution was used in the optimization of variables. The extraction of the element by XAD-BTAC was calculated using the following equation: E = (CV/) x 100, where C is the concentration of mercury in the eluent, V is the volume of the eluent, is the initial concentration of mercury in the solution passed through the minicolumn, and is the volume of the mercury solution that was passed through the minicolumn.
16
![Page 17: Solid phase extraction & cold vapor atomic absorption spectrometry](https://reader036.vdocument.in/reader036/viewer/2022062503/587127711a28abe4448b66f5/html5/thumbnails/17.jpg)
Effect of pHpH plays an important role in the ligand–metal interaction
17
![Page 18: Solid phase extraction & cold vapor atomic absorption spectrometry](https://reader036.vdocument.in/reader036/viewer/2022062503/587127711a28abe4448b66f5/html5/thumbnails/18.jpg)
Effect of concentration of eluent
18
1.75 mol concentration of HCl was chosen
![Page 19: Solid phase extraction & cold vapor atomic absorption spectrometry](https://reader036.vdocument.in/reader036/viewer/2022062503/587127711a28abe4448b66f5/html5/thumbnails/19.jpg)
Effect of flow rate of eluent
• The effect of the flow of eluent was examined in the range from 1.0 to 8.1 mL
• Employing flow values between 5.5 and 8.1 mL , no significant variation on response was observed.
the value of 6.6 ml for the flow of the
eluent was chosen.
19
![Page 20: Solid phase extraction & cold vapor atomic absorption spectrometry](https://reader036.vdocument.in/reader036/viewer/2022062503/587127711a28abe4448b66f5/html5/thumbnails/20.jpg)
Sample flow rate
●The sorption of Hg (II) on functionalized resin was studied at flow rates varying from 1.0 to 10.1 ml
● The best results were obtained when the flow rates were from 1.0 to 6.6 mL.
● A flow of 5.5 ml was established to provide a high sampling rate without compromising retention of hg (II).
20
![Page 21: Solid phase extraction & cold vapor atomic absorption spectrometry](https://reader036.vdocument.in/reader036/viewer/2022062503/587127711a28abe4448b66f5/html5/thumbnails/21.jpg)
Results for determination of mercury in certified reference material and saliva samples.
21
![Page 22: Solid phase extraction & cold vapor atomic absorption spectrometry](https://reader036.vdocument.in/reader036/viewer/2022062503/587127711a28abe4448b66f5/html5/thumbnails/22.jpg)
22
Results for determination of mercury in seafood samples using the proposed procedure.
![Page 23: Solid phase extraction & cold vapor atomic absorption spectrometry](https://reader036.vdocument.in/reader036/viewer/2022062503/587127711a28abe4448b66f5/html5/thumbnails/23.jpg)
Characteristics of methods using solid phase extraction for preconcentration of mercury
23
LOD: limit of detection; EF: enrichment factor; PDCA: 2,6-pyridine dicarboxylic acid; AATP: 2-aminoacetylthiophenol; 1,2-BAE: 1,2-bis(o-minophenylthio)ethane; PSDVB: polystyrene–divinylbenzene; ACPG: aminopropyl-controlled pore glass; PSTH: 1,5-bis(2 pyridyl)-3-sulphophenyl methylene thiocarbonohydrazyde; DPTH: 1,5-bis(di-2-pyridyl)methylene thiocarbohydrazide; TS: methylthiosalicylate; BG: Brilliant Green; MB: 2-mercaptobenzimidazole; TC: thiosemicarbazide
![Page 24: Solid phase extraction & cold vapor atomic absorption spectrometry](https://reader036.vdocument.in/reader036/viewer/2022062503/587127711a28abe4448b66f5/html5/thumbnails/24.jpg)
Amberlite XAD-4 (polystyrene–divinylbenzene) resin
24
![Page 25: Solid phase extraction & cold vapor atomic absorption spectrometry](https://reader036.vdocument.in/reader036/viewer/2022062503/587127711a28abe4448b66f5/html5/thumbnails/25.jpg)
BTAC: 2-(2-benzothiazolylazo)-p-cresol
Molecular formula: OS
Systematic name: 2-[(E)-1,3-Benzothiazol-2-yldiazenyl]-4-methylphenol
25
![Page 26: Solid phase extraction & cold vapor atomic absorption spectrometry](https://reader036.vdocument.in/reader036/viewer/2022062503/587127711a28abe4448b66f5/html5/thumbnails/26.jpg)
Conclusion• The proposed method for the determination of mercury proved to be
simple, efficient and easy to perform in the matrices analysed.
• The Amberlite XAD-4 functionalized with BTAC reagent, which was efficient for the complexation of Hg (II) allowing extraction/preconcentration with a high enrichment factor.
• The proposed procedure also presented analytical features (e.g., limit of detection, precision and accuracy) suitable for the determination of Hg(II) in both saliva samples and in fish and shellfish.
26
![Page 27: Solid phase extraction & cold vapor atomic absorption spectrometry](https://reader036.vdocument.in/reader036/viewer/2022062503/587127711a28abe4448b66f5/html5/thumbnails/27.jpg)
SPE of ultra traces mercury (II) using octadecyl silica membrane disks modified by 1,3-bis(2-ethoxyphenyl)triazene (EPT) ligand and determination by CV-AAS
• pH=3.5
• Amount of ligand=7.5 mg
• Eluent= use 1.5 M perchloric acid solution
• Flow rate= 3 mL for the eluent and 50 mL for the sample
27
![Page 28: Solid phase extraction & cold vapor atomic absorption spectrometry](https://reader036.vdocument.in/reader036/viewer/2022062503/587127711a28abe4448b66f5/html5/thumbnails/28.jpg)
Chemical structure of 1,3-di(2-ethoxyphenyl) triazene (EPT).
28
![Page 29: Solid phase extraction & cold vapor atomic absorption spectrometry](https://reader036.vdocument.in/reader036/viewer/2022062503/587127711a28abe4448b66f5/html5/thumbnails/29.jpg)
Determination of Hg(ǁ) ions in 500 ml of real samples after applying recommended procedure.
29
![Page 30: Solid phase extraction & cold vapor atomic absorption spectrometry](https://reader036.vdocument.in/reader036/viewer/2022062503/587127711a28abe4448b66f5/html5/thumbnails/30.jpg)
Comparing the performance of this method with other methods for determination of ions.
30
![Page 31: Solid phase extraction & cold vapor atomic absorption spectrometry](https://reader036.vdocument.in/reader036/viewer/2022062503/587127711a28abe4448b66f5/html5/thumbnails/31.jpg)
SPE of Cd on 2-mercaptobenzothiazole loaded on sulfur powder in the medium of ionic liquid 1-butyl-3-methylimidazolium hexafluorophosphate and CVG-AAS determination
• pH=8.5 using either 0.1 mol HN & NaOH solutions
• parameters using either 2.5 ml of 2 mol of HCl
• flow rate a flow rate of 8 mL was selected for the
eluent and 12 mL for the sample
• sample volume the maximum sample volume is 200mL 31
![Page 32: Solid phase extraction & cold vapor atomic absorption spectrometry](https://reader036.vdocument.in/reader036/viewer/2022062503/587127711a28abe4448b66f5/html5/thumbnails/32.jpg)
Chemical structure of ligands:
32
1-butyl-3-methylimidazolium hexafluorophosphate
2-mercaptobenzothiazole
![Page 33: Solid phase extraction & cold vapor atomic absorption spectrometry](https://reader036.vdocument.in/reader036/viewer/2022062503/587127711a28abe4448b66f5/html5/thumbnails/33.jpg)
Determination of cadmium in water samples
33
![Page 34: Solid phase extraction & cold vapor atomic absorption spectrometry](https://reader036.vdocument.in/reader036/viewer/2022062503/587127711a28abe4448b66f5/html5/thumbnails/34.jpg)
Determination of cadmium in fish samples
34
![Page 35: Solid phase extraction & cold vapor atomic absorption spectrometry](https://reader036.vdocument.in/reader036/viewer/2022062503/587127711a28abe4448b66f5/html5/thumbnails/35.jpg)
Comparison of papers
sample element sample flow rate
adsorbent
pH
paper1 Water & fish
mercury 6 ml Agar modified
2.5
paper2 Water & fish
mercury 4 ml Dowex
OptiporeV-493
2
paper3 Water & fish
mercury 16 ml sulfur 8.5
35
![Page 36: Solid phase extraction & cold vapor atomic absorption spectrometry](https://reader036.vdocument.in/reader036/viewer/2022062503/587127711a28abe4448b66f5/html5/thumbnails/36.jpg)
Comparison of papers
ligand eluent solution DL
Linear rang
paper12-mercaptobenzimidazole
HCl 0.2ng
0.04-2.4ng
paper2S. aureus HCl __ __
paper3 N-(2-chlorobenzoyl)-N-phenylthiourea
HCl __ __
36
![Page 37: Solid phase extraction & cold vapor atomic absorption spectrometry](https://reader036.vdocument.in/reader036/viewer/2022062503/587127711a28abe4448b66f5/html5/thumbnails/37.jpg)
Structure of ligands
37
N-(2-chlorobenzoyl)-N-phenylthiourea 2-mercaptobenzimidazole
![Page 38: Solid phase extraction & cold vapor atomic absorption spectrometry](https://reader036.vdocument.in/reader036/viewer/2022062503/587127711a28abe4448b66f5/html5/thumbnails/38.jpg)
Refrences:
• V. A. Lemos, L. O. dos Santos, 2014, Food Chemistry., 149, 203–207.
• M. K. Rofouei, A. Sabouri, A. Ahmadalinezhad, H. Ferdowsi, 2011, Journal of Hazardous Materials., 192, 1358–1363.
• N. Pourreza, K. Ghanemi, 2010, Journal of Hazardous Materials., 178, 566–571.
• N. Pourreza, H. Parham, A. R. Kiasat, K. Ghanemi, N. Abdollahi, 2009, Talanta., 78, 1293–1297.
38
![Page 39: Solid phase extraction & cold vapor atomic absorption spectrometry](https://reader036.vdocument.in/reader036/viewer/2022062503/587127711a28abe4448b66f5/html5/thumbnails/39.jpg)
• N. Pourreza, K.Ghanemi, 2009, Journal of Hazardous Materials., 161, 982–987.
• M. Tuzen, I. Karaman, D. Citak, M. Soylak, 2009, Food and Chemical Toxicology., 47, 1648–1652.
• A. Żwir-Ferenc, M. Biziuk, 2006, Polish J. of Environ. Stud., 15, 677-690.
• www.mercury-instrumentsusa.com
• www.sigmaaldrich.com
39
![Page 40: Solid phase extraction & cold vapor atomic absorption spectrometry](https://reader036.vdocument.in/reader036/viewer/2022062503/587127711a28abe4448b66f5/html5/thumbnails/40.jpg)
40
THANK YOU
![Page 41: Solid phase extraction & cold vapor atomic absorption spectrometry](https://reader036.vdocument.in/reader036/viewer/2022062503/587127711a28abe4448b66f5/html5/thumbnails/41.jpg)
41
Any question?
No?!!!
Thank YOU!!!